Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Galvin #12 Fire Alarm.pdf
OF 1/4 111 CA.4 Vail Fire&Emergency Services 01/29/18 Commercial Specialist of Western Goforaato, LLC ROW HOUSE # 12 GALVIN RESIDENCE • B4512 - BOSCH FIRE / SECURITY PANEL • B942 - BOSCH TOUCH SCREEN KEYPAD • B208 - BOSCH 8-ZONE EXPANDER MODULE • CX4010 - BOSCH 12VDC TRANDFORMER • i3 SERIES - Two Wire, photoelectric i3 smoke detector with thermal sensor and built-in Temporal sounder. • COSMO-2W - Two Wire Combination Smoke / CO Detector with Built-In Temporal sounder • C01224T - Round, 12/24 Volt CO Detector Tim Ward NICET IV 115941 210 Marmot Lane#B5*PO Box 3913 *Eagle, CO 81631 Phone 970.328.1951 Fax 970.328.1956 www.cswcfi re.com OF zo Intrusion Alarm Systems I B4512 Control Panels 6 B4512 Control Panels -rvices www.boschsecurity.com BOSCH Invented for life 4....0 BOSCH 020 MODULE 1 0 ® O I .,. ti COMMUNICATION MODULE 1 ETHERNET fl09E-T o�p MAC ® BOSCH °`° °°"° , ► Supports up to 28 points using a combination of LINT hardwired or wireless points for installation dCI_ i f lexibilityand 2 areas with perimeter and interior Jumper Uder ax :�,°'. -. ° "" control COM II,;!°�° SDI2 ON HOABO POINTS OUTPUT Device Bus �pyMy RHO B VI open 37.5.0VDC g1rp,,, �ms ► On-board Ethernet port orConettix IP alarm Norma 2.0.90VOC 8 Short 0.0.1.9VDC 1W End ofU,e NBCMfore communication and remote programming, 18VAC i BATTFAV OUTPUTA.1 V+ 1 CAM 2 I3 COM 4I 5 COM B 17 COM 8 ` ® SEI :: Cr -,00:),:3000.)0(9.cou 6 ' compatible with modern IP networks including IPv6/ -�'! Ti:3c'D t)f3>^<l'7,')�3- IPv4,Auto-IP,and Universal Plug and Play ► Installer-friendly featuresforsimple installation and communications, including on-board USB for easy on-site RPS programming, plus supportforRemote Connect Service(not available in Europe,the Middle East,or Af rica),and plug-in PSTN and cellular communication modules f orsimple installation and communications ► Remote Security Control (RSC) app which allows users to control their security systems- and view system cameras- remotely f rommobile devices such as phones and tablets ► Programmable keypad shortcuts,situation sensitive on-screen help, and a bilingual user interface make system operation simple and easy The B4512 Control Panel integrates intrusion and With the B4512, you can monitor doors, windows, and residential fire,providing one simple user interface for motion within areas like showrooms or those that hold both systems. The B4512 provides up to 28 inventory.Each user can have a personalized individually identified points that can be split into 2 passcode, a wireless keyfob,and a credential to areas. control the system. The control panel can communicate through it's built- Use programmable authority levels with restricted in Ethernet port(not applicable to "E" control panels), privileges to provide service,security,and cleaning or through compatible plug-in modules that can send personnel with full or limited access. Use the three events over the public switched telephone network programmable outputs (expandable up to 27) to turn (PSTN) or over cellular network communications. on lights or lock and unlock doors. Users can: • Turn on the system to secure the stock room while you conduct daily business. • Perform tests to ensure your system is working properly. • Set your system to alarm immediately if a door opens. 69"1,:;# 2 I B4512 Control Panels • Activate the Watch featureso a tone sounds card,or the control panel can activa 6,' whenever a customer enters. reaction to a faulted point, or automat °.) • Set a schedule foryour system to automatically turn scheduled event (SKED). NO7 on at closing time. Vail Fire&Emergency Services • Use wireless security options to customize your Passcode security 01/29/18 system. • Two-man rule. Requires two people with two unique Central monitoring stations provide 24-hour system passcodes to be present at the time of opening. monitoring with access to vital services.Professional • Early ambush.Allows users to verify that the f acilityis security personnel can test the system, monitor saf e by requiring two passcodes. The control panel system activity,and alert the police,f iredepartment, sends a duress event if the user does not enter the or other emergency response teams if necessary. passcode a second time of terinspecting the premises. Functions • Dual authentication.Requires two f ormsof identification bef oreprocessing certain system Programmable outputs commands, including turning offthe system and • Three programmable on-board outputs;one high opening doors.A standard system user must have a current using a relay,and two trigger outputs passcode, a credential (token or card),and • Output A,with a contact rating of 3 Amps,can supply appropriate command authority permissions. up to 1.0 A total current f romAUX PWR • Outputs B and C sink up to 50 mA at 12 VDC Easy exit control • Four alarm output patterns The control panel changes f romone On (armed)state • Programmable bell test to another without turning off(disarming)the system. For example, if you change the state from Part On Point response (Perimeter Arm)to All On (Master Arm),the control • 20 custom point indexes panel complies and reports the change. Easy Exit • Selectable point response time Control reduces the number of keystrokes, simplifying • Cross point capability system operation. • Fire alarm verification • Dangerous gas indicator includes carbon monoxide Programmable passcode-controlled menu list (NFPA 720) Passcode-controlled shortcuts provide users only with • Watch mode the options and information pertinent to them, User interface simplifyingsystem operation. • Supervision of up to 8 keypads Flexible control • Custom keypad text is fully programmable through The system provides the f lexibilityto choose added RPS convenience or high security.For example,you can • Full function menu including custom functions restrict to a keypad's immediate local area turning on • Authority by area and 32 character name foreach (arming)and turning off(disarming)the system with a user passcode, even if the user has access to other areas. • 14 custom authority levels to restrict system features This is particularly usef ul f or high security areas, that each user can access where a user may have access to the area,but would • Programmable primary and secondary language by prefer to only turn of f(disarm)the area individually user and keypad;select from English,Spanish, French,and Portuguese rather than with the rest of the system. Area programming offers a wide selection of different Monitor Delay/DelayedResponse system configurations. Make area arming conditional Create a special point index that delays the reaction of on other areas(master or associate), if desired. You a point fora specif ied time (up to 1 hour in minutes can conf igureany area for perimeter and interior and seconds). This delay provides time f orthe arming, not requiringa separateareaforthis function. specified condition to reset beforeactivatingany For higher security applications,the Area Re-Arm annunciation.The system can annunciate locally and f eatureguarantees that areas are always rearmed,and send a report, if desired. When the system is armed, are disarmed for no longer than a specific, the point can respond like a normal point— providing configurable, amount of time (f orexample,service dual f unctionality.Use this featureto ensure that time). perimeter doors have not been propped open, or to Custom functions monitor critical areas such as computer rooms and For added convenience,the installer can program safes,forexample. custom f unctionsthat allow customers to complete System users complex tasks with one simple action. For example,a The system supports up to 32 users. Each user can custom f unction can bypass a group of points and arm have a personalized passcode, a wireless keyf ob,and a the system, allowing the user to perform these credential to control the system.You can assign functions with one easy command. Users can activate passcodes to one of 14 customized authority levels in custom functions with a keypad, keyfob,token, or each area and can be restricted to operate only during 3 I B4512 Control Panels .)410. certain times. Programmable primary and secondary '•' language by user and keypad;select from English, Notice, Spanish, French,and Portuguese. The Bosch Remote Connect service i �0 available in Europe,the Middle East or A .. Vail Fire&Emergency Services Communication formats 01/29/18 The control panel prioritizes and sends reports to f our Firmware updates route groups.Network and phone communications can The system allows remote firmware updates through use either the Modem4 or the Contact ID Remote Programming Software(RPS) using the RPS communications formats. Each group has a Firmware Update Wizard.The Firmware Update Wizard programmable primary and backup destination. uses the on-board USB connection or the on-board The control panel provides f lexiblecommunications for Ethernet(IP)connection (the on-board Ethernet port most central stations with reporting capabilities such is excluded on "E" versions)to transfer firmware as: updates. • Individual point numbers The control panel can optionally receive firmware • Opening or closing reports by user and area number updates f romRPS using a B426 Conettix Ethernet • Remote programming attempts Communication Module or a Conettix Plug-in Cellular • Diagnostic reports Communicator (B440/B441/B442/B443). Notice! IP communication Cellular firmware updates require more time than The control panel can use on-board Ethernet(IP) Ethernet updates and carrier data rates apply. connection (the on-board Ethernet port is excluded on • Control panel updates. Remotely update the control "E"versions)to communicate with a Conettix D6600 panel firmware foreasy featureenhancements or a Conettix D6100IPv6 Communications Receiver/ without replacing ROM chips. Gateway. • Module update support.Remotely update the The control panel can optionally use a Conettix Plug-in firmware on connected SDI2 modules foreasy feature Cellular Communicator(B440/B441/B442/B443). enhancements without visiting each individual Using Conettix IP communication offers a secure path module. that includes anti-replay/anti-substitution featuresand A wide variety of input options provides enhanced security with up to AES 256-bit Each point: encryption(using Cipher Block Chaining (CBC)). • Single 1 kO,single 2 kO, dual 1 kQ(1 kO+ 1 kO), and The control panel supports Domain Name System No EOL (end-of-line)(EOL) resistor options (for on- (DNS) for both remote programming and central board and B208 inputs) station communication. DNS provides ease of use, • Programmable for Fire,Intrusion,Gas, and eliminating the need to use static IP addresses as your Supervisory devices reporting destination, and accommodates a simple • Supports hardwired and wireless devices solution for central station disaster recovery. The • Supports IP cameras by Bosch as point and output control panel supports both IPv6 and IPv4 networks. devices Communication paths IP camera support The control panel accommodates up to four separate The control panel can integrate directly with Bosch IP phone and four separate network paths to the central cameras,using them as fully supervised points and station receiver. When resetting alarms or turning a outputs. system on and off,the user is identified by name and Integration of cameras allows the camera's video number. motion detection to activate points on the control panel.The control panel's virtual outputs can be Personal notification conf iguredto trigger camera actions, including The control panel can send text messages and emails sending video snapshots via email. for personal notification over Ethernet or using a cellular communicator.You can conf igureup to 16 Security and fire detection destinations using a combination of cellular phone The control panel provides eight on-board points, and numbers and email addresses. The control panel sends up to 20 additional off-board points (depending on notificationsin the user's programmed primary model and expansion interfaces).You can program language. individual points to monitor some types of burglar alarms,f irealarms,and supervision devices. Bosch Remote Connect(Cloud) Remote Connect simplifies connections f romRPS,and Event log the Remote Security Control app,using Bosch Cloud The event log stores local and reported events. The services.This service creates a secure connection to event log includes informationsuch as time, date, the control panel without specif icrouter settings or event, area,point, and user.View the event log f roma the need fora static IP address or DNS. keypad or use RPS to remotely retrieve event inf ormation.When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. 6,9".4%, 4 I B4512 Control Panels it Id CM O. V The log stores up to 127 local and reported events. Requirements to integrate Bosch VM 6,' Scheduled events(SKEDs) panel: ,)-11201. The internal clock and calendar start individually • A licensed Bosch VMS system using Pr. scheduled events (SKEDs).SKEDs perform several Editions v5.5 or higher or Bosch VMS Enterprise ggencyServices • Edition v5.5 or higher. 01/29118 functions such as turn on or off,relay control,or point • Expansion license to integrate the intrusion control bypassing. panel. One license needed per control panel.Order The control panel offers: number MBX-XINT-xxforthe expansion license added The control panel offers: to a Bosch VMS base license. Ref erto the Bosch • Five scheduled events with up to 25 different Video Management Softwareproduct page on the f unctions Bosch website,www.boschsecurity.com. • Two opening windows and two closing windows • Access to Remote Programming Sof tware(RPS). • Two user group windows • Day-of-week,date-of-month,or holiday only schedules Certifications and approvals • One holiday schedule of 366 days (leap year) Programming Region Certification Installers can perform limited programming on-site USA ANSI- CP-01-2010-Control Panel Standard- with a keypad (critical parameters; such as account SIA FeaturesforFalseAlarmReduction IDs, central station and RPS IP addresses and phone Australia RCM ACMA numbers, reporting formats,and more).They can also do full programming on-site or remotely(attended or Europe CE EMC,LVD,RoHS[B6512,B5512, unattended) with RPS.A programmable system B3512E,B4512,B4512E,B3512, B3512E] passcode prevents unauthorized remote programming. USA UL [B6512,65512,64512,63512] Diagnostics Keypads and RPS offer diagnostic help f or monitoring UL UL365-PoliceStationConnectedBur- and troubleshooting.The diagnostics featuresallow glarAlarmUnits you to view the status of the wired and wireless UL UL609-StandardforLocalBurglar devices. The f eaturesprovide the status of the control Alarm Units and Systems panel and its connected devices, such as firmware UL UL 636-Holdup Alarm Units and Sys- version, power,and missing conditions. View the terns status of each area. UL UL 985-Household Fire WarningSys- Remote Security Control app tem Units The Remote Security Control (RSC) app allows users UL UL 1023-Household BurglarAlarm Sys- to control their security systems remotely f romtheir tern Units devices. Users can: UL UL 1076-Proprietary BurglarAlarm • Turn their security system On or Off Units and Systems • Turn specificareas On or Of f • Control outputs for applications such as lighting UL UL 1610-CentralStationBurglarAlarm control Units • View live video from Bosch IP cameras UL UL 1635-StandardforDigitalAlarm • Grant access remotely by unlocking and locking doors Communicator System Units The app requires the installing dealer to create a CSFM see our website Remote Access Prof ilef or users, and to install the prof ileon their devices. FCC Part 15Class B Bosch Video Management System integration Canada ULC {B6512,65512,64512,63512] With Bosch Video Management System (Bosch VMS) ULC CAN/ULCS303-Local BurglarAlarm and an intrusion system, the VMS operator has a single Units and Systems user interface to monitor and control the intrusion Re- system combined with video surveillance.With Bosch ULC CANing C enter end- remisendard Burglaror Re ceivingCenterand Premise Burglar VMS and a control panel, the operator can,for Alarm example: ULC CAN/ULCS545-Residential Fire Warn- • View videos triggered by intrusion events, including ingSystemControlUnits all relevant informationsuch as areas,point,and user show in the display with the event. ULC CAN/ULCS559-Fire Signal Receiving • View areas,points, outputs,and doors—with their Centresand Systems statuses— on the Bosch VMS map, providing the ULC ULC-ORD C1023-Household Burglar exact location in the system. AlarmSystem Units • Turn on (arm)and turn off(disarm)areas. • Bypass andunbypasspoints. ULC ULC-ORD C1076-Proprietary Burglar Alarm Units and Systems CIF 16 5 I B4512 Control Panels ida Region Certification B99 USB DirectConnectCableb�' IC ICES-003-Information Technology B501-10 Interconnect wiring cables(packof10) I QD Equip ment(ITE) Vail Fire&Emergency Services Brazil ANATEL 04712-16-01855[B5512,B4512,and Detectors 01/29/18 B3512 when used with B430 or B442] FCC-380 Carbon Monoxide Detector Installation/configuration notes F220-P:Photoelectric Smoke Detector F-220-PTH:Photoelectric/Heat Detector • Notice Not all products and f eaturesare available in all FCP-OT320 Multisensor Detector Optical/Thermal regions.Consult your local Bosch representative FCP O320OpticalSmokeDetector f or availability details. FCH-T320 Heat Detector Keyp ads Bosch conventionaldetectors,including Professional Series,Blue Line 6942/B942WTouchScreen Keyp ad(SDI2) Gen2,Blue Line,Classic Line,Commercial Line,and Ceiling Mount motion detectors,as well as glass break,seismic,request-to-exit, B930 ATM Style Alp hanumericKeyp ad(SDI2) photoelectric,heat,and smoke detectors. B921CTwo-IineCapacitive Keypad(SDI2) Modules B920 Two-line Alp hanumericKeyp ad(SDI2) B201 2-wire PoweredLoop Module 8915/B9151Basic Keyp ad(SDI2) B208 Octoinp utModule Power B308 Octo-output Module CX4010 Plug-in Transformer(18 VAC 22 VA 60 Hz) B426 ConettixEthernet Communication Module ICP-TR1822-CAN Plug-in Transformer(110VACprimary,18VAC 22 VA B430 Plug-in Telep honeCommunicator secondary) B440 ConettixPlug-in Cellular Communicator(using 3G) DE-45-18 Transformer B441 ConettixPlug-in Cellular Communicator(using CDMA) D126 Standby Battery(12 V,7 Ah) B442 ConettixPlug-in Cellular Communicator(using GPRS) D1218 Battery(12V,18 Ah) B443 ConettixPlug-in Cellular Communicator(using HSPA+) D122 Dual Battery Harness B450 Conettix Plug-in Communicator Interface D122 Dual Battery Harness with long leads B520 AuxiliaryPowerSup p lyModule Enclosures B810 wireless receiver(RADION) B10 Medium Control Panel Enclosure B820 SDI2 Inovonics Interface Module B11 Small Control Panel Enclosure D113 Battery Lead Sup ervisionModule B12 Mounting Plate for D8103 Enclosure D125B Dual Class B Initiating Module B8103 Universal Enclosure(requiresa B12) D129Class A Initiating Module D8108AAttack ResistantEnclosure(requiresa B12) D130 Auxiliary Relay Module D8109 Fire Enclosure(requiresa B12) D132A Smoke Detector ReversingRelay Module D8108A-CEAttack Resistant Enclosurewith Built-in Transformer D133/D134 Relay Module (requiresa B12) D135A Low Battery Disconnect Module B-ENCL-1 Metal EnclosureKit(includes B12 and transformer) D185 ReversePolaritySignaling Module Accessories D192G Class"B",Style Y Bell Circuit Sup ervision B56 Keyp adSurface Mount Box Applications B96 Keyp adTrim Bezel Remote Programming Software(RPS or RPS-LITE)v6.03 and higher CIF 1°4 6 I B4512 Control Panels jia Bosch Video ManagementSystem v5.5 and higher EN1233D Necklace Pendant Transmitter(Double-4 Remote SecurityControl(RSC) EN1233S Necklace Pendant Transmitter(Single-butto 3Q0J Conettix receivers EN1235DBeltclipPendant Transmitter(Double-b MM&Emergency Services (Managed and configuredwith ConettixD6200 Programming/ EN1235DF Fixed-location Transmitter(Double-button) Administration Software v2.00) EN1235S BeltclipPendant Transmitter(Single-button) Conettix D6600 CommunicationsReceiver/Gateway(with only D6641 line cards installed)with CPU version 01.10.00 EN1235SF Fixed-location Transmitter(Single-button) Conettix D61001Pv6Communications Receiver/Gateway with CPU EN1247 Glass-break Detector Transmitter version 61.10.00 EN1249 Bill Trap Transmitter ConettixD6100i CommunicationsReceiver/Gateway with CPU version EN1242 Smoke Detector Transmitter 61.10.00 EN1260 Wall Mount Motion Detector RADIONwirelessfromBosch EN1261HT High Traffic Motion Detector B810 wireless receiver(RADION) EN 1262 Motion Detector with Pet Immunity RFBT-A/RFBT bill trap EN1265 360°Ceiling Mount Motion Detector RFDL-11-A/RFDL-11 TriTechmotion detector EN4200 Serial Receiver RFDW-RM-A/RFDW-RM recessed mount door/window contact EN5040-T High Power Repeater with Transformer RFDW-SM-A/RFDW-SM surfacemount door/window contact Technical specifications RFGB-A/RFGB glass break detector RFKF-A/RFKF two-button keyfob Communications RFKF-FBS-A/RFKF-FBS four-button keyfob Ethernet 10/100fu11 dup lex(N/Afor"E" control panels) RFKF-TBS-A/RFKF-TBS two-button keyfob Environmental considerations RFPB-SB-A/RFPB-SBsingle-buttonp anic Relative humidity 5%to 93%at+90°F(+32°C) RFPB-TB-A/RFPB-TB two-button panic non-condensing RFRP-A/RFRP rep eater Temperature(operating) +32°F to+122°F(0°Cto+49°C) RFSM-A/RFSMsmoke detector Number of... RFPR-12-A/RFPR-12 PIR motion detector Areas 2 RFPR-C12-A/RFPR-C12 PIR curtain motion detector Custom functions 2 RFUN-A/RFUN universal transmitter Events Up to 127 Inovonics Wireless Passcode users 32,plus 1 Installer p asscode B820 SDI2 Inovonics Interface Module Points 28(8 on-board,up to 20 off-board ENKIT-SD12 SDI2 Inovonics Interface and ReceiverKit.Includes B820 and virtual) and EN4200 Programmable outp uts 27(3 on-board,up to 24 off-board EN1210 Universal Transmitter(Single-inp ut) and virtual) EN1210E0LUniversal Transmitter with EOL Resistor RF points 20 EN1210W Door-WindowTransmitter with Reed Switch IP cameras 2 EN1215EOL UniversalTransmitter with Wall Tamp er,Reed Switch,and SKEDs 5 EOL Resistor EN1223D Water-resistant PendantTransmitter(Double-button) Power Requirements EN1223S Water-resistant PendantTransmitter(Single-button) Currentdraw(maximum) Idle 125 mA;Alarm 155 mA EN1224-ON Multip le-ConditionPendantTransmitter Outp ut(alarm) 1.3 A at 12 VDC idati OF pi 7 I B4512 Control Panels • iii•40. Outp ut(auxiliary,continuous 800 mA at 12 VDC nominal Battery,12V 7AhfP' o power,andswitchedauxiliary A rechargeable sealed lead-acid power ' 3q0- combined): a secondary power supply or in auxiliary o f unctions. Vail Fire&Emergency Services Voltage(operating): 12VDC nominal Order number D126 01/29/18 Voltage(AC): CX4010 UL Listed Class 2 Battery,12V 18Ah Transformer 18 VAC 22 VA 60 HZ The D1218 is a 12 V 18Ah sealed lead-acid battery Ordering information with two bolt-f astened terminals. It is used f orstandby and auxiliary power.It connects to a compatible IP control panel,28 points control panel using a D122 or D122L Dual battery Supports up to 28 points,3 on-board outputs, and 2 harness. areasforintrusion, residential f ire.On-board Ethernet. Order number D1218 Order number B4512 Transformer, plug-in,18V 22VA p Control panel,28 points,no IP For use in North America.110 VAC primary voltage The B4512E is available only in kits. input. 18 VAC,22 VA secondary input. For kits, refer to Quick Selection Guide(B Series Kits) Order number CX4010 on the Documents tab of the control panel's Product Transformer, plug-in,18V 22VA,Canada Page at us.boschsecurity.com. For use in Canada. 110 VAC primary voltage input. 18 Order number 84512E VAC, 22 VA secondary input. Accessories Order number ICP-TR1822-CAN Auxiliary power supply module, 2A 12V Universal enclosure,white Provides auxiliary power to 12 VDC devices or to SDI2 White steel enclosure measuring 41 cm x 41 cm x 9 cm modules. Order number B520 (16 in. x 16 in. x 3.5 in.). Order number B8103 2-Wire Powered Loop Steel enclosure,large,grey The module provides a single powered initiating device Grey steel enclosure measuring 41 cm x 41 cm x 9 cm circuit.The module supports compatible 12 V 2-wire smoke detectors. It also supports connecting burglary (16 in. x 16 in. x 3.5 in.). devices to the control panel. Order number D8103 Order number B201 Attack resistant enclosure,large,grey SD 128 Input Expansion Module Grey steel enclosure measuring 41 cm x 41 cm x 9 cm Provides 8 programmable inputs. (16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and Order number B208 key set. Order number D8108A SDI2 8Output Expansion Module Fire enclosure,16x16x3.5",red Provides 8 programmable relays. Red steel enclosure measuring 16 in. x 16 in. x 3.5 in. Order number B308 (41 cm x 41 cm x 9 cm). UL Listed. Includes a lock and RECEIVER-SDI2 key set. Receives RF signals from RADION transmitters, Order number D8109 repeaters, and glassbreaks. Operates at 433.42 MHz. Steel enclosure,medium,white For use with compatible SDI2 bus control panels. White, steel enclosure.Accepts an optional lock and Order number B810 tamper switch. Measures 35.6 cm x 31.8 cm x 7.6 cm Dual battery harness,17" 18AWG (14 in x 12.5 in x 3 in). Harness with circuit breaker. Connects two batteries Order number B10 (in parallel)to a compatible control panel. Order number D122 Steel enclosure,small,white White, steel enclosure.Accepts an optional lock and Dual battery harness,35",12V tamper switch. Measures 27.8 cm x 25.9 cm x 8.32 cm Harness with circuit breaker and leads measuring (10.9 in x 10.2 in x 3.3 in). 35 in. (89 cm). Connects two batteries(in parallel)to Order number B11 a compatible control panel in a separate enclosure. Mounting plate for D 8103 enclosure Order number D122L Required for mounting select control panels and other devices in B8103, D8103, D8108A, D8109, and BATB Battery Box enclosures. Order number B12 ki F zo 8 I B4512 Control Panels • it.•40. Transformer enclosure kit,grey Software Options '"' o For applications that might require a remote Upgrade DVD ji3q--Oc transformer in an enclosure.Can be used with B RPS software is available forf reedownlo. Series control panels and D9412GV4/D7412GV4 RPS product page. It is also available nll€'1jVDI iiabAncyServices control panels. Order number D5500CU 01/29/18 Order number D8004 Enclosure lock and key set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key. Order number Di01 TAMPER SWITCH 2/PKG Screw-on tamper switch that f itsall enclosures. Shipped in packages of two. Order number D110 TAMPER SWITCH-D UAL Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS USB direct connect cable Male A to Male A USB cable for local programming of control panels with on-board USB ports. Order number B99 Basic Keypad Two-line alphanumeric basic keypad with English f unction keys. Order number B915 LCD keypad,icon keys,SDI2 Two-line alphanumeric basic keypad with icon f unction keys. Order number B915I 2 Line Alpha Numeric Keypad(SDI2) Two-line alphanumeric keypad Order number B920 Two-line Keypad w/Touch keys,Inputs Two-line alphanumeric keypad with inputs and capacitive touch keys in black. Order number B921C ATM Style-Alpha Numeric Keypad(SD 12) Five-line ATM style alphanumeric keypad Order number B930 Touch Screen KP Prox/Input/Output, black Black SDI2 touch screen keypad with inputs and one output. Order number B942 Touch screen KP,prox/input/output,white White SDI2 touch screen keypad with inputs and one output. Order number B942W + CIF 4 ..,,PAppillif. 9 I B4512 Control Panels S C Z IA ril5 1207111 Vail Fire&Emergency Services 01/29/18 Represented by: Europe,Middle East,Africa: Germany: North America: Asia-Pacific: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH Bosch Security Systems,Inc. Robert Bosch(SEA)Pte Ltd,Security Systems P.O.Box 80002 Robert-Bosch-Ring 5 130 Perinton Parkway 11 Bishan Street 21 5600 JB Eindhoven,The Netherlands 85630 Grasbrunn Fairport,New York,14450,USA Singapore 573943 Phone:+31 40 2577 284 Germany Phone:+1 800 289 0096 Phone:+65 6571 2808 emea.securitysystems@bosch.com www.boschsecurity.com Fax:+1 585 223 9180 Fax:+65 6571 2699 emea.boschsecurity.com onlinehelp@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.asia ©Bosch Security Systems 2017 I Data subject to change without notice 7050304907 I en,V30,09.May 2017 CIF / 44-:Sk;04e Intrusion Alarm Systems I B942 Touch Screen Keypad B942 Touch Screen Keypad I -rvices I www.boschsecurity.com BOSCH Invented for life t BOSCH Area 1:Off Full Area Name ► Color graphic touch screen display uses a combination of simple icons and text for easy A ®BOSCH operation z Area 1:Off • F Full Area Name ► Built-in presence detector lights the display when Ready to turn all on user approaches keypad ► Built-in proximity reader allows use of a token or * F + R * •.. ;;; * ? „=ass card as replacementfora passcode, or foruse with dual authentication for high security areas (c•)) • ► Four inputs and one output provide cost effective expansion ► Slim, modern design blends with any decor The B942 keypad is an SDI2 bus compatible device. Functions The keypad f eaturesan illuminated touch screen and graphical interface. With an elegant design and low Display prof ile,the keypad f its with any modern decor. Each The touch screen display uses icons, words, numbers, keypad has user adjustable options such as volume and symbols to show the status of the security system and brightness.They have four inputs and one output. and forinteracting with the security system. When The keypad shows system messages f orall areas. several events occur,the keypad shows each event in order of priority. The keypad detects when a user System overview approaches and automatically activates the display. • For commercial use, install the keypad in building User icons and keys entrances and areas with unrestricted access. The keypad greets the user with a home screen that Mounting a keypad near exterior doors in hotel or shows the system status at one glance using a large business lobbies allows people to identify the type icon. The user can change the system status by simply and location of the emergency. touching this home screen icon. The touch screen • For residential use, install the keypad near the front display also offers icons on the ribbon bar.These and rear entrances to the home. Install additional visually pleasing graphical icons are easy to use for keypads in a kitchen or in a bedroom. accessing menus and other options. The keypad has a • Use multiple keypads in a large building with many variety of keyboardsforentering alphanumeric separate areas of security.Program multiple keypads characters. The keypad screen has numeric keys and to control multiple areas. one f unction[CMD] key.When pressed, keys emit a • Audible tones fromthe keypad sounder alert muted beep. Use the keyboards forentering personnel to f ireevents and assist f iref ightersin passcodes, activating commands, and entering locating the keypad. alphanumeric characters. lik" CIF 1°4 ..4...." . 2 I B942 Touch Screen Keypad c14.14 .11 rirt Audible tones Region Certification '' b' The keypad has a built-in speaker that produces O 1, several distinct warning tones. The tones are ULC CAN/ULCS304-Stan.. ! O. dif f erentiatedso that the user can recognize an event ceiving Center and Premise i . . Alarm Vail Fire&Emergency Services simply by hearing its associated tone.The keypad 01/29/18 backlight illuminates when it emits an audible tone. ULC CAN/ULCS545-Residential Fire Warn- Users can use a passcode or credential to silence the ing System Control Units tone. ULC ULC-ORDC1023-Household Burglar Status indicators Alarm System Units The status indicators on the keypad provide a quick ULC ULC-ORDC1076-Proprietary Burglar visual reference forsystem status. _ Alarm Units and Systems IC ICES-003-Information Technology ,/ The indicator lights when the system is readyto turn on(arm). Equip ment(ITE) i le The indicator lights when the system is on(armed). Installation/configuration notes /\ The indicator lights when there is a troublecondition. Power supply A compatible control panel supplies the power and GAS The indicator lights when dangerous gases are p resentincluding data requirements to the keypad through a four-wire carbon monoxide(NFPA 720). connection. it The indicator lights when the system has power. Mounting and wiring Mount in dry indoor locations. Includes a slim mounting plate for recessing wiring, Proximity reader and a surf acemounting plate f orsurf acemounting and The proximity reader allows users to use a token or card in place of a passcode to turn on or offthe wiring. security system.The proximity reader supports Compatible control panels EM4102 (125 kHz) credentials.The Bosch ACA-ATR13- B9512G/B9512G-E RFID tag and Bosch ACD-ATR111SO-RFID card are B8512G/B8512G-E examples. B6512 B5512/B5512E firmware v2.03 and higher Certifications and approvals B4512/B4512E firmware v2.03 and higher B3512/B3512E firmware v2.03 and higher Region Certification 1 D9412GV4/D7412GV4 v2.03 and higher Australia RCM ACMA Technical specifications Europe CE EMC,LVD,R&TTE,RoHS Properties USA UL UL 365-Police Station Connected Bur- glarAlarm Units Dimensions 6.2 in x 4.7 in x 0.65 in(158 mm x 120 mm x 16.5 mm) UL UL 609-Standard for Local Burglar Alarm Units and Systems Weight 11.3 oz(0.32 kg) UL UL 636-Holdup Alarm Units and Sys- tems Material Acrylonitrile butadienestyrene(ABS) Poly(methyl methacrylate)(PMMA) UL UL 985-Household Fire WarningSys- tem Units Displaywindow Touch screen UL UL 1023-Household BurglarAlarm Sys Multi line messages tem Units Indicators PowerindicatorLED UL UL 1076-Proprietary BurglarAlarm Status indicators Units and Systems Main icon UL UL 1610-CentralStation BurglarAlarm Warningand indicatingtones Units Inputs 4(four)1k 0 sup ervisedinp uts CSFM see our website Output 1(one)NO(normallyopen)contact FCC Part 15 Class B — Canada ULC CAN/ULCS303-Local BurglarAlarm Units and Systems lik" 4 3 I B942 Touch Screen Keypad C Environmental considerations Relative humidity 5%to93%at+32°C(+90°F)non- " -N0D condensing Vail Fire&Emergency Services Temperature(operating) 0°Cto+50°C(+32°F to+122°F) 01/29/18 Power requirements Currentwith proximity Standby:200 mA reader disabled Alarm:300 mA Currentwith proximity Standby:300 mA reader enabled Alarm:400 mA Voltage(input) 12 VDC nominal Wiring Terminalwiresize 18 AWG to 22 AWG(1.02 mm to 0.65 mm) SDI2 wiringwith p rox Maximum distance-wire size detectordisabled (unshielded wire only): 200 ft(61 m)-22 AWG(0.65 mm) 520 ft(159 m)-18 AWG(1.02 mm) SDI2 wiringwith prox Maximum distance-wire size detectorenabled (unshielded wire only): 150 ft(46 m)-22 AWG(0.65 mm) 390 ft(119m)-18 AWG(1.02 mm) Inputs and output On-boardp ointsvoltage Op en:2.2 to 5.0 VDC ranges Normal:1.4 to 1.8 VDC Short:0.0 to 1.0 VDC Short circuitcurrent:2.3 mA Relay contactrating 24 VDC,1 A,powerfactor:1 Ordering information B942 Touch Screen Keypad Black SDI2 touch screen keypad with inputs and one output. Order number B942 B942W Touch Screen Keypad White SD12 touch screen keypad with inputs and one output. Order number B942W Accessories B56 Keypad Surface Mount Box Surf ace mount box for mounting a keypad to concrete or block. Order number B56 B96 Keypad Trim Bezel Cover the wall footprint of previous keypads when replacing them with the new, slim design of B Series keypads.The white trim bezel is 8.6 in x 6.3 in x 0.12 in (22 mm x 16 mm x 3 mm). Order number B96 + CIF 4 ..e,PAppillif. 4 I B942 Touch Screen Keypad S 114 C Z IA ril5 1207111 Vail Fire&Emergency Services 01/29/18 Represented by: Europe,Middle East,Africa: Germany: North America: Asia-Pacific: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH Bosch Security Systems,Inc. Robert Bosch(SEA)Pte Ltd,Security Systems P.O.Box 80002 Robert-Bosch-Ring 5 130 Perinton Parkway 11 Bishan Street 21 5600 JB Eindhoven,The Netherlands 85630 Grasbrunn Fairport,New York,14450,USA Singapore 573943 Phone:+31 40 2577 284 Germany Phone:+1 800 289 0096 Phone:+65 6571 2808 emea.securitysystems@bosch.com www.boschsecurity.com Fax:+1 585 223 9180 Fax:+65 6571 2699 emea.boschsecurity.com onlinehelp@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.asia ©Bosch Security Systems 2017 I Data subject to change without notice 14472973195 I en,V11,17.Feb 2017 lik" 4 ;:r....." . Intrusion Alarm Systems I B208 Octo-input Module S .4 rirtZ B208 Octo-input Module ,Q 011 -rvices www.boschsecurity.com BOSCH Invented for life T_IBOSCH • 90,1 90,1 . B248 8_44_2 8_1412 - m'IP • 7.6' 3 76'r�'4 3 , of{. — uc� '4i TENS ONES yy "': a ,:.�� -uunduul, - a . • W4gel Programmable input point f unctions a a.y ..,rj _, ® ® Easy to read switch addressing I,'" 411) -,.-"r?;.nT-.("9):mr''> 1' ):::�.r)_'1 ', e), ,) ► 2 interconnect wiring connectors •7.4 W -_ " . „° ► Provides eight points • OCO'• • CC'0000000000 PW6 A B COM "WR1 COM 2 3 COM 4 5 COM 6 7 COM 8 The B208 Octo-input Module is an 8 point expansion Certifications and approvals device that connects to the control panel through the SDI2 bus.This module is fully supervised and • Certification communicates back to the control panel all point status changes.The module expansion points operate Australia RCM ACMA the same as the points on the control panel. Europe CE EMC,RoHS Industrial, commercial,and institutional facilitiesare USA UL typical installations for the B208 module. The B208 connects to the SDI2 bus on the control panel using UL UL 365-Police StationConnectedBur- SDI2 terminals,or using the interconnect cable.You glarAlarmUnits can connect multiple B208 modules to a single control UL UL609-StandardforLocalBurglar panel.The B208 address switches allow for ease of AlarmUnits and Systems — use in device addressing. UL UL 636-Holdup Alarm Units and Sys- System overview — terns UL UL864-StandardforControlUnitsand The B208 Octo-input Module connects to a control Accessories for Fire AlarmSystems panel through the SDI2 bus. This module is supervised UL UL985-HouseholdFireWarningSys- and communicates back to the control panel all point tem Units status changes.The module's expansion points operate the same as the points on the control panel. UL UL 1023Household BurglarAlarm Sys- tem Units Functions UL UL 1076-Proprietary BurglarAlarm Units and Systems Loop inputs The B208 uses up to eight inputs which may be UL UL 1610-CentralStationBurglarAlarm Normally Open (NO), or Normally Closed (NC) with 1k Units C2 EOL resistor(s)forsupervision. FM FM3010-FireAlarmSignalingSystems CSFM see our website lik" CIF 1°4 2 I B208 Octo-input Module W.% Region Certification Envronmental considerationsb 1111 FCC Part 15ClassBRelativehumidity 5%to 93%at+32°C QOJ FDNY- 6174 Temperature(operating) 0°C to+49°C(+32/Wivelgt elfiirgency Services CoA 01/29/18 FDNY 6196 Power requirements CoA Current 35 mA Canada ULC CAN/ULCS303-Local BurglarAlarm Units and Systems Voltage 12 VDC nominal ULC CAN/ULCS304-Standardfor Signal Re- Wiring ceivingCenterand Premise Burglar Alarm SDI2 wiring Maximum distance-Wiresize ULC ULC-ORD C1023-Household Burglar (unshielded wire only):1000ft(305 Alarm System Units m)-22 AWG(0.65 mm) ULC ULC-ORD C1076-Proprietary Burglar 1000 ft(305 m)-18 AWG(1.02mm) Alarm Units and Systems Unshielded wire only IC ICES-003-Information Technology Loop inputs Equip ment(ITE) Loop Inputs Up to eight inp uts.lnp utcontacts may Installation/configuration notes be Normally Op en(NO)or Normally Wiring considerations Closed(NC)with 1k0EOL resistor(s) The module to the control panel using the PWR,A, B, forsupervision.Note:NormallyClosed COM terminals on the control panel using the screw (NC)is not p ermittedin Fire terminal strip or the interconnect wiring connector. installations. Use 12 AWG to 22 AWG (1.5 mm to 0.6 mm) wires f romthe module to the control panel. Ordering information Compatibility B208 Octo-input Module For UL 864 compliance, use a UL commercial f ire Provides 8 programmable inputs. approved control panel. Order number B208 Controlpanels B9512G/B9512G-E(Upto59 modules) B8512G/B8512G-E(Up to 9 modules) B6512(Upto9 modules) B5512/B5512E(Up to 4 modules) B4512/B4512E(Up to 2 modules) D9412GV4(Up to 24 modules) D7412GV4(Up to 7 modules) D7212GV4(Up to 3 modules) Parts included Quar Component 1 Module 1 Hardwarepack 1 Interconnect cable 1 Installationmanual Technical specifications Properties Dimensions 2.5 in x 3.8 in x 0.60 in (6.37cmx9.6cmx1.5cm) + CIF 4 0 p i 0 0 c if. 3 I B208 Octo-input Module 0 S C Z IA ril5 iQ0]111 Vail Fire&Emergency Services 01/29/18 Represented by: Europe,Middle East,Africa: Germany: North America: Asia-Pacific: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH Bosch Security Systems,Inc. Robert Bosch(SEA)Pte Ltd,Security Systems P.O.Box 80002 Robert-Bosch-Ring 5 130 Perinton Parkway 11 Bishan Street 21 5600 JB Eindhoven,The Netherlands 85630 Grasbrunn Fairport,New York,14450,USA Singapore 573943 Phone:+31 40 2577 284 Germany Phone:+1 800 289 0096 Phone:+65 6571 2808 emea.securitysystems@bosch.com www.boschsecurity.com Fax:+1 585 223 9180 Fax:+65 6571 2699 emea.boschsecurity.com onlinehelp@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.asia ©Bosch Security Systems 2017 I Data subject to change without notice 2536957579 I en,V25,17.Feb 2017 44:N*;.°4* Intrusion Alarm Systems I CX4010 Plug-in Transformer e( 47, CX4010 Plug-inrmer e( 47, 31 „,4 -rvices 01 29 18 www.boschsecurity.com BOSCH Invented for life ► Provides eff icient,constant power forcompatible Iowa, control panels and modules MODEL : INPU120VA0NODA-22-1830VA 80Nz OUTPUT:IBVAC 1.22A 22VA OU` E49G]L 358 PANS LISTED GLAS52 TgM15E°PMEfl TDC PDWEF PPDDUCTS GO..LTD.01 The CX4010 is for use in North America.It converts 110 VAC primary voltage input to 18 VAC, 22 VA secondary input. Parts included Quantity Component 1 Transformer Technical specifications Rating 110VAC (primary) Rating 18 VAC,22VA (secondary) Color Black Ordering information CX4010 Plug-in Transformer For use in North America.110 VAC primary voltage input. 18 VAC,22 VA secondary input. Order number CX4010 ° CIF I/4 twill* Z SYSTEM _ . �$ SENSOR QOM Vail Fire&Emerg: cy Services 01/29/18 • SmokeDetectors with 1 r ' Sounder and Relay Option tion 1/21, go) System Sensori ''sounder and relay smoke detectors apply the guiding principles of installation ease, 3 intelligence,and instant inspection in a series of specialty conventional devices. Features Installation ease.Throughout the i3 series,installation is simple •85 dB sounder with its installer-friendly base and p lug-in design.The base accommodates a broad range of back box and direct mounting •Form C relay options and provides ample sp acefor pre-wiring the device.To •Isolated thermal sensor complete the installation,the i3 detector p lugs into its base with a simp le Stop-Drop'N Lock action. •Plug-in design(base included) Intelligence.To reduce the likelihood of nuisance alarms,all •In-line terminals i3 detectors are equip p edwith both drift comp ensation and •Flexible mounting options smoothing algorithms.These capabilities minimize both short-and •Stop-Drop'N Lock attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an i3 Ready' p ane(2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or •Remote maintenance signaling freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift compensation and smoothing algorithms the SENS-RDR disp lays the reading,in terms of percent-per-foot •Simplified sensitivity measurement obscuration,within seconds. •Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,i3 sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call for differentiating between a local and a general alarm,the i3 line offers an isolated thermal model,which ® c MEA MSFM EIY initiates a local alarm when smoke is detected,and a general alarm LISTED APPROVED I r�approved approved cC• US when the thermal sensor is activated. 3015195 7272-1653164 372-02-E 2133 3180932 k 14 IA CbSmoke Detector Specifications Z Electrical Specifications LED Modes tk OperatingVoltage Nominal:12/24V non-polarized LED Mode Green LED Red LED Condition ' I 11:1-1 2-wire:8.5 V to 35 V Power up Blink every Blink every 10 Initial LED 81- _ 4-wire:10 V to 35 V 10 seconds seconds status Vail Fire&Emergency Services Maximum RippleVoltage 30%of applied voltage(peak topealk indication 01/29/18 StandbyCurrent 2-wire:50 pA maximum average Normal Blink every 5 off 4-wire:50 pA maximum average (standby) seconds PeakStandbyCurrent 2-wire:100 pA Out of off Blink every 5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4-wire:4WTAB,4WTR-B:35 mA Power-Up Sequencefor LED Indication 4WTAR-B,4WITAR-B:50 mA **Direct Power(Non-Reverse Polarity):130 Condition Duration mA limited by panel.Reverse Polarity Power: Initial LED 80 seconds 30 mA for the 2WTA-B in alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MOD reversing relay alarm current. Architect/Engineer Specifications Alarm Contact Ratings 2-wire:n/a Smoke detector shall be a System Sensor i3 Series model number , 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling FormC Contact Ratings 2 A @ 30 V AC/DC Systems.The detector shall be a combination photoelectric/thermal PhysicalSpecifications equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2WTR-B),a combination sounder/relay(model 4VVTAR-B),or an isolated OperatingTemperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang, Operating H umidity 0 to 95%RH non-condensing and 4-inch square back boxes with a plaster ring,or direct mount to the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.The detector shall allow pre-wiring of the base and the Freeze Trouble 41°F(5°C) head shall be a plug-in type.The detector shall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 percent per foot as measured in the UL smoke box.The detector Input Terminals 14 22 AWG shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction Approximate Weight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control panel and and 4WITAR-B only) shall provide a loop testing capability to verify the circuit without testing each Mounting 311/z inch octagonal back box 4-inch octagonal detector individually.When used in conjunction with the RRS-MOD module, back box,single gang back box 4-inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall back box with a plaster ring,direct mount to be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information Model Thermal Wiring Alarm Current Model Description 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapter bracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA *--Th SYSTEM ®2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change Wthout notice.Vsit systemsensocmm for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. AOS-0348-004.6/09•#2170 kl CIF I/4 ic Z SYSTEM �$ SENSOR "110D 1111j ail Fi •ncy Services 01/29/ TM i4 Series Combination • CO/Photoelectric Smoke Detector Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i4 Series combines CO and smoke detection • Single device for CO and smoke detection that uses less wiring into one device,requiring less wiring and fewer back boxes than two separate devices.The i4 Series is compatible with i3(2WTA-B and fewer junction boxes or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i4 I nterfaceModule. easily replaced at end-of-life,resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i4 Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port External I R LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The • base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i4 Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station.Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms,reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. 1111) M1 Nc LISTED 5963 1653:0227 foto °F I/44. AOPIIIIIIVL i4 Series Combination CO/Smoke Detector Specifications ^'F Carbon monoxide(C0)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wir- 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoele. !, sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The det- dra0p have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically a. sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-4T Services box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector s al provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall providea means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Electrical Specifications Operating Voltage(VDC): Nominal:12/24;Minimum:8.5;Maximum:35 Maximum Standby Current: 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 NF Physical Specifications Dimension: Diameter:5.5 Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10—70°C(14—158°F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5"and 4"Octagonal;Single-gang;4"Square;2 x 4 3.5"and 4"round ceiling. Direct mount to wall or ceiling. Operation Modes/LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest®Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent ° CIF I/4 ..414111111114 Z i4 Series Interface and Reversing �° # Relay Module Vail Fire&Emergency Services 01/29/18 • • • The i4 Interface Module connects up to 12 detectors to a • • wide range of control panels using only 2 to 3 zones. It • also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i4 module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm control panels panel using only 2 to 3 zones:a smoke zone,a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i4 module can be used to alarm all sounders in detectors and 2WTA-B smoke detectors. compatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4WTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i4 detectorsto the panel Installation ease:The i4 Series Interface Module mounts to a • LED indication shows when a detector on the loop requires 411/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) blocks with durable SEMS screws ensure a reliable connection. It • I nitiatesthe EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i4 Interface Module allows i4 and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modules. smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 I nterf ace Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings U � Nc o L LISTED S911 1653:0228 et° °F 1/4/! (41 i4 Series Interface Module Specifications ^'F The i4 module shall be a System Sensor i4 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 8: rys 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square•. 01. Wiring connections shall be made by means of SEMS screws.The module shall provide4 LED indicators that blink or illuminate t. X300] communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The • shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed fire alarm contp41 04 Emergency Services capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on I DC loops and shall provi ea1oop testing capability(EZ Walk)to verify the initiating loop wiring. Electrical Specifications Module Operating Voltage(VDC): Nom.: 12/24;Min.:8.5(2-wire),10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61mA(max.),45mA(12V I n),26mA(24V I n); 4-Wire:52mA1(max.),37mA1(12V I n),22mA1(24V I n) Alarm Current2: 2-Wire: 181mA(max.),121mA(12V I n),64mA(24V I n); 4-Wire:78mA1(max.),57mA1(12V I n),34mA1(24V I n) Maximum Ripple Voltage: 30%of applied power Maximum AlarmThreshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V;Max.:Vin 1 Does not include current draw from attached detectors or EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04 Width:6.04 Depth:1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0-50°C(32-122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20-70°C(-4-158°F) Input Terminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Modes/LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble(13 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wire systems) SYSTEM3825 Ohio Avenue•St.Charles,I L 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product spechcations subject to change without notice.Visit systemsensor.com SENSOR' for current product information,including the latest version of this data sheet. vJ www.systemsensor.com CODS30302•11/13 14° °F I/4 tr4.11V14. CO1224A �r SYSTEM SENSOR' .•• NOD it Fire&Emergency Services ' X11129/18 C01224 Series • Carbon Monoxide Detectors with RealTest® C Technology �r C01224T 11111-111111i1"7" The System Sensor C01224T, C01224TR, and C01224A (Canada) Carbon Monoxide(CO)Detectors use a highly accurate and reliable electrochemical sensing cell to C01224TR provide early warning of dangerous CO levels. Features When dangerousamou nts of CO are detected,the C01224 Series CO detectors alert residents by sounding and flashing a temp • A 10-year end-of-life timer 4 signal alarm.With 24/7 central station monitoring,residents are • RealTest®enables a functional test using canned CO guaranteed p rotectionwhether they are away from home,sleeping, • A code-required trouble relay or already suffering from the effects of CO. • Wiring sup ervisionwith SEMS terminals The C01224 Series detectors are designed for system operation. • 12/24 VDC These detectors are fully listed to UL 2075(US models only)and • A low current draw of 20 mA in standby and 40 mA in alarm CSA 6.19-01 (Canada model only)and offer a code-required trouble relay to send a sensor failure or end-of-life signal to the control • Versatile mounting for wall and ceiling panel and the central station.The CO1224 Series detectors also • Accurate and reliable electrochemical sensing technology use SEMS-typ eterminal Philips head screws for quicker and more • Optional CO-PLATE CO Detector Replacement Plate to upgrade positivewiring connections and code-required wiring sup ervision. p reviouslyinstalled comp etitordetectors to the CO1224T or With a low current draw,these detectors enable more devices to be CO1224A. connected to the panel,limiting the need to p urchaseextra p ower sup p liesor more exp ensivep anels.As 12/24 VDC detectors,the • CO1224T tested up to 12,000 feet above sea level C01224 Series detectors will operateon most industry security and fire alarm control panels. With RealTest®technology,the CO gas sensing cell used in the C01224 Series CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720:2009(US models only). Simply p utthe detector into RealTest mode,sp raya small amount of CO into the detector perthe installation instructions,and within seconds the detector will alarm,indicating successful gas entry.(See the reverse p age or the user manual for complete instructions.) Agency Listings U Note:C01224Ti& L °" C01224TR are in full 5 iN ° O comp liancewith UL 2075 and C01224A is LISTED in full comp liancewith E307195 E304075 ULC CSA 6.19-01. °F 1/4/! z CO1224 Series Detectors Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide(CO)detector shall be a system-connected System Sensor model number C01224T or C01224TR listed to. 4 11 Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The Canadian model CO1224A,is ULC listed to CSA 6.19-01, • -a-- carbon monoxide alarm devices.The detector shall be equip p edwith a sounder and a trouble relay.The detector's base shall be ableg• mount to a single-gang electrical box or direct(surface)mount to the wall or ceiling.Wiring connections shall be made by meowi�jg'iEergency Services screws.The detector shall p rovidedual-color LED indication that blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the p anel.When the detector gives a trouble or end-of-life signal,the detector shall be rep laced.The detector shall p rovidea means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately up onsensing CO entry.For the C01224T only, the detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time sp ecfied by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts permillion(ppm),as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size:C01224T&C01224A Length:5.1 in(130 mm),Width: 3.3 in(84 mm),Height: 1.3 in(33 mm) Size:C01224TR Diameter:6.0 in(152 mm),Height: 1.3 in(33 mm) Approximate Weight C01224T&C01224A:7 oz(198 g);C01224TR:11 oz(312 g) Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal(standby) Blink 1 perminute — Alarm — Blink in temp 4 p attern Sound in temp 4 p attern RealTest®Feature: The System Sensor C01224 Series CO Detectors enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. NOTE:Check with - 2. 11111 local codes and the AHJ to determine if a functional gas test is desired for an installation. Push and hold theTest/Hush button for Sp raycanned CO agent into the Verify CO sensing at the control panel. two seconds to enter RealTest mode.The detector. The detector will automatically exit green LED will flash once every second to RealTest alarm mode after about 20-60 indicate RealTest mode has started. seconds. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes(exceptin RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. End-of-Life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel to indicate it is time to rep lacethe detector.An electrochemical CO detector lifesp an is about ten years. The detector must be rep lacedby the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint(when necessary) of previously installed competitive carbon monoxide detectors that require replacement. Ordering Information CO-PLATE Part No. Description C01224T 12/24 volt,6-wire system-monitored carbon monoxide detector with RealTest®Technology(USonly) C01224TR 12/24 volt,6-wire system-monitored round carbon monoxide detector with RealTest®Technology(USonly) CO1224A 12/24 volt,6-wire system-monitored carbon monoxide detector with RealTest®Technology(Canadaonly) CO-PLATE CO detector replacement p lateto cover the footprint of previously installed competitive detectors(US&Canada) SYSTEM US:3825 Ohio Avenue Canada:6581 Kitimat Rd,Unit 6 Mississauga,Ontario L5N 3T5 ©2016 System Sensor.Product sp ecfications subject to St.Charles,IL 60174change without notice.Visit our websites for current product SENSOR® 800-SENSOR2 800-SENSOR2 information,including the latest version of this data sheet. systemsensor.com systemsensor.ca CODS88600.10/16 .„00104v10 O F P4.1 .,,, IR iri .,,kir toi Ac ,R ox ..., .2§. 0 ACCESSORY CABINET ENCL i ihn Vail f BY SPACE AGE ELECTRONICS 01129%18& Emergency Services Manufactured from 16 gauge steel and finished in a black powder coat, these massive enclosures are engineered to provide maximum quality that meets and exceeds industry expectations. Every surface-mounted cabinet provides efficient field installation of building control equipment and is ideally suited for easy wiring inspection. The front access door is recessed within the enclosure to protect it from damage, and can be hinged to the left or right side of the cabinet as well as securely -�. locked. A removable document holder sits inside the door to provide space for records, programs, and software, and a tamper switch can be mounted to the top or bottom of the enclosure to monitor the door position. Field Configurable Also included is a raised 1/2" galvanized back-plate with a hole Hinge Mounting matrix configured for field installed control equipment, wiring terminations, and labeling. Secured within the 8" deep enclosure by 4-8 mounting studs, this back-plate has ample space and convenient wire knockouts to make every installation fast and clean. . . ._ _. FEATURES - Recessed, selectable door hinge --"---. CAT45 keyed lock Selectable tamper switch Removable Field Configurable Removable document holder Document Holder Tamper Switch - EMT and rigid 1.75" and 2.5" cluster knockouts • 16 gauge steel construction ,p ow,yfo MPSO- OP"- -i 4dirb 90 -mu"- LISTED Pg.1/2 ° OF P4 < 24" < t % ti 24" SPECIFICATIONS 4 497 IS Z Constructed of 16 gauge (.059"thick) cold rol 414;1. bis 24 finished with a durable powder coat. Field-sele O,, �07 X05' - @right hinged door with a CAT45 keyed lock seated i 36" ACE2436 a flange supported on four sides. Enclosure fornFrfl wency Services ii door to protect from damage. Door includes removable V documentation sleeve. Enclosure has up to eight EMT and rigid 1.75" and 2.5" cluster knockouts embedded in sides of back box. Removable back-plate constructed of 16 gauge 91 T (.059" thick) galvanized steel with hole matrix to mount field devices. Back-plate fabricated to support four sides and 1/2" clearance depth and secured with 3/8"-16 studs. Back box 30" - has 2 ground lugs. Door and back box have green ground strap A • -- with lugs. Door has tamper switch to electrically monitor door position. Custom equipment can be mounted using standard hole matrix or self tapping drill screws. • 36" ACE3036 a AGENCY APPROVALS UOXX.S2580 UL Listed Control Unit Accessories 1 BACK-PLATE SIZES Part# Width Height Depth < 30" ACE2424 21" 20" 0.5" A ; ACE2436 21" 32" 0.5" ACE3036 27" 32" 0.5" ACE3048 27" 44" 0.5" c a ORDERING INFORMATION 48" - ACE3048 - Part# Description ACE2424 24"x24"x8"Accessory Cabinet Enclosure, Black ACE2436 24"x36"x8"Accessory Cabinet Enclosure, Black ACE3036 30"x36"x8"Accessory Cabinet Enclosure, Black ACE3048 30"x48"x8"Accessory Cabinet Enclosure, Black ,• MrSPACE AGE ELECTRONICS www.lsae.com 1 toll free 1.800.486.1723 1 fax 508.485.4740 M NEMAREISO 9001 Rea ©Copyright 2016 Space Age Electronics, Inc.I This document is subject to change without notice I LT10681 I Rev.A NM' COMPANY Pg.2/2