Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Public Safety Plan - July Phase II Occupants.pdf
A G E R O A D F R 0 � H `] EDGE ASPHALT S - 0 8142.4 £311:3.- 5 8140,6 q1"-.P.q ---- � •' ,.1= _:: _ CENTERLIN 8147.1 ! =: .9?: - DITCH 8149.0 �- "is _'I I. 11. ._ - - _ _ ` _ 8150.4 _- UTILITY PED - ...._. . 1 7 �- T [- 8135.7 ® ,. --� _TT_-" w- _ ... 1 ) _. .,. ii . /-- .,„,„„ . ....,___ __ _ ____ ___ __ ______ _._ _____ _ ______ ______ . ,. [ . / 7-- ___ _ .,7" -"-.-- . / / _ ___-____ __ _____ _. __. __, ---\ ._- ---- _ zis .__,.„4„ ,,_..„....A_ ........„," , _),- _,, ,,,A...„,„ . .. ._ 1, itiltn-.6 / ��� �� �� ENTERLINE 1 ;' �: -.-_ �__ _-_ _ _ ______ _____ _ _____ ___ _ - -- _ _ ___ ____ _ _ .___ _____ At, ().4 .00 Air / / / /� //d � 1 / ��*01; / // / r // d r �, 1 �� �� r REPLACE LYVN I °r .;. MANHOLE �,5 �(F� � �_ dialer� 1✓ / } _ _- X31'1 :rte _ - _ _ P i;;. I �►, •/� . / / _�-��r �;re .7P--.7?-r_. - �. T ■�=■;=:■! �,� �. T • 1 / 3 �TI« EASEMENT e -0,8 3 '.11 _ t.a / / / 3. _�. h. �. .: .� .�� e_�1 _ _ _ : ., •�- ' "s- = �7RSJES PED MA^H❑LE I.7 11011# .s / / v F F ti �p II f f f j. PHONE S ! I--I. I�.. k .-rl .�� � Ik ��.'. �I I k e � � -� k k -e _� � -�� f-III +� / / / NI1, •.. �� Hyl =1 _ �� - . _ ��_. _ �� ._. �� / C l' fl.2 / / / t. -1- t. �r1 �� 8132,0 / // / ,.. �_.■:. s �.■ =:.■ - '.- - ■.;sr.:: =.■: •-- �. r ..a.. �I T l c 1 • ii 5 ': . / s. � • x >i9. ?.i1 - �` -- ! FIRE 7 � ■ / / / r., I :TSF;I, I1 ,.:�'!.I I ,,;f~-1: :12' I ' ; I: :�' 'll ;I ' 1' `-; s . ; -. ...-,1-1,t. '`` / / J• • • i' t .• - i � :T . :i • - \ HYDRANT 0; ► / f I / yl , ` 1 -• 813 9:2 ! _l15 �� ... �� ------_, �. 47' .. PI I / f / I r�...�+=I.. �=i r .. -r� R - ', f � --,-- rte} Okr //- �� r / f // - / p; t31r1Ui7 / /// / 'fi .G.'-' • !.i, / - --- -- 44 13c.).7 1 X ■• 81446 / . tiefr Airr Ai. * ' 813 5._ 'GARAGE SLAB / =! M // // f f // fi..J/ . ,► �� J / 8144.5 ` N1 W 8' 1-fIGH GONGF2 STAIR +� �. / / / / / / / ':..`.'S 1GARAGE I + I �'RI V C Y /'&AL.L TO \' \ \ \ I sr II. // / / / , „ �. I SLAB ,+AIP � � .,►: 9,5 x // f// / / f/ /f . g „.. i��► ' ,`, , 8134.7 j ; MATCH fzGf-f )\ `. /`� , / / / •% / 7044 ' �' , f / 8158.3 X\ \ + ,, ..., / / / / , �',„' /, / / /„,,,„„, ._ / / / // / / A / / ., �y�, . , 1\ i / / / � 1 ; I 1 I \ I 1 11 // // IA:40 / / / L / / / • / �,vi,, - P�42fCING G�RG� �57� 5x ' / //7111/77,1°1111:;-e;// f / / / / "TN , l/, + r� r // r/ // . r // i 1 �ELaw GR�4DE J LION VAIL , / / / / / / 8145.8 , III � / /� / / • / I I ; j) ,C'C, ') - / / /V ■ / ENTRYI ■ir / // % / �/ / f /f / / 8145.2 �. 1 • '� i 1 li:- .' ir ,ilk,• / / / / �/ / / / // / I " 011* � 81 45.8 " �'_'`� I / d2 / / 74, • . / i 7,.7 ; / /- // / )6 .1/./ / • �r.► f . / / / - / ((o / / / - - 9.; I Is . // 7 / ... ..,./ / / Z x135 I �/ / . �,- . �° ENTRY r +' . I / / / / / / / / / � , 1 / / / / / / / / • • 8135.8 � � 1 f ? 1 / , / / / / / 4-4111 :134.0 II + { I/// / 11 /�/ /-////' Aar _�i .__fir`■__■� .__.izRop-Rim' I r �•fLJLir( fl y / • A ® 1 fig/ / * ]� ,r / _ -1:1�. ...�.�_g'•-��-_■, • ✓_.:: ♦� t j J r _ / / / :y��a ar' IiNTRY �!ec: ' lir- -- �;. �. \ i 2. . • 8136.8 -P;'14:"_•''�_' ^lb, . \ (} ff :. A r / f % f , • ri,. 4!...ito.v..;, t3 �'� ,>,^+bpi,y 1 8157.5 v14,44.4.4:0„,:„.,, t.„.tow ..s,.,....•'‘,•••44' 8125,1 / • 0 . -VMPItt I;.,,_ lir . ._ _11 ti.x,, 's` ........ „,/ '�: � i, it �1► 8I58-3 t FIRE /8t. .2/ / 9 r .•�,r - �� f313 .0 - I- \z� '� ' par k �• • -�� HYI]R�iNT / / • 11„// • / / •• •• s �� �. K155.0 1 v. � x 8134.4 _• -- !'. .� -. .. ........3,..4.8.1'..,1',1 :u,� �� . 8 f 55. :� / h• . , ,t,t 4if ;,r rsEA . • 1111 f OPTIONAL 0a % 1.4440...41V. '. ` + - 1111 8124,3 • `ti1f �' -• 1►i� :i r :132.9 !�L>'r� "�"` -__ . * '-'16;14:;144),.-/ifPOOL aFT1 aN�►L 1 �.� 5 L. •. . ,�/ is k / #4) '�,. ENTRY EN21AN at Vail / '� =1` SIM' / o' •`�'';�"� ',4T1D 8145.0, . . � / '�A� •: .;��;� .' ' ' , . . �;�s ': :� I Condominiums 8125.9 x - /f / / / 9 . . ^" . � 8132:• ♦* + . . / / / ru �� rte, 8,1-36 Ch. •_, ev .6 474 • i'� 1 0.4'- _./ �._. ".-r •y, Y1^4' .'- , 7aC. ' \ 34.9 �.. `���°? \` , . / �51�� l ,Mwv- 3 n .. -, - I x , 1 , ... . . . . . • \ // /8 i1 , r- .1� IF �Y ,�� \� <:; 8143.4 Jv #0 -1:LN ii �. 1. .::.:::.,,, 1 - ✓ i, ►jn �! . ♦ y ` is r/1:.;:,:#:;e:'4040'• _. ,.- :-c:. -It /7: /.. c s '1:11.!!$: . / . - 'N - - /_.,, • ...:: tib`.�� . . . . . . _. . . . , • ;: • MSR\ ...:44116.: ''''',, `.5 .� i \ i :. ::‘tor 7• =it _ cr••w`..,-�+ - 0 .-"-A"---------:-T ,, �'`�.' • iii;-' �+r_ e� N zZ __ ♦ �� % 'R: Q , -,I ___. • ��. . .. --.. -,.... -: _ :44 O c�. _. �•; 814,6 d N �. ''cF -` ` `..._ 1 _ ti13•l.] '?A. • ]- '' _� �.. .. ��, • •7e�RSr. �J-• y�. 111111 `l ` ti. • '''�� 6•':�-.E - � ,�. �> '�''', t' -, ra ; ` ! 3138.b ''4,,k,,,,,,,,,/,_,,. :ti 1� :4*.*:,*:/s/.:, o j -,"::v-. 7- ' .... 7p �= ,x �. s2 �� .r._ate ris:�..' �� a', • • +�: s rs # IP 38 } 7 1t \ 41111 11111111111111I • i0 3e '.. z, :r :: .. •• € 5" fes, '�' ��lt s �_ 1 •� • • i ,,,............„.._________, SI. N.1 •� In ''''-?-r..-',r' ._ �� .12z7,___ ,T,... . ... .... ... ...........„_ • `__ �s n ��• ' � r. `, 135.6 R 1. _4 1 X w r E313 '77 Y 8133.5 L 1 8131}.4 �� • � .. = . T ; ; ,: • >�, • • _ ..- NE1�I ��\ .. �. GF2C755KALK • Iltrt, ---- it, STRII�'1NG -__ r--..1111111 REr�aVENil - .� V " 4� .. art• - - ■ CONCRETE R I25J 8126-6 JAIALKS $ 8134.3 __ STEWS Ay 1 �r� ; C � � $� - NORTH D • �1 S1QRM 8134.0, / r Ill, W E S T C * 0 i , L I O N S H E A �1zAAT>~ A E I„ 3 / t Zf r 0i / III `'1 �JJ MARRIOTT o to' 20' 40` 1 / "' SG,�LF: l"=201-0" (on a 30 x 42" sheet) 1 I Page 10 of 23 ee121 /1/4...I. KY . . S e._ii ie. . 410...-. /b.' IQ I Si6 D AP,C Q, E A209 A202 7______ • cb OO C' 6 O 174'-10. 2 *� ,..., a_ c"+,i W. / C D A ...., . '=' r"-% -- r - ''..i) —1\ Zsi - r..... I d, 1 1 ' ) 'CU =., 0 — \ — ,_ 26'-8" r 5'-0" 12'-0" 16'-0" 25'-6" 25'-6" 19'-7" 12' 8 3/4" 14' 10 1/4" 5'-0" 12'-0" io L I- / / / / / / / / / / to\ -. 0 V 0 1 1 1 - 1....N / As ADA COMPLIANT LOCKER ROOMS,SHOWERS,AND `��� mmei \`/. TOILETS,SEE ENLARGED PLANS A404 AND A405 / � j N O No. Description Date 0 — — — — — — UNIT — O o III a am:o���■ a ^"iBE, 1 PROGRESS/PRICIN 2 OCT 115 � I! �„ i T G 15 ►. I m * MI 42 DRB REVIEW 12 OCT ofp� e m m e m a 1-1 _ a m 9 0 a I/ 15 -- O / IF. Y 0 a 0 0 (. m) e ,,) 0 /•• JI C121 / 3 PROGRESS/PRICIN 23 DEC O4s — \ — — — — -__BEE: — 97 E G 2 15 4,0 CDs/PERMIT 21 JAN O A, / O ;� 4� ® ® / O V =E- A201 2 " a — =:Z /UNIT / / O O NEW 90DEG HOLD / I UP U / 101 / OPEN DOORS FOR I / -/ �D / / / STAIRWELL TO LOBBY /7 O / �" ��Ao 14/ O jilS° / / ■' �' ,, NEW ADA PliOL LIF V-1 A210 5 �- / EXISTING GRAS.,/,` / _t/1/- / 4 / / UP r ■ AREA; NEW ENTRY ROOF AND �� _= EXISTING ' / VESTIBULE ——=s __ 1=1 FIREPIT ® T �i ,'"% L� ��� -- NEW ACCESSIBLE POOL EN Y -'-:',/,'-' ��t� I -- GATE AND PATH yC NT O — \ — — — • / } _ , . � — 1� ol / Q /.. / //°v ENTORANCE/ \\\ `? O Ire % / 8 ELEVATION ( / p, j V �' ============================== =°== IT UNIT / O --- 2 2 2 2 ------- ,,- -, - , ,1 N_ NEW ADA ACCESS RAMP N _ U�- A401 ============================ 105 103LL // _; � / / =___ - =_=___________________________ / / 1 UNIT 4 O \ ==== _ — ,, �, :'< / 102 I I = �� ' / PLANTING �R � / / / GENERAL PLAN NOTES - / 1 k, _, ,•'; _'.-` ,, ., ,_•r,, i0V, -. \ 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. =� NIT ` ! �'0 O 2. FURNITURE IS NIC U.N.O. N A210 �Q °/ [ / 107LL O �,4' Kd ® 3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER / �, - / 6 ' ,' ,` .,;• y,,:', lAilitiIiiiitiliNEE-„\_ / NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT / ' I __ O _ � BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D "L___birli /../ U) / — / \ f,, _________________O____________- / BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES w O ►�/ _ AND GARAGE AND OTHER UNCONDITIONED AREAS. 2 J _ _ / / _`'.' / NEW ADA ______ =_-il -. / EXISTINGCONC ETE POOLDCKAND POOL LIFT _ O \ / / 4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13. = STAIRS TO BE EEMOVED. PAVERS ON I I -======================___ I 11 V /1 SAND62DWITHS wMELTTo O 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE < D ��/ _:.:. REP CE OLD DECK „================================4______________ L.L / / / `. ', - ',a _____________ / DEPT 2 EXISTING BOXES ARE AT FDC LOCATIONS °' NIT % 1 ----------_ ' EN __________=___ • IT A201 `I�' , „ / =___________'-+ [� 1 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL U Al REPAIR POOL ANDHIOTTUBASNEEDED :.; ? A21011k `„;' ''r; 7EEEEEEEEEEEE `�0,, / / BE COORDINATED WITH STRUCTURAL. il Z 0 109LL / IN BASIN;NEW POOL COPING __- 7:_4 �=te ====________�� � rHRouGHour. ,y � d' \ � 127. PENETRATIONS ATROOF TOPUNITS & MAKE-UP AIR UNITS___ as aaamE ® ,` , ,. �F.yC OSHALLBECOORDINATEDWITHMECHANICALCONTRACTORFORQ== ==___ — / ` t _ 13SIZE AND LOCATION. UM) w�/ =_== == _ �' / O8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT2 i PERPENDICULAR WALL SHALL BE 4” U.N.O. 7 __ - ___ '"_ a,',_ , ,., .(' • , ,., ,V ,, \ UNIT UNIT DRYWALL PART'N BTWN NDITI NED PIED PA E- ._ � „/ / � 9 S CO O OCCU S C S& Z ___ "' / NIT / j. ', . °, GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. O\ ti / / a 4. ;. ' / / / 1 1 104 106BARRIER ON EXT. WHERESIDING SHOWN). O \� 113LL O Asoo _ JN / � ' : . \ 10. ALLPART'NS INOR ADJACENT TO PARKING GARAGE TO BE Q I , /�� l ,�_ '.j / \ __ CONSTRUCTEDONA51/2"x6"CONCCURB, RE: X/A5.04./ / 1 / 1 �// W(j�DSLATINGATALLG DE SITE WALLS WITH _ __ 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACEDZ >//�. / METAL CAP FLASHING. AREAS OF WALLSBELOW ri'L ` '� ________- ____________zi /TOBTALLERWITHBLOCK AND GLASS,WHER V �� _ IN-KIND W/REGARDTORATINGS, HARDWARE, ANDFINISHES, OR, o ` A , NEW SOD• ,D PLANTING AREA REQUIRED \ \ -=C ____\ - _________________ KEPT AS-IS. DETERMINED CASE BY CASE -SEE LOCATIONS ON Osc9 —��' / , NEWP OLSITEWALLS W/WOOD LATS AND 1 -�I O"Y '� -�1 \ `-S'i,�jL� -CO \ PLANS � / META�CAPFLASHING(METAL FEN E AREAS,TBD.) =_�A C__. __ MEMs C O ir, = =-= - A.," KY ' . S ,-,1i . ` go, D ;LAC STAIR TOWERS CLAD IN CORRUGATED CORTEN i WESTERN RIB STEEL `�' PANELS / \ °u. '-'-' REPLACE TRAFFIC COATING ON EXTERIOR A308 A202 NA202 ` '+� v _ E LANDINGS; REPAIR/REPAINT RAILINGS; COVER D E G = g • • GLULAM WITH COPPER AND COUNTER FLASH 0 O . Q O O 0 +.. U> co UNDER TRAFFIC COATING 2 1 2 E " STAIR TOWERS CLAD IN _ 10 A% — CORRUGATED CORTEN a I PRIVATE PATIO NEW PAVER �' , WESTERN RIB STEEL ,...... � REPLACEMENT(REMOVE PANELS � 0 EXISTING WOOD DECK) CD PRECAST CONCRETE WALLS A305 �'— II \ \ CLAD WITH HORIZONTAL 8" . itil - oii'li CEDAR SLAT SIDING lall 0 3 — — PLANTING kkk_°''°i is — \ / tr AREA =_____=-ess9 222* UNIT \ / ALL CAST-IN-PLACE CONCRETE TO / BE PATCHED AND REPAIRED WITH 2 / 201 EXISTING OFFICES AND MAINTANANCE AREAS / PROCESS EPDXY AND 3 COAT OFFICES AND HOUSEKEEPING / 1 1 1 STUCCO MIT ==========, - - POURED IN PLACE � 4 � No. Description Date — 307LL \„,„,,`,,,,,,_`,,1 STOEPS NCRETE PATIO A210 \ \\ \\, CD 50'-5 5/8° 1 PROGRESS/PRICIN 2 OCT )( G 15 NEW ENTRY DOORS CLEAN AND REPAIR �I, BETWEEN GUEST / L 2 DRB REVIEW 12 OCT WATER PROOFING I— GARAGE AND LEVEL 2 15 D NEW v—/o a LOUNGE-90 MIN. RATED / COMPOSITE3 PROGRESS/PRICIN 23 DEC DECK / 01 — �r * o _” — �— •� I 1� G2 15 ®,\ / / �� 4 CDs/PERMIT 21 JAN . 5-11” �- - XXX 16 2 / A201 2 / / NEW GLASS RAILING TO REPLACE WALL RAILING / i �� / UNIT / (TBD IN HOA INTERIOR FINISH PACKAGE) �� __ i, 203 re 1 , 1 / / / /'��� / mi .. .. / ❑ , / ❑ 1 \ j A210 5 d V I / Ft✓ DN ❑ t / 1 A203 ALT 1: GLU LAM BEAMS / / /' REMOVED. IF KEPT: GLU �I\� \/ LAM BEAMS TO BE V fr,./ REPAIRED AND RECEIVE 0 i' 2 FRONT COPPER PANEL WRAP / **REPLACE ALL WINDOWS AND DOC)Fr \ '// ENTRANCE/ REPLACE ALL SLOPED GLASS AND PRIVATE UNIT WINDOWS AND DOORBY / 8 ELEVATION CURTAIN WALL SYSTEM �. \ / OWNER / / _ ® \* I UNIT / STAIR TOWERS CLAD IN A408 A401 CORRUGATED CORTEN STEEL 103a PANELS // 1 1 1 \ ALL WOOD SIDI ,G TO BE 9 / _ — _REPLACED H 3 COAT STUCCO SYSTEM ANDNTIO /' UNIT J` 0 / CEMEUS TRIM O 202 \ GENERAL PLAN NOTES / / 4 /\ UNIT / �� 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. A21� ALL BAY WINDOWS TO KYNAR2. FURNITURE IS NIC, U.N.O. / / '107U I PAINTED CLADDING. SEE ELEVATIONS \ ® 3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER AND PERSPECTIVES FOR LOCATIONS \ NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT / BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D (r) /10 — i — / — \ I/ BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES w 0 \ AND GARAGE AND OTHER UNCONDITIONED AREAS. 2 J / / — , " 4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13. REPLACE (5)INSWING DOORS W/ 3 REPLACE INSWING PATIO DRS SLIDING GLASS DOORS, SEE O / /G W/SLIDERS, SEE SCHED. a 11 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE 0 WINDOW SCHEDULE, TYP. / UNIT / / 1 / DEPT-2 EXISTING BOXES ARE AT FDC LOCATIONS D 0 / / , -L" A201 ! 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL U 109U1L // I A205 K._ :: IMAKEUPAIRUNITS il Z/ / / z/ 7. A213 6 ® �: — — — — — — — — a a — SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR w 14 - •� — /, _ _ '� 13 SIZE AND LOCATION. 2/ \i/ `' \ / 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT ' / \\ , vPERPENDICULAR WALL SHALL BE 4" U.N.O. C/� m \� UNITUNIT9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES& Z / U r//k00 / GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. O O 109)J / 321 LL I - I - 204 - - - 206 — t — — BARRIER ON EXT. WHERE SIDING SHOWN). J / — • — 15 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE Q / / N� CONSTRUCTED ON A 5 1/2"x 6"CONC CURB, RE: X/A5.04. 7�� / / / / �� ` , ` / _ 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED © �'� / —= w� 8 \�� IN-KIND W/REGARD TO RATINGS, HARDWARE, AND FINISHES, OR / MI � �� \ �\ KEPT AS IS. DETERMINED CASE BY CASE SEE LOCATIONS ON NO 0 �'7° // 1 A212 O ° �`" 17 PLANS N- 0 °���, 0 ��� �.�1 �, 2 12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY PRECAST CONCRETE WALLS / 2 / / CONSTRUCTED TO MATCH EXISTING, U.N.O0 INTEGRAL COLOR SKIMCOATED A310 13. WHERE"CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM STUCCO S / ® 3 / A203 �,, Ai� / NOTED FROM FACE OF FINISH TO FACE OF FINISH. 10 14. ALL LOAD BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED �2` A210 / PER STRUCTURAL DRAWINGS �'' / 15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES)TO BE 1-HR STAIR TOWERS CLAD IN A B B 1 C D G H I J K / RATE OR MATCH EXISTING CORRUGATED CORTEN © O WESTERN RIB STEEL 1 16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR PANELS TRANSITIONS A204 ® 17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT LEVEL 2 PLAN BE LESS THAN 7 FEET(2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT LEVEL 2 FLOOR PLAN 18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 019. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR 1/16"= 1'-0" RATING, WHEN PART OF PARTITION ASSEMBL Project Number VSRP - 2016 Date 01 /21/2016 Drawn By MEW/DW Checked By MEW P Al 02 4N co O N Scale 1/16" = 1 '-0" N Page 3 of 23 CCO...% le'121 AN.' KY • . S A. Ilifti . ig— e.ii M. . 410..-472/..' (,) 6'6- D ;LAC O ® C) C OD E F G TT K 1/4.. .4; ....., , „ Lin _c„, ...c. . .L E REPLACE TRAFFIC COATING ON EXTERIOR 1 1 1 REPLACE TRAFFIC COATING ON EXTERIOR 1 1 1 Ito = a LANDINGS; REPAIR/REPAINT RAILINGS; COVER LANDINGS; REPAIR/REPAINT RAILINGS; COVER q) GLULAM WITH COPPER AND COUNTER FLASH GLULAM WITH COPPER AND COUNTER FLASH E UNDER TRAFFIC COATING UNDER TRAFFIC COATING 66.a = ..c 0 MI. _ -t=t :- ima Rep CU = . - . I ow) BUILDING STANDARD BUILDING STANDARD UTILITY DOOR UTILITY DOOR IIIMW—�' � 9 ° $ a aI 1 as d" /PI ° as - 4 ° , ° °a ,_ n , _° Q , - ° � �I 11.-iUNIT ° , - -. a , . N 1301LLIII - -' __- - ',-. 14-',-, ;d _ _ _ a ad �a a d ° ° 4 UNIT ° 302LL 303 dd°_ " „ e e n d °- d° J I ie, ° F UNIT 304 UNIT No. Description Date 1 PROGRESS/PRICIN 2 OCT e d a 306L UNIT a / p _ ° ISmiI d d S 4 G 15 ° ° ,d. , ed. °a a a a . , n ` r rnTr-F EGRESS STAIR TO BE REMOVED. w4ifir`\/ . 305LL II e a - P a ° ° 2 DRB REVIEW 12 OCT d-, ° _a _ 1 1 1 1 1 1 1 ALL CONNECTIONS TO BUILDING TO BATCHED. UNIT 700 07UL ° I 15 ' d $ °" ° _� + tl DOOR TO STAIR TO BE REPLACED WITH WINDOW. a a ni IL r/ 3 PROGRESS/PRICIN 23 DEC Qa G2 15 will ! / / / .4 .e a, . _ _ - , 7/ „ a _ , ' ' \ I �� 4 CDs/PERMIT 21 JAN A, d /e 4 - ° ,� 16 d - m d UNIT / / _° ,, 1 : , , ,_ : : ;,: ,,-,__:- :,_: '°- ' '''_ ': :4__.°, 308LL — „ _. -,...._ -, // AINT.OFFICE - IT 1 / / I I 313 / , 41) / / UN / /\ — — — / — / 311 / / / / / / 0 \,� / UNIT // Q / 7 1 1 310LL / UNIT / OED — — — — — — — — UNIT 315E / UNIT / 312 GENERAL PLAN NOTES /319 �� / 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. / N. / 2. FURNITURE IS NIC, U.N.O. / / NIT / / \ UNIT / 3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER U / ® NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT / 314LL BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D U) 317 L L `- 32'-6 1/4" 32'-6 1/4" 32'-6 1/4" 32'-6 1/4" — — ,-/ — �/ yBY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES LU ED — �;/ / / IIAI AND GARAGE AND OTHER UNCONDITIONED AREAS. 2 J / /�4 __ _ i �� _ ___ �_: _ 11 4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13. 0 _ / O 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE 0/ / / / UNIT UNIT UNIT UNIT J DEPT-2 EXISTING BOXES ARE AT FDC LOCATIONS / / 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL < 0 / 316LL 320LL 322LL 326LL BE COORDINATED WITH STRUCTURAL. il Z 0 / _ � _ 12 7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS / / / 0/ . / O SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR Q 14 - > - ` — — - �� I __ _ = 13 SIZE AND LOCATION. T O / I 1 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT/ \ PERPENDICULAR WALL SHALL BE 4" U.N.O. / / �� 0 .1 / / �, UNIT UNIT 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES& Z / / GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. O 0 / / /7- / _ / �L // — — 318 — 324 — — —\______)___yi1s BARRIER ON EXT. WHERE SIDING SHOWN). � J / / 0 BUILDING STANDARD %� 1 O 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE Q / UTILITY DOOR .` CONSTRUCTED ON A 5 1/2"x 6"CONC CURB, RE: X/A5.04. 0 / / / ` 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED / - ��i�� `,.� BUILDING STANDARD IN-KIND W/REGARD TO RATINGS, HARDWARE, AND FINISHES, OR / / � � /� � � � UTILITY DOOR KEPT AS-IS. DETERMINED CASE BY CASE -SEE LOCATIONS ON / BUILDING ' >�� �� 17 PLANS STANDARD �. ' O I— UTILITY DOOR 0 \- \,� \ �� 12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY VP ® / CONSTRUCTED TO MATCH EXISTING, U.N.O (1.) 0 0 / 13. WHERE"CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM ® QNOTED FROM FACE OF FINISH TO FACE OF FINISH. 14. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED 0 PER STRUCTURAL DRAWINGS / 15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES)TO BE 1-HR / RATE OR MATCH EXISTING 16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR TRANSITIONS OA OB B 1 C OD E F ElG H I J K 17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT LEVEL 3 FINISH BE LESS THAN 7 FEET(2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED PLAN BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBL 1OLEVEL 3 FINISH PLAN Project Number VSRP - 2016 1/16" = 1'-0" Date 01 /21/2016 Drawn By MEW Checked By MEW P N O A 1 1 3 Lii Lo N co O N Scale 1/16" = 1 '-0" N Page 4 of 23 . ... 4 Cl' eAdke. . eV: yip ON Si6 D A 0 O B1 C OD E 0 G H I J K .., 26'-8" .„..i= E / 26'-8" �'-0� 12'-0" 16'-0" / 25'-6" / 25'-6" / 19'-7" / 12'-8 3/4" / 14'-10 1/4" 5'-0" 12'-0" E c " 1O ZZZ — — BUILDING STANDARD 1 UTILITY DOOR BUILDING STANDARD � la_ UTILITY DOOR � 10 b a O — — — — — — l e mmei ' IP UNIT 501 1 / UNIT a d a n G. 504 UNIT No. Description Date O — — — — P - — — — — / — \� — 1 PROGRESS/PRICIN 2 OCT G 15 a - / — EGRESS STAIR TO BE REMOVED. 2 DRB REVIEW 12 OCT �® \� / 1.11 I Il ALL CONNECTIONS TO BUILDING TO BE PATCHED. UNIT 700 15 a. a .. /411,1111i, a ii DOOR TO STAIR TO BE REPLACED WITH WINDOW. 3 PROGRESS/PRICIN 23 DEC L <— — / — — — G2 15 � MI 4 CDs/PERMIT 21 JAN / \ I 1111.,: © 16 , / / \ / ,� / / / \ / I _ , 1 \ 1 UNIT / / r P / I UNIT / o a� 503 / A. / ,'�� O - - - - 1 _ � /I � ® \-\ 1510LL / / / -Y-, , / / 7 I 11A ' / ,� / GENERAL PLAN NOTES 512 \ �' / 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. ° \ 5711 1 / / 2. FURNITURE IS NIC, U.N.O. / Q °j, ® 3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER d ' / e a / NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT (f) III / BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D / — BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES w 10 / / AND GARAGE AND OTHER UNCONDITIONED AREAS. / / b,.-, / a /j� / n � 11 4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13. 2 0 / / / / 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE �/ / ® / �� UNIT UNIT UNIT UNIT DEPT-2 EXISTING BOXES ARE AT FDC LOCATIONS < D / / / / 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL 0 / / 516LL 520LL 522LL 526LL / / 1 � ( BE COORDINATED WITH STRUCTURAL. 0— Z Q / / / / 12 7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL BE/ — / — / — / — — — \,i /J = 13 SIZE AND LOCATION.COORDINATED WITH MECHANICAL CONTRACTOR FOR w O14 — —/ _ O / / �� �� 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT2 i/ JPERPENDICULAR WALL SHALL BE 4" U.N.O. (/� / / Ilprm / / UNIT 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES& Z Q / / 1\ �/ GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. O O / / BARRIER ON EXT. WHERE SIDING SHOWN). 4::::::( 0 / KKi� �� A 524 1 — J BUILDING STANDARD I 15 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE / CONSTRUCTED ON A 5 1/2"x 6"CONC CURB RE: X/A5.04. 0 / / 11 UTILITY DOOR / 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACEDZ > / / �►� \‘\\\ BUILDING STANDARD IN-KIND W/REGARD TO RATINGS, HARDWARE, AND FINISHES, OR/ � UTILITY DOOR KEPT AS-IS. DETERMINED CASE BY CASE -SEE LOCATIONS ON A /\ �/ 17 PLANS O CIL / O / m \/ \\�� 12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY VIP ® CONSTRUCTED TO MATCH EXISTING, U.N.O (...) ® / 13. WHERE"CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM ® Q NOTED FROM FACE OF FINISH TO FACE OF FINISH. 14. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED �'� PER STRUCTURAL DRAWINGS / 15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES)TO BE 1-HR / RATE OR MATCH EXISTING 16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR TRANSITIONS OA CDC)1 C OD E F G H I J K 17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT LEVEL 5 FINISH BE LESS THAN 7 FEET(2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED PLAN BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 0 LEy1,-o“EL 5 F I N I S H PLAN 19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBL Project Number VSRP - 2016 1/16" Date 01 /21/2016 Drawn By MEW Checked By MEW P i.,., A 1 1 5 LON CID r N Scale 1/16" = 1 '-0" N Page 5 of 23