Loading...
HomeMy WebLinkAboutB17-0453_A720.2_1513876493.pdfEXTERIOR BUILDING SYSTEMS NAMING SYSTEM TYPES PWS = PARAPET WALL SYSTEM RS = ROOF SYSTEM SS = SOFFIT SYSTEM CS = CEILING SYSTEM WS = WALL SYSTEM GS = GLAZING SYSTEM FS = FLOOR SYSTEM FWS = FOUNDATION WALL SYSTEM EXTERIOR BUILDING SYSTEMS 1. EXTERIOR BUILDING SYSTEMS SHEETS SHOW SYSTEM COMPONENTS. REFER TO SECTION AND DETAILS FOR RELATIONSHIPS BETWEEN BUILDING SYSTEMS FINISH TYPES EPDM = EPDM TPO = TPO PVC = PVC STO = STONE WD = WOOD MET = METAL MAS = MAS STU = STUCCO CMU = CMU WW = WINDOW WALL SF = STOREFRONT CW = CURTAIN WALL DP = DAMP PROOFING WP = WATER PROOFING EXAMPLE SYSTEM TYPE FINISH TYPE # - SYSTEM TAG PWS-MET2A DOOR / FRAME MATERIAL: AL/G - ALUMINUM GLASS HM - HOLLOW METAL WD - WOOD PT - PAINTED STAIN - STAINED MFR - MANUFACTURER DOOR FINISH: PL# - PLASTIC LAMINATE ST - STAINED, SEE BELOW CA - CLEAR ANODIZED PT - PAINTED KF - KYNAR FINISH GL - GLASS STAIN FINISH CODES ST0 = MATCH EXISTING ADJACENT FINISH WITHIN THE SUITE (COMMENT: MSA AREA, MISC.) ST1 = TO MATCH VT INDUSTRIES 'RAVINE RA07' (COMMENT: ADMIN DOORS EXCEPT NORTH ENTRY DOOR) ST2 = TO MATCH MARSHFIELF 'NUTMEG' (COMMENT: CORRIDOR DOORS, BLDG STD) DOOR NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS. 2. REFER TO SPECIFICATIONS FOR HARDWARE TYPES AND SCHEDULE. 3. ALL FIRE RATED DOORS SHALL HAVE UNDERWRITERS LABEL ON DOOR AND FRAME. 4. WHERE EXISTING DOORS TO REMAIN, TOUCH UP SCUFFING TO MAKE DOOR FINISH LIKE-NEW. 5. AT EXISTING DOORS IN SCOPE: WHERE SCUFFED,PATCH AND REFINISH TO LIKE-NEW CONDITION. IN AREA C, REFINISH EXISTING DAMAGED DOORS AND DOOR FRAMES. DOOR AND HARDWARE SCHEDULE - ABBREVIATIONS LEGEND/NOTES FRAME NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS PRIOR TO ORDERING OR FABRICATING ANY FRAMES. 2. ALL ELEVATIONS ARE DRAWN FACING THE EXTERIOR OF THE WINDOW FRAME. 3. STOREFRONT FABRICATOR TO PROVIDE REINFORCING AS REQUIRED 4. ALL DIMENSIONS ARE TO MASONRY OR ROUGH OPENING UNLESS NOTED OTHERWISE, PROVIDE PROPER SHIM CLEARANCE AS REQUIRED. 5. AT EXISTING FRAMES IN SCOPE: WHERE SCUFFED, PATCH AND REFINISH TO LIKE-NEW CONDITION GLAZING TYPES S = PROVIDE TEMPERED GLASS IN NON-RATED DOORS WHERE INDICATED. F = PROVIDE FIRE- PROTECTION-RATED GLASS MEETING OR EXCEEDING THE RATING OF THE DOOR ASSEMBLY WHERE INDICATED SEE SPECIFICATION FOR ACCEPTABLE GLASS TYPES. SINGLE FLUSH F1 RE: SCHEDULERE: SCHED. SINGLE OR DOUBLE DOOR FRAME HM1RE: SCHEDULE 2"2" RE: SCHED. 2" / D4 A720.2 /C4A720.2 / B4 A720.2 WS_STUCCO1C BASIS-OF-DESIGN: MODIFIED DOW THERMAX X-ARMOR WALLSYSTEM WITH LIQUIDARMOR FLASHING AND SEALANT ON THERMAX XARMOR INSULATION. 09 2400 - EXTERIOR PLASTERWORK TO MATCH EXISTING 09 2900 - EXTERIOR GYPSUM BOARD SECTION 07 4265 - 4 MIL FOIL-FACED POLYISOCYANURATE FOAM-PLASTIC BOARD 5/8" 3 5/8" 5/8" 2" 5/8" 1" 09 2900 - INTERIOR GYPSUM BOARD 09 2900 - GYPSUM BOARD, TYPE X 05 1200 - GALVANIZED STEEL LOOSE LINTEL 08 1113 - EXTERIOR HOLLOW-METAL FRAME 06 1600 - WALL SHEATHING EXISTING BRICK VENEER 07 9200 - JOINT SEALANT 09 2900 - INTERIOR GYPSUM BOARD 05 4000 - STEEL STUD 05 4000 - SINGLE DEFLECTION TRACK 05 4000 - SINGLE DEFLECTION TRACK EXISTING WALL 07 1413 - ELASTOMERIC FLASHING SHEET WEEP 07 6200 - SHEET METAL FLASHING FROM FACE OF BRICK 1" 09 2900 - INTERIOR GYPSUM BOARD 05 4000 - STEEL STUD 07 9200 - JOINT SEALANT 08 1113 - EXTERIOR HOLLOW-METAL FRAME 07 6200 - SHEET METAL FLASHING 07 1413 - ELASTOMERIC FLASHING SHEET 06 1600 - WALL SHEATHING EXISTING BRICK VENEER EXISTING WALL FROM FACE OF BRICK 1" LEVEL 2_CENTRAL 110' - 6" 08 1113 - METAL THRESHOLD 07 9200 - JOINT SEALANT 03 3000 - CAST-IN-PLACE CONCRETE 03 3000 - JOINT FILLER STRIP DOWL INTO EXISTING, RE: STRUCTURAL EXISTING SLAB EXISITING BRICK VENEER 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, 1 2 3 4 5 6 A B C D E 1 2 3 4 5 6 A B C D E Sheet Title: Consultant Revision Date Sheet Information Project Information Original Issuance 10/26/2017 3:23:35 PM15924.00 A720.2 2017 EAST WING ADDITION 180 S. Frontage Road West, Vail, CO 81657DOOR SCHEDULE, PARTITION TYPES, WALL SYSTEMS, AND DETAILS 10/25/2017DP2 VAIL HEALTH DOOR SCHEDULE ROOM LEAF FRAME Hardware Set Fire Rating Wall Width Remarks REVNAME Door Type Door Material Finish Width Height Thickness Door Glass Type Frame Type Frame Material Frame Finish LEVEL 2_CENTRAL 122Y STAIR 01 F1 WD PT 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 1 45 1' - 2" 1/4" = 1'-0" DOOR TYPES 1/4" = 1'-0" FRAME TYPES 3" = 1'-0"D4 EXTERIOR DOOR HEAD 3" = 1'-0"C4 EXTERIOR DOOR JAMB 3" = 1'-0"B4 EXTERIOR DOOR SILL 12/21/17