Loading...
HomeMy WebLinkAboutboiler spec sheet.pdfs.-. 0 TriangleTube Stainless Steel Fire Tube • Heat Exchanger 95%AFUE • Low Pressure Drop • Proven Performance • 2" to 4n Venting • Multiple Termination Options • Low NOx -2012 SCAQMD Certified • 5 Models from 60 to 399 MBH • 2 Year Control & Blower Warranty• Featuring TrlMax eon1ro1 with: • 60 Second Set•Up • Integrated Cascade E • Two Reset Curves/Set Points • Control of 4 Circulators I prestige -Leader in Contractor Friendlu Features TriMax Control 60 Second Set-Up Choose from 6 standard applications to set up the boiler in 60 seconds or less. • Finned Tube Baseboard • High Mass Radiant • Cast Iron Baseboard • Low Mass Radiant • Radiators • Fancoil Integrated Cascade Joins up to 6 boilers: Master boiler automatically recognizes linked boilers: Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation. Multiple Zone & Circulator Control Manages 2 separate reset curves for high and low temperature zones: Controls up to 4 circulators. Manages 2 space heating zones and 1 DHW zone without external zone control panel. Intelligent Troubleshooting Describes lockouts in plain english and suggests solutions: Stores last 8 errors. Records sensor readings for 24 hours. Next Generation Fire Tube Heat Exchanger High Water Content • Provides stable temperature control • Low sensitivity to water flow • Reduces short cycling • Adapts to large or small heating loads Unique Geometry • Designed for maximum reliability with low thermal stress • Improved water flow for maximum heat transfer • 439 Stainless Steel for corrosion resistance • Polypropylene condensate pan and flue resists corrosion Reliable Low Maintenance Design • Self cleaning design washes away combustion debris • 1 O year history of reliable performance • High performance burner design • Low pressure drop allows piping directly to the system prestige -Leader in Contractor Friendl~ Features Prestige Solo 110 Exploded View Polypropylene Flue and Condensate Pan Eliminates corrosion from condensate I Integrated Circulator & DHW Supply on Solo 11 O Model Simplifies piping and wiring Fold Down Control Panel Permits quick access to boiler internals Simplified Wiring Connections Wiring connections are well laid out and clearly marked. Fused high voltage connections makes trouble shooting easy The Widest Range of Venting and Termination Options Venting Terminations -2", 3", and 4" diameters depending on model -Traditional PVC/CPVC/PP/SS piping elbows -PVC,CPVC, SS and Polypropylene materials -Flush-mount PVC for twin pipes -Flexible Polypropylene for chimney chases -Flush-mount Stainless Steel for twin pipes -Concentric (399 only) or twin pipe -Single hole Concentric Termination for twin pipes -Extended vent lengths up to 100 feet -Horizontal Concentric Termination (399 only) -Common Vent for multiple boilers (399 only) -Horizontal and Vertical Common Vent Terminations (399 only) pres 1ge Performance Specifications , Model " , " *" Fuel / Input ' AFUE DOE NET Water . 0 Modulation Heating Capacity l=B=R Volume MBH MBH MBH Gal. Solo 60 Natural or Propane 16to60 95% 54 47 2.5 Solo 110 Natural Gas 30 to 110 95% 99 86 2.5 Solo 110 LP Propane Gas 25to97 95% 87 76 2.5 Solo 175 Natural or Propane 50 to 170 95% 154 134 4.6 Solo 250 Natural or Propane 65to245 95% 223 194 4.1 Solo 399 Natural or Propane 11210 399 95.1 o;.· 379 330 7 Connections / Dimensions / Data *Thermal Efficiency " Model Supply I Return'· Gas VenUAir Dimensions Weight Connections Connection Diameter D x W x H Lbs ~ /,~ /, " Solo60 1" 112· 3" 16"x 20" x 35 112" 95 Solo 110 1" 112" 3" 16"x 20" x 35 112" 106 Solo 175 1 1/4" 314" 3" 16"x 20" x 351/2" 131 Solo250 1 1/4" 3/4" 3" 16"x 20" x 351/2" 142 Solo 399 1 1/2" 1" 4" 20 314"x 24 314" x 37 112" 200 TriMax Control Features Standard Features • Large Graphic Interface • Stainless Steel FireTube Heat Exchanger • 60 Second Set-Up • EZ Access Terminal Strips with Individually • 6 Preset & Customizable Reset Curves Fused High VoltageTerminals • Standard ModBus Interface • Outdoor Reset Sensor • 2 Space Heating Call Inputs • Negative Pressure Regulated Gas Valve • Controls up to 4 Circulators • LP Conversion Kit • 0-10 VDC Modulation Input (All Models except Solo110) • Outdoor Reset • Cat IV Venting • Lockout Screens with Error Description and • NPT Piping Connections Troubleshooting recommendations: • Integrated Pressure Gauge Cascade Control for up to 6 Boilers • 30 psi Pressure Relief Valve -Auto-configure linked boilers -Simultaneous space heating & DHW capability • Automatic Air Vent -Full parallel modulation -Boiler rotation • Fold-down Control Panel for Easy Access • DHW Priority • Condensate Trap • Warm Weather Shutdown • 10 Year Non-Prorated Heat Exchanger • Low Water Cut Off Warranty • 2 Year Control & Blower Warranty Triangle Tube reserves the right to make product changes or improvements at any time without notice. Triangle Tube • One Triangle Lane • Blackwood NJ 08012 www.triangletube.com p 856.228.8881 f 856.228.3584 2011 -48 Prestige Solo Lit.-Revised 10/24/13 0 Triangle Construction Specifications SMART Series F H L M A--.i.a c J D A. Inner stainless steel tank B. Outer steel tank C. 2" Polyurethane insulation D. Boiler water connection E. Boiler water connection F. Hot water outlet G. Cold water inlet H. Auxiliary connection I. Thermostat control J. Plastic jacket K. Thermostat remote sensing bulb L. Air vent connection M. Electrical wiring plug Smart Series is tested in accordance with the standard (ANSl/UL-1 74) (CAN/CSA-C22.2 NO. 110-M90) and is certified by ETL. Superior Design .. Tank-in-Tank" Technolouv Superior Heat Exchange Surface Area The domestic storage tank is constructed of stainless steel and is surrounded by boiler water in the outer tank, resulting in a full "wrap around" heat exchanger. It's superior heat exchange surface (typically 1.5 to 2.5 times larger than a traditional coil) produces a larger volume of hot water in a short period of time. Thanks to this fast recovery, the storage capacity can be reduced, resulting in a reduced thermal loss. Stainless Steel Tank Construcdon The inner domestic storage tank is constructed of durable, corrosion resistant stainless steel. Opdmal lnsuladon SMART Series, is insulated with 2" of injected polyurethane foam, resulting in a stand by heat loss of less than 1°/Hr. Sen Cleaning I Sen -descaling The inner, domestic tank is suspended within the outer tank so it is free to expand and contract as the pressure varies during hot water draws. Moreover, its corrugations amplify the movement and prevents the lime build up on the heat exchanger; thus maintaining its performance during the SMART Series life span. And-Bacteria Growth I Maintenance Free The "Tank-in-Tank" design allows us to store domestic water at higher tempe- ratures preventing bacteria growth. Additionally, contructed of high quality stainless steel, SMART Series does not require a protective anode. Product Specincauons Model Dimension Height Boiler/Supply Domestic 3rd Domestic Domestic Heating Heat Empty No. Return lnleVOutlet Connection• Capacity Water Capacity Surface Weight (gal.} (gal.) (sq. ft.) (lbs) Smart 30 22" dia. 38" 1" 314" 314" 28 5 13 115 Smart 40 22" dia. 46" 1" 314" 314" 36 6 16 135 Smart 50 22" dia. 57" 1 1/411 314" 3/4" 46 8 20 165 Smart 60 22" dia. 66" 11/4" 3/4" 3/4" 56 8 24 190 Smart 80 26"dia. 61 " 11/2" 1112" 1112" 70 14 28 271 Smart 100 26" dia. 78" 1112" 1112" 11:!' 95 25 36 362 Smart 120 32" dia. 72" 2" 1112" 11/2" 119 43 42 479 (*)This fitting can be used as a return connection if circulated domestic water is required or can be used as a connection for the T&P Relief Valve. Performance Model Boiler Output 1st Hour Continuous Peak/Flow No. Btu/hr Recovery Flow Gal/10 min. (gal.) (gal.) Smart 30 87,000 140 115 40 Smart 40 112,000 180 150 50 Smart 50 140,000 220 185 65 Smart 60 270,000 410 360 100 Smart 80 300,000 460 400 125 Smart 100 337,000 525 450 150 Smart 120 420,000 650 560 190 How it works Smart Series operating cycle II Cold Start (pump off) Recovery Start (pump on) II Recovery Completed (pump off) Conditions: -200° boiler water supply -90° temperature rise II In Service (pump on) When the thermostat in the inner tank calls fo r heat, the boiler and circu- lator start. Boiler water is circulated around the outer tank and heats the domestic water in the inner tank. After transfer- ring its heat, boiler water is returned to the boiler to be re-heated. When the ther- mostat in the inner tank reaches its pre-set mark, the boiler and circulator shut off. Energy EHiciencv The Stainless Steel Indirect Fired Water Heater is heated by the hot water from your boiler. As your home is being heated, your domestic hot water is being heat- ed at the same time, thereby, consuming less fuel and conserving energy. Combine this with a recovery rate that is up to three times faster than conven- tional gas or electric water heaters, and The SMART Series Indirect Fired Water Heater heats more hot water with less fuel for the energy conscious consumer. Long Term Oependabilitv The average life span of a SMART Series Indirect Fired Water Heater exceeds 20 years! That is two or three times the average life of a conventional gas, oil or electric water heater. Installation IO Recirculation Loop 4 SMART Installation with Prestige Condensing Boiler Heating System Supply Heating System Return Cold Water Fi ll~"'-----'--. 7 Prestige - Boiler Return Boiler supply To dishwasher* 2 SMART Indirect Water Heater Optional 12" Heat Trap Loop (*)Optional devices may be required by local codes. 1. Temperature & Pressure 5. Flow Check Valve 9. Pressure Relief Valve Relief Valve 6. Backflow preventer or 10. Air Vent 2. Drain pressure reducing valve(*) 11 . Automatic Fill Valve 3. Shut -off Valves 7. Expansion Tank 4. Circulator 8. Mixing Valve Member of • 0 Tr1angleTube One Triangle Lane ·Blackwood NJ 08012 p 856.228. 8881 f 856.228.3584 www.triangletube.com Group 2009-8 Smart Lit. 6/8/rfJ