HomeMy WebLinkAboutD17-0012_A-720.1_1512591356.pdfINTERIOR PARTITION TYPES STRUCTURE A 7/8" HAT CHANNEL B 1 5/8" METAL STUD C 2 1/2" METAL STUD D 3 5/8" METAL STUD E 4" METAL STUD F 6" METAL STUD G 3 5/8" DOUBLE METAL STUD J 2 1/2" C-H METAL STUD K 4" C-H METAL STUD L 6" C-H METAL STUD M 2x4 WOOD STUD N 2x6 WOOD STUD P 4" CMU Q 6" CMU R 8" CMU S 12" CMU Z 1 1/2" "Z" FURRING CHANNEL D1sX EXAMPLE D = 3 5/8" METAL STUD 1 = 1 HOUR FIRE RESISTANCE RATING s = SOUND PARTITION FIRE RESISTANCE RATING* 0 NON-RATED 1 1 HOUR 2 2 HOUR 3 3 HOUR 4 4 HOUR SUB-TYPE a 6" ABOVE CEILING b UNDERSIDE OF STRUCTURE c UNDER SIDE OF CEILING f FURRING l LEAD LINED k SECURITY MESH p PARTIAL HEIGHT s SOUND PARTITION t THERMAL INSULATION v SOUND PARTITION WITH (2) LAYERS GYPSUM BOARD EACH SIDE w SOUND PARTITION WITH (2) LAYERS GYPSUM BOARD ONE SIDE (1) LAYER OTHER SIDE z TILE BACKER BOARD SMOKE RATED* X SMOKE PARTITION, SMOKE BARRIER OR WALL RESISTING THE PASSAGE OF SMOKE STRUCTURE FIRE RESISTANCE RATING SUB-TYPE SMOKE RATED * SEE RATED PARTITION NOTE 2 GENERAL CONSTRUCTION AND LAYOUT NOTES 1. THE INTERIOR FRAMING SUBCONTRACTOR SHALL PROVIDE A DELEGATED ENGINEERED STUD DESIGN FOR ALL NON-STRUCTURAL METAL FRAMING FOR WALLS AND CEILINGS. SUBMIT FRAMING SHOP DRAWINGS WITH DETAILS, PRODUCT SELECTIONS, AND ENGINEERING CALCULATIONS STAMPED BY A LICENSED ENGINEER IN THE PROJECT JURISDICTION. ENGINEERING SHALL INCLUDE PROVISIONS FOR ELEMENTS ATTACHED TO/SUPPORTED BY THE FRAMING. FASTENER DESIGN AND SELECTION IS ALSO REQUIRED. SUBMIT ICC ES EVALUATION REPORTS FOR EACH FASTENER. USE OF DIMPLED OR PERFORMANCE ENHANCED SHAPED STUDS IS ACCEPTABLE. UNLESS OTHERWISE INDICATED DESIGN FOR A MAXIMUM DEFLECTION OF L/240 AT 5 PSF. AT PARTITIONS TO RECEIVE CERAMIC TILE DESIGN FOR A MAXIMUM DEFLECTION OF L/360 AT 5 PSF. REGARDLESS OF DESIGN, PROVIDE 20 GA STUD AT A MINIMUM. 2. ALL INTERIOR PARTITIONS ARE DIMENSIONED TO FINISHED FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE. 3. ALL STUDS SHALL BE FULL HEIGHT TO UNDERSIDE OF STRUCTURE UNLESS INDICATED OTHERWISE BY PARTITION TYPE. 4. BOTTOM OF GYPSUM BOARD SHALL BE 1/4” TO 3/8” ABOVE FINISH FLOOR UNLESS OTHERWISE INDICATED. 5. OFFSET STUDS AS NECESSARY TO ALIGN OUTSIDE FACES OF GYPSUM BOARD AT ADJACENT WALL TYPES WITH VARYING LAYERS OF GYPSUM BOARD. 6. PROVIDE DEEP LEG TRACKS (3" FLANGE) AT HEAD OF PARTITIONS AT ALL NON-LOAD BEARING PARTITIONS FOR EACH CONDITION THAT ALLOW FOR 1" OF UPWARD MOVEMENT AND 1" OF DOWNWARD DYNAMIC MOVEMENT CAPABILITIES. 7. AT SLAB-ON-GRADE CONDITIONS PROVIDE DYNAMIC MOVEMENT REQUIREMENTS CALLED FOR IN THE GEOTECHNICAL INVESTIGATION (SOILS REPORT). IF NO GEOTECHNICAL INVESTIGATION EXISTS CONTACT THE ARCHITECT FOR DEFLECTION CRITERIA. 8. ALL PARTITION TYPES MARKED BY A "t" SUFFIX (IE. D0t) SHALL BE INSTALLED WITH FULL HEIGHT AND WIDTH CONTINUOUS THERMAL INSULATION AND, IF INDICATED, CONTINUOUS VAPOR RETARDER. 9. PROVIDE GYPSUM BOARD CONTROL JOINTS PER ASTM C 840 UNLESS OTHERWISE INDICATED ON DRAWINGS. 10. PROVIDE FIRE BLOCKING AND DRAFT STOPS PER CODE. 11. AT LOCATIONS ADJACENT TO GLASS SYSTEMS, GC TO VERIFY IN FIELD AND PROVIDE FASTENERS SUCH THAT THE INSTALLATION OF METAL FRAMING DOES NOT ADVERSELY IMPACT THE GLASS SYSTEM. RATED PARTITION NOTES 1. FIRE RATED ASSEMBLY CRITERIA TAKE PRECEDENT OVER ANY OTHER CONSTRUCTION CRITERIA. 2. REFERENCE LIFE SAFETY DRAWINGS FOR LOCATIONS OF FIREWALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE PARTITIONS, SMOKE BARRIERS, AND WALLS RESISTING THE PASSAGE OF SMOKE. COMPLY WITH IBC AND ANY OTHER APPLICABLE CODES FOR CONSTRUCTION REQUIREMENTS FOR EACH RATED PARTITION TYPE. 3. REFERENCE SPECIFICATION SECTION 07 8413 –‘PENETRATION FIRESTOP’ FOR TREATMENT OF ANY PENETRATIONS THROUGH A FIRE RATED PARTITION. NEEDS TO MEET UL LISTED TEST REQUIREMENT. 4. REFERENCE SPECIFICATION SECTION 07 8443 –‘JOINT FIRESTOP’ FOR TREATMENT OF TOP AND BOTTOM OF WALL JOINTS AND JOINTS TO ABUTTING CONSTRUCTION. NEEDS TO MEET UL LISTED TEST REQUIREMENT. 5. PROVIDE AND SUBMIT FOR APPROVAL U.L. RATED HEAD OF WALL ASSEMBLIES FOR EACH RATED PARTITION CONDITION THAT ALLOWS FOR THE DYNAMIC MOVEMENT INDICATED. IF ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ), OBTAIN ENGINEERING JUDGEMENTS FOR JOB SPECIFIC CONDITIONS NOT ADDRESSED BY TESTED ASSEMBLIES. 6. PROVIDE FIRE-RATED ACCESS DOORS AND FRAMES TO REACH DAMPERS OR CONTROL VALVES IN RATED PARTITIONS OR CEILING AS REQUIRED TO MAINTAIN RATING. PROVIDE NONRATED ACCESS DOORS AT NON RATED CONSTRUCTION. 7. WHERE DEVICES ARE RECESSED IN A FIRE RATED PARTITION PROVIDE: A.) DEVICE RATED FOR INSTALLATION IN RATED PARTITIONS, OR B.) CONSTRUCTION SUCH THAT FIRE RATING IS MAINTAINED BEHIND RECESSED DEVICE. 8. WHERE STRUCTURAL ITEMS SUCH AS HANGERS FOR STAIRS ARE EMBEDDED IN A RATED PARTITION CONSTRUCTION SHALL BE SUCH THAT FIRE RATING IS MAINTAINED BEHIND EMBEDDED ITEM. 9. MARKING AND IDENTIFICATION: FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE LABELED PER CODE. 10. PROVIDE SMOKE PARTITIONS TO LIMIT THE TRANSFER OF SMOKE. FILL JOINTS AND THE SPACE AROUND PENETRATING ITEMS SUCH AS DUCTS, PIPES, CONDUITS, AND SIMILAR BUILDING SERVICE EQUIPMENT WITH AN APPROVED MATERIAL TO LIMIT THE PASSAGE OF SMOKE. 11. SEE A-720.1 FOR TYPICAL FRAMING DETAILS. SOUND PARTITION NOTES 1. ALL PARTITION TYPES MARKED BY AN "s" SUFFIX (IE. D1s) SHALL BE INSTALLED AS A SOUND PARTITION INCLUDING: FULL HEIGHT AND WIDTH SOUND ATTENUATION BLANKETS (SAB), ACOUSTICAL JOINT SEALANT AT TOPS AND BOTTOMS OF ALL WALLS AND PENETRATIONS, DRYWALL TO BE FROM FLOOR TO DECK BOTH SIDES. 2. PROVIDE ELECTRICAL OUTLET BARRIER PADS IN SOUND PARTITIONS. 3. STAGGER DEVICES THAT PENETRATE OPPOSING WALL SURFACES IN ADJACENT STUD CAVITIES. RATED ASSEMBLY INFORMATION TOP OF WALL ASSEMBLY: • STANDARD INTERIOR NON-BEARING WALL ASSEMBLY: UL HW-D-0495 OR EQUAL • SHAFTWALL FLAT CONCRETE: UL HW-D-0496 • SHAFTWALL PARALLEL TO BEAM: UL HW-D-0497 • SHAFTWALL PAN DECK: UL HW-D-0504 • SHAFTWALL PROTECTED ROOF DECK: UL HW-D-0559 WALL ASSEMBLY: • STANDARD INTERIOR NON-BEARING WALL ASSEMBLY : UL U419 OR UL U423 • SHAFTWALL ASSEMBLY: UL U415 SILL TRACK OF WALL ASSEMBLY: • PROVIDE UL LISTED ASSEMBLY COMPLIANT WITH THE UL WALL ASSEMBLY AND THAT MATCHES FIRE RESISTIVITY OF THE WALL. DOOR / FRAME MATERIAL: AL/G - ALUMINUM GLASS HM - HOLLOW METAL WD - WOOD PT - PAINTED STAIN - STAINED MFR - MANUFACTURER DOOR FINISH: PL# - PLASTIC LAMINATE ST - STAINED, SEE BELOW CA - CLEAR ANODIZED PT - PAINTED KF - KYNAR FINISH GL - GLASS STAIN FINISH CODES ST0 = MATCH EXISTING ADJACENT FINISH WITHIN THE SUITE (COMMENT: MSA AREA, MISC.) ST1 = TO MATCH VT INDUSTRIES 'RAVINE RA07' (COMMENT: ADMIN DOORS EXCEPT NORTH ENTRY DOOR) ST2 = TO MATCH MARSHFIELD 'NUTMEG' (COMMENT: CORRIDOR DOORS, BLDG STD) DOOR NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS. 2. REFER TO SPECIFICATIONS FOR HARDWARE TYPES AND SCHEDULE. 3. ALL FIRE RATED DOORS SHALL HAVE UNDERWRITERS LABEL ON DOOR AND FRAME. 4. WHERE EXISTING DOORS TO REMAIN, TOUCH UP SCUFFING TO MAKE DOOR FINISH LIKE-NEW. 5. AT EXISTING DOORS IN SCOPE: WHERE SCUFFED,PATCH AND REFINISH TO LIKE-NEW CONDITION. IN AREA C, REFINISH EXISTING DAMAGED DOORS AND DOOR FRAMES. DOOR AND HARDWARE SCHEDULE - ABBREVIATIONS LEGEND/NOTES FRAME NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS PRIOR TO ORDERING OR FABRICATING ANY FRAMES. 2. ALL ELEVATIONS ARE DRAWN FACING THE EXTERIOR OF THE WINDOW FRAME. 3. STOREFRONT FABRICATOR TO PROVIDE REINFORCING AS REQUIRED 4. ALL DIMENSIONS ARE TO MASONRY OR ROUGH OPENING UNLESS NOTED OTHERWISE, PROVIDE PROPER SHIM CLEARANCE AS REQUIRED. 5. AT EXISTING FRAMES IN SCOPE: WHERE SCUFFED, PATCH AND REFINISH TO LIKE-NEW CONDITION GLAZING TYPES S = PROVIDE TEMPERED GLASS IN NON-RATED DOORS WHERE INDICATED. F = PROVIDE FIRE- PROTECTION-RATED GLASS MEETING OR EXCEEDING THE RATING OF THE DOOR ASSEMBLY WHERE INDICATED SEE SPECIFICATION FOR ACCEPTABLE GLASS TYPES. D0b 4 7/8"5/8" 3 5/8" 5/8"SINGLE OR DOUBLE DOOR FRAME HM1RE: SCHEDULE 2"2" RE: SCHED. 2" / C1 A-720.1 /C2A-720.1 SINGLE FLUSH F1 RE: SCHEDULERE: SCHED. SINGLE NARROW LITE (TEMPERED OR FIRE RATED GLASS) N1RE: SCHEDULERE SCHED. 3' - 4" 8"8"8" EXTERIOR BUILDING SYSTEMS NAMING SYSTEM TYPES PWS = PARAPET WALL SYSTEM RS = ROOF SYSTEM SS = SOFFIT SYSTEM CS = CEILING SYSTEM WS = WALL SYSTEM GS = GLAZING SYSTEM FS = FLOOR SYSTEM FWS = FOUNDATION WALL SYSTEM EXTERIOR BUILDING SYSTEMS 1. EXTERIOR BUILDING SYSTEMS SHEETS SHOW SYSTEM COMPONENTS. REFER TO SECTION AND DETAILS FOR RELATIONSHIPS BETWEEN BUILDING SYSTEMS FINISH TYPES EPDM = EPDM TPO = TPO PVC = PVC STO = STONE WD = WOOD MET = METAL MAS = MAS STU = STUCCO CMU = CMU WW = WINDOW WALL SF = STOREFRONT CW = CURTAIN WALL DP = DAMP PROOFING WP = WATER PROOFING EXAMPLE SYSTEM TYPE FINISH TYPE # - SYSTEM TAG PWS-MET2A TYPE RE: PARTITION SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 08 1416 - FLUSH WOOD DOOR 07 9200 - JOINT SEALANT 05 4000 - COLD-FORMED METAL FRAMING UNO 6" TYP. TYPE RE: PARTITION SECTION 09 2900 - GYPSUM BOARD 08 1416 - FLUSH WOOD DOOR 08 1113 - INTERIOR HOLLOW-METAL FRAME 05 4000 - COLD-FORMED METAL FRAMING 07 9200 - JOINT SEALANT WS_STUCCO1A BASIS-OF-DESIGN: MODIFIED DOW THERMAX X-ARMOR WALLSYSTEM WITH LIQUIDARMOR FLASHING AND SEALANT ON THERMAX XARMOR INSULATION. 09 2400 - EXTERIOR PLASTERWORK TO MATCH EXISTING 09 2900 - EXTERIOR GYPSUM BOARD SECTION 07 4265 - 4 MIL FOIL-FACED POLYISOCYANURATE FOAM-PLASTIC BOARD 10 1/4" WS_STUCCO2A 09 2400 - EXTERIOR PLASTERWORK TO MATCH EXISTING 5 7/8" 09 2900 - EXTERIOR GYPSUM BOARD 1" 5" 5/8" 2" 5/8" 1" 5/8"3 5/8" 5/8"1" 07 2100 - MINERAL-WOOL BLANKET 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, 1 2 3 4 5 6 A B C D E 1 2 3 4 5 6 A B C D E Sheet Title: Consultant Revision Date No. Sheet Information Project Information Original Issuance Date 9/28/2017 5:29:30 PM15924.00 A-720.1 2017 EAST WING ADDITION 180 S. Frontage Road West, Vail, CO 81657DOOR SCHEDULE, PARTITION TYPES, WALL SYSTEMS, AND DETAILS 09/28/17DP1 VAIL HEALTH DOOR SCHEDULE ROOM LEAF FRAME Hardware Set Fire Rating Wall Width Remarks REVNAME Door Type Door Material Finish Width Height Thickness Door Glass Type Frame Type Frame Material Frame Finish LEVEL 2_CENTRAL 204 CORRIDOR F1 3' - 0" 7' - 0" 1 3/4" HM1 4 7/8" 274 (E) MECHANICAL F1 WD 2' - 8" 6' - 8" - HM1 HM PT 45 PARTITION TYPES SCHEDULE PARTITION TYPE USE DESCRIPTION PARTITION WIDTH STRUCTURE CONSTRUCTION DESCRIPTION TOP OF WALL TO FIRE RATING DESIGN NUMBER (FIRE) D0b PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A 1/4" = 1'-0" FRAME TYPES 1/4" = 1'-0" DOOR TYPES 3" = 1'-0"C1 HM INTERIOR DOOR FRAME HEAD 3" = 1'-0"C2 HM INTERIOR DOOR FRAME JAMB GC TO VERIFY ACTUAL DIMENSION ON SITE WD ST2 ST2 1 3/4" - HM PT 44 45 12/06/17