HomeMy WebLinkAboutD17-0012_LS100.1_1512591354.pdfEXISTING FIRE RESISTIVE REQUIREMENTS TO BE MAINTAINED: STRUCTURAL FRAME BEAMS COLUMNS EXTERIOR BEARING WALLS INTERIOR BEARING WALLS EXTERIOR NONBEARING WALLS FLOOR CONSTRUCTION ROOF CONSTRUCTION & CANOPY SHAFT & VERTICAL EXIT ENCLOSURES EXTERIOR OPENINGS EDGE OF SLAB IBC RATING TEST NFPA RATING CONSTRUCTION (TYPE I B) (II-222) UL 263 UL UL 790 UL NOTE : REFER TO PARTITION TYPES SCHEDULE ON A-720-1 FOR UL ASSEMBLIES AT ADDITIONAL INTERIOR PARTITIONS AND WALL RATINGS AND SPECIFICATION SECTION 078413 PENETRATION FIRESTOPPING FOR USE OF UL ASSEMBLIES AT THROUGH-PENETRATION FIRESTOP CONDITIONS. REMARKS 2 HR 2 HR 2 HR 2 HR 0 HR 2 HR 1 HR PER 8.6.5 2 HR 2 HR 2 HR 2 HR PER 602 2 HR 1 HR PER 713.4 PER T705.8 NOTE: WORK TIMES LIMITED BY "VAIL VILLAGE AND LIONSHEAD VILLAGE CONSTRUCTION INFORMATION HANDOUT," CURRENT REVISION, IN ADDITION TO OWNER REQUIREMENTS. APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2009 ANSI A117.1 ACCESSIBILTY CODE 2012 NFPA 101 NFPA 241, CURRENT EDITION CODES TO BE GOVERNED BY LOCAL AMENDMENTS, STATE, AND FEDERAL REGULATORY ENTITIES. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, 1 2 3 4 5 6 A B C D E 1 2 3 4 5 6 A B C D E Sheet Title: Consultant Revision Date Sheet Information Project Information Original Issuance 9/28/2017 5:30:22 PM15924.00 LS100 2017 EAST WING ADDITION 180 S. Frontage Road West, Vail, CO 81657CODE ANALYSIS 09/28/17DP1 VAIL HEALTH GENERAL CODE SUMMARY BUILDING DESCRIPTION: THE VAIL VALLEY MEDICAL CENTER (VVMC) IS AN EXISTING HEALTH CARE FACILITY WITH CONSTRUCTION DATES SPANNING BETWEEN 1969 AND 2016 INCLUDING ADDITIONS AND RENOVATIONS. THE EXISTING VVMC IS 4 STORIES WITH A LOWER/BASEMENT LEVEL AND HAS A CONSTRUCTION TYPE DECLARATION OF I-B PER IBC AND II (222) PER NFPA 101. BUILDING IS SPRINKLER PROTECTED THROUGHOUT, EXCEPT FOR LEVEL 2 OF THE EAST OFFICE BUILDING WHICH WILL BE REPLACED WITH THE PROPOSED EAST WING ADDITION. BUILDING HAS AN EXISTING FIRE ALARM AND DETECTION SYSTEM. SCOPE OF WORK: FIRST FLOOR EMERGENCY DEPARTMENT REMODEL THIS PHASE OF THE PROJECT (DP1) INCLUDES THE DEMOLITION OF THE EXISTING ADMINISTRATION BUILDING, NFPA 241 PROVISIONS, A SINGLE WALL WITH A DOOR, AND AN EGRESS PATHWAY OUT OF AN EXISTING MECHANICAL SPACE. THE PROVISIONS FOR DEMOLITION INCLUDE A WALL SEPARATING THE CONSTRUCTION ZONE FROM THE HOSPITAL COMPLIANT WITH NFPA 241. THE WALL, DOOR AND THE MECHANICAL ROOM EGRESS PATH ARE BEING INSTALLED TODAY TO SUPPORT LIFE SAFETY REQUIREMENTS FOR FUTURE WORK. APPLICABLE CODES-CITY OF VAIL: TOWN OF VAIL AMENDMENTS TO INTERNATIONAL CODES AND VF&ES GUIDELINES 2015 INTERNATIONAL BUILDING, FIRE, MECHANICAL, AND PLUMBING CODES 2017 NATIONAL ELECTRICAL CODE PER STATE 2009 ANSI A117.1, ACCESSIBILITY REQUIREMENTS AS REFERENCED IN 2015 IBC FOR A COMPLETE LIST OF STANDARDS REFERENCED IN IBC, PLEASE REFER TO CHAPTER 35 OF THE 2015 IBC, EXCEPT THAT ALL NFPA CODES AND STANDARDS SHALL BE THOSE NOTED IN 2015 IFC CHAPTER 80. THE FOLLOWING IS NOT A COMPLETE LIST OF ALL NFPA STANDARDS REFERENCED IN IFC CHAPTER 80-PLEASE REFER TO THIS CHAPTER FOR THE COMPLETE LIST. PLEASE NOTE THAT THE COLORADO DEPARTMENT OF PUBLIC SAFETY HAS ADOPTED THE 2012 NFPA 101 WITH REFERENCE TO PREVIOUS EDITIONS OF NFPA CODES AND STANDARDS. THE MOST RESTRICTIVE PROVISIONS OF THE STANDARDS WITH DIFFERENT EDITIONS WILL GOVERN. TITLE OF PUBLICATION: NFPA 10 PORTABLE FIRE EXTINGUISHER – 2013 NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS – 2013 NFPA 72 NATIONAL FIRE ALARM CODE – 2013 THE COLORADO DIVISION OF FIRE PREVENTION AND CONTROL (DFPC) HAS ADOPTED THE FOLLOWING: 2012 NFPA 101 LIFE SAFETY CODE AND THE REFERENCED STANDARDS (NFPA 13, 14, 72, ETC.) FACILITIES GUIDELINES INSTITUTE, INC. (FGI) - 2010 GUIDELINES. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOTION OPERATIONS. MEANS OF EGRESS - CORRIDOR AND SUITE SEPARATION: TRAVEL DISTANCE:TRAVEL DISTANCE WITHIN THE CURRENT PATIENT CARE NON-SLEEPING SUITE TO AN EXIT ACCESS DOOR FROM THE SUITE DOES NOT EXCEED 100 FT, NFPA 101 SECTION 18.2.5.7.3.4 AND IBC SECTION 407.4.4.3. CORRIDOR CONSTRUCTION: HEALTH CARE CORRIDOR WALLS ARE DESIGNED TO LIMIT THE TRANSFER OF SMOKE AND DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE AND BE SELF LATCHING AND BE PROVIDED WITH POSITIVE LATCHING HARDWARE, 2012 NFPA 101 SECTIONS 18.3.6.3.5, 18.3.6.2 AND 18.3.6.3.1. CORRIDORS WALLS ARE CONSIDERED NON-RATED SMOKE PARTITIONS. CORRIDOR WALLS IN THE ED AREA ARE EXISTING EXCEPT FOR THE REQUIRED UPGRADES TO CONSIDER THESE WALLS AS SMOKE PARTITIONS. CORRIDOR WIDTH: NFPA 101 SECTION 18.2.3.4 AND IBC 1020.2. THIS CORRIDOR IS 8 FT WIDE EXCEPT FOR A SMALL SECTION WHERE THE EXISTING WIDTH IS APPROXIMATELY 7 FT WIDE AND HAS BEEN APPROVED BY THE DFPC. WE WOULD ALSO LIKE TO REQUEST THE SAME CONSIDERATION FROM THE TOWN OF VAIL AHJ AS THIS IS AN EXISTING CONDITION AND THE LENGTH OF THE CORRIDOR WITH 7 FT WIDTH IS LIMITED. SUITE SEPARATION EACH SUITE THROUGHOUT THE BUILDING IS SEPARATED FROM THE REMAINDER OF THE FLOOR/SPACES BY WALLS THAT RESIST PASSAGE OF SMOKE PER NFPA 101 SECTION 18.3.6.3.5 AND 18.2.5.7.1.2 AND SMOKE PARTITIONS PER IBC 407.4.4.2. EXISTING WALLS WILL BE UPGRADED TO SMOKE PARTITION AS NEEDED. SUITE AREAS AREA OF NON-PATIENT CARE SUITES IS LIMITED TO 10,000 SF PER NFPA 101 SECTION 18.2.5.7.3.4 AND 12,500 SF PER IBC SECTION 407.4.4.6. SUITE EGRESS NFPA 101 SECTION 18.2.5.7.3.2 AND IBC 407.4.4.6.2. 12/06/17