HomeMy WebLinkAboutB17-0193.002 Approved Plans01/09/18
NEW CONCRETE DRIVEWAY
(HEATED)
NEW CONCRETE DRIVEWAY
(HEATED)
PARKING 1
PARKING 2
PARKING 3 PARKING 4
EXISTING RESIDENCE
PROPOSED ADDITION
EXISTING DECK
PROPOSED
ADDITION
PROPOSED
DECK
2ND FLR
2ND FLR
NEW GRAB RAIL
EXISTING RIDGELINEEXISTINGRIDGELINE NEW RIDGELINEEL = 8412.628398.0'
15' SIDE YARD SETBACK
5' UTILITY EASMENT (RECEPTION NO. 97704)
SNOW STORAGE
64 SF
SNOW STORAGE
112 SF
SNOW STORAGE
166 SF
DRIVEWAY AREA - 2227 SF
REQUIRED SNOW STORAGE (10%) - 223 SF
PROVIDED SNOW STORAGE - 428 SF
20' FRONT YARD SETBACK15' REAR YARD SETBACKLIMITS OF DISTURBANCE
LIMITS OF DISTURBANCE
TEMPORARY EROSION CONTROL
1. PROVIDE EROSION CONTROL IN CONFORMANCE WITH BEST
MANAGEMENT PRACTICES.
2. INSTALL A "GEOFAB" SILT FENCE AT THE LIMITS OF DISTURBANCE
DOWNHILL OF CONSTRUCTION AND IN PATHS OF DRAINAGE PRIOR TO
EXCAVATION AND MAINTAIN IN PLACE UNTIL FINISHED GRADE IS
ACHIEVED.
3. INSTALL A "GEOFAB" SILT FENCE OR A STRAW BALE SATURATION BERM AT
THE BASE OF TOP SOIL OR FILL SOIL STOCKPILES TO CONTROL SILT AND
SEDIMENT.
4. G.C. SHALL BE RESPONSIBLE FOR PREVENTING THE RELEASE OF SEDIMENT
LADEN WATER (MUD) FROM THE SITE AND SHALL BE REQUIRED TO INSTALL
ADDITIONAL CONTROL FACILITIES AS NEEDED FOR THE PROJECT.
SEPARATEHEATING IN
ZONE IN R.O.W
SNOW STORAGE
86 SF
DECORATIVE LANDSCAPE BOULDERS
SHEET OF :
I S S U E S
L A N D S C A P E
A R C H I T E C T
N O T E S
DATEDESCRIPTION NO.
A Vail DRB Submittal 09.26.16
16-227
PROJECT NO.:
September 21, 2017
DATE:
ral
DRAWN BY:
SCALE:
RAL Architects, Inc. 2017 C Edwards, Colorado 81632 email ~ bobbyl@ralarch.comP.O. Box 1805 Phone ~ 970.376.4227Meuer Residence
Vail, CO 81657
S T R U C T U R A L
-
Shapiro Chalet Tract A
3876 Lupine Drive
Addition
B Building Permit 05.07.17
C Permit Revisions 06.27.17
D Permit Revisions 07.13.17
E Permit Revisions 07.18.17
F Driveway Revisions 09.21.17
Site
Plan
A0.1
GRFA Calcuation
Lot Size - .458 acres, 19971sf
Allowable GRFA - 7146sf
Lower Floor GRFA - Existing 1219sf - Proposed 1806sf
Main Floor GRFA - Existing 1519sf - Proposed 1545sf
Upper Floor GRFA - Existing 1040sf
Total Proposed GRFA - 4391sf
01/09/18
01/09/18
GARAGE
GUEST BEDROOM
BATHCLOSET
MECHANICAL
LIVING ROOM
BATH
DECK
TOTAL AREA - 1519 SF
GARAGE DEDUCTION - 300 SF
GRFA - 1219 SF
TREE
TOTAL AREA - 2106 SF
LIVING ROOM
BATH
GARAGE
GUEST BEDROOM
BATHCLOSET
MECHANICAL
MUD ROOM
GARAGE DEDUCTION - 300 SF
GRFA - 1806 SF
DECK
TREE
35 '-2"
17 '-7" 17'-7"
2
3
'
-
41
4"
2
'
-51
2" 1
0
'-5
1
4"
1
0
'
-
5
1
2"
7'-5 3 4"7
'
-
81
8"1'-112"6'-21
2"
01
101
102
DOOR SCHEDULE
DOOR SIZE
3'0" x 6'8"
GARAGE
ROOM
GARAGE
#
101
102
STYLE TYPE COMMENTS
HINGED HALF GLASS
O'HEAD WOOD
HARDWARE TYPE
N/A
ENTRY
20 MIN RATED, CLOSER
103
MUDROOM103 HINGED TYP INT ENTRY
16'0" x 7'0"
3'0" x 6'8"
MINIMUM R-VALUE - 6.5
U VALUE = 0.27 OR BETTER
192 SF
02
NEW BOILER 1 - 100,000 BTU
NEW BOILER 2 - 75,000 BTU
EXISTING HOT WATER HEATER
EXISTING FLOOR DRAIN
NEW MFGR PROPRIETARY
4" DIA VENT, 4" DIA AIR INTAKE
MAINTAIN MFGR REQUIRED SEPARATIONFROM ADJACENT WINDOW
VENT/AIR INTAKE
104
MUDROOM104 HINGED TYP INT ENTRY2'8" x 6'8"
4'-7"31
2 "
3'-6"
3 12 "01
3'-0" 3'-0"4'-0"7'-0"U=0.32 OR BETTER
02
3'-6"6'-0"6'-8"EGRESS
TYPICAL
GLAZING AREA - 16.41 SF
WINDOW SCHEDULE
SAFETY GLAZING REQUIRED T
T
EXISTING 1" GAS
SHUT OFF
SHUT OFF
SHUT OFF
NEW BOILER 1
NEW BOILER 2
TO HOUSE
CEILING
NEW 1" GAS
SHEET OF :
I S S U E S
L A N D S C A P E
A R C H I T E C T
N O T E S
DATEDESCRIPTION NO.
A Vail DRB Submittal 09.26.16
16-227
PROJECT NO.:
December 11, 2017
DATE:
ral
DRAWN BY:
SCALE:
RAL Architects, Inc. 2017 C Edwards, Colorado 81632 email ~ bobbyl@ralarch.comP.O. Box 1805 Phone ~ 970.376.4227Meuer Residence
Vail, CO 81657
S T R U C T U R A L
-
Shapiro Chalet Tract A
3876 Lupine Drive
Addition
B Building Permit 05.07.17
C Permit Revisions 06.27.17
D Permit Revisions 07.13.17
E Permit Revisions 07.18.17
F Driveway Revisions 09.21.17
G TOV Revisions 10.20.17
H Owner Revisions 12.11.17
Lower
Floor
Plan
A1.1
Existing Ground Floor Plan
Scale: 1/4" = 1'-0"
Proposed Ground Floor Plan
Scale: 1/4" = 1'-0"
Mechanical Room Gas Riser Diagram
Scale: 1/4" = 1'-0"
01/09/18
01/09/18
01/09/18
01/09/18
01/09/18
All 15A and 20A circuits to be GFCI
protected in accordance with article
210.8 of the 2014 NEC
01/09/18
01/09/18
01/09/18
01/09/18
߰
!"! #$ %&'()
*"+ &##$߰&(#,
!$-&. +**(($
./ 0
&/ 1
2 1
' 1
3 (!$ 4
+
' *
'04 5 +
!
߰
6
#0 1
789: (.
!(2.
%!;<8==+&4;>>
789: (. !(2.
%!;<87?>
7@ .,+&߰ <<?
7@ .,&+߰ >=>
7@ .,+&߰ >=7
&/ A / B*: & C / B*:&A / B*:$ '
1
01/09/18
07/13/2017
01/09/18
07/03/2017
01/09/18
07/03/2017
01/09/18
07/03/2017
01/09/18
P:\1900-1999\1957\ACAD16\1957-2-TACAD16.dwg, Layout1, 6/6/2016 3:44:50 PM01/09/18