Loading...
HomeMy WebLinkAboutE2.1X.pdf I I 8'-0" 8'-0" 8'-0" / / / j 7/ \ ,I ,. // //O / i / / , , i , / , r� i ii . i / / / / iir. // , �i r // , , , REFLECTED CEIL. / ELEC. NOTES 0, 600626.-- 0 ,66,050000006,0600,00.00702000002.00,4000/ \ jElectr■cal Legendo 1 . Place outlets as required by the adopted -- N _ _ N IBC/IEC. Contractor to verify spacing with electricals _ J •I . Switched Outlet code. All wall outlets shal118 above floor +/-) unless / \ / -\ . A otherwise noted. Outlets above counters shall be 7111"4 C 3 9 Duplex Outletplaced horizontally in backsplash. I II -I � UEGER Ceiling Fan V Chandelier c 0 Nv.203556 Quad Outlet u.- % • e'er �,- n 2. Fixtures, switches and outlets shown are called Z� Monopoint Television Outlet } /El ' !y �1� out by general type unless a schedule is attached. waissomso ,,,, ,,,/ /;,,, , ,,, „ T, ,, , /,' „ _ _ _ (' O] W al ��; Recessed Can providep r' R E C \ ❑ // ELECTRICAL OUTLETS FOR TV BY AS REQD AV O\‘' to specifications. i BY OWNER TO BE PROVIDED BY N❑ Telephone Outlet / � � - �; C ROOM 4 ELECTRICIAN Recessed Can-Directional �� ��� �` �� ��� Single Switch 3. Actual ceiling/soffit heights may vary according %, ;�, u W N o 0o E to venting, structural and electrical requirements. 3'-6" i" m LO C0 0 ��, Waterproof Light g - / .� % pM0 O v 3-Way Switch % Y %/ o %/ lie 3 Verify final ceiling heights with Architect if different 6 / % • X00 0 ' Surface Mounted Fixture % O 4 4-Way Switch from those noted prior to construction. %A_ I 0 0 / 68 / m -01 Wall Sconce SD Dimmer Switch Ale 0 0 W O dl s 4. Light fixtures shall be located where a 1-2 © co Pendant Light Fixture Motion Detector Switch Framing = / ` (.) g � dimensioned or centered in spaces. shall take into account desired fixture location. Where = `?� p 4' 6" 4'-6" 4'-6" aA © Smoke Alarm T 1� " 42" `� N EXJ Existing Junction Box conflicts with framing occur, notify Architect BED 1 _� $\0 42gp qp T❑ Thermostat 0,, * ExistingFixturern / 0 EXLT - �I— ,;,, /, 04 , „, , 5. Recessed luminaires Installed in the budding — II, ;!%,i., / ;,�%i/,,'//r,%i% „%�/�!%"!�i�j; Fire Sprinkler ,- C� /, thermal envelope shall be sealed to limit air leakage 0 \ 3 - co ❑ Junction Box u_ ` ' % co ��v Cable Lighting �'ir N 4'-6" e " W i » !i S? 9 g between conditioned and unconditioned spaces. All 1v❑ 0El 4—s 5' o" 5-0 4-0 / / / : / V Exhaust Fan Under Counter Strip Light recessed luminaires shall be IC-rated and labeled as 1 0 I S _.1; --- -------- o meeting ASTM E 283 when tested at 1 .57 psf (75 Pa) „ I ,`: ,,�� / MDQ T/fio S MECHANICAL 07. Floor Outlet i Fluorescent fixture pressure differential with no more than 2.0 cfm (0.944 — — — `� / I / M \ / ,,/ ROOM/ Q Motion Sensor D D Track Lighting L/s) of air movement from the conditioned space to I LAUNDRY PI� ; the ceiling cavity. All recessed luminaires shall be - / '�; T A S r i All lighting, outlet and smoke alarm quantity and 1aaaaa-e-e-0 LED Strip Lighting .l I I sealed with a gasket or caulk between the housing I = ii _' '� LIGHT IN CLO ELow STAIRWAY N.l \l i .- 1� Wi CO of All fixtures noted as O.S.are to be supplied by owner. and the interior wall or ceiling covering. ' 11 i I (VV.) �I ' 42" ! LU 1 I 111 • 111 , - 4 . 111 o i'_ _ \ 111 1b ii142" 0 Ell. %I _ / 42" 47 `D _ W Iz p _ / G A RA�6 I \ U // P IhIS 4D \ M r ) %% Ce 0 LLI 5 0" / 'i1��10 12'-0"�I / ��' i \ /,//,0 Service Calculation \ illipy :/$/ ❑ .�, .�, OP .zio Lighting Demand Load line neutral _ I ' , / , \ .. j Z Ilk Square Footage 4500 13500 13500 I u 17r I I ,Ai Small Appliance 2 1500 3300 3000 BED 2 T IN 5 -= U P 5 -Q• o V1---717/11 J Laundry Circuit 2 1500 3000 3000 ❑ 1 O R @\6.6" - CH I `� , — I '% Z LL First 3000w 10046 Total Load 19500 3000 19500 L3000 — B.= — \^ _, / W O Next 3001 to 120000 la 3596 5775 5775 E `�-�J \ t !I• ii 0 \Total Lighting Demd B775 8775 ge nI 12-0 ` . ' 1 v I W J A/C and Heat Demand %— jilrILMI 0 - Q 1 \N - 1. ANIEN:iE Air Conditioning Load 240V Qua KVA Total I Shp 2.5 ton 1 4.5 5AR 1 LLI i > /s / Air Conditioning Total 5 ! _ U Electric Heat Load 240V 0 0 0 '�� - �� FLOURESIENT STRIP LIGHT MOUNTED ON LU 0 O ® DOORBELL I I CEILING BOVE SUSPENDED GARAGE DOOR YYY VVV Q 1 I 1 TRACK(V1.F.) Electric Heat Total 0 Air Conditioning Larger Total Heat vs. Air Conditioning=> 4500 I — ` o III \ ill MI aJomit electric heat �- (gt [7. I 1►_ 11 II■■III■IIZ O Appliance Fastened in Place Voltage Qua watts Line Neutral ��� % j111,111,1111 1 1 Q Dishwasher 120 1 1600 1600 1600 , I- 0111 < Z Disposal 120 1 1200 1200 1200 Refrigerator 120 1 1500 1500 1500 r� ; \ ir IIIIM - Under Cabinet Rehig 120 1 1000 1000 1000 % - Whirlpool Tub 120 1 1900 1900 1900 Qp - j CL ap Hot Tub 240 1 5000 5000 0 — — — �' I % AI 1 1 Em J M Steamer 240 0 5000 0 0 % 6 0 \ III M MIME1 Q Q I . Insta Hot 120 0 600 0 0 - - ' 1 o .M Microwave 120 1 800 800 800 j I I II %/,/!,4;/' /r% „5 //, — convector 120 0 1200 0 0 0 cn I Z Fan blower 240 100 0 0 0 BED 3 I audio visual equipment 120 1 700 700 700 �— " MI \ / \ washer 120 1 1500 1500 1500 _ dryer 120 1 1500 1500 1500 ( 0 ,•� / & (A ' \ __..--- gas I —\ r ♦A O Boiler 120 1 500 500 500 \ *s STEP UGHTS RECESSED IN STONE VENNEER I \ `/� Steam Unit 240 0 6000 0 0 \ o TO LIGHT STAIRWAY Exhaust Fans 120 4 200 800 800I F r 6 fan coil unit 240 0 800 0 0 0 1 ISSUED FOR: DATE: humidifier 240 6 11300 0 0 / FLOOD LIGHT MOUNTED ON BACK SIDE OF FLOOD LIGHT MOUNTED ON BACK SIDE OF :/%'% � BEAM ABOVE OR ON SIDE OF JOIST FOR BEAM ABOVE OR ON SIDE OF JOIST FOR OWNER REVIEW 8-21-15 fan coil unit 240 0 500 0 0 ) Heat Tape 240 4 2000 8000 0 = I y , CONCEALED LIGHTING(Y.LF.) CONCEALED LIGHTING 0 ® I OWNER REVIEW 9-9-15 0 0 ,11i, i% I OWNER REVIEW 9-17-15 0 0 g:‘ ` of Total Appliance (75%for 4 or more) 26000 13000 19500 9750 \�,( ' CONCEPTUAL DRB 10-12-15 0- 0 EIec.Clothes Dryer (5Kw min) 1 5000 - U P - I II �L FINAL DRB 11-23-15 5 -6 111 1 u Demand Factor%(220-18) 100% 5000 3500 ,, m 1 "i�'% '' A FINAL DRB REVS 12-8-15 Electric Cooking Equipment MOTION SENSOR TO ACTIVATE EXTERIOR MOTION SENSOR TO ACTIVATE EXTERIOR I PRICING 1-7-16 Demand Factor Kw(220-19) 6.4 6400 4480 STEP LIGHTS GARAGE UGHTS (V.I.F.) (V.IE.) I PERMIT 2-22-16 Largest Motor * 25% volts, watts 240 4500 1125 0 I Total Demand line 45 300 I Total Demand Neutral 26505 L J Line Amperage Demand 189 Neutral Amperage 110 220-22 First 200 at 100% 110 Remainder at 7094 0 Neutral Amperage Demand 110 System Voltage H,L 240 120 /1I1 SHEET SCALE: 1/4"= 1'-0" DRAWN BY.: PK PROJECT: 738 SANDY LANE Service Sia 1 2717/1 6 ====.� 200 0 COPYRIGKRUEGERARCHIHT2015 TECTURE 8 DESIGN ' - - ' 1 MAIN LEVEL ELECTRICAL PLAN ELECT. PLANS ill E2.1 SCALE: 1/4" = 1'-0" E2 . 1