HomeMy WebLinkAboutLoad Calc 10-18-17.pdf ,siti OF to
..,"44,..
t.i•la
4
CR
10/25/17
TESLA
ELECTRIC
Load Calculation
Single Family Service Calculation
Adddress:Potato Patch Club(16-950 Red Sandstone Rd Code Refrence
Date:10/18/17
General Lighting Load 2,900 Sq.Ft. 3 VA 8,7(10.00 Total
Small Appliance 2 QTY 1,500 VA 3,000.00 Total Table 22012,Table 220.42,
laundry Circuit 2 1,500 VA 1,500.00 Total 220.524(1),220.52(8)
13,200.00 Sub-Total
3,000.00 3000 VA at 100%
3,570.00 9,000 VA-3,000 VA at 35%
5,570.00 Net Load
Range Demanded Load 1 QTY 8,000 VA 12 KW use 8KW,1greater Demand Factor 8,000.00 Total Table 22055
than 12 KW add 5%for
each Kw
Dryer Demanded Load 1 QTY 5,000 VA 5,00 or name plate rating Demand factor 5,000.00 Total 220.54,Table 220.54
which ever is grater
Fixed Appliance Demanded
Dishwasher 1 QTY 1,200 VA 1,200.00 220.53
Trash Compactor QTY 000 VA 600
lee Machine QTY 1,200 vA 000
Fridge 2 QTY 1,000 VA 2,000.00
Freezer QTY 1,000 VA 0.00
Wine Fridge QTY 800 VA 0.00
Sauna QTY 11,000 VA 0.00
Juccuzzi Tub QTY 2,500 VA 0.00
Suana QTY 3,800 VA 0.00
Steamer QTY 5,000 VA 0.00
Into Hot QTY 1,200 VA 0.00
Attic Fan QTY VA 0.00
Micorwave 1 QTY 1.500 VA 1,500.00
Water Heater QTY 4,800 VA 0.00
Disposal 1 QTY 1,500 VA 1,500.00
Frailer QTY 1,500 VA 0.00
Heat Tape 1 QTY 6,000 VA 6,000.00
Other:
12,200.00
0.75
Demand Factor4 or more appliances
9,150.00 Total
Heating and A/C Load QTY 11,300 VA 0.00 Total 220.51,220.50,220.60
100%of Largest Load ONLY
25%of Largest Motor 1 QTY 375 VA Motor Load Only-100%is 37550 Total
already included at 220.50,430.24,Annex D
Calculation Example 01(b)
29,095.00 Total Calculation Load
240 single Phase
12123 Amps
TeslaVail@gmail . com 970 . 331 . 5369