HomeMy WebLinkAboutE16-0014 Gear Submittal.pdf illi ENCOREelectric Montaneros Meter Stack Replacement 641 West Lionshead Circle Vail, Colorado 81657 1 Gear Submittal for Approval Encore Job # 16305 ENCOREelectric Gear Submittal for Approval Specification Section: Division 26 February 25,2016 Montaneros Meter Stack Replacement 641 West Lionshead Circle Vail, Colorado 81657 Contractor: Encore Electric,Inc. 2107 W. College Ave. Englewood,CO 80110 Contact: Eric Bankert (303)934-1234 Encore Job# 15301 141 ENCOREelectric Reviewed By Debele at 2/25/2016 17:40 ENCORE electric Gear Submittal for Approval Specification Section: Division 26 Submittal Approval Sheet ***PLEASE USE THE SPACES BELOW FOR COMMENTS AND STAMPS*** X REVIEWED REVISE AND RESUBMIT REJECTED FURNISH AS CORRECTED Corrections or comments made on the shop drawings during this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for:confirming and correlating all quantities and dimensions: selecting fabrication processes and techniques of construction: coordinating his work with that of all other trades:and performing his work in a satisfactory manner. Date: February 29, 2016 By: Stanton O. Humphries, PE Architectural Engineering Consultants, Inc. EE D Consolidated Electrical Distributors, Inc 2405 W. 5th Avenue Denver CO. 80204 Phone: 303-623-1233 Fax: 303-623-2266 February 25, 2016 TO: Encore Electric ATTN: Toby Debele PROJECT: Montaneros Thank you for the order. We will do our best to service it properly and ask for your help with the following: Attached is 1 set of submittal drawings for the above referenced project. Please review them and advise us of any discrepancies. These drawings are for approval. Please return one stamped approved original set to us with your release. If approved drawings can not be returned, a letter or email will suffice referring to this order and stating "Waive approved drawings, release as ordered." TYPE QTY DESCRIPTION MANUFACTURER RMS 1 TYPE RM RESIDENTIAL SWITCHBOARD AMP TENANT 21 BRH2125 22KAIC 2P 125A BREAKER EATON MAINS r'� AMERICAN MIDWEST TOWERdB MVIVIAIVLRVJ !.1.1171.8: ""�"'��" CUSTOMER: TO3131 VICKSBURG LANE PO BOX 47036 C/O ENCORE ELECTRIC X M131 MOUS MINNESOTA 55447 SMAC Ai+P DRAWN BY: DATE: SCALE: PHONE (763) 551-1555 FAX (763) 551-9275CSTOMER X °R' °eECP 02 25 16 1:1 NMBER: THIS DRAWING AND THE ,RMATION THEREON ARE THE PROPERTY OF AMERICAN MIDWEST -— AND ARE NOT TO BE COPAGE REPRODUCED, OR DISCLOSED TO OTHERS WITHOUT THE EXPRESS WRITTEN CONSENT OF AMERICAN MIDWEST POWER. 1 of 1 TOP VIEW 140000000f m ® ®®®®® 0 4F: ® ®®®®® 0 f ® ®oowa a=gars* 0 1 10 OcaieeMuc brs® ® I 0 Ocawcomec ars® ® I ®3/4"/ /1-1/4"O io ®3/4/1"/1-1/4"O 03/4"/1"/1-1/4"O UNE TOP FRONT VIEW SECTION: 1 SECTION: 2 SECTION: 3 SECTION: 4 8M MAIN 81.1 51.1 • tla "r ., S ® ® ® 12.00" a a UNE " a" " 2-500MCM ® 2O 0.4-1 PER PH do N ® O 0 03 ® O al M IC) (7)Ei CD C) S III II C.) S aa El ) (7) ED c5—-t...t—El i ( � ❑ 72.00" a v 1 .f *M a 'V 54.00" ® O CI)® \IQQ-�( En (31 m 0 0 --� )1,� U —v—__Ls# 'CLASS T ,SERVICE INSCONNECI Ie s I I o I II "o "".II MEM Milia 6.00" 30.00" I 20.00" I 30.00" I 30.00- 110.00* 1- 28.00"--1 1--20.00"--11---213.00"---1 28.00"--1 6.75" OPEN TOP & UNE TOPI OPEN TOP & OPEN TOP & —/ 8.75' 9.50" BTM. LOAD BTM. LOAD BTM. LOAD I 18.00" I PLAN VIEW TYPE RM RESIDENTIAL SWITCHBOARD SPECIFICATION BILL OF MATERIALS FRONT ACCESSIBLE CLASS 1. NEMA 1, DEADFRONT. VENTILATED mu QTY CATOLOG NUMBER DESCRIPTION SUPPUER CONSTRUCTION FORMED GALVANIZED CABINET WITH 16GA. STEEL 1 1080°�'� 800A/3PFILE swlral w/aAss 1'Fuses ABB PAN FORMED COVER PLATES PRIMED AND PAINTED ASA 81 GRAY.PLATED 2 21 HQ45 ST 13M LEVER BY—PASS METER SOCKET LANDIS BUS U.L LISTED AND LABELED AS SUITABLE FOR SERVICE ENTRANCE 3 21 x 123q/4P 22KAIC CRCUIT BRFAICER x EQUIPMENT PER U.L STANDARD 891 FAULT CURRENT RATING UP TO 4 85.000 W/MAIN; 60HZ 600 AMP BUS. NOTES: 1 I I IWC I woe 101 Bussmannt T-iron® Very Fast Acting Fuses JJN Class T 300 Volts, 1-1200 Amps Dimensional Data All (±002) ."`` .41•Dia. 3.06" (±0.02) (±0.04) 30A .8 2.03" .88"" .88" • ,- (±0.02 Elmo IRON ,,r, .56'Dia. 1.25• (±0.02) (±0.04) JS-20: 3SA to 60A 450A to 600A 484" (Typ.2) 411111 2,16' 3.38" .• _ (±0.02) (±0.04) 284" 1.56" 2.22" �„... (Typ.2) .84" 1 .92' t .]III (±002) 4 70Ato100A Mill111111i1.2,"4, 2.44' 0.0 Catalog Symbol: 1.1 N (1 69?) 601Ato 800A (Ty62Z) Current Limiting (Typ.2) .84" 4. 0111101 .0.0 Very Fast Acting (±0.02) (±0.04) Ampere Rating: 1 to1200A 110Ato200A 1.08"H Voltage Rating: 300Vac (or less)* _____�±0.04 Interrupting Rating: 200,000A RMS Sym. .406" .8" 1111111(±ti."04) Agency Information: (Typ.2)f llmni 1. UL Listed, Std. 248-15, Class T, Guide JDDZ, File E4273 (t0.04) 609" CSA Certified, C22.2 No. 248.15, Class 1422-02, File 53787 22saeo400A 8O1Ato1200A (Typ.2) Catalog Numbers • Small, space-saving fuses provide a high degree of current 11N-1 JJN-So 11N-250 limitation on short-circuits for excellent component protection I 11N-2 11N-3 11N-60 11N-300 JJN iso • Commonly applied in electric heat circuits, load center, JJN-10 disconnect switches, and meters. 11N-6 JJN-80 11N-400 • The small size of the T-Tron fuses permits installation in JJN-10 JJN-90 JJN-450 panelboards and control centers for system upgrading when 11N-15 JJN-100existing circuit breakers cannot safely interrupt larger available JJN-20 J1N-110 JJN-600 short-circuit currents. 11N-25 JJN-125 JJN-700 • High speed of response for semiconductor protection. 11N-30 JJN-150 JJN-800 11N-35 JJN-175 JJN-1000 JJN-40 11N-200 JJN-1200 11N-45 11N-225 — Recommended fuseblocks for Carton Quantity and WWglht-/JN•FTRON(300Vtac) 11111104. Class T 300V fuses Catalog Carton Weight" See Data Sheet: 1115 Number Qty. Lbs. Kg. 1-30 10 0.12 ' 0.054 35-60 10 0.23 0.104 70-100 5 0.36 0.163 110-200 1 0.14 0.063 225-400 1 0.25 0.113 450-600 1 0.44 0.200 700-800 1 0.80 0.363 1000-1200 1 1.45 0.658 '15-600A rated 160Vdc,601-1200A rated 170Vdc and 10 KAIC. -Weight per carton. CE CE logo denotes compiance with European Union Low Voltage Directive (50-1000Vac,75-1500Vdc). Refer to Data Sheet:8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 111101 Form No.11N COOPER Bussmann Page 1 of 2 3-17.04 SB04092 Data Sheet: 1025 • Loadcenters and Circuit Breakers let Type BR Loadcenters and Circuit Breakers BR Circuit Breakers Contents I Description Page „' Overview. V1-T1-41 I - - t J. BR Specialty Products f Spa Panels V1-T1-56 Riser Panel . . . . . . V1-T1-57 ,_. Type BR Renovation Loadcenter V1-T1-58 !:.'z•- ;} Type BR Retrofit Interior Kits . . .. . , . . , . . V1-T1-67 ' I t BR Circuit Breakers Yl Product Selection V1-T1-70 - IIli Circuit Breaker Accessories. . . . V1-T1-78 10 Wiring Diagrams V1-T1-80 BR Circuit Breakers Product Description Plug-On Branch Feeder Type Plug-On Combination Type Plug-On Ground Fault Circuit The figures are shown with i Arc Fault Circuit Breakers, Arc Fault Circuit Breakers, Breakers,Typo GFCB and a 120/240 Vac,single-phase, Type BR-10 kAlC,120 Vac Type BR-10 kAIC,120 Vac GFEP-10/72 kAlC,120 Vac three wire power source, and 120/240 Vac and 120/240 Vac and 120/240 Vac but are also applicable to a A branch feeder type arc fault A combination type arc Ground Fault 120/208 Vac,three-phase, circuit interrupter is a device fault circuit interrupter is a Application Notes four-wire power supply. intended to mitigate high device that includes all of Single-pole GFCBs are For all figures,the electrical current arcing faults in the the protection offered by the designed for use in two- operation of the GFCB is complete circuit, including branch feeder AFCI(mitigation wire, 120 Vac circuits.See not affected by the connected cords.Highof high current arcing faults in Page V1-T1-80 for a typical equipment ground. current arcing faults can the complete circuit,including wiring configuration. occur from line to neutral or connected cords). In addition Non-CTL Plug-On Replacement line to ground.These arcing it provides direct detection of Two-pole GFCBs are —Circuit Breakers,Type BRD— faults are in parallel with thepersistent low current arcing designed for use in three- 10kAIC,120/240 Vac load and produce the most faults down to 5 amps with wire, 120/240 Vac circuits, Non-CTL 10 kAIC energy of all arcing faults. associated mitigation of 120 Vac multiwire circuits for Replacement fire hazards in the cords employing common, neutral Purposes Only The branch feeder type AFCI rP connected to the outlets.High and two-wire,240 Vac For replacement in is required in the 1999 and current arcing faults can occur circuits obtained from a p 2002 National Electrical Code. enclosures manufactured from line to neutral or line to 120/240 Vac source. The Combination TypeAFCI is ground.These arcing faults prior to 1968 with unnotched Page V1-T1-80 shows typical stabs.Circuit breakers do required in the 2005,2008,and are in parallel with the load 2011 National Electrical Code. and produce the most energy wiring configurations for a not have rejection tab. of all arcing faults.The current 120/240 Vac mul0 Vac level of low current arcing circuits,and a 240 Vac,two- faults is limited by the load. wire circuit.Note the "panel neutral"conductor connects to the neutral bar,even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit. Volume 1—Residential and Light Commercial CA08100002E—January 2013 www.eaton.com V1-T1-69 1 e Loadcenters and Circuit Breakers 2 1 Type BR Loadcenters and Circuit Breakers 1 Product Selection Plug-On Circuit Breakers,Types BR-10/22/42 kAIC,120 Vac,120/240 Vac and 240 Vac BR120 Type BR Breakers,1-Inch(25.4 mm)per Pole 120/240,10,22 and 42 kAIC Two-Pole 120/240 Vac Single-Pole 120/240 Vac Common Trip Requires Two Requires One 1-Inch(25.4 mm)Space 1-Inch(25.4 mm)Spaces I . 10 per Shelf Carton 5 per Shelf Carton 10 kAIC 22 kAIC 10 kAIC 22 kAIC 42 kAIC Ampere Wire Size Range Catalog Catalog Catalog Catalog Catalog } 0gt Rating Cu/AI60°Cor75°C Number Number Number Number Number BR215 10 #14-4 BR110 — BR210 — — 15 #14-4 BR115 BRH115 BR215(4) BR11215 — 20 #14-4 BR120`k= BRH120 BR22O BRR220 — 1.11.1".,,101174 25 #14-4 BR125 BRH125 BR225r% BRH225 — 30 /14-4 BR130 BRH130 BR230' BRH230 — • 35 /14-4 BR135 BRH135 BR235(i) BRH235 — 40 #14-4 BR140 BRH140 BR240'- BRH240 4 — BR320 45 #14-4 — BRH145 BR245''- BRH245 — 50 #14-4 BR750 BRH15g BR250�' BRH250'� — 55 414-3 BR150 BRH155 BR255 BRH255 — 111111 60 /8-1/0 BR100 BRH160 BR260 8RH260 BRHH260 70 #8-1/0 BR17D BRH170 BR270 BRH278 BRHH270 80 #8-1/0 — — BR280 $RH2JlD BRHH280 IBM* 90 #8-1/0 — — BR290 BRH290 BRHH290 1111 100 #8-1/0 — — BR2100 BRH2100 BRHH2100 110 #8-1/0 — — BR2110 BRH2110 BRHH2110 125 #4 2/0 — — 11=25tib fIMS 150 #4-2/0 — — BR2150 _ _ Notes One pole,1-inch(25.4 mm)per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads.Add suffix H to catalog number. Switching duty rated. 4' On the black handle breaker,add suffix"B"to the catalog number to obtain a tapped molded opening for proper use with hold-down kits. :> For use as a branch circuit breaker in 400 and 600 ampere panels only. All Type BR single-,two-and three-pole circuit breakers carry listing for HACR application.For circuit breakers with a shunt trip,add ST suffix. V1•T1-70 Volume 1—Residential and Light Commercial CA08100002E—January 2013 www.eaton.com