HomeMy WebLinkAboutB16-0254_E001_signed_1507144342.pdfSYMBOL DESCRIPTION
DUPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF,
SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE,
REFER TO LIGHTING CONTROL SYSTEM DIAGRAM,
SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT
DUPLEX RECEPTACLE, SPLIT WIRED, NEMA 5-20R, MOUNT
+18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE,
REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT
'H' INDICATES HORIZONTAL MOUNT
SINGLE RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF,
SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE,
REFER TO LIGHTING CONTROL SYSTEM DIAGRAM,
SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT
GFCI
RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF,
SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE,
REFER TO LIGHTING CONTROL SYSTEM DIAGRAM,
SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT
QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF,
SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO
LIGHTING CONTROL SYSTEM DIAGRAM
GFCI QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF,
SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO
LIGHTING CONTROL SYSTEM DIAGRAM
SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AND
MOUNTING AS INDICATED
BRANCH CIRCUIT HOMERUN, HATCH MARKS INDICATE TYPE AND
NUMBER OF CONDUCTORS, DASHED LINES INDICATE UNDER
FLOOR/GROUND ROUTING, PROVIDE 3#12 IN 3/4" CONDUIT
UNLESS OTHERWISE INDICATED.
INDICATES PHASE CONDUCTOR
INDICATES NEUTRAL CONDUCTOR
INDICATES GROUNDING CONDUCTOR
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MANUAL MOTOR STARTER
MAGNETIC MOTOR STARTER
COMBINATION STARTER/DISCONNECT
MOTOR
DUPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT
QUADRAPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT
FLOOR BOX, FLUSH FLOOR, WITH (2) DUPLEX RECEPTACLES AND
SPACE FOR (2) SINGLE GANG TELECOMMUNICATION OUTLETS
FLOOR BOX, POKE-THRU TYPE WITH (2) DUPLEX RECEPTACLES
AND SPACE FOR TELECOMMUNICATION OUTLETS
JUNCTION BOX
SYSTEM FURNITURE CONNECTION, WALL AND FLOOR MOUNT
PANELBOARD, SURFACE MOUNT
PANELBOARD, RECESS MOUNT
TRANSFORMER, DRY TYPE
PLUG LOAD CONTROLLER, MOUNT IN ACCESSIBLE ABOVE
CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM
DIAGRAM
DUPLEX RECEPTACLE, NEMA 5-20R, CEILING MOUNT, SUBSCRIPT
'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING
CONTROL SYSTEM DIAGRAM
SURFACE RACEWAY, DEVICES AS INDICATED
PLUGMOLD, OUTLET EVERY 12" ON CENTER, ALTERNATE NEMA
5-15R RECEPTACLE WITH USB CHARGING PORT
POWER LEGEND
GENERAL DEMOLITION NOTES
DEMOLITION DRAWINGS ARE PROVIDED AS REFERENCE ONLY. DEMOLITION
DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD INVESTIGATION AND
EXISTING DRAWINGS.
VISIT THE PROJECT SITE AND BECOME FAMILIAR WITH EXISTING FIELD
CONDITIONS PRIOR TO PROCEEDING WITH THE WORK.
CLEAN AND REPAIR ALL EQUIPMENT INDICATED FOR REUSE OR SALVAGE.
DISPOSE OF, IN A LEGAL MANNER, ALL MATERIALS INDICATED FOR REMOVAL AND
NOT INDICATED FOR REUSE OR SALVAGE.
MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS AND FEEDERS NOT
INDICATED FOR REMOVAL BUT MAY BE DISTURBED BY THE WORK. REROUTE
CIRCUITS AS REQUIRED DUE TO THE WORK.
EXISTING CONDUIT MAY BE ABANDONED IN THE WALLS, FLOOR SLAB, AND BELOW
GRADE ONLY. REMOVE CONDUITS TO THE SURFACE OF THE WALL/FLOOR AND
PATCH.
REMOVE UNUSED CABLING AND CONDUCTORS ALL THE WAY BACK TO THE
SOURCE.
1.
2.
3.
4.
5.
6.
7.
LIGHTING LEGEND
SYMBOL DESCRIPTION
LIGHT FIXTURE
LIGHT FIXTURE ON EMERGENCY/NON-SWITCHED POWER
LIGHT FIXTURE, WALL MOUNT
LIGHT FIXTURE, WALL MOUNT, ON EMERGENCY/NON-SWITCHED
POWER
LIGHT FIXTURE, POLE MOUNT
EXIT SIGN, WALL MOUNT +90" AFF AND CEILING MOUNT, SHADED
SIDE INDICATES FACE(S) OF SIGN, DIRECTIONAL CHEVRONS AS
INDICATED
EGRESS LIGHT WITH BATTERY PACK, WALL MOUNT +90" AFF
OCCUPANCY SENSOR, DUAL TECHNOLOGY, CEILING MOUNT,
OMNI-DIRECTIONAL AND DIRECTIONAL
PHOTO CELL
LIGHT SWITCH, 120/277-VOLT, 1HP RATED, MOUNT +46" AFF,
SUBSCRIPT INDICATES TYPE OF SWITCH:
3 - 3-WAY
4 - 4-WAY
D - DIMMING
K - KEY OPERATED
M - OCCUPANCY SENSOR
P - PILOT LIGHT
LIGHT SWITCH, LOW VOLTAGE, MOUNT +46" AFF, REFER TO
LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT INDICATES
TYPE OF SWITCH:
3 - 3-WAY
4 - 4-WAY
D - DIMMING
K - KEY OPERATED
M - OCCUPANCY SENSOR
P - PILOT LIGHT
ROOM CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING
SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM
LOW VOLTAGE CABLING FOR LIGHTING CONTROL SYSTEM,
REFER TO LIGHTING CONTROL SYSTEM DIAGRAM
SYMBOL DESCRIPTION
CCTV CAMERA
KEYPAD, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO
ACCESSIBLE ABOVE CEILING SPACE
CARD READER, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT
TO ACCESSIBLE ABOVE CEILING SPACE
CARD READER WITH KEYPAD, MOUNT +46" AFF, PROVIDE 3/4"
EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE
MAGNETIC LOCK
ELECTRIC STRIKE
ELECTRIC LOCK
GLASS BREAK SENSOR
SECURITY LEGEND
SYMBOL DESCRIPTION
TELECOMMUNICATIONS OUTLET, MOUNT +18" AFF, PROVIDE 1"
EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING
SPACE
TELECOMMUNICATIONS OUTLET, FLUSH FLOOR MOUNT, PROVIDE
1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE
CEILING SPACE
SOUND SYSTEM SPEAKER, CEILING AND WALL MOUNT
COAXIAL CABLE TELEVISION OUTLET, MOUNT +18" AFF
INTERCOM STATION, MOUNT +46" AFF
19" EQUIPMENT RACK
TELECOMMUNICATIONS OUTLET, CEILING MOUNT, PROVIDE 1"
EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE
TELECOMMUNICATIONS LEGEND
GENERAL NOTES
PROVIDE WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,
LOCAL ORDINANCES, AND AS APPROVED BY THE LOCAL AUTHORITY HAVING
JURISDICTION.
OBTAIN PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR
INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE
COMPLETION OF THE WORK.
PROVIDE LABOR, MATERIAL, AND OTHER SERVICES AS MAY BE NECESSARY TO
PROVIDE A COMPLETE AND FUNCTIONING SYSTEM.
NOTIFY THE ARCHITECT/ENGINEER AND RESOLVE ANY ISSUES EXPERIENCED
DURING THE COURSE OF THE WORK PRIOR TO EXECUTION OF THE WORK.
SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS:
A. LIGHT FIXTURES
B. PANELBOARDS / CIRCUIT BREAKERS
C. SAFETY SWITCHES
D. TRANSFORMERS
E. WIRING DEVICES
F. CONDUCTORS
G. CONDUIT
H. ALL OTHER ITEMS SPECIFIED BY MODEL NUMBER ON
DRAWINGS
SHOP DRAWINGS MUST BE APPROVED BY ENGINEER PRIOR TO PURCHASE. IF A
SUBSTITUTION IS PROPOSED, BE PREPARED TO PROVIDE SAMPLES FOR
EVALUATION.
PROVIDE MATERIAL WITHIN ONE YEAR OF MANUFACTURE, BEARING A U.L.
LABEL, AND LISTED FOR ITS INSTALLED APPLICATION.
PROVIDE MAJOR COMPONENTS OF THE ELECTRICAL SYSTEM BY THE SAME
MANUFACTURER.
USE MOUNTING HEIGHTS INDICATED ON THE LEGEND EXCEPT WHERE
INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS ARE MEASURED FROM THE
MIDDLE OF WALL MOUNTED DEVICES AND FROM THE BOTTOM OF PENDENT
MOUNTED DEVICES.
ASSEMBLE, HANG, AND CONNECT LIGHTING FIXTURES FURNISHED COMPLETE
WITH SOCKETS, TRIM HANGERS, SUPPORTS, ETC, AS REQUIRED FOR A
COMPLETE INSTALLATION. MOUNT LIGHT FIXTURES SUPPORTED
INDEPENDENTLY OF SUSPENDED CEILING COMPONENTS.
PROVIDE "LOCKING" TYPE DEVICES ON CIRCUIT BREAKERS CONNECTED TO
EMERGENCY LIGHTING, NIGHT LIGHTING, FIRE ALARM, AND SECURITY SYSTEMS.
IN FINISHED SPACES: FLUSH MOUNT LIGHT SWITCHES, RECEPTACLES, AND
TELECOMMUNICATIONS OUTLETS, ROUTE RACEWAYS CONCEALED.
PROVIDE MOTOR OVERLOAD DEVICES IN STARTERS BASED ON NAMEPLATE
RATING ON THE MOTORS BEING INSTALLED.
PROVIDE "HACR" TYPE CIRCUIT BREAKERS FOR CIRCUITS THAT SERVE
HEATING, AIR CONDITIONING, OR REFRIGERATION EQUIPMENT.
PROVIDE MINIMUM #10 NEUTRAL CONDUCTOR FOR MULTI-WIRE RECEPTACLE
BRANCH CIRCUITS.
PROVIDE SPLICES IN OUTLET OR JUNCTION BOXES ONLY.
PROVIDE UPDATED TYPE WRITTEN CIRCUIT DIRECTORY IN PLASTIC SLEEVE
FOR EACH PANELBOARD AFFECTED BY THE WORK.
PROVIDE U.L. APPROVED FIRE STOP SYSTEMS FOR PENETRATIONS THROUGH
FIRE AND SMOKE PARTITIONS TO MAINTAIN THE RATING OF THE PARTITION.
BOX-IN DEVICES ON FIRE/SMOKE PARTITIONS WITH FIRE RATED MATERIAL.
PROVIDE "AS-BUILT" DRAWINGS TO THE OWNER AT CONTRACT CLOSEOUT.
GUARANTEE WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER
OWNER ACCEPTANCE.
PERFORM ALL WORK IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (2014)
AND 2015 INTERNATIONAL BUILDING CODE. SEE ARCHITECTURAL TITLE SHEET
T001 FOR ADDITIONAL CODE REQUIREMENTS.
CONTRACTOR SHALL COMPLY WITH AND MAINTAIN A COPY OF (2015) FIRE
PROTECTION CODE AND NFPA 241-2000 "STANDARD FOR SAFEGUARDING
CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" ON SITE.
NOTIFY CONSTRUCTION MANAGER, OWNER , FIRE DEPARTMENT, AND
AUTHORITY HAVING JURISDICTION A MINIMUM OF SEVEN DAYS PRIOR TO ANY
FIRE ALARM OR SPRINKLER SYSTEM SERVICE INTERRUPTION. PROVIDE FIRE
WATCH IN ACCORDANCE WITH FIRE PREVENTION CODE (2012), PARAGRAPH
901.7. SERVICE INTERRUPTIONS SHALL BE CONFINED TO TIMES WHEN THE
BUILDING IS NORMALLY UNOCCUPIED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
SYMBOL DESCRIPTION
FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, MOUNT STROBE
LENS NOT LESS THAN +80" AFF AND NOT MORE THAN +96" AFF.
STROBE CANDELA RATING AS INDICATED
FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, MOUNT
STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN +
96" AFF. STROBE CANDELA RATING AS INDICATED
FIRE ALARM MANUAL PULL STATION, MOUNT +46" AFF
FIRE ALARM SMOKE DETECTOR, CEILING MOUNT
FIRE ALARM HEAT DETECTOR, CEILING MOUNT
FIRE ALARM DUCT SMOKE DETECTOR
FIRE ALARM TAMPER SWITCH
FIRE ALARM FLOW SWITCH
FIRE ALARM PRESSURE SWITCH
FIRE ALARM MONITOR MODULE
FIRE ALARM CONTROL MODULE
FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, CEILING MOUNT,
STROBE CANDELA RATING AS INDICATED
FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE,
CEILING MOUNT, STROBE CANDELA RATING AS INDICATED
MAGNETIC DOOR HOLD OPEN DEVICE
FIRE ALARM LEGEND
1P SINGLE POLE
2P DOUBLE POLE
3P THREE POLE
1PH SINGLE PHASE
3PH THREE PHASE
A AMPERES
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPERE INTERRUPTING CAPACITY
AL ALUMINUM
AMP AMPERE
AUTO AUTOMATIC
A/V AUDIO / VISUAL
AWG AMERICAN WIRE GAUGE
BFC BELOW FINISHED CEILING
BFG BELOW FINISHED GRADE
C CONDUIT
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CF COMPACT FLUORESCENT
CKT CIRCUIT
C/T CURRENT TRANSFORMER
CU COPPER
DEMO DEMOLITION
DISC DISCONNECT
ELEC ELECTRICAL
ELTG EXTERIOR LIGHTING
EM EMERGENCY
EQ EQUIPMENT
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOT CANDLE
FT FEET
FVNR FULL VOLTAGE NON-REVERSING
G GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTING
GFI GROUND FAULT INTERRUPTING
GND GROUND
HP HORSE POWER
IAW IN ACCORDANCE WITH
ILTG INTERIOR LIGHTING
IN INCHES
KCMIL KILO CIRCULAR MILLS
KVA KILO VOLT AMPS
KW KILO WATTS
KWH KILO WATT HOURS
LED LIGHT EMITTING DIODE
LTG LIGHTING
LTS LIGHTS
MCC MOTOR CONTROL CENTER
MISC MISCELLANEOUS
MTD MOUNTED
MTR MOTOR
N NEUTRAL
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NO. NUMBER
P/BD PANELBOARD
PR PRESENT TO REMAIN
PRI PRIMARY
PVC POLYVINYL CHLORIDE
PWR POWER
RCPT RECEPTACLE
RL RELOCATED
SEC SECURITY
SW SWITCH
SWBD SWITCH BOARD
TELECOM TELECOMMUNICATIONS
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLTS
W/ WITH
XFER TRANSFER
XFMR TRANSFORMER
ABBREVIATIONS
S S
J
SF SF
T
C
C
S
SD
H
TS
FS
PS
M
C
F
F
F
KP
CR
M
PC
M M
G
S
H
S
H
S
H
PC
I
I
I
S
H
RATED WALL LEGEND
SYMBOL DESCRIPTION
NON-RATED PARTITION
NON-RATED SMOKE RESISTIVE PARTITION
1 HOUR FIRE BARRIER
1 HOUR SMOKE COMPARTMENT BARRIER
2 HOUR FIRE BARRIER
2 HOUR SMOKE COMPARTMENT BARRIER
2 HOUR FIRE BARRIER
3 HOUR SMOKE COMPARTMENT BARRIER
CK
ML
ES
EL
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
9/19/2017
4:38:13 AM
LEGEND, SPECS,
LIGHTING FIXTURE
SCHEDULE
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/16 -
CONSTRUCTION
DOCUMENTS
E001
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
LIGHTING FIXTURE SCHEDULE
TYPE MANUFACTURER MODEL VOLTAGE
LAMPS
INPUT WATTS MOUNTING COMMENTS
QTY TYPE WATTS
C1 FEELUX ELS203000K-120 120 1 LED 20 W 20 COVE BALLROOM COVE THRU CONTROLS.VERIFY LENGTH OF RUN. PROVIDED BY CONTRACTOR
C2 FEELUX ELS103000K-120 120 1 LED 10 W 10 COVE BALLROOM COVE THRU CONTROLS.VERIFY LENGTH OF RUN. PROVIDED BY CONTRACTOR
C3 VOLT LIGHTING GROUP PH3K-24V 120 1 LED 10 W 10 MILL WORK PROVIDED BY CONTRACTOR.
C4 VOLT LIGHTING GROUP PL3K-24V 120 1 LED 10 W 10 MILL WORK PROVIDED BY CONTRACTOR
C5 PHILIPS LEDALITE 24G8LCGAG1611EB 120 1 LED 17 W SURFACE PROVIDED BY CONTRACTOR WITH END CAPS
C6 COMMERCIAL ELECTRIC 54261141 120 1 LED 30 W 32 SURFACE PROVIDED BY CONTRACTOR
F1 PHILIPS DAY-BRITE 2TG20L8302FS12FUNV 120 1 LED 23 W 72 RECESSED PROVIDED BY CONTRACTOR.
F1E PHILIPS DAY-BRITE 2TG20L8302FS12FUNVEMLED 120 1 LED 23 W 25 RECESSED PROVIDED BY CONTRACTOR
FP1 VOLT LIGHTING GROUP CUSTOM SQUARE "PUCK" 120 1 LED 11 W 15 RECESSED PROVIDED BY CONTRACTOR. CONTACT VOLT LIGHTING GROUP
L1 COOPPER LIGHTING S23DR 2L30 SR 8 120 DD S1 120 1 LED 11 RECESSED PROVIDED BY CONTRACTOR.
L1E COOPPER LIGHTING S23DR 2L30 SR 8 120 DD S1 120 1 LED 11 RECESSED PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP
LTG-401 TECH LIGHTING PETRONA 700PTNA 120 22 LED 100 W 100 PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR.
LTG-402 EUROFASE 20446-024 120 1 GU10 50 W 50 PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE
LAMPING.
LTG-403 120 22 W PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE
LAMPING.
LTG-600 120 0 W SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE
LAMPING.
P1 COOPER LIGHTING S23DIP 2L30 TGRID 8 DD S1EM
S93S
120 1 LED 11 PENDANT PROVIDED BY CONTRACTOR WITH REMOTE MOUNT EMERGENCY BACK-UP
R1 PHILIPS LIGHTOLIER P6RD10NZ10UVB / P6RD830VB /
P6RDCC
120 1 LED 7 W 10 RECESSED PROVIDED BY CONTRACTOR
R1E PHILIPS LIGHTOLIER P6RD10NZ10UVBEM/ P6RD830VB
/ P6RDCC
120 1 LED 7 W 10 PENDANT PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP
R2 PHILIPS LIGHTOLIER P6RD15NZ10UVB / P6RD830VB /
P6RDCC
120 1 LED 12 W 16 RECESSED PROVIDED BY CONTRACTOR
R2E PHILIPS LIGHTOLIER P6RD15NZ10UVBEM /
P6RD830VB / P6RDCC
120 1 LED 12 W 16 RECESSED
R3 PHILIPS LIGHTOLIER P6RD20NZ10UVB / P6RD830VB /
P6RDCC
17 W
R3E PHILIPS LIGHTOLIER P6RD20NZ10UVEMB /
P6RD830VB / P6RDCC
120 1 LED 17 W 16 RECESSED PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP
R4 PHILIPS LIGHTOLIER CP4RN / CP4RBO7830W 120 1 LED 11 W 11 RECESSED PROVIDED BY CONTRACTOR
S1 SPA AREA WALL SCONCE SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL.
S2 PUBLIC RESTROOMS SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL.
S3 GUESTROOM LOFTS SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL.
SR1 NICOR D-SERIES DLR56 2709-120-3K-BL 120 1 LED 11 W 15 RECESSED PROVIDED BY CONTRACTOR FIXTURE TO BE BLACK AND DIMMING.
SR2 LITHONIA 5G1MB LED M6 120 1 LED 11 W 15 RECESSED WALL WASHING, BLACK AND DIMMING. PROVIDED BY CONTRACTOR.
X1 DUALLITE HCX
X2 LITHONIA AFN DB
X3 LITHONIA AFN DB FWD 0 W
1 8/25/2016 FOR CONSTRUCTION SET
4 11/07/2016 ASI #2
10 9/15/17 CCD-06
09/07/2017
201709/0
10/04/17