HomeMy WebLinkAboutDRB17-0555 Bus Shelter Approved Plans.pdf ..
-4,
. .
•
. 7
- ,
i \
• \ \
LEGAL DESCRIPTION
SECTION: 1 TOWNSHIP :5 RANGE 81 \
SE1/4NE1/4SE1/4PATENT \\\ mwav
#05-98-0035 GLO LOT 23 \ D
ept.W Wilk VdOfkS
1309 Elkftam Dme
ADDRESS: 999 VAIL VIEW DRIV: Vail,CO 81657
\\
d,970-479-2158
\ \\ \ .aipov.mm
•
N , ,
ZO
cc‘
O
vo It.
W
\ • J
W.
W
2
CO
1 N
/ :IF" _____. n >-
03 xi—
D W W
opo
, \ 0 cc
0.
lr ST 'P e::.4.1.,..._AP/R_____,,,c PP W_
1� // >
ill
Aid
•ROPOSED BUS SHELTER LDCATa
// ' 44' , /
\ .
LP
/ / / LP
/ / / TRO
Us
C DRAWING
\ \
/ 7 \\"\
: ;:
:' Na 11.5
(--P
L-2
>»
f
r
/ / i ,
1 , I I I '1 I / / / I ' ; ' 1 i ' I
/ I / i 1 i 1 1 1 I I / ) / i / 1 ' '
i / 1 / ) ' 1 I )
I / ) ) / / / / / / / I
i ( / / / 1 ) I / (
\ ( /
1 ) /
/ / /
1 / / ) / / / i1 /
II
1I/ 1309 Elkhorn Orme
I ( / / I \ / / / / Vail,CO 81657
/ 1 / / I ph.970-479-2158v.com
`\ / / / / 1 .aiWw.can
1 / / \`
\ \ ( ( / _____
) \ \\ \ I / N.,—.— --- ------.-.
/ / / /
\ 1\ \ I ( ."...."--- -----"'", "".......,.....
I 1 p�
I I \ X T N_ :f I _RS TO RIMA N W
°/
BUS STOP LTER, SEE PLANS �j V - --�
1 \/ W
I
\ / 2/ 1� THICK � D EDGE C❑NCRE SLAB ` N
I I ELE TION 8 %.60
) . %'. (9`p6b ‘'° ‘
/ 0.-1 .) 11NCRETE
:❑ APRON W
I I ---- — • ui
Q N
EXISTING ELECTRICAL( I I TRANSFORMER 12' W
I 8 DGE OF ROADWAY >
I J_
I a
I 1 4 / °/1\// LEVATION 5248.5
I _—
/ a:. - - ,
PE N REVIEW
I I ST'i,._ .' PROV TRO
I / DRAWING
) /1 rIATE ti J ' 0 T 1 1 - �/ 10/3/17
rovvoexo
47:
I / I / / 1" 10.
L-1
tOWIN OF A
HIGH DEF ASPHALT SHINGLES D'EI
44 4
STAFF AP-#L#A.: %t 1♦AN
♦ 1 .,_ eo...i.ti ..�;� ICE AND WEATHER SHIELD01/40 it/ I fC
.«
4�I- .,, �'iii `,N ``�� / r.!;-=; 2 X12 RS CEDAR ROOF DECK G • �'r �r
�r04r71�;- 9-` �� ."fri1� a i"X 8"LAG,TYPICAL 4,411"r
0�!n " t � ri THROUGHOUT SLY, ., ..,_.i:.
.rri
• B e o • B ,
4 X10 TOP BEAM 41t
8 X 12 COLUMN Dept.of Public Wale;
8 X 12 COLUMN 2 X 4 RS CEDAR TRIMVat CO 81657
DADO FOR LEXANg104¢
4 X 6 VERTICAL �� 2X RS CEDAR GLAZING STOP "'m
4 X 6 VERTICAL
8' A A ATRROUND LEXAN,ATIACH 12" C W/3"SS SCREWS
/ 1
1 1 X 6 RS CEDAR SIDING
CHANNEL LOCK _ _ _ I
1 i"CLEAR LEXAN PANEL,TYPICAL i"LEXAN
IeI II SEE BENCH DETAIL 3 OPENINGS EACH SIDE
9 o)4 X 10 BOTTOM BEAM • "�'
- 16" r i /2 4 X 6 VERTICAL
Al :4372 "X 12"ANCHOR ,� \ s��i
1 - „;:::;-,:v:::,-,;;;;:; .;,',:r'�z:.: % BOLT Yx.`. SCH 80 PVC
-\•„�.. - %,``„o%:`•'o,,,,.;o..;.;`.\;;;'o,. i”X 12 LAB BOLT W
4" JUNCTION BOX
THICKENED EDGE COUNTERSUNK 3" LEXAN GLAZING DETAIL J
2-6" — CONCRETE SLAB
4'CL 6 ROAD BASE 4 = 1 -0 W Cl)
ELEVATION - FRONT ELEVATION - SIDE N a
uj
= w •
0
WP ELECTRICAL OUTLET '` LIGHT FIXTURE 4 X 6 RAFTER CO Z
i"EMT
�� ` 4 X 6 RAFTER `� W Q
�` \ 1/2"X 12"LAG SCREW 0
�\� COUNTERSINK RAFTER O N
4X6 RAFTERS '` ONE EACH RAFTER OO
_ C X N ERG NKRAFEW ' p••`\ COUNTERSINK RAFTER ,l,�� 1 ��� ONE EACH COLUMN Q
•
A11:111
Ill
\ B 'Ail
4 X 10 BEAM Q W
RAFTER - BEAM CONNECTIONS CI -I
8X 12 COLUMN Z W
4ill H
N
4 X 10 BEAM
8 X 12 COLUMN
8X12 COLUMN
4 X6 RAFTERS 4 2 EACH BEAM REW
'�'� '�, OFFSET FOR CLEARANCE
3"ANGLE„2 PER COLUMN
-,.%:....
p.. .,...111!
. �, PAINT BLACK
- '+ 2 i"X 4"LAG PER ANGLE 4 X 10 BEAM J
ELEVATION - INTERIOR J }"X6"J-BOLT COLUMN - BEAM CONNECTIONS
P.1019,VI 2 PER ANGLE 1 n = 1'_o" 10/9/17
COLUMN - RAFTER/SLAB CONNECTIONS 4 `•rz
4 - l'-0" VARIES
SOU
A-2
I
1 X 6 RS CEDAR SIDING J'= urita
2' ( I •
12'
8 LE •NTYPICAL 9' rik.1.10-!1 OI OK if
CES _�� _;;, ;-- ,,
. _.._____/Ait
�� 8X12 COLUMN a ,� �i 8 X 12 COLUMN •
w ;A 0 1 BENCH SUPPORT BOLTED
a '- TO BOTTOM BEAM, - 4 X 10 TOP BEAM
o_ I `ll TYPICAL OF 3
L(.1 '� 0\ 4 X 12 BENCH SEAT 4 X 6 VERTICAL
Dept.et Wo
rts
Z 1309 Hawn Drive
o 4 X 10 BENCH BACK,.LAG TO Val,CD 81657
12' O - 13'-24" 4 X 6 INNER BEAM P'•90"'1193
VERTICALS,MITER ENDS TO FIT 4 �_ enw.wigw.mn
0 ae.
w COLUMNS i 4 X 10 BENCH BACK
w �� 1 t" DIUS -- LAG SCREW TO VERTICAL
w W1 "LEXAN TY ICAL
= 4 X 6 VERTICAL,TYPICAL OF 6 37" /
��
iM
SEE DETAIL FOR LEXAN INSTALLPiMil, 4X12 BENCH SEAT LAG
SCREW TO SUPPORTS
0 m �� 21" �• SUPPORT BRACKETS
v/ ° 1= MILL FROM SOLID RS
1 /11/1Wi■ CEDAR,LAG TO BEAM
PLAN - SECTION A-A PLAN - SECTION B-B BENCH DETAIL w
~
1/4" = 1'-O"
J
lig =
I-0" s" _ 1 �_O�� _
CO
n co
o w
w
SEE DETAIL -2 X 10 RS CEDAR ROOF DECK 0
HIGH DEF ASPHALT O Z
Niimimmiiiii -- +✓� SHINGLES , o d
ci
•
_i-<,`/44..4",,A. BITUTHANE ICE Q
SEE DETAIL 0 AND WEATHER 0
W:' •:..c•._•.; •liii
/� SHIELD / . Q
„ - ELECTRICAL OUTLET W/
::::1:T
2X 10 RS CEDAR �''ROOF DECK �`ll
4X 10 TOP BEAM45d LED LIGHT
MIN04 X 6 RAFTER
la
SCREWS EACH JOINT ,
RAFTER PLAN ROOF PLAN REFLECTED CEILING PLAN D0611,010
8„ = 1 '-un 8” - 1'-O " 8" = 1' -O" 10/9/17
UTE
VARIES
A-1