Loading...
HomeMy WebLinkAboutB17-0305_A2.1_1506116606.pdfUP UP A3.1 A3.2 1 A3.2 1 2 3 A4.4 6 A4.2 5' - 0" 14' - 5 1/2" 14' - 6 1/2" 11' - 6" 8' - 6" 14' - 0 1/2" 8' - 0" 1 A4.1 1 A4.1 4 A4.2 (LOCKOFF) TRASH RECYCLE AREA UNDER HALF LEVEL FOR STORAGE 5'-0" MAX CEILING NO GRFA. HEATED SPACE WITH CONDITIONED AIR SUPPLY R403.3 EXCEPTION 2.2. UNDER- STAIR STORAGE UP TO GARAGE LEVEL UP TO MAIN LEVEL 3 A4.2 5 A4.3 1 A4.3 13' - 4" 24' - 0" 10' - 8 1/2" 9' - 0" 19' - 0" 48' - 7" EAST HOUSE WEST HOUSE A B CONC. DRIVEWAY CONC. DRIVEWAY STORAGE CONCRETE STOOP CONCRETE STOOP CONCRETE STOOP DECK ABOVE STONE VENEER PIER DECK ABOVE STONE VENEER PIER STONE VENEER WALL STEEL POST & BEAM STEEL POST & BEAM 76' - 0 1/2" 38' - 8 1/2" 37' - 4" 76' - 0 1/2" G GAS METER GAS METER LOCATION (UNDER W.P. DECK) UNIT A ELECTRICAL METER CLOSET UNIT B - ELECTRICAL METER CLOSET 0' 2' 4' 8' 16' -11' - 7 3/4" FUTURE HOT TUB PATIO 8' - 0" 18' - 0" 22' - 7" 25' - 1 1/2" 18' - 5 1/2" 13' - 0" 2' - 8" 3 CAR GARAGE B100 ENTRY B101 MUD ROOM B102 GUEST BEDROOM B103 GUEST CL. B104 GUEST BATH B105 MECH / STORAGE B106 STAIR B107 2 CAR GARAGE A100 20' - 11 1/4" 4' - 1 1/4" 9' - 4" 14' - 2 1/2" 2' - 7" 18' - 0" 4' - 1" 5' - 4 1/4" 4' - 11 3/4" 1' - 10" 5' - 10" BEDROOM 2 A104 BATH 2 A105 BEDROOM 1 A107 BATH 1 A109 W.I.C. 1 A108 MECH / STORAGE A110 MUD ROOM A102 OWNER ENTRY A101 W.I.C. 2 A106 7' - 6 1/2" 8' - 0" 4' - 10" 1' - 5" 9 1/2" B101 B102 B103b B105 B106 B104 A100 A101 B103 106 105 A107 A104a A106 A105 A108 A109 A110 A102 107 A104b 103 104 101 102 100 4' - 0 1/2" 4' - 11 1/2" 1' - 5 7/8" 4' - 5" 6' - 11 1/2" 6' - 5 1/2" 5' - 0" 4' - 4" 7' - 9" 6' - 4 5/8" 10' - 1" 4' - 4 1/2" 3' - 10 1/8" 4' - 3 1/2" 5 3/8" 12' - 6" 5' - 6 3/4" 3' - 8" 11 1/4" 8' - 9 1/2" 9' - 8" 2' - 10" 10' - 3 3/4" 2' - 9 1/2" 7' - 8" 5' - 5 1/2" 5' - 4 7/8" 1' - 5 1/8" 9' - 0" 7' - 4 1/2" 7' - 8" 3' - 3 3/4" 5' - 4 3/4" 8" 3' - 1 3/4" 3' - 8 1/4" 2' - 0 1/2" HIGH-EFFICIENCY (MIN. 92%) DIRECT VENT, SEALED BOILER FOR IN-FLOOR RADIANT HEATING SYSTEM INTAKE AND EXHAUST: 2 PVC PIPES. INDIRECT WATER HEATER "SIDE-ARM" WATER STORAGE TANK WRAP W/ TANK INSULATION. R @7 3/8" 9 R @7 1/2" 9 FURRING AT FOUNDATION WALL MECH AND RADON PVC PIPES - TO CHASE ABOVE MECH AND RADON PVC PIPES - TO CHASE ABOVE CUBBIES 12' - 0" 3 A5.0 1 A4.2 5' - 6 3/4" 13' - 5 1/4" 8 1/4" 3' - 11 1/2" STAIRS OVERHANG WALL BELOW 11 3/4" 6' - 3 7/8" 1 A4.4 2 A4.2 10' - 0" 2' - 6 1/2" 9' - 9" 3' - 0" 2 A4.1 10' - 8 1/2" 4 A5.0 5 A5.0 HIGH-EFFICIENCY (MIN. 92%) DIRECT VENT, SEALED BOILER FOR IN-FLOOR RADIANT HEATING SYSTEM INTAKE AND EXHAUST: 2 PVC PIPES. INDIRECT WATER HEATER "SIDE-ARM" WATER STORAGE TANK WRAP W/ TANK INSULATION. FD FD FD FD SLOPE 3' - 11" 7' - 10 1/2" 2' - 3" 1 2 3 4 5 6 7 8 9 10 11 12 A A B B C D E F J L G N N M M K K H G 1' - 2" FAMILY ROOM A 102 MECHANICAL NOTE: THIS ROOM MUST MEET THE EXCEPTION TO "PROVIDE LIGHT AND VENTILATION R303.1" USING WHOLE HOUSE VENTILATION DESIGNED IN ACCORDANCE WITH M1507 AND ARTIFICIAL LIGHT MEETING EXCEPTION 2. THE MECHANICAL SYSTEM TO BE DESIGN- BUILD BY THE MECHANICAL CONTRACTOR. SEE ECO SHEET NOTE 4. ACCESS DOOR LOT SPLIT LINE EXTERIOR WALLS LESS THAN 3 FT. FROM PROPERTY LINE SHALL BE ONE-HOUR RATED (1 LAYER EXTERIOR GRADE 5/8" TYPE X DRYWALL) AND WITH NO OPENINGS. TABLE R302.1(2). LOT SPLIT LINE 3' - 7" 1 1 1 A306 AM1 BM1 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 8/29/2017 4:18:05 PM A2.1 LOWER LEVEL PLAN 1719 1709 GENEVA DUPLEX PERMIT SET 8-4-17 DAVE HILB 1709 GENEVA DRIVE, VAIL, CO MATTERHORN VILLAGE FILING 1, LOT 4 1/4" = 1'-0" 1 1. LOWER LEVEL NORTH PERMIT SET DATE: 8-4-17 No. Description Date 1 Permit Revisions 1 8-29-17 09/22/17