Loading...
HomeMy WebLinkAboutDRB17-0241_A254_1501187700.pdfKK II GG EE CC AA B E.5 K.5 MM A C D E F G H I J K L M L2 TOP OF PLYWOOD EL. 109'- 4 5/8" L1 TOP OF PLYWOOD EL. 100'- 0" L0 TOP OF CONC. EL. 90'- 7 3/4" TOP OF EXISTING PEAK TOP OF EXISTING CHIMNEY EL. 139'- 9" EL. 137'- 3 1/4" L1 FINISH FLOOR EL. 100'- 2" TOP OF EXISTING PEAK EL. 132'- 4 3/8" L2.5 FINISH FLOOR EL. 119'- 11" L3 FINISH FLOOR EL. 124'- 2" EEA L.5 JJ L2 FINISH FLOOR EL. 109'- 9" EXISTING PEAK 4 3/8" 3'-0" TYPICAL ROOF ASSEMBLY TYPICAL BASEMENT FLOOR ASSEMBLY EXISTING FLOOR FINISH OVER EXISTING CONCRETE SLAB BUILDING SECTION NOTES FINAL EXTERIOR INSULATION R-VALUE AND THICKNESS TBD ACOUSTIC ISOLATION FOR RESIDENCE TBD INTERIOR FINISHES TBD WALL ASSEMBLIES SUBJECT TO CHANGE SEE ELEVATIONS FOR EXTERIOR WALL FINISH TYPICAL LEVEL 1 FLOOR ASSEMBLY EXISTING FLOOR FINISH OVER EXISTING PLYWOOD SUBFLOOR EXISTING 2X WOOD JOIST EXISTING GWB CEILING EXISTING SPRINKLER SYSTEM TYPICAL LEVEL 2 FLOOR ASSEMBLY TYPICAL LEVEL 3 FLOOR ASSEMBLY STAIR 210 DINING ROOM 202 FAMILY ROOM 218 SOUTH BALCONY 231 STAIR 110 TENANT SPACE 051 WC 303 TENANT SPACE 151 ENTRY 101 RECEPTION 209 KITCHEN 219 HALL 309 MASTER BATHROOM 302 SOUTH BALCONY 331 YOGA STUDIO BALCONY 332 CARETAKER'S WEST BALCONY 333 COPPER ROOF SHINGLE PANELS (STYLE & LAYOUT TBD) W/ COPPER CLEATS OVER 30 LB. ROOFING FELT OVER (HIGH-HEAT) OVER ICE & WATER SHIELD UNDERLAYMENT OVER ATLAS-ACFOAM 4-1/2" NAILBASE, INSULATION (ASSUME TOTAL R-VALUE=24.2) OVER 4-1/2" POLYISO INSULATION (ASSUME Total R-VALUE =26.8) OVER SELF-ADHERING MEMBRANE AIR/VAPOR BARRIER OVER 1/2" PLYWOOD PER STRUCTURAL OVER, (ASSUME TOTAL R-VALUE=0.62) OVER T&G DOUG-FIR ROOF DECKING, (ASSUME TOTAL R-VALUE=3), RE: SPEC. OVER ASSUME COPPER BYLIN ROOF ICE MELT SYSTEM AT PERIMETER EXPOSED ROOF BEAMS, RAFTERS & PURLINS PER STRL. SNOW GUARD PER ROOF PLAN 3/4" WOOD FLOORING (ASSUME TILE IN BATHROOMS, POSSIBLY CARPET IN BEDROOM) 1-1/8" WARMBOARD-S 11-7/8" BCI'S PER STRUCTURAL 3-1/2" DROPPED FURRING 1/2" SOUND BOARD 1/2" RESILIENT CHANNEL 3/4" WOOD PANELING NEW SPRINKLER SYSTEM RE: RCP's FOR DROPPED CEILING LOCATIONS 3/4" WOOD FLOORING (ASSUME TILE IN BATHROOMS) 1-1/8" WARMBOARD-S 2X3 SLEEPERS WITH ACOUSTIC INSULATION ON 1/8" ACOUSTIC MAT 30-LB FELT ISOLATION BARRIER EXISTING 3/4" PLYWOOD SUBFLOOR OR NEW 3/4" PT PLYWOOD SUBFLOOR EXISTING 2X WOOD JOISTS OR TJI's EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION TBD) EXISTING SPRINKLER SYSTEM STONE WALL ASSEMBLY AT CHIMNEYS 4" STONE VENEER W/WEEPS AS REQ'D 1/8" DRAINAGE MAT 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN EXISTING CLAY FLUE RE: STRL. & SPEC., TYP. FINAL INTERIOR FINISH TBD EXTEND EXISTING CHIMNEY TO MIN. HEIGHT REQUIRED TO MEET CODE REQUIREMENTS, RE: STRUCTURAL FOR SUPPORT A254 SECTION BUILDING OWNER PROJECT NO.: 21074.00 ISS.# DESCRIPTION DATE NOT FOR CONSTRUCTION VAIL, COLORADO 81657 311 BRIDGE STREET LANDSCAPE SHERRY DORWARD P.O. BOX 3766 VAIL, CO 81658 ARCHITECT ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT. STUITE 117 DENVER, CO 80216 HILL BUILDING RENOVATION 39°38'24"N 106°22'25"W STRUCTURAL MONROE NEWELL 70 BENCHMARK RD. SUITE 204 AVON, CO 81620 ENGINEER MEP DMCE ENGINEERING 5737 6TH AVE. LAKEWOOD, CO 80214 ENGINEER CIVIL ALPINE ENGINEERING, INC. 34510 HIGHWAY 6 UNIT A-9 EDWARDS, CO 81632 ENGINEER TOWN OF VAIL USE 1/4" = 1'-0" BUILDING SECTION L DD PROGRESS 2017-04-14 N DESIGN DEVELOPMENT SET2017-05-26 Q DRB SUBMITTAL 2017-06-12 DRB APPROVED 7/19/2017 12:00:00 AM