Loading...
HomeMy WebLinkAboutPEC17-0031_RSES + Parking Garage Exterior Light Fixtures_1498486620.pdfNote: Philips Lumec reserves the right to modify the above details to reflect changes in the cost of materials and/or production and/or design without prior notice.P27 > POLE AND BRACKET GUIDE ROUND STEEL POLE > SPR5 Specifications: Pole: made from a one-piece, 5” round (127 mm) tube of high-tensile carbon steel sealed by a rolled and flattened vertical weld seam and welded to both the top and bottom of a steel anchor plate. A 2” by 4 1/2” (51 by 114 mm) maintenance opening is complete with cover and copper ground lug. Base cover: square base cover made from two pieces of formed aluminum mechanically fastened to the base with stainless steel hardware. Finish: See page 142 for Finish details. Options: DE: Pole buried 5’ (1524 mm) in the ground (see page 133) LS: Provision for loudspeaker outlet (see page 132) PH7: Button-type photoelectric cell (specify operating voltage) PH8: Quarter-turn type photoelectric cell (specify operating voltage) DR: Duplex receptacle (120V line voltage only) GFI: DR with common ground fault interrupter (120V line voltage only) BA: Banner arm (see page 136) PS: Plant support (see page 137) MPL: Mid-pole luminaire Two-piece round decorative base cover: LBC1: Cast-aluminum B105: Cast-aluminum B50: Cast-aluminum Note: The recommended method for calculating EPA (Effective Projected Area) is in accordance with AASHTO 2001 standards: for three seconds, the pole is tested in wind gusts equivalent to the strongest winds on record over the past 50 years, and with a 50 pound load (22.7 kg) placed at 1 foot (305 mm) above its center. Base details Optional base covers Comes with 4 anchor bolts,8 nuts and 8 washers.BLN 3/4” B.C. from: 8‘‘ to 12 1/2‘‘ (203 to 324 mm)BLN 1” B.C. from: 8‘‘ to 12 7/8‘‘ (203 to 327 mm)Bolt Projection3 " (76 mm) (3/4" bolts3 1/2" (89 mm) (1" bolts)Bolt circle 12 1/2" (318 mm)9 5/8"(244 mm)12 3/4"(324 mm)Wireway 3 5/16" (84 mm)Bolt Projection3 " (76 mm) (3/4" bolts3 1/2" (89 mm) (1" bolts)Bolt circle 12 1/2" (318 mm)9 5/8"(244 mm)12 3/4"(324 mm)Wireway 3 5/16" (84 mm) LBC124 1/4"(616 mm)17 5/8"(443 mm)14 3/8"(365 mm)17" (432 mm) B105 B105Standard base cover CATALOG NOMINAL TENON WALL EPA RATING NUMBER HEIGHT SECTION THICKNESS WEIGHT 90 MPH 110 MPH 120 MPH 150 MPH ANCHOR BOLTS ft m in mm in mm lbs kg sq.ft sq.ft sq.ft sq.ft in mm SPR5C-14 14 4.27 5 127 0.150 3.8 133 61 26.73 18.07 15.22 9.71 3/4-20 19-508 SPR5J-14 14 4.27 5 127 0.180 4.6 154 70 30 21.84 18.42 11.8 3/4-20 19-508 SPR5V-14 14 4.27 5 127 0.250 6.4 201 91 30 30 25.56 16.47 3/4-20 19-508 SPR5C-15 15 4.57 5 127 0.150 3.8 141 64 24.44 16.49 13.87 8.83 3/4-20 19-508 SPR5J-15 15 4.57 5 127 0.180 4.6 163 74 29.52 19.99 16.86 10.77 3/4-20 19-508 SPR5V-15 15 4.57 5 127 0.250 6.4 214 97 30 27.82 23.5 15.12 3/4-20 19-508 SPR5C-16 16 4.88 5 127 0.150 3.8 148 67 22.49 15.13 12.73 8.07 3/4-20 19-508 SPR5J-16 16 4.88 5 127 0.180 4.6 172 78 27.23 18.42 15.51 9.89 3/4-20 19-508 SPR5V-16 16 4.88 5 127 0.250 6.4 227 103 30 25.74 21.74 13.99 3/4-20 19-508 SPR5C-18 18 5.49 5 127 0.150 3.8 163 74 18.56 12.39 10.38 6.51 1-36 25-914 SPR5J-18 18 5.49 5 127 0.180 4.6 191 87 22.63 15.22 12.8 8.1 1-36 25-914 SPR5V-18 18 5.49 5 127 0.250 6.4 252 115 30 21.51 18.15 11.61 1-36 25-914 SPR5C-20 20 6.10 5 127 0.150 3.8 178 81 15.37 10.15 8.48 5.24 1-36 25-914 SPR5J-20 20 6.10 5 127 0.180 4.6 208 94 18.91 12.61 10.57 6.61 1-36 25-914 SPR5V-20 20 6.10 5 127 0.250 6.4 277 126 26.74 18.09 15.22 9.69 1-36 25-914 SPR5C-22 22 6.71 5 127 0.150 3.8 193 88 12.72 8.27 6.86 4.17 1-36 25-914 SPR5V-22 22 6.71 5 127 0.250 6.4 303 138 22.68 15.24 12.8 8.07 1-36 25-914 SPR5V-25 25 7.62 5 127 0.250 6.4 340 154 17.72 11.74 9.81 6.08 1-36 25-914 SPR5V-30 30 9.14 5 127 0.250 6.4 404 183 11.41 7.25 5.96 3.48 1-36 25-914 LBC124 1/4"(616 mm)16" (406 mm)29"(737 mm)17" (432 mm) B50 One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 03/29/17 Page 1 of 6 D-SeriesSize 0LED Area Luminaire Specifications Catalog Number Notes Type EPA:0.95 ft2 (.09 m2) Length:26” (66.0 cm) Width:13” (33.0 cm) Height:7” (17.8 cm) Weight (max):16 lbs(7.25 kg) Hit the Tab key or mouse over the page to see all interactive elements. L H W Ordering Information EXAMPLE: DSX0 LED 40C 1000 40K T3M MVOLT SPA DDBXD DSX0 LED Series LEDs Drive current Color temperature Distribution Voltage Mounting DSX0 LED Forward optics 20C 20 LEDs (one engine) 40C 40 LEDs (two engines) Rotated optics1 30C 30 LEDs (one engine) 530 530 mA 700 700 mA 1000 1000 mA (1 A) 30K 3000 K 40K 4000 K 50K 5000 K AMBPC Amber phosphor converted2 T1S Type I short T2S Type II short T2M Type II medium T3S Type III short T3M Type III medium T4M Type IV medium TFTM Forward throw medium T5VS Type V very short T5S Type V short T5M Type V medium T5W Type V wide BLC Backlight control2,3 LCCO Left corner cutoff2,3 RCCO Right corner cutoff2,3 MVOLT 4 120 4 208 4 240 4 277 4 347 5 480 5 Shipped included SPA Square pole mounting RPA Round pole mounting WBA Wall bracket SPUMBA Square pole universal mounting adaptor 6 RPUMBA Round pole universal mounting adaptor 6 Shipped separately KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish)7 Control options Other options Finish (required) Shipped installed PER NEMA twist-lock receptacle only (no controls) 8 PER5 Five-wire receptacle only (no controls) 8,9 PER7 Seven-wire receptacle only (no controls) 8,9 DMG 0-10V dimming extend out back of honsing for external control (no controls) 10 DCR Dimmable and controllable via ROAM® (no controls) 11 PIR Bi-level, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 5fc 12 PIRH Bi-level, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 5fc 12 PIR1FC3V Bi-level, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 1fc12 PIRH1FC3V Bi-level, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 1fc12 BL30 Bi-level switched dimming, 30% 13,14 BL50 Bi-level switched dimming, 50% 13,15 PNMTDD3 Part night, dim till dawn 15 PNMT5D3 Part night, dim 5 hrs 15 PNMT6D3 Part night, dim 6 hrs 15 PNMT7D3 Part night, dim 7 hrs 15 FAO Field adjustable output16 Shipped installed HS House-side shield 17 SF Single fuse (120, 277, 347V) 18 DF Double fuse (208, 240, 480V) 18 L90 Left rotated optics 1 R90 Right rotated optics 1 DDL Diffused drop lens17 BS Bird spikes DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and system-level interoperability. • All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency • This luminaire is A+ Certified when ordered with DTL® controls marked by a shaded background. DTL DLL equipped luminaires meet the A+ specification for luminaire to photocontrol interoperability1 • This luminaire is part of an A+ Certified solution for ROAM®2 or XPoint™ Wireless control networks, providing out-of-the-box control compatibility with simple commissioning, when ordered with drivers and control options marked by a shaded background1 To learn more about A+, visit www.acuitybrands.com/aplus. 1. See ordering tree for details. 2. A+ Certified Solutions for ROAM require the order of one ROAM node per luminaire. Sold Separately: Link to Roam; Link to DTL DLLA+ Capable options indicated by this color background. One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 03/29/17 Page 2 of 6 Visit Lithonia Lighting’s POLES CENTRAL to see our wide selection of poles, accessories and educational tools. *Round pole top must be 3.25” O.D. minimum. **For round pole mounting (RPA) only. DSX0 shares a unique drilling pattern with the AERIS™ family. Specify this drilling pattern when specifying poles, per the table below. DM19AS Single unit DM29AS 2 at 90° * DM28AS 2 at 180° DM39AS 3 at 90° * DM49AS 4 at 90° * DM32AS 3 at 120° ** Example: SSA 20 4C DM19AS DDBXD Tenon O.D.Single Unit 2 at 180°2 at 90°3 at 120°3 at 90°4 at 90° 2-3/8”AST20-190 AST20-280 AST20-290 AST20-320 AST20-390 AST20-490 2-7/8”AST25-190 AST25-280 AST25-290 AST25-320 AST25-390 AST25-490 4”AST35-190 AST35-280 AST35-290 AST35-320 AST35-390 AST35-490 Tenon Mounting Slipfitter ** Drilling Top of Pole 0.563” 2.650” 1.325”0.400”(2 PLCS) Template #8 To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Area Size 0 homepage. Photometric Diagrams Isofootcandle plots for the DSX0 LED 40C 1000 40K. Distances are in units of mounting height (20’).Test No. LTL23456P25 tested in accordance with IESNA LM-79-08.Test No. LTL23451P25 tested in accordance with IESNA LM-79-08.Test No. LTL23422P25 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 Test No. LTL23457P25 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5MT4M HST3MT1S LEGEND 0.1 fc 0.5 fc 1.0 fc Ordering Information NOTES1 30 LEDs (30C option) and rotated options (L90 or R90) only available together. 2 AMBPC is not available with BLC, LLCO or RCCO. 3 Not available with HS or DDL.4 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). Specify 120V, 208V, 240V or 277V options only when ordering with fusing (SF, DF options). 5 Not available with single board, 530mA product (20C 530 or 30C 530). Not available with BL30, BL50 or PNMT options. 6 Existing drilled pole only. Available as a separate combination accessory; for retrofit use only: PUMBA (finish) U; 1.5 G vibration load rating per ANCI C136.31. 7 Must order fixture with SPA mounting. Must be ordered as a separate accessory; see Accessories information. For use with 2-3/8” mast arm (not included). 8 Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap be order for correct operation when photocontrol is present.9 If ROAM® node required, it must be ordered and shipped as a separate line item from Acuity Brands Controls. Not available with DCR. Node with integral dimming.10 DMG option for 347V or 480V requires 1000mA. 11 Specifies a ROAM® enabled luminaire with 0-10V dimming capability; PER option required. Additional hardware and services required for ROAM® deployment; must be purchased separately. Call 1-800-442-6745 or email: sales@roamservices.net. N/A with PER5, PER7, BL30, BL50 or PNMT options. Node without integral dimming. Mvolt only. Not available with 347V and 480V. Not available with PIRH1FC3V.12 PIR and PIR1FC3V specify the SensorSwitch SBGR-10-ODP control; PIRH and PIRH1FC3V specify the SensorSwitch SBGR-6-ODP control; see Outdoor Control Technical Guide for details. Dimming driver standard. Ambient sensor disabled when ordered with DCR. Separate on/off required. Not available with PNMT options. PIR and PIRH options are used with PER5 and PER7, additional leads from receptacle are terminated and non-functioning. When PIR and PIRH options are selected with DCR, old style ROAM node must be used or PIRH and PIRH will not function correctly.13 Requires an additional switched circuit. 14 Dimming driver standard. MVOLT only. Not available with 347V, 480V, DCR, PER5, PER7 or PNMT options. Not available with PIR1FC3V and PIRH1FC3V.15 Dimming driver standard. MVOLT only. Not available with 347V, 480V, DCR, PER5, PER7, BL30 or BL50. Not available with PIR1FC3V and PIRH1FC3V. Separate on/off required.16 Dimming driver standard. Not available with PER5, PER7, DMG, DCR, BL30, BL50, PNMT, PIR, PIRH, PIR1FC3V and PIRH1FC3V.17 Not available with BLC, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information. 18 Single fuse (SF) requires 120V, 277V or 347V. Double fuse (DF) requires 208V, 240V or 480V. 19 Requires luminaire to be specified with PER option. Ordered and shipped as a separate line item from Acuity Brands Controls. 20 For retrofit use only.AccessoriesOrdered and shipped separately. Controls & Shields DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 19 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 19 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 19 DSHORT SBK U Shorting cap 19 DSX0EGS DDBXD U External glare shield DSX0HS 20C U House-side shield for 20 LED unit 17 DSX0HS 30C U House-side shield for 30 LED unit 17 DSX0HS 40C U House-side shield for 40 LED unit 17 DSX0DDL U Diffused drop lens (polycarbonate) 17 PUMBA DDBXD U*Square and round pole universal mount-ing bracket adaptor (specify finish)20 KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish) 7 For more control options, visit DTL and ROAM online. 26.06 5.96 TYP. 7.30 18.76 .45 TYP. 6.53 TYP. .32 R.09 .19.13 3.30 .13 .14 THRU 12.43 4.31 6.53 .50 78° 59° .38 12.05.30 SEE DETAIL A4 PLCS. SCALE 2:1ADETAIL C 90.0090.00 90.0090.00 External Glare Shield One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 03/29/17 Page 3 of 6 Performance Data Current (A) Number of LEDs Drive Current (mA)System Watts 120 208 240 277 347 480 20C 530 35 0.34 0.22 0.21 0.20 ---- 700 45 0.47 0.28 0.24 0.22 0.18 0.14 1000 72 0.76 0.45 0.39 0.36 0.36 0.26 30C 530 52 0.51 0.31 0.28 0.25 ---- 700 70 0.72 0.43 0.37 0.34 0.25 0.19 1000 104 1.11 0.64 0.56 0.49 0.47 0.34 40C 530 68 0.71 0.41 0.36 0.33 0.25 0.19 700 91 0.94 0.55 0.48 0.42 0.33 0.24 1000 138 1.45 0.84 0.73 0.64 0.69 0.50 Electrical Load Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers Ambient Lumen Multiplier 0°C 32°F 1.02 10°C 50°F 1.01 20°C 68°F 1.00 25°C 77°F 1.00 30°C 86°F 1.00 40°C 104°F 0.99 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 0 25,000 50,000 100,000 Lumen Maintenance Factor DSX0 LED 20C 1000 1 0.98 0.96 0.93 DSX0 LED 40C 1000 1 0.98 0.95 0.90 DSX0 LED 40C 700 1 0.99 0.99 0.99 One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 03/29/17 Page 4 of 6 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Forward Optics LEDs Drive Current (mA) System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) AMBPC (Amber Phosphor Converted) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 20C (20 LEDs) 530 mA 35 W T1S 4,079 1 0 1 117 4,380 1 0 1 125 4,408 1 0 1 126 2,541 1 0 1 73 T2S 4,206 1 0 1 120 4,516 1 0 1 129 4,544 1 0 1 130 2,589 1 0 1 74 T2M 4,109 1 0 1 117 4,413 1 0 1 126 4,440 1 0 1 127 2,539 1 0 1 73 T3S 4,104 1 0 1 117 4,407 1 0 1 126 4,435 1 0 1 127 2,558 1 0 1 73 T3M 4,142 1 0 1 118 4,447 1 0 1 127 4,475 1 0 1 128 2,583 1 0 1 74 T4M 4,198 1 0 1 120 4,508 1 0 1 129 4,536 1 0 1 130 2,570 1 0 1 73 TFTM 4,135 1 0 1 118 4,440 1 0 2 127 4,468 1 0 2 128 2,540 1 0 1 73 T5VS 4,368 2 0 0 125 4,691 2 0 0 134 4,720 2 0 0 135 2,650 1 0 0 76 T5S 4,401 2 0 2 126 4,725 2 0 0 135 4,755 2 0 0 136 2,690 1 0 0 77 T5M 4,408 2 0 1 126 4,734 3 0 1 135 4,763 3 0 1 136 2,658 2 0 0 76 T5W 4,344 3 0 1 124 4,664 3 0 1 133 4,693 3 0 1 134 2,663 2 0 1 76 BLC 3,071 1 0 1 88 3,297 1 0 1 94 3,318 1 0 1 95 LCCO 2,983 1 0 1 85 3,204 1 0 1 92 3,224 1 0 1 92 RCCO 2,983 1 0 1 85 3,204 1 0 1 92 3,224 1 0 1 92 700 mA 45 W T1S 5,181 1 0 1 115 5,563 1 0 1 124 5,598 1 0 1 124 3,144 1 0 1 70 T2S 5,342 1 0 1 119 5,736 1 0 1 127 5,772 1 0 1 128 3,203 1 0 1 71 T2M 5,219 1 0 1 116 5,605 1 0 1 125 5,640 1 0 1 125 3,141 1 0 1 70 T3S 5,213 1 0 1 116 5,598 1 0 1 124 5,633 1 0 1 125 3,165 1 0 1 70 T3M 5,260 1 0 1 117 5,649 1 0 2 126 5,684 1 0 2 126 3,196 1 0 1 71 T4M 5,332 1 0 1 118 5,725 1 0 2 127 5,761 1 0 2 128 3,179 1 0 1 71 TFTM 5,252 1 0 2 117 5,640 1 0 2 125 5,675 1 0 2 126 3,143 1 0 1 70 T5VS 5,548 2 0 0 123 5,958 2 0 0 132 5,995 2 0 0 133 3,278 2 0 0 73 T5S 5,589 2 0 0 124 6,002 2 0 0 133 6,039 2 0 0 134 3,328 2 0 0 74 T5M 5,599 3 0 1 124 6,012 3 0 1 134 6,050 3 0 1 134 3,288 2 0 1 73 T5W 5,517 3 0 1 123 5,924 3 0 1 132 5,961 3 0 1 132 3,295 2 0 1 73 BLC 3,909 1 0 1 87 4,198 1 0 1 93 4,224 1 0 1 94 LCCO 3,798 1 0 1 84 4,078 1 0 1 91 4,104 1 0 1 91 RCCO 3,798 1 0 1 84 4,078 1 0 1 91 4,104 1 0 1 91 1000 mA 72 W T1S 7,085 1 0 1 98 7,608 2 0 2 106 7,656 2 0 2 106 T2S 7,305 1 0 1 101 7,845 2 0 2 109 7,894 2 0 2 110 T2M 7,138 1 0 2 99 7,665 2 0 2 106 7,713 2 0 2 107 T3S 7,129 1 0 1 99 7,656 2 0 2 106 7,704 2 0 2 107 T3M 7,194 1 0 2 100 7,725 2 0 2 107 7,773 2 0 2 108 T4M 7,292 1 0 2 101 7,830 2 0 2 109 7,879 2 0 2 109 TFTM 7,183 1 0 2 100 7,713 1 0 2 107 7,761 1 0 2 108 T5VS 7,588 2 0 0 105 8,148 3 0 0 113 8,199 3 0 0 114 T5S 7,644 2 0 0 106 8,208 2 0 0 114 8,259 2 0 0 115 T5M 7,657 3 0 1 106 8,222 3 0 1 114 8,274 3 0 1 115 T5W 7,545 3 0 1 105 8,102 3 0 2 113 8,153 3 0 2 113 BLC 5,162 1 0 1 72 5,543 1 0 2 77 5,578 1 0 1 77 LCCO 5,015 1 0 2 70 5,386 1 0 2 75 5,419 1 0 2 75 RCCO 5,015 1 0 2 70 5,386 1 0 2 75 5,419 1 0 2 75 Performance Data Lumen Output One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 03/29/17 Page 5 of 6 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Forward Optics LEDs Drive Current (mA) System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) AMBPC (Amber Phosphor Converted) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 40C (40 LEDs) 530 mA 68 W T1S 7,926 2 0 2 117 8,511 2 0 2 125 8,564 2 0 2 126 4,878 1 0 1 72 T2S 8,172 2 0 2 120 8,775 2 0 2 129 8,830 2 0 2 130 4,969 1 0 1 73 T2M 7,985 2 0 2 117 8,574 2 0 2 126 8,628 2 0 2 127 4,874 1 0 1 72 T3S 7,975 1 0 2 117 8,564 2 0 2 126 8,617 2 0 2 127 4,910 1 0 1 72 T3M 8,047 2 0 2 118 8,642 2 0 2 127 8,696 2 0 2 128 4,958 1 0 2 73 T4M 8,157 1 0 2 120 8,759 2 0 2 129 8,813 2 0 2 130 4,932 1 0 2 73 TFTM 8,035 1 0 2 118 8,628 2 0 2 127 8,682 2 0 2 128 4,876 1 0 2 72 T5VS 8,488 2 0 0 125 9,115 3 0 0 134 9,172 3 0 0 135 5,086 2 0 0 75 T5S 8,550 2 0 0 126 9,182 3 0 1 135 9,239 3 0 1 136 5,163 2 0 0 76 T5M 8,565 3 0 1 126 9,198 3 0 2 135 9,255 3 0 2 136 5,102 3 0 1 75 T5W 8,440 3 0 2 124 9,063 3 0 2 133 9,120 3 0 2 134 5,112 3 0 1 75 BLC 6,142 1 0 2 90 6,595 1 0 2 97 6,636 1 0 2 98 LCCO 5,967 1 0 2 88 6,407 1 0 2 94 6,447 1 0 2 95 RCCO 5,967 1 0 2 88 6,407 1 0 2 94 6,447 1 0 2 95 700 mA 91 W T1S 10,066 2 0 2 111 10,810 2 0 2 119 10,877 2 0 2 120 6,206 2 0 2 68 T2S 10,379 2 0 2 114 11,145 2 0 2 122 11,215 2 0 2 123 6,322 2 0 2 69 T2M 10,141 2 0 2 111 10,890 2 0 2 120 10,958 2 0 2 120 6,201 2 0 2 68 T3S 10,129 2 0 2 111 10,877 2 0 2 120 10,945 2 0 2 120 6,247 1 0 2 69 T3M 10,221 2 0 2 112 10,975 2 0 2 121 11,044 2 0 2 121 6,308 2 0 2 69 T4M 10,359 2 0 2 114 11,124 2 0 2 122 11,194 2 0 2 123 6,275 1 0 2 69 TFTM 10,205 2 0 2 112 10,958 2 0 3 120 11,027 2 0 3 121 6,203 1 0 2 68 T5VS 10,781 3 0 0 118 11,576 3 0 1 127 11,649 3 0 1 128 6,569 2 0 0 72 T5S 10,860 3 0 1 119 11,662 3 0 1 128 11,734 3 0 1 129 6,569 2 0 0 72 T5M 10,879 3 0 2 120 11,682 3 0 2 128 11,755 3 0 2 129 6,491 3 0 1 71 T5W 10,719 3 0 2 118 11,511 4 0 2 126 11,583 4 0 2 127 6,504 3 0 2 71 BLC 7,819 1 0 2 86 8,396 1 0 2 92 8,448 1 0 2 93 LCCO 7,596 1 0 2 83 8,157 1 0 2 90 8,208 1 0 2 90 RCCCO 7,596 1 0 2 83 8,157 1 0 2 90 8,208 1 0 2 90 1000 mA 138 W T1S 13,767 2 0 2 100 14,783 3 0 3 107 14,876 3 0 3 108 T2S 14,194 2 0 2 103 15,242 3 0 3 110 15,338 3 0 3 111 T2M 13,869 2 0 2 101 14,893 3 0 3 108 14,986 3 0 3 109 T3S 13,852 2 0 2 100 14,875 2 0 2 108 14,968 2 0 2 108 T3M 13,978 2 0 2 101 15,010 3 0 3 109 15,104 3 0 3 109 T4M 14,168 2 0 2 103 15,214 3 0 3 110 15,309 3 0 3 111 TFTM 13,956 2 0 3 101 14,987 2 0 3 109 15,080 2 0 3 109 T5VS 14,744 3 0 1 107 15,832 3 0 1 115 15,931 4 0 1 115 T5S 14,852 3 0 1 108 15,948 3 0 1 116 16,048 3 0 1 116 T5M 14,878 4 0 2 108 15,976 4 0 2 116 16,076 4 0 2 116 T5W 14,660 4 0 2 106 15,742 4 0 2 114 15,840 4 0 2 115 BLC 10,325 1 0 2 75 11,087 1 0 2 80 11,156 1 0 2 81 LCCO 10,031 2 0 2 73 10,771 2 0 3 78 10,839 2 0 3 79 RCCO 10,031 2 0 2 73 10,771 2 0 3 78 10,839 2 0 3 79 Performance Data Lumen Output One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 03/29/17 Page 6 of 6 FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series Size 0 reflects the embedded high performance LED technology. It is ideal for many commercial and municipal applications, such as parking lots, plazas, campuses, and pedestrian areas. CONSTRUCTION Single-piece die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. Modular design allows for ease of maintenance and future light engine upgrades. The LED driver is mounted in direct contact with the casting to promote low operating temperature and long life. Housing is completely sealed against moisture and environmental contaminants (IP65). Low EPA (0.95 ft2) for optimized pole wind loading. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Available in both textured and non-textured finishes. OPTICS Precision-molded proprietary acrylic lenses are engineered for superior area lighting distribution, uniformity, and pole spacing. Light engines are available in 3000 K, 4000 K or 5000 K (70 CRI) or optional 3000 K (70 minimum CRI) or 5000 K (70 CRI) configurations. The D-Series Size 0 has zero uplight and qualifies as a Nighttime FriendlyTM product, meaning it is consistent with the LEED® and Green GlobesTM criteria for eliminating wasteful uplight. ELECTRICAL Light engine(s) configurations consist of 20, 30 or 40 high-efficacy LEDs mounted to metal-core circuit boards to maximize heat dissipation and promote long life (up to L99/100,000 hours at 25°C). Class 1 electronic drivers are designed to have a power factor >90%, THD <20%, and an expected life of 100,000 hours with <1% failure rate. Easily serviceable 10kV or 6kV surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). INSTALLATION Included mounting block and integral arm facilitate quick and easy installation. Stainless steel bolts fasten the mounting block securely to poles and walls, enabling the D-Series Size 0 to withstand up to a 3.0 G vibration load rating per ANSI C136.31. The D-Series Size 0 utilizes the AERISTM series pole drilling pattern (template #8). Optional terminal block and NEMA photocontrol receptacle are also available. LISTINGS UL Listed for wet locations. Light engines are IP66 rated; luminaire is IP65 rated. Rated for -40°C minimum ambient. U.S. Patent No. D672,492 S. International patent pending. DesignLights Consortium® (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights.org to confirm which versions are qualified. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. L90 and R90 Rotated Optics LEDs Drive Current (mA) System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) AMBPC (Amber Phosphor Converted) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 30C (30 LEDs) 530 mA 52 W T1S 6,130 2 0 2 118 6,583 2 0 2 127 6,624 2 0 2 127 3,841 2 0 2 74 T2S 6,321 2 0 2 122 6,787 2 0 2 131 6,830 3 0 3 131 3,912 2 0 2 75 T2M 6,176 2 0 2 119 6,632 3 0 3 128 6,673 3 0 3 128 3,837 2 0 2 74 T3S 6,168 2 0 2 119 6,624 3 0 3 127 6,665 3 0 3 128 3,866 2 0 2 74 T3M 6,224 3 0 3 120 6,684 3 0 3 129 6,726 3 0 3 129 3,904 2 0 2 75 T4M 6,309 3 0 3 121 6,775 3 0 3 130 6,817 3 0 3 131 3,884 2 0 2 75 TFTM 6,215 3 0 3 120 6,673 3 0 3 128 6,715 3 0 3 129 3,839 2 0 2 74 T5VS 6,565 2 0 0 126 7,050 2 0 0 136 7,094 2 0 0 136 4,005 2 0 0 77 T5S 6,613 2 0 0 127 7,102 2 0 0 137 7,146 2 0 0 137 4,065 2 0 0 78 T5M 6,625 3 0 1 127 7,114 3 0 1 137 7,159 3 0 1 138 4,017 2 0 1 77 T5W 6,528 3 0 1 126 7,010 3 0 2 135 7,054 3 0 2 136 4,025 3 0 1 77 BLC 4,747 2 0 2 91 5,098 2 0 2 98 5,130 2 0 2 99 LCCO 4,612 1 0 2 89 4,953 1 0 2 95 4,984 1 0 2 96 RCCO 4,612 1 0 2 89 4,953 1 0 2 95 4,984 1 0 2 96 700 mA 70 W T1S 7,786 2 0 2 111 8,361 3 0 3 119 8,413 3 0 3 120 4,783 2 0 2 68 T2S 8,028 2 0 2 115 8,620 3 0 3 123 8,674 3 0 3 124 4,873 2 0 2 70 T2M 7,844 3 0 3 112 8,423 3 0 3 120 8,476 3 0 3 121 4,779 2 0 2 68 T3S 7,834 3 0 3 112 8,413 3 0 3 120 8,465 3 0 3 121 4,815 2 0 2 69 T3M 7,905 3 0 3 113 8,489 3 0 3 121 8,542 3 0 3 122 4,862 3 0 3 69 T4M 8,013 3 0 3 114 8,604 3 0 3 123 8,658 3 0 3 124 4,837 3 0 3 69 TFTM 7,893 3 0 3 113 8,476 3 0 3 121 8,529 3 0 3 122 4,781 3 0 3 68 T5VS 8,338 2 0 0 119 8,954 3 0 0 128 9,010 3 0 0 129 4,988 2 0 0 71 T5S 8,400 2 0 0 120 9,020 3 0 1 129 9,076 3 0 1 130 5,063 2 0 0 72 T5M 8,414 3 0 1 120 9,036 3 0 2 129 9,092 3 0 2 130 5,003 3 0 1 71 T5W 8,291 3 0 2 118 8,903 3 0 2 127 8,959 3 0 2 128 5,013 3 0 1 72 BLC 6,044 2 0 2 86 6,490 3 0 3 93 6,530 3 0 3 93 LCCO 5,872 1 0 2 84 6,305 1 0 2 90 6,345 1 0 2 91 RCCO 5,872 1 0 2 84 6,305 1 0 2 90 6,345 1 0 2 91 1000 mA 104 W T1S 10,648 3 0 3 102 11,434 3 0 3 110 11,506 3 0 3 111 T2S 10,979 3 0 3 106 11,789 3 0 3 113 11,863 3 0 3 114 T2M 10,727 3 0 3 103 11,519 3 0 3 111 11,591 3 0 3 111 T3S 10,714 3 0 3 103 11,505 3 0 3 111 11,577 3 0 3 111 T3M 10,812 3 0 3 104 11,610 4 0 4 112 11,682 4 0 4 112 T4M 10,958 3 0 3 105 11,767 3 0 3 113 11,841 3 0 3 114 TFTM 10,795 3 0 3 104 11,592 3 0 3 111 11,664 4 0 4 112 T5VS 11,404 3 0 0 110 12,245 3 0 1 118 12,322 3 0 1 118 T5S 11,487 3 0 1 110 12,336 3 0 1 119 12,413 3 0 1 119 T5M 11,508 3 0 2 111 12,357 4 0 2 119 12,434 4 0 2 120 T5W 11,339 4 0 2 109 12,176 4 0 2 117 12,252 4 0 2 118 BLC 7,981 3 0 3 77 8,570 3 0 3 82 8,624 3 0 3 83 LCCO 7754 1 0 2 75 8326 2 0 2 80 8378 2 0 2 81 RCCO 7754 1 0 2 75 8326 2 0 2 80 8378 2 0 2 81 Performance Data T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting † See http://lighting.cree.com/warranty for warranty terms T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Rev. Date: V2 07/28/2016 Cree Edge™ Series LED Security Wall Pack Luminaire Ordering Information Example: SEC-EDG-2M-WM-06-E-UL-SV-700 SEC-EDG WM E Product Optic Mounting LED Count (x10)Series Voltage Color Options Drive Current Options SEC-EDG 2MType II Medium 2MBType II Medium w/BLS 2SType II Short 2SBType II Short w/BLS 3MType III Medium 3MBType III Medium w/BLS 4MType IV Medium 4MBType IV Medium w/BLS WMWall Mount 0204 06 08 1012 E ULUniversal120-277V UHUniversal347-480V 34347V BKBlack BZBronze SVSilver WHWhite 350350mA 525525mA-Available with 20-80 LEDs700700mA-Available with 20-60 LEDs DIM 0-10V Dimming -Control by others -Refer to Dimming spec sheet for details -Can't exceed specified drive current F Fuse -Refer to ML spec sheet for availability with ML options -Available with UL voltage only -When code dictates fusing, use time delay fuse ML Multi-Level -Refer to ML spec sheet for details -Intended for downlight applications of 0° tilt P Photocell -Refer to ML spec sheet for availability with ML options -Must specify UL or 34 voltage PML Programmable Multi-Level -Refer to PML spec sheet for details -Intended for downlight applications of 0° tilt40K 4000K Color Temperature -Minimum 70 CRI -Color temperature per luminaire Product Description The Cree Edge™ wall mount luminaire has a slim, low profile design. The luminaire end caps are made from rugged die cast aluminum with integral, weathertight LED driver compartments and high performance aluminum heat sinks specifically designed for LED applications. Housing is rugged aluminum. Includes a lightweight mounting box for installation over standard and mud ring single gang J-Boxes. Secures to wall with four 3/16" (5mm) screws (by others). Conduit entry from top, bottom, sides and rear. Allows mounting for uplight or downlight. Designed and approved for easy through-wiring. Includes leaf/debris guard. Applications: General area and security lighting Accessories Field-Installed Bird Spikes XA-BRDSPK Hand-Held Remote XA-SENSREM - For successful implementation of the programmable multi-level option, a minimum of one hand-held remote is required Patented NanoOptic® Product Technology Made in the U.S.A. of U.S. and imported parts CRI: Minimum 70 CRI CCT: 4000K (+/- 300K), 5700K (+/- 500K) standard Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish Performance Summary LED Count (x10)Dim. "A"Weight 02 9.9" (251mm)20 lbs. (9.1kg) 04 11.9" (303mm)22 lbs. (10.0kg) 06 13.9" (353mm)25 lbs. (11.3kg) 08 15.9" (404mm)27 lbs. (12.2kg) 10 17.9" (455mm)31 lbs. (14.1kg) 12 19.9" (505mm)32 lbs. (14.5kg) “A” 18.3"(464mm) 4.1"(104mm) T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Product Specifications CONSTRUCTION & MATERIALS • Slim, low profile design • Luminaire sides are rugged die cast aluminum with integral, weathertight LED driver compartment and high performance aluminum heat sinks specifically designed for LED applications • Housing is rugged aluminum • Furnished with low copper, light weight mounting box designed for installation over standard and mud ring single gang J-Boxes • Luminaire can also be direct mounted to a wall and surface wired • Secures to wall with four 3/16" (5mm) screws (by others) • Conduit entry from top, bottom, sides, and rear • Allows mounting for uplight or downlight • Designed and approved for easy through-wiring • Includes leaf/debris guard • Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze, silver and white are available • Weight: See Dimensions and Weight Chart on page 1 ELECTRICAL SYSTEM • Input Voltage: 120–277V or 347–480V, 50/60Hz, Class 1 drivers • Power Factor: > 0.9 at full load • Total Harmonic Distortion: < 20% at full load • Integral weathertight J-Box with leads (wire nuts) for easy power hook up • Integral 10kV surge suppression protection standard • To address inrush current, slow blow fuse or type C/D breaker should be used • Maximum 10V Source Current: 20 LED (350mA): 10mA; 20LED (525 & 700 mA) and 40-120 LED: 0.15mA REGULATORY & VOLUNTARY QUALIFICATIONS • cULus Listed • Suitable for wet locations • Meets FCC Part 15 standards for conducted and radiated emissions • Enclosure rated IP66 per IEC 60529 when ordered without P, PML or ML options • 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 • Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 • DLC qualified. Exceptions apply when ordered with full backlight control. Please refer to www.designlights.org/QPL for most current information • Dark Sky Friendly, IDA Approved. Please refer to www.darksky.org/ for most current information • Meets Buy American requirements within ARRA Cree Edge™ LED Security Wall Pack Luminaire Electrical Data* LED Count (x10) System Watts120-480V Total Current 120V 208V 240V 277V 347V 480V 350mA 02 25 0.21 0.13 0.11 0.10 0.08 0.07 04 46 0.36 0.23 0.21 0.20 0.15 0.12 06 66 0.52 0.31 0.28 0.26 0.20 0.15 08 90 0.75 0.44 0.38 0.34 0.26 0.20 10 110 0.92 0.53 0.47 0.41 0.32 0.24 12 130 1.10 0.63 0.55 0.48 0.38 0.28 525mA 02 37 0.30 0.19 0.17 0.16 0.12 0.10 04 70 0.58 0.34 0.31 0.28 0.21 0.16 06 101 0.84 0.49 0.43 0.38 0.30 0.22 08 133 1.13 0.66 0.58 0.51 0.39 0.28 700mA 02 50 0.41 0.25 0.22 0.20 0.15 0.12 04 93 0.78 0.46 0.40 0.36 0.27 0.20 06 134 1.14 0.65 0.57 0.50 0.39 0.29 * Electrical data at 25˚C (77˚F) Recommended Cree Edge™ Series Lumen Maintenance Factors (LMF)1 Ambient InitialLMF 25K hrProjected2 LMF 50K hrProjected2 LMF 75K hrCalculated3 LMF 100K hrCalculated3 LMF 5˚C (41˚F)1.04 0.99 0.97 0.95 0.93 10˚C (50˚F)1.03 0.98 0.96 0.94 0.92 15˚C (59˚F)1.02 0.97 0.95 0.93 0.91 20˚C (68˚F)1.01 0.96 0.94 0.92 0.90 25˚C (77˚F)1.00 0.95 0.93 0.91 0.89 1 Lumen maintenance values at 25˚C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/wall-mount/cree-edge-series-5 Cree Edge™ LED Security Wall Pack Luminaire 1762 3525 5287 7049 120˚120˚ 90˚90˚ 60˚60˚ 30˚30º 150˚150˚ Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 75˚ 20'20' 20' 20' 40'40' 40' 40' 6.1 0m 6.1 12.2 0m 6.16.1 12.212.2 18.318.3 0' 0' 12.2 60' Position of vertical planeof maximum candlepower. 521.5.2.1 CURB LINE 60' * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf 2M Type II Medium Distribution LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 2,138 B1 U0 G1 2,220 B1 U0 G1 04 4,276 B1 U0 G1 4,440 B1 U0 G1 06 6,340 B2 U0 G2 6,584 B2 U0 G2 08 8,454 B2 U0 G2 8,779 B2 U0 G2 10 10,542 B3 U0 G3 10,947 B3 U0 G3 12 12,650 B3 U0 G3 13,137 B3 U0 G3 525mA 02 2,993 B1 U0 G1 3,108 B1 U0 G1 04 5,986 B2 U0 G2 6,216 B2 U0 G2 06 8,876 B2 U0 G2 9,218 B2 U0 G2 08 11,835 B3 U0 G3 12,290 B3 U0 G3 700mA 02 3,656 B1 U0 G1 3,796 B1 U0 G1 04 7,311 B2 U0 G2 7,593 B2 U0 G2 06 10,842 B3 U0 G3 11,259 B3 U0 G3 ITL Test Report #: 79174SEC-EDG-2M-**-06-E-UL-700-40KInitial Delivered Lumens: 11,128 SEC-EDG-2M-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 11,835Initial FC at grade 1712 5136 6848 3424 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 120˚120˚ 90˚90˚ 60˚60˚ 30˚ 150˚150˚ CSA Test Report #: 6447ARE-EDG-2MB-**-06-E-UL-700-40KInitial Delivered Lumens: 7,953 70˚ 20'20' 20' 20' 40'40' 40' 40' 6.1 0m 6.1 12.2 0m 6.16.1 12.212.2 18.318.3 0' 0' 12.2 60'60' Position of vertical planeof maximum candlepower. 521.5.2.1 CURB LINE SEC-EDG-2MB-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 8,915Initial FC at grade 2MB * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Type II Medium Distribution w/BLS LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 1,610 B0 U0 G1 1,672 B0 U0 G1 04 3,221 B0 U0 G1 3,345 B0 U0 G1 06 4,776 B1 U0 G1 4,959 B1 U0 G1 08 6,368 B1 U0 G1 6,613 B1 U0 G2 10 7,941 B1 U0 G2 8,246 B1 U0 G2 12 9,529 B1 U0 G2 9,895 B1 U0 G2 525mA 02 2,254 B0 U0 G1 2,341 B0 U0 G1 04 4,509 B1 U0 G1 4,682 B1 U0 G1 06 6,686 B1 U0 G2 6,943 B1 U0 G2 08 8,915 B1 U0 G2 9,258 B1 U0 G2 700mA 02 2,754 B0 U0 G1 2,860 B0 U0 G1 04 5,507 B1 U0 G1 5,719 B1 U0 G1 06 8,167 B1 U0 G2 8,481 B1 U0 G2 T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/wall-mount/cree-edge-series-5 Cree Edge™ LED Security Wall Pack Luminaire * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf 2S Type II Short Distribution LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 2,277 B1 U0 G1 2,364 B1 U0 G1 04 4,553 B1 U0 G1 4,728 B1 U0 G1 06 6,752 B2 U0 G2 7,012 B2 U0 G2 08 9,003 B2 U0 G2 9,349 B2 U0 G2 10 11,226 B3 U0 G3 11,658 B3 U0 G3 12 13,472 B3 U0 G3 13,990 B3 U0 G3 525mA 02 3,187 B1 U0 G1 3,310 B1 U0 G1 04 6,375 B2 U0 G2 6,620 B2 U0 G2 06 9,453 B2 U0 G2 9,816 B3 U0 G3 08 12,604 B3 U0 G3 13,088 B3 U0 G3 700mA 02 3,893 B1 U0 G1 4,043 B1 U0 G1 04 7,786 B2 U0 G2 8,086 B2 U0 G2 06 11,546 B3 U0 G3 11,990 B3 U0 G3 ITL Test Report #: 79175SEC-EDG-2S-**-06-E-UL-700-40KInitial Delivered Lumens: 11,704 SEC-EDG-2S-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 12,604Initial FC at grade 1507 4520 6027 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 3014 150˚ 120˚120˚ 60˚ 90˚90˚ 60˚ 30˚ 150˚ 37.5˚ 20'20' 20' 20' 40' 40' 40' 40' 6.1 0m 6.1 12.2 0m 6.16.1 12.212.2 18.318.3 0' 0' 12.2 60'60' Position of vertical planeof maximum candlepower. 521.5.1 CURB LINE .2 20'20' 20' 20' 40' 40' 60' 40' 40' 6.1 0m 6.1 12.2 18.3 0m 6.16.1 12.212.2 18.318.3 0' 0' 12.2 60'60' Position of vertical planeof maximum candlepower. 521.5.1 CURB LINE .2 40˚120˚120˚ 90˚90˚ 60˚60˚ 30˚30º 150˚150˚ 3141 1570 4711 6281 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. CSA Test Report #: 6454ARE-EDG-2SB-**-06-E-UL-700-40KInitial Delivered Lumens: 9,202 SEC-EDG-2SB-**-08-E-UL-525-40K Mounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 9,683Initial FC at grade 2SB * Initial delivered lumens at 25˚C (77˚F) ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Type II Short Distribution w/BLS LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 1,749 B0 U0 G1 1,816 B0 U0 G1 04 3,498 B1 U0 G1 3,633 B1 U0 G1 06 5,188 B1 U0 G1 5,387 B1 U0 G1 08 6,917 B1 U0 G1 7,183 B1 U0 G1 10 8,625 B2 U0 G1 8,957 B2 U0 G1 12 10,350 B2 U0 G2 10,748 B2 U0 G2 525mA 02 2,449 B1 U0 G1 2,543 B1 U0 G1 04 4,898 B1 U0 G1 5,086 B1 U0 G1 06 7,263 B1 U0 G1 7,542 B1 U0 G1 08 9,683 B2 U0 G2 10,056 B2 U0 G2 700mA 02 2,991 B1 U0 G1 3,106 B1 U0 G1 04 5,982 B1 U0 G1 6,212 B1 U0 G1 06 8,871 B2 U0 G1 9,212 B2 U0 G2 T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/wall-mount/cree-edge-series-5 Cree Edge™ LED Security Wall Pack Luminaire * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf 3M Type III Medium Distribution LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 2,027 B1 U0 G1 2,105 B1 U0 G1 04 4,054 B1 U0 G1 4,209 B1 U0 G1 06 6,011 B2 U0 G2 6,242 B2 U0 G2 08 8,015 B2 U0 G2 8,323 B2 U0 G2 10 9,994 B3 U0 G3 10,379 B3 U0 G3 12 11,993 B3 U0 G3 12,454 B3 U0 G3 525mA 02 2,837 B1 U0 G1 2,947 B1 U0 G1 04 5,675 B2 U0 G2 5,893 B2 U0 G2 06 8,415 B2 U0 G2 8,739 B2 U0 G2 08 11,220 B3 U0 G3 11,652 B3 U0 G3 700mA 02 3,466 B1 U0 G1 3,599 B1 U0 G1 04 6,932 B2 U0 G2 7,198 B2 U0 G2 06 10,279 B3 U0 G3 10,674 B3 U0 G3 ITLTest Report #: 79173SEC-EDG-3M-**-06-E-UL-700-40KInitial Delivered Lumens: 10,343 SEC-EDG-3M-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 11,220Initial FC at grade CSA Test Report #: 6448ARE-EDG-3MB-**-06-E-UL-700Initial Delivered Lumens: 7,740 SEC-EDG-3MB-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 8,300Initial FC at grade 1214 3642 4856 120˚120˚ 150˚150˚ 2428 60˚ 90˚90˚ 60˚ 30˚ Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 20'20' 20' 20' 40' 40' 60' 40' 40' 6.1 0m 6.1 12.2 18.3 0m 6.16.1 12.212.2 18.318.3 0' 0' 12.2 60'60' Position of vertical planeof maximum candlepower. 521.5.1 CURB LINE .2 55˚ 120˚120˚ 90˚90˚ 60˚60˚ 30˚ 150˚150˚ 1225 3675 4900 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 2450 20'20' 20' 20' 40' 40' 60' 40' 40' 6.1 0m 6.1 12.2 18.3 0m 6.16.1 12.212.2 18.318.3 0' 0' 12.2 60' Position of vertical planeof maximum candlepower. 521.5.1 CURB LINE .2 60˚ 60' 3MB * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Type III Medium Distribution w/BLS LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 1,499 B1 U0 G1 1,557 B1 U0 G1 04 2,999 B1 U0 G1 3,114 B1 U0 G1 06 4,446 B1 U0 G1 4,617 B1 U0 G1 08 5,929 B1 U0 G2 6,157 B1 U0 G2 10 7,393 B1 U0 G2 7,677 B1 U0 G2 12 8,872 B1 U0 G2 9,213 B1 U0 G2 525mA 02 2,099 B1 U0 G1 2,180 B1 U0 G1 04 4,198 B1 U0 G1 4,359 B1 U0 G1 06 6,225 B1 U0 G2 6,464 B1 U0 G2 08 8,300 B1 U0 G2 8,619 B1 U0 G2 700mA 02 2,564 B1 U0 G1 2,662 B1 U0 G1 04 5,127 B1 U0 G2 5,325 B1 U0 G2 06 7,603 B1 U0 G2 7,896 B1 U0 G2 T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting © 2016 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patent www.cree.com/patents. Cree®, NanoOptic®, and Colorfast DeltaGuard® are registered trademarks, and the Cree logo and Cree Edge™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. The DLC QPL logo is a registered trademarks of Northeast Energy Efficiency Partnerships, Inc. T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Cree Edge™ LED Security Wall Pack Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/wall-mount/cree-edge-series-5 * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf 4M Type IV Medium Distribution LED Count (x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 02 2,138 B1 U0 G1 2,220 B1 U0 G1 04 4,276 B1 U0 G1 4,440 B1 U0 G1 06 6,340 B2 U0 G2 6,584 B2 U0 G2 08 8,454 B2 U0 G2 8,779 B2 U0 G2 10 10,542 B2 U0 G2 10,947 B3 U0 G3 12 12,650 B3 U0 G3 13,137 B3 U0 G3 525mA 02 2,993 B1 U0 G1 3,108 B1 U0 G1 04 5,986 B2 U0 G2 6,216 B2 U0 G2 06 8,876 B2 U0 G2 9,218 B2 U0 G2 08 11,835 B3 U0 G3 12,290 B3 U0 G3 700mA 02 3,656 B1 U0 G1 3,796 B1 U0 G1 04 7,311 B2 U0 G2 7,593 B2 U0 G2 06 10,842 B3 U0 G3 11,259 B3 U0 G3 SEC-EDG-4M-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G.Initial Delivered Lumens: 11,835Initial FC at grade ITL Test Report #: 78793SEC-EDG-4M-**-06-E-UL-700-40KInitial Delivered Lumens: 11,607 120˚120˚ 90˚90˚ 60˚60˚ 30˚ 150˚150˚ 1828 5483 7311 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 3656 20' 20' 20'20' 40' 40'40' 6.1 0m 6.1 12.2 12.218.3 6.10m 6.1 12.2 18.324.4 24.4 24.4 0' 0' 40'12.2 18.3 18.360' 60'60'80'80'80' 60' Position of vertical planeof maximum candlepower. CURB LINE 40˚ 2 1.5.2.1 5 SEC-EDG-4MB-**-08-E-UL-525-40KMounting Height: 10' (3.0m) A.F.G. Initial Delivered Lumens: 8,915Initial FC at grade CSA Test Report #: 6449 ARE-EDG-4MB-**-12-E-UL-525-40K Initial Delivered Lumens: 13,155 120˚120˚ 90˚ 60˚60˚ 30˚30º 150˚150˚ 5267 2633 7900 10534 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 90˚ 20' 20' 20'20' 40' 40'40' 6.1 0m 6.1 12.2 12.218.3 6.10m 6.1 12.2 18.324.4 24.4 24.4 0' 0' 40'12.2 18.3 18.360' 60'60'80'80'80' 60' Position of vertical planeof maximum candlepower. CURB LINE 40˚ 2 1.5.2.1 5 4MB * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Type IV Medium Distribution w/BLS LED Count (x10) 4000K 5700K Initial DeliveredLumens* BUG Ratings** Per TM-15-11 Initial DeliveredLumens* BUG Ratings** Per TM-15-11 350mA 02 1,610 B0 U0 G1 1,672 B0 U0 G1 04 3,221 B1 U0 G1 3,345 B1 U0 G1 06 4,776 B1 U0 G1 4,959 B1 U0 G1 08 6,368 B1 U0 G2 6,613 B1 U0 G2 10 7,941 B1 U0 G2 8,246 B1 U0 G2 12 9,529 B1 U0 G2 9,895 B1 U0 G2 525mA 02 2,254 B0 U0 G1 2,341 B0 U0 G1 04 4,509 B1 U0 G1 4,682 B1 U0 G1 06 6,686 B1 U0 G2 6,943 B1 U0 G2 08 8,915 B1 U0 G2 9,258 B1 U0 G2 700mA 02 2,754 B0 U0 G1 2,860 B0 U0 G1 04 5,507 B1 U0 G1 5,719 B1 U0 G2 06 8,167 B1 U0 G2 8,481 B1 U0 G2 Introduction The WST LED is designed with the specifier in mind. The traditional, trapezoidal shape offers a soft, non-pixilated light source for end-user visual comfort. For emergency egress lighting, the WST LED offers six battery options, including remote. For additional code compliance and energy savings, there is also a Bi-level motion sensor option. With so many standard and optional features, three lumen packages, and high LPW, the WST LED is your “go to” luminaire for most any application. NOTES 1 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). Specify 120, 208, 240 or 277 options only. when ordering with button type photocell (PE), fusing (SF, DF), or dual switching (DS). 2 Also available as a separate accessory; see accessories information. 3 Top conduit entry standard. 4 Not available with PE, PER, PER5, PER7, VG or WG. 5 Not available with MVOLT option. Button photocell (PE) can be ordered with a dedicated voltage option. Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. 6 Not available with E7WH, E7WC, E7WHR, E20WC, E20WH, or E23WHR. Used with inverter system. Not available with 347/480V. Not available with PE, PER, PER5 & PER7. 7 Not available with 347/480V. 8 Battery pack rated for -20° to 40°C. 9 Comes with PBBW. 10 Warranty period is 3-years. 11 Not available with BBW. 12 Must order with fixture; not an accessory. WST LED Series Performance Package Color temperature Distribution Voltage Mounting WST LED P1 1,500 Lumen package P2 3,000 Lumen package P3 6,000 Lumen package 27K 2700 K 30K 3000 K 40K 4000 K 50K 5000 K VF Visual comfort forward throw VW Visual comfort wide MVOLT1 1201 2081 2401 2771 347 480 Shipped included (blank)Surface mounting bracket Shipped separately BBW Surface-mounted back box2 PBBW Premium surface-mounted back box2,3 Options Finish (required) PE Photoelectric cell, button type PER NEMA twist-lock receptacle only PER5 Five-wire receptacle only PER7 Seven-wire receptacle only PIR Motion/Ambient Light Sensor, 8-15' mounting height4 PIR1FC3V Motion/ambient sensor, 8-15' mounting height, ambient sensor enabled at 1fc4 PIRH 180° motion/ambient light sensor, 15-30' mounting height4 PIRH1FC3V Motion/ambient sensor, 15-30' mounting height, ambient sensor enabled at 1fc4 SF Single fuse (120, 277, 347V)5 DF Double fuse (208, 240, 480V)5 DS Dual switching6 E7WH Emergency battery backup (7W)7 E7WC Emergency battery backup (cold, 7W)7,8 E7WHR Remote emergency battery backup (remote 7W)7,9 E20WH Emergency battery backup (20W)7,10 E20WC Emergency battery backup (cold, 20W)7,8,10 E23WHR Remote emergency battery backup (remote 20W)7,9 LCE Left side conduit entry11 RCE Right side conduit entry11 Shipped separately RBPW Retrofit back plate2 VG Vandal guard12 WG Wire guard12 DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DSSXD Sandstone DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white DSSTXD Textured sandstone Accessories Ordered and shipped separately. WSTVCPBBW DDBXD U Premium Surface - mounted back box WSBBW DDBTX U Surface - mounted back box RBPW DDBXD U Retrofit back plate WST LED Architectural Wall Sconce Luminaire Ordering Information EXAMPLE: WST LED P1 40K VF MVOLT DDBTXD Catalog Number Notes Type Height:8-1/2” (21.59 cm) Width:17” (43.18 cm) Depth:10-3/16” (25.9 cm) Weight: 20 lbs(9.1 kg) One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. Hit the Tab key or mouse over the page to see all interactive elements. Optional Back Box (BBW) Height:4” (10.2 cm) Width:5-1/2” (14.0 cm) Depth:1-1/2” (3.8 cm) Specifications WST-LED Rev. 03/30/17 4.45 3.0 DFOR 3/4" NPTSIDE-ENTRY H W FOR 1/4"MOUNTINGBOLTS H The emergency battery backup is integral to the luminaire — no external housing required! This design provides reliable emergency operation while maintaining the aesthetics of the product. All emergency backup configurations include an independent secondary driver with an integral relay to immediately detect AC power loss, meeting interpretations of NFPA 70/NEC 2008 - 700.16 The emergency battery will power the luminaire for a minimum duration of 90 minutes (maximum duration of three hours) from the time supply power is lost, per International Building Code Section 1006 and NFPA 101 Life Safety Code Section 7.9, provided luminaires are mounted at an appropriate height and illuminate an open space with no major obstructions. The examples below show illuminance of 1 fc average and 0.1 fc minimum of the P1 power package and VF distribution product in emergency mode. 10' x 10' Gridlines 8' and 12' Mounting Height Emergency Battery Operation 8' MH 12' MH Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Performance Package System Watts (MVOLT1) Dist. Type 27K (2700K, 70 CRI) 30K (3000K, 70 CRI) 40K (4000K, 70 CRI) 50K (5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P1 12W VF 1,494 0 0 0 125 1,529 0 0 0 127 1,639 0 0 0 137 1,639 0 0 0 137 VW 1,513 0 0 0 126 1,548 0 0 0 129 1,660 0 0 0 138 1,660 0 0 0 138 P2 25W VF 3,162 1 0 1 126 3,236 1 0 1 129 3,468 1 0 1 139 3,468 1 0 1 139 VW 3,202 1 0 0 128 3,277 1 0 0 131 3,512 1 0 0 140 3,512 1 0 0 140 P3 50W VF 6,023 1 0 1 120 6,164 1 0 1 123 6,607 1 0 1 132 6,607 1 0 1 132 VW 6,100 1 0 1 122 6,242 1 0 1 125 6,691 1 0 1 134 6,691 1 0 1 134 Performance Data One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. Lumen Output Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers Ambient Lumen Multiplier 0°C 32°F 1.03 10°C 50°F 1.02 20°C 68°F 1.01 25°C 77°F 1.00 30°C 86°F 0.99 40°C 104°F 0.98 Projected LED Lumen Maintenance Values calculated according to IESNA TM-21-11 methodology and valid up to 40°C. Operating Hours 0 25,000 50,000 100,000 Lumen Maintenance Factor 1.0 >0.95 >0.92 >0.87 WST-LED Rev. 03/30/17 Current (A) Performance package System Watts 120 208 240 277 347 480 P1 11 0.1 0.06 0.05 0.04 ------ 14 ------------0.04 0.03 P1 DS 14 0.12 0.07 0.06 0.06 ------ P2 25 0.21 0.13 0.11 0.1 ------ 30 ------------0.09 0.06 P2 DS 25 0.21 0.13 0.11 0.1 ------ P3 50 0.42 0.24 0.21 0.19 ------ 56 ------------0.16 0.12 P3 DS 52 0.43 0.26 0.23 0.21 ------ Electrical Load WST LED P1 27K VF MVOLT E7WH WST LED P2 40K VF MVOLT E20WH 8' MH 12' MH To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s WST LED homepage. 0 0 11 22 33 44 -1 -2 -3 -4 1 2 3 40 0 11 22 33 44 -1 -2 -3 -4 1 2 3 4 Photometric Diagrams FEATURES & SPECIFICATIONS INTENDED USE The classic architectural shape of the WST LED was designed for applications such as hospitals, schools, malls, restaurants, and commercial buildings. The long life LEDs and driver make this luminaire nearly maintenance-free. CONSTRUCTION The single-piece die-cast aluminum housing integrates secondary heat sinks to optimize thermal transfer from the internal light engine heat sinks and promote long life. The driver is mounted in direct contact with the casting for a low operating temperature and long life. The die-cast door frame is fully gasketed with a one-piece solid silicone gasket to keep out moisture and dust, providing an IP65 rating for the luminaire. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural aluminum, sandstone and white. Available in textured and non-textured finishes. OPTICS Well crafted reflector optics allow the light engine to be recessed within the luminaire, providing visual comfort, superior distribution, uniformity, and spacing in wall-mount applications. The WST LED has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine(s) consist of 98 high-efficacy LEDs mounted to a metal core circuit board and integral aluminum heat sinks to maximize heat dissipation and promote long life (100,000 hrs at 40°C, L87). Class 2 electronic driver has a power factor >90%, THD <20%. Easily-serviceable surge protection device meets a minimum Category B (per ANSI/IEEE C62.41.2). INSTALLATION A universal mounting plate with integral mounting support arms allows the fixture to hinge down for easy access while making wiring connections. LISTINGS CSA certified to U.S. and Canadian standards. Luminaire is IP65 rated. PIR back box options are rated for wet location. Rated for -30°C to 40°C ambient. DesignLights Consortium® (DLC) Premium qualified product. Not all versions of this product may be DLC Premium qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx. Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. Isofootcandle plots for the WST LED P3 40K VF and VW. Distances are in units of mounting height (10’). LEGEND 0.1 fc 0.5 fc 1.0 fc 5.0 fc Test No. 30965P32 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 VF Test No. 31115P32 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 VW Distribution overlay comparison to 175W metal halide. LEGEND WST LED, 0.5 fc WST HID, 0.5 fc 10’ W Sidewalk LLDs: WST HID = 0.72 WST LED = 0.95 WST LED P3 40K VF,WST 175M FT Probe, 12’ Mounting Ht WST HID: 213W WST LED: 50W WST-LED Rev. 03/30/17 T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting Rev. Date: V2 07/27/2016 Ordering Information Example: PKG-304-5M-DM-04-E-UL-SV-700 304 Series™ LED Parking Structure Luminaire PKG-304 E Product Optic Mounting LED Count (x10)Series Voltage Color Options Drive Current Options PKG-304 5MType V Medium 5S Type V Short PSPetroleum Symmetric SLSparklePetroleum 40 40˚ Flood DMDirect HC Hook & Cord PDPendant 04 06 E ULUniversal120-277V UHUniversal347-480V BKBlack BZ Bronze SVSilver WH White 350350mA 525 525mA 700700mA DIM 0-10V Dimming -Control by others -Refer to Dimming spec sheet for details -Can't exceed of specified drive current F Fuse -Available with UL voltage only -When code dictates fusing use time delay fuse -Refer to ML spec sheet for availability with ML options J Alternate Junction Box Mounting -For direct mount only -Alternate bracket to fit 4" (102mm) square and RACO279 J-Box ML Multi-Level -Refer to ML spec sheet for details -Intended for downlight applications at 0˚ tilt PML Programmable Multi-Level -Refer to PML spec sheet for details -Intended for downlight applications at 0˚ tilt 40K 4000K Color Temperature -Minimum 70 CRI -Color temperature per luminaire Product Description Slim, low profile design. Luminaire is constructed from rugged die cast and extruded aluminum components. LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire. High performance aluminum heat sinks specifically designed for LED parking structure application. Applications: Parking structures and low-medium bay general lighting Accessories Field-Installed Bird Guard- For pendant or hook & cord mount onlyXA-XCPBRDGRD For Pendant Mount Luminaires Leveler- For 0-13˚ Sloped CeilingsXA-PNDTLVL** FittingXA-PSFTG** Pendant Mount Kits- Includes conduit fitting and threaded pipe- Pendant height from ceiling surface to bottom of the luminaire; mounting accessories or surface boxes will add to overall height XA-PS12KIT** – 12" (305mm) XA-PS18KIT** – 18" (457mm) XA-PS22KIT** – 22" (559mm) For Hook & Cord Mount Luminaires Locking Type Plug XA-L515P – 120VXA-L615P – 208/240VXA-L715P – 277VXA-L3720P – 347V Locking Type Receptacle XA-L515R – 120VXA-L615R – 208/240VXA-L715R – 277VXA-L720R – 347V Steady Lock- For eyeboltSL-C Hand-Held RemoteXA-SENSREM- For successful implementation of the programmable multi-level option, a minimum of one hand-held remote is required Patented NanoOptic® Product Technology Made in the U.S.A. of U.S. and imported parts CRI: Minimum 70 CRI CCT : 4000K (+/- 300K), 5700K (+/- 500K) Standard Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish Performance Summary DM Mount 12.0" SQ(305mm) 7.0"(178mm)7.5"(189mm) † See http://lighting.cree.com/warranty for warranty terms ** Must specify color LED Count (x10)Weight 04 20.4 lbs. (9.3kg) 06 20.8 lbs. (9.4kg) T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting Product Specifications CONSTRUCTION & MATERIALS • Slim, low profile design • Constructed from rugged die cast and extruded aluminum components • LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire • High performance heat sinks specifically designed for LED parking structure application • Direct mounting bracket is designed to mount directly over existing single gang and octagonal junction boxes for direct mount • Hook and cord mount provided with spring lock hook for mounting and 1.5' (0.5m) of cord • Pendant mount includes 36" (419mm) cord out of the luminaire and is intended to be mounted by 3/4 IP pendant (by others) • Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze, silver, and white are available • Weight: See Weight Charts on pages 1 and 5 ELECTRICAL SYSTEM • Input Voltage: 120-277V or 347-480V, 50/60Hz, Class 1 drivers • Power Factor: > 0.9 at full load • Total Harmonic Distortion: < 20% at full load • Integral 10kV surge suppression protection standard • To address inrush current, slow blow fuse or type C/D breaker should be used • 10V Source Current: 0.15mA REGULATORY & VOLUNTARY QUALIFICATIONS • cULus Listed • Suitable for wet locations • Enclosure rated IP66 per IEC 60529 • Consult factory for CE Certified products • 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 • Meets FCC Part 15 standards for conducted and radiated emissions • DLC qualified when ordered with 5M or 5S optics. Please refer to www.designlights.org/QPL for most current information • Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 • RoHS Compliant. Consult factory for additional details • Meets Buy American requirements within ARRA 1 Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ luminaire testing2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) 304 Series™ LED Parking Structure Luminaire Recommended 304 Series™ Lumen Maintenance Factors (LMF)1 Ambient InitialLMF 25K hrProjected2 LMF 50K hrProjected2 LMF 75K hrCalculated3 LMF 100K hrCalculated3 LMF 5˚C (41˚F)1.04 0.99 0.97 0.95 0.93 10˚C (50˚F)1.03 0.98 0.96 0.94 0.92 15˚C (59˚F)1.02 0.97 0.95 0.93 0.91 20˚C (68˚F)1.01 0.96 0.94 0.92 0.90 25˚C (77˚F)1.00 0.95 0.93 0.91 0.89 Electrical Data* LED Count(x10) System Watts120-480V Total Current 120V 208V 240V 277V 347V 480V 350mA 04 46 0.39 0.24 0.22 0.21 0.15 0.12 06 69 0.57 0.34 0.30 0.27 0.21 0.16 525mA 04 71 0.59 0.35 0.31 0.28 0.21 0.16 06 101 0.84 0.49 0.43 0.38 0.30 0.22 700mA 04 94 0.79 0.46 0.40 0.36 0.28 0.21 06 135 1.14 0.65 0.57 0.50 0.40 0.29 * Electrical data at 25˚C (77˚F) T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/parking-structure/304-series-2 304 Series™ LED Parking Structure Luminaire T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada 5M ITL Test Report #: 77285PKG-304-5M-**-06-E-UL-700-40KInitial Delivered Lumens: 11,681 120˚120˚ 90˚90˚ 60˚60˚ 30˚30º 150˚150˚ 973 2919 3892 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 1946 PKG-304-5M-**-06-E-UL-700-40KMounting Height: 15' (4.6m) A.F.G.Initial Delivered Lumens: 11,625Initial FC at grade Position of vertical planeof maximum candlepower. 0˚ CURB LINE 0m6.118.312.2 18.3 18.3 0m0' 6.120' 6.120' 60' 24.480' 24.480' 12.240' 12.240' 60' 40' 18.3 60'20' 12.2 40' 6.1 20'0'60' 24.4 80' 24.4 80' .5.2 .1 2 1 * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Type V Medium Distribution LED Count(x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 04 4,595 B3 U1 G1 4,771 B3 U1 G1 06 6,838 B3 U1 G1 7,101 B3 U1 G2 525mA 04 6,433 B3 U1 G1 6,680 B3 U1 G1 06 9,574 B3 U1 G2 9,942 B3 U1 G2 700mA 04 7,811 B3 U1 G2 8,111 B3 U1 G2 06 11,625 B4 U1 G2 12,072 B4 U1 G2 5S ITL Test Report #: 77876PKG-304-5S-**-06-E-UL-700-40KInitial Delivered Lumens: 12,738 120˚120˚ 90˚90˚ 60˚60˚ 30˚30º 150˚150˚ 1235 3706 4941 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 2471 PKG-304-5S-**-06-E-UL-700-40KMounting Height: 15' (4.6m) A.F.G.Initial Delivered Lumens: 12,917Initial FC at grade Position of vertical planeof maximum candlepower. 45˚ 0m6.118.312.2 18.3 18.3 24.4 24.4 24.424.4 0m0' 6.120' 6.120' 60' 12.240' 12.240' 60' 40' 18.3 60'80' 80' 80' 80'20' 12.2 40' 6.1 20'0'60' CURB LINE * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Type V Short Distribution LED Count(x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 04 5,105 B2 U0 G1 5,302 B2 U0 G1 06 7,598 B3 U0 G1 7,890 B3 U0 G1 525mA 04 7,147 B3 U0 G1 7,422 B3 U0 G1 06 10,637 B3 U0 G2 11,046 B3 U0 G2 700mA 04 8,679 B3 U0 G1 9,013 B3 U0 G1 06 12,917 B3 U0 G2 13,413 B3 U0 G2 T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting SL ITL Test Report #: 77415CAN-304-SL-**-06-E-UL-700-40KInitial Delivered Lumens: 12,707 120˚120˚ 90˚90˚ 60˚60˚ 30˚30˚ 150˚150˚ 1111 3333 4444 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 2222 PKG-304-SL-**-06-E-UL-700-40KMounting Height: 15' (4.6m) A.F.G.Initial Delivered Lumens: 12,773Initial FC at grade 45˚ CURB LINE 0m6.1 18.312.2 18.3 18.3 0m0' 6.120' 6.120' 60' 12.240' 12.240' 60' 40' 18.3 60'20' 12.2 40' 6.1 20'0'60' 2 Position of vertical planeof maximum candlepower. 1 .5 .2 .1 * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf Sparkle Petroleum Distribution LED Count(x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 04 5,048 B2 U0 G1 5,243 B2 U0 G1 06 7,514 B3 U0 G1 7,803 B3 U0 G1 525mA 04 7,068 B2 U0 G1 7,340 B2 U0 G1 06 10,519 B3 U0 G1 10,924 B3 U0 G1 700mA 04 8,582 B3 U0 G1 8,912 B3 U0 G1 06 12,773 B3 U0 G1 13,264 B3 U0 G1 * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/parking-structure/304-series-2 304 Series™ LED Parking Structure Luminaire PS ITL Test Report #: 76940CAN-304-PS-**-06-E-UL-700-40KInitial Delivered Lumens: 13,581 120˚120˚ 90˚90˚ 60˚60˚ 30˚30˚ 150˚150˚ 1357 4070 5426 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 2713 PKG-304-PS-**-06-E-UL-700-40KMounting Height: 15' (4.6m) A.F.G.Initial Delivered Lumens: 13,204Initial FC at grade 45˚ CURB LINE 0m6.1 18.312.2 18.3 18.3 0m0' 6.120' 6.120' 60' 12.240' 12.240' 60' 40' 18.3 60'20' 12.2 40' 6.1 20'0'60' 2 Position of vertical planeof maximum candlepower. 1.5 .2.1 Petroleum Symmetric Distribution LED Count(x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 04 5,219 B2 U0 G0 5,419 B2 U0 G0 06 7,767 B3 U0 G0 8,066 B3 U0 G0 525mA 04 7,306 B3 U0 G0 7,587 B3 U0 G0 06 10,874 B3 U0 G0 11,292 B3 U0 G0 700mA 04 8,872 B3 U0 G0 9,213 B3 U0 G0 06 13,204 B3 U0 G0 13,712 B3 U0 G0 T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting © 2016 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patent www.cree.com/patents. Cree®, NanoOptic®, and Colorfast DeltaGuard® are registered trademarks, and the Cree logo and 304 Series™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. The DLC QPL logo is a registered trademark of Northeast Energy Efficiency Partnerships, Inc. Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/products/outdoor/parking-structure/304-series-2 304 Series™ LED Parking Structure Luminaire PD Mount 7.2"(183mm) 7.8"(196mm) 12.0" SQ(305mm) HC Mount 8.8"(223mm) 9.4"(239mm) 10.0"(253mm) 12.0" SQ(305mm) LED Count (x10)Weight 04 18.1 lbs. (8.2kg) 06 18.6 lbs. (8.4kg) LED Count (x10)Weight 04 18.5 lbs. (8.4kg) 06 18.8 lbs. (8.5kg) T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada 40˚ ITL Test Report #: 78011CAN-304-40-**-06-E-UL-700-40KInitial Delivered Lumens: 12,497 4150 8299 12449 16598 Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower. 120˚120˚ 90˚90˚ 60˚60˚ 30˚ 150˚150˚ PKG-304-40-**-06-E-UL-700-40KMounting Height: 15' (4.6m) A.F.G.Initial Delivered Lumens: 12,917Initial FC at grade 20' 20' 20'20' 0' 0' 0m6.13.012.212.2 40' 2 40' 40'40'60'60'60' 60' 0m 6.1 6.1 12.2 12.2 18.3 18.318.3 18.3 1.5 .2 .1 * Initial delivered lumens at 25˚C (77˚F)** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf 40˚ Flood Distribution LED Count(x10) 4000K 5700K InitialDeliveredLumens* BUGRatings** Per TM-15-11 InitialDeliveredLumens* BUGRatings** Per TM-15-11 350mA 04 5,105 N/A 5,302 N/A 06 7,598 N/A 7,890 N/A 525mA 04 7,147 N/A 7,422 N/A 06 10,637 N/A 11,046 N/A 700mA 04 8,679 N/A 9,013 N/A 06 12,917 N/A 13,413 N/A GS - R64 1/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS Client Project name Order# Type Qty FEATURES AND BENEFITS Physical :• Low copper content extruded aluminum housing• Available in 1', 2', 3' or 4' sections•  Electro-statically applied polyester powder coat finish• Machined aluminum end caps and silicone gaskets• Stainless steel hardware• Clear tempered glass lens• Asymmetric wallwash, 8° x 8°, 10° x 10°, 10° x 30°, 10° x 60°, 10° x 90°, 15° x 25°, 30° x 30°, 30° x 60°, 35° x 35°, 50° x 80°, 60° x 60°, 80° x 80°, or 90° x 90° optics• IP66• IK07 rated (asymmetric wallwash lens is IK06 rated) • Meets 3G ANSI C136.31 Vibration standard for bridge applications• Corrosion-resistant coating for hostile environments2 Performance :• 2200K, 2700K, 3000K, 3500K, 4000K, Red, Green, Blue static colors available• CRI value: 80+• Minimum 1fc (10.7 lux) @ 140ft (43m) distance (HO 4000K, 4' unit, 10° x 60° optic)• Lumen maintenance: 120,000 hrs [L70 @ 25°C]• Lumen measurements comply with LM - 79 - 08 standard•  Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM)• Operating temperatures: -25° C to 50° C [-13F to 122F] Electrical :• Line voltage luminaire for 100 to 277V• Power and data in 1 cable (#16-5)• End-to-end option (ETE): 16" black input cable, no jumper cable needed•  252ft [77m] maximum cable and fixture run length, non-dimming, 277V, RO version•  164ft [50m] maximum cable and fixture run length, non-dimming, 277V, HO version•  5W/ft version meets ASHRAE standards for linear lighting on building facades3 •  8.5W/ft Regular Output version3 •  15.25W/ft High Output version3 •  Dimming options: Lumentalk, 0-10 volt, DALI, Lutron® EcoSystem® or DMX/RDM enabled 1 Asymmetric wallwash lens is IK06 rated. 2 Use only when exposed to salt spray and harsh chemicals. This option is not required for normal outdoor exposure! 3  ASHRAE version not available for 1' fixture lengths. Power consumption is typically 20% higher for 1' fixture lengths. DeliveredOutput [lm] 10ºx10º 10ºx30º 30ºx60º 60ºx60º 4ft HO, 4000K Intensity[peak cd] 3,768*38,346* 8ºx8º4,045 77,896 3,830 30,056 10ºx60º3,692 19,654 3,862*5,119* 3,447*3,015* 90ºx90º3,592 1,886 WW 3,592 5,159 10ºx90º3,576 7,897 30ºx30º3,765 14,726 Photometric Summary Photometric performance is measured incompliance with IESNA LM-79-08.*Estimated. Consult Lumenpulse websitefor the latest IES and LDT files. 4" [102mm] Minimumspacing 2 516" 41 ,37 3 8"25 3 8", 49 3 8" [645mm, 949mm , 1254mm] [59mm] 312 " [89mm] " [7mm] 2" [51mm] 16" Input cable [406mm] 13 3 8" [340mm] SIDE VIEW FRONT VIEW 1ft fixture, ETE option shown 2ft, 3ft and 4ft fixtures, ETE option shown TOP VIEW IK071 GS - R64 2/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS Always position frosted side toward the wall WWLF Asymmetric Wallwash Optic, Left Feed RIGHT SIDE VIEW(Fixture pointing upwards)FRONT VIEW TOP VIEW *Fixture’s feeding side is based on uplight installations. Feedingsides are reversed when fixture isused in a downlight application. Recommended setback from wall is 1/10 of the wall height. Example: 2ft [0.6m] setback for a20ft [6m] wall. INPUT Wall side WWRF Asymmetric Wallwash Optic, Right Feed INPUT Wall side ASYMMETRIC WALLWASH OPTIC FEEDING SIDE DETAIL GS - R64 3/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS MOUNTING OPTIONS WAMMounting Hole Pattern 2X 1/4”THRU ALL 2 1/2” 1 3/4” 3/8” [64mm] [45mm] [10mm]1 1/16”[27mm] WAM2 Adjustable Wall Mounting 2" WAM6 Adjustable Extended Arm Mounting 6" WAM12Adjustable Extended Arm Mounting 12" WAM18 Adjustable Extended Arm Mounting 18" Surface Mount Wall Mount UMASUniversal Adjustable Mounting 0 [340mm] 13 3 8 " [492mm] 19 3 8 " [187mm] 7 3 8 " [35mm] 13 8 " [108mm] 4 1 4 " UMP Mounting Hole Pattern 2X 9/32”THRU ALL 3 1/2” 2 7/8” [89mm] [73mm] 3/4”[19mm]3/8” [10mm] 3/16”[5mm] UMASMounting Hole Pattern 2 1/2” 1 3/4” 3/4” 3/8”3/8” 2X 9/32”THRU ALL [64mm] [45mm] [19mm] [10mm] [10mm] [3mm] 18 " UMP Fixed Mounting SAM Slim Adjustable Mounting [10mm] 38 " 0° 180° 90° 0° 60° -60° 0° 115° -115° 0° 115° -115° 0° 115° -115° 8 " [4mm] R 1 38 "[10mm] 134 "[83mm] SAMMounting Hole Pattern 2 [71mm] 1316 " GS - R64 4/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS LOUVER ACCESSORY INSTALLATION DETAIL Not suitable for asymmetric wallwash optic ETE -End-to-end configuration,16" black input cable,no jumper cable needed. ETE Input CableETE Leader Cable(order separately) OPTION 8"2 [60mm] 3 13 7 16 7 16 7 16", 25 ", 37 7 16 ", 49 [341mm, 646mm, 951mm,1256mm] " [60mm]8 "2 3 4"[102mm] LOGRD Radial Louver for Lumenfacade (See page 6 for ordering code) [24mm] [11mm]16"7 Blade depth 1" [25mm] Blade spacing FRONT VIEW SIDE VIEW TOP VIEW 16"15 GS - R64 5/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS ACCESSORIES Order separately Control Systems: LTO2 Lumentouch is a wall mount DMX 512 controller keypad. LCU Lumencue is a USB / mini SD DMX 512 controller. LID LumenID is a diagnostic and addressing DMX 512 controller. It must be specifi ed for all DMX applications. Refer to LID specifi cation sheet for details. LID-LT LumentalkID is a diagnostic and addressing controller. It must be specifi ed for all Lumentalk (LT) applications. Refer to LID-LT specifi cation sheet for details. LTN Lumentone is a simple pre-programmed DMX 512 controller with a push button rotary dial and live feedback. Control Boxes: CBX LDB DMX/RDM control box. Up to six power and data outputs to fi xtures or fi xture runs. Ethernet enabled option. Refer to CBX specifi cation sheet for details. Lumentalk Data Bridge, 0-10V or DMX output. Refer to LDB specifi cation sheet for details. GS - R64 6/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS ACCESSORIES - continued Order separately Radial Louver : Not suitable for asymmetric wallwash optic LOGRD___-___Radial louver for Lumenfacade. Louver blade depth: 7/16" [11mm]; louver blade spacing: 1" [25mm] Please specify nominal length (1', 2', 3' or 4' [0.3m, 0.6m, 0.9m or 1.2m]) and finish (BK-Black Sandtex,  BRZ-Bronze Sandtex, SI-Silver Sandtex, or WH-Smooth white. Custom color available on request, please specify as CC together with RAL color : _________). The addition of a louver will affect beam distribution, consult factory for application support. Leader and Jumpers Cables for Standard Construction : LOGLC-__-STD-__-__Leader Cable for Lumenfacade.Please specify certification (UL or CE), cable length (10', 25', 50',100', 150' or 200' [3m, 7.6m,15.2m, 30m, 45m or 61m] standard) and cable color (BK-Black or WH-White, connectors are black as standard).Suitable for dimming/data and non-dimming applications.Sealing endcap is mandatory for any unused connector. (1) included with every leader cable.Consult Lumenfacade leader cable specifiation sheet for details. LOGJC-__-STD-__-__Jumper Cable for Lumenfacade. Please specify certification (UL or CE), cable length (1', 2', 3', 4', 5' or 50' [0.3m, 0.6m, 0.9m, 1.2m, 1.5m or 15m] standard) and cable color (BK-Black or WH-White, connectors are black as standard). Lengths between 5' and 30' [1.5m and 10m] are also available, please specify desired length in 1' [0.3m] increments. Suitable for dimming/data and non-dimming applications. Consult Lumenfacade jumper cable specifiation sheet for details. Leader and Jumpers Cables for End-to-End (ETE) Option : LOGLC-__-ETE__-__Leader Cable for Lumenfacade, ETE option. Please specify certification (UL or CE), cable length (10', 25', 50',100', 150' or 200' [3m, 7.6m,15.2m,  30m, 45m or 61m] standard) and cable color (BK-Black or WH-White, connectors and fixture input cables  are black as standard). Suitable for dimming/data and non-dimming applications. Sealing endcap is mandatory for any unused connector. (1) included with every leader cable. Consult Lumenfacade leader cable specifiation sheet for details. LOGJC-__-ETE-__-__Jumper Cable for Lumenfacade, ETE option. Please specify certification (UL or CE), cable length (1', 2', 3', 4', 5' or 50' [0.3m, 0.6m, 0.9m, 1.2m, 1.5m or 15m] standard) and cable color (BK-Black or WH-White, connectors and fixture input cables are  black as standard). Lengths between 5' and 30' [1.5m and 10m] are also available, please specify desired length in 1' [0.3m] increments. Suitable for dimming/data and non-dimming applications. Consult Lumenfacade jumper cable specifiation sheet for details. GS - R64 7/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS RESOLUTION DETAILS Applicable for DMX/RDM control option only. Fixture resolution can be configured on-site within the LumenID V3 software. A DMX/RDM enabled CBX is required. Resolution per fixture: each fixture is addressed independently Resolution per foot: each foot is addressed independently DMX ADDRESSES: DMX ADDRESSES: LOG 48 inches LOG 48 inches 1 2 LOG 48 inchesTOP VIEW TOP VIEW LOG 48 inches 1 2 3 4 5 6 7 8 GS - R64 8/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORSTYPICAL WIRING DIAGRAMS Wiring Color Code AmericanColor Code CEColor Code Black Brown Red/Purple BlackOrangeGrey White Blue USE Live 100-277V 0-10V / Data + Green Yellow/Green Ground 0-10V / Data - Neutral A - Power input (100-277V)B - Junction box (by others)C - Leader cable (LOGLC)D - Lumenfacade (LOG-NO) E - Jumper cable (LOGJC)F - Sealing end cap Non-Dimming (NO) Non-Dimming (NO) - Wiring detail A - Power inputB - To fixtureC - LineD - GroundE - NeutralF - Wire-nuts (by others)G - Junction box (by others) A B CDE FG A B C D FE Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations.• ASHRAE version: 5 watts per foot [0.3m], Regular Output version: 8.5 watts per foot [0.3m], High Output version: 15.25 watts per foot [0.3m]. GS - R64 9/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS Wiring Color Code AmericanColor Code CEColor Code Black Brown Red/Purple BlackOrangeGrey White Blue USE Live 100-277V 0-10V / Data + Green Yellow/Green Ground 0-10V / Data - Neutral A - Power input (control over power line via Lumentalk system)B - GroundC - LineD - NeutralE - 0-10V + / Data +F - 0-10V - / Data -G - To fixture Wiring detail using LDB-DIM or LDB-DMX (for 1' fixtures [0.3 m]) Lumentalk (LT) 1% minimum dimming value Lumentalk (LT) - Wiring detail (for 2, 3 or 4' fixture lengths [0.6, 0.9 or 1.2m] G A DCB FE G B J K HFEDC A I Lumentalk 1% minimum dimming value G A - Third party dimmer/controllerB - Lumentranslator (LTL-010,DMX, -TRIAC, -DALI)C - Data wiring (by others)D - Power line (120-277V AC)E - Junction box (by others)F - Lumentalk Data Bridge (LDB-DIM or LDB-DMX)G - Leader cable (LOGLC)H - Lumenfacade 1' [0.3m] (LOG-DIM or LOG -DMX/RDM)I - Jumper cable (LOGJC)J - Lumenfacade (LOG-LT)     (2', 3', or 4' fixture lengths) [0.6, 0.9 or 1.2m]K - Sealing end cap Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations.• Lumentalk Data Bridge required for 1' [0.3m] fixture lengths.   For applications with all fixtures controlled as 1 zone: fixtures and Lumentalk Data Bridge must be specified as DIM. Maximum of 10 fixtures per LDB-DIM, consult factory for applications that require additional   capabilities.For application with fixtures controlled individually: fixtures and Lumentalk Data Bridge must be specified as DMX, 2-step commissioning process: 1 - DMX/RDM system using LumenID software and a  LID, 2 - Lumentalk system using LumentalkID software and a LID-LT. Maximum of 32 fixtures per LDB-DMX. Consult factory for details.• For DMX applications: 1 DMX controller per Lumentalk network, maximum of 48 DMX channels per Lumentalk network (minimum step transition update rate is 1 second, minimum fade time between two colors is 1 minute). Consult factory for applications that require additional capabilities.• Maximum of 1 transmitter (Lumentranslator or Lumenlink) per system• No third party fixtures allowed on the same circuit. • Consult factory for DALI Lumentalk applications.• ASHRAE version: 5 watts per foot [0.3m], Regular Output version: 8.5 watts per foot [0.3m], High Output version: 15.25 watts per foot [0.3m]. TYPICAL WIRING DIAGRAMS - continued A - Power input (control over power line via Lumentalk system)B - To fixtureC - To Lumentalk Data Bridge (for run lengths with 1' fixtures [0.3m])D - LineE - GroundF - NeutralG - Wire-nuts (by others)H - Junction box (by others)A B C H DEF G GS - R64 10/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS 0-10V Dimming (DIM) 10% minimum dimming value A - Power input (100-277V)B - Third party dimmer C - Data wiring (by others)D - Junction box (by others)E - Leader cable (LOGLC)F - Lumenfacade (LOG-DIM) G - Jumper cable (LOGJC)H - Sealing end cap 0-10V Dimming (DIM) - Wiring detail Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations.• 0-10V mA ratings: passive dimmer (Current Sink): 3mA per fixture, active dimmer (Current Source): 0.5mA per fixture.• ASHRAE version: 5 watts per foot [0.3m], Regular Output version: 8.5 watts per foot [0.3m], High Output version: 15.25 watts per foot [0.3m]. DALI Dimming (DALI) 1% dimming value Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations.• Maximum of 64 DALI fixtures per DALI loop.• ASHRAE version: 5 watts per foot [0.3m], Regular Output version: 8.5 watts per foot [0.3m], High Output version: 15.25 watts per foot [0.3m]. DALI Dimming (DALI) - Wiring detail A - Power input (100-277V)B - Third party DALI controllerC - Data wiring (by others)D - Junction box (by others)E - Leader cable (LOGLC)F - Lumenfacade (LOG-DALI)G - Jumper cable (LOGJC)H - Sealing end cap Wiring Color Code AmericanColor Code CEColor Code Black Brown Red/Purple BlackOrangeGrey White Blue USE Live 100-277V 0-10V / Data + Green Yellow/Green Ground 0-10V / Data - Neutral A B C H D E FG IJ A - Power inputB - From DALI controllerC - Data +D - Data -E - To fixtureF - LineG - GroundH - NeutralI - Wire-nuts (by others)J - Junction box (by others) A B C H D E FG IJ A - Power inputB - From third party dimmerC - 0-10V +D - 0-10V -E - To fixtureF - LineG - GroundH - NeutralI - Wire-nuts (by others)J - Junction box (by others) A B C E G HDF A B C EDE G HF TYPICAL WIRING DIAGRAMS - continued GS - R64 11/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS Wiring Color Code AmericanColor Code CEColor Code Black Brown Red/Purple BlackOrangeGrey White Blue USE Live 100-277V 0-10V / Data + Green Yellow/Green Ground 0-10V / Data - Neutral Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations.• Each Lutron® EcoSystem® enabled fixture has its own address;  for the example shown, there are a total of 2 EcoSystem® addresses.• ASHRAE version: 5 watts per foot [0.3m], Regular Output version: 8.5 watts per foot [0.3m], High Output version: 15.25 watts per foot [0.3m]. Lutron® EcoSystem® Enabled Dimming (ES) 1% minimum dimming value Lutron® EcoSystem® EnabledDimming (ES) - Wiring detail A - Power input (100-277V)B - Lutron® EcoSystem® controller C - Data wiring (by others)D - Junction box (by others)E - Leader cable (LOGLC)F - Lumenfacade (LOG-ES) (2, 3,or 4ft fixture lengths) [0.6, 0.9,1or 1.2m]G - Jumper cable (LOGJC)H - Sealing end cap A B C H D E FG IJ A - Power inputB - From Lutron® EcoSystem® controller C - Data +D - Data -E - To fixtureF - LineG - GroundH - NeutralI - Wire-nuts (by others)J - Junction box (by others) A B C EDE G HF TYPICAL WIRING DIAGRAMS - continued GS - R64 12/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS TYPICAL WIRING DIAGRAMS - continued American Color Code CE Color Code Black Brown Red/Purple BlackOrangeGrey White Blue USE Live 100-277V 0-10V / Data + Green Yellow/Green Ground 0-10V / Data - Neutral A - Third party DMX/RDM controllerB - Data input (Belden 9841 or equivalent, by others)C - Data output to next CBX (optional, not isolated/not boosted)D - CBX-ST E - Power input (100-277V)F - Leader cable (LOGLC)G - Lumenfacade (LOG-DMX/RDM)H - Jumper cable (LOGJC)I - Sealing end cap A - Third party DMX/RDM controllerB - Data input (Belden 9841 or equivalent, by others)C - Data output to next CBX (optional, not isolated/not boosted)D - CBX-DS E - Power input (100-277V)F - Leader cable (LOGLC)G - Lumenfacade (LOG-DMX/RDM)H - Jumper cable (LOGJC)I - Sealing end cap A D C E B F H IG B ECD A F H IG Star Layout (DMX/RDM) 1% minimum dimming value Daisy Chain Layout (DMX/RDM)1% minimum dimming value Maximum run length by 15A circuit - Lumenfacade™ HO 15.25W/ft [0.3m] Cable length/Voltage 120V 240V 277V 50ft [15m] leader cable Maximum run length by 15A circuit - Lumenfacade™ RO 8.5W/ft [0.3m] 50ft [15m] leader cable Maximum run length by 15A circuit - Lumenfacade™ ASHRAE 5W/ft [0.3m] 50ft [15m] leader cable 68ft [21m]76ft [23m]84ft [26m] 120ft [37m]128ft [39m]128ft [39m] 128ft [39m]128ft [39m]128ft [39m] Notes: • Consult factory for specific applications and maximum fixture count/cable length recommendations. Maximum run length calculations are typically based on 4' [1.2m] fixtures.• Maximum of 32 DMX/RDM enabled fixtures per CBX output.• Maximum of 4 DMX/RDM repeaters/CBX cascading in line.• Maximum of 6 outputs per CBX-ST, maximum of 1output per CBX-DS• Each fixture requires 1 DMX address.• ASHRAE version: 5 watts per foot [0.3m], Regular Output version: 8.5 watts per foot [0.3m], High Output version: 15.25 watts per foot [0.3m]. GS - R64 13/13 2017.03.30 5-year limited warranty. Consult www.lumenpulsegroup.com for our complete Standard Terms and Conditions of Sales. © Copyright Lumenpulse 2017 1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P.514.937.3003 F. 514.937.6289 info@lumenpulse.com www.lumenpulsegroup.com Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modication shall be effective immediately. Specification Sheet lumenfacade™ WHITE & STATIC COLORS LOG 1 2 3 4 5 6 7 8 9 HOW TO ORDER Notes: 1  Not available for 1' [0.3m] fixture lengths. 2  Right feeding side is standard unless otherwise specified. 3  For best results use with HO fixtures at a 6-inch (15cm) setback from surface. Contact factory for application support. 4 Suitable to use when 3GV option is specified. 5  North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or to match alternate color charts. Final color matching results may vary. 6 Lumentalk system is enabled with LDB accessory for 1' [0.3m] fixture lengths, see Typical Wiring Diagrams pages for details. 1% minimum dimming value. 7 10% minimum dimming value. Current Sink: 3mA/fixture, Current Source: 0.5mA/fixture. 8 1% minimum dimming value. 1 DALI address per fixture. 9 Available for 2' RO [0.6m], 3' [0.9m] and 4' [1.2m] fixture lengths only. 1% minimum dimming value. 1 EcoSystem® address per fixture length. 10 1% minimum dimming value. Fixtures set to by fixture resolution. 1 DMX address per fixture. 11 Available with UMP and UMAS mounting options only. 1 Housing: LOG ASHRAE - Lumenfacade™, 5W/ft  ASHRAE compliant1 LOG RO - Lumenfacade™ Regular Output, 8.5W/ft  LOG HO - Lumenfacade™ High Output, 15.25W/ft 2 Voltage: 100 - 100 volts 120 - 120 volts 208 - 208 volts 220 - 220 volts 240 - 240 volts 277 - 277 volts 3 Length: 12 - 13 3/8 inches (340mm) (2 kg/4.5 lbs) 24 - 25 3/8 inches (645mm) (3.17 kg/7 lbs) 36 - 37 3/8 inches (949mm) (4.75 kg/10.5 lbs) 48 - 49 3/8 inches (1254mm) (6.35 kg/14 lbs) 4 Colors and Color temperatures: 22K - 2200K 27K - 2700K 30K - 3000K 35K - 3500K 40K - 4000K RD - Red GR - Green BL - Blue Consult factory for availability of static Royal Blue, 6500K and 90+ CRI. 5 Optics: Asymmetric WWLF - Asymmetric Wallwash optic, left feed2 WWRF - Asymmetric Wallwash optic, right feed2 Symmetric 8x8 - 8° x 8°3 10x10 - 10° x 10°3 30x30 - 30° x 30° 35x35 - 35° x 35° 60x60 - 60° x 60° 80x80 - 80° x 80° 90x90 - 90° x 90° Bi-symmetric 10x30 - 10° x 30° 10x60 - 10° x 60° 10x90 - 10° x 90° 15x25 - 15° x 25° 30x60 - 30° x 60° 50x80 - 50° x 80° 6 Mounting Option: SAM - Slim Adjustable Mounting UMP - Fixed Mounting4 UMAS - Universal Adjustable Mounting4 WAM2 - Adjustable Wall Mounting 2" WAM6 - Adjustable Extended Arm Mounting 6" WAM12 - Adjustable Extended Arm Mounting 12" WAM18 - Adjustable Extended Arm Mounting 18" 7 Finish: BK - Black Sandtex BRZ - Bronze Sandtex SI - Silver Sandtex WH - Smooth white CC - Custom color and finish (please specify RAL color)5 8 Control: NO - No Dimming LT - Lumentalk Dimming6 DIM - 0-10V Dimming option7 DALI - DALI Dimming option8 ES - Lutron® EcoSystem® Enabled Dimming9 DMX/RDM - DMX/RDM enabled10 9 Option: ETE - End - to - end configuration, 16" black input cable, no jumper cable needed CRC - Corrosion-resistant coating for hostile environments 3GV - 3G ANSI C136.31 Vibration Rating11 CE - CE (certification covers European Economic Area)