HomeMy WebLinkAboutcut sheets_8.pdfHiehest Efficiencv In Class
The Lochinvar FTXL"" truly is a game-changer in the ways that matter most to
contractors and their customers.
With five models from 399,999 to 850,000 Btu/hr, FTXL represents a
new generation of fire-tube technology, delivering tremendous
installation flexibility, plus thermal efficiencies of 97% to 98%,
depending on the model. *See back for efficiency by model.
Plus, FTXL keeps you in complete control, from across town or across
the country, thanks to the new CON·X·US mobile connectivity feature.
yc;10
THERMAL
EFFICIENCY
Saves Monev on
Fuel Costs!
3 -Year Fuel Savings
514,000
FTXL's 98% Thermal Efficiency is higher $12,000 SAVES s12,400
than any boiler in its class. Check out 5lo.ooo
~~~~~~~--~~~~-
the potential savings! ss.ooo
~~~~~~~~~-
56, 000
54,000
52,000
so
Fuel savings is based on a heating load of
19,000 therms per year being supplied by an
82% efficient boiler at the DOE National
average for natural gas of $1. 09. EFFICIENCY 85%
-· ,,,,. lll!. r
87% 94% FTXL98%
a I
"'"'l:ll> ... ~ ... lt'"'io.'"'r;:,•ll<t ivi.Gi. '-"i 1 "' v .. , iiUlii "'""->'ii "'"i.~•:tt"' l;i<lill. Mlf ,.,_,,, nuyvwii~i~
With the state-of-the art SMART SYSTEM™ control. FTXL is enabled
for optional CON·X·US remote connectivity.* It provides
outstanding functionality, using the unit's on-board control panel,
or via a mobile connection from wherever you go!
Text or e-mail status alerts sent to
your computer or mobile device •
. Monitor status ancf .re-pmsram con
·'.~-.
0
ThP lnc;t;1llPr'c; R11c;t FriPnrl
SMALLEST
FOOTPRINT
6.l
SQ.FT.
Saves Space!
The installed footprint of an FTXL boiler is
20% to 30% smaller than competitive boilers.
And zero clearance on both sides means FTXL
can squeeze where other boilers can't!
ft
0
BOILER
CASCADE
SIDE
CLEARANCE
!=''.':!cu Arroc:cl
With the FTXL boiler the water, gas and venting
connections are on the back of the unit. And for
service, the FTXL's hinged top opens to put
components and connections in easy reach!
cent IC'Nt"IM~
·-·--iu-i;JU
GPM
FLOW
F::tc:v I nrh-N-1 ink"'
Programmingi
.:.h..iVt.:J i?/HJHt.:y:
FTXL can operate over a wide range
of flow rates, with very low pressure
drop. Installing FTXL as a full flow
{variable primary) system cuts
installation time plus the cost of
pipe and pumps needed for
primary/secondary piping. Savings
can run into hundreds of dollars!
. ,.,,,.:;;; ,7 ·~· '~
-.. "'"'"'
f;:ic:;r;:idp RPd11ndanrv
Protects against
Downtime!
Up to eight FTXL boilers can oper·
ate efficiently as a cascading
system, with total inputs up to
6.8 MBtu/hr. Cascade redundan·
cy helps ensure that the system
will run with no downtime,
because if the first "lead" boiler
becomes non-operational, the
second boilertakes the lead until
the first is brought back online.
load proven FTXL parameter sets onto a USB drive, and just plug into
the port in the front panel to quickly upload them into the boiler. Reduces
installation and programming time by up to 30 minutes per boiler!
1
>IDHU TANK@
()HU CIRCO 7---
.REQUIRED
'
·~NG & HTG.
Color-coded control display shows whether the system
is functioning normally (blue), needs maintenance
(yellow) or is in lockout mode {red). Can be programmed
to display contractor's contact information.
Venting Versatility!
With FTXL you can easily meet any venting
challenge. Room air venting or direct-venting,
using PVC. CPVC, polypropylene or stainless
steel vent pipe, up to 100 feet, plus common
venting for multi-unit installations.
'lft_4
iU· I
MODULATION
TURN DOWN
== = = -= .......
Room Air Vertical
Common Vent
ft ft ..... ,. ft t' '-UV...'-
Room Air Sidewall
Direct·Vent Vertical
Direct Vent
.:>
Vertical w/Sidewalt Air
Runs Smoothly on Cruise Control!
Your car can automatically change speed as the road rises and falls, and
FTXL can automatically modulate its firing rate as demand changes. When
it's coldest outside, FTXSOO will fire at its maximum 500,000 Btu/hr rate. As
it gets warmer and heat demand
drops, it will gradually turn down
to as low as 10% (50,000 Btu/hr).
FTXL smoothly cruises through the
day, with no frequent on/off
cycling that can cause premature
component failure.
26.25"
-~~~ --'\
53.5"
30.5" -33•
Input NET AHR! HEX
Model Min Max Thermal Output Rating Tum Flow (GPM) Water
Number MBH MBH Efficiency MBH MBtf down Min Max Volume Water Vent Air Gas ShipeJng A B C D E F G H Conn. Size Intake Conn. Wt. (lbs.)
FIX400(N,ll 40.0 399.9 98.0% 392 341 10:1 10 lOS 13 30-11r 2/.1/2" 10·1/4. ir 23·1/f 46-1/4' 39·1/2" 10-3i4' r 4' 4' 1" 435
FIX500IN,ll 50.ll 500.ll 91.7% 489 m 10:1 lS 105 12 J0.1/r 27·1/2" 10·1/4' 1r 23-1/4" 46-1/4. J'l.1/7' 10·3/4' r 4' 4' I' 460
Fll600(N,l) IS.ll 600.0 975% SIS 509 7:1 15 105 12 JO.l/T 27-1/r 10-1/4" ir 23-1/4" 46-1/4' 39.IJr 10-3/4' r 4' 4' l' 470
fTX725(H,ll 103.5 725.0 97.2% 705 613 7:1 10 150 II 33' 28-1/T lO·l/2" 17·1/T 7J.1/1' 48-1/Z' 41.1/4" Jr wr 6' 4" r SIO
F1X850lM.ll ms 850.0 97.0% 82S 117 7:1 25 ISO 16 33' 78·1/2" 10-1/T 17.J/T 23-1/T 48-1/2" 41-1/4' 11" wr 6' 4• 1' 535
LEARN MORE, LOG ON TODAY TO \N\i'l!\N.ITXLBOILER.COM
Vl:Locbinvar "uni '$%!@·• ~ ,Eiio au·· M BER Hi(,H [ f FJ(IENC-Y l50J LFPS t) WA rE f.t HE /~l l R'~ l'k_jit'-;,/ :'.'
1U-1:>0
GPM
VARIABLE
FLOW
1nn
5~~ FOOT
INTAKE&
1w; i
MODULATION
lURNDOWN
!.'::VU1.!1C'T
I IXL
WE HAVE THEM
n 1 1 T ~• 1 1 a a n r-n r-n U U i i't U IYI D L. r\ I:. U
.-..::--
ftOO/"
1u~-
THERMAL
SMALLEST
FOOTPRINT 6.2
SO.FT.
0
SIDE
CLEARAllCE
~
0
BOILER
CASCADE
c;i::nl IS::Nf'll~U~
0
MODELS
~ ENABLED FOR CON>~ US'" REMOTE CONNECT*
*Purchased Separately
-W:-Lochinvar' HIGH EFFICIENCY BOILERS & WATER HEATERS
TYPE GAS
Btu/hr INPUT
FTXL Fire Tube
Condensing Boiler
Submittal Sheet
FTX-Sub-01
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-
Btu/hr OUTPUT ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NOTES . IJ. o v o.:.:i
SMART SYSTEM FEATURES
> Smart System Digital Operating Control
Multi-Color Graphic LCD Display w/Navigation Dial
> loch-N-Llnk™ USB Thumb Drive Port for Easy
Programming
> Cascading Sequencer with Built-in Redundancy
Selectable Cascade Type:
Lead Lag/Efficiency Optimization
Multiple Size Boilers
Front-End Loading
> 3 Reset Temperatures Inputs w /Independent Outdoor
Reset Curves for Each
Outdoor Sensor
> Four-Pump Control
System Pump with Parameter for Continuous Operation
Boiler Pump with Variable-Speed Control
Domestic Hot Water Boiler Pump
Domestic Hot Water Recirculation Pump Control
with Sensor
> Building Management System Integration
0-10 VDC Input to Control Modulation or Setpoint
0-10 VDC Input from Variable-Speed System Pump
0-10 VDC Modulation Rate Output Signal
0-10 VDC Enable/Disable Signal
> Programmable System Efficiency Optimizers
Space Heating Night Setback
DHW Night Setback
Anti-Cycling
Ramp Delay
Boost Time and Temperature
> High-Voltage Terminal Strip
120 VAC/60 Hertz/I Phase
Pump Contacts for J Pumps
> low-Voltage Terminal Strip
Building Recirculation Pump Start/Stop
Building Recirculation Return Temp Sensor Contacts
Proving Switch Contacts
Flow Switch Contacts
Alarm Contacts
Runtime Contacts
3 Space Heat Thermostat Contacts
Tank Thermostat Contacts
System Sensor Contacts
Tank Sensor Contacts
Cascade Contacts
0-10 VDC BMS Contacts
0-10 VOC Boiler Rate Output Contacts
0-10 VOC Boiler Pump Speed Contacts
0-10 VDC System Pump Speed Contacts
ModBus Contacts
>Time Clock
> Data logging
Ignition Attempts
Last 10 Lockouts
Space Heat Run Hours
Domestic Hot Water Run Hours
STANDARD FEATURES
> 97%-98% Thermal Efficiency
> Modulating Burner with up to 10:1 Turndown
Direct Spark Ignition
Low NOx Operation
Sealed Combustion
Low Gas Pressure Operation
>Stainless Steel Fire-Tube Heat Exchanger
ASME-Certitied, "H" Stamped
160 psi Working Pressure
50 psi Relief Valve
Combustion Analyzer Test Port
Fully Welded Design
> Vertical and Horizontal Direct Vent
Direct Vent up to 100 feet
PVC, CPVC, Polypropylene or AL29-4C
Factory Supplied Sidewall Vent Termination
> Smart System Control
> Other Features
On/Off Switch
Adjustable High Limit with Manual Reset
Automatic Reset High Limit
Manual Reset Low Water Cutoff
Flue Temperature Sensor
Low Air Pressure Switch
Temperature and Pressure Gauge
Condensate Trap
Zero Service Clearances
!O·Year Limited Warranty
Low Water Cutoff
Custom Maintenance Reminder with Contact Info
Password Security
Customizable Freeze Protection Parameters
OPTIONAL I PM ENT
D CON-X-US Remote Connectivity
D ModBus Communication
D BMS Gateway to BACnet or LonMark
0 SMART SYSTEM PC Software
D Alarm Bell
D Motorized Isolation Valve
D Wireless Outdoor Temperature Sensor
D Multi-Temperature Loop Control
D Variable-Speed Boiler Circulator liJ Constant-Speed Boiler Circulator
fi!i:I Condensate Neutralization Kit
D Concentric Vent K·rt (FTX400-FTX600)
I&] Common Vent Kits
D High and Low Gas Pressure Switches w/Manual Reset
(FTXIOO-FTX850)
D 30 psi ASME Relief Valve D 75 psi ASME Rel'ref Valve
0 100 psi ASME Relief Valve 0 125 psi ASME Relief Valve D 150 psi ASME Relief Valve
> Firing Controls
D M9-Standard Construction
l)lJ MJ3-CSD-J/FM/GE Gap (FTX500-FTX850)
FTXL Fire Tube Boiler Dimensions & Specifications
E
Air Inlet Electrical Connections D
2·1/2"
.ooo. 000
53·1/2"
·~
Gas Connection I
Water Outlet
Water Inlet
G
·--=:=:=:: ==:===--A
l J
B
40"
f.---= 26·1/4"
65· 1/2"
9·3/4"
26·1/4"~ t
Condensate Connection
~ 22·1/2" --, ____ A-----
Input NET AHRI HEX Model Min Max Thermal Output Rating Turn Flow (GPM) Water Number MBH MBH Efficiency MBH MBH down Min Max Volume Water Vent Air Gas Shipp_ing A 8 C D E F G H c.onn. Size Intake Conn. Wt. libs.)
FOR EASE IN ORDERING
BY MODEL NUMBER
FTX 850 N M13
This model is a 850,000 Btu/hr,
natural gas FTXL Fire Tube boiler.
It has M13 firing controls
•Lochinvar®
HIGH EFFICIENCY BOILERS & WATER HEATERS
Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon, Tennt>ssee 37090
P: 615.889.8900 IF: 615,547.1000
11 C ml l!J Lochinvar.com
5/15---Prioted in L'.S.A.