Loading...
HomeMy WebLinkAboutB16-0254_170811 Town of Vail Comment Response Letter ES TOV_1507144370.pdfBaskervill, Inc. August 11, 2017 Town of Vail RE: DoubleTree by Hilton Vail, CO – Conversion Responses to Construction Change Directive #04 Review Comments Dear Danielle Thank you for your review of the Constructive Change Directive #04 submission for the DoubleTree by Hilton Vail Hotel. We appreciate your detailed comments and input. This letter is in response to your comments. Please let me know if there are questions or concerns with our direction. SHEET L-1 COMMENT: 1. Gas fire pits need more info – gas line drawings / clearances. RESPONSE: The L1 sheet included in CCD04 was mistakenly included in the set. This sheet was an older version and no changes have been made to the currently approved Landscaping. SHEET A-201 COMMENT: 2. Show exiting/egress from this area. Removing stair? RESPONSE: This comment is referring to the exterior stair that provided access to the roof top area above the first floor, and is called for removal in CCR04. This stair was solely for the purpose of access to the roof area that houses mechanical equipment and does not require an exit/egress stair per 2015 IBC, Section 1209.3 and 2015 IMC, Section 306.5 whereas the roof in that area is at 14’ A.F.F., and access to the roof area in question is primarily from the second floor office area. SHEET A-301 COMMENT: 3. 2015 IBC Section 1406.3, Exception #2, Balconies: Untreated wood is permitted for pickets and rails or guards, but are limited to 42 inches in height. RESPONSE: Acknowledged, balcony railings, guards, pickets and similar guardrail devices will be fire-retardant-treated using “Flame Safe Fire-Retardant” coating system as demonstrated on site. flame stop product not approved for new construction. coating has to be re-applied 10/04/17 Page 2 C:\Users\esikes\Documents\170811 Town of Vail Comment Response Letter ES TOV.docx COMMENT: 4. Stone on chimney shall match existing stone in size, shape, and color? RESPONSE: Acknowledged, as noted on the drawings, the stone on the exterior chimney(s) is to be “REUSE RECONDITIONED EXISTING NATURAL STONE VENEER FOR NEW FACING ON FIREPLACE CONSTRUCTION”. This note on the elevations refers to the fireplace/chimney(s). SHEET A-302 COMMENT: 5. Stone on chimney shall match existing stone in size, shape, and color? RESPONSE: Acknowledged, as noted on the drawings, the stone on the exterior chimney(s) is to be “REUSE RECONDITIONED EXISTING NATURAL STONE VENEER FOR NEW FACING ON FIREPLACE CONSTRUCTION”. This note on the elevations refers to the fireplace/chimney(s). SHEET A-303 COMMENT: 6. 2015 IBC Section 1406.3, Exception #2, Balconies: Untreated wood is permitted for pickets and rails or guards, but are limited to 42 inches in height? RESPONSE: Acknowledged, balcony railings, guards, pickets and similar guardrail devices will be fire-retardant-treated using “Flame Safe Fire-Retardant” coating system as demonstrated on site. SHEET A-306 COMMENT: 7. Signage under separate permit, and not approved with these plans. RESPONSE: Acknowledged, all signage permitting and approval are under separate submittal and review. SHEET A-402 COMMENT: 8. “Structural plan/detail” referring to Trellis Elevation post footings. RESPONSE: Acknowledged, these are detailed on the previously released/approved sheet S102 as prepared by SDL Structural Engineers. See attached previously submitted and approved sheet S102. SHEET A-501 COMMENT (4C FIREPLACE SECTION): 9. Wood not permitted FRTW? Metal?” RESPONSE: Acknowledged, fire-retardant treated wood to be used. See attached product specification sheets. COMMENT (3A ENTRY ROOF DETAIL): 10. Show code compliance provide information on heat panels. 10/04/17 Page 3 C:\Users\esikes\Documents\170811 Town of Vail Comment Response Letter ES TOV.docx RESPONSE: Acknowledged, all specifications and related information on the Low Voltage Heat Panels, and Flame Safe fire-retardant coating has been submitted for your review and a field demonstration has been provided to your satisfaction. See attached product specification sheets SHEET A-502 COMMENT: 11. Handrails both sides shall return to post/handrail both sides typical of all stairs. RESPONSE: Acknowledged, see attached revised sheet A502. Sincerely, Eugene Sikes, RA Architect 10/04/17