Loading...
HomeMy WebLinkAboutfireplace specs.pdf1 . . ~ r~pf 01c1 L1stmg and Code Approvals t 1 A. Appliance Certification MODELS: 6000C-IPI, 8000C-IPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Heater STANDARD: ANSI Z21.88-2014 •CSA 2.33-2014 This product is listed to ANSI standards for "Vented Gas Fireplace Heaters" and applicable sections of "Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles", and "Gas Fired Appliances for Use at High Altitudes". NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223. 1-latest edition in the U.S.A. and the CANICGA 8149 Installation Codes in Canada. NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations. B. Tempered Glass Specifications Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as defined by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectur- al Testing, Inc. Reports 02-31919.01 and 02-31917.01). This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 "Certification and labeling requirements" which refers to 15 U.S. Code (USC) 2063 stating " Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered." Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. C. BTU Specifications Models Maximum Minimum Orifice Input Input Size (U.S. or Canada) BTU/h BTU/h (OMS) us 30,000 16,000 37 (0-2000 FT) 6000C-IPI (NG) CANADA (2000-4500 FT) 27,000 14,400 38 us 29,000 17,000 52 6000C-IPILP (0-2000 FT) CANADA 26,100 15,300 53 (2000-4500 FT) us 35,000 19,000 33 (0-2000 FT) 8000C-IPI (NG) CANADA (2000-4500 FT) 31,500 17,100 34 us 34,000 17,000 50 8000C-IPILP (0-2000 FT) CANADA 30,600 15,300 51 (2000-4500 FT) D. High Altitude Installations NOTICE: ff the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When installing above 2000 feet elevation: • In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet. • In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Check with your local gas utility to determine proper orifice size. ~~Non-Combustible Materials Specification Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof. Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 °C shall be considered non-combustible materials. F. Combustible Materials Specification Materials made of or surfaced with wood , compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials. G. Electrical Codes NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSl/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AD • 2/16 7 Note: The following requirements re ference va ri ous Massachusetts and national codes not contained in this document. H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above fin ished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied: Installation of Carbon Monoxide Detectors At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling , bu ilding or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of th irty (30) days to comply with the above requirements; provided , however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. Signage A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) in. in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS". Inspection The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: • The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and • Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: • Detailed instructions for the installation of the venting system design or the venting system components; and • A complete parts list for the venting system design or venting system. Gas Equipment Venting System NQI Provided When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer: • The referenced "special venting system" instructions shall be included with the appliance or equipment in- stallation instructions; and • The "special venting systems" shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions. A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. See Gas Connection section for additional Common- wealth of Massachusetts requirements. 8 Heat & Glo • 6000C-IPI, BOOOC-IPI • 2164-900 Rev. AD • 2/16