Room Checksums By BGCE 1 - Entry HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 0 / 0 Mo/Hr: 0 / 0 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 0 / 0 / 0 OADB/WB/HR: Outside Air: 0.0 125.0 Ra Plenum 0.0 67.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 0.0 68.0 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 68.0 0.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond -532 60.10 -532 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 43.85 -388 -341 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 103.94 0 Sub Total ==> -919 -873 0 0 0 0 0 0 Return 17 Internal Loads 0 0 Exhaust 0 Lights 0.00 0 0 0 0 0 0 0 0 0 Rm Exh 0 People 0.00 0 0 0 0 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 0 Sub Total ==> 0.00 0 0 0 0 0 0 0 0 Ceiling Load 0.00 0 -12 0 0 0 0 0 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.15 0.00 cfm/ft² 0 Ov/Undr Sizing 0.00 0 0 0 0 0 0 0.00 cfm/ton Exhaust Heat 0.00 0 0 0 0.00 ft²/ton -7.69 0.00 Btu/hr·ft² 0.6 No. People 0 Grand Total ==> 100.00 -885 -885 100.00 0 100.00 0 0 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 115 Main Htg -0.9 17 68.0 125.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 117 20 17 Humidif 0.0 0 0.0 0.0 0.0 0.0 Total Opt Vent 0.0 0.0 0.0 0 -0.9 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 35 0 0 0.00 -3.94 0.00 0.00 0 Supply Air Leakage 0 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 0 0 0 0 0 0 0 0 17 17 17 0 0 0 0 0 0 0 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 1 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 1 - Hall HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 0 / 0 Mo/Hr: 0 / 0 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 0 / 0 / 0 OADB/WB/HR: Outside Air: 0.0 125.0 Ra Plenum 0.0 67.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 0.0 68.0 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 68.0 0.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 0.00 0 Sub Total ==> 0 0 0 0 0 0 0 0 Return 1 Internal Loads 0 0 Exhaust 0 Lights 0.00 0 0 0 0 0 0 0 0 0 Rm Exh 0 People 0.00 0 0 0 0 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 0 Sub Total ==> 0.00 0 0 0 0 0 0 0 0 Ceiling Load 0.00 0 -25 0 0 0 0 0 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.00 0.00 cfm/ft² 0 Ov/Undr Sizing 0.00 0 0 0 0 0 0 0.00 cfm/ton Exhaust Heat 0.00 0 0 0 0.00 ft²/ton -0.10 0.00 Btu/hr·ft² 1.2 No. People 0 Grand Total ==> 100.00 -25 -25 100.00 0 100.00 0 0 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 248 Main Htg 0.0 1 68.0 125.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.0 Total Opt Vent 0.0 0.0 0.0 0 0.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -25 0 0 0.00 100.00 0.00 0.00 0 Supply Air Leakage 0 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 0 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0 0 0 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 2 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 1 - North bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 19 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.1 67.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.1 67.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.7 75.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 0.00 0 Sub Total ==> 0 0 0 0 0 0 0 30 Return 30 Internal Loads 0 0 Exhaust 425 Lights 0.00 0 0 80 425 75 425 0 0 0 Rm Exh 145 People 0.00 0 19 102 25 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 570 Sub Total ==> 0.00 0 0 99 527 100 570 0 2 Ceiling Load 0.00 0 -8 1 3 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.36 0.36 cfm/ft² 0 Ov/Undr Sizing 97.78 -707 -707 0 0 0 0 625.20 cfm/ton Exhaust Heat 0.00 0 0 0 1,746.82 ft²/ton -8.71 6.87 Btu/hr·ft² 0.4 No. People 572 Grand Total ==> 100.00 -723 -715 100.00 529 100.00 570 -2 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 83 Main Htg -0.7 30 67.7 95.0 0.1 0.6 0.5 30 75.1 59.3 68.9 55.0 51.8 66.6 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.6 Total Opt Vent 0.0 0.0 0.0 0 -0.7 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -16 0 0 0.00 2.22 0.00 0.00 0 Supply Air Leakage 80 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 30 30 30 0 0 0 0 0 30 30 30 0 0 0 0 0 0 145 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 3 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 1 - North bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 16 Mo/Hr: 7 / 16 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 87 / 74 / 141 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.1 67.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.1 67.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.7 75.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 1,087 Glass Solar 0 0 31 1,087 29 1,087 0 236 Glass/Door Cond -1,748 36.25 -1,748 7 236 6 236 0 AIRFLOWS Heating Cooling 183 Wall Cond 15.44 -745 -644 5 183 6 212 29 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 51.69 1,505 Sub Total ==> -2,492 -2,392 43 1,505 41 1,534 29 198 Return 198 Internal Loads 0 0 Exhaust 1,628 Lights 0.00 0 0 46 1,628 44 1,628 0 0 0 Rm Exh 557 People 0.00 0 11 390 15 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 2,185 Sub Total ==> 0.00 0 0 57 2,018 59 2,185 0 9 Ceiling Load 0.00 0 -31 0 9 0 0 -9 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.62 0.62 cfm/ft² 0 Ov/Undr Sizing 48.64 -2,345 -2,345 0 0 0 0 639.43 cfm/ton Exhaust Heat 0.00 0 0 0 1,026.23 ft²/ton -15.16 11.69 Btu/hr·ft² 1.6 No. People 3,699 Grand Total ==> 100.00 -4,822 -4,768 100.00 3,532 100.00 3,718 20 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 318 Main Htg -4.8 198 67.7 95.0 0.3 3.7 3.6 198 75.1 58.8 66.4 55.0 51.4 64.9 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 252 66 26 Humidif 0.0 0 0.0 0.0 0.3 3.7 Total Opt Vent 0.0 0.0 0.0 0 -4.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 16 0 0 0.00 -0.33 0.00 0.00 0 Supply Air Leakage 87 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 198 198 198 0 0 0 0 0 198 198 198 0 0 0 0 0 0 557 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 4 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 1 - South bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 17 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.1 67.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.1 67.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.8 75.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 0.00 0 Sub Total ==> 0 0 0 0 0 0 0 35 Return 35 Internal Loads 0 0 Exhaust 497 Lights 0.00 0 0 80 497 75 497 0 0 0 Rm Exh 170 People 0.00 0 19 119 25 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 666 Sub Total ==> 0.00 0 0 100 615 100 666 0 2 Ceiling Load 0.00 0 -6 0 3 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.36 0.36 cfm/ft² 0 Ov/Undr Sizing 98.51 -828 -828 0 0 0 0 624.61 cfm/ton Exhaust Heat 0.00 0 0 0 1,746.82 ft²/ton -8.67 6.87 Btu/hr·ft² 0.5 No. People 669 Grand Total ==> 100.00 -841 -835 100.00 618 100.00 666 -2 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 97 Main Htg -0.8 35 67.8 95.0 0.1 0.7 0.6 35 75.1 59.3 68.9 55.0 51.8 66.6 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.7 Total Opt Vent 0.0 0.0 0.0 0 -0.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -13 0 0 0.00 1.49 0.00 0.00 0 Supply Air Leakage 86 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 35 35 35 0 0 0 0 0 35 35 35 0 0 0 0 0 0 170 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 5 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 1 - South bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 10 / 15 Mo/Hr: 10 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 52 / 40 / 28 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 67.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 67.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.8 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 3,286 Glass Solar 0 0 79 3,286 77 3,286 0 -360 Glass/Door Cond -1,263 22.40 -1,263 -9 -360 -8 -360 0 AIRFLOWS Heating Cooling 73 Wall Cond 8.44 -476 -409 2 73 2 85 12 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 30.84 2,999 Sub Total ==> -1,738 -1,672 72 2,999 71 3,011 12 232 Return 232 Internal Loads 0 0 Exhaust 922 Lights 0.00 0 0 22 922 22 922 0 0 0 Rm Exh 315 People 0.00 0 5 221 7 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,237 Sub Total ==> 0.00 0 0 28 1,142 29 1,237 0 2 Ceiling Load 0.00 0 -12 0 2 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 1.29 1.29 cfm/ft² 0 Ov/Undr Sizing 69.38 -3,910 -3,910 0 0 0 0 656.72 cfm/ton Exhaust Heat 0.00 0 0 0 508.52 ft²/ton -31.31 23.60 Btu/hr·ft² 0.9 No. People 4,238 Grand Total ==> 100.00 -5,636 -5,594 100.00 4,143 100.00 4,248 10 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 180 Main Htg -5.6 232 67.8 95.0 0.4 4.3 4.2 232 75.0 58.0 62.9 55.0 50.7 62.1 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 167 48 29 Humidif 0.0 0 0.0 0.0 0.4 4.3 Total Opt Vent 0.0 0.0 0.0 0 -5.6 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 13 0 0 0.00 -0.22 0.00 0.00 0 Supply Air Leakage 52 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 232 232 232 0 0 0 0 0 232 232 232 0 0 0 0 0 0 315 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 6 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 2 - Dining room HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.1 67.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.1 67.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.8 75.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 1,388 Glass Solar 0 0 43 1,388 41 1,388 0 271 Glass/Door Cond -2,140 48.70 -2,140 8 271 8 271 0 AIRFLOWS Heating Cooling 140 Wall Cond 16.02 -704 -601 4 140 5 164 24 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 64.71 1,799 Sub Total ==> -2,843 -2,741 56 1,799 54 1,823 24 181 Return 181 Internal Loads 0 0 Exhaust 1,147 Lights 0.00 0 0 36 1,147 34 1,147 0 0 0 Rm Exh 392 People 0.00 0 9 274 12 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,539 Sub Total ==> 0.00 0 0 44 1,421 46 1,539 0 4 Ceiling Load 0.00 0 -18 0 4 0 0 -4 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.81 0.81 cfm/ft² 0 Ov/Undr Sizing 36.30 -1,595 -1,595 0 0 0 0 645.75 cfm/ton Exhaust Heat 0.00 0 0 0 799.51 ft²/ton -19.61 15.01 Btu/hr·ft² 1.1 No. People 3,342 Grand Total ==> 100.00 -4,394 -4,353 100.00 3,225 100.00 3,362 20 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 224 Main Htg -4.4 181 67.8 95.0 0.3 3.4 3.2 181 75.1 58.5 65.0 55.0 51.1 63.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 257 81 31 Humidif 0.0 0 0.0 0.0 0.3 3.4 Total Opt Vent 0.0 0.0 0.0 0 -4.4 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 44 0 0 0.00 -1.01 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 181 181 181 0 0 0 0 0 181 181 181 0 0 0 0 0 0 392 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 7 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 2 - Kitchen HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 19 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.1 67.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.1 67.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.8 75.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 0.00 0 Sub Total ==> 0 0 0 0 0 0 0 119 Return 119 Internal Loads 0 0 Exhaust 1,157 Lights 0.00 0 0 54 1,157 52 1,157 0 0 0 Rm Exh 396 People 0.00 0 13 277 18 0 0 Auxiliary 683 Misc 0.00 0 0 32 683 31 683 0 2,235 Sub Total ==> 0.00 0 0 100 2,116 100 2,235 0 4 Ceiling Load 0.00 0 -18 0 7 0 0 -4 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.53 0.53 cfm/ft² 0 Ov/Undr Sizing 98.47 -2,848 -2,848 0 0 0 0 639.50 cfm/ton Exhaust Heat 0.00 0 0 0 1,213.36 ft²/ton -12.80 9.89 Btu/hr·ft² 1.1 No. People 2,239 Grand Total ==> 100.00 -2,893 -2,866 100.00 2,123 100.00 2,235 -4 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 226 Main Htg -2.9 119 67.8 95.0 0.2 2.2 2.1 119 75.1 58.9 67.1 55.0 51.6 65.5 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.2 2.2 Total Opt Vent 0.0 0.0 0.0 0 -2.9 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -44 0 0 0.00 1.53 0.00 0.00 0 Supply Air Leakage 80 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 119 119 119 0 0 0 0 0 119 119 119 0 0 0 0 0 0 396 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 8 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 2 - Living room HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 10 / 15 Mo/Hr: 10 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 52 / 40 / 28 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.4 66.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.4 66.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 66.7 75.4 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 4.88 -759 0 0 0 2 245 245 0.00 9,058 Glass Solar 0 0 82 9,058 79 9,058 0 -981 Glass/Door Cond -3,346 21.48 -3,346 -9 -981 -9 -981 0 AIRFLOWS Heating Cooling 187 Wall Cond 5.23 -814 -685 2 187 2 222 35 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 31.58 8,264 Sub Total ==> -4,920 -4,030 75 8,264 75 8,543 280 618 Return 618 Internal Loads 0 0 Exhaust 2,171 Lights 0.00 0 0 20 2,171 19 2,171 0 0 0 Rm Exh 742 People 0.00 0 5 519 6 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 2,913 Sub Total ==> 0.00 0 0 24 2,690 25 2,913 0 55 Ceiling Load 0.00 0 -175 0 55 0 0 -55 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 1.46 1.46 cfm/ft² 0 Ov/Undr Sizing 68.42 -10,657 -10,657 0 0 0 0 646.94 cfm/ton Exhaust Heat 0.00 0 0 0 444.13 ft²/ton -36.74 27.02 Btu/hr·ft² 2.1 No. People 11,231 Grand Total ==> 100.00 -15,576 -14,861 100.00 11,009 100.00 11,456 225 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 424 Main Htg -15.6 618 66.7 95.0 1.0 11.5 11.2 618 75.4 58.1 62.4 55.0 50.6 61.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 450 0 0 Wall 330 126 38 Humidif 0.0 0 0.0 0.0 1.0 11.5 Total Opt Vent 0.0 0.0 0.0 0 -15.6 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 0 0 0 0.00 0.00 0.00 0.00 0 Supply Air Leakage 52 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 618 618 618 0 0 0 0 0 618 618 618 0 0 0 0 0 0 742 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 9 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 3 - Bathroom/storage HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 17 Mo/Hr: 7 / 17 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 86 / 73 / 135 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.6 67.2 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.6 67.2 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.2 75.6 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 20.40 -305 0 0 0 17 235 235 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 20.40 0 Sub Total ==> -305 0 0 0 17 235 235 60 Return 60 Internal Loads 0 0 Exhaust 845 Lights 0.00 0 0 79 845 62 845 0 0 0 Rm Exh 289 People 0.00 0 19 202 21 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,133 Sub Total ==> 0.00 0 0 97 1,047 83 1,133 0 29 Ceiling Load 0.00 0 -44 3 29 0 0 -29 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.37 0.37 cfm/ft² 0 Ov/Undr Sizing 94.07 -1,409 -1,409 0 0 0 0 529.32 cfm/ton Exhaust Heat 0.00 0 0 0 1,446.97 ft²/ton -9.08 8.29 Btu/hr·ft² 0.8 No. People 1,162 Grand Total ==> 100.00 -1,497 -1,452 100.00 1,076 100.00 1,368 206 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 165 Main Htg -1.5 60 67.2 95.0 0.1 1.4 1.3 60 75.6 59.4 68.8 55.0 50.5 61.1 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 180 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 1.4 Total Opt Vent 0.0 0.0 0.0 0 -1.5 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 217 0 0 0.00 -14.47 0.00 0.00 0 Supply Air Leakage 86 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 60 60 60 0 0 0 0 0 60 60 60 0 0 0 0 0 0 289 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 10 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE 3 - Bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 16 Mo/Hr: 7 / 16 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 87 / 74 / 141 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 76.7 65.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 76.7 65.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 65.7 76.7 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 9.83 -417 0 0 0 11 354 354 0.00 1,000 Glass Solar 0 0 35 1,000 31 1,000 0 202 Glass/Door Cond -1,595 37.64 -1,595 7 202 6 202 0 AIRFLOWS Heating Cooling 143 Wall Cond 14.46 -613 -530 5 143 5 165 21 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 61.93 1,345 Sub Total ==> -2,624 -2,124 47 1,345 53 1,721 376 162 Return 162 Internal Loads 0 0 Exhaust 1,147 Lights 0.00 0 0 40 1,147 35 1,147 0 0 0 Rm Exh 392 People 0.00 0 9 274 12 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,539 Sub Total ==> 0.00 0 0 49 1,421 47 1,539 0 124 Ceiling Load 0.00 0 -165 4 124 0 0 -124 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.72 0.72 cfm/ft² 0 Ov/Undr Sizing 38.07 -1,613 -1,613 0 0 0 0 596.91 cfm/ton Exhaust Heat 0.00 0 0 0 824.53 ft²/ton -18.92 14.55 Btu/hr·ft² 1.1 No. People 3,008 Grand Total ==> 100.00 -4,237 -3,902 100.00 2,890 100.00 3,260 252 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 224 Main Htg -4.2 162 65.7 95.0 0.3 3.3 3.1 162 76.7 59.2 65.7 55.0 51.3 64.4 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 250 0 0 Wall 214 60 28 Humidif 0.0 0 0.0 0.0 0.3 3.3 Total Opt Vent 0.0 0.0 0.0 0 -4.2 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 0 0 0 0.00 0.00 0.00 0.00 0 Supply Air Leakage 87 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 162 162 162 0 0 0 0 0 162 162 162 0 0 0 0 0 0 392 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 11 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE B - Bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 17 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.5 67.2 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.5 67.2 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.2 75.5 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 -13 Partition/Door 23.03 -100 -100 -4 -13 -4 -13 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 23.03 -13 Sub Total ==> -100 -100 -4 -13 -4 -13 0 18 Return 18 Internal Loads 0 0 Exhaust 256 Lights 0.00 0 0 82 256 78 256 0 0 0 Rm Exh 88 People 0.00 0 20 61 26 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 343 Sub Total ==> 0.00 0 0 101 317 104 343 0 8 Ceiling Load 0.00 0 -13 3 9 0 0 -8 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.35 0.35 cfm/ft² 0 Ov/Undr Sizing 70.91 -309 -309 0 0 0 0 637.66 cfm/ton Exhaust Heat 0.00 0 0 0 1,816.71 ft²/ton -8.71 6.61 Btu/hr·ft² 0.3 No. People 338 Grand Total ==> 100.00 -435 -422 100.00 313 100.00 330 -8 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 50 Main Htg -0.4 18 67.2 95.0 0.0 0.3 0.3 18 75.5 59.4 69.0 55.0 52.1 68.0 Main Clg Part 50 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.3 Total Opt Vent 0.0 0.0 0.0 0 -0.4 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -26 0 0 0.00 6.06 0.00 0.00 0 Supply Air Leakage 86 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 18 18 18 0 0 0 0 0 18 18 18 0 0 0 0 0 0 88 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 12 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE B - Bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.5 67.2 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.5 67.2 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.2 75.5 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 1,282 Glass Solar 0 0 39 1,282 37 1,282 0 250 Glass/Door Cond -1,977 42.89 -1,977 8 250 7 250 0 AIRFLOWS Heating Cooling 115 Wall Cond 12.27 -566 -480 3 115 4 136 20 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 4.37 -202 -202 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 59.54 1,648 Sub Total ==> -2,744 -2,659 50 1,648 49 1,669 20 186 Return 186 Internal Loads 0 0 Exhaust 1,311 Lights 0.00 0 0 40 1,311 38 1,311 0 0 0 Rm Exh 448 People 0.00 0 9 314 13 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,759 Sub Total ==> 0.00 0 0 49 1,624 51 1,759 0 39 Ceiling Load 0.00 0 -68 1 39 0 0 -39 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.73 0.73 cfm/ft² 0 Ov/Undr Sizing 37.83 -1,743 -1,743 0 0 0 0 650.44 cfm/ton Exhaust Heat 0.00 0 0 0 896.38 ft²/ton -18.00 13.39 Btu/hr·ft² 1.3 No. People 3,445 Grand Total ==> 100.00 -4,609 -4,470 100.00 3,311 100.00 3,427 -18 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 256 Main Htg -4.6 186 67.2 95.0 0.3 3.4 3.3 186 75.5 58.7 65.7 55.0 51.5 65.3 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 24 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 216 74 34 Humidif 0.0 0 0.0 0.0 0.3 3.4 Total Opt Vent 0.0 0.0 0.0 0 -4.6 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -121 0 0 0.00 2.63 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 186 186 186 0 0 0 0 0 186 186 186 0 0 0 0 0 0 448 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 13 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE B - Closet HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 17 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.5 67.2 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.5 67.2 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.2 75.5 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 0.00 0 Sub Total ==> 0 0 0 0 0 0 0 19 Return 19 Internal Loads 0 0 Exhaust 266 Lights 0.00 0 0 79 266 75 266 0 0 0 Rm Exh 91 People 0.00 0 19 64 25 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 357 Sub Total ==> 0.00 0 0 97 330 100 357 0 8 Ceiling Load 0.00 0 -14 3 9 0 0 -8 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.37 0.37 cfm/ft² 0 Ov/Undr Sizing 94.07 -444 -444 0 0 0 0 639.03 cfm/ton Exhaust Heat 0.00 0 0 0 1,746.79 ft²/ton -9.08 6.87 Btu/hr·ft² 0.3 No. People 365 Grand Total ==> 100.00 -472 -458 100.00 339 100.00 357 -8 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 52 Main Htg -0.5 19 67.2 95.0 0.0 0.4 0.3 19 75.5 59.4 68.8 55.0 52.1 67.8 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.4 Total Opt Vent 0.0 0.0 0.0 0 -0.5 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -28 0 0 0.00 5.93 0.00 0.00 0 Supply Air Leakage 86 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 19 19 19 0 0 0 0 0 19 19 19 0 0 0 0 0 0 91 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 14 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE B - Mechanical HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 0 / 0 Mo/Hr: 0 / 0 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 0 / 0 / 0 OADB/WB/HR: Outside Air: 0.0 125.0 Ra Plenum 0.0 67.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 0.0 68.0 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 68.0 0.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 69.58 -521 -521 0 0 0 0 0 Floor 29.14 -218 -218 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 98.72 0 Sub Total ==> -740 -740 0 0 0 0 0 0 Return 15 Internal Loads 0 0 Exhaust 0 Lights 0.00 0 0 0 0 0 0 0 0 0 Rm Exh 0 People 0.00 0 0 0 0 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 0 Sub Total ==> 0.00 0 0 0 0 0 0 0 0 Ceiling Load 0.00 0 -10 0 0 0 0 0 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.16 0.00 cfm/ft² 0 Ov/Undr Sizing 0.00 0 0 0 0 0 0 0.00 cfm/ton Exhaust Heat 0.00 0 0 0 0.00 ft²/ton -7.97 0.00 Btu/hr·ft² 0.5 No. People 0 Grand Total ==> 100.00 -749 -749 100.00 0 100.00 0 0 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 94 Main Htg -0.8 15 68.0 125.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Main Clg Part 260 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 26 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.0 Total Opt Vent 0.0 0.0 0.0 0 -0.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -10 0 0 0.00 1.28 0.00 0.00 0 Supply Air Leakage 0 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 0 0 0 0 0 0 0 0 15 15 15 0 0 0 0 0 0 0 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 15 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE B - Stair/hall HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 17 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 88 / 75 / 144 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.5 67.2 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.5 67.2 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.2 75.5 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 0.00 0 Sub Total ==> 0 0 0 0 0 0 0 31 Return 31 Internal Loads 0 0 Exhaust 430 Lights 0.00 0 0 79 430 75 430 0 0 0 Rm Exh 147 People 0.00 0 19 103 25 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 577 Sub Total ==> 0.00 0 0 97 533 100 577 0 13 Ceiling Load 0.00 0 -22 3 15 0 0 -13 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.37 0.37 cfm/ft² 0 Ov/Undr Sizing 94.07 -717 -717 0 0 0 0 639.02 cfm/ton Exhaust Heat 0.00 0 0 0 1,746.81 ft²/ton -9.08 6.87 Btu/hr·ft² 0.4 No. People 590 Grand Total ==> 100.00 -762 -739 100.00 548 100.00 577 -13 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 84 Main Htg -0.8 31 67.2 95.0 0.1 0.6 0.5 31 75.5 59.4 68.8 55.0 52.1 67.8 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.6 Total Opt Vent 0.0 0.0 0.0 0 -0.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -45 0 0 0.00 5.93 0.00 0.00 0 Supply Air Leakage 86 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 31 31 31 0 0 0 0 0 31 31 31 0 0 0 0 0 0 147 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 16 of 17 9762ROWHOUSE11.TRC 07/31/17 Room Checksums By BGCE B - Storage HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 19 Mo/Hr: 7 / 19 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -16 OADB: 80 / 70 / 119 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.5 67.2 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.5 67.2 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 67.2 75.5 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 39 Wall Cond 72.41 -144 -130 27 39 28 43 4 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 16.91 -34 -34 0 0 0 Sec Fan 0.00 0 Infiltration 0 0 0 0 0 0 0 0 MinStop/Rh 89.32 39 Sub Total ==> -177 -163 27 39 28 43 4 8 Return 8 Internal Loads 0 0 Exhaust 82 Lights 0.00 0 0 57 82 54 82 0 0 0 Rm Exh 28 People 0.00 0 14 20 18 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 110 Sub Total ==> 0.00 0 0 71 102 72 110 0 2 Ceiling Load 0.00 0 -4 2 2 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.50 0.50 cfm/ft² 0 Ov/Undr Sizing 12.70 -25 -25 0 0 0 0 628.40 cfm/ton Exhaust Heat 0.00 0 0 0 1,255.61 ft²/ton -12.42 9.56 Btu/hr·ft² 0.1 No. People 151 Grand Total ==> 100.00 -199 -193 100.00 143 100.00 153 2 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 16 Main Htg -0.2 8 67.2 95.0 0.0 0.2 0.1 8 75.5 59.1 67.3 55.0 51.6 65.8 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 4 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 36 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.2 Total Opt Vent 0.0 0.0 0.0 0 -0.2 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 4 0 0 0.00 -2.03 0.00 0.00 0 Supply Air Leakage 80 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 0 0 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 8 8 8 0 0 0 0 0 8 8 8 0 0 0 0 0 0 28 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 12:05 PM on 12/02/2016 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 17 of 17 9762ROWHOUSE11.TRC 07/31/17