HomeMy WebLinkAboutB17-0049_EL10_1494616933.pdfDN
GUEST
BEDROOM #1
GUEST
BEDROOM #2
GUEST
BEDROOM #3
BUNK
ROOM
BATH
WIC
STORAGE
LAUNDRY WET BAR
BATH
TUB
WC
ELECTRICAL
ROOM
WIC
SHWR
WC
LOWER LEVEL
8057'
BENCH
PATIO
8057'
LOWER LEVEL
8057'
TP STORAGE
ABOVE
LINE OF DECK ABOVE
LINE OF DECK ABOVE
UP
TUB
STORAGE LEVEL
8061.65'
STORAGE LEVEL
8061.65'
MECHANICAL
LINE OF FLOOR ABOVE
LINE OF FLOOR
ABOVE
WIC
SHWR
SHWR
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF 10'-0" FIN CEILING
AFF
10'-0" FIN CEILING
AFF
8'-0" FIN CEILING
AFF
MANUAL SHADE POCKET
MANUAL DRAPERY POCKET
MANUAL SHADE POCKET
MANUAL DRAPERY POCKET
MANUAL SHADE POCKET
MANUAL DRAPERY POCKET
MANUAL SHADE POCKET
MANUAL DRAPERY POCKET
MANUAL SHADE POCKET
MANUAL DRAPERY POCKET
MANUAL SHADE POCKET
MANUAL DRAPERY POCKET
MANUAL
SHADE
POCKET
MANUAL
DRAPERY
POCKET
MANUAL
SHADE
POCKET
MANUAL
DRAPERY
POCKET
MANUAL
SHADE
POCKET
MANUAL
DRAPERY
POCKET
P P P
P
P
P
W
W W
W
WALL MOUNTED ADJUSTABLE
READING LIGHTS WITH
INTEGRAL CONTROLS;
(1) PER BUNK
FP
FP
S
C
C
C
ST1 ST1
ST1
ST1
IN-WALL STEPLIGHT
IN WC; TYP FOR ALL
WC'S
L2
INVERSE
COVE
L2
INVERSE
COVE
L2 INVERSE
COVE
L3
L1
UNDERCABINET LIGHT
UPLIGHT FROM
UPPPER CABINETS
L1
LIGHT STRIP UNDER
VANITY
L1
L1
L1
ART ART
ZANEEN "CANDLE"
FIXTURE IN ALL
DOWNSTAIRS CLOSETS;
TYP.
P
VERIFY QUANTITY AND
LOCATION(S) OF FLOOR
OUTLETS
C
A5
A5
A5
A5
A5
A5
A5
A5
A5
L4
A5
L1
SHELF
LIGHTING;
TBD
W W W W
48"L6
48"L648"L648"L6
48"48"48" L6 48" L6
L6
L6
48" L6 48" L6
48" L6
A4A4 A4 A4
A4
A4 A4
S2
L1
LIGHT STRIPS IN SHELVES
A1
S2
A5
A1
48" L6
MS
A1
A1
A5
MS
MS
A1
48" L6
MS
A5 A5 A5
A5
A5 S
S
S
MS
W
LIGHT ABOVE DOOR
A5
A1 A1 A1
W W W
S
SSS A5 A5
A5
S
S
SSSLIGHTING WITHIN
BUILT-INS
L1
LIGHT CHANNEL
UNDER HANDRAIL SSS
A5 A5 A5
A5 A5
A5
A5
A5 S
SS3D
4D
SS
SSS
S
S
S2
A5 A5
A5
A5 A5 C/L OTTOMAN
L1
A1
A1
A1
L7
W
P P
W
W
A5
TRIMLESS LINEAR TO
WASH WALL
4
3D
3
A1
C/L BED
EQ 1/2
EQ 1/2 EQ
C/L FIREPLACE
A1
A1
A1
A1
A1
A5 A5 A5
A5
A5
A5
A5
A5
EQ 1/2
EQ 1/2
EQ
S
S3
SS4
S3
4D
S3
S
3D
S
3
3D 4S4 S3
P
P SS
A5 A5 A5
A5
A5
A5
A5
A5
EQ 1/2 EQ 1/2
EQ
S
3D
S
3
3D 4S4
S3C/L BED
C/L BED
S4D
SA5
SS
D
D
D
SSD
D
S
SS SS
3
SS 3
D
A5
3D
3D
3D 4 4 4
3
3
D
D
D
D
D
FP00
000
000
000
000
000
FP00
000
SSS
D
D
D
SS
D D
SSS
SSD
D
D
D
D
SSD
D
000
000
A1 A1
A1 A1
A1
A1
A1
000
ALIGN
ALIGN
000
20
21
22
23
24
ACCESS PANEL
A5 A5
SD SD
CO2
SD SD
SD
CO2
SD
SD
SD
SD
SD LIPNICK
RESIDENCE
VAIL,
COLORADO
REVISION/ISSUE DATE
PROGRESS SET 2017-02-23
PROGRESS SET 2017-03-03
PRICING SET 2017-03-13
PRICING SET 2017-03-16
SHEET NUMBER:
186 LIGHTING DESIGN GROUP,INC.
1200 BANNOCK ST.
DENVER, CO 80204
TEL:303.534.5350
www.186group.com
LOWER LEVEL LIGHTING PLAN
1/4" = 1'-0" EL-1.0
05/12/17