HomeMy WebLinkAboutA16-0048_A10.2_1478896434.pdfA4.1 A4.1
1 2
A4.2
1
A4.2
2
1
A5.1
1 3 4 5 6 7 8 9 10
2
A
B
C
D
E
F
G
H
I
J
2
A5.2
M
C
C
C
C
C
E
E
M
3' - 8 7/8" 3' - 8 7/8" 3' - 8 7/8" 4' - 0" 3' - 9" 3' - 9 1/4"
2
A5.1
1
A5.3
2
A5.3
4
A5.3
GARAGE
101
MUD ROOM
102
CLOSET
103
POWDER ROOM
104
ELEVATOR
105
PANTRY
107
KITCHEN
106 FAMILY ROOM
108
DINING
109
STAIR
110
ENTRY
112
LIVING ROOM
111
BAR
113
4
A5.2
B.O. GWB @ 8' - 3" A.F.F.
B.O. GWB @ 9' - 6 7/8" A.F.F.
B.O. GWB @ 9' - 6 7/8" A.F.F.
B.O. GWB @ 9' - 6 7/8" A.F.F.
B.O. GWB @ 9' - 6 7/8" A.F.F.
1' - 11 3/8" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 6"
4' - 0" 4' - 0" 4' - 0" 4' - 0"
5
A5.2
3
A5.3
1
A5.2
3
A5.2
2
A5.4
1
A5.4
Q
Q Q Q
Q
Q
Q
Q Q
Q Q
M
M M
M
M
MM
M
M1
M1
Q
Q
Q Q
Q
Q
DOWNSPOUT FROM DECK
GUTTER ABOVE
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
BENCH CUBBIES
A A
A
A
A
A FAN
A2
A
D6
D6 GFI
GFI
GFI
ABOVE COUNTER
BUILT IN MICROWAVE
APPLIANCE
GARAGE
CABINETS
DW
DW
TRASH
ICE WINE
RECYCLING
PROVIDE POWER FOR HOOD AS REQ'D.
PROVIDE GAS, 220, AND 110
OUTLET FOR RANGE
A2 A2 A2
A
A
A
A
A
A
A
A
A
A A
A
A
GFI
TV TELEPHONE/
DATA
TELEPHONE/
DATA
TV
A
A A A
A
A
A2
A2
A2
A2 A2
A
A
P2
Q Q
Q
Q
Q
Q
Q
A2 A2
A
A
A
A
A2 A2
A A
A
A2
L1
B
B
B
B
B
B
P3
P3
Q Q
Q
Q
J-BOX
J-BOX
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
SEE UPPER LEVEL RCP
FOR LIGHTING
CALLOUTS AND
LAYOUTS
C
C
C
C
C
C
WP
Q WP
WP
WP WP
J-BOX
J-BOX
J-BOX J-BOX
J-BOX
C1 C1
C1
11" TYP.
C1
C1
C1 C1 C1
C1
C1 C1
A
A
A
A
P2 P2
A A
A A
A A A
A4
A4 A4
A4
4' - 6"
3' - 3 15/16" 13' - 2 13/16" 10' - 3 1/2" 4' - 6"
9' - 3 7/8" CL OF STEEL BEAM
3 5/8" CL OF STEEL BEAM
19' - 5 7/16"
10' - 6 3/16"
4' - 4" 19' - 0"
1 5/8"
3' - 11 5/8"
2 3/4"
8' - 3 7/16"
6 3/8" CENTER OF STRUT OFF OF GRID LINE
8' - 6"
6 1/4" 19' - 6"
1/2"
7' - 3" 6' - 4 1/16"
2' - 1 1/16"
2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 1' - 6" 2' - 6"
F
4 7/8" 10' - 7 5/8"
9 3/8"
4' - 0" 4' - 0" 1' - 5 3/4" 7" 2' - 4"
1 7/8"
3 1/4" 4' - 1 1/2"
H H H
H H H
B.O. GWB @ 9' - 0"
3
A5.4
3' - 4 1/2" 3' - 10 1/2"
BATHROOM
114
B
B
2" / 12"
FAN
B2 B2
D8
D8
B
3
A5.1
G
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
2/3/2015 3:38:05 PM
A10.2
MAIN LEVEL
RCP
AG
HB
FLEEGER
RESIDENCE
02/03/2015
2950
BOOTH
CREEK DR, VAIL
VILLAGE
FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1/4" = 1'-0" 1
MAIN LEVEL REFLECTED CEILING PLAN
No. Revision Date
Revision
Description
KP
Gentex 120vac Combination Smoke/CO
Gentex 120vac CO Detector
Vail Fire & Emergency Services
09/12/16