HomeMy WebLinkAboutB17-0282_M002_1507064533.pdfSPIROVENT AIR NO SCALE BOILER PIPING SCHEMATIC P-2 4"Ø PVC P-4 IWH-1 4"Ø CPVC OR CODE P-3 SEPARATOR FLUID POWER ENERGY MODEL 2012 3-WAY THERMOSTATIC VALVE APPROVED PVC VENT, TYP. EXPANSION TANK (ET-1) SEE PLBG. CLOSE COUPLE MAX. 6" SEPARATION SUPPLY AND RETURNS TO SNOWMELT AND RADIANT FLOOR HEAT LOOP. SEQUENCE THESE ITEMS IN ORDER SHOWN. INSULATE ALL PIPING PER 2012 I.E.C.C.REQUIREMENTS. SIZE ALL BALANCING VALVES TO 12" MIN. 60" MAX. WATER PRESSURE DROP. NOTE: 1. 2. 3. PUMP SHALL CYCLE ON THRU RELAY FROM END SWITCHES IN MANIFOLDS P-6 PROVIDE DOMESTIC WATER HEATING PRIORITY CALL TO BOILER & SHUT OFF P1 CONCENTRIC VENT KIT THRU WALL, TYP (E)BOILER (N)B-1 GAS CA, TYP. 6" MAX., TYP. TYP. FIRST FLOOR BASEMENT SECOND FLOOR THIRD FLOOR (E)BOILER P-1 SNOWMELT MANIFOLD #3 SNOWMELT MANIFOLD #2 SNOWMELT MANIFOLD #4 SNOWMELT MANIFOLD #5 SNOWMELT MANIFOLD #6 SNOWMELT MANIFOLD #7 SNOWMELT MANIFOLD #8 SNOWMELT MANIFOLD #9 PRV MAKE-UP WATER AV GF-1 ET-1 P-5 (E)CIRC PUMP (E)CIRC PUMP SNOWMELT MANIFOLD #1 RADIANT MANIFOLD #2 RADIANT MANIFOLD #8 RADIANT MANIFOLD #1 RADIANT MANIFOLD #3 RADIANT MANIFOLD #4 RADIANT MANIFOLD #5 RADIANT MANIFOLD #6 RADIANT MANIFOLD #7 RADIANT MANIFOLD #9 RADIANT MANIFOLD #10 RADIANT MANIFOLD #11 2" 2-1/2" 2-1/2" 2" 2" 1-1/4" 2" 3/4" 1-1/2" 1-1/2" 1" 2" 3/4" HX-1: TRIANGLE TUBE TTP3-40 OWNER PROJECT NO.: 21074.00 VAIL, COLORADO 81657 311 BRIDGE STREET LANDSCAPE SHERRY DORWARD P.O. BOX 3766 VAIL, CO 81658 ARCHITECT ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT. STUITE 117 DENVER, CO 80216 HILL BUILDING RENOVATION 39°38'24"N 106°22'25"W STRUCTURAL MONROE NEWELL 70 BENCHMARK RD. SUITE 204 AVON, CO 81620 ENGINEER MEP DMCE ENGINEERING 5737 6TH AVE. LAKEWOOD, CO 80214 ENGINEER CIVIL ALPINE ENGINEERING, INC. 34510 HIGHWAY 6 UNIT A-9 EDWARDS, CO 81632 ENGINEER TOWN OF VAIL USE ISS.# DESCRIPTION DATE S BUILDING PERMIT ISSUE 2017-07-07 01 BUILDING DEPT COMM. 2017-08-16 1 02 PERMIT REVISIONS 2017-08-25 2 03 FOR CONSTRUCTION 2017-09-01 3 M001 MECHANICAL COVER SHEET S SPECIFIED MANUFACTURER / MODEL NECESSARILY USED ON THIS PROJECT. NOTE: NOT ALL VALVES ON THIS LIST ARE DESCRIPTION SYMBOL EQUALS BY LEGEND SPECIFICATION LIST BALL VALVE AUTO FLOW CONTROL VALVE CHECK VALVE GAS COCK STRAINER MILWAUKEE / 105 or 115 MILWAUKEE / CL 223 or CL 323 MILWAUKEE / BA 100 H FLOWSET / AV POTTROFF / VFD-10 TRERICE / 600C METRAFLEX / METRASPHERE EPDM FLOWSET / YR KEYSTONE / SERIES 500 AMTROL 705 WATTS / SERIES 40, 140, 240, or 340 BY T.C. CONTRACTOR AMBER-BOOTH / 2600 EPDM NIBCO NIBCO STOCKHAM MILLIKEN CENTERLINE - ASHCROFT / MAG PETERSON / PETE's PLUG - - KEYSTONE RED & WHITE - - - - - NIBCO DEZURIK - GERAND APOLLO BURKET BARCO KECKLEY KECKLEY ASHCROFT / MA CONBRACO CONBRACO - UNIVERSAL / 45PT-N NIBCO - - - - - NIBCO GRISWOLD STOCKHAM - - MASON / MFNC EPDM WEKSLER / EA14 WEKSLER / AA5H - RED & WHITE RED & WHITE - - - - NIBCO - - - - SKINNER GERAND TEMPERING VALVE LEONARD LAWLER VENTURI REDUCED PRESSURE MANUAL AIR VENT AUTOMATIC AIR VENT FLEXIBLE PIPE CONNECTION THERMOMETER PRESSURE GAUGE SMOKE DAMPER PRESSURE/TEMP. RELIEF P-T TAP STRAINER W/ BLOWOFF VALVE FIRE DAMPER FIRE & SMOKE DAMPER BOILER DRAIN VALVE FLOWSET / SUPERSEAL MILWAUKEE / 105 or 115 MILWAUKEE / 590T or 1590T MILWAUKEE / 509T, 1590T, F2974(M)(A), 548, or 1400 SERIES - MILWAUKEE / BA-100 or BA-150 WATTS / ACV 115 FLOWSET / ACCUSETTER ASCO / RED HAT BY T.C. CONTRACTOR WATTS / SERIES 77S with B-6081 VALVE MAXITROL / BV37 or BV64 WATTS / 909QTS POTTROFF / FSD-142 POTTROFF / SD-142 WATTS / B-3000 or B-3001 for 1/2" - 3" FLOWSET / VW WATTS / SERIES 77S for 1/2" thru 2-1/2" TRERICE / BX91403 1/2 HOFFMAN FLOWSET A PRESSURE REDUCING VALVE BALANCING VALVE GATE VALVE BACKFLOW PREVENTOR SOLENOID VALVE WAFER BALANCE VALVE BUTTERFLY VALVE STOP/DRAIN VALVE GATE VALVE IN GROUND BOX GLOBE VALVE TEMP. CONTROL - 2-WAY TEMP. CONTROL - 3-WAY PLUG VALVE - GAS PRESSURE REGULATOR - -SCHLUMBERGER / VARIES - -AIR ADMITTANCE VALVE STUDOR VENT NIBCO STOCKHAM BALL DRAIN W/ HOSE END CONNECTIONAPOLLO / 78-103-1 1/2" N.P.T. BY HOSE ABBREV. DESCRIPTION ABBREV. DESCRIPTION SYMBOL SYMBOL DESCRIPTION ABBREV. S SYMBOL U.C. SIZE H 20/16 M B W H S MECHANICAL LEGEND BUTTERFLY VALVE PIPE DOWN PIPE TEE DOWN SAND OIL WASTE GREASE WASTE STORM PIPE GATE VALVE BALANCING VALVE BALL VALVE COLD WATER HOT WATER HOT WATER RECIRCULATE VENT PIPE WASTE PIPE AUTO FLOW CONTROL VALVE GLOBE VALVE STOP & DRAIN VALVE CHECK VALVE NITROGEN CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION REFRIGERANT HOT GAS HIGH PRESSURE STEAM LOW PRESSURE STEAM HIGH PRESSURE STEAM RETURN LOW PRESSURE STEAM RETURN HEATING WATER SUPPLY PIPE UP ST OD SO DHW DHC FIRE W V AIR HPSR LPS CWS CWR CHS CHR RH RS RL VAC VACUUM AIR FIRE DCW LPR HWS HWR HPS A HEATING WATER RETURN CONDENSER WATER SUPPLY CONDENSER WATER RETURN CHILLED WATER SUPPLY PLUG VALVE MANUAL DAMPER W/ LOCKING FLEXIBLE DUCT CONNECTOR VACUUM BREAKER THERMOMETER FIRE & SMOKE DAMPER SMOKE DAMPER EXISTING FIRE DAMPER RETURN GRILLE CONNECTION NEW TO EXISTING. FLEXIBLE PIPE CONNECTION DOOR UNDERCUT FIRE DAMPER 45° DUCT TAKE-OFF PRESSURE GAUGE FLOW SENSOR DUCT SIZE INDICATING SHEET METAL DIMENSIONS. FIRST NUMBER WIDTH & SECOND IS DEPTH. DUCT ELBOW W/ TURNING VANE MOTORIZED DAMPER QUADRANT. CFM DIFFUSER I.D. DEMO ITEM LINE WEIGHT NECESSARILY USED ON THIS PROJECT. } NOTE: NOT ALL SYMBOLS ON THIS LEGEND ARE FLEX DIFFUSER NECK SIZE DUCT TEE W/ TURNING VANES EXISTING ITEM LINE WEIGHT NEW ITEM LINE WEIGHTS # x # x #Ø FLEX SIZE F.D. BRK F.S. F.S. CO CO R.D. VTR O.R.D. H B W H P# BOILER DRAIN VALVE SMOKE DETECTOR PIPE ANCHOR VENT THRU ROOF FLOOR DRAIN WALL HYDRANT DOWNSPOUT NOZZLE HOSE BIBB AIR VENT P-T TAP PIPE GUIDE (SLEEVE) PIPE EXPANSION JOINT PRESSURE/TEMP. RELIEF PUMP PRESSURE REDUCING VALVE SOLENOID VALVE MOTORIZED GATE VALVE REDUCED PRESSURE BACKFLOW PREVENTOR WAFER BALANCE VALVE VENTURI UNION PIPE REDUCER STRAINER STRAINER W/ BLOWOFF VALVE EQUIPMENT ROOM DRAIN FLOOR SINK - HALF GRATE FLOOR SINK - 1/4 GRATE DRAIN ABOVE ROOF DRAIN CLEANOUT - VERTICAL CLEANOUT - HORIZONTAL ROOF DRAIN - OVERFLOW PIPE CAP BREAK - MISC. GAS COCK TEMP. CONTROL - 2-WAY TEMP. CONTROL - 3-WAY 3-WAY VALVE SPIN-IN FITTING W/ DAMPER RIGID DUCT (N) NEW (E) (R) EXISTING RELOCATED GAS PRESSURE REGULATOR ACCESS DOOR IN CEILING CWS CWR CHS CHR RS RL RH HWS HWR HPS HPSR LPS LPSR N VAC A N F W V GAS PIPE GAS OD SO G ST PIPE TEE UP GAS COCK (SHUT-OFF) AND UNION FS BALL DRAIN W/ HOSE END CONNECTION. REMOTE SENSOR CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR THERMOSTAT T S CD CM HUMIDISTAT H M *NOTE: ALL DASHED PLUMBING LINES INDICATE BELOW FLOOR ELEVATION UNLESS OTHERWISE NOTED ON DRAWINGS. DHW DHC DCW OVERFLOW PIPE ST ST (F) FUTURE DCW METER OR DCW / GASM SUB-METER M GAS METER AXIOM MODEL SF100 W/ INTERNAL FLEXIBLE CONNECTOR HOSE, CHECK MODEL PBLS10 FLOAT CUT OFF SWITCH UNISTRUT PIPE CLAMP MINIMUM OF 2 NO SCALE 4" CONCRETE PAD. FLOOR TO BOILER FILL LOCATION FLEX POWER CORDS MODEL RIA10 ALARM PANEL W/ ALARM LITES AND BUZZER, TEST, OFF & FLOAT SWITCHES. 115 V, 1 PHASE PUMP. VALVE AND STRAINER, AND 1/4 HP, GLYCOL FEEDER ASSEMBLY 1 1 M002 10/03/17