Loading...
HomeMy WebLinkAboutB17-0282_P100_1507064554.pdf399 CFH 199 CFH 199 CFH (E)BOILER (E)BOILER (N)B-1 HW, CW & RECIRC. LINES UP TO LEVEL ABOVE GENERAL NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING PLUMBING CONDITIONS PRIOR TO ORDERING AND INSTALLATION OF NEW PLUMBING EQUIPMENT/SYSTEMS. NOTIFY ENGINEER IN WRITING WITH ANY DRAWING/DESIGN DISCREPANCIES. 2. FIELD VERIFY LOCATIONS OF ALL SANITARY WASTE, GAS AND WATER RISERS IN/ON WALLS PRIOR TO INSTALLATION. DEMO (E) 3/4" DCW METER & WATER ENTRY & REPLACE W/ (N) 1-1/2" DCW METER, TAP & SERVICE LINE, FIELD VERIFY EXACT LOCATION OF WATER LINE ENTERING BUILDING W/ OWNER/ARCHITECT/CIVIL PRIOR TO DEMO & INSTALLATION (E) FLOOR DRAIN TO BE CLEANED OUT AND TO BE IN OPERATING CONDITION (N) IWH1 REMOVE ALL EXISTING PIPING, ZONE VALVES. PUMPS, ETC. FROM EXISTING BOILERS. RE-ROUTE EXISTING ZONE VALVES FROM THIS MECHANICAL ROOM THAT SERVE THE RETAIL SPACE TO OTHER MECHANICAL ROOM BOILER MANIFOLD. PROVIDE ALL NEW PIPING, PUMPS, ETC. PER BOILER PIPING SCHEMATIC, SHEET M002 RCP1 ROUTE AS HIGH AS POSSIBLE AND FIELD VERIFY BEST ROUTING W/ OWNER/ARCHTIECT PRIOR TO INSTALLATION (N) 1-1/4" GAS LINE M RELOCATE (E) WATER SOFTENER AS NECESSARY (N) 1-1/4" TIE (E) 1" GAS INTO (N) 1-1/4" (E) 1" (N) 1-1/2" GAS LINE GPRV1, 797 CFH, 30 FEET (N) 1-1/2" DCW METER (N) 1-1/2" DCW REDUCED PRESSURE BACKFLOW PREVENTER, WILKINS MODEL 375XL W/ AG-6 AIR GAP, 1-1/2" RPBFP TO BE LOCATED UNDER 1-1/2" DCW METER, SHOWN TO THE SIDE FOR CLARITY FIELD VERIFY WITH OWNER/ARCHITECT/ STRUCTURAL (N) GAS & DCW PIPE ROUTING OUT OF ROOM PRIOR TO INSTALLATION TIE ALL (E) WATER LINES IN ROOM BACK INTO (N) 1-1/2" DISNTRIBUTION LINE GAS LINE FROM ABOVE DCW DCW DHW DCW DHC GG G G WILKINS MODEL 705 DOUBLE CHECK BACKFLOW PREVENTER 3/4" DCW TO BOILER SYSTEM 181 CFH 181 CFH (E)BOILER (E)BOILER (E) GAS LINE TIE (E) GAS LINE INTO NEW GAS LINE (E) HTP INDIRECT WATER HEATER PRV 1 1 1 PROVIDE 3"FS1 IF EXISTING DRAIN DOES NOT EXIST, TIE NEW 3" INTO CLOSEST SANITARY WASTE, 3" MIN., FIELD VERIFY LOCATION PRIOR TO INSTALLATION 1 MM KK JJ II GG EEA EE CC AA A B 3 5 Z YA Y XN X 15 ZA 6A K.5 13.5 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2 C D E F G H I J K L M 2 E.5 L.5 OWNER PROJECT NO.: 21074.00 VAIL, COLORADO 81657 311 BRIDGE STREET LANDSCAPE SHERRY DORWARD P.O. BOX 3766 VAIL, CO 81658 ARCHITECT ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT. STUITE 117 DENVER, CO 80216 HILL BUILDING RENOVATION 39°38'24"N 106°22'25"W STRUCTURAL MONROE NEWELL 70 BENCHMARK RD. SUITE 204 AVON, CO 81620 ENGINEER MEP DMCE ENGINEERING 5737 6TH AVE. LAKEWOOD, CO 80214 ENGINEER CIVIL ALPINE ENGINEERING, INC. 34510 HIGHWAY 6 UNIT A-9 EDWARDS, CO 81632 ENGINEER TOWN OF VAIL USE ISS.# DESCRIPTION DATE S BUILDING PERMIT ISSUE 2017-07-07 01 BUILDING DEPT COMM. 2017-08-16 1 02 PERMIT REVISIONS 2017-08-25 2 P100 BASEMENT PLUMBING PLAN 1 SCALE: 1/4" = 1'-0" BASEMENT PLUMBING PLAN 10/03/17