Loading...
HomeMy WebLinkAboutPEC17-0006_town council approved plans_1514396629.pdfDRAWING ABBREVIATIONS GENERAL NOTES LEGEND CONCRETE/ PRECAST CONCRETE SOIL SAND, EIFS FINISH COAT, OR CEMENT PLASTER BRICK CMU PAVERS CELLULOSE INSULATION FIBERGLASS SOUND BATT INSULATION POLYISOCYANURATE INSULATION BOARD CLOSED CELL POLYURETHANE SPRAY INSULATION GYPSUM BOARD EXTERIOR GYPSUM SHEATHING MATERIALS ROOM NAME XXXXX X X 1 A0.X X X A3ROOM NAME/NUMBER EXISTING COLUMN CENTERLINE COLUMN CENTERLINE ACCESSORY DEMOLITION NUMBERED NOTES BUILDING WALL SECTION ELEVATION SECTION DETAIL PLAN, BLOW-UP DETAIL PARTITION TYPE NEW WALL EXISTING WALL 1 HOUR FIRE WALL 2 HOUR FIRE WALL 2 HOUR SHAFT WALL DRAWING SYMBOLS CEILING SYMBOLS BUILDING EXPANSION JOINT GYP BD CEILING SUPPLY AIR RETURN AIR ACCESS PANEL FLUORESCENT LIGHT WALL MOUNTED FLUORESCENT FIXTURE EXIT SIGNS - HATCH INDICATES EXIT TEXT AND ARROW INDICATES DIRECTION SMOKE DETECTOR WALL WASHER PENDANT TYPE LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE DOWNLIGHT STRIP LIGHT SPEAKER S D 01 +9'-0" CEILING HEIGHT S EXHAUST AIR A0.X X 01 SUSPENDED LIGHT SUSPENDED FLUORESCENT LIGHT CHANDELIER PROJECTOR A0.X X 01 A0.X X AB ANCHOR BOLT ACT ACOUSTICAL TILE CEILING AFF ABOVE FINISH FLOOR ALUM ALUMINUM AP ACCESS PANEL APPROX APPROXIMATE ARCH ARCHITECTURE ASSOC ASSOCIATED BD BOARD BLDG BUILDING BLK BLOCK BO BOTTOM OF BOT BOTTOM BRG BEARING BSMT BASEMENT CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS COVR COVER CP CONCRETE PAVER CPT CARPET CT CERAMIC TILE CTR CENTER DEC DETENTION EQUIPMENT CONTRACTOR DET DETENTION DEMO DEMOLITION DIA DIAMETER DIM DIMENSION DF DRINKING FOUNTAIN DGB DETENTION GRAB BAR DR DOOR DWG DRAWING EA EACH EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR EQ EQUAL EQUIP EQUIPMENT ER EPOXY RESIN EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FE FIRE EXTINGUISHER FF EL FINISH FLOOR ELEVATION FIN FINISH FRT FIRE RESISTANT TREATED FLR FLOOR FS FOOD SERVICE FT FOOT FTG FOOTING FUT FUTURE GA GUAGE GC GENERAL CONTRACTOR GL GLASS GR GRADE GYP BD GYPSUM BOARD HC HOLLOW CORE HT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL INT INTERIOR INSUL INSULTATION JAN JANITOR JST JOIST LAV LAVATORY MAX MAXIMUM MECH MECHANICAL 1. DO NOT SCALE DRAWINGS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. SPECIFICATIONS GOVERN ALL CONTRACT DOCUMENTS. 2. CONTRACTOR TO ISSUE COMPLETE SET OF CONTRACT DOCUMENTS TO EACH OF THE SUBCONTRACTORS FOR COORDINATION OF THEIR WORK AND DESCRIPTION OF SCOPE - ALL DRAWINGS MUST BE REVIEWED BY EACH TRADE AND IF DISCREPANCIES ARE FOUND AN RFI IS TO BE SUBMITTED TO THE ARCHITECT. 3. THEIR SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR EQUAL" IS USED THE ARCHITECT SHALL DETERMINE EQUALITY BASED ON INFORMATION SUBMITTED BY THE CONTRACTOR VIA A DOCUMENTED SUBSTITUTION REQUEST. 4. REFER TO STRUCTURAL DRAWINGS FOR ALL REINFORCING AND STRUCTURAL INFORMATION. 5. ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND NON- STRUCTURAL SYSTEMS, COMPONENTS AND ELEMENTS PERMANENTLY ATTACHED TO STRUCTURES, INCLUDING SUPPORTING STRUCTURES AND ATTACHMENTS, AND NON- BUILDING STRUCTURES THAT ARE SUPPORTED BY OTHER STRUCTURES SHALL MEET THE REQUIREMENTS PER IBC 2015, CHAPTER 16 AND ASCE 7-02, SECTION 9.6 COORDINATE COMPONENT DESIGN WITH ARCHITECT AND MECHANICAL ENGINEER OF RECORD. 6. WHERE MANUFACTURER'S RECOMMENDED DETAILS DIFFER FROM THE CONTRACT DOCUMENTS, GENERAL CONTRACTOR TO IDENTIFY AND SUBMIT RFI TO ARCHITECT FOR CLARIFICATION. 7. ALL RESTROOM INTERIOR WALL PARTITIONS TO BE INSTALLED WITH SOUND BATT-INSULATION UNLESS NOTED OTHERWISE MEM MEMBRANE MNFR MANUFACTURER MIN MINIMUM MR MOISTURE RESISTANT MTL METAL NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OA OVERALL OAM OVERALL MASONRY OC ON CENTER OH OVERHEAD ORD OVERFLOW ROOF DRAIN OS OVERFLOW SCUPPER OPG OPENING OPOI OWNER PROVIDED OWNER INSTALLED OPCI OWNER PROVIDED CONTRACTOR INSTALLED PC PRECAST PF PREFINISHED PJ PANEL JOINT PL PLATE PLAM PLASTIC LAMINATE PLMG PLUMBING PNL PANEL PT PRESSURE TREATED PTD PAPER TOWEL DISPENSER REINF REINFORCED REQ REQUIRED REV REVISED RD ROOF DRAIN RM ROOM RO ROUGH OPENING SAP SECURE PANEL ACCESS SC SEALED CONCRETE SCHED SCHEDULED SEC SECURITY SECT SECTION SHT SHEET SHWR SHOWER SK SINK SPEC SPECIFICATIONS SS STAINLESS STEEL STL STEEL STIFF STIFFENER STRUCT STRUCTURAL T&G TONGUE AND GROOVE TO TOP OF TOF TOP OF FOOTING TPH TOILET PAPER HOLDER TS TUBE STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VAR VARIES VB VAPOR BARRIER VCT VINYL COMPOSITE TILE VERT VERTICAL VIF VERIFY IN FIELD VT VINYL TILE VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WITH WC WATER CLOSET WD WOOD WDW WINDOW WP WATERPROOF WT WALL TYPE WWF WELDED WIRE FABRIC PROJECT TEAM LANDSCAPE MACDESIGN P.O. BOX 6446 AVON, COLORADO 81620 MEP SGM 118 W SIXTH ST, SUITE 200 GLEENWOOD SPRINGS, COLORADO 81601 970-384-9032 CIVIL ALPINE ENGINEERING, INC. 34510 HIGHWAY 6, UNIT A-9 EDWARDS, COLORADO 81632 ARCHITECTURE 359 DESIGN, LLC 3630 OSAGE STREET DENVER, COLORADO 80211 INTERIORS OWNER GORE CREEK LLC 285 BRIDGE STREET VAIL, COLORADO 81657 952-210-0095 GENERAL CONTRACTOR SHAW CONSTRUCTION 300 KALAMATH ST, DENVER 80223 720-582-3535 STRUCTURAL MONROE AND NEWELL ENGINEERS, INC. 1400 GLENARM PLACE, SUITE 101 DENVER, COLORADO 80202 FIRE & LIFE SAFETY SHANER LIFE SAFETY P.O. BOX 1073 FRISCO, COLORADO 80443 WS-MAS1 EXTERIOR ENCLOSURE IDENTIFIER OCG COLORADO 970-471-4192 I-70 PROJECT SITE 1"=400'PROJECT LOCATION PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A0.0 SDD COVER 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET VAIL MOUNTAIN VIEW - PHASE II 434 SOUTH FRONTAGE RD EAST VAIL, COLORADO INDEX OF DRAWINGS SDD SHEET NUMBER SHEET NAME A0.0 SDD COVER C1.01_ GRADING C1.02 PROPOSED UTILITY PLAN C1.03 DETAILS C1.04 FIRE STAGING & TURNING MOVEMENT SIMULATION L1.1 LANDSCAPE PLAN A1.00 PLAN-ARCHITECTURAL SITE A2.0.01 GARAGE LEVEL 1 A2.0.02 GARAGE LEVEL 2 A2.0.03 GARAGE LEVEL 3 A2.01 OVERALL LEVEL 1 (8226'-0") A2.02 OVERALL LEVEL 2 (8236'-6") A2.03 OVERALL LEVEL 3 (8247'-0") A2.04 OVERALL LEVEL 4 ((8258'-0") A2.05 OVERALL DORMER LEVEL (8269'-0") A2.06 GRFA PLANS - Garage A2.07 GRFA PLANS- Building A2.08 GRFA PLANS - Building A2.10 SITE COVERAGE A2.10B SITE COVERAGE A2.11 LANDSCAPE COVERAGE A2.12 ROOF HEIGHT A2.13 HISTORIC GRADE MAP A4.00 3D MASSING A4.02 OVERALL BUILDING ELEVATIONS A4.03 OVERALL BUILDING ELEVATIONS A4.04 OVERALL BUILDING ELEVATIONS A4.05 OVERALL BUILDING ELEVATIONS A9.11 LIGHTING PLAN A9.16 SITE SECTION VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET No. Description Date 9-14-17 12/19/2017 12:00:00 AM                     ߰    !     "      # $  % &'  ߰    '   # %   #   (      ߰  (      ߰     $߰   ')$*        #       +, -,./0+, -,./0   ')$*    $   (   '߰%)' '߰) '߰%)1 '߰߰) '߰)               ߰                                                       ߰  !           "      # #           # # $ %                  & '    ( #   )   # ) #    #      *                + #                          #           &               ,        #   !     #                      - .    ,  #     $  %  #   )      # #%  ' /     #  (      )   ##     ,    !'!     * ($!!(      !      *'$(#       (   +(           09/14/2017 12/19/2017 12:00:00 AM 22 8222 8214 8212 8210 8208 8216 8218 8220 8214 8212 8210 8216 8218 8220 8206 8206 8208 8204 8202 8180 8204 8202 8200 8190 MOUNTAIN VIEW PHASE I TYROLEAN 8220 8 2 1 8 8216 8 2 1 4 8 2 1 2 8210 8 2 0 8 8206 8204 8202 8200 8 2 0 2 8190 8 1 8 0 8 2 0 4 8206 8208 8210 8212 8214 8216 8218 8220 8222 RIDGE: PARAPET TO SCREEN MECHANICAL EQUIPMENT 23 : HVAC EQUIPMENT RE. MECHANICAL 23 : HVAC EQUIPMENT RE. MECHANICAL PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.13 HISTORIC GRADE MAP 17021VAIL MOUNTAIN VIEWPHASE II08/15/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1" = 10'-0"1 HISTORIC GRADE MAP 0' 5' 20'10' No. Description Date VMVR Development Plan Set 08/15/2017 PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM UP UP DN DN 1875 SF UNIT 401 455 SF UNIT 402 - LO 1354 SF UNIT 402 1228 SF UNIT 403 1257 SF UNIT 404 1265 SF UNIT 405 363 SF UNIT 406 - LO-2 1336 SF UNIT 406 367 SF UNIT 401 - LO COMMON STORAGE EHU FOR SALE Hallway HOTEL LOCK OFF 423 SF UNIT 406 - LO 194 SF UNIT 402 - LO 2 253 SF UNIT 404 - LO 264 SF UNIT 405 - LO272 SF UNIT 403 - LO 747 SF UNIT 401 - DORMER 968 SF UNIT 405 - DORMER 821 SF UNIT 406 - DORMER 1048 SF UNIT 402 - DORMER 887 SF UNIT 404 - DORMER 1043 SF UNIT 403 - DORMER COMMON STORAGE EHU FOR SALE Hallway HOTEL LOCK OFF DECK DECK DECK DECK DECKDECK DECK DECK PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.08 GRFA PLANS - Building 17021VAIL MOUNTAIN VIEWPHASE II08/15/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/16" = 1'-0"1 Level 4 1/16" = 1'-0"2 Dormer Level Area Schedule (GRFA) Level 4 TYPE UNIT Area Level 4 FOR SALE UNIT 401 1875 SF FOR SALE UNIT 402 1354 SF FOR SALE UNIT 403 1228 SF FOR SALE UNIT 404 1257 SF FOR SALE UNIT 405 1265 SF FOR SALE UNIT 406 1336 SF FOR SALE: 6 8315 SF LOCK OFF UNIT 401 - LO 367 SF LOCK OFF UNIT 402 - LO 455 SF LOCK OFF UNIT 402 - LO 2 194 SF LOCK OFF UNIT 403 - LO 272 SF LOCK OFF UNIT 404 - LO 253 SF LOCK OFF UNIT 405 - LO 264 SF LOCK OFF UNIT 406 - LO 423 SF LOCK OFF UNIT 406 - LO-2 363 SF LOCK OFF: 8 2591 SF Grand total: 14 10905 SF Area Schedule (GRFA) Dormer Level TYPE UNIT Area Dormer Level FOR SALE UNIT 401 - DORMER 747 SF FOR SALE UNIT 402 - DORMER 1048 SF FOR SALE UNIT 403 - DORMER 1043 SF FOR SALE UNIT 404 - DORMER 887 SF FOR SALE UNIT 405 - DORMER 968 SF FOR SALE UNIT 406 - DORMER 821 SF FOR SALE: 6 5514 SF 0' 8' 32'16' 0' 8' 32'16' No. Description Date VMVR Development Plan Set 08/15/2017 12/19/2017 12:00:00 AM UPUP 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 8' - 0" 11' - 9" 2 A5.00 8' - 0"11' - 9" 9' - 2" 11' - 9" 10 6 .87 ° 106. 87 ° 1 A5.02 8.5 8.5 21 22 23 24 25 26 27 28 29 30 31 32 33 20 1817 19 14 13 12 11 10 9 8 7 6 5 4 2 1 3 TYP 9' - 0" 7' - 2 3/8"TYP18' - 0"DRIVE AISLE24' - 0"TYP18' - 0"TYP 9' - 0" 9' - 0" 5' - 0" TRASH / RECYCLE MECH. C C 3 A5.02 1 A5.01 1 A5.00 A8.02 4 A8.01 2 A8.03 1 A8.20 1 A8.21 1 A8.22 3 3 A5.11 1 A5.11 2 A5.11 GARAGE LEVEL 1 PHASE II OWNER PARKING 4 A5.10 EQ EQ EQ4' - 8" EQ EQG112 G113 G114 G120G119 G118 G104 G106 G108G109G107 G105G110 G102S-301 S-302 S-303 S-304 S-305 S-306 G111S-405 S-406S-404 S-402 G101 G103 14' - 0 1/8" 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 21' - 8" 6' - 6" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" 15 16 6% ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.0.01 GARAGE LEVEL 1 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 Garage Level 1 0' 4' 16' 8' No. Description Date KEYNOTE LEGEND 12/19/2017 12:00:00 AM DN UPDN UP UP 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 98.3 6 ° 2 A5.02 4 A5.02 2 A5.00 135.00° 1 A5.02 01 x1.001 02 x1.001 8.5 8.5 19 18 FIRE SPRINKLER ROOM TYP18' - 0"DRIVE AISLE24' - 0"TYP18' - 0"TYP 9' - 0" C C 3 A5.02 1 A5.01 1 A5.00 A8.02 7 A8.01 3 A8.03 2 A8.20 2 A8.21 2 A8.22 4 3 A5.11 1 A5.11 2 A5.11 GARAGE LEVEL 2 GARAGE LEVEL 2 4 A5.10 S-401 S-403 OPEN MECH G201G202G207G203 G205 G204 G206FS-CONC-3 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" 28' - 2" 14' - 0 1/8" 30 31 32 33 1 2 6 13 14 15 21 9 10 11 12 3 4 5 FS-CONC-3 20 16 17 7 8 ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.0.02 GARAGE LEVEL 2 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 Garage Level 2 0' 4' 16'8' No. Description Date KEYNOTE LEGEND 12/19/2017 12:00:00 AM UPDN UP DN DN 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 2 A5.00 F.A.C.P. SKI LOCKERS 1 A5.02 8.5 8.5 32' - 0" 25' - 11 3/8" TRASH/ RECYCLING ELEVATOR LOBBY RAMPOVERHEAD DOOR20' - 0"16 17 18 19 20 21 22 23 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 1 C C 4' - 0"3' - 0"4"1' - 0" ELECTRICAL METER ROOM PHASE II 6' - 0" 10"3 A5.02 1 A5.01 1 A5.00 A8.02 8 A8.01 4 A8.03 3 A8.20 3 A8.21 3 A8.22 5 3 A5.11 1 A5.11 2 A5.11 TYP 9' - 0" TYP 5' - 0" TYP 9' - 0" TYP 9' - 0" TYP 5' - 0" 8215' - 2 1/2"HOTEL & RESIDENTIAL PARKING GARAGE LEVEL 3 GARAGE LV 3 4 A5.10 BOILER ROOM BOILER ROOM G301G302G305G303 G304 G306 G308 G309 G307 G312 G310 G311 G313G31414' - 0 1/8" 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 21' - 8" 6' - 6" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.0.03 GARAGE LEVEL 3 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 Garage Level 3 0' 4' 16'8' No. Description Date KEYNOTE LEGEND 12/19/2017 12:00:00 AM DN UPUP DN DN UP DN REF. REF. WHREF. WH 1 1 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 2 A5.00 LANDSCAPE ABOVE RAMP EXTERIOR SITE STAIRS 14 RISERS EXTERIOR SITE STAIRS 11 RISERS FIRE HYDRANT LIVING-C 1 A5.02 HEATED PAVERSPROPOSED F.D.C. CHECK IN 102 RESTROOM 117 BEDROOM 1-A LIVING-A MASTER CLOSET-A MASTER BATH-A CLOSET-A BATH-A KITCHEN-A MASTER BEDROOM-C CLOSET MASTER CLOSET-C LAUNDRY-D CLOSET-D MASTER BATH-D MASTER BEDROOM-DBEDROOM 1-DLIVING-D KITCHEN-D BATH-D CLOSET KITCHEN-E MASTER BATH-E CLOSET-E CLOSET-E MASTER BEDROOM-E BEDROOM 1-E BATH-E CLOSET-F BATH-F BEDROOM 1-F CLOSET-ELIVING-F DINING-F KITCHEN-F MASTER BATH-C MASTER BEDROOM-A 101CLOBBY 101 VEST. 100 102109CORRIDOR 111 112A CORRIDOR 115 113ACORRIDOR 114114 CLO 8.5 8.5 LOADING SPACE12' X 35'CURRENT F.D.C. OUTDOOR DECK C C A8.01 1 3 A5.02 1 A5.01 1 A5.00 A8.02 1 A8.03 4 A8.20 4 A8.21 4 A8.22 6 3 A5.11 1 A5.11 2 A5.11 224' - 8" LIVING-E 4 A5.10 PLANTER 113B 112C 103 STORAGE 109 CORRIDOR 110 104113CRAMP 8.3% RA M P 8.3%101A112B11' - 3 1/4" 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 21' - 9 5/8" 6' - 4 3/8" 26' - 2" 18' - 4" 11' - 2"17'26'1% DN 2% DN1% DN 101B17' - 6"26' - 0" 17' - 6" 23' - 0" 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN C64 C64 C64 C64 C64 C64 C64 C64 5' TALL PRIVACY WALL4'FROM PARCEL LINE24'FROM PARCEL LINE11'KITCHEN-C BATH-B MECH-B LIVING-B KITCHEN-B BEDROOM-B MASTER BATH-G MASTER CLOSET-G MASTER BEDROOM-G LIVING-G BEDROOM-G BATH-G CLOSET-G CLOSET-G KITCHEN-G MASTER BATH-H MASTER CLOSET-H MASTER BEDROOM-H LIVING-H BEDROOM-H BATH-H CLOSET-H CLOSET-H KITCHEN-H BEDROOM-J BATH-J CLOSET-J DINING-J LIVING-J KITCHEN-J LAUNDRY-J MECH-J BUFFER6' - 0"25' - 0"10' - 0"116MASTER CLOSET-E LAUNDRY-AARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.01 OVERALL LEVEL 1 (8226'-0") 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0" 1 Level 1 0' 4' 16' 8' No. Description Date KEYNOTE LEGEND C64 22 : FLOOR DRAIN, FLAT METAL DRAIN COVER, RE: PLUMBING FOR DRAIN ROUTING 12/19/2017 12:00:00 AM DN DN DN WH WHREF. REF. 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 2 A5.00 1 A5.02 LIVING-K KITCHEN-K MASTER BEDROOM-KBEDROOM 1-K CLOSET-K BATH-K LAUNDRY-K STORAGE-K CLOSET-K MASTER BATH-K MASTER CLOSET-K KITCHEN-N LIVING-N MASTER BEDROOM-N MASTER BATH-N TOILET-N MASTER CLOSET-N CLOSET-N LAUNDRY-N BATH-N BEDROOM 1-N CORRIDOR 210 211B8.5 2 0 ' 1 5 'C C 3 A5.02 1 A5.01 1 A5.00 A8.02 2 A8.01 5 A8.03 5A8.20 5 A8.21 5 A8.22 7 3 A5.11 1 A5.11 2 A5.11 4 A5.10 CIRCULATION-K UNIT K 211D219CLO. 219 210211C 211A 211E 1% DN 1% DN 1% DN 1% DN 1% DN 11' - 3 1/4" 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" C64 C64 C64 C64 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN C64 C64 1% DN 5% DN1% DN FROM PARCEL LINE23'FROM PARCEL LINE24'FROM PARCEL LINE11'LO MASTER BATH-206 BEDROOM 1-206 BATH 1-206 BATH 2-206 MASTER BATH-205 TOILET MASTER BEDROOM-205 LOCK-OFF BEDROOM 1-205 KITCHEN-205 DINING-205 LIVING-305 LOCK-OFF BEDROOM 2-205 LO BATH 2-205 MASTER CLOSET-205 ENTRY-205 POWDER 205 LIVING-304 MASTER BEDROOM-204 MECH-204 MASTER CLOSET-204 POWDER-204 LO BATH-204 LOCK OFF MASTER BEDROOM-206 POWDER-206 CLO. LAUNDRY-206 MECH-206 KITCHEN-206 DINING-206 LIVING-206 LO BATH 1-205 MASTER BATH-204 LOCK-OFF BEDROOM-204 DINING-204 KITCHEN-204 ENTRY-204 MECH-205 BEDROOM 2-206 BATH-L MECH-L LIVING-L KITCHEN-L BEDROOM-L BEDROOM-M BATH-M MECH-M CLOSET-M LIVING-M KITCHEN-M CLOSET-O BATH-O BEDROOM-O LIVING-O LAUNDRY-O MECH-O DINING-O KITCHEN-O MASTER BATH-P MASTER CLOSET-P MASTER BEDROOM-P CLOSET-P BATH-P BEDROOM-P KITCHEN-P LIVING-P ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.02 OVERALL LEVEL 2 (8236'-6") 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 Level 2 0' 4' 16' 8' No. Description Date KEYNOTE LEGEND C64 22 : FLOOR DRAIN, FLAT METAL DRAIN COVER, RE: PLUMBING FOR DRAIN ROUTING 12/19/2017 12:00:00 AM UP DN UP DN UP DN 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 2 A5.00 ELEV.ELEV.ELEV. KITCHEN-301 DINING-301 LIVING-301 BEDROOM 1-301 LOCK OFF-BEDROOM-301 MASTER BEDROOM-301 MASTER BATH-301 TOILET-301 CLO MASTER CLOSET-301 LIVING-303 DINING-303 KITCHEN-303 MASTER BEDROOM-303 TOILET MASTER CLOSET-303 BATH LO-303 LOCK OFF BEDROOM-303 MECH-303 LIVING-304 DINING-304 KITCHEN-304 MASTER BATH-305 TOILET MASTER BEDROOM-304 MASTER BEDROOM-305 LOCK OFF BEDROOM-304 LOCK-OFF BEDROOM 1-305 MECH-304 BATH-305 KITCHEN-305 DINING-305 LIVING-305MECH-305LOCK-OFF BEDROOM 2-305 BATH-305 BEDROOM 2-306 BEDROOM 1-306 MASTER CLOSET-305MASTER CLOSET-304 BATH-302 TOILET KITCHEN-302 ENTRY-302 POWDER-302 MASTER BATH-302 TOILET MASTER CLOSET-302 CLO MASTER BEDROOM-302 LIVING-302 DINING-302 CLOSET-302 LOCK OFF BEDROOM 1-302 ENTRY-303 ENTRY-305 1 A5.02 MASTER BATH-304 LOCK OFF BEDROOM 2-302 CLOSET POWDER-304 BATH LO-304 BATH-302 MECH-302 CLOSET MASTER BATH-303 CORRIDOR 311311A 312A313A8.5 8.5 MECH-301 BATH-301 CLOSET POWDER C C ENTRY-304 BATH 1-306 BATH 2-306 KITCHEN-306 DINING-306 LIVING-306 4' - 6"3 A5.02 1 A5.01 1 A5.00 A8.02 3A8.01 6 A8.03 6 A8.20 6 A8.21 6 A8.22 8 3 A5.11 1 A5.11 2 A5.11 POWDER-303 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 4 A5.10 313312311CORRIDOR 312 CORRIDOR 313 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 22' - 1 5/8" 6' - 0 3/8" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" 14' - 0 1/8" 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN1% DN 1% DN 1% DN 1%1% DN1% DN 1% DN 1% DN C64 C64 C64 1% DN 1% DN 1% DN C64 C64 1% DN 1% DN 1% DN2% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1%1% DN 1%2 %2%4%C64 C64 C64 C64 C64 C64 C64 3%C64C64 C64 FROM PARCEL LINE23'FROM PARCEL LINE25'FROM PARCEL LINE10'FROM PARCEL LINE27'MASTER BATH-306POWDER-306 CLO. LOCK-OFF MASTER BEDROOM-306 ENTRY-306 ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.03 OVERALL LEVEL 3 (8247'-0") 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0" 1 Level 3 0' 4' 16' 8' No. Description Date KEYNOTE LEGEND C64 22 : FLOOR DRAIN, FLAT METAL DRAIN COVER, RE: PLUMBING FOR DRAIN ROUTING 12/19/2017 12:00:00 AM UP UP DN DN DN UP UP 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 2 A5.00 DINING-406 KITCHEN-406 BEDROOM 2-406 LOCK OFF BEDROOM 1-406 LOCK OFF BEDROOM 2-406 LIVING-405 DINING-405 KITCHEN-405 MASTER BEDROOM-405 MASTER BEDROOM-404 MASTER BATH-405 LIVING-404 DINING-404 KITCHEN-404 LOCK OFF BEDROOM-404 LOCK OFF BEDROOM 1-405 MECH-405 BATH LO-404 MASTER BEDROOM 1-403 LIVING-403 DINING-403 KITCHEN-403 MASTER BATH-403 LOCK OFF BEDROOM 1-403 MECH-403 BATH LO1-403 MASTER BEDROOM-401LIVING-401 DINING-401 KITCHEN-401 BEDROOM 1-401 LOCK OFF BEDROOM-401 MASTER BATH-401 LOCK OFF BEDROOM 1-402 CLOSET-402 BATH LO1-402 ENTRY LO-402 KITCHEN-402 DINING-402 LIVING-402 MASTER BEDROOM-402 MASTER CLOSET-402 CLOSET TOILET POWDER-402 1 A5.02 17' - 6"26' - 0" 17' - 6" 23' - 0" MASTER CLOSET-403 CLOSET TOILET MASTER CLOSET-401 BATH-401 BATH LO2-402 LAUNDRY LOCK OFF BEDROOM 2-402 CLOSET TOILET POWDER-401 ELEV. ELEV. ELEV.MECHMASTER CLOSET-404 MASTER CLOSET-405 TOILET TOILET411A412A 413ACORRIDOR 411 411BENTRY-406 8.5 8.5 CLOSET CLOSET BEDROOM 1-406 C C ENTRY-401 ENTRY-403 ENTRY-404 ENTRY-405 3 A5.02 1 A5.01 1 A5.00 A8.02 5 ENTRY-402 A8.01 8 A8.03 7 A8.20 7 A8.21 7 A8.22 9 MECH-402 MECH-401 3 A5.11 1 A5.11 2 A5.11 TOILET BATH LO2-406 CLOSET MECH-406 CLO. MASTER BATH-402 BATH 1-406 BATH 2-406 BATH LO1-406 POWDER-406 POWDER-403 CLOSET CLOSETCLO. 4 A5.10 412B413B CORRIDOR 412 CORRIDOR 413 14' - 0 1/8" 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 21' - 9 3/8" 6' - 4 5/8" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" 12 A7.02 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN1% DN 1% DN 1% DN1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 2% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 1% DN 2%2%3% C64 C64 C64 C64 C64 C64 C64 C64 C64 C64C64 C64C64C64 C64 3%1%1%1%1%C64 C64 FROM PARCEL LINE23'FROM PARCEL LINE25'FROM PARCEL LINE 10'FROM PARCEL LINE27'4' - 11 1/2" ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.04 OVERALL LEVEL 4 ((8258'-0") 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0" 1 Level 4 0' 4' 16' 8' No. Description Date KEYNOTE LEGEND C64 22 : FLOOR DRAIN, FLAT METAL DRAIN COVER, RE: PLUMBING FOR DRAIN ROUTING 12/19/2017 12:00:00 AM DN DN DN 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 A A B B D D E E 9 9 0 0 2 A5.02 4 A5.02 DORMER LIVING-402 REC ROOM-402 DECK-402 POWDER-402 MASTER CLO-402 GUEST MASTER BEDROOM-402 GUEST BATH REC-401 DECK-401 DORMER LIVING-403 BATH-403 BATH-404 BEDROOM 2-403 VANITY-405 BATH-405 BEDROOM-404 BEDROOM-405 DORMER LIVING-404 DECK-404 CLOSET 1 A5.02 DECK-402 DECK-403 FSD-CP-1FSD-CP-1 FSD-CP-1 FSD-CP-1 FSD-CP-1 FSD-CP-1 FSD-CP-1 8.5 8.5 SETBA CK20' MASTER BEDROOM-406 MASTER CLOSET-406 MASTER BATH-406TOILET DECK-406 DECK-405 LIVING-405 C C GUEST MASTER-401 GUEST MASTER-404 GUEST BATH-404 3 A5.02 1 A5.01 1 A5.00 CLOSET 2-403 3 A5.11 1 A5.11 2 A5.11 GUEST MASTER-405 CLOSET GUEST BATH-405 GUEST MASTER-403 OPEN TO BELOW 4 A5.10 FSD-CP-1FSD-CP-1 14' - 0 1/8" 16' - 8" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 21' - 8" 6' - 6" 26' - 2" 18' - 4" 11' - 2"17' - 6"26' - 0" 17' - 6" 23' - 0" ROOF ACCESS 1% DN1% DN R-1A8.02 9 1% DN1% DN1% DN1% DN1% DN 1% DN1% DN1% DN1% DN1% DN1% DN 1% DN1% DN1%1% DN1% DN 1% DN 1% DN1% DN1% DN 1% DN 1% DN1% DN 1% DNC64 C64 C42 C64 C64 C64 C64 C64 1% DN1% DN 1% DN1% DN1% DN 1% DN 1 % DN 2% DN 1% DN 1% DN 1% DN C64 C64 C64 C64 C70 ARCHITECTURAL NOTES 1. REFER TO SHEET A0.01, A0.02 FOR BLDG ENCLOSURE ASSEMBLIES, PARTITIONS TYPES A1.10. 2. ALL ROOFS TO SLOPE MINIMUM 1/4" OVER 1' - 0". 3. ELECTRICAL METER AND SERVICE TO BE MOUNTED AT GARAGE LEVEL ?, COORDINATE METER AND PANEL LOCATION WITH OWNER. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DESIGN BUILD SECURITY SYSTEM, CORD. WITH OWNER. 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL BEDROOMS, AND OUTSIDE OF ALL BEDROOMS AND ON EACH FLOOR AS REQUIRED. 6. MECHANICAL SYSTEM SHALL. 7. WATER PIPES RUNNING NEXT TO OR WITHIN EXTERIOR WALLS TO BE INSULATED W/ 2" MIN CLOSED CELL INSULATION. 8. ALL DIMENSIONS ARE TO FACE OF STUD, GRID LINE, FACE OF MASONRY OR CONCRETE, U.N.O. 9. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. 10. FURNITURE IS NOT IN CONTRACT, U.N.O. AND SHOWN FOR DIAGRAMATIC PURPOSES. 11. CONTRACTOR SHALL COORDINATE ALL MEANS, METHODS, SEQUENCES PROCEDURES AND SCHEDULES OF ALL CONSTRUCTION ACTIVITIES AND OPERATIONS FOR THE CONSTRUCTION OF THE PROJECT. 12. CONTRACTOR RESPONSIBLE FOR OBTAINING AND COMPLYING WITH ALL PERMITS. 13. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL MANUFACTURERS RECOMMENDATIONS FOR STORAGE, PREPARATION, FABRICATION, INSTALLATION AND CURING OF MATERIALS AND SYSTEMS. 14. DIMENSION FROM EDGE OF DOOR FRAME (HINGE SIDE) TO FACE OF ADJACENT PERPENDICULAR WALL TO BE 4" U.N.O. 15. PROVIDE BLOCKING FOR WALL MOUNTED ELECTRICAL FIXTURES, BATHROOM ACCESSORIES, HANDRAILS, CHAIR RAILS, WAINSCOTING, ARTWORK, ETC. 16. RE: DOOR SCHEDULE AND DOOR HARDWARE SETS. 17. REFER TO BUILDING PLANS, RCP, EXTERIOR ELEVATIONS FOR WINDOW LOCATION AND TYPE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.05 OVERALL DORMER LEVEL (8269'-0") 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0" 1 Dormer Level 0' 4' 16'8' No. Description Date KEYNOTE LEGEND C42 10 3100 : FIREPLACE GAS RE: APPLIANCE PACKAGE C64 22 : FLOOR DRAIN, FLAT METAL DRAIN COVER, RE: PLUMBING FOR DRAIN ROUTING C70 10 3100 : FIREPIT GAS RE: APPLIANCE PACKAGE 12/19/2017 12:00:00 AM UPUP DN UPDN UP UP UPDN UPDN DN 33 PARKING SPACES 21 22 23 24 25 26 27 28 29 30 31 32 33 20 1817 19 14 1312 11 10 9 8 7 6 5 4 2 1 3 77 SF STR. 7 77 SF STR. 8 77 SF STR. 9 369 SF STR. 10MECH.TRASH / RECYCLE 15 16 COMPACT COMMON STORAGE EHU FOR SALE LOCK OFF FIRE SPRINKLER ROOM 54 PARKING SPACES 19 76 SF STR. 4 76 SF STR. 5 76 SF STR. 6 GATE SEPARATINGPHASE I ANDPHASE II1 2 3 4 5 6 7 8 9 10 23 22 21 20 19 18 17 16 15 14 13 12 11 29 28 27 26 25 24 30 31 32 33 1 2 13 14 15 21 COMPACT PHASE I 49 SPACES PHASE II 5 SPACES VAN 9 10 11 12 18 FS-CONC-3 3 4 5 6 20 16 17 7 8 16 17 18 19 20 21 22 23 24 PARKING SPACES 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 76 SF STR. 1 COMMON STORAGE EHU FOR SALE LOCK OFF 76 SF STR. 2 130 SF STR. 3 F.A.C.P. 1 INCULDING 1 OUT SPACE TRASH/ RECYCLING PARKING SPACE LEGEND 1 PHASE I PARKING SPACE PHASE II PARKING SPACE1 PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.06 GRFA PLANS - Garage 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/16" = 1'-0"1 Garage Level 1 1/16" = 1'-0"2 Garage Level 2 1/16" = 1'-0"3 Garage Level 3 0' 8' 32'16' 0' 8' 32'16' 0' 8' 32' 16' Area Schedule (GRFA) G 1 TYPE UNIT Area Garage Level 1 COMMON STORAGE STR. 7 77 SF COMMON STORAGE STR. 8 77 SF COMMON STORAGE STR. 9 77 SF COMMON STORAGE STR. 10 369 SF COMMON STORAGE: 4 600 SF 600 SF Area Schedule (GRFA) G 2 TYPE UNIT Area Garage Level 2 COMMON STORAGE STR. 4 76 SF COMMON STORAGE STR. 5 76 SF COMMON STORAGE STR. 6 76 SF COMMON STORAGE: 3 229 SF Area Schedule (GRFA) G 3 TYPE UNIT Area Garage Level 3 COMMON STORAGE STR. 1 76 SF COMMON STORAGE STR. 2 76 SF COMMON STORAGE STR. 3 130 SF COMMON STORAGE: 3 283 SF No. Description Date 12/19/2017 12:00:00 AM DN UP DN UP DN DNDN DN 1185 SF EHU-A 826 SF EHU-C 1167 SF EHU-D 1197 SF EHU-E 825 SF EHU-F 1089 SF EHU-G 1107 SF EHU-H 818 SF EHU-J 455 SF EHU-B COMMON COMMON STORAGE EHU FOR SALE LOCK OFF 2923 SF COMMON 237 SF COMMON Juliet Balcony Juliet Balcony Juliet Balcony Juliet Balcony 835 SF EHU-O 1205 SF UNIT 204 1201 SF UNIT 205 410 SF UNIT 205 - LO 1300 SF UNIT 206 430 SF EHU-L 420 SF UNIT 204 - LO 415 SF UNIT 205 - LO - 2 430 SF UNIT 206 - LO 1191 SF EHU-K 1016 SF EHU-N 1192 SF EHU-P 733 SF EHU-M 536 SF COMMON1536 SF COMMON Juliet Balcony Juliet Balcony Juliet Balcony 1864 SF UNIT 301 461 SF UNIT 302 - LO 1262 SF UNIT 302 1504 SF UNIT 303 1200 SF UNIT 304 1538 SF UNIT 305 368 SF UNIT 305 - LO 377 SF UNIT 301 - LO 275 SF UNIT 302 - LO 2 Redundant Area UNIT 303 - LO 309 SF UNIT 304 - LO 1332 SF UNIT 306 377 SF UNIT 306 - LO 503 SF COMMON 398 SF COMMON 516 SF COMMON PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.07 GRFA PLANS- Building 17021VAIL MOUNTAIN VIEWPHASE II11/22/2017 VAIL MOUNTAIN VIEW DD UPDATE 1/16" = 1'-0"1 Level 1 1/16" = 1'-0"2 Level 2 1/16" = 1'-0"3 Level 3 Area Schedule (GRFA) Level 1 TYPE UNIT Area Comments Level 1 EHU EHU-A 1185 SF 2 BEDROOM EHU EHU-B 455 SF STUDIO EHU EHU-C 826 SF 1 BEDROOM EHU EHU-D 1167 SF 2 BEDROOM EHU EHU-E 1197 SF 2 BEDROOM EHU EHU-F 825 SF 1 BEDROOM EHU EHU-G 1089 SF 2 BEDROOM EHU EHU-H 1107 SF 2 BEDROOM EHU EHU-J 818 SF 1 BEDROOM EHU: 9 8669 SF Area Schedule (GRFA) Level 2 TYPE UNIT Area Comments Level 2 EHU EHU-K 1191 SF 2 BEDROOM EHU EHU-L 430 SF STUDIO EHU EHU-M 733 SF 1 BEDROOM EHU EHU-N 1016 SF 2 BEDROOM EHU EHU-O 835 SF 1 BEDROOM EHU EHU-P 1192 SF 2 BEDROOM EHU: 6 5398 SF FOR SALE UNIT 204 1205 SF FOR SALE UNIT 205 1201 SF FOR SALE UNIT 206 1300 SF FOR SALE: 3 3705 SF LOCK OFF UNIT 204 - LO 420 SF LOCK OFF UNIT 205 - LO 410 SF LOCK OFF UNIT 205 - LO - 2 415 SF LOCK OFF UNIT 206 - LO 430 SF LOCK OFF: 4 1675 SF Area Schedule (GRFA) Level 3 TYPE UNIT Area Level 3 FOR SALE UNIT 301 1864 SF FOR SALE UNIT 302 1262 SF FOR SALE UNIT 303 1504 SF FOR SALE UNIT 304 1200 SF FOR SALE UNIT 305 1538 SF FOR SALE UNIT 306 1332 SF FOR SALE: 6 8701 SF LOCK OFF UNIT 301 - LO 377 SF LOCK OFF UNIT 302 - LO 461 SF LOCK OFF UNIT 302 - LO 2 275 SF LOCK OFF UNIT 303 - LO Redundant Area LOCK OFF UNIT 304 - LO 309 SF LOCK OFF UNIT 305 - LO 368 SF LOCK OFF UNIT 306 - LO 377 SF LOCK OFF: 7 2167 SF Grand total: 13 10869 SF 0' 8' 32'16' 0' 8' 32'16' 0' 8' 32' 16' No. Description Date (GRFA) Unit 204 TYPE UNIT Area FOR SALE UNIT 204 1205 SF LOCK OFF UNIT 204 - LO 420 SF 1625 SF (GRFA) Unit 205 TYPE UNIT Area FOR SALE UNIT 205 1201 SF LOCK OFF UNIT 205 - LO 410 SF LOCK OFF UNIT 205 - LO - 2 415 SF 2026 SF (GRFA) Unit 206 TYPE UNIT Area FOR SALE UNIT 206 1300 SF LOCK OFF UNIT 206 - LO 430 SF 1729 SF (GRFA) Unit 301 TYPE UNIT Area FOR SALE UNIT 301 1864 SF LOCK OFF UNIT 301 - LO 377 SF 2241 SF (GRFA) Unit 302 TYPE UNIT Area FOR SALE UNIT 302 1262 SF LOCK OFF UNIT 302 - LO 461 SF LOCK OFF UNIT 302 - LO 2 275 SF 1999 SF (GRFA) Unit 303 TYPE UNIT Area FOR SALE UNIT 303 1504 SF LOCK OFF UNIT 303 - LO 0 SF 1504 SF (GRFA) Unit 304 TYPE UNIT Area FOR SALE UNIT 304 1200 SF LOCK OFF UNIT 304 - LO 309 SF 1509 SF (GRFA) Unit 305 TYPE UNIT Area FOR SALE UNIT 305 1538 SF LOCK OFF UNIT 305 - LO 368 SF 1906 SF (GRFA) Unit 306 TYPE UNIT Area FOR SALE UNIT 306 1332 SF LOCK OFF UNIT 306 - LO 377 SF 1709 SF 12/19/2017 12:00:00 AM UP UP DN DN 1875 SF UNIT 401 455 SF UNIT 402 - LO 1354 SF UNIT 402 1228 SF UNIT 403 1257 SF UNIT 404 1265 SF UNIT 405 363 SF UNIT 406 - LO-2 1336 SF UNIT 406 367 SF UNIT 401 - LO COMMON STORAGE EHU FOR SALE LOCK OFF 423 SF UNIT 406 - LO 194 SF UNIT 402 - LO 2 253 SF UNIT 404 - LO 264 SF UNIT 405 - LO272 SF UNIT 403 - LO 747 SF UNIT 401 - DORMER 968 SF UNIT 405 - DORMER 817 SF UNIT 406 - DORMER 1048 SF UNIT 402 - DORMER 887 SF UNIT 404 - DORMER 1043 SF UNIT 403 - DORMER COMMON STORAGE EHU FOR SALE LOCK OFF DECK DECK DECK DECK DECKDECK DECK DECK PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.08 GRFA PLANS - Building 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/16" = 1'-0"1 Level 4 1/16" = 1'-0"2 Dormer Level Area Schedule (GRFA) Level 4 TYPE UNIT Area Level 4 FOR SALE UNIT 401 1875 SF FOR SALE UNIT 402 1354 SF FOR SALE UNIT 403 1228 SF FOR SALE UNIT 404 1257 SF FOR SALE UNIT 405 1265 SF FOR SALE UNIT 406 1336 SF FOR SALE: 6 8315 SF LOCK OFF UNIT 401 - LO 367 SF LOCK OFF UNIT 402 - LO 455 SF LOCK OFF UNIT 402 - LO 2 194 SF LOCK OFF UNIT 403 - LO 272 SF LOCK OFF UNIT 404 - LO 253 SF LOCK OFF UNIT 405 - LO 264 SF LOCK OFF UNIT 406 - LO 423 SF LOCK OFF UNIT 406 - LO-2 363 SF LOCK OFF: 8 2591 SF Grand total: 14 10905 SF Area Schedule (GRFA) Dormer Level TYPE UNIT Area Dormer Level FOR SALE UNIT 401 - DORMER 747 SF FOR SALE UNIT 402 - DORMER 1048 SF FOR SALE UNIT 403 - DORMER 1043 SF FOR SALE UNIT 404 - DORMER 887 SF FOR SALE UNIT 405 - DORMER 968 SF FOR SALE UNIT 406 - DORMER 817 SF FOR SALE: 6 5509 SF 0' 8' 32'16' 0' 8' 32'16' No. Description Date (GRFA) Unit 401 TYPE UNIT Area FOR SALE UNIT 401 1875 SF LOCK OFF UNIT 401 - LO 367 SF FOR SALE UNIT 401 - DORMER 747 SF 2989 SF (GRFA) Unit 402 TYPE UNIT Area FOR SALE UNIT 402 1354 SF LOCK OFF UNIT 402 - LO 455 SF LOCK OFF UNIT 402 - LO 2 194 SF FOR SALE UNIT 402 - DORMER 1048 SF 3050 SF (GRFA) Unit 403 TYPE UNIT Area FOR SALE UNIT 403 1228 SF LOCK OFF UNIT 403 - LO 272 SF FOR SALE UNIT 403 - DORMER 1043 SF 2542 SF (GRFA) Unit 404 TYPE UNIT Area FOR SALE UNIT 404 1257 SF LOCK OFF UNIT 404 - LO 253 SF FOR SALE UNIT 404 - DORMER 887 SF 2397 SF (GRFA) Unit 405 TYPE UNIT Area FOR SALE UNIT 405 1265 SF LOCK OFF UNIT 405 - LO 264 SF FOR SALE UNIT 405 - DORMER 968 SF 2497 SF (GRFA) Unit 406 TYPE UNIT Area FOR SALE UNIT 406 1336 SF LOCK OFF UNIT 406 - LO 423 SF LOCK OFF UNIT 406 - LO-2 363 SF FOR SALE UNIT 406 - DORMER 817 SF 2939 SF TOTAL FOR SALE 32,687 15 UNITS WITH 20 LOCK OFFS EHU 13,992 15 UNITS 12/19/2017 12:00:00 AM FSOUTH FRONT A G E RD E 12,599 SQFT ABOVE GRADE EXISTING 12,599 SQFT 22.34% COVERAGE 12,599 SQFT 14,753 SQFT ABOVE GRADE PROPOSED - 27,352 SQFT 48.50% COVERAGE PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.10 SITE COVERAGE 17021VAIL MOUNTAIN VIEWPHASE II08/15/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1" = 20'-0"2 SITE COVERAGE - E 1" = 20'-0"3 SITE COVERAGE - P 0' 10' 40' 20' 0' 10' 40'20' No. Description Date VMVR Development Plan Set 08/15/2017 PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM SOUTH FRONT A G E RD E 39,424 SQFT BELOW GRADE EXISTING 39,424 SQFT 69.91% COVERAGE SOUTH FRONT A G E RD E BELOW GRADE PROPOSED 39,880 SQFT 70.07% COVERAGE 39,880 SQFT PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.10B SITE COVERAGE 17021VAIL MOUNTAIN VIEWPHASE II08/15/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1" = 20'-0"2 SITE COVERAGE SUBGRADE - E 1" = 20'-0"1 SITE COVERAGE SUBGRADE - P 0' 10' 40' 20' 0' 10' 40'20' No. Description Date VMVR Development Plan Set 08/15/2017 PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM 4'DRAIN FDERGROUND EASEMENT 200634246 DN SOUTH FRONT A G E RD E EXISTING 35881 SQFT 63.62% COVERAGE PHASE II Total Area: 25,975 SQFT Landscape Coverage: 20,774 SQFT (79.85%) PROPOSED - 23,094 SQFT 41% COVERAGE PHASE II Total Area: 25,981 SQFT Landscape Coverage: 8,280 SQFT (31.86%) PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.11 LANDSCAPE COVERAGE 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1" = 20'-0" 1 LANDSCAPE COVERAGE - E 1" = 20'-0"2 LANDSCAPE COVERAGE - P 0' 10' 40' 20' 0' 10' 40' 20' No. Description Date 12/19/2017 12:00:00 AM 1 2 3 4 5 6 7 8 10 A B D E 90 7" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12"7" / 12" 12" / 12" 4 3/8" / 12"8214 8212 8210 8208 8216 8218 8220 8214 8212 8216 8218 8220 A +/- 35'-8" JJ +/- 61'-7" KK +/- 69'-2" W +/- 67'-5" V +/- 67'-9" MM +/- 67'-7" X +/- 67'-0" Y +/- 68'-6" LL +/- 68'-2" HH +/- 68'-3" GG +/- 68'-0" FF +/- 67'-3" DD +/- 67' ROOF DECK ROOF DECK ROOF DECK ROOF DECK ROOF DECK ROOF DECK NN +/- 68'-11" EE+/- 67'-8" CC +/- 65'-11" BB+/- 61'-10" Z +/- 63'-4"L +/- 68'-6" QQ+/- 57'-0" M +/- 68'-0" P +/- 69'-2" Q +/- 68'-8"S +/- 69'-6" ROOF DECK AA +/- 69'-0" J +/- 56'-11" B +/- 55'-4" D +/- 52'-4" E +/- 51'-4" U +/- 57'-3" R +/- 59'-7" SS +/- 58'-10"N +/- 57'-9" C +/- 64'-10" PP +/- 55'-3" F +/- 62'-8" T +/- 60'-3" RR +/- 61'-9" G +/- 60'-5" RIDGE: EAVE: EAVE: EAVE: EAVE: RIDGE: EAVE:EAVE:EAVE:EAVE: EAVE: RIDGE:RIDGE: EAVE: RIDGE: RIDGE: RIDGE: RIDGE: RIDGE: RIDGE: RIDGE: RIDGE: RIDGE: RIDGE: H +/- 52'-0" EAVE: 8.5 8 2 2 0 8 218 8 216 8 2 1 4 8 2 1 2 8 2 0 8 8210 8212 8 2 1 4 8216 8 2 1 8 8220 RIDGE: K +/- 69'-10" RIDGE: 23 : HVAC EQUIPMENT RE. MECHANICAL 23 : HVAC EQUIPMENT RE. MECHANICAL PARAPET TO SCREEN MECHANICAL EQUIPMENT 15' - 8" 15' - 8" C 1" / 12"8250.5 8276.6 8247.5 8280.6 8268.3 8272.1 8268.3 8280.3 8276.6 8276.6 8269.1 8283.88283.8 8280.6 8269.18269.1 8273.58276.5 8278.7 8268.3 8279.3 8268.3 8277.7 8268.3 8277.7 8268.3 8268.3 8279.8 8281.5 8281.1 8280.9 8282.6 8281.9 8281.9 8281.8 8280.3 8281.98279.9 8279.4 8281.9 8281.9 PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.12 ROOF HEIGHT 17021VAIL MOUNTAIN VIEWPHASE II08/15/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 ROOF HEIGHT PLAN 0' 4' 16'8' No. Description Date VMVR Development Plan Set 08/15/2017 PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM 22 8222 8214 8212 8210 8208 8216 8218 8220 8214 8212 8210 8216 8218 8220 8206 8206 8208 8204 8202 8180 8204 8202 8200 8190 MOUNTAIN VIEW PHASE I TYROLEAN 8220 8 2 1 8 8216 8 2 1 4 8 2 1 2 8210 8 2 0 8 8206 8204 8202 8200 8 2 0 2 8190 8 1 8 0 8 2 0 4 8206 8208 8210 8212 8214 8216 8218 8220 8222 RIDGE: PARAPET TO SCREEN MECHANICAL EQUIPMENT 23 : HVAC EQUIPMENT RE. MECHANICAL 23 : HVAC EQUIPMENT RE. MECHANICAL PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A2.13 HISTORIC GRADE MAP 17021VAIL MOUNTAIN VIEWPHASE II08/15/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1" = 10'-0"1 HISTORIC GRADE MAP 0' 5' 20'10' No. Description Date VMVR Development Plan Set 08/15/2017 PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM Note: The colors and textures depicted here are to convey transitions and architectural articulation. Physical material samples will be presented during the design review process. PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A4.00 3D MASSING 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET Looking North Looking South Looking South 04 2200 ; ANCHORED STONE MASONRY VENEER 07 4600 : COMPOSITE SIDING 07 4213 : METAL WALL PANEL 2 06 1323 : TIMBER TRELLIS 07 4113 : METAL ROOF PANEL 1 07 4213 : EIFS STUCCO No. Description Date 12/19/2017 12:00:00 AM Note: The colors and textures depicted here are to convey transitions and architectural articulation. Physical material samples will be presented during the design review process. PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A4.00 3D MASSING 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET Looking North Looking South Looking South 04 2200 ; ANCHORED STONE MASONRY VENEER 07 4600 : COMPOSITE SIDING 07 4213 : METAL WALL PANEL 2 06 1323 : TIMBER TRELLIS 07 4113 : METAL ROOF PANEL 1 07 4213 : EIFS STUCCO No. Description Date Looking North 12/19/2017 12:00:00 AM Level 1 8226' - 0" Level 2 8236' - 6" Level 3 8247' - 0" Level 4 8258' - 0" Dormer Level 8269' - 0" Garage Level 3 8214' - 6" AB D E 84' - 0" 23' - 0" 43' - 6" 17' - 6" C Note: The colors and textures depicted here are to convey transitions and architectural articulation. Physical material samples will be presented during the design review process. PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A4.02 OVERALL BUILDING ELEVATIONS 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 East Elevation MATERIAL LEGEND Key Value Keynote Text 07 4213 : EIFS STUCCO 04 2200 ; ANCHORED STONE MASONRY VENEER 07 4600 : COMPOSITE SIDING 07 4213 : METAL WALL PANEL 2 06 1323 : TIMBER TRELLIS 07 4113 : METAL ROOF PANEL 1 No. Description Date 12/19/2017 12:00:00 AM Level 1 8226' - 0" Level 2 8236' - 6" Level 3 8247' - 0" Level 4 8258' - 0" Dormer Level 8269' - 0" Garage Level 3 8214' - 6" A B D E 84' - 0" 17' - 6" 43' - 6" 23' - 0" C Note: The colors and textures depicted here are to convey transitions and architectural articulation. Physical material samples will be presented during the design review process. PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A4.03 OVERALL BUILDING ELEVATIONS 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 West Elevation MATERIAL LEGEND Key Value Keynote Text 07 4213 : EIFS STUCCO ANCHORED STONE MASONRY VENEER 07 4600 : COMPOSITE SIDING 07 4213 : METAL WALL PANEL 2 06 1323 : TIMBER TRELLIS 07 4213 : METAL ROOF PANEL 1 No. Description Date 12/19/2017 12:00:00 AM Level 1 8226' - 0" Level 2 8236' - 6" Level 3 8247' - 0" Level 4 8258' - 0" Dormer Level 8269' - 0" 1 2 3 4 5 6 7 8 10 29' - 6"26' - 2" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 28' - 2"16' - 8" 06 1323 : TIMBER TRELLIS 213' - 2" 8.5 Note: The colors and textures depicted here are to convey transitions and architectural articulation. Physical material samples will be presented during the design review process. PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A4.04 OVERALL BUILDING ELEVATIONS 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"2 South Elevation MATERIAL LEGEND Key Value Keynote Text 06 1063 A1 06 1323 : TIMBER TRELLIS 07 4213 : EIFS STUCCO ANCHORED STONE MASONRY VENEER 07 4600 : COMPOSITE SIDING 07 4213 : METAL WALL PANEL 2 06 1323 : TIMBER TRELLIS 07 4213 : METAL ROOF PANEL 1 No. Description Date 12/19/2017 12:00:00 AM Level 1 8226' - 0" Level 2 8236' - 6" Level 3 8247' - 0" Level 4 8258' - 0" Dormer Level 8269' - 0" 12 3 4 5 6 7 8 10 213' - 2" 29' - 6" 26' - 2" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 28' - 2" 16' - 8" 8.5 Note: The colors and textures depicted here are to convey transitions and architectural articulation. Physical material samples will be presented during the design review process. PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A4.05 OVERALL BUILDING ELEVATIONS 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 North Elevation MATERIAL LEGEND Key Value Keynote Text 07 4213 : EIFS STUCCO ANCHORED STONE MASONRY VENEER 07 4600 : COMPOSITE SIDING 07 4213 : METAL WALL PANEL 2 06 1323 : TIMBER TRELLIS 07 4213 : METAL ROOF PANEL 1 No. Description Date 12/19/2017 12:00:00 AM                                               ߰!"#$!% $   ߰!"#$!% $ & '(&            '$!%) *   )߰+ , ߰# ߰+ , ߰# %, %, %, $ $ $ %, %, %, %, %, $-'  $ 1 2                      ߰    !          "##           12/19/2017 12:00:00 AM DN FIXTURES Bollard Wall Accent PROJECT NUMBER ISSUE DATE 3630 OSAGE STREET DENVER, CO 80211 720.512.3437 REVISION SHEET TITLE ISSUE SHEET NO.434 SOUTH FRONTAGE ROAD EAST,VAIL, CO 81657TOWN STAMP DISCIPLINE STAMP A9.11 LIGHTING PLAN 17021VAIL MOUNTAIN VIEWPHASE II09/14/2017 VAIL MOUNTAIN VIEW RESIDENCE DEVELOPMENT PLAN SET 1/8" = 1'-0"1 LIGHTING PLAN 0' 4' 16'8' No. Description Date 12/19/2017 12:00:00 AM                                              ߰!"#$!% $   ߰!"#$!% $ & '(&            '$!%) *   )߰+ ߰+ , %, %, %, %, $ $ $ %, %, %, %, %, $-'  $  1 2                      ߰    !          "##           12/19/2017 12:00:00 AM Design Prior to 12-5-17 Town Council Meeting Revised Design south elevation comparison MOUNTAIN VIEW_ VAIL, CO Design Development \\ December 2017 Solar 12/19/2017 12:00:00 AM south elevation MOUNTAIN VIEW_ VAIL, CO Design Development \\ December 2017 12/19/2017 12:00:00 AM 12/19/2017 12:00:00 AM 12/19/2017 12:00:00 AM PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM 12/19/2017 12:00:00 AM PROJECT NUMBER ISSUE DATE REVISION ISSUE 17021 09/14/2017 No. Description Date 12/19/2017 12:00:00 AM