HomeMy WebLinkAboutB17-0049_approved documents_1512757027.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspection Line: 970.479.2149
Construction
B17-0049 / Revision 002
Issued: 12/08/2017
TOWN OF VAIL
Property Information
Address: 1255 WESTHAVEN CIR B ( 210312106019 )
Unit #: B
Parcel Number: 210312106019
Legal Description: Subdivision: GLEN STREAM 45 PARCEL B
Contacts
Contact Type: Applicant
Full Name: Mark Scully
Address: Phone: 376-1807
Contact Type: Property Owner
Full Name: WESTHAVEN LLC
Address: 1825 K ST NW STE 507 WASHINGTON, DC 20006-1221 Phone: None
Contractor
Contractor Type: General
Company: Vail Custom Builders
State License #: Phone: 970-904-0512
Project Information
Project Name: Westhaven LLC/Lipnick Residence 2016
Project Description: REV2- Structural drawing to change boulder retaining wall to concrete retaining wall
Fees Paid
Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$14,551.25
Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$9,458.31
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$68,800.00
Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$6,000.00
Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$1,500.00
Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$2,250.00
Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$562.50
Account #: 111-0000.31127.00 - Recreation Fee Fee Amount:$1,077.15
Account #: 001-0000.31111.00 - Revision Fee Fee Amount:$605.00
Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00
Total Paid:$104,819.21
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
PERMIT FEE RECEIPT
Case # B17-0049.002
Date Printed: 12/08/2017
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B17-0049.002 Status: Approved
Permit Number: Date Started: 11/08/2017
Permit Type: Construction Subcases Single Family
Lot Number: 45
Property:
1255 WESTHAVEN CIR A (210312106018)
1255 WESTHAVEN CIR B (210312106019)
Contacts
Contact Type: Applicant
Company Name: Vail Custom Builders
Full Name: Mark Scully
Address:
Email: mark@vailcustom.com
Contact Type: Property Owner
Full Name: WESTHAVEN LLC
Address: 1825 K ST NW STE 507 WASHINGTON, DC 20006-1221
Permit Fees
Fee Information Account Amount
Revision Fee 001-0000.31111.00 $220.00
Payment Information Date Paid Payment Type Amount
Revision Fee 12/08/2017 Credit Card $220.00
Paid By: - Notes: Visa - Mark Scully
FEE TOTAL $220.00
AMOUNT PAID $220.00
BALANCE DUE $0.00
12/08/2017 - 11:11:14 AM - Generated by: dcouch75 South Frontage Road West, Vail, Colorado 81657
1 / 1
Departmentof Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970.479.2139
www.vailgov.com
TRANSMITTAL FORM
Use this form when submitting additional information, changes & inspection reports for building permits.
This form is also used for requesting a revision to building permits. A two hour minimum building review
fee of $110 will be charged upon reissuanceof the permit.
Subm it this form only to: cdev_submittal@vailgov.com. Deliverpaper plans to Community Develop-
ment or uploadyour revised/corrected plans to the appropriateproject in ProjectDox, when requested.
r - - ·J 1ourct &r1d7iiiP--------------------.!Application/Permit #(s) information applies to: II~Revisions
I()Deferred Submittal
( ) Response to Correction Letter ~attached copy of correction letter
~ther$frq C>/a. ;Q,( t),-q4,11>:r5rvI
.. ·.· - · - · · · · . · · c e . - · : . · :iProject Street Address: I\hf5' > fJ J?f./-/lq@A Gn~~
Description of Transmittal/List of Changes,Items Attached,
·lndic~hanged plan p a g e h I
(Number) (Street) (Suite#) i ~ tee{c/u w U..u<-l tu ~"TO
Building/ComplexName: _ _ _ _ _ _ _ _ _ _ , L/.cu-fy /lo'-<-(o(;f '/Ji{gri 4.hfA
.UaJLCuJk!i Ba.ild?rr h Cblfc/~& :e.k,j &tit
Applicant Information
: (architect, contractor, owner/owner's rep)
!Contact Name: ~/l:t/!((,Gc-t.l!y'
!Address:
·City t},.-~-v_a_.c._/_J_ _ s_ta-te-:-G -d--z-ip-:-<?1'-.-~-J-)... (use additional sheet ifnecessary)
r--------.--·-------------~~-·---------------·----------------··
i Contact Name: - - - - - - - - - - - - - - - - - - '·--------------··-----------..- - - - - - - - - - - - - - - - - - - - - - - ·;
! Contact Phone:
0--"7 , ~7 ; c;;:1 / Building Permits:I /V ./ "b - / I "·Revised ADDITIONAL Valuations (Labor & Materials)
/,l,4 .A /J- / .t.') 1 Jr. .. , /.J }·'/ p/l . (DO NOT include original valuation)
iContactE-Mail: vn"i"'tln< ...~ t/ll . l c/1. fiN(,,G!f/T lfl ~I/!
Building: $ N-ef--U - - - -
1hereby acknowledgethat I have read this application, filled out
in full the information required, completed an accurateplot plan,
and state that all the information as required is correct. I agreeto
Plumbing:
comply with the information and plot plan, to comply with all Town Electrical:
ordinances and state laws, and to build this structureaccording
to the town'szoning and subdivision codes, design reviewap-
proved, International Building d Residential Codes and other
xrdi~f t e &1/ appf"~ t ereto.
Mechanical:
Total:
;Owner/ Required)1- ··---------...---- --- ----·--· ·-----·-·-·--·--·----·--·--
i i
I
- - - ----------------- - - ··- - ·---------·-·------ - - - - - - ..............._I
Date Received:
21-Apr-2017
TOWN OF~ Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970.479.2139
www.vailgov.com
TRANSMITTAL FORM
Use this form when submitting additional information, changes & inspection reports for building permits.
This form is also used forrequesting a revision to building permits. A two hourminimum building review
fee of$11Owill be charged upon reissuance ofthe permit.
on&y to: cdev_aubmlttal@vallgov.com. Deliver paperplans to Community Develop-
YQ!JI:revfsed/coneded lans to the appropriate project in ProjectDox, when requested.
Application/Permit #(s) information applies to: 817 '""-ool/ q
f i Revisions dJ Response to Correction Letter _attached copy ofcorrection letter
dJDeferred Submittal
/;}. '55 {(/pgf-ha.iM-AJ.. c,..c_1--e
d]Other
Project Street Address:
Ct~c..)t td.f., lJp.Ffhe!~ Description ofTransmittal/ List ofChanges, Items Attached,
Indicate changed plan pages:
(Number) (Street) (Suite#)
Building/Complex Name: f31r().c_:,f v ~( tfoo ri c)a11;A./
~ tlfS>"vrJ .S I fro r-,Sift60 11 ~,1-0 c4
Applicant Information +o a Craw/ s;/JCIC.-('
(architect, contractor, owner/owner's rep)
Contact Name: ~ r /L. 5cu II:(I
Address:
! City State: Zip:(use additional sheet ifnecessary)
i: Contact Name: ----·····---·---··-------------------"------·-·-----·------·--~ - - - - - - -
Building Permits:iContact Phone: t:/7D 3 7(t;i I f'o 7 Revised ADDITIONAL Valuations (Labor & Materials)
iContact E-Mail: W;a-<{(_ ~
(/a; (Cu srf ~I c0 J!1 (DO NOT include original valuation)
Building:
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plotplan, Plumbing:
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town Electrical:
ordinances and state laws, and to build this structure according
to the town's zoning·and subdivision codes, design review ap- Mechanical:
proved, International Building an esidential Codes and other
ordinan s t plic e thereto. Total:
ix~--~-+----r-----~--------~
$~~~~~~~~
$~~~~~~~~
$~~~~~~~~
$~~~~~~~~-
$_ __.(') ....... · '-- - - - -
21-Apr-2017
By cgodfrey at 11:55 am, Mar 20, 2017
B17-0049
Air System Sizing Summary for Whole Building
Project Name: 16090-Lipnick Residence 03/13/2017
Prepared by: Rader Engineering Inc. 09:24AM
Air System Information
Air System Name Whole Building
Equipment Class UNDEF
Air System Type SZCAV
Number of zones 1
Floor Area 6140.0 ft²
Location Vail, Colorado
Sizing Calculation Information
Calculation Months Jan to Dec
Sizing Data Calculated
Zone CFM Sizing Peak zone sensible load
Space CFM Sizing Coincident space loads
Central Cooling Coil Sizing Data
Total coil load 7.5 Tons
Total coil load 90.0 MBH
Sensible coil load 87.7 MBH
Coil CFM at Aug 1600 5573 CFM
Max block CFM 5573 CFM
Sum of peak zone CFM 5573 CFM
Sensible heat ratio 0.973
ft²/Ton 818.3
BTU/(hr·ft²) 14.7
Water flow @ 10.0 °F rise 18.02 gpm
Load occurs at Aug 1600
OA DB / WB 88.9 / 64.7 °F
Entering DB / WB 76.0 / 61.2 °F
Leaving DB / WB 56.3 / 54.9 °F
Coil ADP 54.1 °F
Bypass Factor 0.100
Resulting RH 47 %
Design supply temp. 50.0 °F
Zone T-stat Check 1 of 1 OK
Max zone temperature deviation 0.0 °F
Central Heating Coil Sizing Data
Max coil load 128.7 MBH
Coil CFM at Des Htg 5573 CFM
Max coil CFM 5573 CFM
Water flow @ 20.0 °F drop 12.88 gpm
Load occurs at Des Htg
BTU/(hr·ft²) 21.0
Ent. DB / Lvg DB 68.5 / 97.4 °F
Humidifier Sizing Data
Max steam flow at Des Htg 7.79 lb/hr
Airflow Rate 5573 CFM
Air mass flow 18557.78 lb/hr
Moisture gain .00042 lb/lb
Supply Fan Sizing Data
Actual max CFM 5573 CFM
Standard CFM 4124 CFM
Actual max CFM/ft² 0.91 CFM/ft²
Fan motor BHP 0.76 BHP
Fan motor kW 0.61 kW
Fan static 0.50 in wg
Outdoor Ventilation Air Data
Design airflow CFM 0 CFM
CFM/ft² 0.00 CFM/ft²
CFM/person 0.00 CFM/person
Hourly Analysis Program v5.01 Page 1 of 2
3/13/17
Zone Sizing Summary for Whole Building
Project Name: 16090-Lipnick Residence 03/13/2017
Prepared by: Rader Engineering Inc. 09:24AM
Air System Information
Air System Name Whole Building
Equipment Class UNDEF
Air System Type SZCAV
Number of zones 1
Floor Area 6140.0 ft²
Location Vail, Colorado
Sizing Calculation Information
Calculation Months Jan to Dec
Sizing Data Calculated
Zone CFM Sizing Peak zone sensible load
Space CFM Sizing Coincident space loads
Zone Terminal Sizing Data
Zone Name
Design
Supply
Airflow
(CFM)
Minimum
Supply
Airflow
(CFM)
Zone
CFM/ft²
Reheat
Coil
Load
(MBH)
Reheat
Coil
Water
gpm
@ 20.0 °F
Zone
Htg Unit
Coil
Load
(MBH)
Zone
Htg Unit
Water
gpm
@ 20.0 °F
Mixing
Box Fan
Airflow
(CFM)
Whole House 5573 5573 0.91 0.0 0.00 0.0 0.00 0
Zone Peak Sensible Loads
Zone Zone Zone
Cooling Time of Heating Floor
Sensible Peak Sensible Load Area
Zone Name (MBH) Cooling Load (MBH) (ft²)
Whole House 90.2 Aug 1600 133.6 6140.0
Space Loads and Airflows
Zone Name /
Space Name Mult.
Cooling
Sensible
(MBH)
Time of
Peak
Sensible
Load
Air
Flow
(CFM)
Heating
Load
(MBH)
Floor
Area
(ft²)
Space
CFM/ft²
Whole House
001-Storage 1 3.1 Aug 1600 387 9.3 633.0 0.61
002-Wet Bar 1 6.5 Aug 1600 518 12.4 711.0 0.73
003-Bunk Room 1 2.8 Aug 1600 224 5.4 322.0 0.69
004-Bath 1 1.0 Aug 1600 18 0.4 94.0 0.20
005-Guest Bed 3 1 3.7 Aug 1600 247 5.9 238.0 1.04
007-Bath 1 1.7 Aug 1600 74 1.8 129.0 0.57
008-Laundry 1 0.4 Aug 1600 69 1.7 87.0 0.80
009-Guest Bed 1 1 3.6 Aug 1600 221 5.3 245.0 0.90
010-WIC 1 0.1 Aug 1600 7 0.2 36.0 0.20
011-Bath 1 1.2 Aug 1600 56 1.3 105.0 0.53
012-Guest Bed 2 1 4.1 Aug 1600 255 6.1 242.0 1.05
013-WIC 1 0.1 Aug 1600 6 0.1 29.0 0.20
014-Bath 1 1.0 Aug 1600 17 0.4 87.0 0.20
101-Garage 1 7.6 Aug 1600 560 13.4 652.0 0.86
102-Mud 1 2.6 Aug 1600 190 4.6 237.0 0.80
103-Powder 1 0.4 Aug 1600 9 0.2 30.0 0.31
104-Office 1 2.5 Aug 1600 179 4.3 190.0 0.94
105-Laundry 1 1.6 Aug 1600 27 0.7 96.0 0.29
106-Kitchen/Dining 1 18.1 Aug 1600 792 19.0 576.0 1.38
107-Living 1 10.0 Aug 1600 606 14.5 558.0 1.09
108-TV Room 1 6.4 Aug 1600 369 8.9 268.0 1.38
109-Powder 1 0.7 Aug 1600 43 1.0 36.0 1.19
110-Master Bed 1 6.6 Aug 1600 403 9.7 210.0 1.92
111-Master Bath 1 3.1 Aug 1600 151 3.6 184.0 0.82
112-Master Closet 1 1.4 Aug 1600 144 3.5 145.0 0.99
Hourly Analysis Program v5.01 Page 2 of 2
ELECTRICAL PERMIT
Contractor Information
Business Name: ________________________________________
Business Address: ______________________________________
City ______________________ State: _______ Zip: ____________
Contact Name: _________________________________________
Contact Phone: _________________________________________
Contact E-Mail: _________________________________________
I hereby acknowledge that I have read this application, filled out in full the
information required, completed an accurate plot plan, and state that all
the information as required is correct. I agree to comply with the infor-
mation and plot plan, to comply with all Town ordinances and state laws,
and to build this structure according to the town's zoning and subdivision
codes, design review approved, International Building and Residential
Codes and other ordinances of the Town applicable thereto.
X ___________________________________________________
Owner/Owner’s Representative Signature (Required)
Applicant Information
Applicant Name: ________________________________________
Applicant Phone: ________________________________________
Applicant E-Mail: ________________________________________
Additional Authorized ProjectDox Users
Full Name: ____________________________________________
E-Mail:________________________________________________
Full Name: ____________________________________________
E-Mail:________________________________________________
Project Street Address:
__________ ______________________________ ___________
(Number) (Street) (Suite #)
Building/Complex Name: ________________________________
Project Information:
Owner Name: __________________________________________
Parcel #_______________________________________________
(For Parcel #, contact Eagle County Assessors Office at (970)328-8640 or visit
www.eaglecounty.us/patie)
Provide BOTH square footage of area of work
AND Valuation (Labor & Materials)
Amount of SQ Ft.:__________________________________
Electrical $:_______________________________________
Project #: ________________________________________
Building Permit #: __________________________________
Electrical Permit #: _________________________________
Lot #: ____ Block # ____ Subdivision: __________________
Define Scope and Location of Work: __________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
(use additional sheet if necessary)
Work Class:
New ( ) Addition ( ) Remodel ( ) Repair ( )
Other ( ) _______________________________________
Type of Building: Single-Family ( ) Duplex ( )
Multi-Family ( ) Commercial ( ) Restaurant ( )
Other ( ) _______________________
Date Received:
Includes Temporary Service: ( ) Yes ( ) No
Electrical Permit Submittal Requirements Including Heat Tape Installation
__Floor plan / Site plan showing proposed work upancy Group listed on plans
__Load Calculations and one-line diagram when loads or circuits are being added __Building Type
NOTE: For Multi-Family and Commercial buildings—plans and calculations must be prepared by a Colorado Licensed Electrical Engineer
Department of Community Development
75 South Frontage Road West
Vail, CO 81657
Tel: 970-479-2139
www.vailgov.com
For Office Use Only:
Fee Paid: _________________________________________
Received From: ____________________________________
Cash _________ Check # ___________
CC: Visa / MC Last 4 CC # _________ Auth # _________
Rev. 2015-Dec
1255 Westhaven Cir.
Westhaven LLC and Janie Lipnick
2103 121 06 018/ 2103 121 06 019
TBD
Mark Scully/ Vail Custom Builders
970-926-8761
mark@vailcustom.com/ted@vailcustom.com
New single family r
residence
7104.65 sq/ft
196,492.00
KH Webb Architects/Kyle Webb
By cgodfrey at 11:56 am, Mar 20, 2017
B17-0049
E17-0029
Instructions for calculating ELECTRICAL permit fees:
The Electrical permit fees listed in this section are mandated by the State of Colorado, Colorado Revised Statute §12-23-
117(3). They are subject to review and adjustment annually. Fees are based on either RESIDENTIAL or ALL OTHER
FEES. Do not use both categories to determine your fees. Please note the Town of Vail still requests you list the valua-
tion of work on RESIDENTIAL permits as we report on this data. The State of Colorado allows local jurisdictions to
charge up to 15% above their mandated fees as listed below.
Inspections: Permit fees include TWO inspections only. For ALL additional inspections, including re-inspection for cor-
rections issued by the electrical inspector, a $57.50 fee is required. This fee must be paid before any additional inspec-
tions will be performed.
Construction Use Tax: See formula listed on page 1 in the Building Permit Fees section. Construction use tax will be
applied to any electrical permit with a valuation exceeding $10,000 where there is NO building work.
Will Call: $5.00 applied to every electrical permit. When calling for your inspection, simply state that you would like
“Will Call” and leave the best contact name and number. The inspector will call you on his or her way to your site.
Section A. RESIDENTIAL: This fee (based on the enclosed living area only) includes construction of, or remodeling or addition to a single family
home, a unit in a duplex, a condominium, or a town house. If you are only providing or changing a service and not wiring any portion on the above,
see section ‘B’ on page 5 for correct permit fee.
Square Footage for Living Area State Fee
TOTAL Fee with 15%
added
(1) Not more than 1,000 square feet 135.00 155.25
(2) 1,001 square feet and not more than 1,500 square feet 202.00 232.30
(3) 1,501 square feet and not more than 2,000 square feet 270.00 310.50
(4) Per 100 square feet in excess of 2,000 square feet 13.50 15.52
Example: 2235 sq ft home
The base fee for 2000 sq ft (of the 2235 sq ft total) is $310.50 (see item (3) above) 310.50
The remaining 235 sq ft is rounded up, per section (4) above, to 300 sq ft (3 x $15.52= $46.56) 46.56
TOTAL $ 357.06
Section B. ALL OTHER FEES including some residential installations that are not based on square footage (not in a living area, i.e. garage, shop,
and photovoltaic, etc.). Fees in this section are calculated form the total cost to customer, including electrical materials, items and labor—whether
provided by the contractor or the property owner. Use this chart for a service connection, a temporary meter, and all commercial installations. Such
fees shall be computed as follows: (See ‘C’ below for the permit fees for a mobile/modular home and travel trailer parks).
Valuation of Installation
(based on cost to customer of labor, materials and items)
State Fee
TOTAL Fee with
15% added
(1) Not more than $2,000 135.00 155.25
(2) $2,001 and above 13.50 15.52
Example: The cost of the installation is $5,150 (round up to $6,000)
The base fee is calculated from section (2) above divided by 1000; 6 x $15.52 = $93.12 93.12
Plus $155.25 155.25
TOTAL $ 248.37
TOTAL Fee with
15% added
C. Mobile/Modular home and travel trailer parks, per space 135.00 155.25
D. Re-inspection fee for all of the above 50.00 57.50
E. Add Fee for Extra inspections 50.00 57.50
F. Add Fee for Temporary heat release 67.50 77.63
4
Fee schedule per State of Colorado Fee Schedule: February 15, 2017
02/17/2017
Matt Wadey, P.E.
Alpine Civil Engineering
PO Box 97
Edwards, CO 81632
Subject: CONSTRUCTION PLAN APPROVAL – 1255 Westhaven Circle-Sewer Main Relocate
2/3/17 Plan Set
Dear Mr. Wadey,
This letter is to inform you that Construction Plan Approval has been granted for the above-referenced
project. The Applicant or designated representative, “Applicant Representative” shall act on Applicants
behalf and is responsible for compliance with the District’s Infrastructure Acceptance Procedure
requirements.
Please provide the following required plan sets indicated in the table below:
*Required Plans File Type Contact Email for Contact
Construction Plan Set PDF Inspector-Cindy Schmidt cschmidt@erwsd.org
Construction Plan Set Auto-CAD .DWG GIS Analyst-Larry Rector lrector@erwsd.org
*It is assumed that plans submitted will reflect all requirements as stated in the District specifications for water and
sewer lines. Any oversight by the Construction Review Team during the review process shall not be construed as
permission to construct anything that does not adhere to the District standard specifications. The District must grant
any deviation from the District standard specifications through written approval.
Once the required plans indicated above have been received and reviewed by the District, the Project
may proceed with Initiation of Construction by scheduling the mandatory Pre-Construction with the District
Inspector. The Applicant/ Applicant Representative shall allow a minimum of three business days, prior to
scheduling the Pre-Construction meeting with the District Inspector.
Upon successful completion of all construction inspections and testing have occurred for the Project the
Applicant/ Applicant Representative must submit the following required documents to the District in order
to receive Construction Acceptance, start the warranty period, and be eligible for service.
DRAWINGS OF RECORD
"Field Verified" As-Built drawings in Auto-CAD .DWG and PDF, per the District's specifications, are required.
EASEMENT DOCUMENTATION
Descriptions of dedicated easements or road right-of-way in which the water main is installed as required.
PROJECT COST
An accounting of the exact construction cost of the line that the District is being asked to accept. This amount shall
only include the cost of design, materials, and installation of the water main. Legal costs are not an eligible cost.
BILL OF SALE
A document conveying the water main to the District by the developer/owner is required. This document warrants the
water main against any and all defects as required. The appropriate Bill of Sale form shall be obtained from the
District.
Page 2 of 2
The Warranty Period shall not start until Drawings of Record, recorded Easement Documents, Project
Cost documents, and Bill of Sale, have been completed, and are received and approved by the District.
The Construction Acceptance Letter will be issued once all required submissions have been approved by
the Development Review Coordinator. The date of issuance of the letter is the start of the Warranty
Period.
If you have any questions or concerns, please contact Tug Birk at (970) 477-5449.
Sincerely,
Tug Birk
Development Review Coordinator
CC: Mike Thompson
Cindy Schmidt
Larry Rector
Customer Service
H-P~KUMAR IGeotechnical EngiJleering IEngineering Geology
Materials Testing 1:Environmental
5020 CountyRoad 154
Glenwood Springs, CO 81601
Phone: (970) 945-7988
Fax: (970) 945-8454
Email: hpkglenwood@kumarusa.com
June 26, 2017
Office Locations: Parker, Glenwood Springs, and Silverthorne, Colorado
Vail Custom Btilders
Attn: Mark Scully
P. 0 . Box 2809:I,Ec1wards, Color:ado 81632
mark@vailcustom.com
Project No. 16-7-586.A
Subject:Observation of Excavation, Proposed Lipnick Residence, Lot 45, Glen LyonI,
Dear Mark:
Subdivision, 1255 Westhaven Circle, Vail, Colorado;'
As requested, a representative of H-P/Kumar observed the excavation at the subject site on about
eleven visits betweenMay 10 and June 19, 2017 to evaluate the soil conditions exposed for
foundation support. The findings of our observations and recommendations are presented in this
report. The services were performed in accordance withour agreementfor professional
engineering services to Vail Custom Builders, dated May 1, 2017.
, We previously:conducted a subsoil study for design of foundations at the site and presented our
findings in a report dated December 15, 2016, Project No. 16-7-586. The proposed construction
is similar to that discussed in the previous report. The buildinghas been designed to be
supported on spread footings sized using an allowable soil bearing pressure of 2,000 psf, as
recommended.
On May 10, we visited the site to observe two backhoe pits excavated in an existing fill area in
the northeastern portion of the proposed residence. At this time, the existing residence on the
site had been removed. The pits encountered considerable existingfill with natural coarse
granular soils encountered at about elevation8044 to 8046 feet, and no free water. At this time,
we recommended the existing fill be removed to bear the footings on the natural coarse granular
soils.
On May 25, the excavation had initially began in the northern and eastern portion of the
proposed resid~nce with the existing fill being encountered that was being removed to below
design footing 1bearing elevation. By May 31 and June 5, the excavation continued and was
nearing compl~tion with ~onsiderable sub-excavation of old fill needed to achieve suitable
granular beating soils at subgrade. On about June 12, stiff gravelly clay soils were observed at
below the sub-excavated fill in the southeast portion of the excavation that was sampled and not
tested due to the 2 to 3 feet depth of the material subsequently being removed to more suitable
bearing soils. The existing fill depth at the site where encountered was up to about 8 feet below
design footing bearing elevation in areas.
Vail Custom Builders
June 26, 2017 ,
Page2
At the time of bur June 19 site visit, the foundation excavation was essentially complete,
including the e~terior footing pad areas, and had been cut in multiple levels from about 3 to 13
feet below the adjacent ground surface. The soils exposed in the bottom of the excavation
consisted of relatively dense, silty occasionally clayeysandy gravel to sand and gravel with
cobbles and s4ttered boulders. All existing fill and unsuitable natural soils had been removed in
the proposed f6oting areas. The results of a gradation analysis performed on a sample of natural
coarse granular soils (minus 3-inch fraction) obtained from the site are presented on Figure 1.
No free water was encountered in the excavationand the soils were generally moist. In the west-
central portion of the excavation, there was about an 8 feet in diameter boulder exposed that
extended up a few feet above excavation subgrade but was below planned lower floor level in
this area. !:
The soil conditions exposed in the excavationare generally consistent with those previously
encountered on the site and suitable for support of spread footings designed for the
recommended 'allowable bearing pressure of 2,000 psf. Loose and disturbed soils should be
removed in the footing areas to expose the undisturbed natural coarse granular soils, and the
subgrade compacted. We understand the foundation will be designed to structurally span the
exposed boulder which will be done by the structural engineer. Other recommendations
presented in o~r previous report which are applicable should also be observed.
The recommer'idations submitted in this letter are based on our observation of the soils exposed
within the fou~dation excavation and the previous subsurface exploration at the site. Variations
in the subsurf~ce conditions belowthe excavation could increase the risk of foundation
movement. We should be advised of any variations encountered in the excavation conditions for
possible changes to recommendations contained in this letter. Our services do not include
determining the presence, prevention or possibilityof mold or other biologicalcontaminants
(MOBC) dev~loping in the future. If the client is concerned about MOBC, then a professional in
this special fi~~d of practice should be consulted.
IIf you have any questions or need further assistance, please call our office.
Sincerely,
H-P~KUMAR
Project No. 16-7-586.A
r '
0wz
~
w0::
1-zw(.)
0::w0...
HYDROMETER ANALYSIS I SIEVE ANALYSIS I
I U.S. STANDARD SERIES I CLEAR SQUARE OPENINGS I1. H TIME READINGS 24 HR. 7 R I0 45 MIN.15 MIN. 60MIN19MIN.4 MIN. 1 MIN. #200 #100 #50 #30 3/8" 3/4" 1 1/2" 3" 5" 6"8" 100#16 #8 #4
10
20
30
40
50
60
70
80
90
100
.001
,.
"
""
.002 .005 ,.009 019
CLAYTOSILT
GRAVEL 33 ~
I
uo01DLIMIT·:..,
.074 .150 .300 .600 1.18 2.36 4.75 9.5 19.0 37.5
12.5 76.2 152 203127.037
DIAMETER OF PARTICLES IN MILLIMETERS
GR.o\VELSAND COBBL.ESCOARSE FiNE COARSEFlNEMEO<UM
SAND 45 % SILT AND CLAY 22 %
% PLASTICITY INDEX %
SAMPLE OF: ;Silty Sand and Gravel FROM: Bottom of Excavation, 5/31/17
90
80
70
60
50
40
30
20
10
0
(;!)
zV5(f)
<(
0...
1-zw00::w0...
16-7-586.A H-P~I<UMAR GRADATION TEST RESULTS Figure 1
REScheck Software Version 4.6.2
Compliance Certificate
Project Lipnick Residence
Energy Code: 2015 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 6,140 ft2
Glazing Area 23%
Climate Zone: 6 (9248 HDD)
Permit Date:
Construction Site:
1255 Westhaven Circle
Vail, CO 81657
Owner/Agent:
Robert Lipnick
1255 Westhaven Circle
Vail, CO 81657
301-938-0585
RNLipnick@gmail.com
Designer/Contractor:
Heather Barrie
K.H. Webb Architects
710 West Lionshead Circle
Unit A
Vail, CO 81657
970-477-2990
heather@khwebb.com
Permit Number:
Compliance: Passes using UA trade-off
3.7% Better Than Code Maximum UA: 1166 Your UA: 1123
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Roof: Flat Ceiling or Scissor Truss 3,399 22.0 27.5 0.020 68
Above Grade Walls: Wood Frame, 16" o.c. 6,912 14.0 10.0 0.043 228
Windows (U=0.29): Wood Frame:Double Pane with Low-E 517 0.290 150
Windows (U=0.39): Wood Frame:Double Pane with Low-E 280 0.390 109
Glass Doors (U=0.29): Glass 323 0.290 94
Glass Doors (U=0.34): Glass 260 0.340 88
Glass Doors (U=0.39): Glass 210 0.390 82
Solid Doors: Solid 29 0.300 9
Below Grade Walls: Solid Concrete or Masonry
Wall height: 11.0'
Depth below grade: 11.0'
Insulation depth: 11.0'
1,979 14.0 10.0 0.031 61
Floor Over Outside: All-Wood Joist/Truss:Over Outside Air 105 38.0 0.0 0.026 3
Slab on Grade: Slab-On-Grade:Heated
Insulation depth: 6.0'
337 10.0 0.684 231
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 1 of10
03/13/17Report date:
3/13/17
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Calcs By: Joey Brenner - Rader Engineering (970)-845-7910
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 2 of10
03/13/17Report date:
Joey Brenner - Mechanical Engineer 3/13/17
Inspection Checklist
Requirements: 0.0% were addressed directly in the REScheck software
REScheck Software Version 4.6.2
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Pre-Inspection/Plan Review Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
103.1,
103.2
[PR1]1
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Complies
Does Not
Not Observable
Not Applicable
103.1,
103.2,
403.7
[PR3]1
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
Complies
Does Not
Not Observable
Not Applicable
302.1,
403.7
[PR2]2
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 3 of10
03/13/17Report date:
Section
#
& Req.ID
Foundation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.2
[FO1]1
Slab edge insulation R-value. R-_____
Unheated
Heated
R-_____
Unheated
Heated
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.2
[FO3]1
Slab edge insulation
depth/length.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1
[FO4]1
Conditioned basement wall
insulation R-value. Where interior
insulation is used, verification
may need to occur during
Insulation Inspection. Not
required in warm-humid locations
in Climate Zone 3.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[FO5]1
Conditioned basement wall
insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
402.2.9
[FO6]1
Conditioned basement wall
insulation depth of burial or
distance from top of wall.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2.1
[FO11]2
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
Complies
Does Not
Not Observable
Not Applicable
403.9
[FO12]2
Snow- and ice-melting system
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 4 of10
03/13/17Report date:
Section
#
& Req.ID
Framing / Rough-In Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.3.4
[FR1]1
Door U-factor. U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1,
402.3.1,
402.3.3,
402.3.6,
402.5
[FR2]1
Glazing U-factor (area-weighted
average).
U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.3
[FR4]1
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
Complies
Does Not
Not Observable
Not Applicable
402.4.1.1
[FR23]1
Air barrier and thermal barrier
installed per manufacturer’s
instructions.
Complies
Does Not
Not Observable
Not Applicable
402.4.3
[FR20]1
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
Complies
Does Not
Not Observable
Not Applicable
402.4.5
[FR16]2
IC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate ≤2.0 cfm
leakage at 75 Pa.
Complies
Does Not
Not Observable
Not Applicable
403.2.1
[FR12]1
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
Complies
Does Not
Not Observable
Not Applicable
403.3.3.5
[FR15]3
Building cavities are not used as
ducts or plenums.
Complies
Does Not
Not Observable
Not Applicable
403.4
[FR17]2
HVAC piping conveying fluids
above 105 ºF or chilled fluids
below 55 ºF are insulated to ≥R-
3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.4.1
[FR24]1
Protection of insulation on HVAC
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.3
[FR18]2
Hot water pipes are insulated to
≥R-3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.6
[FR19]2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 5 of10
03/13/17Report date:
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 6 of10
03/13/17Report date:
Section
#
& Req.ID
Insulation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
303.1
[IN13]2
All installed insulation is labeled
or the installed R-values
provided.
Complies
Does Not
Not Observable
Not Applicable
402.1.1,
402.2.6
[IN1]1
Floor insulation R-value. R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2,
402.2.7
[IN2]1
Floor insulation installed per
manufacturer’s instructions and
in substantial contact with the
underside of the subfloor, or floor
framing cavity insulation is in
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
Complies
Does Not
Not Observable
Not Applicable
402.1.1,
402.2.5,
402.2.6
[IN3]1
Wall insulation R-value. If this is a
mass wall with at least ½ of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_____
Wood
Mass
Steel
R-_____
Wood
Mass
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[IN4]1
Wall insulation is installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 7 of10
03/13/17Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.2.1,
402.2.2,
402.2.6
[FI1]1
Ceiling insulation R-value. R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.1.1,
303.2
[FI2]1
Ceiling insulation installed per
manufacturer’s instructions.
Blown insulation marked every
300 ft².
Complies
Does Not
Not Observable
Not Applicable
402.2.3
[FI22]2
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Complies
Does Not
Not Observable
Not Applicable
402.2.4
[FI3]1
Attic access hatch and door
insulation ≥R-value of the
adjacent assembly.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
402.4.1.2
[FI17]1
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
ACH 50 =_____ ACH 50 =_____ Complies
Does Not
Not Observable
Not Applicable
403.2.3
[FI4]1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur during Framing Inspection.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2
[FI27]1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer’s air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer’s air
handler enclosure.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2.1
[FI24]1
Air handler leakage designated
by manufacturer at <=2% of
design air flow.
Complies
Does Not
Not Observable
Not Applicable
403.1.1
[FI9]2
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
Complies
Does Not
Not Observable
Not Applicable
403.1.2
[FI10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Not Observable
Not Applicable
403.5.1
[FI11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 8 of10
03/13/17Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
403.6.1
[FI25]2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits.
Complies
Does Not
Not Observable
Not Applicable
403.2
[FI26]2
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.1
[FI28]2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.2
[FI29]2
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.2
[FI30]2
Water distribution systems that
have recirculation pumps that
pump water from a heated water
supply pipe back to the heated
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104ºF.
Complies
Does Not
Not Observable
Not Applicable
403.5.4
[FI31]2
Drain water heat recovery units
tested in accordance with CSA
B55.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
Complies
Does Not
Not Observable
Not Applicable
404.1
[FI6]1
75% of lamps in permanent
fixtures or 75% of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage
lighting.
Complies
Does Not
Not Observable
Not Applicable
404.1.1
[FI23]3
Fuel gas lighting systems have
no continuous pilot light.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 9 of10
03/13/17Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
401.3
[FI7]2
Compliance certificate posted. Complies
Does Not
Not Observable
Not Applicable
303.3
[FI18]3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lipnick Residence
Data filename: J:\Jobs\2016 - Jobs\16090.00 - Lipnick
Residence\Mechanical\Calculations\Rescheck\16090-Rescheck.rck
Page 10 of10
03/13/17Report date:
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
24.00Above-Grade Wall
24.00Below-Grade Wall
10.00Floor
49.50Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.29Window
0.29Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:
Comments