HomeMy WebLinkAboutA16-0048_A10.3_1478896446.pdfA4.1 A4.1
1 2
A4.2
1
A4.2
2
1
A5.1
1 3 4 5 6 7 8 9 10
2
A
B
C
D
E
F
G
H
I
J
2
A5.2
2" / 12"
2
A5.1
MASTER
BEDROOM
201
MASTER
BATHROOM
202
W.C.
203
MASTER CLOSET
204
CLOSET #2
206
BEDROOM #2
207
ELEVATOR
205
BATHROOM #2
208
W.C.
209
BEDROOM #3
210
BATHROOM #3
212
CLOSET #3
211
GUEST MASTER
CLOSET
214
GUEST MASTER
BEDROOM
213
GUEST MASTER
BATHROOM
215
OFFICE
216
LINEN CLOSET
217
1
A5.3
2
A5.3
4
A5.3
4
A5.2
B.O. GWB @ 8' - 0" A.F.F.
B.O. GWB @ 9' - 4" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 9' - 4 1/8" A.F.F.
B.O. GWB @ 8' - 6" A.F.F. B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
5
A5.2
B.O. GWB @ -11' - 0 1/2" A.F.F.
B.O. GWB @ 10' - 8 1/4" A.F.F.
B.O. DECKING @ 12' - 1 1/8" A.F.F.
B.O. DECKING @ 11' - 6"
B.O. DECKING @ 16' - 3 3/4"
CURVED CEILING
CURVED CEILING
CURVED CEILING
3
A5.3
1
A5.2
3
A5.2
2
A5.4
1
A5.4
B.O. GWB @ 8' - 6" A.F.F.
STEAM SHOWER
218
B.O. GWB @ 8' - 6" A.F.F.
J-BOX
J-BOX
SEE MAIN LEVEL RCP FOR
LIGHTING CALLOUTS AND
LAYOUTS
B
B B B
B
B B
B B B
B
B
B
B B
B
B
B
B
B B B B
B B
B B
L
C
C
A2 A2 A2 A2
A2
A2 A2
TV TELEPHONE/
DATA
F
G G
A
A TV
TELEPHONE/
DATA
G
CURVED CEILING
TV
TELEPHONE/
DATA
B.O. GWB @ 8' - 6" A.F.F. 2" / 12"
FAN
FAN
FAN
FAN
FAN
FAN
FAN
J-BOX
B B
B
B
B B
B
B
B B
A
A A
A3
A3 GFI
GFI
B
B
B B
B
J-BOX GFI
D3 D3
D1 D1 D1
D2 D2
B B B2
B2
A A A3
A3 GFI
GFI
TELEPHONE/
DATA
TV
J-BOX
B
B B
B
B
G G G
G
G
SINGLE
HANGING
SINGLE
HANGING
DOUBLE HANGING
DOUBLE HANGING
HIGH SHELVES @ 7'
HIGH SHELVES @ 7'
GFI
GFI
A A A
A3 A3 A
D
D D
D
D D
L
J-BOX
J-BOX
A2
A2
A2
A2 B B B B
B
B B B
B
B B
B
REF.
TELEPHONE/
DATA
TV
TELEPHONE/
DATA
TELEPHONE/
DATA
TELEPHONE/
DATA
C1
C1 C1 C1 C1 C1
C1
B.O. GWB @ 7' - 10 5/8" A.F.F.
TELEPHONE/
DATA
Q
Q
Q
Q
Q
Q
B
A A3 A
C
C C C
C C
C
C
C
A A
4' - 0"
4' - 0"
4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 5 11/16" 3' - 5 11/16" 7 7/8"
6" 3 3/8"
2' - 2 5/8"1' - 6 3/8" 3' - 9" 3' - 9" 3' - 9" 3' - 9" 3' - 9" 3' - 9"
3 3/8"
6"
22.500¡
3
A5.4
4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0"
6"
3
A5.1
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
2/3/2015 3:38:11 PM
A10.3
UPPER
LEVEL RCP
AG
HB
FLEEGER
RESIDENCE
02/03/2015
2950
BOOTH
CREEK DR, VAIL
VILLAGE
FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1/4" = 1'-0"
1
UPPER LEVEL REFLECTED CEILING
PLAN
No. Revision Date
Revision
Description
Gentex 120vac Combination Smoke/CO
GAe2n tex 1 20vac CCombination Smoke /CO
Gentex 120vac
Combination Smoke/CO
Gentex 120vac Combination
Gentex 120vac Combination Smoke/CO
Gentex 120vac Smoke/CO
Smoke/CO
Vail Fire & Emergency Services
09/12/16