HomeMy WebLinkAboutB17-0307_A1.0_1511211646.pdf10' EASEMENT (PER RECORD PLAT)
8016.4
8021.3
8026.4
8031.3
PHONE PEDESTAL
SEWER MANHOLE
RIM ELEV. = 8017.8'
CONCRETE
PAN
WOOD FENCE
FOUND BLUE PLASTIC CAP
ON A REBAR, LS No. ILLEGIBLE
(ELEV. = 8006.9')
NORTHEASTERLY CORNER OF LOT 7
FOUND ALUMINUM CAP
ON A REBAR, LS No. 23089
LOT 5
LOT 4
LOT 3GENEVA DRIVE (50' R.O.W.)VAIL VILLAGE WESTFILING No. 1S88° 55'24"E - 168.55'N01° 04'36"E - 104.10'S88° 55'24"E - 168.55'N01° 04'36"E - 104.10'80068008801280148016
801 8
8 022
8024
8026
8028 802880268024802280188016801480128008
8006
8004
800480108020
8030 80208010SPHMAGNETIC10' EASEMENT (PER RECORD PLAT)
8016.4
8021.3
8026.4
8031.3 LOT 5
LOT 4
LOT 3GENEVA DRIVE (50' R.O.W.)VAIL VILLAGE WESTFILING No. 1S88° 55'24"E - 168.55'N01° 04'36"E - 104.10'S88° 55'24"E - 168.55'N01° 04'36"E - 104.10'800680088012801480 16
8 0 1 8
80 2 2
8 0 2 4
8 0 26
8 0 28 802880268024802280188016801480128 0 0 8 8 00 6
8 0 0 4
800480108 0 20
803 0 80208010MAGNETIC28.3'28.5'28.3'28.5'
10' EASEMENT (PER RECORD PLAT)
8016.4
8021.3
8026.4
8031.3
PHONE PEDESTAL
MANHOLE
V. = 8017.8'
CONCRETE
PAN
WOOD FENCE
FOUND BLUE PLASTIC CAP
ON A REBAR, LS No. ILLEGIBLE
(ELEV. = 8006.9')
WOOD DECK
WOOD DECK
WOOD
STEPS
EDGE OF
CONCRETE
WALKWAY
INDICATES AN
EVERGREEN TREEINDICATES A
DECIDUOUS TREE
SINGLE FAMILYRESIDENCE
0.4028 ACRES
1709 GENEVA DRIVE36"W - 208.20'LOT 5
LOT 4 VAIL VILLAGE WESTFILING No. 1S88° 55'24"E - 168.55'N01° 04'36"E - 104.10'S88° 55'24"E - 168.55'N01° 04'36"E - 104.10'800680088012801480 1 6
80 1 8
80 2 2
8 0 2 4
8 0 2 6
8 0 2 8 802880268024802280188016801480128 0 0 8
8 0 0 6
8 0 0 4
800480108 0 20
803 0 80208010SPH18
19
17 16
15
13
14 13
12 10
ENTR
Y
SNOW STORAGE
AREA = 535 SQ. FT.
24
(5%)(8%) (8%)
(5%)
LOWER LEVEL (BASEMENT) 8016'-4 1/4" (-10'-7 3/4")
MAIN LEVEL 8027'-0" (0'-0")
UPPER LEVEL 8037'-1 3/4" (10'-1 3/4")
LOWER LEVEL (BASEMENT) 8009'-10 1/4" (-17'-1 3/4")
MAIN LEVEL 8021'-0" (-6'-0")
UPPER LEVEL 8031'-1 3/4" (4'-1 3/4")
(8%)
UNIT B - SECONDARY UNIT (EAST SIDE) UNIT A - PRIMARY UNIT (WEST SIDE)
(2.5%)(5%)
(5%)
(5%)GARAGE 8015'-10 1/4"
GARAGE 8015'- 4 1/4"
8016' - 2 1/4"
8008' - 10 1/4"
8026' - 0"
ENT R Y
1 3/4" / 1 2 " 1 3/4" / 12 "
S N OW S TORA
G
E
AREA = 36 5 S Q. F T.
CONCRETE DRIVEWAY
3,000 SQ. FT.
(UNHEATED)
REQUIRES 900 SQ. FT.
OF SNOW STORAGE
RIDGE 801880208022801680148012801080089 X1 8
CAR
9 X18
CAR
9 X1 8
CAR
9 X19
CAR
9 X1 8
C AR 9X18
CAR 9 X1 9
CAR
9 X19
CAR
CONCRETE
PATIO 450 S.F.
CONCRETE
PATIO 300 S.F.
CONC. WALK
ON-GRADE STEPS
W/ HANDRAIL
CONC. WALK
1' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8011'-0"
T.O.W. = 8012'-0"
3' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8014'-0"
T.O.W. = 8017'-0"
2' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8010'-0"
T.O.W. = 8012'-0"2' - 0"NO WALLS
WITHIN
24" OF
PROPERTY
LINE
EXISTING CONC. PAN
MEETS T.O.VAIL
ENGINEERING
STANDARDS
HEATED DRIVEWAY NOTE:
PROVIDE SEPERATE HEAT
ZONE TO PAVEMENT AREAS
WITHIN T.O.VAIL PROPERTY
MARKED TOV OR ROW AT
CONTROL BOX.
SPECIAL INSPECTIONS NOTE:
THE GENERAL CONTRACTOR MUST SCHEDULE SPECIAL
INSPECTIONS WITH THE GEOTECHNICAL ENGINEER AS
DESCRIBED IN THE SOILS INVESTIGATION REPORT
T.O.VAIL SITE PLAN NOTES:
1. NO RETAINING WALLS WITHIN 24" OF PROPERTY LINES.
2. 8% MAX SLOPE FROM EDGE OF ROADWAY FOR FIRST 10 FT.
3. ALL RETAINING WALLS OVER 4'-0" HEIGHT SHALL BE
DESIGNED AND STAMPED BY A PROFESSIONAL ENGINEER.
5. UTILITY SCARS TO BE RE-GRADED TO NATURAL GRADE AND
RE-SEEDED W/ NATURAL VEGETATION.
6. NO FINISH GRADES BETWEEN RETAINING WALLS TO
EXCEED 2:1 SLOPE.
LIMITS OF DISTURBANCE FENCE:
USE EROSION CONTROL SILT FENCE
ON DOWNHILL PORTION OF LOT
8041' - 9 1/2"
RIDGE RIDGE
RIDGE CRITICAL HEIGHT 32'-11"
8039' - 0 1/2"
RIDGE
8033' - 9"
8035' - 0 3/4"
8037' - 10 1/2"
A BO V E GR ADE DEC K
AB O V E GRA DE DE CK
L OT S P L IT L INE
LOT SPLIT LINE
20' - 0"15' - 0"10' - 0"15' - 0"
10' - 0"15' - 0"10' - 0"EASEMENTSETBACKSETBACK
EASEMENTSETBACKEASEMENT
FRONT YARD
SETBACK
EXISTING TREES TO REMAIN
2' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8018'-0"
T.O.W. = 8020'-0"
FOUNDATION DRAIN
TERMINATION AT LOWER
GRADES TO DAYLIGHT OR
UNDERGROUND GRAVEL
PERCOLATION DRAIN
8044' - 7 1/4"
8045' - 9 1/4"
8049' - 8 3/4"
8050' - 4"
OVERHEAD ELECTRICAL LINE TO REMAIN
OVERHEAD ELECTRICAL LINE TO BE
REROUTED TO NEW DUPLEX AND BURIED.
ELECTRICAL POLE TO REMAIN
OVERHEAD ELECTRICAL LINE TO BE RE-
ROUTED ABOVE GROUND TO NEXT POLE TO
THE NORTH. WILL STAY WITHIN REAR UTILITY
EASEMENT.
OVERHEAD ELECTRICAL LINE TO REMAIN
G
G
G
G
G G
G
G
G
G G G
G
G
G G
G
E
E
E
E
E
E E E E
E
E
E
E
E
E
E
E
PH
PH
PH
PH
PH
P H
P H
P H
PHPH PH PH
PH
P H
P H
PH
W
W
ME C H .RO OM
ME C H.
ROOM
W
W
W W W W W W W W W W W W
W
W
W
W
S SS S S S S S
S
S
S
S
S
S S S
S
S
S
S
CONTRACTOR TO
VERIFY LOCATION OF
WATER CONNECTION
CONTRACTOR TO
VERIFY LOCATION OF
GAS CONNECTION
GAS METER
UNDER W.P.
DECK
UNI T B MET ER C L OSET
GAS
M ET E R
ELECTRICAL LINE BURIED
PNONE AND CABLE LINE BURIED
0' 4' 8' 16' 32'
NORTH
E
U NI T A
M E T E R
C L OSET
1
G
G
E
EPH
EPH
E
PH
1
1
1
8045' - 10 7/8"
RIDGE CRITICAL HEIGHT 32'-9"
8018' - 0"
14
2' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8016'-0"
T.O.W. = 8018'-0"
2' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8012'-0"
T.O.W. = 8014'-0"
1' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8015'-0"
T.O.W. = 8016'-0"
2' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8012'-0"
T.O.W. = 8014'-0"
3' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8007'-0"
T.O.W. = 8010'-0"
3' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8009'-0"
T.O.W. = 8012'-0"
2' HEIGHT BOULDER
RETAINING WALL
B.O.W. = 8012'-0"
T.O.W. = 8024'-0"2:1 SLOPESMAX.8014' - 5"
15
NOTE: THE ENTIRE BUILDING HAS MOVED UP 30"
AND THE ENTIRE LOT HAS BEEN RE-GRADED. THIS
IS TO ALLOW POSITIVE FLOW FOR THE SANITARY
SEWER LINES TO THE STREET.
4
4
ENTRY
24 22
SINGLE-FAMILY
HOUSE
TO BE COMPLETELY
DEMOLISHED
LIMITS OF DISTURBANCE FENCE:
USE EROSION CONTROL SILT FENCE
ON DOWNHILL PORTION OF LOT
OUTLINE OF PROPOSED
DUPLEX RESIDENCE
OVERHEAD ELECTRICAL
LINE TO REMAIN
OVERHEAD ELECTRICAL
LINE TO BE BURIED
ELECTRICAL POLE
TO REMAIN
OVERHEAD ELECTRICAL
LINE TO BE RE-ROUTED
OVERHEAD ELECTRICAL
LINE TO REMAIN
15 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS10/9/2017 4:26:41 PMA1.0SITE PLANS17191709 GENEVA DUPLEXPERMIT SET9-25-17DAVE HILB1709 GENEVA DRIVE, VAIL, COMATTERHORN VILLAGE FILING 1, LOT 41" = 10'-0"1 SITE PLAN
1" = 20'-0"3 Site Plan TRUE NORTH'
LIGHTING LEGEND
COUNT: (6)
WALL SCONCE LIGHT FIXTURES.
HINKLEY "SHELTER" 1326 OUTDOOR
WALL LIGHT
SIZE: 4.5" W x 15.5" H x 4.8" D
EXTERIOR LIGHTS ALLOWED
1 PER 1,000 S.F. OF LOT AREA = 17 FIXTURES
EXTERIOR LIGHTS PROPOSED = 15 FIXTURES
LOT AREA (.538 ACRES) = 17,546 S.F.
RECESSED CAN CEILING LIGHT
FOR EXTERIOR USE
SELECTION BY OWNER/CONTRACTOR
SIZE: TO BE DETERMINED
COUNT: (9)
RECESSED CAN LIGHT FIXTURES.
SYMBOL A SYMBOL C
SYMBOL B
LED RECESSED WALL LIGHT
OUTDOOR WATERPROOF 1P54
MODERN WALL LAMP -
FOR EXTERIOR USE
SIZE: 125mm W x 225 mm H x 85mm D
COUNT: (5) NEAR GROUND, DOES
NOT COUNT TOWARDS MAX.
RECESSED CAN LIGHT FIXTURES.
A
A
A
A
A
A
B B
B
B
B
BB B
C
C
C
C
C
B
1" = 20'-0"2 SITE PLAN DEMO
PERMIT SET DATE: 8-4-17 No. Description Date1 Permit Revisions 1 8-29-174 Revision 4 10-9-17DRB
APPROVED
11/6/2017
12:00:00 AM
11/20/17