Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E16-0014 plans approved.pdf
Town n f Vaii ELECTRICAL LEGEND TYPICAL 2 BEDROOM PANEL i TYPICAL 1 BEDROOM PANEL R; PROJECT:MONTENAROS ENGINEER: SOH PROJECT:MONTE NAROS ENGINEER SOH PROJECT:MONTENAROSMETERBANK ENGINEER: SOH PROJECT*:16022 VOLTAGE: 120,208V,1P,3W PROJECT*:16022 VOLTAGE: 120f20EV,1P„3W PROJECT#:16022 VOLTAGE: 120/208V.3P,4VV -_' , o• - ) (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) MOUNTING:RECESSED MAINS: 125A MLO MOUNTING:RECESSED MAINS: 125A MLO MOUNTING:SURFACE MAINS: 600A MAIN w F ,-; }l TYPE:00 RESIDENTIAL AIC: 10K TYPE:QO RESIDENTIAL AIC: 10K TYPE:PER SPECIFICATIONS AIC: 10K u ` 1, 1 0 RECESSED OR SURFACE DOWNLIGHT ABBREVIATIONS PHASE L 1 PHASE PHASE _ PHASE - I IFHASE I _1. . __. - PHASE �,� i Ui U G FI UR DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION DESCRIPTION 8 BKR P CIR CIR PBKR A B DESCRIPTION DESCRIPTION A B C PCIR CIR P BKRA B CDESCRPTION e l , 711-I WALLMO NTEDLI HT XT E AC ABOVECOUNTER I IMA 20I6 AFF -ABOVE FINISHED FLOOR SPACE 0 1 20 1 11 2 2 40 4000 RANGE SPACE 10 20 2 2 40 4000 RANGE PANEL 210 12250 125 •2 1 2 12 125 15500 PANEL 402 RECESSED FLUOR.LIGHT FIXTURE AFG ABOVE FINISHED GRADE I �_ JL i H SPACE 0 20 1 3 4 4000 SPACE 0..__ 20 1 3 4 _ 4000 2 BEDRM - 12250 3 4 1 13500 14 BEDRM I SURFACE FLUOR.LIGHT FIXTURE AHJ -AUTHORITY HAVING JURISDICTION BASE BOARD HEAT 938 _ 4 20 5 6 1 20 1500 KITCHEN PLUGS BASE BOARD HEAT 625 20 2 6 11 20 1500 KITCHEN PLUGS PANEL 208 12250 125 2 S 6 12 `925 12250 PANEL312 i 1 TOW e 7 r Aa AL ALUMINUM __ _ 938 17 8 1 20 1000 BATH HEATER 625 I 7 8 11 20 1000 BATH HEATER 2 BEDRM 12250 __._ 17 8 I 12250 2 BEDRM 1 1 ) ' N. l �I FIXTURE DESIGNATIONS: CU -COPPER - - - P EC ELECTRICAL CONTRACTOR BASE BOARD HEAT 938 20 2 9 10 1 20 1500 KITCHEN PLUGS BASE BOARD HEAT 625 20 2 9 10 11 20 1500 KITCHEN PLUGS PANEL 206 12250 125 2 9 10 2 125 11000 PANEL 311 UPPER CASE FIXTURE TYPE LOWER CASE-SWITCH DESIGNATION EM -EMERGENCY 938 11 12 1 20 1000 FRONT BATH HEATER 625 {1 11 12 1 '20 1000 FRONT BATH HEATER 2 BEDRM 12250 1 1 12 1 11000 1 BEDRM GC GENERAL CONTRACTOR BASE BOARD HEAT 938 20 2 '13 14 1 20 1000 DISHWASHER BASE BOARD HEAT 625 20 2 13 14 1 20 1000 DISHWASHER PANEL 204 12250 125 2 13 14 12 125 1 250 PANEL 310 Cl) O j�/ SHADING ON FIXTURE INDICATES EMERG.BATTERY BACKUP GND -GROUND ” 938 15 16 1 20 1000 LIVING ROOM PLUG 1 " MIN 625 1=16 1 20 MI 1000 LIVING ROOM PLUG 2 BEDRM 12250 15 16 12250 2 BEDRM N GFI -GROUND FAULT INTERRUPTER BASE BOARD HEAT 938 20 2 17 18 j 1 20 1000 DISPOSAL BASE BOARD HEAT 1625 20 2 17 18 1 20 1000 DISPOSAL PANEL 202 13000 125 2 17 18 2 125 12250 PANEL 308 C U W `- 1 I FLUORESCENT STRIP FIXTURE _ - - ------ I (� N MC MECHANICAL CONTRACTOR 938 19 20 1 20 _ 1000 BATHROOM PLUG I 625 19 20 1 20 1000 BATHROOM PLUG 3 BEDRM 13000 119 20 I 12250 '2 BEIORM _ +• -V r- 1 n n I TRACK LIGHT AS NOTED OR SCHEDULED NIC -NOT IN CONTRACT 0 21 22 0 0 21 22 0 NL NIGHT LIGHT PANEL 305 12250 _'125 2 21 22 -2 125 -13000 PANEL 408 - N.0 CD c0 CO WALL WASHER NTS NOT TO SCALE - 023 24 0 �0 24 1 0 2 BEDRM 12250 23 24 13000 .3 BEDRM Cl) (q 1.13.:1- 0--.--E1 )�t J-.-Lj POLE-MOUNTED FIXTURE PC -PLUMBING CONTRACTOR 0 25 26 0 0 25 126 0 PANEL 304 12250 125 2 125 26 12 125 13000 PANEL 406 C C U O~ REF REFERENCE 0 27 28 0 p I.27 128 0 2 BEDRM 12250 127 28 I 13000 3 BEDRM _ O • POST(BOLLARD)FIXTURE UG -UNDERGROUND 0 129 30 0 0 29 30 0 _ 0 ® STEP LIGHT UNO UNLESS NOTED OTHERWISE 10 131 32 0 0 31 32 I 0 PANEL 302 12250 125 2 . 30 12 125 13000 PANEL 404 Q 07 t- UTP -UNSHIELDED TWISTED PAIR 3 BEDRM 122 0 131 32 13000 3 BEDRM C •• 0�1 CEILING OR WALL MOUNTED EXIT LIGHT O 133 34 0 {0 33 34 0 PANEL 312 12250 125 2 33 34 12 125 13000 PANEL 412 I C > R3 0 WP WEATHER PROOF -{ C-p 1 0 35 36 0 0 35 36 0 I Q LL • EMERGENCY BATTERY LIGHTS XFMR -TRANSFORMER - 2 BEDRM I 12250 135 _36 13000 3 BEDRM 'L _ +18" -MOUNTING HEIGHT TO CENTERLINE 10 37 38 0 I -- ,0 37 38 , 0 - - PANEL 211 111000 125 2 [37 38 12 125 12250 PANEL 411 43 : 84 (a Igc DUPLEX RECEPTACLE @ 18"UNLESS NOTED OF DEVICE AFF OR AFG 0 39 40 I 0 I 0 39 140 0 U r O 0 41 42 0 -� 10 41 42 0 -' 1 BEDRM 11000 - _•_ 39 40 I ,12250 2 BEDRM 0 J. N N 1 t� DOUBLE DUPLEX RECEPTACLE @ 18"UNLESS NOTED SPACE 0 1 41 42 12 125 13000 PANEL 410 C Q)LC) U FIRE ALARM SYSTEM I 11 "- • co (I) QQ FLUSH FLOOR DUPLEX RECEPTACLE I I I LOAD CALCULATION SUMMARY OBSERVED ON SITE 2/26/2016 LOAU C ALCULA'1'YJN SUMMARY OBSERVED ON SITt 2/26Q016 0") U u),6 co ® SPECIAL OUTLET AS NOTED FACP FIRE ALARM CONTROL PANEL 30 LINEAR FEET OF ELECTRIC BASEBOARD 20 LINEAR FEET OF ELECTRIC BASEBOARD LOAD CALCULATION SUMMARY Cu_,,,7:5t. Cc DUPLEX RECEPTACLE HALF-SWITCHED @ 18"UNLESS NOTED (ANN] FIRE ALARM ANNUNCIATOR PANEL CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: f 5 W 0.94 0.95 CALCULATED POWER FACTOR: f CD J Ni 06 O @ POP-UP RECEPTACLE Q FIRE ALARM PULL STATION CCNNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS 0.93 156 W CO d7 - Iiiii TELE-POWER POLE D ALARM HORN OR SPEAKER APPLIANCES 0 0 0 0 APPLIANCES 0 0 0 0CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS I L•- -•§ >-, APPLIANCES 0 ) 0 0 = (13 3 N MULTI-OUTLET PLUG STRIP DIE COMBINATION HORN/STROBE OR SPEAKER/STROBE LIGHTING&RECEPT. 7000 34 4400 21 LIGHTING&RECEPT. 7000 34 4400 21 j -I--' U (1)= C 147000 407 54390 151 MECHANICAL 9500 46 9968.75 48 MECHANICAL 7000 34 7312.5' 35 LIGHTING&RECEPT. 0 •>= V 0 C 0 OH JUNCTION BOX IN FLOOR,CEILING OR IN WALL •H THERMAL HEAT DETECTOR KITCHEN OVEN&DRYER 8000 38 8000 38 KITCHEN OVEN& DRYER 8000 38 8000 38 MECHANICAL 206000 671 76220 248 I ©)KITCHEN OVEN&DRYER 168000 465 62160 172 0 ?Q TI V COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL •I SMOKE/IONIZATION DETECTOR TOTAL 24500 118 22369 108 TOTAL 22000 106 19713 �_ _ 95 "� 0 I ( - TELEVISION OUTLET •P PHOTOELECTRIC SMOKE DETECTOR "' 0 Q CC)l— c) TOTAL 521000 1544 192770 571 -C 0) C ' N © TELEPHONE BACKBOARD •H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR TYPICAL 3 BEDROOM PANEL TYPICAL 4 BEDROOM PANEL Q -.4 - CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING n a DUCT DETECTOR MONTENAROS RESIDENCES METERBANK > CIRCUIT HOMERUN 0 SPRINKLER SYSTEM FLOW SWITCH PROJECT:MONTENAROS ENGINEER: SOH PROJECT:MONTENAROS ENGINEER: SOH PROJECT#:16022 VOLTAGE: 120208V,1P,3W PROJECT#:16022 VOLTAGE: 120/208V,1P,3W Demand Load Calculations - - - CONDUIT RUN BELOW FLOOR OR GRADE MA- SPRINKLER SYSTEM TAMPER SWITCH MOUNTING:RECESSED MAINS: 125A MLO MOUNTING:RECESSED MAINS: 125A MLO (Per NEC Article 220 Parts I-III,Optional calc 220.82) ] CONDUIT STUB-UP-CAP&MARK D- STROBE TYPE:QO RESIDENTIAL AIC: 10K TYPE:QO RESIDENTIAL AIC: 10K 21 UNITS owrn rzr I 1PHASE PHASE PHASE 1 _ 1 PHASE UNIT#S 202,204,206,208,210,211,212 ,y` ''_lyfl� ht/-1'1,-;,,,:N` LIGHT SWITCH AT 46 UNLESS NOTED Q SMOKE/FIRE DAMPER CONNECTION DESCRIPTION A B P CIR P BKR A �M�DESCRIPTION DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION 302,304,306308,310,311,312 'c`~' SUBSCRIPTS: , $' C 0 H ((" 2=2-POLE SWITCH REMOTE INDICATOR LIGHT ,-- , 3=3-WAY SWITCH SPACE 0 120 + 4000 RANGE SPACEI 12402,40d,406408,410 411,412 .47.. C' e y 4=4-WAY SWITCH SECURITY SYSTEM10all -T 20 1 1 2 40 4000 RANGE .) f SPACE i t 4000 SPACE 0 20 1 3 4 4000 •M=MOTION-OPERATED SWITCH BASE BOARD HEAT 1125 1120 1500 KfTCHEN PLUGS BASE BOARD HEAT 1250 20 2 5 6 1 20 1500 KfTCHEN PLUGS Quantity Volt-Amps Demand Total(VA) yK=KEY-OPERATED SWITCH DC CONTACT DOOR SWITCH IN JAMB OR HINGE 1 1000 BATH HEATER " 1250 7 8 11 20 1000 BATH HEATER General41 �� e' O=THERMAL OVERLOAD SWITCH P INTRUSION MOTION DETECTOR AS SPECIFIED CORRIDOR/ROOM 5 c ``T � BASE BOARD HEAT 112 t 1500 KrrCHEN PLUGS BASE BOARD HEAT 1250 20 2 9 10 1 20 100 KITCHEN PLUGS Dwelling and Square footage 25840 `C -VJ i r CO "-- P P=SWITCH WITH PILOT LIGHT C OR R 1125 1000 FRONT BATH HEATER " 1250 11 12 �1 20 1000 FRONT BATH HEATER General&Lighting(1st 3 KVA) 1000 SF X 3 X 100% = 3000 4'' S ,, Yti D DIMMER SWITCH W/WATTAGE BASE BOARD HEAT 20 2 13 14 1000 DISHWASHER BASE BOARD HEAT 1250 20 2 11 20 1000 DISHWASHER General Lighting(Remainder) 24840 SFX 3 X 35% 25082Y rJ < 0 KEY-OPERATED ACCESS SWITCH 1125 15 16 20 1000 LIVING ROOM PLUG 1250 115 16 11 20 1000 LIVING ROOM PLUG Kitchen t , `,t^ '--.Y4}�,� Q PUSHBUTTON CONTROL STATION SURVEILLANCE CAMERA _ l © = 22080 L,�J+ 1h,,;+1 v a� BASE BOARD HEAT 1125 20 2 17 18 1 20 1000 DISPOSAL BASE BOARD HEAT 1250 20 2 117 18 1 20 1000 DISPOSAL Small Appliances 42 EA X 1500 X 35 PC PHOTOELECTRIC CELL 19 20 1000 BATHROOM PLUG 1250 (19 20 11 '20 1000 BATHROOM PLUG Refrigerator 21 EA X 1000 X 75% = 15750 .>„:- ,7r£a 1- DISTRIBUTION EQUIPMENT SYMBOLS _-____ _- 7S TIME SWITCH 0 = 21 22 0 _ 0 21 22 I 0Dishwasher 21 EA X 1000 X 75% = 15750 Q THERMOSTAT AT 60"UNLESS NOTED —`— DISCONNECT SWITCH 23 24 © 0 23 24 I 0 Oven/Range(Re:table220.19) 21 EA X 8000 X 80% = 134400 �0 0 0 25 26 I 0 Disposal 21 EA X 1000 X 75% = 15750 I-'-- e DIVISION 15 EQUIPMENT --ors-- FUSES 0 p 0 27 28 1 0 Microwave 21 EA X 800 X 75% = 12600 Elm... I I FOOD SERVICE EQUIPMENT CIRCUIT BREAKER 0 '0 29 30 l 0 Mechanical EquipmentMO 31 32 0 I.. •I �.J.J CURRENT TRANSFORMER 0 31 32 1 0 Electric Baseboard Heat 725 LF X 250 X 100% = 181250 COMMUNICATION SYSTEM 0 �0 1 133 34 0 Mechanical Equipment TRANSFORMER 0F. 0 35 136 0 Exhaust Fans 44 EA X 20 X 100% = 880 (/') mimi®1 SPEAKER IN CEILING OR WALL 09 METER D 137 38 + 0 38 1- p Add'I 25%Largest Mech.Load 1 LS X 2G' X 25% _ 5 QV I VOLUME CONTROL AT 60"UNLESS NOTED C MAGNETIC MOTOR STARTER 0 139 40 0 0 39 40 1 0 W MICROPHONE OUTLET IN FLOOR BOX OR WALL 0 41 42 —t 0 41 42 ; 0 TOTAL 4275170 2 U DISCONNECT SWITCH I I I s C CALL-IN SWITCH For 208V,3-Phase,4 Wire Service 427517 VA / 361 = 1184 AMPS 1 PANELBOARD OR LOAD CENTER,FLUSH OR SURFACE MOUNTED LOAD CALCULATION SUMMARY OBSERVED ON SITE 2/262016 LOAD CALCULATION SUMMARY OBSERVED ON SITE 2/26/2016 ( ) ® PROGRAM BELL LINEAR FEET OF ELECTRIC BASEBOARD 40 LINEAR FEET OF ELECTRIC BASEBOARD Lamm El INTERCOM f� SWITCHBOARD,MOTOR CONTROL CENTER OR DISTRIBUTION BOARD CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: W El TRANSFORMER 0.93 0.93 Optional Calc per 220.84 Dwelling unit CI (3 CLOCK CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED!OAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS Volt-Amps Demand Total VA Z 0 (i) 11%.""" 117' GROUND P ( I • AMPLIFIER APPLIANCES 0 0 0 0 � APPLIANCES 0 0 0 0 Resto.'bads 38920C 37% 144004 © CIRCUIT BREAKER LIGHTING&RECEPT. 7000 34 4400 21 LIGHTING&RECEPT. 7000 34 4400 21 Electric baseboard loads 181250 37% 67062.5 V ® MOTOR OUTLET MECHANICAL 11000 53 11562.5 56 MECHANICAL 12000 58 12625 61 IATSI AUTOMATIC TRANSFER SWITCH KITCHEN OVEN&DRYER 8000 38 8000 38 KITCHEN OVEN&DRYER 8000 38 8000 38 TOTAL 211067 TOTAL 26000 125 23963 115 TOTAL 27000 130 25025 120 O (o (iuui*)For 208V,3-Phase,4 Wire Service 211067 (VA) / 361 = 585 AMPS 00 ELECTRICAL SPECIFICATIONS Q O a Wa General Requirementsail il..I �.,.. -7, n L / Et I ng 1• SCOPE: Furnish all materials and labor required to execute this work `V/ q 7. REGULATIONS AND CODES: ������ D F�-�3F� CO N.. as indicated on drawing and as specified, as necessary to complete the fD J A. Applicable codes: National Electric Code(2008) 0(�i'� ' contract. Electrical work shall include, but not limited to,these major PP O items: Conform to the prevailing edition and amendments thereto of the Frisco and Summit County Electrical Codes, pertinent NFPA publications Date W A. Complete wiring system for new lighting and power as shown, and to the requirements of Federal, State or other City agencies -. ' _-_`° -., . U including new panelboards, new conduits, new wires, new wiring having jurisdiction. PROVIDE PRICING OPTION TO OWNER TO REPLACE OLDER ITE PANELS B '. iZ devices, new control devices, etc.fora complete lighting and COI �o . p _J , < < — <7 and power system. 8. CONDUIT AND WIRE: a. Complete feeder(s)installation as required for new and/or A. CONDUCTOR SIZES AND TYPES: For sizes#1/0 AWG and larger, use 1711.1 al \ electrical apparatus as shown on single line diagram and copper THIN or aluminum XHHW. For sizes#1 AWG and smaller, use only •ANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL drawings. copper wire with 600V insulation,types TW,THHN, or THW-stranded in 210 208 206 204 202 306 304 302 312 211 402 312 311 310 308 408 406 404 412 411 410 sizes#8 and larger, solid in sizes#10 and smaller. Control wiring shall be#14, z 2. Complete provision, installation and connection of lighting fixtures, stranded. Provide a minimum#8 wire per EC drawings. Ct §. exit signs and lamps as specified and as shown on drawings. © LJ.J 3. Provide grounding and bonding Facilities. 4. Test of entire system and work. H Ilm <10K AICX 2 5. Operating, Maintenance and identification instructions manuals, if TYPICAL L.i...I CO any. (3#2/0 AL, 1 #4 ALG)2"C---A' r' t' r' r' r' r' r' r' r' r' r' r' c. c- r-' r, C' r-- r.' r' 2 6. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- REUSE EXISTING tions, examinations and fees or charges necessary for execution and completion of electrical work. CONTRACTOR TO CONFIRM SERVICE AEC PROJECT#: 16022 GROUNDING IS IN PLACE PER THIS DETAIL DATE: ISSUE: N 02/29/16 PERMIT BONDING JUMPER • G NEW WORK IS CLOUDED (#3/0 CU G)3/4"C r.> REST IS EXIS G #6 TO TELEPHONE/TV — — — — — — �� — — — — — — — — — — — — — — — CONCRETE- ENCASED O( 125/2 O( 125/2 O( 125/2 O( 125/2 O 125/2 O( 125/2 O( 125/2 O C 125/2 O( 125/2 O C 125/2 O C 125/2 Q( 125/2 O( 125/2 O( 125/2 O 125/2 Q( 125/2 Q( 125/2 O C 125/2 O( 125/2 ©( 125/2 O C 125/2 ELECTRODE 55000 AIC :/00 Al I / 1 Drawn By: Checked By: • X2[(4#500 MCM AL) ,,�j I <10K AIC - 411 ' 1 SOH AEC INCOMING GAS SERVICE PIPE r • REUSE EXISTING (3)600A T FUSES 600/3 ri T INCOMING WATER SERVICE — • r UTILITY ELECTRICAL PIPE PAD MOUNTED p EQUIPMENT WATER METER 600A, 2O/2OHV, 3P, 4W 22kAIC & PANEL BUILDING STEEL (3)3/4"x10'DRIVEN CONFIRM UNIT SERVICE AT THESE � `GROUND RODS IF UNITS. REVIEW WITH ENGINEER IF S CHEDULF, THE SERVICE IS NOT 3:2/0 REQUIRED BY LOCAL AHJ v 7-. ELECTRICAL ONE-LINE DIAGRAM , „., NO SCALE SERVICEGROUNDING D ETA I L NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET FAULT CURRENT LEVELS NOTED ON ONE-LINE AS"X AFC",WHERE X IS IN AMPS. SERIES RATED CIRCUIT i NO SCALE BREAKER COMBINATIONS ACCEPTABLE; SUBMIT MANUFACTURER'S SERIES 1 • 0 '�` NOTE: PROVIDE#3/0 CU CONDUCTORS TO ALL GROUNDING ELECTRODES. RATINGS WITH SHOP DRAWING REVIEW. 1 of 1 � _O COPYRIGHT 2014 ARCHITECTURAL ENGINEERING CONSULTANTS,LNG- °:, \- a �i