B16-0491_A500_1501518283.pdf
4 - LEVEL 3 8,197' - 9 5/8" NEW JELD-WEN WINDOW/ DOOR UNIT VYCOR FLASHING 5/8" EXTERIOR GYP SHEATHING WEATHER RESISTIVE BARRIER CAULK JOINT INTERIOR TRIM 3/8" STANDARD GAP W/ SPRAY FOAM ALL SIDES 2X4 HEAD BUCKING 3 COAT STUCCO SYSTEM DECK ROOF WITH STANDING SEAM METAL ROOF AND T&G SOFFIT 5/8" INTERIOR GYP. 2X4 FRAMING WALL INSULATION HEADER BLOCKING T R I M DOOR STOP JAMB EXTERIOR GRADE OSB STUCCO METAL FLASHING 1 - CREEK LEVEL 8,168' - 6 5/8" SWING DOOR THRESHOLD FINISH FLOOR SUBFLOOR INSULATION FLOOR LEVELING LOWER LEVEL SLAB FLAGSTONE PATIO ON 6" CONCRETE PAD 5 - ROOF 8,208' - 6 5/8" VAPOR BARRIER GRID R-21 BATT INSULATION STUCCO SYSTEM 2" R-9 CONTINUOUS RIGID INSULATION FLUID-APPLIED AIR/WATER BARRIER 5/8" GLASS-MAT GYPSUM, WATER- RESISTANT WALL SHEATHING 5/8" INTERIOR GYPSUM BOARD, TYPE X WOOD OR METAL FRAMING VAPOR BARRIER GRID R-19 BATT INSULATION STUCCO SYSTEM 2" R-9 CONTINUOUS RIGID INSULATION FLUID-APPLIED AIR/WATER BARRIER 5/8" GLASS-MAT GYPSUM, WATER- RESISTANT WALL SHEATHING 5/8" INTERIOR GYPSUM BOARD, TYPE X FULLY GROUTED EXISTING MASONRY BLOCK PARTY WALL INTERIOR FURRING WALL 2 - STREET LEVEL 8,178' - 2 3/8" VAPOR BARRIER GRID R-19 BATT INSULATION FLUID-APPLIED AIR/WATER BARRIER 5/8" GLASS-MAT GYPSUM, WATER- RESISTANT WALL SHEATHING 5/8" INTERIOR GYPSUM BOARD, TYPE X FULLY GROUTED EXISTING MASONRY BLOCK PARTY WALL INTERIOR FURRING WALL INTERIOR FURRING WALL 5/8" INTERIOR GYPSUM BOARD, TYPE X GRID RIM JOISTS; RE: STRUCT STAINLESS STEEL PAN FLASHING WITH END DAMS FULLY SOLDERED TIGHT EXISTING PAVER TERRACE GYP CEILING SOUTH TERRACE SOUTH BEDROOM LIVING ROOM GRID RIM JOISTS; RE: STRUCT STAINLESS STEEL PAN FLASHING WITH END DAMS FULLY SOLDERED TIGHT TREX COMPOSITE DECKING NORTH DECK KITCHEN/ BEDROOM 2 - STREET LEVEL 8,178' - 2 3/8" 5 - ROOF 8,208' - 6 5/8" 2 " Project number Date Drawn by 12/2/2016 3:39:57 PM A500 EXTERIOR DETAILS 000000 VAIL ROWHOUSES, VAIL COLORADO ROW HOUSE 11 12/2/2016 Author 3" = 1'-0"1 TYPICAL WINDOW HEAD AT STUCCO No. Description Date 1 PERMIT SUBMITTAL 12 DEC 16 3" = 1'-0" 2 TYPICAL DOOR HEAD AT STUCCO 3" = 1'-0" 3 TYPICAL DOOR SLIDE AT FLAGSTONE PATIO 1 1/2" = 1'-0" 4 TYPICAL WINDOW HEAD AT ROOF SOFFIT 3" = 1'-0" 5 TYPICAL WINDOW SILL AT STUCCO 3" = 1'-0" 6 TYPICAL EXTERIOR STUCCO WALL 3" = 1'-0" 7 TYPICAL NEW INSULATED EXISTING PARTY WALL - EXPOSED EXTERIOR 3" = 1'-0" 8 TYPICAL EXISTING PARTY WALL - INTERIOR ENCLOSED 3" = 1'-0" 9 TYPICAL DOOR SILL AT SOUTH TERRACE 3" = 1'-0" 10 TYPICAL DOOR SILL AT NORTH DECKS 3" = 1'-0" 11 NORTH DECK EDGE 1 1/2" = 1'-0" 12 TYPICAL WINDOW HEAD AT NORTH DECK ROOF 07/31/17