Loading...
HomeMy WebLinkAboutB17-0193.002 Approved Plans01/09/18 NEW CONCRETE DRIVEWAY (HEATED) NEW CONCRETE DRIVEWAY (HEATED) PARKING 1 PARKING 2 PARKING 3 PARKING 4 EXISTING RESIDENCE PROPOSED ADDITION EXISTING DECK PROPOSED ADDITION PROPOSED DECK 2ND FLR 2ND FLR NEW GRAB RAIL EXISTING RIDGELINEEXISTINGRIDGELINE NEW RIDGELINEEL = 8412.628398.0' 15' SIDE YARD SETBACK 5' UTILITY EASMENT (RECEPTION NO. 97704) SNOW STORAGE 64 SF SNOW STORAGE 112 SF SNOW STORAGE 166 SF DRIVEWAY AREA - 2227 SF REQUIRED SNOW STORAGE (10%) - 223 SF PROVIDED SNOW STORAGE - 428 SF 20' FRONT YARD SETBACK15' REAR YARD SETBACKLIMITS OF DISTURBANCE LIMITS OF DISTURBANCE TEMPORARY EROSION CONTROL 1. PROVIDE EROSION CONTROL IN CONFORMANCE WITH BEST MANAGEMENT PRACTICES. 2. INSTALL A "GEOFAB" SILT FENCE AT THE LIMITS OF DISTURBANCE DOWNHILL OF CONSTRUCTION AND IN PATHS OF DRAINAGE PRIOR TO EXCAVATION AND MAINTAIN IN PLACE UNTIL FINISHED GRADE IS ACHIEVED. 3. INSTALL A "GEOFAB" SILT FENCE OR A STRAW BALE SATURATION BERM AT THE BASE OF TOP SOIL OR FILL SOIL STOCKPILES TO CONTROL SILT AND SEDIMENT. 4. G.C. SHALL BE RESPONSIBLE FOR PREVENTING THE RELEASE OF SEDIMENT LADEN WATER (MUD) FROM THE SITE AND SHALL BE REQUIRED TO INSTALL ADDITIONAL CONTROL FACILITIES AS NEEDED FOR THE PROJECT. SEPARATEHEATING IN ZONE IN R.O.W SNOW STORAGE 86 SF DECORATIVE LANDSCAPE BOULDERS SHEET OF : I S S U E S L A N D S C A P E A R C H I T E C T N O T E S DATEDESCRIPTION NO. A Vail DRB Submittal 09.26.16 16-227 PROJECT NO.: September 21, 2017 DATE: ral DRAWN BY: SCALE: RAL Architects, Inc. 2017 C Edwards, Colorado 81632 email ~ bobbyl@ralarch.comP.O. Box 1805 Phone ~ 970.376.4227Meuer Residence Vail, CO 81657 S T R U C T U R A L - Shapiro Chalet Tract A 3876 Lupine Drive Addition B Building Permit 05.07.17 C Permit Revisions 06.27.17 D Permit Revisions 07.13.17 E Permit Revisions 07.18.17 F Driveway Revisions 09.21.17 Site Plan A0.1 GRFA Calcuation Lot Size - .458 acres, 19971sf Allowable GRFA - 7146sf Lower Floor GRFA - Existing 1219sf - Proposed 1806sf Main Floor GRFA - Existing 1519sf - Proposed 1545sf Upper Floor GRFA - Existing 1040sf Total Proposed GRFA - 4391sf 01/09/18 01/09/18 GARAGE GUEST BEDROOM BATHCLOSET MECHANICAL LIVING ROOM BATH DECK TOTAL AREA - 1519 SF GARAGE DEDUCTION - 300 SF GRFA - 1219 SF TREE TOTAL AREA - 2106 SF LIVING ROOM BATH GARAGE GUEST BEDROOM BATHCLOSET MECHANICAL MUD ROOM GARAGE DEDUCTION - 300 SF GRFA - 1806 SF DECK TREE 35 '-2" 17 '-7" 17'-7" 2 3 ' - 41 4" 2 ' -51 2" 1 0 '-5 1 4" 1 0 ' - 5 1 2" 7'-5 3 4"7 ' - 81 8"1'-112"6'-21 2" 01 101 102 DOOR SCHEDULE DOOR SIZE 3'0" x 6'8" GARAGE ROOM GARAGE # 101 102 STYLE TYPE COMMENTS HINGED HALF GLASS O'HEAD WOOD HARDWARE TYPE N/A ENTRY 20 MIN RATED, CLOSER 103 MUDROOM103 HINGED TYP INT ENTRY 16'0" x 7'0" 3'0" x 6'8" MINIMUM R-VALUE - 6.5 U VALUE = 0.27 OR BETTER 192 SF 02 NEW BOILER 1 - 100,000 BTU NEW BOILER 2 - 75,000 BTU EXISTING HOT WATER HEATER EXISTING FLOOR DRAIN NEW MFGR PROPRIETARY 4" DIA VENT, 4" DIA AIR INTAKE MAINTAIN MFGR REQUIRED SEPARATIONFROM ADJACENT WINDOW VENT/AIR INTAKE 104 MUDROOM104 HINGED TYP INT ENTRY2'8" x 6'8" 4'-7"31 2 " 3'-6" 3 12 "01 3'-0" 3'-0"4'-0"7'-0"U=0.32 OR BETTER 02 3'-6"6'-0"6'-8"EGRESS TYPICAL GLAZING AREA - 16.41 SF WINDOW SCHEDULE SAFETY GLAZING REQUIRED T T EXISTING 1" GAS SHUT OFF SHUT OFF SHUT OFF NEW BOILER 1 NEW BOILER 2 TO HOUSE CEILING NEW 1" GAS SHEET OF : I S S U E S L A N D S C A P E A R C H I T E C T N O T E S DATEDESCRIPTION NO. A Vail DRB Submittal 09.26.16 16-227 PROJECT NO.: December 11, 2017 DATE: ral DRAWN BY: SCALE: RAL Architects, Inc. 2017 C Edwards, Colorado 81632 email ~ bobbyl@ralarch.comP.O. Box 1805 Phone ~ 970.376.4227Meuer Residence Vail, CO 81657 S T R U C T U R A L - Shapiro Chalet Tract A 3876 Lupine Drive Addition B Building Permit 05.07.17 C Permit Revisions 06.27.17 D Permit Revisions 07.13.17 E Permit Revisions 07.18.17 F Driveway Revisions 09.21.17 G TOV Revisions 10.20.17 H Owner Revisions 12.11.17 Lower Floor Plan A1.1 Existing Ground Floor Plan Scale: 1/4" = 1'-0" Proposed Ground Floor Plan Scale: 1/4" = 1'-0" Mechanical Room Gas Riser Diagram Scale: 1/4" = 1'-0" 01/09/18 01/09/18 01/09/18 01/09/18 01/09/18 All 15A and 20A circuits to be GFCI protected in accordance with article 210.8 of the 2014 NEC 01/09/18 01/09/18 01/09/18 01/09/18                           ߰ !"! #$ %&'() *"+ &##$߰&(#, !$-&. +**(($  ./ 0 &/ 1 2 1 ' 1  3 (!$ 4 +  ' * '04 5 + ! ߰   6 #0 1  789: (. !(2. %!;<8==+&4;>> 789: (. !(2. %!;<87?> 7@ .,+&߰ <<? 7@ .,&+߰ >=> 7@ .,+&߰ >=7       &/ A / B*: & C / B*:&A / B*:$ ' 1    01/09/18 07/13/2017 01/09/18 07/03/2017 01/09/18 07/03/2017 01/09/18 07/03/2017 01/09/18 P:\1900-1999\1957\ACAD16\1957-2-TACAD16.dwg, Layout1, 6/6/2016 3:44:50 PM01/09/18