HomeMy WebLinkAboutLoad Calcs_54.pdf PAGE 1
RESIDENT ELECTRICAL LOAD SHEET
Keller- Motsinger
Pitkin Creek Unit 71
3971 Big horn Road
Vail, CO 81657
Address:
LIGHTING LOAD
ART:220-3(A)TOTAL SQUARE FOOTAGE OF HABITABLE LIVING 1235 @ 3WATTS PER SQFT= 3705 WATTS
ART:220-16(A)TWO SMALL APPLIANCE CIRCUITS @1500 WATTS 2 @ 1500 WATTS EACH= 3000 WATTS
ART:220-16(A)ADDITIONAL SMALL APPLIANCE CIRCUITS EACH 1 @ 1500 WATTS EACH= WATTS
ART:220-16(B)LAUNDRY CIRCUIT(WASHER) @ 1500 WATTS 1 @ 1500 WATTS EACH = 1500 WATTS
LIGHTING LOAD SUBTOTAL= 8205 WATTS
TABLE 220-11
FIRST 3000 WATTS OF LIGHTING 100% 3000 WATTS
REMAINDER FROM 3001 TO 120,000 WATTS 5205 @ 35% 1822 WATTS
REMSINDER OVER 120,000 @25%
APPLIANCE LOAD
ART:-17 DISPOSAL 1 X 600 WATTS= 600 WATTS
MICROWAVE 1 X 1500 WATTS= 1500 WATTS
COMPACTOR X 1200 WATTS= WATTS
DISHWASHER X 1200 WATTS= 1200 WATTS
OTHER X WATTS
OTHER X WATTS
APPLIANCE SUBTOAL= 3300 WATTS
(4 OR MORE APPLIANCES 75%)
ART:220-17 APPLIANCE SUBTOATL: WATTS X %= WATTS
ELECTRIC CLOTHES DRYER
PAGE 2
5000 WATTS OR NAME PLATE RATING( WHICHEVER IS GREATER) DRYER TOTAL= 5000 WATTS
WATER HEATER
ART-220-18 @ NAMEPLATE RATING: WATERHEATER LOAD= 5000 WATTS
HOUSEHOLD COOKING EQUIPMENT
TABLE 220-19 COOKING UNITS-INCLUDES RANGES,WALL MOUNTED OVENS,COUNTERTOP
UNITS,AND OTHER HOUSEHOLD COOKING UNITS.
NUMBER OF UNITS-
ONE UNIT USE 8000 WATTS
TWO UNITS USE WATTS
THREE UNITS USE WATTS
FOUR UNITS USE WATTS
FIVE UNITS USE WATTS
COOKING TOTAL= 8000 WATTS
SPACE HEATING/ AIR CONDITIONING
ART: 220-4(A)AIR CONDITIONER NAMEPLATE RATING @ 125% WATTS X 125% WATTS
OR
ART:220-21 WHICHEVER IS LARGER
ART: 220-15 ELECTRIC HEAT NAMEPLATE @ 100%
HEAT PUMP
ART: 220-4(A) LARGEST CONDENSING UNIT NAMEPLATE @125% WATTS X 125% WATTS
ART:440-33 A N D
ART:220-15 SUPPLEMENTARY HEAT( RESISTANCE) @ 100% WATTS X 100% WATTS
ADDITIONAL HVAC EQUIPMENT
Page 3
ART:220-15 CONDENSING UNITS OR A/C WATTS X 100% WATTS
SPACE HEATING/AIR CONDITIONING TOTAL=
OPTIONAL EQUIPMENT
ART:220-3(B)SWIMMING POOL AND OR/SPA 14300 WATTS X 100% WATTS
AET430-24 LARGEST MOTOR(S) NAMEPLATE(S) 7040 WATTS X 125% WATTS
LIGHTS AND OTHER MISC. EQUIPMENT: 5000 WATTS X 100% WATTS
POOL/SPA TOTAL= WATTS
TOTAL DEMAND ON SYSTEM
ART:220-10 SUM OF TOTAL: LIGHTING LOAD TOTAL= 4822 WATTS
APPLIANCE TOTAL = 3300 WATTS
DRYER TOTAL = 5000 WATTS
WATER HEATER = 5000 WATTS
COOKING TOTAL = WATTS
SPACE HEATER/AIR CONDITIONING TOTAL = WATTS
POOL/SPA TOTAL = WATTS
MISCELLANEOUS EQUIPMENT TOTAL = WATTS
TOTAL LOAD FOR DWELLING = 18122 WATTS
WATTS
MAIN SERVICE Load
ART: 220-2 TOTAL LOAD 18122 WATTS DIVIDED BY 220 VOLTS= 82 AMPS
(NOTE:FOR 120/240 VOLTS SYSTEM USE 240 VOLTS;120/208 VOLTS SYSTEM USE 208 VOLTS)
ART:220-10 MINIMUM SERVICE
TABLE 310-16 SERVICE ENTRANCE CONDUCTORS AWG,CU AWG, AL
TABLE 250-94 GROUNDING ELECTRODE CONDUCTOR AWG COPPER
Contact Information:
Mike Monaco
970-331-3605