Loading...
HomeMy WebLinkAboutcut sheets_8.pdfHiehest Efficiencv In Class The Lochinvar FTXL"" truly is a game-changer in the ways that matter most to contractors and their customers. With five models from 399,999 to 850,000 Btu/hr, FTXL represents a new generation of fire-tube technology, delivering tremendous installation flexibility, plus thermal efficiencies of 97% to 98%, depending on the model. *See back for efficiency by model. Plus, FTXL keeps you in complete control, from across town or across the country, thanks to the new CON·X·US mobile connectivity feature. yc;10 THERMAL EFFICIENCY Saves Monev on Fuel Costs! 3 -Year Fuel Savings 514,000 FTXL's 98% Thermal Efficiency is higher $12,000 SAVES s12,400 than any boiler in its class. Check out 5lo.ooo ~~~~~~~--~~~~- the potential savings! ss.ooo ~~~~~~~~~- 56, 000 54,000 52,000 so Fuel savings is based on a heating load of 19,000 therms per year being supplied by an 82% efficient boiler at the DOE National average for natural gas of $1. 09. EFFICIENCY 85% -· ,,,,. lll!. r 87% 94% FTXL98% a I "'"'l:ll> ... ~ ... lt'"'io.'"'r;:,•ll<t ivi.Gi. '-"i 1 "' v .. , iiUlii "'""->'ii "'"i.~•:tt"' l;i<lill. Mlf ,.,_,,, nuyvwii~i~ With the state-of-the art SMART SYSTEM™ control. FTXL is enabled for optional CON·X·US remote connectivity.* It provides outstanding functionality, using the unit's on-board control panel, or via a mobile connection from wherever you go! Text or e-mail status alerts sent to your computer or mobile device • . Monitor status ancf .re-pmsram con ·'.~-. 0 ThP lnc;t;1llPr'c; R11c;t FriPnrl SMALLEST FOOTPRINT 6.l SQ.FT. Saves Space! The installed footprint of an FTXL boiler is 20% to 30% smaller than competitive boilers. And zero clearance on both sides means FTXL can squeeze where other boilers can't! ft 0 BOILER CASCADE SIDE CLEARANCE !=''.':!cu Arroc:cl With the FTXL boiler the water, gas and venting connections are on the back of the unit. And for service, the FTXL's hinged top opens to put components and connections in easy reach! cent IC'Nt"IM~ ·-·--iu-i;JU GPM FLOW F::tc:v I nrh-N-1 ink"' Programmingi .:.h..iVt.:J i?/HJHt.:y: FTXL can operate over a wide range of flow rates, with very low pressure drop. Installing FTXL as a full flow {variable primary) system cuts installation time plus the cost of pipe and pumps needed for primary/secondary piping. Savings can run into hundreds of dollars! . ,.,,,.:;;; ,7 ·~· '~ -.. "'"'"' f;:ic:;r;:idp RPd11ndanrv Protects against Downtime! Up to eight FTXL boilers can oper· ate efficiently as a cascading system, with total inputs up to 6.8 MBtu/hr. Cascade redundan· cy helps ensure that the system will run with no downtime, because if the first "lead" boiler becomes non-operational, the second boilertakes the lead until the first is brought back online. load proven FTXL parameter sets onto a USB drive, and just plug into the port in the front panel to quickly upload them into the boiler. Reduces installation and programming time by up to 30 minutes per boiler! 1 >IDHU TANK@ ()HU CIRCO 7--- .REQUIRED ' ·~NG & HTG. Color-coded control display shows whether the system is functioning normally (blue), needs maintenance (yellow) or is in lockout mode {red). Can be programmed to display contractor's contact information. Venting Versatility! With FTXL you can easily meet any venting challenge. Room air venting or direct-venting, using PVC. CPVC, polypropylene or stainless steel vent pipe, up to 100 feet, plus common venting for multi-unit installations. 'lft_4 iU· I MODULATION TURN DOWN == = = -= ....... Room Air Vertical Common Vent ft ft ..... ,. ft t' '-UV...'- Room Air Sidewall Direct·Vent Vertical Direct Vent .:> Vertical w/Sidewalt Air Runs Smoothly on Cruise Control! Your car can automatically change speed as the road rises and falls, and FTXL can automatically modulate its firing rate as demand changes. When it's coldest outside, FTXSOO will fire at its maximum 500,000 Btu/hr rate. As it gets warmer and heat demand drops, it will gradually turn down to as low as 10% (50,000 Btu/hr). FTXL smoothly cruises through the day, with no frequent on/off cycling that can cause premature component failure. 26.25" -~~~ --'\ 53.5" 30.5" -33• Input NET AHR! HEX Model Min Max Thermal Output Rating Tum Flow (GPM) Water Number MBH MBH Efficiency MBH MBtf down Min Max Volume Water Vent Air Gas ShipeJng A B C D E F G H Conn. Size Intake Conn. Wt. (lbs.) FIX400(N,ll 40.0 399.9 98.0% 392 341 10:1 10 lOS 13 30-11r 2/.1/2" 10·1/4. ir 23·1/f 46-1/4' 39·1/2" 10-3i4' r 4' 4' 1" 435 FIX500IN,ll 50.ll 500.ll 91.7% 489 m 10:1 lS 105 12 J0.1/r 27·1/2" 10·1/4' 1r 23-1/4" 46-1/4. J'l.1/7' 10·3/4' r 4' 4' I' 460 Fll600(N,l) IS.ll 600.0 975% SIS 509 7:1 15 105 12 JO.l/T 27-1/r 10-1/4" ir 23-1/4" 46-1/4' 39.IJr 10-3/4' r 4' 4' l' 470 fTX725(H,ll 103.5 725.0 97.2% 705 613 7:1 10 150 II 33' 28-1/T lO·l/2" 17·1/T 7J.1/1' 48-1/Z' 41.1/4" Jr wr 6' 4" r SIO F1X850lM.ll ms 850.0 97.0% 82S 117 7:1 25 ISO 16 33' 78·1/2" 10-1/T 17.J/T 23-1/T 48-1/2" 41-1/4' 11" wr 6' 4• 1' 535 LEARN MORE, LOG ON TODAY TO \N\i'l!\N.ITXLBOILER.COM Vl:Locbinvar "uni '$%!@·• ~ ,Eiio au·· M BER Hi(,H [ f FJ(IENC-Y l50J LFPS t) WA rE f.t HE /~l l R'~ l'k_jit'-;,/ :'.' 1U-1:>0 GPM VARIABLE FLOW 1nn 5~~ FOOT INTAKE& 1w; i MODULATION lURNDOWN !.'::VU1.!1C'T I IXL WE HAVE THEM n 1 1 T ~• 1 1 a a n r-n r-n U U i i't U IYI D L. r\ I:. U .-..::-- ftOO/" 1u~- THERMAL SMALLEST FOOTPRINT 6.2 SO.FT. 0 SIDE CLEARAllCE ~ 0 BOILER CASCADE c;i::nl IS::Nf'll~U~ 0 MODELS ~ ENABLED FOR CON>~ US'" REMOTE CONNECT* *Purchased Separately -W:-Lochinvar' HIGH EFFICIENCY BOILERS & WATER HEATERS TYPE GAS Btu/hr INPUT FTXL Fire Tube Condensing Boiler Submittal Sheet FTX-Sub-01 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~- Btu/hr OUTPUT ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ NOTES . IJ. o v o.:.:i SMART SYSTEM FEATURES > Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial > loch-N-Llnk™ USB Thumb Drive Port for Easy Programming > Cascading Sequencer with Built-in Redundancy Selectable Cascade Type: Lead Lag/Efficiency Optimization Multiple Size Boilers Front-End Loading > 3 Reset Temperatures Inputs w /Independent Outdoor Reset Curves for Each Outdoor Sensor > Four-Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable-Speed Control Domestic Hot Water Boiler Pump Domestic Hot Water Recirculation Pump Control with Sensor > Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Input from Variable-Speed System Pump 0-10 VDC Modulation Rate Output Signal 0-10 VDC Enable/Disable Signal > Programmable System Efficiency Optimizers Space Heating Night Setback DHW Night Setback Anti-Cycling Ramp Delay Boost Time and Temperature > High-Voltage Terminal Strip 120 VAC/60 Hertz/I Phase Pump Contacts for J Pumps > low-Voltage Terminal Strip Building Recirculation Pump Start/Stop Building Recirculation Return Temp Sensor Contacts Proving Switch Contacts Flow Switch Contacts Alarm Contacts Runtime Contacts 3 Space Heat Thermostat Contacts Tank Thermostat Contacts System Sensor Contacts Tank Sensor Contacts Cascade Contacts 0-10 VDC BMS Contacts 0-10 VOC Boiler Rate Output Contacts 0-10 VOC Boiler Pump Speed Contacts 0-10 VDC System Pump Speed Contacts ModBus Contacts >Time Clock > Data logging Ignition Attempts Last 10 Lockouts Space Heat Run Hours Domestic Hot Water Run Hours STANDARD FEATURES > 97%-98% Thermal Efficiency > Modulating Burner with up to 10:1 Turndown Direct Spark Ignition Low NOx Operation Sealed Combustion Low Gas Pressure Operation >Stainless Steel Fire-Tube Heat Exchanger ASME-Certitied, "H" Stamped 160 psi Working Pressure 50 psi Relief Valve Combustion Analyzer Test Port Fully Welded Design > Vertical and Horizontal Direct Vent Direct Vent up to 100 feet PVC, CPVC, Polypropylene or AL29-4C Factory Supplied Sidewall Vent Termination > Smart System Control > Other Features On/Off Switch Adjustable High Limit with Manual Reset Automatic Reset High Limit Manual Reset Low Water Cutoff Flue Temperature Sensor Low Air Pressure Switch Temperature and Pressure Gauge Condensate Trap Zero Service Clearances !O·Year Limited Warranty Low Water Cutoff Custom Maintenance Reminder with Contact Info Password Security Customizable Freeze Protection Parameters OPTIONAL I PM ENT D CON-X-US Remote Connectivity D ModBus Communication D BMS Gateway to BACnet or LonMark 0 SMART SYSTEM PC Software D Alarm Bell D Motorized Isolation Valve D Wireless Outdoor Temperature Sensor D Multi-Temperature Loop Control D Variable-Speed Boiler Circulator liJ Constant-Speed Boiler Circulator fi!i:I Condensate Neutralization Kit D Concentric Vent K·rt (FTX400-FTX600) I&] Common Vent Kits D High and Low Gas Pressure Switches w/Manual Reset (FTXIOO-FTX850) D 30 psi ASME Relief Valve D 75 psi ASME Rel'ref Valve 0 100 psi ASME Relief Valve 0 125 psi ASME Relief Valve D 150 psi ASME Relief Valve > Firing Controls D M9-Standard Construction l)lJ MJ3-CSD-J/FM/GE Gap (FTX500-FTX850) FTXL Fire Tube Boiler Dimensions & Specifications E Air Inlet Electrical Connections D 2·1/2" .ooo. 000 53·1/2" ·~ Gas Connection I Water Outlet Water Inlet G ·--=:=:=:: ==:===--A l J B 40" f.---= 26·1/4" 65· 1/2" 9·3/4" 26·1/4"~ t Condensate Connection ~ 22·1/2" --, ____ A----- Input NET AHRI HEX Model Min Max Thermal Output Rating Turn Flow (GPM) Water Number MBH MBH Efficiency MBH MBH down Min Max Volume Water Vent Air Gas Shipp_ing A 8 C D E F G H c.onn. Size Intake Conn. Wt. libs.) FOR EASE IN ORDERING BY MODEL NUMBER FTX 850 N M13 This model is a 850,000 Btu/hr, natural gas FTXL Fire Tube boiler. It has M13 firing controls •Lochinvar® HIGH EFFICIENCY BOILERS & WATER HEATERS Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennt>ssee 37090 P: 615.889.8900 IF: 615,547.1000 11 C ml l!J Lochinvar.com 5/15---Prioted in L'.S.A.