HomeMy WebLinkAboutA16-0048_A10.1_1478896432.pdfA4.1 A4.1
1 2
A4.2
1
A4.2
2
1
A5.1
1 3 4 5 6 7 8 9 10
2
A
B
C
D
E
F
G
H
I
J
2
A5.2
2
A5.1
BEDROOM #4
006
ELEVATOR
009
CLOSET #4
008 LAUNDRY
007
BEDROOM #5
011
MECHANICAL
012
GAME ROOM
016
POWDER ROOM
017
MECHANICAL
020
BATHROOM #4
004
CLOSET
005
B.O. GWB @ 8' - 11 7/8" A.F.F.
1
A5.3
B.O. GWB @ 8' - 2 1/4" A.F.F.
B.O. GWB @ 8' - 11 7/8" A.F.F.
B.O. GWB @ 8' - 2 1/4" A.F.F.
B.O. GWB @ 9' - 2" A.F.F.
2
A5.3
B.O. GWB @ 8' - 2 1/4" A.F.F.
4
A5.3
B.O. GWB @ 9' - 2" A.F.F.
4
A5.2
5
A5.2
3
A5.3
1
A5.2
B.O. GWB @ 9' - 6 5/8" A.F.F.
B.O. GWB @ 9' - 2" A.F.F.
3
A5.2
2
A5.4
1
A5.4
2' - 0" TYP.
A A
A
A
A2 A2
A2
A2
A
A2
A2
A
A2
A A
A2
A
A2
TELEPHONE/
DATA TV GFI
L
A
A
A
A2
A2
J-BOX
J-BOX
A
A
A
A3
A
A3 A3
FAN FAN
D4 D4 D4
TELEPHONE/
DATA
TV L
A4 A4
A4 A4
PROVIDE POWER AS
REQ'D. PER MECHANICAL
EQUIP. RE: MECH.
A
A
GFI
GFI GFI
J
J
A A
A A
A
A3
A
A
A4
A2
A2
TELEPHONE/
DATA
TV D5
D5
PROVIDE POWER AS
REQ'D. PER MECHANICAL
EQUIP. RE: MECH.
Q
Q
Q
Q
Q
Q
TO UPPER RUN
STEP LIGHT
F
FAN
TELEPHONE/
DATA
Q Q
WP
TELEPHONE/
DATA
2' - 0"
A2 A2
B.O. GWB @ 7' - 10 3/8" A.F.F.
H
H
A4 A4
B.O. GWB @ 8' - 2 1/4" A.F.F. B.O. GWB @ 8' - 2 1/4" A.F.F.
A
A2 H
3
A5.4
CLOSET #5
021
H
B.O. GWB @ 9' - 6 5/8" A.F.F.
A3
B.O. GWB @ 8' - 2 1/4" A.F.F.
A4
A4
H
H H
FAN
220
GFI
BATH #5
015
A4 A4
3
A5.1
FAN
A A
D4
D7 D7 GFI
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
2/3/2015 3:37:51 PM
A10.1
LOWER
LEVEL RCP
AG
HB
FLEEGER
RESIDENCE
02/03/2015
2950
BOOTH
CREEK DR, VAIL
VILLAGE
FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1/4" = 1'-0"
1
LOWER LEVEL REFLECTED CEILING
PLAN
No. Revision Date
Revision
Description
Fire Alarm Control Panel
120vac Gentex Combination Smoke Detectors
Gentex 120vac CO Detector
Low Frequency Horn Only
Exterior Horn Strobe
KP System Keypad
Scope of Work:
** Install New Fire Security Panel
** Install new Combination 120vac Gentex Smoke Detectors
** Electrician to provide a dedicated 120vac 20amp circuit to all
smoke detector locations and Separate 120vac 20amp Circuit to the FCP
Location.
** Install New Gentex 120vac CO Detector
** Install new Low Frequency Horns on Each Level and in Each Bedroom
** Monitor Fire Sprinkler System
** Install Exterior Horn / Strobe for Fire Sprinkler Water FLow Indication
** Each Detection Device to have an 18/6 FPL Home Run to the Fire
Control Panel
** One 14/4 FPL Circuit to be run to each LF Horn per Floor
Gentex 120vac Combination Smoke/CO
Gentex 120Vac Combination Smoke/CO
Gentex 120vac J-BOX Combination Smoke/CO
Vail Fire & Emergency Services
09/12/16