Loading...
HomeMy WebLinkAboutPEC17-0031_PS1.02_1506638820.pdfPS2.01 1 PS2.021 PS2.02 2 PS2.01 4 1 PS3.01 24' - 0" 19 22 19' - 0" 2 PS3.01 2 3 4 5 6 7 8 9 10 A B C D 1 Level 3 SLOPE WEST STAIRS WEST STAIRS 21' - 3" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 3" 9' - 11" TYP. 2' - 4" TYP. TYP. TYP. 64' - 0" 19' - 9" 22' - 6" 19' - 9" 18' - 11" 24' - 8" 24' - 8" 24' - 8" 24' - 8" 24' - 8" 24' - 8" 24' - 11" 8' - 0" 4' - 0" 4' - 0" 8' - 0" 4' - 0" A201 A201 A205 A201 9' - 0" 19' - 0" A209 A209 A209 A211 A209 A209A209 X-1 R-1 (13,022 SF) A204 A20421' - 6" 18' - 4" 8223' - 6 5/8" 8222' - 3 7/8" A219 A219 A219 A219 A219 A219 A219 A218 A218A218 A218 A218 A218 A218A218 A218 1 PS3.03 2 PS3.03 3 PS3.03 EAST STAIRS A221 A214 A214 A207 A210 A206 A215 R-1 6 PS5.01 5 PS5.01 7 PS5.01 2% PS2.01 1 PS2.021 PS2.02 2 PS2.01 4 1 PS3.01 24' - 0" 19' - 0" 9' - 0" 19 22 2 PS3.01 2 3 4 5 6 7 8 9 10 A B C D 1 Level 4 SLOPE WEST STAIRS 21' - 3" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 0" 27' - 3" 9' - 11" TYP 2' - 4" 62' - 0" 19' - 9" 22' - 6" 19' - 9" 18' - 11" 24' - 8" 24' - 8" 24' - 8" 24' - 8" 24' - 8" 19' - 0" 5' - 0" 5' - 0" A215A215 A201 A201 A204 A211 A211 A211 A210 A207 A209 A209 A209 A209 A209 A209 20' CANTILEVER ROLLING GATE X-1 R-1 R-1 (13,022 SF) A201 A204 21' - 6" 212' - 10" 18' - 4" 8234' - 10 3/4" 8233' - 7 7/8" A219 A219 A219 A219 A219 A219 A219 A219 1 PS3.03 2 PS3.03 3 PS3.03 EAST STAIRS A215 A214 A214 A206 A221 5 PS5.01 8 PS5.01 2% 7' - 0" FLOOR PLAN GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. IN AREAS WITH FLOOR DRAINS, SLOPE CONCRETE SURFACE WITHIN 18" RADIUS AT 1/4" PER FOOT TOWARD FLOOR DRAIN, UNLESS OTHERWISE INDICATED. 3. ALL SPOT ELEVATIONS SHOWN ON THE FLOOR PLANS RELATE TO USGS ELEVATIONS. NOTIFY ARCHITECT IMMEDIATELY SHOULD CONDITIONS BE FOUND CONTRADICTORY TO THESE DRAWINGS. 4. ALL ANGLES SHOWN ON THE FLOOR PLANS ARE 90 DEGREES UNLESS OTHERWISE NOTED. 5. ALL DIMENSIONS ARE TO GRID LINE, FACE OF CONCRETE OR MASONRY, OR FACE OF GYPSUM BOARD, UNLESS OTHERWISE NOTED. 6. ALL FLOOR PLAN DIMENSIONS TO MASONRY ARE NOMINAL DIMENSIONS, UNLESS NOTED AS ACTUAL. Architecture Engineering Planning Interiors © , DLR Group inc., a Colorado corporation, ALL RIGHTS RESERVED LEGEND NOTES Revisions STAMP NORTH 56 Edwards Village Blvd Suite 210 Edwards, CO 816362 970-766-1740 20179/6/2017 5:04:31 PM C:\Users\ivan\Documents\1627.02.1 - RSES Parking Garage - CENTRAL_ivan.rvt 1627.02.1 Red Sandstone Elementary School Renovation + Parking Garage - Vail Potato Patch Block 2 Lot 8 SCHEMATIC DESIGN SET Levels 3 & 4 PS1.02 08/28/17 551 N Frontage Rd W Vail, CO 81657 1/8" = 1'-0" PS1.02 1 Level 3 1/8" = 1'-0" PS1.02 2 Level 4 0 16 24 32 8 SCALE: 1/8" = 1'-0" Tag Notes Legend Key Value Keynote Text A201 9' x 19' PARKING STALL A204 ELECTRIC CHARGING PARKING A205 COMPACT PARKING A206 ELECTRIC ENTRY GATE A207 ELECTRIC ENTRY GATE RECIEVER A209 STRUCTURAL COLUMN A210 TRAFFIC BOLLARD A211 TRAFFIC STRIPING A214 ROOF BELOW A215 PV PANELS A218 ALTERNATE #1 - PROVIDE FOUR (4) EQUALLY SPACED, RAISED DOMES THREE (3) NON-REFLECTIVE DOMES AND ONE (1) REFLECTIVE DOME AT EACH PARKING STRIPE ON ENTIRE PARKING LEVEL A219 ALTERNATE #2 - STEEL CORNER GUARDS AT ALL COLUMNS A221 EVERGREEN TREE R-1 STANDING SEAM METAL ROOF X-1 PRECAST EXPOSED CONCRETE, SCORED, NO COLOR ADDED PEC APPROVED 9/11/2017 12:00:00 AM