Loading...
HomeMy WebLinkAboutB17-0429 Approved Documents.pdf 75 South Frontage Road Construction West, TOWN OF VAIL B17-0429 Vail, CO 81657 Issued: 01/08/2018 TOWN of VAIL Office:970.479.2139 InspectionLine:970.479.2149 Property Information Address: 450 E LIONSHEAD CIRX(210106404030X)(210106404030) Unit#:X ParcelNumber: 210106404030 Legal Description: Subdivision:TREETOPS CONDO Unit:X Contacts ContactType: Applicant Full Name: PatrickScanlan Address: 205 Edwards Village Boulevard 205 Edwards Village Boulevard Suite E-205 Phone: 9709268703 Edwards,CO 81632 ContactType: PropertyOwner Full Name: JEWISH RESOURCE CENTER, Address: Phone: None Contractor Contractor Type: General Company: Alpine MountainBuilders Inc. State License#: Phone: 970-926-8703 Projectinformation ProjectName: Treetops Market2017 ProjectDescription: Tenantlmprovement of the main floorforthe Marketat Vail a grocerystore and a liquor store. Fees Paid Account#:001-0000.31111.00-Building PermitFee Fee Amount: $2,304.15 A ccount:001-0000.31123.00 Building Plan ReviewFee Fee Amount: $1,752.50 Account#: 110-0000.31060.00ConstructionUseTax Fee Fee Amount: $6,480.00 A ccountt: 110-0000.31133.00-Housing Fee-in-Lieu Fee Amount: $9,213.68 Account#:001-0000.31111.00-Mechanical PermitFee Fee Amount: $2,000.00 Accounit:001-0000.31123.00 Mechanical Plan ReviewFee Fee Amount: $500.00 Account#:001-0000.31111.00-Plumbing PermitFee Fee Amount: $1,500.00 Account#:001-0000.31123.00 Plumbing Plan ReviewFee Fee Amount: $375.00 Account#:001-0000.31128.00 Will Call Fee(Building Scope) Fee Amount: $5.00 Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) Fee Amount: $5.00 Accountt:001-0000.31128.00 Will Call Fee(Plumbing Scope) Fee Amount: $5.00 TotalPaid: $24,140.33 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within6 months from the date permitwas issued. If more than5 months elapses betweeninspections. Ifincorrectinformationis given on the applicationat the time the permitwas issued. //.. . ID. ChristopherJarecki - ChristopherJarecki-Townof Vail Building Official NOTICE: By issuance of this Permitthe applicantagrees to complywithall Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # B 17-0429 Date Printed: 01/08/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B17-0429 Status: Issued Permit Number: B17-0429 Date Started: 10/16/2017 Permit Type: Construction Subc ases Commercial Lot Number: 6 Property: 450 E LION SHEAD CIR X(210106404030 X)(210106404030) Contacts Contact Type: Applicant Company Name: Alpine Mountain Builders Full Name: Patrick Scanlan Address: 205 Edwards Village Boulevard 205 Edwards Village Boulevard Suite E-205 Edwards, CO 81632 Email: patrick@ambvail.com Contact Type: Property Owner Full Name: JEWISH RESOURCE CENTER, Address: Email: N/A Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $5,804.15 Plan Review 001-0000.31123.00 $2,627.50 Construction Tax 110-0000.31060.00 $6,480.00 Housing Fee-in-Lieu 110-0000.31133.00 $9,213.68 Will Call Fee 001-0000.31128.00 $15.00 Payment Information Date Paid Payment Type Amount Plan Review 10/17/2017 Credit Card $2,627.50 Paid By: -N otes:Visa-Patrick H Scanlan Construction Tax 01/08/2018 Check $6,480.00 Paid By:Alpine Mountain Builders Inc.-N otes:ch#36638 Housing Fee-in-Lieu 01/08/2018 Check $9,213.68 Paid By:Alpine Mountain Builders Inc.-N otes:ch#36638 Permit Fee 01/08/2018 Check $5,804.15 Paid By:Alpine Mountain Builders Inc.-N otes:ch#36638 Will Call Fee 01/08/2018 Check $15.00 Paid By:Alpine Mountain Builders Inc.-N otes:ch#36638 FEE TOTAL $24,140.33 AMOUNT PAID $24,140.33 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 01/08/2018 -2:21:44 PM-Generated by:cgodfrey 1/ 1 MICHAEL HAZARD ASSOC LAT ES ARCHITECTURE PLANNING INTERIORS November 7, 2017 The Market at Vail ProjectDox B 17-0429 11/1/2017 Permit Review Comment Responses Drawing Revision 1 Sheet A0.0 The application for a change to approved Design Review drawings ha been submitted. Sheet A0.1 Comment B001: The existing stair and ramp do not comply with current code with regard to rise/run, slope and minimum width. Given that the existing floor structure cannot be modified to attain a compliant slope so the drawings have been revised to eliminate the ramp and replace it with a wider, code compliant stair. Please refer to sheet A4.0 for an enlarged plan and section through the proposed stair. This is not a required path of egress. Comment B001: The note incorrectly references that the Second Floor which is over 3,000 square feet. The Third totals 2,621 square feet.The correction has been made to this statement as follows: PER IBC 1104.4.1 THE THIRD FLOOR IS UNDER 3,000 S.F. AND DOES NOT NEED TO PROVIDE ACCESSIBILITY. Comment B002: The diagonal distance has been revised to 122'- 9 3/4"and the corresponding note has been revised to the new calculated minimum distance of separation changed to 41'-0" Comment B003: The code reference was corrected to read 1010.1.4.2 Power Operated Doors. Sheet A2.2 Comment B001: A copy of the proposed point of sale casework has been attached to demonstrate accessibility compliance with IBC Section 1109.12.2 Sheet A2.3 Although the referenced bathroom is located on the third floor where accessibility standards do not have to be met,revisions have been made to be compliant. Comment B001: P.O.Box 1068 VAIL,COLORADO 81658 970.949.4958 P 970.376.0066 C MHA@VAIL.N ET MICHAEL HAZARD ASSOCIATES ARCHITECTURE PLANNING INTERIORS The door schedule has been made legible where you will find that Door Tag 5 clarifies that all such doors are fitted with a latch and closer as noted. Comment B002: The demising wall,separating Rooms UL 105 & 105 has been eliminated to allow for the requisite space (60" x 56") at the W.C.to existing with no incursion from the door swing. The Hardware Schedule on Sheet A5.0 identifies the necessary closer hardware. Sheet A4.1 Comment B001: Full accessibility details have been included on the revised sheet. Sheet A5.0 Comment B001: The Hardware schedule has been rendered legible. II P.O.BOx 1068 VAIL,COLORADO 81658 970.949.4958 P 970.376.0066 C MHA@VAIL.NET MICHAEL HAZARD ASSOC IAT ES ARCHITECTURE PLANNING INTERIORS November 17, 2017 The Market at Vail ProjectDox B 17-0429 11/14/2017 Permit Review Comment Responses Drawing Revision 2 Sheet A0.1 The reference under Accessibility Requirements has been revised to read "...accessible route". In your comments on sheet A2.2 regarding "...means of egress path;paths of travel diagonal distances,maximum path of travels, etc." please refer to the Second and Third Floor Code Summary Plans. Sheet A2.1: Please see that the existing egress door has been re-tagged as Door 8 where the existing door is to be fitted with new panic hardware compliant with the assembly occupancy load requirements. The schedule on page A5.0 has similarly been revised. Sheet A2.2 The check out station at the liquor store has been noted to comply with IBC Section 1109.12.2. Please refer to sheet A4.2 for the requested check out station casework elevation. Sheet A2.3 The plans and elevations have been revised,both on this sheet and sheet A4.2 to reflect this oversight. Please see that the existing egress door has been re-tagged as Door 8 where the existing door is to be fitted with new panic hardware compliant with the assembly occupancy load requirements. The schedule on page A5.0 has similarly been revised Sheet A4.2 Please note the revisions to interior bathroom elevations to address the proper placement of the vertical grab bars Sheet A5.0 Comment B001: The Hardware schedule has been revised to add Door Tag 8 for replacement of existing door hardware with the requisite panic bar hardware. Sheet E1.1 The earlier plan had incorrectly indicated exit signs at the Loading Dock which is not a designated path of egress. The plan has been revised to properly designate exit signs at the rear sign (between Col. Lines D & E/# &4). Please P.o.Box 1068 VAIL,COLORADO 81658 970.949.4958 P 970.376.0066 C MHA@VAIL.N ET MICHAEL HAZARD ASSOCIATES ARCHITECTURE PLANNING refer to Sheet A0.1 for Second and Third Floor Code Summary Plans.The INTERIORS duplicate page has been eliminated Sheet E1.2 All sheets are stamped&signed; corrections noted &revised Sheet E2.2 Corrections noted &revised , II P.o.Box 1068 VAIL,COLORADO 81658 970.949.4958 P 970.376.0066 C MHA@VAIL.NET , k %Orin u.,,,,.—o r LS918 OCR,110100'EVA / -10 A -0 3 )113 CIVRHSMOI1 isva 0E4 „v. -r-_ • iopliPVI ...u!-sual4.1a v i.p..q.v,1 ii:HViie 'mil`s.roaum l2ug Sunsuop u.100£1 gc.:, : /I 'II Iv JamiviAl am. ,.t tt_ 0, j ...,'d i.i n t -, '' iiinc',1 1 'I 8 hh g I g g g i 8 88h § ' 'higilil 8X g 2 5 HI : !, M!iEiVAHhEEEL! b In 1 2 ?, iir ill! i.:.,i1AliHnlithli0,111 !! il II ii II ii II ii c'''' ! tcIl cl § 22EEgIgEIgIgE § Ig ,, Pm ; B5 ,ii Orom ! l ! m !m hEL . . . . _ ._ 4 888 988898889 i 8 888 8 2I0: P ' 1 0 i 1 A.e,-i 1 A9-A.., 7 .2g4 : , , W,3 . E-',' E MIAP,39. 9--0,..--,9--h ..--hhh,19--hA9--,10.`Hi HH HH II H II IIINII < LckjzI ,T-'6,'L '8 .1N ,`' 2zE LA oim8.8888888.8q 8 0 5 .,-77-... 0 -,k-,2)— a ig4'4. di : 2 8 g 2 :1 2 0, .L., 0 i .HM88222281 t% `313.mN 3 S, - - 2 R $ •,4 E v.v,7 L.,- -- . 1 - § - 8hhhhhhhhghio i FIUHITUI. 1 W 0,,e v\ivv ' . ! qiiIHIEHIIIIIIILOz -°- °--4 iiiF 2 2 - n`NY\A = Ili 222 2 i ggg 209999999992 " =I- M ,$ § § § 9.0404 ! 0 ! ':'' ''l 11 l'' l' l' 'j t• '05 "il', N tifihniMb i g H g2 2 ' ' ' - g 05 g, - g 7 5 ci' 5 0 P 2 55.288 '' i n988222222 4S8.2 E E 948888 28 =! 1 —,4g 9HT21 ! I. g i i i L -, . .ii i ilfl llgi H git cc ii,c ii W Gg 5'Sh AO § gg I±1 jib: AAAAAAAAA „.,1 2222 LLAjill c n sI c Le 04 il= . v ,,,. 22222 igia L. T;h,P , q2, 22, 2222hgligiii z,82i, w — .. . .. , , 1 0888 E. i:L— . . . . . , . 0.hp, I hp, i Ag,i i 5:1-A..25.._-A..25282 118. 11 2 p.,_ §7.H.,,,.,,,,.,...••. -" """ n"" ,, L', 0_§7 m:-.7,.-_-::->,-,,-.> 2 Lit -:“...,:.',...,..:.—•,..',..,:.' .e 2 5 Em [LIS. ' a;,, gH.7 ,7 ;' "g' R 5 ni 4 h, h h h 0 .1 ',`, '.'7,i...T.,.h..h.h 26 v.; .0...er.. 81 81 hi LU i, 02. I'II L° 1 02,- -I5I_ 1- 88888 < , 888 . 8 . 88 . - - -< ° gin-.F..W.,`,,,..,P A LA A 0 dn.t;•.?4.s ' - 9 ' EE ! Z 1. ; 2 A RH-1 r�1 COOK TRE DATE: Extruded Relief or Intake Ventilator PROJECT: LOCATION: Throat Width + 11-3/4" - Throat Length + 11-3/4" 1 of 1,I: _ilL,IL,_ A __ / k A FleightAinlik A 4111111k --2-3/4" Throat Width 2-3/4"---- —2-3/4" Throat Length 2-3/4"--- STANDARD -3/4"--STANDARD CONSTRUCTION FEATURES: Heavy gauge all aluminum construction — Birdscreen — Solid welded ACCESSORIES and mitered tier corners with a built in rain catch on each tier — 1. INSECT SCREEN Built in water trough — Welded curb cap corners — Anti—condensate 2. WASHABLE FILTERS coating on underneath side of topcap — Five year warranty. 3. GRAVITY BACKDRAFT DAMPER NOTES: 4. MOTORIZED BACKDRAFT DAMPER 1) Backdraft damper 1—1 2" larger than throat length 5. GRAVITYOORIINTAKE DAMPER P / 9 9 6. MOTORIZED INTAKE DAMPER and throat width. Mount in throat of TRE. On TRE 7. RCG GALVANIZED ROOF CURB intake units with less than 6 tiers or TRE intake 8. RCA ALUMINUM ROOF CURB units with 2" filters. A backdraft damper 1/2" 9. ALUMINUM BIRDSCREEN smaller than throat length and throat width must 10. LORENIZED FAN FINISH be installed in a curb with tray. 11. KNOCKED DOWN UNITS 2) Maximum size of TRE without being special knockdown 12. SPECIAL type is 75 X 179 X 12. 3) Curb dimensions are calculated by adding 4" to the throat width and throat length. 4) Maximum knockdown unit to be determined by factory. THROAT HOOD QTY MARK SIZE SIZE HEIGHT THROAT PRESSURE CFM ACCESSORIES VELOCITY DROP LXW LXW H 34"x34" 46"x46" 16" GV003R03 F./Cr. Sales Quotation v v 2Xuata Humber. Q115 7 a21s4el Vete: August 31.2417 [uatl.Epiralbm November 29.2017 6151140Th Are I'M Rimcirpr MM 55343- 501 Rhanet976,709-3733Fow7633SIB;B S Prep:nrdby, Ryan dodo Oommes,lmoarrts 11661 firaparsrd fen ASSOL:lr1TED WMOLEiA143 OCCAS(NORFOLK.N AVID STOnE ENGINEERING Pi rJec[Rear arae 13314M4 r;aeFOLx,Nr,E The Market at Vail-Vail,Colorado sgfWga • Sates Ilep; RET EQUIP 933-583-3253 Pal;SenETer.11e: Carrier p r d'. .i.-. I ircry crags: Kok WINO Bart Way Ramury,MN Prepaid$S Add quxa an Hato: 1}AJI C0ST/EEGik whim a Ifiel+iduil Imp branch cirwIt 1±4ISSIon mllei#Iliiped1OUsrt ler field n5LY1;3E1Gal- •7}MI LTC Lenperetrre g deFrosk tr.-miriade',sensors by xhei", 3i All CPC 603ICStar Bemperam it 8 derrase Mffnln3Tibn moriloring,L174CiFFYRv.lrr and dnfrcst metro.bc.31,to 3-a 'd In RcrnOLC Dofrcei Panel(.7P}. 4},411c1“ancde$O[keeen onentsfortirrcla14i-ItlkotoinADP 5i All Laseark walk-1i eapp #tarlanr.11aI1.L anka.swcacs,and assoclame mmP'1c1 s Powcmc byc 3-3, q.rorrernngpr posmeTif from 1-$3r2pn!al EYge Lal[. 7}11QP per,r dfrom separa!t 2Qe-73q+3.66powgrsqurec- PlMaur wemourned ckri r pvtiorcti(+wn,rdgeunitmainpower, 4}Ilwo.hnnr 3-6 liquid e3-er to be Old aoudad co der 1lr Fi fstbtre. _19pCetnicrascir impaEity.IiDadfrtt dfarelcv�i�gn, li}CPC F5110p ci rtrober airier]. curiiKured ID be mm.ln+ed at the E0me unf. May ba rebated to PDP, iamian to be rmrlfirmed prier In 6na1 nrIAirtnrr.np. 12)Eddaurrt 11 RLI WhIllpir_dttrrnd![10K S{CR.Arlin!requirements TRU.Pricingad}rst required for increased SECT orAIC (ulna[. 13)51reelafy'!st ehaei3-ie[erYnst LWSd considered iCthti for ALS'111:A24 MUM n eulaElons. 1d)Sys tem nridngdcu ntIrvluderer mleeerlikatlorre, seismic requErrmentsltlp. Ser Arfo..11M!AMR oflawn def Frahm{.Dort ton and Croat Sdrreh1er System Cross Deurrptlon 5naAt[xhrrdS4fieclolal City Horizontal Edge:R4411A SAW Temp,4 Carrrpressor3 2 Ci•Cults 1 Receiver Skid(faartary Mounted Balm E xideraer) k Renate L7errast Panel!ROM f 5ysterr.Total $ Mir Condenter Group D eserrptIon{deeAttached Scllede _ City ▪EINhDP.-A03f JI Comicrtser TUtaI Qtkcr It4rn3 GrOu- _Pe3c4E1011 CM, Tonal REMOTE ALARM PANEL W/STROBE _ 1 4 V EXTENSION OF COMPVIIARRAt4TY 1 Otho!items Teti) $ Total "re' L r&rksr seeaf+aor4r! d oppi.r,lkis oictirriort L7t7E NOT rtroirt Lux i freght. Tilts ib.W.V.0,nr1snuG.'eiiit,the Teem.t.r5rJered O.aeYea?Unarm'S4amm[yfl3Aasreda3-4LWYl.x!F EDReCRAF d. orquaintrISrtimedogidruSquoertiDetciontartl42arrrepersrnrINre.,grrfiltoped923-ti 3-3353dryore•Zerodoir.Are.surerrrginerrAycnAorira:a 72.2- 3735, Sales Quotation • Quote Number. Q115237 6151140th Ave NW Quote Date: 08/31/17 Ramsey,MN 55303-4501 Phone:763-398-1996 Fax:763-398-1998 This quotation will expire on: 11/29/17 Clarifications 1. Zero Zone Refrigeration is not responsible for the overall design of this project and will only be responsible for the design of our equipment based on the information provided. Any unseen or unmentioned requirements may require re-engineering and adjustment to the price. A pre-manufacturing meeting with the Installation contractors,customer,and any consultants will be required to review the specifications and requirements. Any changes made at this meeting may change the price and change product lead times. 2. Zero Zone Refrigeration recommends that all machine rooms and occupied spaces with the potential for a refrigerant leak be equipped with safeties and shutdowns per ASHRAE 15 guidelines. 3. Zero Zone Refrigeration will provide a programmed and functioning control system for the refrigeration equipment listed In this quotation. It is the responsibility of the owner's maintenance representative to make adjustments to set-points and defrost schedules to achieve optimum performance of the equipment. Interface of the refrigeration control system with any other equipment or building control systems is NOT included in the Zero Zone Refrigeration quoted price. 4. Pump down capacity of receivers listed In the configured features for all racks have been sized based on nominal ratings per system horsepower. Other system characteristics may affect amount of receiver pump down capacity required. Contact your Zero Zone representative if additional receiver capacity is required. 5. Approximate product lead time for equipment is as follows. Contact your Zero Zone Representative for current lead times. a. Single Supermarket Rack: 10-12 b. OPS and Multiple Rack Systems: 10-12 c. ColdLoop Systems: 12-14 d. Mechanical Centers: 12-14 e. industrial Systems: 12-14 o Product Lead Time Is defined as: Product Lead Time begins when all information required for manufacturing(outside of ZZR control) has been received through product completion(Does not include shipping time). o Shorter lead times are always available at an additional cost—The additional cost for shorter lead times will reflect overtime labor charges and any cost associated with expediting material to meet deadlines. o Change orders usually affect product lead times and the quoted price. o Projects requiring custom materials such as custom liquid receivers,are subject to the manufacturing lead times of our suppliers. Custom materials may lengthen product lead time as stated above. 6. Air Cooled Condensers and Walk-In Evaporator coil pricing is contingent on a joint rack purchase order. Condenser or coils sold separately may require a pricing adjustment. 7. Tax,refrigerant,crane/rigging/setting and freight are not provided. All quoted freight amounts are estimates only and are subject to change. Condenser Schedule 8/30/2017 8 17 Quote Number. Q115237 6151 140th Ave NW Order Number: Ramsey,MN 55303-4501 Project: Vail,CO Phone:763-398-1996 Fax:763-398-1998 Line No Description 3 Condenser.k BNHD04-A034 Features Fins per Inch:10 Fan Speed:1140 Control Manufacturer:CPC Fan Control Method:Per Fan Refrigerant:R448A µw� THR:265.39 Height On):49.13 Length(in):127 Width(In):88 Dry Weight(lbs):1440 Oper.Weight(lbs):1680 MOPD:45 Fan Voltage:208-230/3/60 Control Power:208V Control Power Source:Fed From Main-No Cont.Power Xfmr Fan Overcurrent Devices:Breakers Contactor Set-up:Per Fan Control Strategy:Control Board(s)Installed Non-Fused DisconnectOvercurrent Device Set-Up:Per Fan Enclosure:Standard Condenser Model:BNH-D04-A034 TD:9.89 SalesDescription:A:BNHD04-A034 Split ConflguratIon:50/50 thrlar2017 Remote Rod7up CundE nsa-13 irrHnsirorm.ipg :.•• • -•.:.',.,"4. 1A,:”•,rrnq:..:.•:-,71T2V.qZ::-:. .:-!::::;•4,,W;.;:-•:-::-::igi4driziERL!'tiMplitatiege I; .;:. - . .;:g':-,:..R>., -,%-ve:'L',1,=.r:A..::::•fo.:',twaggii:;, ,Mie!•:.;akipointinimizatotom .!;:;!;v: .•: •• •. :::2.y,.:,:,;:rtnesf.:T4,- 7..4.,%;;:":-.::t;4.epitunit.:•:::!: •:•f :•,:vma.:10._;:cairviostsoma :::::iLF,Kis:;. CONDENSER Di MENS1ONS EpdVicarRu Sin Row 49f Fans DatiA-:Row o4 t•-ailEr; 11_,—.---rs.: : r .. • 111001001 1 ' 1:••.•--•-•-••••••'d:Fli&Ilii 41 4 I; I . • ._._. . . .,_ ___.. ... , . . . .. •' .1 ..._ . .073 M.MITA 1.-If'rtiEve', _Noe A Ok.1...0an — -- —-- -----.....—.----...... Side triff,45 - - - 71 —1 T gip------. LAIN PUDIRI i*IR R.INI IIi 1 ;•4: 1 •1111111. Ell Lii.o.:•5 _/. ' • .•• . X 3 2 x 3 1-:----la.— . S• -:, F. 53—.1 -ni- 6..gar FLIradC 1 x 2 SAW .1.1NT . ... . ... • 1r411.116167' i . . , , ... .... ,• • •Fmimiimmai- :1- 1 ' . . 111 1 • I x 4 • _INN= rii 2 K 4 .--InEs— . . .- • mc ei/gm FLiPill 1 . 1MI1! !: 111.11.11. MI i • 2. x.5 ni al-p. -,i...=mei isommost. oramiwromain., . . ! . ---4-- , -1, .4; I1-•—,741. rIL n21—.-dmi B2—.1.--53,,,,,---,—.-53--.1.--,0-4 f p--._-- ,N:4—••.-- 9•4 / . . ..' JURIPLOW II RANIMBEsunt „mom. T. ,.... . . .i. ., „.__. .... • 1 1 1 ..: , . .1_ i iii ' , mg-ri .. ............... ......_._,Hr 3g hirWirgailigoogfe.cornintallinamCraiteardbirri ikEr2Projecti=1 trf miiiINV Allimi.j3CE1111..1TH DISTRIBUTED SYSTEMS _ ...... ..... .. - .....,„:,-„.:: •._ .:-..,=r:. . . .•. • Higher Hor--,eriower •• l'• _ .._. ... .. -... . . . . .. .. •, • ,.,-,,,,§:• .........^.1.417U• • Greater Flex:DI:1,y :• : ..• -,,.7%•_.,.--,••• s.?.z,c,••,e::9r1:9...i.;•.•,• u...,.,......:..,..„,:ww,,,,.::. ..• • . . . . .,.: • • -••';;,,--';4•Aii•$skiri:::.:‘.; uperior Accessibility •• . . . • •• ,,.:{;.:...::20.:::siztL4.4...i.{. ':'' •6:L% 1.'it-••• "•':'''•":r...„. ,:.:• .. .:::•*',*••::'.:3'.•:'' ...X ' • . • . : •• . . ; •••'4'•-:et. •••••••:.'%• . . . - -. :.:. • . • .•• ....,.•f'',}.....;: :,.LT.:RA..... '•ii::r.e...I1-.:;!;.;.&•.. .. 1-1 .:.:0 * • • . • . • V.':.4%::.gUr740.1 • .i.7 :. ... : ''.' • tliklr.r.1:rrr F-41:111 .• . • . • ' - "-••••A:v:..t.; .31:y ••• ••.•:%•.-••?..,•e:•.:z4,:agq:.:.....- .... • ,'.':''•:.':8;;;A:Ert•tir4...1:,•E'r ..v . • . "x•':• •:'...:.?':fiNP41:V. ". . • :.::•E:::g••••'•:::i:*4.A:2.1;" . '; t• ..-; A. It .1•1: r.!. .. . . ••• • !:- ,r,:;• r '.3 ,•j • ..::::%;11.i.444.1:1tiiit •'. ••r • ;Mt'•':;:;::•H-4. .....,..11.1: ..., • : :..,::: .94 ten:M•gA::::..;:: .. •:.:::g::•::::•:::::.:g07.•5:!4:i:V.: :.':• : • 9— . . ..._ 61...E;:.....5:!....:.....•••-'*'' • •tg;:i4.404.:• • Ng}.•%xi:,. :,:r:::kg-• • • • • . • •.,- '‹•,••••,..•:::•-,:.::::4.::'•.,;•.,.:.:••..•.-v%••.. . '":•.,• ' -.•..........m-05'55-•••••.'•'-:.0•'''.' !..:.'n .... .. . • ••.• ... . . e .. • • . . . . :• .• • • •• . . .:•::••••:.g...•:— • •1. •:- :::. Z. .‘C,..:It.,1 ...:..7.. i . •—: .41r• ee 4: • e .. • — ....!to.. ig .,...?.....:. •Ailliwo: •!:.i. . ,..-..*• •:,•-?.r.'••• ' •• • • ., •ii .,..•• • • i ....„ . . •- •i •:.:••- •• .. . • • .4:.0.4:Z:. ....._.'Img;.. • .• • . . . • • • • .....•......:.Kisti -4....,••:•:.:•...-•.•••••••:••••••••,f•..- • is,,L'. --. . .... • •' • :!.•:Atti: ••• •'••••:4:4::.:•:60:4.ft:'•• ' • • • . . • • . • ... • • . • • . . . '% -. . . . . . •' • . . . . . . . . . • • • . . . • • • • • .. . . • • . ': ..:::.::•..::...::N.:,....{..:....zed....::.:....:2::..{.•.{?:-•:$2•:•.::::.::::.:::.: .. • •• . ". .•.......!•44.4{.4{:}} .,....:,;.j...;;;;0;s:i9:Re9Y-*.',.:+44-:::•::::::::;.•:••• ... . . • •. • • •.•.•...:•......::.:•:. .. •;:;.... ....94:!..: •:-:••:-y-:•:'...•,:: • -......-.: .-..••::-5 . . . • .- . . • . • •- • 11:!:F::::• - •• . .......... ••••• • ..... • " . " ::"". : .............:;.........:• •-...•i:,•:.::::::....:::.:::::::::: :::.:::::;..::: ••-•:.•:::::::.21J:;:..ag::0;:- "''..:;% ••!„....-•:7•••••••7: :.:', .•'...':.<!;*:::in•:•:::•:. .. : .:: ::•••••••••:- •:.:-• ..... ..............:..:..•;:.-::,:n:.:•-;:::.:::::::.t.::::::::g:C::::::::::::::::•24;g4kU:::::g:::::4.:...:-T .....,.. .-.•••••!,.',..:::.-,•:.:4:::..;::,K,Tft.,.,;:•;-.;;....:;..:j,....ci...,i,..i:::::!•::::.: ::::::::. .. .. . . . ... 1••••• : •••••••• . :..:...:.....•7• -••••••.::: •••••.:•.:••f::•:••t;ZE.:ii•:::::•;-..•-::-..:.:'.::::::::':::::.::::.:!::•T:i.E!:-:;:!.::: ::!..:2::!:!:.0..N..:V....2.:k0.::.::::•:.:4;‘.;••••••:.::•TT.::::.•••••-..............- • - .f. •........—• •-•-----••.....-.......:.....:•••••:::',":•:"..•;:•::::,--•::::;::::i.:.:6sk.:..;:!griWi.gMingffidggg:iaig4:MA;fi;i•••.;::gi....:.: '..:.: .:..:•.:::%:.::::.:•••••,:••:..:.-.•-f•.....::.:::. ;.,:-:.:::::.;.. . :. • . ••"::•••-:..-:-.--:..........:::?::::;:.:•::::::;;Z::a?::•:'•;?::;.:q:::::".a:4::E.:•::::::!,:z:•;:•;;;::::::::.:;.:•i:•:;:•••"::•:•E':•E'f:.:'•::::!:': ::•:•:::•:::.::.;:.::.;:.::.7..::;:i...:.:i:i.;;;.••::?•":.•::::::: ::,0::•44:. :::::•:: .•:••••••:.:0J:.:i.:t.::.::-.x•A:t1::::::.::::Kg.;;;;;;;::;:;-:•::::;:::,,:,,....•••:•::::.-:-. . • ••••::-.•:••••-•-•...:.:•:..... •••••:-.•:•••:::-....k•-•"-::::•:-.•.........:. •:•••••:-..5-•........':........................................................................................................................................... • • - • Tiiiiirtiiiiii:AU.:: 1404r.q:::Tig:•gitTE.ps:•::-...:.::ex-m:-:,:c•:•:-:0:9•0:-....:primpeo,..2..;::.:.•,. . . • • ,,146rifkijk:**.ffflP.:30c.4#:•:-.:•:;-.•::=i,::::.:.:::4•.:::4i,::::„:::::,:.„:::gilli.:.2:•..gomayt: . . • • . • • • . • • ..,:rf.iref.i:Dp::.mr! ..._.::.:•••-.?• .........:,.: .L.._i,tr:-.1s4...,:...... ...= ran....#1,...t.•) • • ' •' -•=114tegitEZIOr..:.41.1.13,-.S-.'4Nik'•Mi.,.,,,...,....w.:.• ., ... ...-1.41.r.:.:.::!..:.. • . •. • . .%.71,:17.^....9.,... .::..#:..........,-.- ,. •.....i.:g4iiiiikAMMI:;.:7•••••••••••''. ''•"•'"''.•• •." • :' . .. . : • .,.. ,:...„:-....:1;!.i.,:.hril:H.I',Ffi P.r.-F,."..50‹.k::::!••••:PI:.......-?-h:.""P::,:4:.:.:14•-•;:i...ii::. ,-.....:•.. • ' • . . • • •• • • .• . • • e i''•t'i".‘i.r.ridilketliiit.NOM:.1•041. ••- .. ..,. .. : ... ., . ..... . ' • • . . . •• • '' • •'' • . ":.- • :::.:.•.:‘:':;:'.;.:.:•7.1:;;:•••5 F••••••••••••••.:•••:•E :t.:.4.•'.•!.:;..:......;.:....::...... ..................:...... ...................:::::. . .. . . ... • . • . • • . . . .. • • • ••• • •• . . • . . '.' ''.' . :: ::!:':':'.: • ....-.... ... . . . .. .. . • ........i....i::::. .•••••••;a;:::.:. : . . .... •• •••• • ... • • - , %. DISTRFBUT-E S1'ST ; �" Standard Op#hnnaI 'AIMSEViNii:;i:M"0,:,44NA:JEAM:i: .'•:i5ySliejiki:ft a Combnatnnarupis8=orpresscrs a kinculnbogIaie,,ri1:vCrJll LCN.romp; corn isersurs `: 2 • • 2 to L3 HP Serpi 4 Index uldoeder;fro s . i r w-, Y :; :. r „ ' 3 b 6 HP Serpi-HerrnG'it #err:.harr'nc,ics ''•• '' r.lcdium TIS•k • I-3c3d rodinq Fans for !•:. ' ••• r ; ■ 2 to 13 HP Scrd1 smrri-herrn/3 im • $to HP5oml-Haim a YCChen.Cal sub-Cader } ::. . • { i •rt Llqu iij=ii7'1 sarnpencnla far 44 scrolls comparranb gar law VIM ' f# s . . ,:}` , u VaparIn]atian:orr:Ronc'i sforl{V scrolls ss t-her ia-A se's' 15 g: . • ��:::.. +� 5 .::; .. ti `} (Ir�cmiltigsa,o63,,..lparle'IIS] .:":::,-14 ' ':;•11;:7—,'': e Cra'rktu5e real ;*w • Modular denial{acomprc ols • ScrAre IIghlliv and 1104 :.:4,:#;:: prnoXvItil •3FCrcomrenierxeaudel °' n Melded steel base arc fren'e e Powered va tilallnti • ¢ v Drip pc4ti{'n main] . : , y-- .. _ .. s Hcged ars moth pneunaato aG:slor3 •' °`$ , m L7ral'I Fronk panels .. ° , I+ Eeurd elani ngne kelulaei I. • ''.1'.-. i °. ':, a.v. ..:::s rr VIbre1lon isUI34ion pada tti':: 1': •M1 zr..1;:::.•: "•a [sh: ped looso} ';y`e`a .-•'' , p d5«:.:M1 'I.=::::3:•::i :M1:. :::.., SLAM airl.m lntar e&::' I r� 5ier�'�fl bC�tle! i I rr :}. .. +i. a i}7 t Ci PrWttI.ie!rr ka911IY.et {#hi�j'JhYI 1'fYUl) •r':'... `, !.: -. .▪ r el RlapFan decree slnctcn 9rer • Spill 5lxten header k r ..v �r ;? ■ JJ In6tll7tPr i . }.-_{ -.' 3PI4 fuCtbl�Cr36i DM s'rc ' ■ Lmp piping with leofalicn..rakee Scra]I Carnptel rs Jwaileb�e Up to 13 I-11=1N U ■ FraM et.tiads oi:cGic I WO a ualnoszon- l sw,c' v . r► Microproomsa rack eanta1Ic (r'arnle Har-`rsmr fJsod,or ....�'•" rnaunletl) C#C,■1brs9l4er ..a. . ..,. .w # 91� al a d�nlyulF�n Rand x VO boards r e ".. ..':.. x : a {;c+npressw Gupta l r use swrxt ■31m. • • y , i ▪ :: • Compressor car a3=5 3 1d 'arm,a,d.'ar I Jag ° ":, .""' -..4.--."-:1;?..-.-. F xJ , , clown.tB9kers$ r • } _ # ;s wi o PvRcrrmh.,,r. an bi,.. ^_iM1. ■ Condo ,r,.. cirrJrttreaker . .,n b Phase rrlonkar ;, N," Y x a Elect1ecefresi pal'lae require & _ ; x::.:x . „••, klei 54. ;O'er Reciprocating Semi-Hermetic "—""'lat' Jx .zc "" - COMpreS5+or5 Q4 :' $ Available up to 9 HP '. ,.- ,.,., : • : 1 : ii. } x • • t n k}a.i %•..x' • • • I „—........w.wxwvaayv.._...h1... .. ... F : ..._._._._.............._�{rSGt'.,�..��„�..�.. €W�...-_._:fit.._._.-�., r } y,:M1y�Mg:x l';':.';.1%. � .:;:" „::',.zr #eco- : <a:::} * " �ir ?'.. ', & .. .ry •iN :: :a . 'pry N{ : cxm« :, 't ElIF us- rVaY iMaxqtr.wS z- • iretertek . : t 2012 Zero Zor , r. 'Ir .•• Sl.-O9:1 .. EE RLIA{;;Y 2! 2 . .: . ' . °:': W i n o n a LED Project: Qty: Type: winline surface linear 207W/209W/211Wwet I; Winline SurfaceLinear Wet-WSL207W `I, Winline SurfaceLinear Wet-WSL209W Winline SurfaceLinear Wet-WSL211W series .fes Linear Center Balance-LCB �, Linear Longest Possible-LLP Linear Same Length-LSL linear plan TotalRun Length 48 200FMC�1I offered in 6"incrementsstartingat 12" ex.20FT6=20FT 61N run length See page 3 formaximum run lengths II 1ft section length-MSL1 48 200ADJ \;�I� 1ft 6in section length-MSL1/6 2ft section length-MSL2 maximum Th eWinline 200 Series are small scale linear LED luminaires designed to be the 2ft 6in section length-MSL2/6 section most powerful,reliable,and easiest to implement linear LED solution available.The 3ftsection length-MSL3 length model WSL207W/209W/211W is a high performance luminaire suitable for exterior 3ft6in section length-MSL3/6 illumination. 4ft section length-MSL4 Beam Spreads:Winline WSL207W/209W/211W is available in beam spreads of adjustable mount(200 series)-200ADJ 15, 30,60 and 100 degrees.See page 6 for photometric data. fixed mount(200 series)-200FMC mounting Color&Light Output:Th e200 Series utilizes Nich is 757 wh iteLEDs in four accessory standard color temperatures.Model WSL207W/209W/211W features(16)LEDs/ft. - 15 degrees-15DEG 200 Series Model WSL207W Model WSL209W Model WSL211W 30 degrees-30DEG Color Temperature Im/ft W/ft Im/ft W/ft Im/ft W/ft 60 degrees-60DEG distribution ANSI-2700K White 120 3.2 240 6.2 480 12.2 100 degrees-100DEG ANSI-3000KWhite 141 3.2 282 6.2 565 12.2 ANSI-3500KWhite 147 3.2 294 6.2 588 12.2 (WSL207W)LED Linear 4 -LLP 4A (ANSI-4000KWhite 157 3.2 314 6.2 628 12.2 (WSL209W)LED Linear 5 -LLP5A (WSL211W)LED Linear 6 -LLP 6A source Results based on test LTL22004100°beam spread.Note:LM79 Tests-see page 4. P ower:The Winline 200 series operateson 24VAC using magnetic transformers. 2700 Kelvin -27K A wide range of remote transformers are available in 120V and 277V primary. 3000 Kelvin -30K 3500 Kelvin -35K color Dimming: Used with remote mounted 24VAC magnetic transformers wh ichcan4000 Kelvin -40K temperature be dimmed with commonly available low voltage magnetic dimming equipment. Mounting&Adjusting: Both fixed and adjustable mounts combined with an 24 volt -24 24 integral wire trayallows the 200 Series to be used almost anywh ere.The installer voltage locates and fastens the mount clip,runs power feed lines,connectsth e fixture's wire leads to thefeed lines and snaps thefixture in place.Thelow profile fixed Back to Back Feed(200ADJ)-200B2BA mount is only 1/8"high and the adjustable mount allows for 300 degree rotation Back to Back Feed(200FMC)-200B2BF around thecenterlineof thefixture.See pages 2-3 for more mounting and adjust- RightAngle Feed(200ADJ)-200RAA electrical ment information. RightAngle Feed(200FMC)-200RAF option Recessed Bottom Feed(200FMC)-200RBF Operating Temperature: Minimum and maximum ambient air temperatures SurfaceEnd Feed(200ADJ)-200SEA around thisluminaire shall not exceed-22°F to 104°F (-30°C to 40°C). Surface End Feed(200FMC)-200SEF Any application of this productsh ould also take into consideration air flow No Box Requiredor OrderedSeparately-NOBOX and ventilation to ensure performance and reliability. Refer to th a Winline ApplicationGuide (www.winonalighting.com/products/ natural(type Ill)anodized aluminum-NAA commercial-led-lighting/led_linear/207-209-211)for more productdetail. semi gloss black paint-SGB Weight: 12"-.57 lbs 36"-1.53 lbs semi gloss wh itepaint-SGW finish 18"-.79 lbs 42"-1.78 lbs custom paint finish-CP F 24"-1.04 lbs 48"-2.03 lbs 30"-1.29 lbs modified-MOD Warranty: 5-year limited warranty.Complete warranty terms located at DescribeModification: special www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a resultof end-user environment and application.All values are design or typical values,measured under laboratory conditionsat 25°C. IP66 COMP S Listing: Winline WSL207W/209W/211W is ETL listed forwet location. Complies with UL Standard 2108 W I N O N A Winona Lighting • 3760 West Fourth Street• Winona,MN 55987 • 800.328.5291 • www.winonal ighting.com Rev.05/12/15 WSL_207W_209W-211W solutions forms 1 light ©2013-2015 Acuity Brands Lighting,Inc.All Rights Reserved."Winona"is a registered trademark of Acuity Brands Lighting.Products herein may be SMcuityBrands. covered by one or more U.S.Patents and Patents Pending.Specifications subject to change without notice. 1 winonaLED winline surface linear 207W/209W/211Wwet mounting The Winline 200 Series is available in lengths up to 48"in 6"incrementsstartingat 12". Mounting The 200 Series can be mounted end-to-end with no shadows between units. Two unique mounting methods allow for flexible, quick and easy installation.The extruded aluminum body snaps into the mounting hardware and the included wiring cover encloses all wiring.Both mounts can be mounted in any position. The integ ral wire cover keeps wiring organized and hidden no matter what orientationthe fixture is in. Fixed Mount (200FMC) Nominal Installed Length Length MSL1 12.64" 321.00mm 1.87" MSL1/6 18.64" 473.40mm 47.62mm MSL2 24.64" 625.80mm MSL2/6 30.64" 778.20mm MSL3 36.64" 930.60mm MSL3/6 42.64" 1083.00mm _1.43" Luminaires can be mounted as Fixed Mount MSL4 48.64" 1235.40mm36.35mm close as.125"min.(3.18mm) �, f iii 0 ii ii 1.53" 1.64" ._.1138.78mm O 41.78 mm c c ar i 1_A C 7 _L ___ - _� L L---, -� I � 1 200RBF-Recessed Bottom Feed; -1 200FMC-Fixed Mount Clips 4 1 can be mounted � �I � � 200SEF-Surface End Feed (only one required) I Use standard switch box(by others) anywherealong luminaire F t F 7 I - ` I + -I (only one required) Adjustable Mount (200ADJ) Nominal Installed Length Length MSL1 13.517" 343.40mm 1.85" MSL1/6 19.517" 495.80mm 46.92mm MSL2 25.517" 645.20mm MSL2/6 31.517" 800.60mm MSL3 37.517" 953.00mm MSL3/6 43.517" 1105.40mm 1.68" MSL4 49.517" 1257.80mm Luminaires can be mounted as 42.55mm Adjustable Mount close as.125"min.(3.18mm) r, f F as �, j 2.11" 0 il 1.64" 53.59 mm 41.78mm0 I I I i " o screw holes located.5"(12.70mm) 200SEA-Surface End Feed from end of luminaire (only one required) The 200 Series Adjustable Mount allows for300 deg reecontinuous rotation. Luminaire can then be locked into place once desired position is established. linear plan Linear Plan Winona offersthe ability to providea c ontinuousrun plan to suit your requirements by optionally offering three methods of c onfiguration. LL SLinearSameLength: 4' 4' 4' 4' 4' In this c onfigurationeac hsegment is the same length is standardized based on the longest length available LSL 20 FT I I I I I i and is the only option provided.Bec auseit is dependent on one segment length thereare mathematic al limitations on what overall row lengths c an be ac hieved.Example:20 FT rowwould be ac hievedwith(5)4FT long segments equaling 20 FT(nominal). 3' 4' 4' 4' 4' 3' LCBLinear Center Balanc ed: LCB22FT I I I I I I I Thisc onfigurationincorporates the longest c entersegment(s)along with any additional lengths requiredto fill loc atedat eac hend.Example:22FT row would have(2)3FT segments(one at eac hend)and(4)4FT 2' 4' 4' 4' 4' 4' intermediate segments loc atedin between. LLP Linear Longest Possible: LLP22FT I I I I I I I In this plan the longest length available is optimized resulting in the fewest segments and mounting loc ations.Caution should be used wherebalanc edappearanc eis a c one ernExample:22FT rowwould have (5)4 FT segments and(1)2 FT segment loc atedat one end. W I N O N A Winona Lighting • 3760 West Fourth Street• Winona,MN 55987 • 800.328.5291 • www.winonal ighting.com Rev.05/12/15 WSL_207W_209W_211W solutions I forms I light C 2013-2015 Acuity Brands Lighting,Inc.All Rights Reserved."Winona"is a registered trademark of Acuity Brands Lighting.Products herein may be SMcuityBrands. covered by one or more U.S.Patents and Patents Pending.Specifications subject to change without notice. 2 winonaLED winline surface linear 207W/209W/211Wwet power,dimming, and wiring The WINLINE 200 Series is to be powered by 24VAConly. Do not connect directly to line voltage under any circumstance. Connection to line voltage will permanentlydamage internal components and void manufacturer's warranty. POWER REQUIREMENTS Power Maximum The WINLINE 200 series must be powered by a magnetic Model Consumption Run Length / transformer. Do not use electronictransformers.Multiply run WSL207W 3.2 w/ft 54 ft 24VAC length by power consumption to calculate transformer wattage. WSL209W 6.2 w/ft 38 ft Transformer Total run wattage should not exceed 80%of the transformer WSL211W 12.2 w/ft 28 ft wattage. Luminaires can be mounted as close as.125"min.(3.18mm) /o o/ I II II e>•ilir .SAP eillram� Dimming DIMMING (if required) The WINLINE 200 Series is easily dimmed with Magnetic Low Voltage(MLV)Dimmers.Not all MLVdimmers are by others alike,even among the same manufacturer. Confirmwith dimming equipment manufacturer that dimmer selected is designed to work with the transformer selected. 120V or 277V MOUNTING AND WIRING 200FM C FIXED MOUNT 1 2i% 3 I c-f '-31;e1-igi - :00,,,..- --_-.17:1 �N 6-1411 4.41 1.Locate end feed box,layout,and fasten 2. Trim luminaire feed wires as required but 6.Snap fixture into the fixed mounts to secure. the mount clips to mounting surface. DO NOT REMOVE FUSE! 3. Connect luminaire wires to powerfeed wires with supplied connectors(as shown in connector detail below). 4. Bundle wires and secure inside bottom of housing with supplied wire clips. 200ADJ ADJUSTABLE MOUNT 5. Snap wire tray into housing bottom. 12 as 3 1.Locate endfeed box,layout and mark 4. Trim luminaire feed wires as required but 8. Align boss on luminaire endcap into hole the mount locations. DO NOT REMOVE FUSE! on mount cap 2.Remove 2 screws holding mount caps 5. Connect luminaire wires to power feed wires 9. Install mount caps to mount bases. to mount bases and secure mounts to with supplied connectors(as shown in 10.Aim as required and lock in place with mounting surface with appropriate fasteners. connector detail below). set screw at top of mount cap. 3.Lay feed wires over mounts from 6. Bundle wires and secure inside bottom of connection box through end of run. housing with supplied wire clips. 7. Snap wire tray into housing bottom. REMOTE MOUNTING CONSIDERATIONS CONNECTOR DETAIL 3M EP300 ShrinkTube The WINLINE 200 Series is powered fromremote-mountedtransformers. The maximum remote distance of the transformer is dependent on many 10-12GA.Male Push-On Terminal factors including total LED load, wire size,distance fromthe transformer 14-16GA.Female 10-12GA.Wire to the first fixture in each run,and starting voltage at the transformer. Push-On Terminal (field wire) The installer is to ensure that 24VACis present at the beginning of the run. By using a combination of large-gauge wire and adjusting the output voltage of the transformer,the installer can compensate for voltage drop 1(fixt4-1ure8GA.wirWiree) 10-12GA.Piggy Back over long remote distances. Use of#12 wire is recommended. Push-On Terminal 10-12GA.Wire (field wire) W I N O N A Winona Lighting • 3760 West Fourth Street• Winona,MN 55987 • 800.328.5291 • www.winonal ighting.com Rev.05/12/15 WSL_207W_209W_211W solutions I forms I light C 2013-2015 Acuity Brands Lighting,Inc.All Rights Reserved."Winona"is a registered trademark of Acuity Brands Lighting.Products herein may be SMcuityBrands. covered by one or more U.S.Patents and Patents Pending.Specifications subject to change without notice. 3 winonaLED winline surface linear 207W/209W/211Wwet connection Fixed Mount M. **200RAF RIGHT x1.43' m Three styles of stainless steel conduit ANGLE FEED 1 connection hubs are available for connections 1111 at ends, middle, or corners of runs. \2.63" 0/.1.1111 66.68mm ,41 111 - 1; , *200B2BF-BACK 1.87" i 50mm 2 BACK FEED %l: 10 ***200SEF-SURFACE END FEE D *200B2BF-BACK 2 BACK FEE D 1.45" 2.3. 36.83mm 2.63" 1. CCH Base \/ 66.880mm� 2. CCH Cover = 3. Screws PPHMS I\� 66.67mm (ID 2.62" f'— i 8-32 X 3/16" LG. SS 1.64„ 41.65mm 0 1. ._L , r **200RAF-RIGHTANGLE FEED 1.43" 1..444 3, 2. 36.44m l 36.44mmi 1. CCH Base' ® f'- -r .f 2. CCH Cover 0 1.52" 0 1 3. Screws PPHMS ' 38.78mm 8-32 X 3/16" LG. SS 1 , ***200SEF-SURFACE END FEE D 1.43" 6.35mm _ 1.87" 1. CCH Base 2' /3 47.62mml 4.4 2. CCH Cover / ® i i—r i 3. Screws PPHMS 1.52„ 8-32 X 3/16" LG. SS '' 1 38.78mm 0 1, 1. �_/ W I N O N ' Winona Lighting • 3760 West Fourth Street• Winona,MN 55987 • 800.328.5291 • www.winonal ighting.com Rev.05/12/15 WSL_207W_209W_211W solutions I forms I light C 2013-2015 Acuity Brands Lighting,Inc.All Rights Reserved."Winona"is a registered trademark of Acuity Brands Lighting.Products herein may be SMcuityBrands. covered by one or more U.S.Patents and Patents Pending.Specifications subject to change without notice. 4 winonaLED winline surface linear 207W/209W/211Wwet connection Adjustable Mount **200RAA-RIGHT 1.52" Three styles of stainless steel conduit ANGLE FEED 3862mm connection hubs are available for connections '441W at ends, middle, or corners of runs. Jul 2.22" 56.3 6mm 14 II/ 4 , l 1.88" *200B2BA-BACK 47.64mm 2 BACK FEED 4� � �IP ***200SEA-SURFACE END FEED *200B2BA-BACK 2 BACK FEED 1.69" 3. 2. 42.95mm I 1. CCH Base / I I 2.62^ 2. CCH Cover r66.67mml 3. Screws PPHMS 66.67mm ® In 8-32X 3/16"LG.SS 1•67° 42.57mm 1. . I I **200RAA-RIGHT ANGLE FEED 1.67" FF 1.67" 3, 2. r42.64mm 42.64mml 1. CCH BaseI - ® 1•--- —F �i 2. CCH Cover . 1.67" 41.1.62"38mm 3. Screws PPHMS .58mm 42 8-32X 3/16"LG.SSI5 • 1. / ***200SEA-SURFACE END FEED 1.67" 42.55mm] 1 88" 3. 2. 1. CCH Base a7.7smm 2. CCH Cover I 1 i 3. Screws PPHMS �1 2'00 0 1.64" _ 52.79m 8-32X 3/16"LG.SS 41.78mm0 • 1. W I N O N ' Winona Lighting • 3760 West Fourth Street• Winona,MN 55987 • 800.328.5291 • www.winonal ighting.com Rev.05/12/15 WSL_207W_209W_211W solutions I forms I light ©2013-2015 Acuity Brands Lighting,Inc.All Rights Reserved."Winona"is a registered trademark of Acuity Brands Lighting.Products herein may be SMcuityBrands. covered by one or more U.S.Patents and Patents Pending.Specifications subject to change without notice. 5 winonaLED winline surface linear 211W wet photometrics 15° Test Report: LTL21998 Catalog Number:WSL211WMSL4 15DEG30K Candlepower Distribution 3000K Description: Nichia 757 3000K LE Ds/4F Winline WSL211W Wet Luminaire/E xtruded4luminum Housing/Acrylic Lens f,',' Horizontal Plane '.,Fill, ¢` 0 22.5 45 67.5 90 "� , LM79 Data-Based on WSL211W MSL4 15DEG 30K Test Rs ,-. o 2303 2303 2303 2303 2303 ,,, Total Lamp Lumens Power 5 2280 2307 2298 2256 2218 ,, `„lii�' ,, Color Multiplier Lumens Watts per Watt CRI Factor 10 2301 2292 2 02 9 1751 1636 - ` �'. 15 2344 2138 1451 1029 910 _� �. ANSI-binned 2 700K 0.97 1916 48.5 39.5 84.2 .87 _ 20 2415 1764 872 589 526 -��,k��- ANSI-binned3000K 1.00 2255 48.5 46.4 82.6 .87 25 2 52 5 1247 542 440 410 :.�.,`���- 2 ANSI-binned3500K 1.16 2345 48.5 48.3 83.0 .87 30 2622 817 407 303 274 ,���'�I"I` ,'' ANSI-binned 4000K 1.21 2479 48.5 51.1 87.0 .87 35 2160 5561 217 198 204 40 2160 412 2 17 198 2 02 4 fr ,, 45 162 0 32 3 184 198 2 02 ,I" �� 1 50 1133 2 54 170 188 183 iliMPAW► Zonal Lumen Zone-1 Lumens %Fixture 55 754 207 151 149 150 �411111.01ri Summary 60 479 164 118 118 125 3000K 0-30 1067 47.3 65 292 124 91 106 109 Maximum Candela=2623 LocatedAt Horizontal Angle=0,Vertical Angle=5 0-40 1451 64.3 70 169 92 71 84 79 #1-Vertical Plane ThroughHorizontal Angles(0-180)(ThroughMax.Cd.) 0-60 1979 87.7 75 90 62 53 54 48 #2-Vertical Plane ThroughHorizontal Angles(90-270) 0-90 2199 97.5 80 43 35 38 35 32 Total 85 13 18 27 24 22 Luminaire 0-180 2255 100.0 90 1 11 20 18 18 30° Report: LTL22002 Catalog Number:WSL211W MSL4 30DEG30K Candlepower Distribution 3000K Description: Nichia 757 3000K LE Ds/48"Winline WSL211W Wet Luminaire/E xtrudedJluminum Housing l Acrylic Lens d Horizontal Plane ",,1Wit,, a` 0 22.5 45 67.5 90 ,,"OW , LM79 Data-Based on WSL211W MSL4 30DEG 30K Test Results 0 1401 1401 1401 1401 1401 Total Lamp Lumens Power 5 1381 1437 1520 1591 1606 ,, 1111� �. ColorTemperature Multiplier Lumens Watts per Watt CRI Factor 10 1386 1541 1732 1801 1800 15 1397 1643 1723 1585 1460 -==, ==- ANSI-binned2700K 0.97 1916 48.4 38.9 84.3 .87 20 1425 1614 1432 944 784 �-_� ANSI-binned3000K 1.00 2255 48.4 45.7 82.6 .87 25 1463 1497 907 516 448 11111111111007101111, �i`a�r�.- ANSI-binned 3500K 1.16 2345 48.4 47.5 83.0 ,87 30 1440 1318 537 340 295 .,��1111,�=� 2 35 1360 1694 3665212 206 � ANSI-binned4000K 121 2479 48.4 50.7 87.0 .87 40 1168 694 258 212 206 ,�� , 1 45 1027 449 208 202 202 ,*RAO' ' ', 50 891 306 176 188 198 Zonal Lumen •-Zone Lumens %Fixture 55 753 218 149 162 159 Summary 60 604 161 124 131 140 3000K 0-30 1031 46.5 65 430 122 102 116 114 Maximum Candela=1801 LocatedAt Horizontal Angle=0,Vertical Angle= 0-40 1409 63.5 70 257 90 84 94 81 5#1-Vertical Plane Through Horizontal Angles(0-180) 0-60 1918 86.5 75 129 61 61 60 48 #2-Vertical Plane ThroughHorizontal Angles(90-270) 0-90 2170 97.8 80 57 37 43 37 32 Total 85 18 20 28 24 22 0-180 2219 100.0 Luminaire _ 90 1 9 16 16 16 60° Test Report: LTL22003 Catalog Number:WSL211W MSL4 60DE G30K Candlepower Distribution 3000K Description: Nichia 757 3000K LE Ds/48"Winline WSL211W Wet Luminaire/E xtruded4luminum Housing/Acrylic Lens °' Horizontal Plane $11111* .,1 ,, a` 0 22.5 45 67.5 90 OW •- LM79 Data-Based on WSL211W MSL4 60DEG 30K Test Results o 1252 12 52 1252 12 52 1252 , ,'�3�,, Total LampLumens Power 5 12291256 1278 1300 1298 ,, `„r73�� ,, ColorTemperature Multiplier Lumens WattperWatt CRI Factor 10 1218 12 ss 1354 1444 1459 .` `" '. 15 1199 1294 1429 1448 1446 -� . ANSI-binned 2700K 0.97 1835 48.5 37.8 84.2 .87 20 1171 1348 1412 1311 1184 -�k,���- ANSI-binned 3000K 1.00 2160 48.5 44.5 82.6 .87 25 1138 1312 1246 716 579 1111.101114111%07711113141741..._4111 ANSI-binned 3500K 1.16 2246 48.5 46.3 83.0 .87 30 1102 1285 715 380 330 i,iii0A. 2 ANSI-binned4000K 1.21 2374 48.5 48.9 87.0 .87 35 1066 1124 3926218 220 I,' `,,' 40 1027 827 269 218 226 � I"► _ 45 _942 477 207 200 185 \ - 1 50 857 300 167 162 178 .I 4��I'- Zonal Lumen Zone Lumens %Fixture 55 782 210 147 156 148 4012 la Summary 60 672 153 116 126 128 3000K 0-30 924 42.2 65 463 113 95 115 122 Maximum Candela=1459 LocatedAt Horizontal Angle=0,Vertical Angle=5 0-40 1341 61.3 70 256 90 82 91 92 #1-Vertical Plane ThroughHorizontal Angles(0-180)(ThroughMax.Cd.) 0-60 1884 86.1 75 122 61 62 59 52 #2-Vertical Plane ThroughHorizontal Angles(90-270) 0-90 2170 99.2 80 52 35 40 35 31 Total - 85 16 17 24 21 21 Luminaire All. 2188 100.0 90 1 7 11 12 13 100° Test Report: LTL22004 Catalog Number:WSL211W MSL4 100D EG3OK Candlepower Distribution 3000K Description: Nichia 757 3000K LE Ds/48"Winline WSL211W Wet Luminaire/Extruded4luminum Housing/Acrylic Lens o, Horizontal Plane '.,1-11,. ¢`_ 0 22.5 45 67.5 90 Mit , LM79 Data-Based on WSL211W MSL4 100DEG 30K Test Results 0 957 957 957 957 957 i ,,, Total Lamp Lumens Power 5 932 955 966 972 972 ,, ,';1y� ,. Color Multiplier Lumens Watts per Watt CRI Factor 10 920 948 968 980 983 .`` g., '- 15 897 932 961 968 967 _`, �. ANSI-binned 2700K 0.97 1929 48.6 39.6 84.2 .87 20 865 909 936 950 952 -==r=- ANSI-binned 3000K 1.00 2269 48.6 46.6 82.6 .87 25 823 876 904 911 905 10ANSI-binned3500K 1.16 2359 48.6 48.5 83.0 .87 30 773 834 859 846 830 2ANSI-binned4000K 1.21 2517 48.6 51.8 87.0 ,87 35 715 781 791 754 726 40 653 716 702 634 590 , ,,' 45 586 646 592 475 408 1 Zonal Lumen one Lumens %Fixture 50 511 561 ass 300 251 55 432 464 315 193 176 Summary 3000K 0-30 768 33.8 60 348 356 193 141 134 0-40 12 41 54.7 65 2 64 2 40 12 7 108 104 Maximum Candela=983 LocatedAtHor¢ontalAngle=0,Vertical Angle=5 70 183 140 88 90 84 #1-Vertical Plane ThroughHorizontal0-60 1953 86.1 Angles(0-180) 75 i11 80 65 59 56 #2-Vertical Plane ThroughHorizontal Angles(90-270) 0-90 2221 97.9 80 55 45 38 36 35 Lumina rel 0-180 2269 100.0 85 _19 21 21 22 22 90 1 8 12 14 14 W I N O N A Winona Lighting • 3760 West Fourth Street• Winona,MN 55987 • 800.328.5291 • www.winonal ighting.com Rev.05/12/15 WSL_207W_209W_211W solutions I forms I light C 2013-2015 Acuity Brands Lighting,Inc.All Rights Reserved."Winona"is a registered trademark of Acuity Brands Lighting.Products herein may be SMcuityBrands. covered by one or more U.S.Patents and Patents Pending.Specifications subject to change without notice. 6