HomeMy WebLinkAboutB17-0282_P002_1507064553.pdf1-1/2" REDUCED PRESSURE BACKFLOW ASSEMBLY BASEMENT LEVEL FIRST LEVEL 1-1/2" COLD WATER FLATOMETRIC SECOND LEVEL THIRD LEVEL RVB1 1/2" WC BT WC LAV SH LAV LAV WB1 RVB1 1/2" SINK 1/2" RVB1 1/2" LAV LAV BT WC WC BT 1/2" LAV 1/2" LAV RVB1 1/2" SINK LAUN. SINK SINK 1/2" WB1 LAV WC RVB1 1/2" WC LAV LAV WB1 1/2" SG1 1/2" SH 1/2" LAV LAV WH1 3/4" SH BT WC M (N) 1-1/2" DCW METER 1-1/4" 1" 1" 1" 1" 1" 1" 1" 3/4" 3/4" 1/2" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4"1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" IWH1 1-1/2" 1-1/2" 1-1/4" SANITARY WASTE & VENT FLATOMETRICS GRADE LEVEL ROOF LEVEL 4" WCO 4" 4" 2"FS1 AAV 2" WCO 4" WC1 4" BT 2" 2" LAV AAV 2" WCO LAV AAV 2" 2" BT 2" 2" LAV 2" 2" LAV WC 4" 2" WCO 4" 4" 2" 2" 4" WCO 4" 4" ROOF LEVEL 4" WCO 4" 4" WB1 AAV 2" 3" WCO 4" LAV 2" 2" WC 4" 2" SH 2" 2" 4" 3"VTR 2" SINK AAV 2" WCO BT 2" LAV AAV 2" WCO LAV AAV 2" WC1 4" 4" 4" 4" 4" 4" WCO 4" 4" 4" 4" SINK AAV 2" WCO SINK AAV 2" WCO 4" WCO 4" 4" 4" WC1 4" LAV AAV 2" BT 2" WCO LAV AAV 2" SH 2" 2" 3" 3" 2"FS1 AAV 2" WCO WB1 AAV 2" 3" WCO LAV 2" 2" LAV 2" 2" WC 4" 2" WCO SH 2" 2" 3"VTR 3" 2" 2" 2" 2" 2" 2" 4" WC1 4" WCO LAV AAV 2" WB1 AAV 2" 3" WCO WCO LAUNDRY AAV 3" 4" 3" 2" WCO 2" 2" HOT TUB AAV 2" WCO BASEMENT LEVEL FIRST LEVEL 1-1/2" HOT WATER FLATOMETRIC TIE (E) FIXTURES TO REMAIN INTO (N)1-1/2" DCW LINE SECOND LEVEL THIRD LEVEL TIE (E) FIXTURES TO REMAIN INTO (N)1-1/2" DCW LINE BT LAV SH LAV LAV WB1 LAV LAV BT BT LAV 1/2" LAV LAUN. SINK SINK 1/2" WB1 LAV LAV LAV WB1 SH LAV LAV SH BT 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/2" 1-1/2" 1-1/2" IWH1 1-1/2" 1/2" DW 1/2" SINK DW 1/2" 1/2" DW 1/2" SINK 1/2" 1/2" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" SEE DETAIL FOR CONTINUATION 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" M GAS PIPING FLATOMETRIC 1-1/2" FIRST LEVEL 2" 1-1/2" SECOND LEVEL THIRD LEVEL GAS METER BY XCEL ENERGY, 2362 CFH TOTAL GAS LOAD, 14" W.C (1/2# PRESSURE), 150 FEET LONGEST RUN, 2" GAS MAIN LINE GPRV3 35 CFH 50 FEET 35 CFH GAS STOVE BASEMENT GPRV1 797 CFH 30 FEET 399 CFH (N) B-1 1-1/4" (N) 1-1/4" 199 CFH (E) BOILER (E) 1" 199 CFH (E) BOILER (E) 1" GPRV2 1187 CFH 80 FEET 100 CFH QK DSCNCT 229 CFH RANGE 200 CFH BBQ 229 CFH FIREPLACE 1-1/4" 100 CFH QK DSCNCT 100 CFH QK DSCNCT 3/4" 229CFH FIREPLACE 2" 2" 1-1/4" 2" 1-1/4" 1-1/4" 2" 1-1/2" 3/4" 3/4" 3/4" 1-1/4" 2" 181 CFH (E) BOILER (E) 3/4" 181 CFH (E) BOILER (E) 3/4" PROVIDE (N) GPRV IF (E) BOILERS REQUIRE LOWER PRESSURE TO OPERATE (E) 1" 1-1/4" 1-1/4" 1" 11' 16' 12' 6' 74' 7' 44' 1' 3' 8' 6' 19' 17' 22' 3/4" 8' 6' 15' 32' 8' 6' 47' 65' 8' 12' 34' 5' 3' 11' 8' 8' TO DRAIN. AIR GAP FITTING BY BACKFLOW NOTES: 1. DETAIL IS FOR WATER SERVICES OF 2" OR SMALLER. PREVENTOR MFGR. WITH STRAINER WILKINS MODEL 375XL TO A MAX. OF 48" A.F.F. THE DEVICE SHALL BE PLACED A MIN. OF 6" FROM THE WALL TO THE CENTER OF THE DEVICE WITH A MIN. OF 24" OF CLEAR SPACE IN FRONT SPACE IN FRONT OF THE DEVICE FROM FLOOR TO CEILING. 2. RPBD SHALL BE PLACED A MIN.OF 24" A.F.F. BALL VALVE, TYP. WATER SERVICE NO SCALE WATER SUPPLY TO SYSTEM. BACKFLOW PREVENTER REDUCED PRESSURE FULL SIZED REDUCED PRESSURE BACKFLOW ASSEMBLY DETAIL PRESSURE REDUCING VALVE FOR PRESSURES OVER 80 PSI W/ WILKINS AG-5 AIR GAP NO SCALE WASTE & VENT ISOMETRIC DISHWASHER & 1-COMP. SINK 2" 2" WASTE FULL SIZED WASTE DISCHARGE DISHWASHER W/ DISPOSER APPROVED AIR GAP DEVICE KITCHEN SINK 9" CEILING FLOOR 1/4" O.D. TUBE F.B.O. FLOOR 3-5/8" FINISHED WALL 1/2" PIPE OR COPPER TUBE COMPRESSION ANGLE VALVE 1/2" FPT IN x 1/4" COMP. OUT AS REQUIRED BY MANF. NO SCALE NOTE: 6-1/4" 1/2" FPT x 1/2" MPT OR 5/8" CSW BRASS CONNECTOR INSTALLATION HEIGHT MAY VARY WITH EACH MANF. 10-3/4" 9" ICE MAKER WATER SUPPLY NO SCALE DETAIL SINGLE SINK AIR ADMITTANCE VALVE AIR ADMITTANCE VALVE 1-1/2" TO MAIN MIN 4" MIN 2 DIA LAV/SINK STUDOR MINI-VENT OR EQUAL NO SCALE DETAIL SINGLE SINK AIR ADMITTANCE VALVE AIR ADMITTANCE VALVE DRAINBOARD 1-1/2" TO MAIN TO DISHWASHER AIR GAP FITTING WHEN USED DISPOSAL INSINKERATOR MODEL PRO 333 3/4HP, 120V MIN 4" MIN 2 DIA LAV/SINK STUDOR MINI-VENT OR EQUAL APPROVED DISHWASHER SHOCK ABSORBER NO SCALE WASHER STANDPIPE DETAIL W/ SHOCK ARRESTERS V 6" MIN. 18" MAX. 18" MIN. 30" MAX. WB1 WASHER BOX 4" MIN. 2" 1/2" HW 1/2" CW FLOOR AAV 3" NO SCALE FLOOR SINK FLASHING DETAIL WATERPROOFINGGRATE TO BE FLUSH TO -1/16" TO FINISHED FLOOR CLAMP COLLAR SEEPAGE PAN ANTI-SPLASH DOME STRAINER CONCRETE TRAP PRIMER CONNECTION FURNISHED WHEN SPECIFIED MEMBRANE 36"x36" NO SCALE GAS SUPPLY GAS APPLIANCE FULL SIZE DIRT LEG REDUCER AS REQUIRED. UNION AGA APPROVED SHUT-OFF VALVE APPLIANCE GAS CONNECTION ASSEMBLY P002 PLUMBING DETAILS & FLATOMETRICS OWNER PROJECT NO.: 21074.00 VAIL, COLORADO 81657 311 BRIDGE STREET LANDSCAPE SHERRY DORWARD P.O. BOX 3766 VAIL, CO 81658 ARCHITECT ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT. STUITE 117 DENVER, CO 80216 HILL BUILDING RENOVATION 39°38'24"N 106°22'25"W STRUCTURAL MONROE NEWELL 70 BENCHMARK RD. SUITE 204 AVON, CO 81620 ENGINEER MEP DMCE ENGINEERING 5737 6TH AVE. LAKEWOOD, CO 80214 ENGINEER CIVIL ALPINE ENGINEERING, INC. 34510 HIGHWAY 6 UNIT A-9 EDWARDS, CO 81632 ENGINEER TOWN OF VAIL USE ISS.# DESCRIPTION DATE S BUILDING PERMIT ISSUE 2017-07-07 01 BUILDING DEPT COMM. 2017-08-16 1 02 PERMIT REVISIONS 2017-08-25 2 1 1 10/03/17