E17-0141 plans approved.pdf
• - - Y Town of Vail TOV STAMP OFFICE SYMBOLS POWER SYMBOLS NOTES GENERAL NOTES 1.ALL WORK SHOWN IS NEW,UNLESS NOTED OTHERWISE. (E)MAIN DISTRIBUTION PANEL MDP-SECTION 2 MOTOR OUTLET 2.ALL WORK TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE,2014 EDISON. 480/27N,800-AMP, 3PH, 4W FUSED DISCONNECT SWITCH 3.SEAL ALL CONDUIT PENETRATIONS OF FLOORS AND FIRE RATED ASSEMBLIES TO r 1 SWITCH%%/X%/XX=AMP SCONNEPOLESITCH FUSE HEW OLDY NON-FUSED DISCONNECT SWITCH MAINTAIN FIRE RATING. �ap SWITCH XX/ti-AMP SWITCH/POLES 4,PROVIDE NEW TYPEWRITTEN DIRECTORIES REFLECTING WORK PERFORMED FOR ALL (E)400A FEEDER 181 COMBINATION MOTOR STARTER NEW PANEI.BOARDS IN THIS PROJECT.PLANSAR (E)4003/400AS VAIL BUS BARN • ST •MANUAL MOTOR STARTER WITH THERMAL OVERLORD NUMBERS. PROVIDE AND INSTALL ALL CONDUITS,CONDUCTORS,RO%ES, ' STATIONARY-CIRCUIT BREAXER;RATING AS MISCELLANEOUS FITTINGS.ETC.FORA COMPLETE AND OPERABLE STSIEM 2"C-3#2/0 AWG CND PAINT BOOTH ...-1 SHOWN ON PIANS SPECIFRICATIONS AND N ERCNCH CIRCUIT INSTALLATION SHALL COMPLY WITH ' %FMR (E)100A FEEDER Vail,CO ® SWITCH AND FUSE:RATING AS SHOWN ON PLANS 6.ALL NEUTRAL CONDUCTORS ON POWER BRANCH CIRCUITING ROUNDHOUSES TO (E)400AF/400AS 112.5 KVA BE#10 AWG UNLESS NOTED OTHERWISE. 3P TO EXISTING480/208-I20V 10-./,- STITCH AND NSE:RATING AS SHOWN ON PLANS ° D PANELS (E)PNLP-2PNL (E)PNLOP-i (E)PNL O, m JUNCSON BOA PP-2 RP-5 SODA SBP-i 400A -400A t00A 100A SHEET LIST MLO MCB MLO MLO SURFACE MOUNTED PANELBOARD OR TERMINAL CABINET =O7 � E1.0 SYMBOLS,ONE LINE DIAGRAM AND PLAN (E)200AF/200A5 <C> 3P TO EXISTING E1.1 SCHEDULES 0 PANELS 2x(2-1/2"C-4#3/0 AWG & #2 GAD) E2.0 SPECIFICATIONS L DIAGRAM NOTE$ RISER NOTF4 1. ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED. <> PROVIDE(1)#3/0 ANG GROUND WIRE TO NEAREST PUN NOTES GENERAL NOTES 2. BRING ANY DISCOVERED CODE VIOLATIONS TO THE OWNER'S ATTENTION. BUILDING STEEL 0 PROVIDE MECHANICAL UNIT WITH 1-1/2"C - 3#2 AWG GND. 1. ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED. 3. ALL WIRING SHOWN IS SIZED FOR COPPER CONDUCTORS,UGH. O PROVTOE NEW PANEL SHOWN WITH INCREASED BUS SIZE PER THE PANEL SCHEDULE. RECONNECT ALL IJOSTING LOADS OPROVIDE CONNECTION FROM EXISTING CIRCUITING TO NEW UNIT 2. PROVIDE TYPEWRITTEN DIRECTORIES REFLECTING ALL AS SHOWN IN PANEL SCHEDULE. WITH NEW VFD. NEW WORK PERFORMED IN THIS PROJECT. 03 VFD SHALL BE FACTORY INSTALLED AND WIRED INSIDE THE UNIT. 3. VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT WITH EXISTING CONDITIONS IN THE FIELD. '11111 'y O VFD SHALL BE FURNISHED BY MECHANICAL CONTRACTOR AND O SINGLE LINE DIAGRAM INSTALLED BY ELECTRICAL CONTRACTOR. 4. ALL EQUIPMENT SHOWN IS CONNECTED TO PANEL'RP-5',UON. NTS 0 PROVIDE NEW MOTOR WITH 3/4"C- 48 ARC
 GND. 5. REMOVE ALL CONDUCTORS,DEVICES AND CONDUIT RENDERED CIRCUIT BREAKER IN PANEL SHALL REMAIN. UNUSED BY THIS PROJECT. WILDER ENGINEERING LLC Andrew Wilder PE Town of Vail Blue Sage Drive mboat Springs,CO 80487 Mk j(E)� Stea REVIEWED FOR CODE P:97 V E:andy@wilder-eng.com r 12 3P PP-2< , Date: Z.�—,( • © 0 R ..- rJ -LJ a0DY SHOP 0A5 fj 3P / 30 '� By• >OS;"G�V+IF`as 4V ,_. i. -QPpDU 1/cFhyl 'AINT PREP 3234,360 \ PP.II:T 30GTI-I """"© �-�::% < , �a a4 mo l _i_ -1<C> S Code: G ;, 49009 ° m J_. f , ;•"7,,o; (E)SBP-1 IIIh ✓TYRE ENG - Issue By Date&Issue Description By - PERMIT SET 3.17.17 AW my—RP-5 75 NVA TRANSFORMER lie' II. IE ll (E)PP2 OillialIND H g ELECTRICAL PLAN qC!/..d. scale: 24436 NTS LOAD CALCULATION& 'N(_)I'I(: �E Description:ONE LINE DIAGRAM Project Name:VAR BUS BARN PAINT BTH H 1 (OMAN DISTRIBUTION PANEL H (EAST OF LOCATION SHOWN) 6 Project Number:201705 Sheet No. I E1.0 TOV STAMP I EXISTING I EXISTING MOUNTING SURFACE PANEL GP-1 10,000 ALC.SYM MOUNTING SURFACE PANEL PP2 25.000 ALC.STM 208/120 VOLTS 3 PHASE 4 WIPE MAIL MLO BUS 100A 480/277 KYTS 3 PHASE 4 WIRE MAIN MLO BUS 40DA VOLT AMPS R L O B C C a o L R VOLT AMPS VOLT AMPS R LOB c CDOER VOLT AMPS SEEK I 1 K L T E E T L K I R I KR L T E 0A OB 07 DESCWP11ON C B E R R R R E D � C D1Pn°N B 0A 0 0C 04 OB OC 7TCM C 0 E R R E O C DESCRWMN 0A CM OC 5670 Pares s8P-1 3 100 1 A 2 20 1 2 R«ep6 _ 380 3601 Welder 3 25 1 A 2 175 3 imperial RP-5 28864 CO i 4420 - - - 3 B 4 20 1 2 Recepb _ 360 3800 - 3 B 4 - - -30224 3800 - - - 5 C 6 20 1 2 Racepb 300 3600 - - - S C 6 - - - 31584 Space 7 .A s ram 20 1 2 Racepa 360 2770 C 3•20 7 A a 20 3 Weider 2770 .. VAIL BUS BARN Space 9 B 10 20 1 Heat 500 2770 - - - 9 B 10 - - - 2770 Space II C 12.20-1 Ray V« 250 2770 - - - II C I2 - - - -2770 PAINT BOOTH 50ece 13 A 14 20_1 2 R«epb 360 2213 Wash lbab 3 15 13 A 14 15 3 Exhaust 2200 Span _15 B 16 20 1 2 Raceple 380 2200 - - 15 B 50 - - - 2200 Vail,CO 100 100001008 I 20 17 C II 20 1 SParo 2200 - - - 17 C M - - - 2200 500 Beat Tape 2 15_IV A20 20 1 Spare 2200 Milmool 3 15 19 A 20 15 3 X0063 2200 500 - - - II B..25 20 1 2 Recepb 360 ,2200 - - - 21 B 22 - - - 2200 250 60161 20 23 C 24 Space 2200 - - A C 28 - - - .2200 Spam 20 n A 26 20 1 2 Ramps 360 2200 Healer 3 15 25 A 26 80 2 Walder 8300 360 R«epl 2 20 27 0 26 20 1 2_ R«epb 380 2200 - - - 27 B 20 - - - 8300 360 R«ep1 2 20 29 C 30 20 1 2 R«epb 360 2200 - - - - 29 C 30 20 1 LD ,2500 380 Receipt 2 20 II A 32 20 1 2_ Recepb 380 2500 16 1 20 31 A 32 20 3 Gamma DMO 2770 380 Recaps 2 20 31 0 14 20 1 2 R«epb 360 2500 16 1 20 33 B 34 - - - 2770 Space 35 C 36 30 2 Welder 1500 2500 16 1 20 35 C 36 - _ - 2770 Specs 37 A 10 - - - 1500 2500 Irl 1 20 37 A 30 20 3 Healy 2770 Spas. 39 B 40 50 2 Welder 3000 2500 16 1 20 39 8 40 - - - 2770 Space 41 C 42 - - - 3000 2500 LIB 1 20 41 C 42 - - - 2770 6530 5860 4310 YAAINE 3300 5300 5470 17070 17970 17970 VAA06 48874 51234 46774 OA- 9830 017- 10840 OC- 9780 0A= 87844 09-692M 0C- 64744 (ANTRNQIS LOADS NON-CONTINUOUS LOADS CONTINUOUS LOADS 30354-COWI1NL50U6 LOADS UP 1010 kVA 7200 x1 00= 7200 11070 IOWA 10000 20187 10000 1800 01.25= 225D RECEPTACLES 01760 21550 x1.00 21550 193300 31.'3= 24125 RECEPTACLES 07168 WPM 0100 60880 REMAINDER 0.50- IUAIAIMER 4281 0.50- 2140 TOTAL DESIGN kVA= 31 TOTAL DESIGN AMPS- 86 TOTAL DESIGN kVA- 204 TOTAL DESIGN AMPS= 248 (1)Poled.nen beaker as shown. I EXITING MOUNTING SURFACE PANEL SBP-1 10.000 A.I.C.SYM MOUNTING SURFACE PANEL RP-5 70.000 A.I.C.SYM 208/120 VOLTS 3 PHASE 4 WORE MAIN MLA BUS 1004 208/120 7OC7s 3 MASE 4 WIRE MAIN 400A BUS 4004 WILDER ENGINEERING LLC — Andrew Wilder PE SOLI AMPS RE O B c C B 0 L R SORT AMPS VOLT AMPS R L O B C c B 0 L R VOLT AMPS 1170 Blue Sage Drive ETL K I 1 K L T E E T L K I n K 1 TE OA 0B 0C DES'imm°H COS R 0 B R E O C DESCRIPTION 0A 013 (1C 0A (311 OC OFS(MP N C 0 E R R R R E 0 C DESCRIPTION DA 0B 0C Steamboat Springs,CO 80487 Span 1 A 2 5pece 500 filiation 1 20 I A 2 20 1 Spare P:970-819-7848 Space 3 B 4 ligan 500 46ea00 1 20 1 B 4 20 1 CO Sy667n 250 E:andy@wilder-eng.com • Space 5 C 6 Span 500 Wean 1 20 5 C 6 20 1 COSIlem 251 600 Paint Mar 2 20 7 A a 30 3 cliMeu ustFan 1500 360 Recept 2 1 20 7 A 5 30 3 Nash Bay ,2407 600 - - - 9 B 10 - - - 1500 960 Recep1 2 1 20 9 B 10 - - - 2407 500 Heal 1 20 II C 12 - - - 1500 380 Romp/ 2 I 20 11 C 12 - - - 2407 500 Heal 1 20 13 A 14 20 I 8150363 750 500 Chop 5320 1 20 II A 14 30 2 Weider 153 500 Heat I 20 15 B 16 20 I 16 800 500 FIRn 2 20 15 B 16 - - - 1500 ..�•..� 33\343 500 Heat I 20 n c to 20 1 LIg 600 500 - - - n C 050 2 Plasma Carter 3000 -5-p5POO L/Cf-I11j1 500 Heal 1 20 I9 A 20 20 1 16 800 9830 Panel 09.1 3 100 Is A 20 - - 3040 p3', •.� s,03 R(F tiU'4 4a7, 500 Ah Pump 2 20 21 B 22 29 1 4 R«ap6 720 70910 - - - 21 B 22 50 2 Renpl 3000 ..7,,:i,,,,...,, v4-22 i 500 - - - 23 C 24 20 1 Span 0780 - - - 23 C 24 - - - 3000 i •0 49009 v; 1 720 Recap6 4 1 20 25 A 26 20 1 AhPump 500 1083 TieCalerael 3 t5 33 A 26 20 3 Punch Rubins 1805 i/37\� / Span 27 0 26 Span 1063 - - - n B 2R - - - 1605 •. ,/,7_, �' .-- Span 29 C 30 Space 10833 - - - 29 C 30 - - - 1805 1431 ,V(-. _ 2320 1800 1500 3•A 118E 3350 2820 2100 500 Qintex 1 20 31_A_12 90 3 IN)MAL I.2 5798 h A n XV•0°,1" 0A= 5670 01F. 4420 0r- 3800 500 Dertvw. 2 20 33 B 34 - - - 5798 CONIINUO/1510AM NON-COSTINLIOUSLOADS 500 _ - 5798 UP 7010 WA 1440 5187 1440 500 00446 2 20 37 A 30 15 3 The C morel 1083 11300 /5.n-- 2250 REST ALEES OTHER 10650 000 10450 500 - - 19 0 40 - - - 1083 REMAIN 030=_ 1500 Tae MaoMm 1 20 41 C 42 - - - 1084 Issue By Date&Issue Description By TOTALDESI@S kVA= 14 TOTAL DESIGN AMPS= 39 19273 14383 14223 VA RINE 15591 15841 17341 - PERMIT SET 3.17.17 AW 04= 20864 01300 30224 0C- 31584 LUST MTIIKANT.WADS N@KYriT61l101US LOADS 18644 0'S- 4161 10170101601 10000 51.87 10000 RDEHLA(IES OTHER 74572 x460 74572 1600 515- 2250 RFM-AIImER 4260 OSB 2140 TOTAL DESIGN kVA= 93 TOTAL DESI6117 AMPS- 258 Town of Vail . REVIEWED FOR CODE - COMPLIANCE Stale: -�� 24,36 NTS Date: - -2.-F---T./'- Description:SCHEDULES By: Pro)ect Name:VAIL BUS BARN PAINT 610 Code. -- -- ......7"--------_________ -- Project Number:203705 OPANEL SCHEDULES NTS Sheet No. E1.1 TOV STAMP SECTION 16010-BASIC ELECTRICAL REQUIREMENTS SECTION 16100-BASIC MATERIALS AND METHODS vii)Overcunen(Protection Devices:Molded case circuit breakers for branch panelboards and 120/208V rated distributIon 1)PART 1 GENERAL 1)PART 1 GENERAL panels,and fusible switch units for 277/48011 rated distribution panels. a)POWER AND CONTROL WIRING a)REFERENCES g)MOTOR STARTERS I)Provide power system conduit and wiring to mechanical equipment.Controls system conduit and wiring for mechanical I)All equipment and installations shall meet or exceed minimum requirements of ADA,ANSI,ASTM,IEEE,IES,NEC,NEMA, D Acceptable Manufacturers:Eaton/Cutler-Hammer,General Electric.Siemens,or Square D/Groupe Schneider. systems is included under Division ES."Power wiring includes line voltage wiring from distribution apparatus to NETA.NFPA.OSHA,SMACNA,UL and the State Fire Marshal.Equipment shall be certified for use in the State of the II)Manual Motor Starters disconnecting means provided or installed under this section,and from such disconnecting means to motors,and to project and shall meet the State energy code.Provide products and materials that are new,clean,free of defects,and iii)Nactionai Horsepower Manual Starter.General-purpose,Class A,manually operated,frit-voltage controller for terminal boxes of'package'equipment."Controls wiring includes wiring,regardless of voltage,which provides free of damage and corrosion. fractional horsepower induction motors,with thermal overload unit,and toggle operator.start-stop control for mechanical equipment and/or which is used to monitor functions of mechanical systems.Where b)PERFORMANCE REQUIREMENTS and Thermal Element:As required by motor controller. line voltage wiring is extended from a local disconnecting means to relays,thermostats,by-pass limenivVolta,starter coils or ) ge,Rating the like,or from mechanical control panels or motor control centers to control device;such extensions are considered i)Provide support system for equipment and conduit,including wiring with a minimum safety factor of 4.For empty vl Enclosure:NEMA ICS 6;Type 1, "control"wiring. conduits,include weight of 0 type XHHW wires of maximum permissible size. h)PULL UNE b)MOUNTING HEIGHTS cl QUALITY ASSURANCE II 1/8 Inch diameter braided yellow polypropylene. 1)Mounting heights and locations:verify the exact locator of equipment with architect prior to Installation.Wall I)All equipment and Installations shall meet orexceed minimum requirements of ADA,ANSI,ASPM,IEEE,IES,NEC,NEM0. mounted devices requiring operational access shall be mounted a minimum of ES inches above finished floor to bottom NETA,NFPA,OSHA,5MACNA,UL and the State Fire Marshal.Equipment shall be certified for use in the State of the of device and a maximum of 48 inches above finished floor to top of device.Visual alarms shall be mounted not less project and shall meet the State energy Code.Provide products and materials that are new,clean,free of defects.and 3)PART 3 EXECUTION than 80 inches la the bottom or 96 inches to the top of the device. free of damage and conoslon. a)INSTALLATION c)REGULATORY REQUIREMENTS I)Conduit VAIL BUS BARN I)Conform to: 2)PARI 2 PROOUCfS (3) Install conduit In accordance with NECA"Standard of Installation". a)CONDUIT 11) NEPA-70-National Electric Code. d General (2) On not combine individual homeruns Into common conduit, PAINT BOOTH Ill Comply with the current applicabk codes,ordinances,and regulations of the authority or authorities having 0) Do not support conduit with wire or perforated pipe straps.Remove wire used for temporary supports jurisdiction,the Owner's insurance underwriter,and applicable base building standards. (1) Exposed Dry and Damp Locations: 14) Arrange conduit to maintain headroom and present teat appearance. Vail,CArrange 1111 When conflict exists between two or more governing codes,comply with the stricter requirement. (a)Use electrical metallic tubing. IS) Use conduit hubs to fasten conduit to cast boxes. kmootain permits,and request inspections horn authority having jurisdiction. (2) Concealed Locations: (61 Provide Insulated equipment ground conductor In flexible conduit dl PROTECT/SITE CONDITIONS (alFurned.Ceiling Spaces and Stud Walls:Use electrical metallic tubing. Ill Install conduit to preserve fire resistance rating of partitions and other elements. Il Install Work in locations shown on Drawings,unless prevented by Project conditions.Coordinate installation of work in (b)Connections to Lighting Fixtures in Accessible Ceilings:Use flexible conduit. 181 Do not attach conduit to ceiling support wires. available space with work furnished under other Divisions. (3) Equipment Connections: ill Building Wire and Cable 2)PRODUCTS (a)Connections to Uquld-Handling Equipment in Dry Locations:Use liquid-tight Ruble conduit. III Use conductor not smaller than IDAWG for power and lighting circuits. a)Where manufacturer's model or series numbers am specified or shown,these Indicate generally acceptable types (4) Equipment for Dry Systems in Dry Locations:Use flexible conduit, required.Furnish products which comply with all requirements,as specified or shown. ill Electrical Metallic Tubing: (2) Neatly train and lace wiring inside boxes,equipment,and panelboards. b)When more than one urn of the same slabs of equipment is required,provide unite produced by a single manufacturer. (3) Make splices,taps,and terminations to carry full empathy of conductors with no perceptible temperature rise. (1) Continuous,seamless steel tubing galvan 1,t or therardized on exterior,coated on Interior with smooth hard 6 Use hardened and tempered TESTS finish of lacquer,varnish or enamel,with steel,set screw or compression type fittings.Provide concrete type I 1 steel,tin-plated or stainless steel Belleville washer with slightly larger tin-plated a)Furnish test equipment,facilities,and technical fittings where required mild steel flat washer for aluminum lugs. pore personnel required to perform Ned tests. 5 Use insulated sconnectors with plastic b)At comletionofob,check voltage at severalpoints of utilization on thesstem.Energize all loads Installed. 121 Usefor general purpose feeders and branch circuits. ()smaller. spring AWG and 4)CLEANING iii)Flexlble Steel Conduit: IIUBoxes a)Clean all fixtures and equipment at the completion of the project.Wipe clean exposed lighting fixture reflectors and (I) Single strip,continuous.flexible interlocked double.wrapped steel,hot dip galvanized Inside and out forming Doth internal wiring channel,with steel,compression type fittings. Ill Install electrical boxes as shown on Drawings,and as required for splices,taps,wire pulling,equipment trim pieces with anon-abrasive cloth just prim to occupancy. connections and compliance with regulatory requirements. ' 5)RECORD DRAWINGS (2) Use in dry locations only,connections to lighting fixtures In suspended ceilings,connections to equipment installed above suspended ceilings,transformer connections,busway plug In units,and connections to equipment (2) Install electrical boxes to maintain headroom and to present neat mechanical appearance. a)Upon completion of the Work,deliver to Architect and up-to-date set of as-bulli"record drawings on a reproducible where vibration isolation is required,maximum length of 6 feet. (3) Install bones to preserve fire resistance rating of partitions and other elements;arrange boxes to meet medium Including AutoCAD. iMliquid Tight Flexible Steel Conduit: regulatory requirements. 6)DEMDDTIDN (1) Same as flexible steel conduit except with tough.inert,watertight plastic outer jacket.Fittings shall be cast 14) Align adjacent wall-m°unted outlet boxes for switches,thermostats,and similar devices to each other. a)Remove,reioote,and rerouteexisting electrical equipment to facilitate new construction or remodeling work, malleable iron body and gland nut,cadmium plated with one-piece brass grounding bushings threaded to interior (5) Do not use through-walls boxes or install Rush mounting boxes back-to-back in walls;provide minimum 6 inch b)Examine the site to observe and note existing conditions prior to submitting a bid. of conduit Spiral molded vinyl sealing ring between gland nut and bushing and nylon Insulated throat separation.Provide minimum24 Inches separation in acoustic rated walls. cl Schedule demolition in advance.Schedule work to avoid disnsption of normal operations. (2) Use same as flexible steel conduit in damp or wet locations and at motor connections. (6) Usestamped steel bridges in bar hanger assembles to fasten flush mounting outlet box between studs. dl Reconnect circuits serving equipment required to remain In serolce to other pandboards,motor control centers,or b)BUILDING WIRE AND CABLE (7) Use adjustable steel channel fasteners for hung ceiling outlet boa. other appropriate distrlb.on equipment Provide additional panelboards.motor control centers,or other appropriate i)Provide wire with a minimum Insulating rating of 600 volts,except for wire used in low voltage(below SO volts)control (8) Do not fasten boxes to ceiling support wires. distribution equipment where there is insufficient available capacity In remaining existing equipment tor reconnection. or signal systems.The use of teflon(multi-conductor)for low tension systems may be permitted for fist alarm,signal IBI Support steel metal boxes independently of conduit. e)Remove existing conduit and wire back to panelboard,motor control center,or other distribution source. and communication systems(voice and data)as approved on shop drawings by engineers and where permitted by local I)Where a circuit is interrupted by removal m a device or fixture from that Cif OM.prsolde additional conduit and wire to codes and union practice. (10) Use gang box where more than one device amounted together,including floor boxes.Do not use sectional restore service to the remaining devices and fixtures on that circuit II)Conductors (13) Plaster Rings:Use for all concealed work;depth of rings as required to reach finished surfaces. g)Electrical equipment to be removed that is in good working order shall be carefully removed and offered to the Owner. (1) Electrical grade.annealed copper,and fabricated in accordance with ASTM standards.Minimum size number Items rejected by the Owner shall be removed from the project site and properly disposed of. 12 AWG for branch circuits;number 14 AWG for control wiring, (12) Coordinate trimming of openings for outlet boxes in partitions to achieve neat,closely-fdtng openings. (2) Unless otherwise specintd,ail wires numbers 10 and smaller shall be solid- 113) Install knockout closure in unused box opening. WILDER ENGINEERING LLC (31 All wires numbers and larger shall be stranded In accordance with ASTM Class 8 stranding designations. Iv)WlnngDevices Andrew Wilder PE (4) Control wires shall be stranded in accordance with OSTM Class B stranding designations. 5) Install devices plumb,level,and rigidly in place. 1170 Blue Sage Drive (5) Cables for low tension systems shall be multi-conductor,16 gauge,color coded and insulated in armored cable (2) Install switches 2 inches to 8 inches from trim on the strike side. Steamboat Springs,C08O4B7 assembly,with number of conductors as required. (31 Install decorative plates on switch,receptacle,and blank outlets in finished areas.Use multi-gang plates for (6) All 600 volt wire and cables unless otherwise specified shall be single condurtor suitable for use in wet and dry multiple devices. P:970-819-7848 and locations. (4) Connect wiring devices bysweeping conductor around screw terminal. E:andy@wilder-eng.com hi)Connectors v)Supporting Devices (1) Make connections.splices,taps and joints with solderless devices,mechanically and electrically secure.Protect (1) Fasten hanger rods,conduit clamps.and outlet and junction boxes to buildingstructure using sed wires and connecting devices with electrical to Insulation to provide insulation values not less than 1 [expansion expo g pe or prov anchors,beam clamps,steel ramset fasteners. on conL (1) Use toggle bolts or hollow wall fasteners in plaster or gypsum board partitions and waits;sheet metal screws or N)Cables(No.t 8 and and Larger): spring steel bar retainer clips in sheet metal studs. III Use set screw or compression type connectors,taps and splites specifically designed for the particular (3) Do not fasten supports to piping ductwork,mechanical equipment.or conduit. .sxstksi connection.Insulate splice either by taping or by use of"Bakelite"covers designed to fit around splice. = p00.L (41 Do not use powder-actuated anchors without specific permission. pP,... CE Ill v)Branch Circuit Wires(Number 10 and Smaller):Use any of the following types of terminals and connecting devices: p';••GHARLE".7ssP slit (1) Hand Applied:Coiled,tapered,spring wound devices with a conducting conoslon.resistant coatingthe IS) Do not drill structural steel members without specific permission. V• .4 1A'0 sort steel and a plastic cover and skirt g splice over y (6) Fabricate supports from structural steel or steel channel,rigidly welded or bolted topresent a neat a ng providing full insulation tarand wired ends.Screw connector on by r ly appearance. ,',5,i' G hand Use hexagon heat)bolts with spring lock washers under nuts. x :a 49009 bon vi)Electncal Identification 'ii,,.y / L• (2) Tool Applied:Steel cap,with conduction and corrosion resistant metallic plating open at both ends,fitted , O�/' �% around the twisted ends of the wire and compressed or crimped by means of a special die designed for the cal Provide wire markers on each conductor In panelboard gutters,pull boxes,and at load connection.Identify ..11;.11 �'��/1{} ''G."- c) d'� ppose.Specifically fitted plastic or rubber insulating cover wrap over each connector. with branch circuit for power and lighting circuits,and with control wire number as indicated on equipment 1j111`;i 'E . c)BOXES manufacturer's shop drawings for control wiring.If more than one neutral conductor is present,mark each with related dreult numbers. I)Pressed steel,galvanized or cadmium-plates),4 Inches minimum octagonal or square with galvanized cover or extension 121 Color code all secondary branch circuit and feeder conductors as follows: ring as required. II)Back-to-back outlets In the same wall.or"through-wall"type boxes are not permitted.Provide 1.2 inch minimum (shout Wire,Three Phase,Grounded Wye System:For 120/208 volt systems,use one black,one red.one blue, spacing for outlets shown on opposite sides of a common wall.Provide acoustical potting compound on all outlet onewhite(neutral).For 277/480 volt systems,use one brown,one°ranee,one yellow and one gray(neutral). boxes. (3) Use wire with Insulation of required color.for sizes of wire,which may not be available In specified colors use Issue By Date&Issue Description By d)WIRING DEVICES self-adheske wap around,markers of solid colors to color code conductors. PERMIT SET 3.17.17 AW D Switches and Receptacles:Arrow Hart,Hubbell,Leviton,Pass&Seymour,m Slater. (41 Color code conductors at accessible locations. Ii)Wall Dimmers:Lutron. (S) Pull Rope Marking:Affix label identifying termination point at each end of pull rope. IIDOccupancy Sensors:Mytech,Novices,or Watt Stopper. vii)Disconnect Switches iv)Floor Boxes and Fittings: (1) Install disconnect switches shown mounted on walls at s4'-6'to centerline of switch. (l) Poke through type'.Wiremold Legrand. (2) Install disconnect switches shown on or adjacent to equipment on field fabricated galvanized steel frames. (2) Recessed flush floor box type:Steel Oty or Wiremold Legrand. viii)Panelboards v)hugstrip:Wiremold (1) Provide filler plates for unused spaces in panelboards. vi)Devlce and cover plate colors shall be as selected by Architect 12) Provide typed circuit directory in plastic holder for each branch dreult panelboard. e)SUPPORTS H)Motor Starters I)Support raceways on accepted types of wall brackets,specialty steel clips,or hangers,telling trapeze hangers,or 111 Install motor control equipment in accordance with manufacturer's instructions. malleable iron straps.Plumber's perforated straps are not permitted.Acceptable manufacturers brackets or hangers IDI Select and install heater elements In motor starters to match installed motor characteristics. are Kindort,Elcan,Binkley,Multi-Frame,Power-Strut,or Unistrut.Do not suspend raceways or equipment from other x Pull Una:Provide in each em conduit ext ways,steam,water,or other piping or ductwork,except as otherwise permitted.Provide Independent and secure 1 pry con pt sleeves and nipples;leave 8 Inches of slack at each outlet. support methods. xllFirestopping:Mould fi estopping around all pi es conduits,sleeves, which pass through rated walls,partitions q PANELBOARDS and doors. own a f Q$e�^ail Scale: NTS I)Acceptable Manufacturers:Cutter-Hammer/Westinghouse,General Electric.Siemens.or Square D/Groupe Schneider. END OF Menem 1�� I l`r66 24e36 li)AK Rating:Branch panelboards and overarmed protection devices shall have a minimum short circuit rating of 10,000 REVIEWED FORCODE RMS symmetrical amperes minimum Interrupting capacity(120/208V)or 14,000 RMS symmetrical amperes minimum Description:SPECIFICATIONS interruptingcapacity(277/480V). ROAM Rabin:Distribution panelboards and overcurcent protection devices shall have a minimum short Prod(rating of COMPLIANCE 42,000 RMS symmetrical amperes minimum interrupting capacity(120/208V)or 200,000 RMS symmetric&eres Project Name:VAIL BUS BARN PAINT BOOTH minimum interrupting capacity 1277/480V). /p� iv)Enciasures:Corrosion resistant gaHanized(zinc finished)sheet steel.Fronts shall be cold rolled steel,finish coated with Dates r �] ANSI 61 grey enamel over a rust inhibitor.Panel lacks shall be keyed alike. s 0)Doors:One piece bolt on frontrc with a lockable hinged door over the°vercuent protection devices. Project Number:201705 vi)Bus Bars:Silver plated aluminum or copper.Neutral bus shall be full size.Neutral bus shall be 21X56 rated when B Y v supplied from a double neutral feeder.Provide an equipment ground bus in each panelboard.In addition to the —31-; equipment ground bus,provide an isolated ground bus when supplied from a feeder which includes an Isolated grounding conductor. Code: O /1G. - Sheet No. E250 ,, PANEL RP5 PROJECT: TOV BUS WASH ENGINEER: SOH PROJECT #: 16063 VOLTAGE: 120/208V, 3P, 4W MOUNTING: EXISTING MAINS: 350A MCB TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION FILTRATION 500 20 1 1 2 1 20 0 SPARE FILTRATION 500 20 1 3 4 1 20 250 CO SYSTEM WASH 500 20 1 5 6 1 20 250 CO SYSTEM RECEPT 360 20 1 7 8 3 30 2407 WASH BAY RECEPT 360 20 1 9 10 2407 RECEPT 360 20 1 11 12 2407 " CHOP SAW 500 20 1 13 14 2 30 2500 WELDER FILTER 500 20 2 15 16 2500 500 17 18 2 50 4000 PLASMA CUTTER PANEL GP-1 10183 100 3 19 20 4000 11 11 10183 21 22 2 50 4000 RECEPT 11 10183 23 24 4000 " TIRE CAROUSEL 1083 15 3 25 26 3 20 1805 PUNCH MACHINE iwn 0f Vail ii 1083 27 28 1805 �IEWE® FOR CODE 1083 29 30 1805 MPLIANCE GRINDER 500 20 1 31 32 3 90 5796 MAU-2 fate: �� DRILL PRESS 500 20 2 33 34 5796 11500 35 36 5796 " 7 GRINDER 500 20 2 37 38 3 15 1083 TIRE CAROUSEL .ode: 500 39 40 1083 TIRE MACHINE 1500 20 1 41 42 1083 " LOAD CALCULATION SUMMARY ADDING TWO TIRE CAROUSELS AS HIGHLIGHTED. CALCULATED POWER FACTOR: 0.97 ,,, CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS ,�,,�''rao RE,�ls•- LIGHTING/CONTINUOUS 31550 87 39438 109 * Qoir,o H0 7 17 ' -% , RECEPTACLES 47713 132 28857 80 :u MECHANICAL 17388 57 21735 714 " KITCHEN 0 0 0 0s � `"�•` TOTAL 96651 276 90029 260 "=:'ssior. ' 3/15/2017