Loading...
HomeMy WebLinkAboutPEC17-0031_D1.02_1506638820.pdfUP UP 1 2 3 5 7 8 9 4 A B C D 6 10 / 1 D1.03 / 1 D1.03 / 1 D1.03 D204 D204D204D204D204D202D202 D209 D202 D202D206 D209D201D206 D209D211 D211 D211D211 D210D211D210 D210D211 D208 D208 D208 D208 D208 D208D208D208 D208D208 D208 D208D208D208 D208 D208 D208D208 D208D208 D208 D208 D208D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D206 D208 D213D213 D213 D209 D209 D209 D209D209D209 D209D210 D209 D202 D209D202 D209D202 D202 D209 D208 D203 D212 D212D212D212 D212 D212 D210 D209D211 D211 D202 D202 D205 14' - 6 1/2" D205 D205 D205D205D205 D205D205 D205 D201D201 D213 D213D209 D213 D213 D209 D209 D203 D203 D212 D212 D203 D227 D205 D205 D228 (E) COMPUTER CLASSROOM (E) PRE-K (E) PRE-K (E) MECH (E) CLASSROOM (E) CLASSROOM (E) CLASSROOM (E) KINDERGARTEN (E) JANITOR (E) CLASSROOM (E) CLASSROOM (E) CONFERENCE ROOM (E) OFFICE GENERAL DEMOLITION NOTES: 1. DEMOLITION GENERAL NOTES APPLY TO ALL DEMOLITION SHEETS. 2. COORDIANTE DEMOLITION AND PHASING EFFORTS WITH ARCHITECT AND OWNER'S REPRESENTATIVES. EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OWNER'S OPERATIONS AND TO PROVIDE BUILDING USER'S SAFETY. EXCESSIVE NOISE AND VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH OWNER'S REPRESENTATION. 3. COORDINATE DISRUPTION OF UTILITY SERVICES WITH OWNER AND AS SATISFIED. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS AND NOTIFY ARCHITECT OF DISCREPANCIES. 5. ITEMS NOT SHOWN DASHED ARE TO REMAIN. ALL DASHED ITEMS REPRESENT ITEMS TO BE REMOVED. COORDINATE REMOVAL WITH NEW ITEMS SHOWN IN DRAWINGS. 6. REMOVE EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, MARKERBOARDS, ETC. IN THEIR ENTIRETY AND AS REQUIRED TO EXECUTE DEMOLITION AND CONSTRUCTION WORK AS DESCRIBED ON THE DRAWINGS. 7. THE OWNER SHALL RESERVE THE RIGHT TO SALVAGE ANY MATERIALS. 8. PROVIDE PROTECTIONS FOR EXISTING BUIDLING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO DEMOLITION OR CONSTRUCTION- RELATED INCIDENT PREFORMED UNDER THIS CONTRACT. 10. REFER TO MEP AND STRUCTURAL DRAWINGS FOR ADDITIONAL ITEMS TO BE REMOVED, CAPPED OR ALTERED. 11. IF NEW CONSTRUCTION IS SHOWN ON OTHER DRAWINGS IT IS ASSUMED DEMOLITION IS REQUIRED IF EXISTING WALLS, FINISHES AND ETC. ARE CURRENTLY PRESENT. 12. CONTRACTOR TO COORDINATE REMOVAL OF EXISTING ITEMS WITH INSTALLATIONS OF NEW ITEMS. 13. COORDINATE NEW STRUCTURAL ITEMS WITH REMOVAL OF EXISTING ITEMS. REFER TO STRUCTURAL PLANS FOR ADDITIONAL STRUCTURAL WORK TO EXISTING STRUCTURE. 14. IT IS ASSUMED ITEMS NOT TAGGED AS REMOVED OR SALVAGED WILL BE REMOVED IF ATTACHED TO WALL, CABINET, OR OTHER ITEMS. THIS INCLUDES ITEMS ON WALLS, CEILINGS AND FLOORS. 15. ALL PLUMBING SHOWN AS DASHED AND NOT SPECIFICALLY NOTED WILL BE REMOVED. ALL PLUMBING NEEDS TO BE MODIFIED TO MATCH NEW LAYOUT. REFER TO PLUMBING PLANS FOR EXTENT OF WORK. 16. DRAWINGS ATTEMPT TO SHOW EXISTING CONDITIONS. BUT, ALL EXISTING CONDITIONS MAY NOT BE SHOWN OR VISIBLE ON SITE. CARE MUST BE TAKEN TO ABANDON, TURNOFF OR OTHERWISE SECURE EXISTING ELEMENTS THAT NEED TO BE REMOVED WITH REMOVED STRUCTURE. WHEN CONFLICTS ARE FOUND CONTACT ARCHITECT FOR DIRECTION. 17. REFER TO DEMO REFLECTED CEILING PLANS FOR ADDITIONAL WORK 18. ALL HARDWARE TO BE SALVAGED FOR OWNER OR REUSE FOR IN CONSTRUCTIONS. 19. SALVAGE AND STORE ALL EXISTING FURNISHINGS AND EQUIPMENT IN EXISTING SPACES NOTED FOR RENOVATION. DEMOLITION DEFINITIONS: 1. REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFF SITE, UNLESS OTHERWISE INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED. 2. SALVAGE: DETACH ITEMS FROM EXISTING CONDITIONS AND RETURN TO OWNER READY FOR REUSE. 3. REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONDITIONS, PREPARE THEM FOR REUSE, TEMPORARY STORE AS REQUIRED AND REINSTALL THEM AS INDICATED. 4. EXISTING: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, SALVAGED, OR REMOVED AND REINSTALLED. 5. DRAWINGS ATTEMPT TO SHOW EXISTING CONDITIONS. BUT, ALL EXISTING CONDITIONS MAY NOT BE SHOWN OR VISIBLE ON SITE. CARE MUST BE TAKEN TO ABANDON, TURNOFF OR OTHERWISE SECURE EXISTING ELEMENTS THAT NEED TO BE REMOVED WITH REMOVED STRUCTURE. EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN DEMOLITION LEGEND SHADED AREA NOT IN CONTRACT Architecture Engineering Planning Interiors © , DLR Group inc., a Colorado corporation, ALL RIGHTS RESERVED KEY PLAN LEGEND NOTES LEGEND NOTES ARE COMMON TO ALL SOME NOTES MAY NOT APPLY TO THIS SHEET Revisions A B STAMP NORTH 56 Edwards Village Blvd Suite 210 Edwards, CO 816362 970-766-1740 20178/25/2017 4:53:11 AM C:\Users\rachel\Documents\1627.02 RSES Bldg_CENTRAL_rachelXFKHW.rvt 1627.02 Red Sandstone Elementary School Renovation and Parking Garage - Vail Potato Patch Block 2 Lot 8 SCHEMATIC DESIGN SET Main Level Area A Demolition Floor Plan D1.02 08/28/17 551 N Frontage Rd West Vail, CO 81657 1/8" = 1'-0" D1.02 1 Main Level Area A Demo Floor Plan 0 16 24 32 8 SCALE: 1/8" = 1'-0" FLOOR PLANS TAG NOTE LEGEND TAG NOTE D201 REMOVE EXISTING WALL D202 REMOVE EXISTING WINDOW D203 REMOVE EXISTING DOOR AND DOOR FRAME D204 REMOVE EXISTING PARTITION WALL AND STRUCTURE D205 REMOVE EXISTING PLUMBING FIXTURES D206 REMOVE EXISTING FINISHES, INCLUDING BUT NOT LIMITED TO FLOOR FINISHES AND WALL COVERINGS, ETC D208 EXISTING STRUCTURE TO REMAIN INTACT, REF TO STRUCTURE DWGS D209 EXISTING WALL TO REMAIN D210 EXISTING DOOR TO REMAIN, REMOVE EXISTING DOOR HARDWARE D211 EXSITING WINDOW TO REMAIN D212 REMOVE EXISTING CASEWORK IN CLASSROOM D213 REMOVE EXISTING EXTERIOR FINISH AND EXSITING INSUALTION D227 REF MEP DWGS FOR WORK IN EXISTING MECHANICAL ROOM D228 REMOVE EXISTING FLOOR FINISH ON STAIR TREADS PEC APPROVED 9/11/2017 12:00:00 AM