Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B16-0248 expired plans.pdf
location mapr . A ��a� C* o, C� !awl± of �/aIR ES. EV,/ E.V1WED FOR. d 0r ustrIa 7laus ERCE - PLIANCE T T `�`� rim\ 0. 401494 ;; ae:_77::- _ T�-� '�r-- • Bar & Pantry Renovation {�� ,`,w �3y, _____SSD ARG 242 E. Meadow Drive ; � � _ _. . Vail, CO clra w ine index project notes tkatitria MAO GE\ERAS NOTES: Architectura I Town of il „, 1. ALL WORK TO CONFORM WITH 2015 VERSION OF THE IBC, IFC, IECC & IPCBF; THE 2012 VERSION OF THE IPC & IFGC; A0.0 Cover Sheet s4_ a AND THE 2014 NEC AS ADOPTED AND AMENDED BY THE T.O.V. MUNICIPAL CODE. AIS Floor Plan - ExlatinCE C3P e°;, „ 2. ALL EXISTING WALLS AND FINISHES TO REMAIN AS NOTED - PATCH AND REPAIR IMPACTED FINISHES TO MATCH EXISTING AI.1 Reflected Ceiling Plan - Existing and Demolition ,,.���� �' ADJACENT FINISHES. 3. MAINTAIN THE INTEGRITY OF ALL EXISTING FIRE RESISTIVE WALL AND FLOOR/CEILING ASSEMBLIES - BASED ON ORIGINAL A2.0 Floor Plan - New CONSTRUCTION DOCUMENTS, UNDER THE 1991 UBC, THE EXISTING BUILDING WAS CONSTRUCTED AS A "TYPE II, 1 HOUR" 42.1 FleFiPlan - New ' • - CONSTRUCTION TYPE. THE ENTIRE BUILDING IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. ALL WALLS IN A30 Reffll ecteesh d Ceiling Plan - New THE IMPACTED AREA ARE OF 1-HOUR, NON-COMBUSTIBLE, FIRE RESISTIVE CONSTRUCTION. PER PROJECT DATA LISTED ON A4.0 New Interior Elevations - Pantry: North 4 East ORIGINAL CONSTRUCTION DOCUMENTS, THE FLOOR/CEILING ASSEMBLY FOR THE LEVEL 1 FLOOR SPECIFIES U.L. ASSEMBLY A4.1 New Interior Elevations - Pantry: South 4 West �' TS NO. D858, 2-HOUR RATING. PER THE 2012 IBC, TABLE 508.4, THE FLOOR/CEILING ASSEMBLY IS TO PROVIDE A 1-HOUR .442 New Interior Elevations - Bar: North 4 East c.• \ • I • • .443 New Interior Elevations - Seating Area: East SEPARATION OF THE PARKING GARAGE OCCUPANCY IS2) FROM RESIDENTIAL OCCUPANCIES IR) OR COMMON AREA A4.4 New Interior Elevations - Bar front: East OCCUPANCIES (B). ASSEMBLY (Al OCCUPANCIES ARE NOT REQUIRED TO BE SEPARATED FROM STORAGE OCCUPANCY Typical Bar Section (S). FOR THIS PROJECT, ASSUME A 2-HOUR SEPARATION (2-HOUR FLOOR/CEILING ASSEMBLY) AT THE FLOOR OF THE I� ing PANTRY AND BAR AREA. ALL PENETRATIONS THROUGH THE FLOOR ARE TO BE PROTECTED WITH AH 2-HOUR FIRE Mechanical I�j lu �.J RESISTIVE RATED PENETRATION ASSEMBLY. !(‘LN41! c 1 M-1 HVAC Schedules project team M-2 Garage Plans M-3 Pantry and Bar Plan Owner: Architect: 1E3uildine Department: The Austria 1-laus Club 4 1-lotel Pierce + Frye Architects Town of Vail 242 E. Meadow Drive 30 W. Benchmark Rd., Suite 2I6E lectr I ca l ist) Vail, CO 81657 Avon, CO 81620 -15 South Frontage Road • Contact: Laura Warren ph: 910-949-0899, Ext. 3 Vail, CO 81651 Email: LWarreneAustria -ausClub.com Contact: Tom Frye E-10 Legend, Abbreviations and Symbol List Email: TFrye9PierceFrye.com E-l.l Single Line Diagram 'S E-12 Panel Schedules and Lighting Fixture Schedule Electrical E-20 Power Plan - Main Level„ echanicaIn Engineer: n Ineer: Contractor: E-2.1 Power Plan - Garage Le vel x Rader Erie ineerin9 Wilder En ineering LLC XXX E_3.0 Lighting Plan E 40690 Highway 6, Suite E-1 1110 Blue Sage Drive Ph: XXX E 40 Specifications - Part I • PO Box 8610 Steamboat Springs, CO 81620 Contact: XXX Avon, CO 81620 ph: 910-819- f848 E-4.1 Specifications - Part 2 nt ph: 910-845-1910 Contact: Andrew UJ Ider Email: XXX Contact: Jeff 1-lerschel Email: AndyeWilder-Eng.com 0 `r, Email: Jeff1-161RaderEngineering.com 0v Q Reissued:0 Job No: 23398 Sheet No: Austria Haus 2 Pantry 4 Bar Remodel Drawn By:STAFF PIERCE 242 E. Meadow Dr., Vail, CO 81651 AO.0 + FR Issue03-10-16 Date: 30 W.Benchmark Rd,Ste.216 Tel:970.949.0899 ' PO Box 2320,Avon,CO 81620 Scale: NONE M PATIO - - - - - - -I I © I tF Ca 1 L - - �--I 4� O /iff -� - ,. meq' �11� O . 7.----7 N. (----1 117Y° 1 < o. 401494 v J4�,� r��� _ow ° of Vail O I so/ D A '' w;ll�i IANC FOR CODE ooRRlooR ® �61a y?aft: _ L, j� 1105 I• 1 --- —=-7I . In-ATio.ni= 7 II I -�-� `, LIE OF WORK O I1 lio ID s�" i �I '!I MIMI II m I 7 I1.i ,tom�.... 1 a: II 0 j�` mil"�- I I II ©°° 103 SEATING AREA Town of Vail I 0 o � I, � liifi�ll �_ � I I I i�\,iiULiI� O BE�OW 1 ����m �" 3OFFICE 1 I 11■■11, 25N" REFLECTED CEILING PLA\ GE\ ERAL \OTES: I l` - 1. VERIFY ALL EXISTING CONDITIONS PRIOR TO ANY DEMOLITION NOTIFY OWNER OF ANY CONDITIONS THAT DO NOT MATCH ® -!, I= • . i t� M-f1- -- ♦♦ ♦♦ PLANS. k",••"••' I� . ii2. PLANS ARE FOR GENERAL DEMOLITION INFORMATION - REFER TO ELECTRICAL PLANS FOR ALL SPECIFIC POWER AND �!. • •..► LIGHTING INFORMATION. CO I iiQ „f. I ��-r•�: :• DEVOLITIO\ \OTES: O — I d�P�►`�►•i�i I ' 1. EXISTING WALL TO REMAIN 13, REMOVE EXISTING DOOR, FRAME, CASINGS AND �v�.�4►�15” 2. EXISTING WINDOW TO REMAIN DRYWALL/FRAMING AS REQUIRED TO RELOCATE DOOR rSij, ti `►ri I EX, SERVICE 3. EXISTING CARPET TO REMAIN OPENING PER NEW PLAN. 034/1 �� I Iffinllik -4 � �j TABLE 4. EXISTING QUARRY TILE FLOOR TO REMAIN 14. REMOVE EXISTING S.S. SHELVING. � TT MEM _ -ri 5. EXISTING FLOOR SINK TO REMAIN 15, REMOVE EXISTING BACK-BAR TOP AND ASSOCIATED 6. EXISTING FLOOR DRAIN TO REMAIN SUPPORTS. .4. I 1-4ISFRVINGAREA 7. EXISTING DOOR TO REMAIN REMOVE CASING ON PANTRY 16. REMOVE EXISTING BAR TOP, BAR FRONT, COLUMNS, UPPER 0 �� �..�a -0 •��N,. i SIDE ONLY CABINETS AND CROWN MOLDING EXISTING WALL -_ ���►•••�:!►� 8. EXISTING EQUIPMENT TO REMAIN FRAMING, ELEC. AND PLUMBING TO REMAIN. I N IIIII I �� �•-•-•-,�•-4 9. EXISTING TILE WAINSCOT TO REMAIN 17. REMOVE EXISTING FINISHES, DRYWALL, WALL FRAMING AND _� I Ii �� ► ► M! 10. REMOVE EXISTING EQUIP. ELEC. AS REQUIRED. © M � m,. 11. REMOVE EXISTING EQUIIP. AND REINSTALL AS SHOWN ON 18, RELOCATE EXISTING WATER TREATMENT EQUIPMENT TO - - - NEW PLAN GARAGE BELOW. OI4 12. EXISTING ELECTRIC BREAKER PANEL VERIFY CAPACITY, 19. REMOVE EXISTING CARPET AS REQ'D. LEAVE CLEAN EDGE = Q 0 RECONFIGURE CIRCUITRY AS REQUIRED AND AS NOTED ON AND 4" EXTRA FOR REINSTALL OF CARPET. ELECTRICAL PLANS I I hAL � -, E W 100 LOBBY j r — FN I III x z Rei9e�ued: Job No: 23405 Sheet No: L — Al �` - Austria .4aus \ I I Pantr Bar Remodel Drawn By: TeP Pantry FLOOR PLAN - EXISTINGDEMOLITION PLAN a PIER 242 E. Meadow Dr., Vail, CO 81651 Idque j py + FR Date: 03-10-16 I �� 30 W.Benchmark Rd,Ste.216 Tel:970.949.0899 ���lll 1/4" = 1'-0" moni Avon,CO 81620 Ocala: 1/4" = 1'-0" 0 2' 4' 8' I. Town of Vali of C• O - - - ,,yo-}- I ---' .:'VM E WED FOR CO COOT; ��'�� X90 1 L - -�1�_-I-�, )ate:.:.a_ ''1 I -�� - ir 4 ERCE ir � G�TS r� ' • o. 401494 1 ii FLOOR PLAN GE \ERAL NOTES: Q. 1 1. THERE IS NO CHANGE IN USE OR OCCUPANCY AND SCOPE OF WORK IS LIMITED TO THE BAR AND PANTRY AREAS. i. EXISTING SEATING AREA TO REMAIN. PROTECT, PATCH, REPAIR AND CLEAN EXISTING AREAS-TO-REMAIN AS NEEDED. 7.---- 0 0 c, ,�' 2. VERIFY ALL EXISTING CONDITIONS PRIOR TO ANY DEMOLITION - NOTIFY OWNER OF ANY CONDITIONS THAT DO NOT ® I MATCH PLANS. 105 CORRIDOR 1 3. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR ALL SPECIFIC INFORMATION REGARDING HVAC, PLUMBING r--LIT OF WORK REQUIREMENTS ELECTRICAL CONNECTION AND CIRCUITRY AND LIGHTING. 'Town of Vail ij ''' -, I 103 SEATINGAREA® g j • EXISTING NOAREADADA COVPLA` CE \OTES: OFFIC P�� 9 1. PER SECTION 1108.2.9.1 OF THE 2015 IBC, 5% OF THE DINING SURFACES FOR CONSUMPTION OF FOOD AND DRINK SEATING AND DINING 102 BARS-� SHALL BE ACCESSIBLE. EXISTING ADJACENT SEATING IS NON-FIXED AND ACCESSIBLE. BAR DOES NOT HAVE A = \ • L_...7-1i O I •I r SURFACES TO REMAIN LOWER SEATING SECTION AS ACCESSIBLE SEATING IS PROVIDED IN EXISTING ADJACENT DINING AREA. ( y 1) LI • d: FLOOR PLA\ NOTES: ® IoN.Li ©v, ..� I. REFER TO SHT. A2.1 FOR FLOOR FINISHES. 17. RELOCATED, EXISTING 2-DOOR COOLER BELOW. Tel ® �j� 0 �sT To , 2. EXISTING FLOOR STINK TO REMAIN, 18. RELOCATED, EXISTING ICE MAKER. Ili ® C 3. EXISTING FLOOR DRAIN TO REMAIN. 19. NEW STONE BAR TOP WITH DRINK RAIL - SEE 2-A4.4 4. EXISTING HAND SINK TO REMAIN. 20. NEW STONE BACK BAR TOP W/ VERTICAL © __ '' _ g" I r 5. EXISTING DUMP SINK TO REMAIN. DIVIDERS/SUPPORTS AS SHOWN ON 2-A4.2 - MATCH BAR ® 144" 32" T 151" X30" 60" 6. EXISTING S.S. WORK TABLE TO REMAIN ADD SHELVING TOP EDGE DETAIL AND HEIGHT. p:i i / I��t� BELOW. 21. NEW LIQUOR CABINETS W/ REMOVABLE, LOCKABLE41 'i=il Li w I I 7. EXISTING WORK TABLE AND PREP SINK TO REMAIN, GLASS DOORS - SEE 2-A4.2 0 �� - I ,�, 8. EXISTING DISHWASHER TO REMAIN. 22. NEW BUFFET/STORAGE CABINET W/ STONE TOP. ® ,=©i I ¢ I 24 9. EXISTING 3 COMPARTMENT SINK TO REMAIN - CUT DOWN RECONFIGURE ELEC. TO ACCOMMODATE SMALL 114$ i / co , EXISTING 30" HIGH 127 "+ • I m ES I SERVICE TABLE SIDE SPLASH ON LEFT SIDE TO ALLOW ACCESS TO APPLIANCES (TOASTER, WARMING PLATES, ETC.( v� COFFEE BREWER AND GRINDER. 23. NEW STONE CONDIMENT SHELF W/ STONE CORBELS. O la r- I w 10. EXISTING POCKET DOOR TO REMAIN - REPLACE EXISTING 24. EXISTING SERVING TABLE TO BE RELOCATED. © Il I L11-w.1, 101 PANTRY i d 1 1' .i z ® CASING W/ 1X3, S4S CASING ON PANTRY SIDE ONLY, 25. EXISTING BAR WALL, PLUMBING AND ELEC. TO REMAIN. ® Vvi i i; 104ISERVINGAREA FINISH TO MATCH EXISITING. 26. NEW WALL MOUNTED COOLING UNIT SEE MECHANICAL orb i L_- r_ .ii ® 11. NEW S.S. WORK TABLE W/ SHELVING BELOW PER PLANS AND DETAILS. 11( -"""'"' ' 3 RESTAURANT EQUIPMENT SUPPLIER SPECS. 27. EXISTING WALL MOUNTED S.S. SHELF AND MICROWAVE twAiik 1111-111.n7.; _Y I, ,, ... !r �� a'AR - - I � :T-j3 " 12. NEW S.S. WORK TABLE W/ TRASH CONTAINERS BELOW TO REMAIN. I �eimL: :: �_' �� AND OVEN ON COUNTER. 28. NEW WALL - MTL. STUD FRAMING AT 16" O.C. WITH %" l���i\ 13. NEW S.S. WALL MOUNTED SHELF PER RESTAURANT W.R., TYPE X GYP. BRD. ON PANTRY SIDE AND %" TYPE EQUIPMENT SUPPLIER SPECS. X GYP. BRD. ON OPP. SIDE. EXISTING14. RELOCATED, REFRIGERATOR. Q 0 Q ® 15. EXIST NG ELECT. BR AKER PANEL - RECONFIGURE 30. GLASS S ELVING MOUNTED, S.S. DRAIN RACK TO REMAIN. ABOVE. I IEXISTING CIRCUITS TO ACCOMMODATE NEW EQUIP. AS 31. NEW POCKET DOOR AND CASING TO MATCH EXISTING - I I REQUIRED. REFER TO ELECTRICAL PLANS AND DETAILS. 1x3, S4S CASING BOTH SIDES, FINISH TO MATCH I I 16. RELOCATED, 120v COFFEE BREWER AND GRINDER. EXISTING DOOR AND CASING. 32, EXISTING ESPRESSO MACHINE AND GRINDER I �� Ejir, ,/D W milL71001LOBBY Austria {-Taus Reissued: Job No: 23405 Sheet No: r Pantry 4 Bar Remodel Drawn By: TE3F I III 1 � 242 E. Meadour pr., Vail, CO 8165 i�OO� ���I` _ � � Issue03-10-16L� ,� 1 Date: 1�30 W.Benchmark Rd,Ste.216Tel:970.949.0899 1/4" = 1'-m" Avon,CO 81620 Scale: 1/4" = 1'-0" 0 2' 4' 83' — - - - 1 — L - - I _ of Co O • -� \ ;.. ERCE I-- o. 401494 I i li ill 105 CORRIDOR', 1 -- r—LIE OF WORK !I. - .ma----1 mr-----: „1 ii 1 © 4 j1 0 103 SEATING AREA : 1 z 1 ' NM c mu 1 1 i:4', tit ' ;-_,,- ((-- ---- : ____ _. 0,,„.410,.....,_44. II 1 y ...-- 1. �lim ', , � � 0 _____= - - _....,•'hi II r — I (a4:7------ . } IIle Town of Vail a } i 1 I p FINISH FLOOR PSA\ \OYES. 1 FFILIE itl • rir 1 / 0. 0 ® -� =LL� " . 1. EXISTING 8x8 QUARRY TILE TO REMAIN, 7. CUT CARPET & PATCH AS REQUIRED. w - i ' I ' PATCH/REPLACE TILE AS NEEDED - REPLACE 8. EXISTING CARPET TO REMAIN - PROTECT DURING ID I I 104 SERVING AREA I EXISTING 6x8 QUARRY TILE BASE AS NEEDED, CONSTRUCTION, iv 2. NEW 8x8 QUARRY TILE FLOORING AND BASE TO 9, EXISTING FLOOR STINK - PIPE ALL NEW AND EXISTING N I- I I MATCH EXISTING. EQUIP. TO FLOOR SINKS AS REQUIRED BY CODE. A Ek L d Fi .f A.... I I 3. EXISTING POCKET DOOR & THRESHOLD TO REMAIN - 10. EXISTING FLOOR DRAIN TO REMAIN. a� J roI� . REFINISH TO MATCH EXISTING J /� Val ==,ate �. - 4. NOT USED O5. EXISTING BAR WALL TO REMAIN. 6. NEW POCKET DOOR TO MATCH EXISTING - m .� REMOVE/REPLACE QUARRY TILE FLOORING AND BASE T I I \ AS NEEDED. \ L EXISTING QUARRY TILE NEW QUARRY TILE ,,_ FLOOR AND COVE BASE FLOOR AND COVE BASE �ci 0 100 LOBBY -- .471•7 Mraf/ " it ii I III it"NN%''''''`......„.... N \l t *I ' I p A I *I III / z 1 Reip9ued: Job No: 23405 Sheet No: z FLOOR rIIVl511'? FLAN— MEW U Austria Maus o w Pant% 4 Bar Remodel Drawn By: TBF .5 Cl.) E3 PIERCE' 242 E. Meaaow Dr., Vail, CO 81651 issue 2 '1 ..., + FRY 03-10-I6 1/4" = 1'-(d" a Date: 30W.Benchmark Rd,Ste.216 Tel:970.949.0899 0 2' 4' 8' .A`""` Avon,CO 81620 Scal1e: 1/4" = 1'-0" -Tovvin of Vail - Toni of Vail REVIEWED FOR CODE . OFFICE CIPY COMPLIANCE • Date:___ 7 - ( Z ' , \TENOR ELEVATION \OTES: w.� 1. .090" F.R.P. SHEETS TO CEILING - PROVIDE END CAPS, DIVISION BARS, INSIDE CORNERS AND DRAWINGS. WALNUT SHELF CLEAT AT EA. SIDE. t/-�` OUTSIDE CORNERS TO COMPLETE THE INSTALLATION OF F.R.P. SHEETS - CAULK WHERE 12. RELOCATED LIGHT SWITCHES/DIMMERS 23. MIRRORED BAR BACK WALL C' ^ P ACCESSORIES MEET DISSIMILAR MATERIALS. INSTALL SHEETS PER MANUFACTURER'S 13. NEW LIGHT SWITCH 24. EXISTING SWITCH TO REMAIN REQUIREMENTS.. 14. NEW MINI-SPLIT AIR CONDITIONING UNIT - LOCATE COMPRESSOR IN GARAGE BELOW. SEE 25. NEW WALNUT, RAISED PANEL, BUFFET CABINET W/ STONE TOP - PROVIDE 5" DRAWERS AT 2. NEW 8x8 QUARRY TILE WAINSCOT - MATCH EXISTING MECHANICAL DRAWINGS TOP AND ADJUSTABLE, ROLL-OUT SHELVES IN CABINET BELOW. INSTALL HEAVY DUTY, FULL 3. NEW 6x8 QUARRY TILE COVE BASE- MATCH EXISTING 15. EXISTING CORNER GUARD TO REMAIN EXTENSION DRAWER SLIDES AT DRAWERS AND SHELVES. DRILL HOLES AND INSTALL 4. NEW 8x8 QUARRY TILE FLOORING - MATCH EXISTING 16. EXISTING WOOD BASE BOARD TO REMAIN GROMMETS FOR SMALL APPLIANCES TO PLUG IN BELOW COUNTER TOP. 5, EXISTING QUARRY TILE WAINSCOT TO REMAIN 17. NEW FORGED STEEL FOOT RAIL - DETAILS TO BE DETERMINED 26. STONE BACK & SIDE SPLASH, TYP, 6. EXISTING POCKET DOOR TO REMAIN - REFINISH DOOR AND PROVIDE NEW 1x3 ALDER CASING 18, NEW STONE BAR TOP W/ PLYWD. SUB-TOP AND WOOD CORBELS TO MATCH PANELED BAR 27. NEW SCONCE - MATCH EXISTING SCONCES. ON PANTRY SIDE OF OPENING. FRONT. 28. NEW ELECTRIC ROUGH-IN FOR KITCHEN EQUIP. PER SPECS. SEE ELEC. DRAWINGS 7. EXISTING DOOR OPENING LOCATION - INFILL WITH METAL STUD FRAMING AND 8", W.R. TYPE 19. NEW STONE BACK BAR TOP W/ PLYWD. SUB-TOP - PROVIDE 1-1/2" WIDE VERTICAL PANELS 29. REMOVE EXISTING COUNTER TOP SUPPORT CLEAT AND PATCH WALL 'X' GYP. BRD. AT EACH SIDE OF 2-DOOR COOLER UNIT FOR COUNTERTOP SUPPORT - COORD, WITH 30. NEW WALNUT CROWN - PROFILE TO MATCH EXISTING- FINISH TO MATCH NEW BAR FRONT 8. NEW DOOR POCKET BEYOND KITCHEN EQUIP. SPECS. PROVIDE GROMMETS IN COUNTER TOP FOR ELECTRICAL AND AND BACK BAR 9. EXISTING ESPRESSO MACHINE AND COFFEE GRINDER PLUMBING CONNECTIONS FOR ESPRESSO MACHINE AND GRINDER. 31. EXISTING QUARRY TILE BASE TO REMAIN 10. NEW POCKET DOOR, FRAME AND CASING. PROVIDE NEW 1x3 ALDER CASING ON PANTRY SIDE 20. NEW WALNUT, RAISED PANEL BAR FRONT - FINISH AND DETAILS TO BE DETERMINED. 32. RECESSED, LED LIGHT IN TOP OF CABINET - SEE ELEC. DRAWINGS OF OPENING. PROVIDE NEW DOOR CASING ON BAR SIDE OF OPENING TO MATCH EXISTING 21. NEW GLASS FRONT, LOCKABLE, WALNUT LIQUOR CABINET WITH RECESSED LIGHTS AT TOP 33. UNDER-CABINET, LED LINEAR LIGHT - SEE ELEC. DRAWINGS. CASING. OF CABINET AND LINEAR STRIP LIGHT AT AT BOTTOM OF CABINET ABOVE BAR BACK TOP. 34. STONE CONDIMENT SHELF AND CORBELS. 11. EXISTING AND NEW ELECT. RECEPTACLES - COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. PROVIDE 2 - 3/8" CLEAR GLASS SHELVES. ELECTRIC CIRCUITS PER MANUFACTURER AND NEC CODE REQUIREMENTS. SEE ELEC. 22. 2 - 3/8" THICK CLEAR GLASS SHELVES FOR GLASSWARE. PROVIDE 1-1/2"x 1-1/2" PROFILED dC C. () a NEW WALL v m +`, co .E. S. ni 10 I A/C UNIT I J ;.. AVE f-- Q ¢ 0. 4� a o - a �� \ 40494 /<v� o MICROWAVE x . i - -- - - ---=-== =- - _ - 410 ig - 1 m 1)S 7- , r o - �-r -n C LCI-----IL I n_ ` nJ IFS Ty r -17 aO I I I I I I I 4 LL_ II II 11 I 1I I I III I I I I I I 1 I I m I I 1 I I I III I I I I I I 11 I I I '? II Iia rr 0 I Bp �a H < II 1 I I I DISHWASHER I I 11 II i I I I I I ! II a ,© I I I 1 1 I I II 8 1 I �i O 0 1 I I I I I II 5 �O ! i , 1 Iii , I , , 11 6 7 NEW INTER ELEV. - PANTRY - NORTH NEW INTER. ELEV. - PANTRY - EAST QI • • al 1/211 11-011 1/21 _ I -0II Austria Haus Reissued: Job No: 23405 sheet No: • Q - I-2' • Pantry 4 Bar Remodel Drawn By: TSF ._ NOTE: PIERCO 242 .Meaoow Dr., Vail, CO 81657 PANTRY AND BAR EQUIPMENT NOT SHOWN FOR CLARITY. FRYE Issue 03-10-I6 �� 30 W.Benchmark Rd,Ste.216 Tel:970.949.0899 EQUIPMENT PROVIDED AND NSTALLED BY OTHERS " Avon,CO 81620 Scale: 1/211 = 11-011 Town of Vail Town Of Vail , a ri - el._. _ .. ____, a FUIEWEl� F©R CO F'l._lANnE E • INTERIOR ELEVATIO\ \OTES: By: _ p� 1. .090" F.R.P. SHEETS TO CEILING - PROVIDE END CAPS, DIVISION BARS, INSIDE CORNERS AND DRAWINGS. WALNUT SHELF CLEAT AT EA. SIDE. --- OUTSIDE CORNERS TO COMPLETE THE INSTALLATION OF F.R.P. SHEETS CAULK WHERE 12. RELOCATED LIGHT SWITCHES/DIMMERS 23, MIRRORED BAR BACK WALL .1�j II�,, b ACCESSORIES MEET DISSIMILAR MATERIALS. INSTALL SHEETS PER MANUFACTURER'S 13. NEW LIGHT SWITCH 24. EXISTING SWITCH TO REMAIN REQUIREMENTS.. 14. NEW MINI-SPLIT AIR CONDITIONING UNIT - LOCATE COMPRESSOR IN GARAGE BELOW. SEE 25. NEW WALNUT, RAISED PANEL, BUFFET CABINET W/ STONE TOP - PROVIDE 5" DRAWERS AT 2. NEW 8x8 QUARRY TILE WAINSCOT - MATCH EXISTING MECHANICAL DRAWINGS TOP AND ADJUSTABLE, ROLL-OUT SHELVES IN CABINET BELOW. INSTALL HEAVY DUTY, FULL 3. NEW 6x8 QUARRY TILE COVE BASE- MATCH EXISTING 15, EXISTING CORNER GUARD TO REMAIN EXTENSION DRAWER SLIDES AT DRAWERS AND SHELVES. DRILL HOLES AND INSTALL 4. NEW 8x8 QUARRY TILE FLOORING - MATCH EXISTING 16. EXISTING WOOD BASE BOARD TO REMAIN GROMMETS FOR SMALL APPLIANCES TO PLUG IN BELOW COUNTER TOP. 5. EXISTING QUARRY TILE WAINSCOT TO REMAIN 17. NEW FORGED STEEL FOOT RAIL - DETAILS TO BE DETERMINED 26. STONE BACK & SIDE SPLASH, TYP. 6. EXISTING POCKET DOOR TO REMAIN - REFINISH DOOR AND PROVIDE NEW 1x3 ALDER CASING 18. NEW STONE BAR TOP W/ PLYWD. SUB-TOP AND WOOD CORBELS TO MATCH PANELED BAR 27. NEW SCONCE - MATCH EXISTING SCONCES. ON PANTRY SIDE OF OPENING. FRONT. 28. NEW ELECTRIC ROUGH-IN FOR KITCHEN EQUIP. PER SPECS. SEE ELEC. DRAWINGS 7. EXISTING DOOR OPENING LOCATION - INFILL WITH METAL STUD FRAMING AND I", W.R. TYPE 19. NEW STONE BACK BAR TOP W/ PLYWD. SUB-TOP - PROVIDE 1-1/2" WIDE VERTICAL PANELS 29. REMOVE EXISTING COUNTER TOP SUPPORT CLEAT AND PATCH WALL 'X' GYP. BRD. AT EACH SIDE OF 2-DOOR COOLER UNIT FOR COUNTERTOP SUPPORT - COORD. WITH 30. NEW WALNUT CROWN - PROFILE TO MATCH EXISTING- FINISH TO MATCH NEW BAR FRONT 8. NEW DOOR POCKET BEYOND KITCHEN EQUIP. SPECS. PROVIDE GROMMETS IN COUNTER TOP FOR ELECTRICAL AND AND BACK BAR 9, EXISTING ESPRESSO MACHINE AND COFFEE GRINDER PLUMBING CONNECTIONS FOR ESPRESSO MACHINE AND GRINDER. 31. EXISTING QUARRY TILE BASE TO REMAIN 10. NEW POCKET DOOR, FRAME AND CASING. PROVIDE NEW 1x3 ALDER CASING ON PANTRY SIDE 20. NEW WALNUT, RAISED PANEL BAR FRONT - FINISH AND DETAILS TO BE DETERMINED. 32. RECESSED, LED LIGHT IN TOP OF CABINET - SEE ELEC. DRAWINGS OF OPENING. PROVIDE NEW DOOR CASING ON BAR SIDE OF OPENING TO MATCH EXISTING 21. NEW GLASS FRONT, LOCKABLE, WALNUT LIQUOR CABINET WITH RECESSED LIGHTS AT TOP 33. UNDER-CABINET, LED LINEAR LIGHT - SEE ELEC. DRAWINGS. CASING. OF CABINET AND LINEAR STRIP LIGHT AT AT BOTTOM OF CABINET ABOVE BAR BACK TOP. 34. STONE CONDIMENT SHELF AND CORBELS, 11. EXISTING AND NEW ELECT. RECEPTACLES - COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. PROVIDE 2 - 3/8" CLEAR GLASS SHELVES. J,,,,,s .ELECTRIC CIRCUITS PER MANUFACTURER AND NEC CODE REQUIREMENTS. SEE ELEC. 22. 2 - 3/8" THICK CLEAR GLASS SHELVES FOR GLASSWARE. PROVIDE 1-1/2"x 1-1/2" PROFILED Ii NEW WALL AIII, NEW WALL (- OD .Irg" - 7 I - ,7. 1t �r - r 1 0 `1_ h 1 L k1 U w 1 1 r • a ° IN I 0 OVEN o c I I I REFRIGERATOR � I 11 I 1 I t I I I © __ 0 1 I I 1 1 28 f1 II NI 1 I I O 0 ' 1- I I I I - __ I I I Il 0 ta NEW INTER ELEV. - PANTRY - SOUTH NEW INTER ELEV. - PANTRY - WEST (-1) • _▪ � 1/2" = 1'-0" 1/2" = 1' N Austria Haus Reissued: Job No: 23405 Sheet No: w - o Pantry 4 Bar Remodel Drawn By: TBF • 4/ 1 - %NOTE; 0 1' 2' 4' PIERC 242 E Meadow Dr., Vail, CO 81651 Issue PANTRY AND BAR EQUIPMENT NOT SHOWN FOR CLARITY. + FRY. 30 W.Benchmark Rd,Ste.216 Tel:970.949.0899 Date_ 03-10-lb EQUIPMENT PROVIDED AND NSTALLED BY OTHERS "`4`°" Avon,CO81620 Scale: I/2" = 1'-0" 'Town of Valli Town of /ail 0 )•'.'F'4 . ':= EVIEED F®R ��D 1-'' IV ipy \TERIOR ELEVATIO\ \OTES: . • 1; .090" F.R.P. SHEETS TO CEILING - PROVIDE END CAPS, DIVISION BARS, INSIDE CORNERS AND DRAWINGS. WALNUT SHELF CLEAT AT EA. SIDE. )ate: - _, _-_-- E OUTSIDE CORNERS TO COMPLETE THE INSTALLATION OF F.R.P. SHEETS - CAULK WHERE 12. RELOCATED LIGHT SWITCHES/DIMMERS 23. MIRRORED BAR BACK WALL C)' -- ACCESSORIES MEET DISSIMILAR MATERIALS. INSTALL SHEETS PER MANUFACTURER'S 13. NEW LIGHT SWITCH 24. EXISTING SWITCH TO REMAIN REQUIREMENTS.. 14. NEW MINI-SPLIT AIR CONDITIONING UNIT - LOCATE COMPRESSOR IN GARAGE BELOW. SEE 25. NEW WALNUT, RAISED PANEL, BUFFET CABINET W/ STONE TOP - PROVIDE 5" DR)A' ERS AY-- 2. NEW 8x8 QUARRY TILE WAINSCOT - MATCH EXISTING MECHANICAL DRAWINGS TOP AND ADJUSTABLE, ROLL-OUT SHELVES IN CABINET BELOW. INSTALL HEAVY DUTY, FULL 3. NEW 6x8 QUARRY TILE COVE BASE- MATCH EXISTING 15. EXISTING CORNER GUARD TO REMAIN EXTENSION DRAWER SLIDES AT DRAWERS AND SHELVES. DRILL HOLES AND INSTALL 4. NEW 8x8 QUARRY TILE FLOORING - MATCH EXISTING 16. EXISTING WOOD BASE BOARD TO REMAIN GROMMETS FOR SMALL APPLIANCES TO PLUG IN BELOW COUNTER TOP. 5. EXISTING QUARRY TILE WAINSCOT TO REMAIN 17. NEW FORGED STEEL FOOT RAIL - DETAILS TO BE DETERMINED 26. STONE BACK & SIDE SPLASH, TYP. 6. EXISTING POCKET DOOR TO REMAIN - REFINISH DOOR AND PROVIDE NEW 1x3 ALDER CASING 18. NEW STONE BAR TOP W/ PLYWD. SUB-TOP AND WOOD CORBELS TO MATCH PANELED BAR 27. NEW SCONCE - MATCH EXISTING SCONCES. ON PANTRY SIDE OF OPENING. FRONT. 28. NEW ELECTRIC ROUGH-IN FOR KITCHEN EQUIP. PER SPECS. SEE ELEC. DRAWINGS 7. EXISTING DOOR OPENING LOCATION - INFILL WITH METAL STUD FRAMING AND g", W.R. TYPE 19. NEW STONE BACK BAR TOP W/ PLYWD. SUB-TOP - PROVIDE 1-1/2" WIDE VERTICAL PANELS 29. REMOVE EXISTING COUNTER TOP SUPPORT CLEAT AND PATCH WALL 'X' GYP. BRD. AT EACH SIDE OF 2-DOOR COOLER UNIT FOR COUNTERTOP SUPPORT - COORD. WITH 30. NEW WALNUT CROWN - PROFILE TO MATCH EXISTING- FINISH TO MATCH NEW BAR FRONT 8. NEW DOOR POCKET BEYOND KITCHEN EQUIP. SPECS. PROVIDE GROMMETS IN COUNTER TOP FOR ELECTRICAL AND AND BACK BAR 9. EXISTING ESPRESSO MACHINE AND COFFEE GRINDER PLUMBING CONNECTIONS FOR ESPRESSO MACHINE AND GRINDER. 31. EXISTING QUARRY TILE BASE TO REMAIN 10. NEW POCKET DOOR, FRAME AND CASING. PROVIDE NEW 1x3 ALDER CASING ON PANTRY SIDE 20. NEW WALNUT, RAISED PANEL BAR FRONT - FINISH AND DETAILS TO BE DETERMINED. 32. RECESSED, LED LIGHT IN TOP OF CABINET - SEE ELEC. DRAWINGS `` CSF Qopi OF OPENING. PROVIDE NEW DOOR CASING ON BAR SIDE OF OPENING TO MATCH EXISTING 21. NEW GLASS FRONT, LOCKABLE, WALNUT LIQUOR CABINET WITH RECESSED LIGHTS AT TOP 33. UNDER-CABINET, LED LINEAR LIGHT - SEE ELEC. DRAWINGS. �v CASING. OF CABINET AND LINEAR STRIP LIGHT AT AT BOTTOM OF CABINET ABOVE BAR BACK TOP. 34. STONE CONDIMENT SHELF AND CORBELS. 1�� Qv ii. EXISTING AND NEW ELECT. RECEPTACLES - COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. PROVIDE 2 - 3/8" CLEAR GLASS SHELVES. ; 1 `r 'E S. ELECTRIC CIRCUITS PER MANUFACTURER AND NEC CODE REQUIREMENTS. SEE ELEC. 22. 2 - 3/8" THICK CLEAR GLASS SHELVES FOR GLASSWARE. PROVIDE 1-1/2"x 1-1/2" PROFILED 4( 4 ERCE •SIM 0 ® ® r� o. 401494 NEW WALL ® 24 n 52" 24" ® 0a. t ' N I� \ i/ II ® .---_____ II L. • _- -___ L Q 7 - I CAB. O ■/iiiiiiii.i / � m eE x _ NIJEI I I I c+0e t El IN) (El I I c ----z� I Imo- I L _i ISI ��' g _�I (1 I ® _ I [1 I- - - - 17 :-'.'S r - - 11 r 0 11 I i BACK BAR m ICE MACHINE 2 DOOR COOLER I I e H I I I I s K II I r 0 I ! .H I II . L sz . GI 28 " VERIFY 62" VERIFY ,l' R 0 NEW INTER. ELEV - 8AR - NOT NEW INTER, ELEY_ - E3AR - EAST 1/2" = II-(d" f Reissued: Job No: 23405 Sheet No: Austria Naus z• �� ,Pantry 4 Bar Remodel Drawn By: TIS 4.2 NOTE; m 1' 2' P1ERc 242 E.Meadow Dr., Vail, CO 81651 Issue+ FRY Date: 03-10-I6 PANTRY AND BAR EQUIPMENT NOT SHOWN FOR CLARITY. 30 W.BenchmilrkRd,Ste.216 Tel:970.949.01199 EQUIPMENT PROVIDED AND NSTALLED BY OTHERS `"`"""' Avon,CO81620 {kale: 1/2" = 1'-0° Town of Vail 'Town of Vali ��® � V�EE�D � OFFICE,. COPY 1 /� . . INTERIOR ELEVATIO\ \OTES: ae: / 1. .090" F.R.P. SHEETS TO CEILING - PROVIDE END CAPS, DIVISION BARS, INSIDE CORNERS AND DRAWINGS. WALNUT SHELF CLEAT AT EA. SIDE. `�i° JS/ OUTSIDE CORNERS TO COMPLETE THE INSTALLATION OF F.R.P. SHEETS - CAULK WHERE 12. RELOCATED LIGHT SWITCHES/DIMMERS 23. MIRRORED BAR BACK WALL -� ' 7 ACCESSORIES MEET DISSIMILAR MATERIALS. INSTALL SHEETS PER MANUFACTURER'S 13. NEW LIGHT SWITCH 24. EXISTING SWITCH TO REMAIN �'`���r REQUIREMENTS.. 14. NEW MINI-SPLIT AIR CONDITIONING UNIT - LOCATE COMPRESSOR IN GARAGE BELOW. SEE 25. NEW WALNUT, RAISED PANEL, BUFFET CABINET W/ STONE TOP PROVIDE 5" DRAWERS AT 2. NEW 8x8 QUARRY TILE WAINSCOT - MATCH EXISTING MECHANICAL DRAWINGS TOP AND ADJUSTABLE, ROLL-OUT SHELVES IN CABINET BELOW. INSTALL HEAVY DUTY, FULL 3. NEW 6x8 QUARRY TILE COVE BASE- MATCH EXISTING 15. EXISTING CORNER GUARD TO REMAIN EXTENSION DRAWER SLIDES AT DRAWERS AND SHELVES. DRILL HOLES AND INSTALL 4. NEW 8x8 QUARRY TILE FLOORING - MATCH EXISTING 16. EXISTING WOOD BASE BOARD TO REMAIN GROMMETS FOR SMALL APPLIANCES TO PLUG IN BELOW COUNTER TOP. 5. EXISTING QUARRY TILE WAINSCOT TO REMAIN 17. NEW FORGED STEEL FOOT RAIL - DETAILS TO BE DETERMINED 26. STONE BACK & SIDE SPLASH, TYP. 6. EXISTING POCKET DOOR TO REMAIN - REFINISH DOOR AND PROVIDE NEW 1x3 ALDER CASING 18. NEW STONE BAR TOP W/ PLYWD. SUB-TOP AND WOOD CORBELS TO MATCH PANELED BAR 27. NEW SCONCE - MATCH EXISTING SCONCES. ON PANTRY SIDE OF OPENING. FRONT. 28. NEW ELECTRIC ROUGH-IN FOR KITCHEN EQUIP. PER SPECS. SEE ELEC. DRAWINGS 7. EXISTING DOOR OPENING LOCATION - INFILL WITH METAL STUD FRAMING AND g", W.R. TYPE 19, NEW STONE BACK BAR TOP W/ PLYWD. SUB-TOP - PROVIDE 1-1/2" WIDE VERTICAL PANELS 29. REMOVE EXISTING COUNTER TOP SUPPORT CLEAT AND PATCH WALL 'X' GYP. BRD. AT EACH SIDE OF 2-DOOR COOLER UNIT FOR COUNTERTOP SUPPORT - COORD. WITH 30. NEW WALNUT CROWN - PROFILE TO MATCH EXISTING- FINISH TO MATCH NEW BAR FRONT 8. NEW DOOR POCKET BEYOND KITCHEN EQUIP. SPECS. PROVIDE GROMMETS IN COUNTER TOP FOR ELECTRICAL AND AND BACK BAR ��OF C 9. EXISTING ESPRESSO MACHINE AND COFFEE GRINDER PLUMBING CONNECTIONS FOR ESPRESSO MACHINE AND GRINDER. 31. EXISTING QUARRY TILE BASE TO REMAIN 10. NEW POCKET DOOR, FRAME AND CASING. PROVIDE NEW 1x3 ALDER CASING ON PANTRY SIDE 20. NEW WALNUT, RAISED PANEL BAR FRONT - FINISH AND DETAILS TO BE DETERMINED, 32. RECESSED, LED LIGHT IN TOP OF CABINET - SEE ELEC. DRAWINGS •`T OF OPENING. PROVIDE NEW DOOR CASING ON BAR SIDE OF OPENING TO MATCH EXISTING 21. NEW GLASS FRONT, LOCKABLE, WALNUT LIQUOR CABINET WITH RECESSED LIGHTS AT TOP 33. UNDER-CABINET, LED LINEAR LIGHT - SEE ELEC. DRAWINGS. �� `�T Q CASING. OF CABINET AND LINEAR STRIP LIGHT AT AT BOTTOM OF CABINET ABOVE BAR BACK TOP. 34. STONE CONDIMENT SHELF AND CORBELS. 'k ••'E S. 0 11. EXISTING AND NEW ELECT. RECEPTACLES - COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. PROVIDE 2 - 3/8" CLEAR GLASS SHELVES. * ' ERCE ELECTRIC CIRCUITS PER MANUFACTURER AND NEC CODE REQUIREMENTS. SEE ELEC. 22. 2 - 3/8" THICK CLEAR GLASS SHELVES FOR GLASSWARE. PROVIDE 1-1/2"x 1-1/2" PROFILED a '' '' ( ) r; 0. 401494 U 1. c, /, ......„2":1 . i N t n n . O oz o A 0 m N '� / m U CO ao S - - - _ r C Niumiti 415 COill 0 n O O O O O 0 x 25 . u T d;- d 3 N _N i -7- / \ / / \ / \ / \ / / O i 1 _ / \�-_ / _ - -- - 1r ` --7 ' \-, / \ / 1 m ro NEW INTER, ELEV. SEATING ING AREA AST Reissued: 5 sheet No: w 0 Job No: 2340 1/2" = 1'-0" Austria Haus _ Pantry 4 Bar Remodel Drawn By: TBF - -- NOTE: 242 E.Meadow Dr., vail, CO 81651 Ippue 4/ 3 ' PANTRY AND BAR EQUIPMENT NOT SHOWN FOR CLARITY. 0 1 2 4' 30W Benchmark Rd,Ste 216 Tel:970.949.0899 ,Date: 03-10-I6 I EQUIPMENT PROVIDED AND NSTALLED BY OTHERS Avon��o8�6�b 1 scale: I!2" = I'-0" Town of oFFicE Vail Town; cif Vail p VdEWE FOR COMP ; ' ;'' .,.-,E INTERIOR ELEVATION \OTES: _ � � � L /G Date:._ 1. .090" F.R.P. SHEETS TO CEILING - PROVIDE END CAPS, DIVISION BARS, INSIDE CORNERS AND DRAWINGS. WALNUT SHELF CLEAT AT EA. SIDE. By. .. . / OUTSIDE CORNERS TO COMPLETE THE INSTALLATION OF F.R.P. SHEETS - CAULK WHERE 12. RELOCATED LIGHT SWITCHES/DIMMERS 23. MIRRORED BAR BACK WALL ^�- / S- ACCESSORIES MEET DISSIMILAR MATERIALS. INSTALL SHEETS PER MANUFACTURER'S 13. NEW LIGHT SWITCH 24. EXISTING SWITCH TO REMAIN REQUIREMENTS.. 14. NEW MINI-SPLIT AIR CONDITIONING UNIT - LOCATE COMPRESSOR IN GARAGE BELOW. SEE 25. NEW WALNUT, RAISED PANEL, BUFFET CABINET W/ STONE TOP - PROVIDE 5" DRAWERS AT 2. NEW 8x8 QUARRY TILE WAINSCOT - MATCH EXISTING MECHANICAL DRAWINGS TOP AND ADJUSTABLE, ROLL-OUT SHELVES IN CABINET BELOW. INSTALL HEAVY DUTY, FULL 3. NEW 6x8 QUARRY TILE COVE BASE- MATCH EXISTING 15, EXISTING CORNER GUARD TO REMAIN EXTENSION DRAWER SLIDES AT DRAWERS AND SHELVES. DRILL HOLES AND INSTALL 4. NEW 8x8 QUARRY TILE FLOORING - MATCH EXISTING 16. EXISTING WOOD BASE BOARD TO REMAIN GROMMETS FOR SMALL APPLIANCES TO PLUG IN BELOW COUNTER TOP. 5. EXISTING QUARRY TILE WAINSCOT TO REMAIN 17. NEW FORGED STEEL FOOT RAIL - DETAILS TO BE DETERMINED 26. STONE BACK & SIDE SPLASH, TYP. 6. EXISTING POCKET DOOR TO REMAIN - REFINISH DOOR AND PROVIDE NEW 1x3 ALDER CASING 18. NEW STONE BAR TOP W/ PLYWD, SUB-TOP AND WOOD CORBELS TO MATCH PANELED BAR 27. NEW SCONCE - MATCH EXISTING SCONCES. ON PANTRY SIDE OF OPENING. FRONT. 28. NEW ELECTRIC ROUGH-IN FOR KITCHEN EQUIP. PER SPECS. SEE ELEC. DRAWINGS 7. EXISTING DOOR OPENING LOCATION - INFILL WITH METAL STUD FRAMING AND i", W.R. TYPE 19. NEW STONE BACK BAR TOP W/ PLYWD. SUB-TOP - PROVIDE 1-1/2" WIDE VERTICAL PANELS 29. REMOVE EXISTING COUNTER TOP SUPPORT CLEAT AND PATCH WALL 'X' GYP. BRD. AT EACH SIDE OF 2-DOOR COOLER UNIT FOR COUNTERTOP SUPPORT - COORD. WITH 30. NEW WALNUT CROWN - PROFILE TO MATCH EXISTING- FINISH TO MATCH NEW BAR FRONT 8. NEW DOOR POCKET BEYOND KITCHEN EQUIP. SPECS. PROVIDE GROMMETS IN COUNTER TOP FOR ELECTRICAL AND AND BACK BAR 9. EXISTING ESPRESSO MACHINE AND COFFEE GRINDER PLUMBING CONNECTIONS FOR ESPRESSO MACHINE AND GRINDER. 31. EXISTING QUARRY TILE BASE TO REMAIN 10. NEW POCKET DOOR, FRAME AND CASING. PROVIDE NEW 1x3 ALDER CASING ON PANTRY SIDE 20. NEW WALNUT, RAISED PANEL BAR FRONT - FINISH AND DETAILS TO BE DETERMINED. 32. RECESSED, LED LIGHT IN TOP OF CABINET - SEE ELEC. DRAWINGS0 I C OF OPENING. PROVIDE NEW DOOR CASING ON BAR SIDE OF OPENING TO MATCH EXISTING 21. NEW GLASS FRONT, LOCKABLE, WALNUT LIQUOR CABINET WITH RECESSED LIGHTS AT TOP 33. UNDER-CABINET, LED LINEAR LIGHT - SEE ELEC. DRAWINGS. ,‘\<<". ° �� CASING. OF CABINET AND LINEAR STRIP LIGHT AT AT BOTTOM OF CABINET ABOVE BAR BACK TOP. 34. STONE CONDIMENT SHELF AND CORBELS. %.Z- ` OU 11. EXISTING AND NEW ELECT. RECEPTACLES - COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. PROVIDE 2 - 3/8" CLEAR GLASS SHELVES. a ELECTRIC CIRCUITS PER MANUFACTURER AND NEC CODE REQUIREMENTS. SEE ELEC. 22. 2 - 3/8" THICK CLEAR GLASS SHELVES FOR GLASSWARE. PROVIDE 1-1/2"x 1-1/2" PROFILED • CI) E S. 4 - ;. ERCE mV El / \ -/ 401494 /� J SSD ARC k 6°+ k 12 , 4 � / / .. - EXISTING WALL TO n REMAIN �, a ti 1 EXISTING F.R.P. _�____0) ,--,..-- tTO REMAIN \ 4 \ - \ / 20 a a "`t�� ,: i EXISTING QUARRY1 TILE BASE TO j REMAIN ` LT- _ 1 e .1 r v __ , v 1 v rie....-.s A y DETAIL- TYR BAR SECTION NEW INTER ELEV. - E3AR FRONT - EAST CO a1" = 1'-0" NOTE: NEW BACK BAR-SIMILAR 1/2" = 1'-0" I Reissued: Job No: 2340 Sheet No: w Austria Haus 0 Pantrl 4 Bar Remodel Drawn By: TSF CO 81657 . NOTE: PIERC 242 F. Meaoow or., Vail, Issue 03-10-16 PANTRY AND BAR EQUIPMENT NOT SHOWN FOR CLARITY, 0 1' 2' 4' + FRY Date: 30 W.Benchmark Rd,Ste.216 Tel:970.949.0899 EQUIPMENT PROVIDED AND NSTALLED BY OTHERS ____ /Won,Co 81620 ocaie: 1/2' = I'-0" TOv Stamp CO\ \ S f \G ,, \ I S NOMINAL CLG SATURATED OUTDOOR NOM. ELECTRICAL MANUFACTURER r® n � l MARK SERVES CAPACITY (TONS) SUCTION TEMP (CF) TEMP (OF) SEER REFRIG. VOLT/PHASE MCA MOCP 4 MODEL NO. SCE COPY CU-1 FC-1 2 45 95 14 1R-410a 208/1 14.1 25 CARRIER 244-444 24 Sea I ,.4..ivmoiNv ir ` A\ COILS ( ID X C001 \ � i 2`5000 : + i i sw 50 02 7 44'3 % c E.S.P. (IN W.C.) DX COOLING COIL ELECT. MANUFACTURER SERVES iF-PeD^ �••' � MARK CFM FLUID F� „ `;- S.L. a 815' S.MBH T.MBH EAT/LAT VOLT/PH MCA MOCP MODEL NO. 114• ,ti C;`,i`� _ • -4TGc: - - CARRIER PANTRY FC-1 &95 0" 0" 21.& 21.6 75/40 208/1 1 15 CLG: 1R-410a 40MfGCB22 PANS4 vS -fowl-, of Vail R 7iFVIEWED FOR CODE FAN - y '.:C*APL IANCE SYM. DESCRIPTION - - MANUFACTURER t .2 0.2- �U��, ,`�0 rate;_. __,_' � 2 CFM SP e SL W/A/HP VOLT SONES 4 MODEL NO. V S. O00 e ,o(;,de ___..__y EF-1 P4NTR� 121 0.25" 21 LJ 115/1 0.5 P4N4SONIC A 1 A 1, 2 EXi-4AUST FV-15VQ5 DAMPER: SUPPORT: DUCT CONNECTION: CONTROL: A. INTEGRAL GRAVITY 1. RIGID SUPPORT A. RIGID I. TIMER SUJITGH BACKED RAFT DAMPER 2. OCCUPANCY SENSOR DATE: 3/8/1a ss RADER1 AUSTRIA HAUS PROJECT #: 15018.00 t,� ENGINEERING • COMFORT SYSTEMS DRAWNErr: JAN 40&90 kla-kJ4Y &, SUITE EH PANTRY & BAR REMODEL CI-4ECKE1D B'-: BJH IN/I- 1 P.O. BOX a& 10 AVON, CO. 81&2 0 ( 1O) 84 --1910 / FAX: (910) 845 -1522 242 E. MEADOW DR., VAIL, CO 81657 SCALE: N/A SHEET 1 OF 3 ANY CHANGES AND/OR DEVIATIONS FROM THESE PLANS WITHOUT WRITTEN APPROVAL BY THE ENGINEER RELEASE THE ENGINEER FROM ANY FUTURE LIABILITY OR RESPONSIBILITY TO THIS BUILDING. RADER ENGINEERING, INC.EXPRESSLY RESERVE TI-4E COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS TO THESE PLANS. THIS DRAWING MAY NOT BE REPRODUCED OR PRODUCTIONS THEREOF USED WITHOUT WRITTEN PERMISSION FROM THE ENGINEER © COPYRIGHT 2sa15 RADER ENGINEERING, INC. TOV Stamp III ' ��% 36 35 34 e POOL EOUIP. Town of Vail 1n COMP � _I I, A I OFFIY LJ WI IJ 5� C= I i . .2 30 `—RELOCATE WATER FILTRATION Seal ia����t.A1 _ EQUIPMENT FROM BAR ABOVE. _ Q ; .. L1c 1 54 IDRAIN TO FLOOR DRAIN IN POOL M ' ���7tS1 EQUIPMENT ROOM. COORDINATE ,:r Cs ,.•,%�c.�'A �, ,9*..'.�`�''�fa • 3/8/16 . I EXACT LOCATION IN GARAGE WITH E °S% / BUILDING MANAGER. 5O O2 re :itim -::: � -O+ P �, D r ��i��0 . 4cc,�tc,i I itMP 4h4` iONAt. \''‘, I RELOCATE THERMOSTAT P 1 FC-1 ABOVE 1 TO THIS LOCATION n I WCI_ -1 1) �, HANG CU-1 CONDENSING UNIT U 11o_vro of �/aii �, �t FROM WALL. COORDINATE EXACT LOCATION UJITH 9 ti PLI N _ F f 1' _ Z ARA(_ ., to:__ _27_7- _-�... _ 7- --= ' - - RELOCATE THERMOSTAT ��_ _ _�-IP �, FURTHER INTO GARAGE. ----- ----- ---_ (SEE EAST GARAGE PLAN) G(,_ IIS''. I; a • - _ l, : ,___, _____ , _ T / \ i _ . _11E _ , L / 1\ i -- ELEVATOR- r MET y f'7 J AST C1,44,G. AN " A \ 1/8" = 11-0" NORTH 1/8" = 1I-0" NORTH mitADERI AUSTRIA HAUS DATE: 3/5/1& ® l/, PROJECT #: 15018.00 ENGINEERING • COMFORT SYSTEMSM PANTRY & BAR REMODEL DRAWN B'I': JAN M.20(090 IG -1WA'' &, SUIT — 1 CHECKEDB1': BJN P.O. 150X 0, 10 AVON, CO. 81&20 (910) 845-1910 / FAX: (910) 845-7522 242 E. MEADOW DR., VAIL, CO 81657 SCALE: 1/5" = 1'-0" SHEET 2 OF 3 ANY CHANGES AND/OR DEVIATIONS FROM THESE PLANS WITHOUT WRITTEN APPROVAL BY THE ENGINEER RELEASE THE ENGINEER FROM ANY FUTURE LIABILITY OR RESPONSIBILITY TO THIS BUILDING. RADER ENGINEERING, INC.EXPRESSLY RESERVE THE COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS TO THESE PLANS. THIS DRAWING MAY NOT BE REPRODUCED OR PRODUCTIONS THEREOF USED WITHOUT WRITTEN PERMISSION FROM THE ENGINEER. © COPYRIGHT 2015 RADER ENGINEERING, INC. TOV Stamp INSTALL NEW WALL CAP NEAR EXISTING WALL CAP AND AT LEAST 3' . FROM OPENINGS INTO TI-IE BUILDING. MATCH EXISTING WALL CAP TYPE. -fowl) ot Vali 4C- 1FICE Op iirti ______________ , , a (CS)) V / Seal `,.;��mew,1 T I _ I =c] VO0 Llt�ellgt RELOCATE WATER FILTRATION Pcti1v-"......... ip.i..`�<-)I H ❑I I D EQUIPMENT TO GARAGE BELOW AND i� ',50.4...-' # - � :,¢-� 3/8/16t RESTORE CONNECTIVITY TO • +, EXISTING FIXTURES RECEIVING e • 50 02 m i / . oRRiooR y — TREATED WATER.. 44 �, t : rz 7i ILII ._ i .�r.MN• �i a ili'iiNA/LL'' r III 1 g h o.`4aAR 1 1 I h C SEATING AREA �‘‘‘NOC 0. 447. 1 r c > � WALL TIMER SWITCH ,§1.lIC 'C-31 Cl OCCUPANCY SENSOR RELOCATE WALL PLATE I i AND JUNCTION BOX TO AN FC-1 [, - 4� r--- -- 1 �UwVY Ufi Vail ACCESSIBLE LOCATION. TI ��V����� �®�� ����ICI 1-- \ I '5 Date:�_ _ e 3' By: .�_....__-^—a� z I F code_ jl Cry� 3� / \ I N'A`�$i' - AIN r , [^1,I �i1 �� --0 Mil I I�, I I- - I I I I I I FA\ 1 F 4N 4i. 3/1&" = 1'-0" NORTI-1 BEIRADER1 AUSTRIA HAUS DATE: 3/8/1& ll, FR OJECT #: 15078.00 ENGINEERING • COMFORT SYSTEMSINI PANTRY & BAR REMODEL E)IRA UJN E3 : JA1-1 M.3 40&90 1HC�HIIUJ4X &, SUITE E - 1 CHECKED 15)': BJ1-I P.O. 80X a& 10 AVON, CO. 01&20 (9-10) 845 -1910 / FAX: (970) 845--122 242 E. MEADOW DR., VAIL, CO 81657 SCALE: 3/1& " = 11-0" SHEET 3 OF 3 ANY CHANGES AND/OR DEVIATIONS FROM THESE PLANS WITHOUT WRITTEN APPROVAL BY THE ENGINEER RELEASE THE ENGINEER FROM ANT FUTURE LIABILITY OR RESPONSIBILITY TO THIS BUILDING. RADER ENGINEERING, INC.EXPRESSLY RESERVE TI-4E COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHT5 TO THESE PLANS. THIS DRAWING MAY NOT BE REPRODUCED OR PRODUCTIONS THEREOF USED WITHOUT WRITTEN PERMISSION FROM THE ENGINEER. © COPYRIGHT 2015 RADER ENGINEERING, INC. 4 - - - TOV Stamp s , System No.C-AJ-1184 6v44), , S, ystem No.C-AJ-1421 Com®yUS F Rating--3 Hr C US ANSI/UL1479(ASTM E814) CAN/ULC 5115 Classified by T Rating--0 Hr Classified by Underwriters Laboratories.Inc. Underwriters Laboratories,Inc. F Rating—2 or 3Hr F Rating—2 or 3 Hr to UL 1479 and CANIULC-5115 to UL 1479 and CANIULGS115 'T Ratings—0 Hr FT Ratings—0 Hr `� a-A 2 L Rating At Ambient—Less Than 1 FH Rating—2 or 3 Hr OW rr.,: fl o �1 ori` CFM/sq ft e.� L Rating At 400 F—Less Than 1 FTH Ratings—0 Hr(See Item 3C) �^ C .' .Py CFM/sq ft :.:___:_7_,_ L L Rating At Ambient—Less Than 1 CFM/sq ft U L Rating At 400 F—Less Than 1 , , . 11 1 - CFM/sq ft - Sea I . 0O U l P 1 _; I 46 4B , pP ....... + ll �A 2 o'O'- t' J. .'0G SFQII) A 4 � _ i •co 6/27/16 T.. ��i SECTION A-A - ' _! % • 3g .. j / : 1.Floor or Wall Assembly--Min 4-1/2 in.thick reinforced lightweight or normal weight(100-150 pcf)concrete. �� b :• Wall may also be constructed of any UL Classified Concrete Blocks*.Floor may also be constructed of any min °' — i '0% I 'flO •• / , • 4, 7-1/2 in.thick UL Classified hollow core Precast Concrete Units`.Max diam of opening is 14 in.when concrete - J ,� C • •• ••••�� floor or wall is used and max 7 in.when precast concrete units are used. = 1 •••'• NGS See Concrete Blocks(CAZT)and Precast Concrete Units(CFN)categories in the Fire Resistance Directory for ll l•`S/0N A L E names of manufacturers. A 4A ,`'‘\\\\•b"4.." 2.Through-Penetrants--One metallic pipe,conduit or tubing to be installed either concentrically or eccentrically 3 within the firestop system.The annular space between pipe,conduit or tubing and periphery of opening shall be min 0 in.(point contact)to max 3-1/4 in.Pipe,conduit or tubing to be rigidly supported on both sides of floor or SECTION A-A wall assembly.The following types and sizes of metallic pipes,conduits or tubing may be used: — A.Steel Pipe--Nom 10 in.diam(or smaller)Schedule 10(or heavier)steel pipe. 1.Floor or Wall Assembly—Min 4-1/2 in.(114 mm)thick reinforced lightweight or normal weight(100-150 pcf or B.Iron Pipe--Nom 10 in.diam(or smaller)cast or ductile iron pipe. 1600-2400 kg/m3)concrete.Wall may also be constructed of any UL Classified Concrete Blocks*.Max diam of C.Conduit--Nom 4 in.diam(or smaller)steel electrical metallic tubing or steel conduit. opening is 6 in.(152 mm). D.Copper Tubing--Nom 4 in.diam(or smaller)Type L(or heavier)copper tubing. See Concrete Blocks(CAZT)category in the Fire Resistance Directory for names of manufacturers. E.Copper Pipe--Nom 4 in.diam(or smaller)regular(or heavier)copper pipe. 2.Metallic Sleeve—(Optional)Nom 6 in.(152 mm)diam(or smaller)Schedule 40(or heavier)steel sleeve cast 3.Forms--(Not Shown,Optional)--Used as a form to prevent leakage of fill material during installation.Forms or grouted into floor or wall assembly,flush with floor or wall surfaces. to be rigid sheet material,cut to fit the contour of the penetrating item and positioned as required to 3.Through-Penetrant—One metallic pipe or conduit to be installed either concentrically or eccentrically within accommodate the required thickness of fill material.Forms to be removed after fill material has cured.Additional the firestop system.The annular space between pipe,tube or conduit and periphery of opening shall be min 0 forming material may be used concrete block wall is penetrated.A min 1/2 in.thickness of min 4 pcf mineral wool in.(0 mm)(point contact)to max 5-3/8 in.(137 mm).Pipe or conduit to be rigidly supported on both sides of batt insulation is firmly packed into the annulus as a permanent form and recessed from both surfaces of the wall " fa-y as required to accommodate the required thickness of fill material. floor or wall assembly.The following types and sizes of metallic pipes or conduits may be used: E O V I , ot !r A.Steel Pipe—Nom 4 in.(102 mm)diam(or smaller)Schedule 10(or heavier)steel pipe. 4.Fill,Void or Cavity Material*--Sealant--Min 1 in.thickness of fill material applied within the annulus.At the Z ;b/y ® CODE B.Iron Pipe—Nom 4 in.(102 mm)diam(or smaller)cast or ductile iron pipe. t/ 1/4� point contact location between through penetrant and concrete,a min 1/2 in.diam bead of fill material shall be C.Copper Pipe—Nom 4 in.(102 mm)diam(or smaller)Regular(or heavier)copper pipe. eN applied at the concrete through penetrant interface.When precast concrete units are used,the fill material shall P, ,O �j R D.Copper Tubing—Nom 4 in.(102 mm)diam(or smaller)Type L(or heavier)copper tubing. , ;API I_ �L be installed within annular space,flush with lower surface of floor.When concrete block wall is penetrated,a min E.Conduit—Nom 4 in.(102 mm)diam(or smaller)steel conduit. 1 in.thickness of fill material shall be applied within the annulus flush with both surfaces of wall. F.Conduit—Nom 4 in.(102 mm)diam(or smaller)steel electrical metallic tubing(EMT). ` HILT!CONSTRUCTION CHEMICALS,DIV OF HILTI INC--FS605 or FS-ONE Sealant 4.Firestop System—The firestop system shall consist of the following: Date-._, L. L _� 'Bearing the UL Classification Mark A.Packing Material—Min 4 in.(102 mm)thickness of min 4 pcf(64 kg/m3)mineral wool batt insulation firmly 4, packed into opening as a permanent form.Packing material to be recessed from top surface of floor or from V tJ_ PI,IMMIM, both surfaces of wall as required to accommodate the required thickness of fill material. Reproduced by HILTI,Inc.Courtesy of B.Fill,Void or Cavity Material*-Sealant—Min 1/4 in.(6 mm)thickness of fill material applied within the `'f Underwriters Laboratories,Inc. t.r( t_ l . March 12,1999 annulus,flush with top surface of floor or with both surfaces of wall.For 3 Hr rated assemblies,a min 1/4 in. Hilti Firestop Systems (6 mm)diam bead of fill material shall be applied at the concrete/pipe interface at the point contact location on the top surface of floor and on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS,DIV OF HILTI INC—FS-ONE Sealant or CP604 Self-Leveling Firestop Sealant.CP604 shall be used in floor applications only. When CP604 is used,F Rating is 2 Hr. *Bearing the UL Classification Mark 1114,IMMr., Reproduced by HILTI,Inc.Courtesy of Underwriters Laboratories,Inc. November 21,2012 Hilti Firestop Systems DATE: ',,-,'- Iii 1:1 A D E Et t AUSTRIA HAUS fi�ROJECT #/'SO-1S.Om ENGINEERING • COMFORT SYSTEMS PANTRY & BAR REMODEL DRAWN BY- JAI IN'I44ro 0 90 I-I IG 1-IW 4Y &, SUITE E - 1 C-IECKED BY: �JN P.O. BOX 8010 AVON, CO. 81&20 (910) 845-1910 / FAX: (910) S4 -1522 242 E. MEADOW DR., VAIL, CO 81657 SCALE: N/A S;--4EET4OF4 ANY CHANGES AND/OR DEVIATIONS FROM THESE PLANS WITHOUT WRITTEN APPROVAL BY THE ENGINEER RELEASE THE ENGINEER FROM ANY FUTURE LIABILITY OR RESPONSIBILITY TO THIS BUILDING. RADER ENGINEERING, INC.ExPRESSLY RESERVE THE COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS TO THESE PLANS. THIS DRAWING MAY NOT SE REPRODUCED OR PRODUCTIONS THEREOF USED WITHOUT WRITTEN PERMISSION FROM THE ENGINEER. © COPYRIGHT 205 RADER ENGINEERING, INC. TOV Stamp Seal SHEET LIST GENERAL NOTES `�,,,-\-\\.\\x‘` ll E-1.0 LEGEND, ABBREVIATIONS AND SYMBOL LIST 1. ALL WORK SHOWN IS NEW, UNLESS NOTED OTHERWISE. _77G�pDU ... 6.11i 2. ALL WORK TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE, 2014 EDITION. %�0N•:� G OARLe•:cf• it E-1.1 SINGLE LINE DIAGRAM *.',O 3. SEAL ALL CONDUIT PENETRATIONS OF FLOORS AND FIRE RATED ASSEMBLIES TO i ,it CI r i E-1.2 PANEL SCHEDULES AND LIGHTING FIXTURE SCHEDULE MAINTAIN FIRE RATING. Z 49009m: f E-2.0 POWER PLAN - MAIN LEVEL 4. PROVIDE NEW TYPEWRITTEN DIRECTORIES REFLECTING WORK PERFORMED FOR ALL yowl, oyV �� rr ,11- NEW PANELBOARDS IN THIS PROJECT. / � ' E-2.1 POWER PLAN - GARAGE LEVEL r. %; 5. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT k" " ti `,ir c t ,, r 11111 ONAL EN = E-3.0 LIGHTING PLAN NUMBERS. PROVIDEITTIN AND INSTALL ALL CONDUITS,A COMPLETE ANDNDUCTORS,OPERABLE BOXES,SYSTEM ; �� 1 F �Y� \\�\���i MISCELLANEOUS GS, ETC. .- E-4.0 SPECIFICATIONS - PART 1 (HOMERUN SHOWN). BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATIONS AND N.E.C. E-4.1 SPECIFICATIONS - PART 2 6. ALL NEUTRAL CONDUCTORS ON POWER BRANCH CIRCUITING ROUNDHOUSES TO BE #10 AWG UNLESS NOTED OTHERWISE. ABBREVIATIONS NOTES AUSTRIA HAUS SYMBOLS WIRING DEVICE SYMBOLS SYMBOLS POWER SYMBOLS NOTES A, AMP AMPERE PANTRY & BAR REMODEL AC ABOVE COUNTER TOP n STATIONARY — CIRCUIT BREAKER; RATING AS 242 E.Meadow Dr. 20A, 125V, DUPLEX RECEPTACLE OUTLET +18" UNLESS NOTED OTHERWISE o 0 SHOWN ON PLANS AIC AMPERE INTERRUPTING CAPACITY Vail,CO 81657 09SURFACE 20A, 125V, DUPLEX RECEPTACLE OUTLET +18" UNLESS NOTED OTHERWISE -0'..""0-0= SWITCH AND FUSE; RATING AS SHOWN ON PLANS AFF ABOVE FINISHED FLOOR AF FRAME RATING IN AMPERES -4 20A, 125V, DOUBLE DUPLEX RECEPTACLE OUTLET +18" UNLESS NOTED OTHERWISE -oi"'"o-,J . SWITCH AND FUSE; RATING AS SHOWN ON PLANS �y AS SWITCH RATING IN AMPERES PIERCE Pe SURFACE 20A, 125V, DOUBLE DUPLEX RECEPTACLE OUTLET +18" UNO , 0 JUNCTION BOX AT TRIP RATING IN AMPERES + FRYE SPECIAL PURPOSE RECEPTACLE OUTLET, +16" UNLESS NOTED OTHERWISE, NEMA SURFACE MOUNTED PANELBOARD OR TERMINAL CABINET AWG AMERICAN WIRE GAUGE ARCHITECTS CONFIGURATION AS NOTED ON PLANS C CONDUIT 30 W.Benchmark Rd.Ste.216 FLUSH MOUNTED PANELBOARD OR TERMINAL CABINET CL CENTERLINE Avon,CO 81620 KO SURFACE SPECIAL PURPOSE RECEPTACLE OUTLET, +18" UNLESS NOTED OTHERWISE, NEMA CONFIGURATION AS NOTED ON PLANS CKT CIRCUIT SYMBOLS DESIGNATION SYMBOLS NOTES CLG CEILING 7 ( L �( se 20A, 125V, DEDICATED DUPLEX RECEPTACLE OUTLET +18" UON DIST DISTRIBUTION 0001G DUPLEX OUTLET WITH ISOLATED GROUND O COLUMN LINE (E) EXISTING TO REMAIN EC EMPTY CONDUIT / C P DUPLEX OUTLET WITH WEATHERPROOF COVER ELEC ELECTRICAL IIII 15ONG FEEDER DESIGNATION TAG / EM EMERGENCY 41:03GFI DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER F1 DETAIL REFERENCE BUBBLE EMT ELECTRO METALLIC TUBING ® FLUSH MOUNTED 20A, 125V, DUPLEX RECEPTACLE OUTLET A DETAIL NUMBER EWC ELECTRIC WATER COOLER ® FLUSH MOUNTED 20A, 125V, DOUBLE DUPLEX RECEPTACLE OUTLET E1.1 SHEET BEARING DETAIL EWH ELECTRIC WATER HEATER FA FIRE ALARM WILDER ENGINEERING LLC ® CEILING MOUNTED 20A, 125V, DUPLEX RECEPTACLE OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPTING Andrew Wilder PE A o FIXTURE DESIGNATION 1170 Blue Sage Drive 22 UPPER CASE LETTER INDICATES FIXTURE TYPE. G, GND GROUND Springs, 80487 0 CEILING MOUNTED 20A, 125V, DOUBLE DUPLEX RECEPTACLE OUTLET LOWER CASE LETTER INDICATES SWITCH LEG HP HORSEPOWER Steamboat 970-819-7848rings,COO NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN). --�-=== PLUG STRIP TYPE , OUTLETS, SPACING AND FINISH AS LETTER INDICATES FIXTURES CONTROL (WHERE SHOWN) MECH MECHANICAL E:andy@wilder-eng.com NOTED ° MCB MAIN CIRCUIT BREAKER Issue By Date&Issue Description By NORMALLY CLOSED SPST WALL SWITCH, LETTERS INDICATE THE NUMBER OF SWITCHES AND OUTLETS 2 NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN) NC PERMIT SET — 3.8.16 AW THEY CONTROL NEC NATIONAL ELECTRIC CODE 3 THREE WAY SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION SYMBOLS LIGHTING SYMBOLS NO NORMALLY OPEN IK KEY OPERATED SWITCH NTS NOT TO SCALE ID DIMMER SWITCH 2'x4' LED SURFACE FIXTURE - SEE FIXTURE SCHEDULE PB PULL BOX 0, PH PHASE I1NP SINGLE POLE WEATHERPROOF SWITCH 0 LED DOWN-LIGHT FIXTURE - SEE FIXTURE SCHEDULE PNL PANEL ILV LOW VOLTAGE CONTACT SWITCH o LED WALLWASH FIXTURE - SEE FIXTURE SCHEDULE PVC POLYVINYL CHLORIDE CONDUIT PWR POWER 1M MOMENTARY CONTACT SWITCH RSC RIGID STEEL CONDUIT scale CEILING MOUNTED LED EXIT SIGN :11x17 NTS TEL TELEPHONE OS OCCUPANCY LIGHT CONTROL SWITCH; CEILING MOUNTED TYP TYPICAL Description:LEGEND,SYMBOLS ItEMERGENCY BATTERY UNIT IDS OCCUPANCY LIGHT CONTROL SWITCH; WALL MOUNTED UON UNLESS OTHERWISE NOTED V VOLT Project Name:AUSTRIA HAUS VA VOLT AMPERES Project Number:201603 W WATT WP WEATHERPROOF XFMR TRANSFORMER Sheet No. E-1.0 Inv Ctanil, sr.:I VON.VANAk ..:7"..�pD0 t/C 14I E Cc\�GHARi • (111 if i f ' CORRIDOR 105 a 490 f CT CABINET //1a ` � �� ,t14,4 pNAL ENG`- PNL- BP 100A 1 11 eMLO UTILITYAUSTRIA HAUS METER 1 (: .,,100A FEEDER PANTRY & BAR lREMODEL _MAIN LEVEL 242 E.Meadow Dr. PARKING GARAGE MAIN ELECTRIC ROOM Vail,CO 81657 MAIN DISTRIBUTION PANEL MDP 208/120V, 2000-AMP, 3PH, 4W, 65K AIC PIERCE TO UTILITY + FRYE POWER TFa l OWE I of V ARCHITECTS 1 E V I EWE 30 W.Benchmark Rd.Ste.216 100AF/100AS v n M Avon,CO 81620 o 3P -• � 11 iirT EXISTIN6'OMP I o--- - Date: 7 ( t_ •-(-� /200A FEEDER 200AF/200AS " . 3 a✓ EXISTING 1// 0 •—LJ}-0..„.o DEXISTING i / 200AF/200AS EXISTING 2P EXISTING 4 o/o-1=1:1- • • LL11-0� EXISTING • • • EXISTING EXISTING WILDER ENGINEERING LLC PNL- EXISTING 4--1---0ff 0--E1=-0.„5:0--1—>EXISTING Andrew Wilder PE P 1 B 2000AF 1170 Blue Sage Drive 200A 2000AS Steamboat Springs,CO 80487 MLO 3P P:970-819-7848 EXISTING EXISTING E:andy@wilder-eng.com EXISTING < 0 l—• 9 111-0=1-o o EXISTING Issue By Date&Issue Description By - PERMIT SET - 3.8.16 AW EXISTING EXISTING EXISTING 4 I o/o--0=1:1—• •---II II-o�o EXISTING rim N L _ L__ I LIEN G i! GARAGE LEVEL — GROUNDING ELECTRODE CONDUCTOR Scale: DIAGRAM NOTES 11017 NTS 1. ALL WORK SHOWN IS EXISTING UNLESS OTHERWISE NOTED. Description:SINGLE LINE DIAGRAM 2. BRING ANY DISCOVERED CODE VIOLATIONS TO THE OWNER'S ATTENTION. Project Name:AUSTRIA HAUS Project Number:201603 41/ SINGLENTS LINE DIAGRAM Sheet No. E-1.1 TOV Stamp Seal LIGHTING FIXTURE SCHEDULE .z..---(0,00 tic v- -,HARL Fy tI(r SYMBOL ITEM TYPE SIZE LAMPS i ��� G Fd` •�Fa7 FIXTURE INPUT CATALOG ALTERNATE CATALOG v,to fi TYPE COLOR VOLTAGE WATTS NUMBER NUMBER �Zo o; V ELCO APPROVED EQUAL - CONTRACTOR TO SUBMIT %bra 49009b, "P Fl RECESSED LED DOWNLIGHT 4" LED 2700 120 5.6 7j e% EL1499ICA WITH EL1493W TRIM ANY SUBSTITUTION TO DESIGN TEAM FOR APPROVAL ''r1 '"G\ APPROVED EQUAL - CONTRACTOR TO SUBMIT 11111\\ONAL c., .. F2 SURFACE MOUNTED LED 4' STRIPLIGHT 4' LED 3500 120 44 CREE ANY SUBSTITUTION TO DESIGN TEAM FOR LS4-40L-35K-1 OV APPROVAL 1-431- APPROVED EQUAL - CONTRACTOR TO SUBMIT F3 SCONCE - TO MATCH EXISTING TBD INCANDESCENT 3000 120 50 TO MATCH EXISTING ANY SUBSTITUTION TO DESIGN TEAM FOR �r •CONTACT OWNERSHIP FOR FIXTURE TYPE APPROVAL ` �� � � AUSTRIA HAUS APPROVED EQUAL - CONTRACTOR TO SUBMIT 4'L � 4'` ' PANTRY & BAR = F4 UNDERCABINET LED 24" LED 3000 120 13.1 LITHONIA LIGHTING SERIES ANY SUBSTITUTION TO DESIGN TEAM FOR - RAZ 24-TRANS24/120 APPROVAL REMODEL 242 E.Meadow Dr. Vail,CO 81657 APPROVED EQUAL - CONTRACTOR TO SUBMIT �Fr 1 Vali I�� X1 BATTERY BACKUP EGRESS FIXTURE 5"x12" INCANDESCENT NA 120 11 LITHONIA LIGHTING SERIES ANY SUBSTITUTION TO DESIGN TEAM FOR �/ �A� ELM2 APPROVAL ry fir-VIE 1/!9 E D FOR ._'OMPLIANIC . PIERCE SCHEDULE NOTES + 2- '.� + FRYE 1. ALL LAMPS SHALL BE PROVIDED BY THE CONTRACTOR. Date:. ( ARCHITECTS 2. CONTRACTOR TO SUBMIT FIXTURE TYPES TO OWNER AND ENGINEER PRIOR TO PURCHASE AND INSTALLATION. t, ; 30 W.Benchmark Rd.Ste.216 Avon,CO 81620 O LIGHTING FIXTURE SCHEDULE If— NTS fNTS EXISTING EXISTING MOUNTING RECESSED PANEL BP 10.000 A.I.C. SYM MOUNTING SURFACE PANEL P1 B 22,000 A.I.C. SYM 208/120 VOLTS 3 PHASE 4 WIRE MAIN MLO BUS 100 A 208/120 VOLTS 3 PHASE 4 WIRE MAIN MLO BUS 200 A 1111 r r r r VOLT AMPS R L 0 8 C C BOLA VOLT AMPS VOLT AMPS RLOB C C BOLR VOLT AMPS ET LK I I KIT E - - ET L K 1 I KIT E O A O B O C DESCRIPTION C G E R R R R E G C DESCRIPTION O A O B O C O A O B O C DESCRIPTIONC G E R R R R E G C DESCRIPTION OA OB DC (1) 3172 (N)Dishwasher 2 40 1 A 2 20 1 Lighting 750 1800 AC Unit 2 30 1 A 2 30 2 AC Unit 1800 WILDER ENGINEERING LLC (1) 3172 - - - 3 B 4 20 1 Refrigerator 1200 (1) 1800 - - - 3 B 4 - - - 1800 Andrew Wilder PE 750 Lighting 1 20 5 C 6 _20 1 Coffee Machine 1200 (1) 1800 AC Unit 2 30 5 C 6 30 2 AC Unit 1800 1170 Blue Sage Drive (1) 1200 Toaster 1 20 7 A 8 20 1 6 Recepts 1080 1800 - - - 7 A 8 - - - 1800 Steamboat Springs,CO 80487 P:970-819-7848 1080 Recepts 6 1 20 9 B 10 20 1 Blender 1000 (1) 1800 AC Unit 2 30 9 B 10 30 2 AC Unit 1800 E:andy@wilder-eng.com 500 POS 1 20 11 C 12 20 1 Brewer 1000 (1) 1800 - - - 11 C 12 - - - 1800 (1) 1000 Grinder 1 20 13 A 14 20 2 Coffee Machine 1000 (1) 1000 AC Unit 2 20 13 A 14 50 2 AC Unit 2600 (1) 1200 Cooler 1 20 15 B 16 - - - 1000 (1) 1000 - - - 15 B 16 - - - 2600 Issue By Date&Issue Description By 1080 Receps 6 1 20 17 C 18 20 1 6 Recepts 1080 1080 Recepts 6 1 20 17 C 18 20 2 AC Unit 1000 - PERMIT SET — 3.8.16 AW 27 (N)EF-1 1 15 19 A 20 20 1 Ice Machine 1000 (1) Spare 2 20 19 A 20 - - - 1000 500 Power Pack 1 20 21 B 22 20 1 1 (N)Buffet 180 - - - 21 B 22 20 1 Refrigerator 1200 (1) 1200 Cooler 1 20 23 C 24 20 1 1 (N)Buffet 180 Spare 2 20 23 C 24 20 1 Freezer 1200 180 (N)Buffet 1 1 20 25 A 26 20 1 6 Recepts 1080 - - - 25 A 26 30 2 (N)CU-1 1466 (1) (1) 2390 (N)Oven 2 30 27 B 28 30 2 Coffee Machine 1800 (1) 1200 Freezer 1 20 27 B 28 - _- - 1466 , (1) 2390 - - - 29 C 30 - - - 1800 (1) 1080 Workbench 6 1 `20 29 C 30 15 2 (N)FC-1 110 (1) _5579 8342 5920 VA LINE 4910 5180 5260 Space 31 A 32. - - - 110 OA= 10489 0W 13522 0C= 11180 Space 33 B 34 20 1 (N)OmeletteSin 1500 (1) CONTINUOUS LOADS NON-CONTINUOUS LOADS Space35 C 36 20 1 (N)Omelette Stn. 1500 (1) UP TO 10 kVA 5940 x1.00= 5940 KITCHEN 26724- x0.65= 17371 Space 37 A 38 20 1 (N)OmeletteStn. 1500 (1) 1500 x115= 1875 RECEPTACT FS Space 39 B 40 201 (N)Omelette Stn. 1500 (1) REMAINDER x0.50= OTHER 1027 x1.00= 1027 Scale: Space 41 C 42 Space 11217 NTS TOTAL DESIGN kVA= 26 TOTAL DESIGN AMPS= 73 4600 5800 5760 VA LINE 10276 11866 7410 Description:SCHEDULES (1)Kitchen equipment,demand factor applied per NEC 220.56. 0 A= 14876 0 W 17666 0 C- 13170 CONTINUOUS LOADS NON CONTINUOUS LOADS UP TO 10 kVA 8160 x1.00= 8160 Project Name:AUSTRIA HAUS PANEL NOTES x115 RECEPTACLES OTHER 37552 x1.OD 37552 REMAINDER x0.10 Project Number:201603 1. ALL LOADS SHOWN ARE EXISTING, UON. TOTAL DESIGN kVA= 46 TOTAL DESIGN AMPS= 127 © PANELBOARDNTS SCHEDULES (1)Providenew breaker asshown. Sheet No. E-1. TOV Stamp / '.a\.\\t\tr>.,. / PPD 0 1/C 14 OMi of Vail —pv�-C,4AR( . ,fl_fliit t /' LJ 4 EVI EWER FOR C4 % et- -.a COMP LI,A r' . ,i 49009 m, ..: F - - e — `r- 7 X111 (0N-A-LEN �_ �P • I.I•- 9� - (*law'''i'''4 AUSTRIA HAUS I \ — POWER PLAN SHEET NOTES ar ,. l . PANTRY & BAR 1- 1. ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED. REMODEL 242 E.Meadow Dr. 1 ( 1 2. PROVIDE TYPEWRITTEN DIRECTORIES REFLECTING ALL Vail,C081657 ' NEW WORK PERFORMED IN THIS PROJECT. )p 1I T T L 105 CORRIDOR LIMIT OF WORK 3. LABEL ALL ELECTRICAL DEVICES INCLUDING RECEPTACLES + FRYE P1B 31 WITH PANEL NAME AND CIRCUIT NUMBER. PIERCE ARCHITECTS GFI °© I 30 W.Benchmark Rd.Ste.216 " z l— P1B-3 ' 4. ALL WIRE SHALL BE #12 AWG MIN., 90 DEG. "C" IN Avon,CO81620 i 1 COOLIE R15I GFI=- © 1/2'C — 2#12 AWG & #12 GND, UNLESS OTHERWISE NOTED. 3RINDER�2BAR P1BFI= `© I ' 4511G3P1B�41► II 5. VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT WITH AC,IGFI 0 __,© ARCHITECTURAL DRAWINGS AND EXISTING CONDITIONS IN (E)PANEL BP ' I 103 SEATING AREA THE FIELD. COFFEE il o X16 / 6. ALL EQUIPMENT SHOWN IS CONNECTED TO PANEL 'BP', UON. AL H= 1 �ICEO5 a 0(E) 7. BRING ANY DISCOVERED CODE VIOLATIONS TO THE OWNER'S g 1 ATTENTION. 4� 310 25 WILDER ENGINEERING LLC ��II 1 Andrew Wilder PE ® 0�E�MW (E)REFO yceg , A ,GFI 1170 Blue Sage Drive SHEET NOTES SteambPoaat Springs,9CO80487 1 P1 B-30,32 r 1 I E:andy@wilder-eng.com 4, T L — �1I wAlla cc2p41 1 VERIFY CONNECTION TYPE WITH MANUFACTURER PRIOR TO INSTALLATION. /� �' V v v O Issue By Date&Issue Description By ® 1 • AC�,GFI I 2LABEL RECEPTACLE, 'OMELETTE STATION'. - PERMIT SET — '.B.'6 AW .. m LPt---, I 0 rel PANTRY 32�j,29 O3 PROVIDE OVEN WITH 3/4"C - 2#10 AWG & #10 GND. PROVIDE I `1' 22 104 SERVING T,.. 19 VING ANEMA TYPE L6-30R PLUG, CONFIRM WITH MANUFACTURER PRIOR TO 0 1,GFI ' INSTALLATION. e(E) 14, 6 . VERIFY NEW DISHWASHER IS TO BE INSTALLED. REMAINING CIRCUITING �dFFEE O5 I11►1+1��(E! o V V V1 TO REMAIN IF NOT. PROVIDE NEW 40-AMP, 2POLE BREAKER IN / I�11►I - - _ _ _ _ _ PANEL AND FEED WITH 1/2"C - 2#8 AWG & #10 GND. LJ <> RELOCATE EXISTING EQUIPMENT TO LOCATION SHOWN. EXTEND AND Scale11x17 14`1'-0' \ \ RE-ROUTE CIRCUITING AS NECESSARY. Description:POWER PLAN 0 POWER PLAN — MAIN FLOOR \ \ \ \ \ \ Project Name AUSTRIA HAUS / \ 1 4"—1 '—0 ' \ \ \ \ Project Number:201603 100 LOBBY \ 7.----- Sheet No. �1 \ E-2.0 III rov,. sNai l. .V�•�O'HAR(FS-rd, II' It ;4, •<L•or 1z 49009 m; �'3;i , •�„, L __- 1'1 NA .. ` POOL EQUIP. (E)PANEL P1 B (E)MDP :: 'k` ® GENERAL NOTES AUSTRIA HAUS GI ' ' PANTRY & BAR I] __ //A\\: K'-----=. 1 . ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED. REMODEL O o / 242 E.Meadow Dr. I I ---I 1--- - — Vail,CO 81657 ELEC. RM 2. PROVIDE TYPEWRITTEN DIRECTORIES REFLECTING ALL NEW WORK PERFORMED IN THIS PROJECT. C1-7 PIERCE - 0 3. LABEL ALL ELECTRICAL DEVICES INCLUDING RECEPTACLES + FRYE WITH PANEL NAME AND CIRCUIT NUMBER. ARCHITECTS 30 W.Benchmark Rd.Ste.216 4. ALL WIRE SHALL BE #12 AWG MIN., 90 DEC. "C" IN ARon,CO TECTS0 5 1/2'C - 2#12 AWG & #12 GND, UNLESS OTHERWISE NOTED. OMP 4 3 2 1 a -� COMP Ar II — 5. VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT WITH ARCHITECTURAL DRAWINGS AND EXISTING CONDITIONS IN — 0 THE FIELD. 6. BRING ANY DISCOVERED CODE VIOLATIONS TO THE OWNER'S ATTENTION. GARAGE ENTRY SHEET NOTES WILDER ENGINEERING LLC Andew Wilder PE LLC 1170 Blue Sage Drive 9 11 PROVIDE MECHANICAL UNIT WITH 1/2 C - 2#10 AWG & #10 GND. " Steamboat Springs,CO 80487 P:970-819-7848 E:andy@wilder-eng.com (CU ) ue By Dale&Issue Descry,t oe 6V • L- o o El o - PERMIT SET - 3.8.16 AW ❑ WL JI - Towns of Vail 2;AF 0 2P - REVIEWED F 0b r 1 i iCOMPLIANCE (----- ELEVATOR LOBBY P1B-26,2801 Date:_ - Z ,K..„..: _ e 4 Abode f scale: = N/j 11x17 1/8".1,-0 e N-'0 W E R PLAN - GARAGE Description POWER PLAN-GARAGE = Ii) 8''=1 '—0" PEll Project Name:AUSTRIA HAUS Project Number:301603 L ,. , Sheet No. P E-2.1 / ��p D ORC I�Fy�Ff, / Q town of Vali ic-Ct. 4,, FS ��,,roff fR E'JIEWED FOR C �) 49009 m; — — — • .. I COMPLIANCE 'h,0 �. .44r �7 a ,. _ )_ h ONAL ..,-........-2- ,• — V— �I■ - — ■ISI■ - - 'I�, • f.:r,�..�• 'll`,‘‘i,,`C`�,'.r I l P� �A - v • ._. - 9 J❑I� F1 ❑ ;14C d F1 F1 REd IC d LIGHTING PLAN SHEET NOTES T I \\ AUSTRIA HAUS __ F3 1 . ALL LIGHTING EQUIPMENT AND CONTROLS SHOWN ARE PANTRY & BAR e NEW UNLESS OTHERWISE NOTED. REMODEL O O Vail,CO 81657 Dr. 1' X1 1 ' EM 2. ALL LIGHTING FIXTURES WITH THE 'EM' DESIGNATION ARE TO BE CONNECTED TO AN EMERGENCY BATTERY FOR EGRESS Fl _ F1 _ _ F1 \ LIGHTING AND NOT TO BE SWITCHED FOR NIGHT LIGHTING. PIERCE T T 105 CORRIDOR E r10 ,, ;; c _ 11 C 1 LIME OF WORK + FRYE o g / CONFIRM LOCATIONS OF ALL LIGHT SWITCHES WITH THE ARCHITECTS ��,�_ — F1 (E) ARCHITECT AND TENANT PRIOR TO INSTALLATION. 30 W.Benchmark Rd.Ste.u6 „J • — F1 l i C LJ C I �1 I ^ Avon,CO 81620 1 b ,. lJ 4. ALL WIRE SHALL BE #12 AWG MIN., 90 DEG. "C" IN 1 102 BAR C I 103 SEATING AREA 1/2'C — 2#12 AWG & #12 GND, UNLESS OTHERWISE NOTED. I 1 I ' 5. ALL EQUIPMENT SHOWN IS CONNECTED TO PANEL "BP', UON. qi (E)PANEL BP ' I F1 ;Ft1 1 r,1. • ,, c 6. PROVIDE TYPEWRITTEN DIRECTORIES REFLECTING ALL NEW WORK ,I.J ° � _ ���Fl �Fl ! O _ PERFORMED IN THIS PROJECT. \11 1 x C �.g C ftib DDDDDD e E3 7. CIRCUITING SHOWN IS BASED ON EXISTING CONDITIONS. S S S S S S CONTRACTOR TO NOTIFY DESIGN TEAM OF ANY CIRCUITING l; ! �,�F1 1 ISSUES THAT ARISE IN THE FIELD. WILDERENGINEERINGLLC 1 Andrew Wilder PE u �„JE 1170 Blue Sage Drive 0 I Steamboat Springs,CO 80487 F 1 P:970-819-7848 riallim 1 E:andy@wilder-eng.com '\ Z\ Fl ' r' (E) LJ LIGHTING PLAN NUMBERED NOTES r L F2 F 1 ����e Issue BY Date&Issue Descnp0on By <> CONNECT NEW LIGHT FIXTURES TO EXISTING CIRCUITING - PERMIT SET — 3.8.16 AW ■ _ _! _© ..° '°F2 I r11 LOCATED IN THE CEILING. RE—WIRE TO NEW SWITCH r e 101 PANTRY LEGS AS SHOWN. H „,F1 I O2 PROVIDE AN UNSWITCHED HOT CONDUCTOR FROM CIRCUIT e 104 SERVING AREA 1 I SHOWN FOR PROPER OPERATION OF EMERGENCY EGRESS Ian F2 2 a ' FIXTURE. III 4e3 O NEW SWITCHES 'f' AND 'g' ARE TO BE CONNECTED TO 1 I ° — — — — — — ' — EXISTING LIGHT FIXTURES IN SEATING AREA. Scale. 11217 LIGHTING” IDescription:LIGHTING PLAN 1 LIGHTING PLAN — MAIN FLOOR Project Name:AUSTRIA HAUS I0 1 4 =1 —0 Project Number:201603 I I 100 LOBBY Sheet No r -----la E-3.0 SECTION 16010-BASIC ELECTRICAL REQUIREMENTS SECTION 16100-BASIC MATERIALS AND METHODS .,,��Pp d ",1tk! 1)PART 1 GENERAL 1)PART 1 GENERAL �vQr --- L IVIii a)POWER AND CONTROL WIRING a)REFERENCES V ,'S1 FS+ ,f0 ? i) Provide power system conduit and wiring to mechanical equipment. Controls system conduit and wiring for i) All equipment and installations shall meet or exceed minimum requirements of ADA,ANSI,ASTM,IEEE,IES,NEC,NEMA, / 'Q�/ L', • mechanical systems is included under Division 15. "Power"wiring includes line voltage wiring from distribution NETA,NFPA,OSHA,SMACNA,UL,and the State Fire Marshal. Equipment shall be certified for use in the State of the ' :p r apparatus to disconnecting means provided or installed under this section,and from such disconnecting means to project and shall meet the State energy code. Provide products and materials that are new,clean,free of defects,and / ',Q 49009 m, motors,and to terminal boxes of'package'equipment. "Controls"wiring includes wiring,regardless of voltage,which free of damage and corrosion. 0... provides start-stop control for mechanical equipment and/or which is used to monitor functions of mechanical b)PERFORMANCE REQUIREMENTS 6-53 „", systems. Where line voltage wiring is extended from a local disconnecting means to relays,thermostats,by-pass .'1� " __ ��t timers,starter coils or the like,or from mechanical control panels or motor control centers to control devices,such i) Provide support system for equipment and conduit,including wiring,with a minimum safety factor of 4. For empty f(! ""NCj' 4.7 extensions are considered"control"wiring. conduits,include weight of 4 type XHHW wires of maximum permissible size. SIA,OMAL E�,�.. b)MOUNTING HEIGHTS c)QUALITY ASSURANCE \",\�""' i) Mounting heights and locations:verify the exact location of equipment with architect prior to installation. Wall i) All equipment and installations shall meet or exceed minimum requirements of ADA,ANSI,ASTM,IEEE,IES,NEC,NEMA, mounted devices requiring operational access shall be mounted a minimum of 15 inches above finished floor to NETA,NFPA,OSHA,SMACNA,UL,and the State Fire Marshal. Equipment shall be certified for use in the State of the bottom of device and a maximum of 48 inches above finished floor to top of device.Visual alarms shall be mounted project and shall meet the State energy code. Provide products and materials that are new,clean,free of defects,and not less than 80 inches to the bottom or 96 inches to the top of the device. free of damage and corrosion. c)REGULATORY REQUIREMENTS i) Conform to: 2)PART 2 PRODUCTS AUSTRIA HAUS (1) NFPA-70-National Electric Code. a)CONDUIT PANTRY & BAR ii)Comply with the current applicable codes,ordinances,and regulations of the authority or authorities having i) General �'` y p/r p� Vail' REMODEL jurisdiction,the Owner's insurance underwriter,and applicable base building standards. (1) Exposed Dry and Damp Locations: REVIEWED 'o YY 1 V1i�fV a�G 242 E.Meadow Dr. iii)When conflict exists between two or more governing codes,comply with the stricter requirement. (a)Use electrical metallic tubing. R EV I E Y N E D FO R CODE. Vail,CO 81657 iv)Obtain permits,and request inspections from authority having jurisdiction. (2) Concealed Locations: d)PROJECT/SITE CONDITIONS (a)Furred,Ceiling Spaces and Stud Walls: Use electrical metallic tubing. CO F F I I^Q°"N r(E // i i) Install Work in locations shown on Drawings,unless prevented by Project conditions. Coordinate installation of work (b)Connections to Lighting Fixtures in Accessible Ceilings: Use flexible conduit. Date. 7 / 1 / 7,C, PIERCE in available space with work furnished under other Divisions. D` te.---- (_� (3) Equipment Connections: + FRYE 2)PRODUCTS (a)Connections to Liquid-Handling Equipment in Dry Locations: Use liquid-tight flexible conduit. ARCHITECTS a)Where manufacturer's model or series numbers are specified or shown,these indicate generally acceptable types (q) Equipment for Dry Systems in Dry Locations: Use flexible conduit. By: �� required. Furnish products which comply with all requirements,as specified or shown. gr1 30 W.Benchmark Rd.Ste.216 ib)When more than one unit of the same class of equipment is required,provide units produced by a single i)Electrical Metallic Tubing: V�� ,. Avon,CO 81620 manufacturer. (1) Continuous,seamless steel tubing,galvanized or sherardized on exterior,coated on interior with smooth hard 3 TESTS finish of lacquer,varnish or enamel,with steel,set screw or compression type fittings. Provide concrete type fittings where required. a)Furnish test equipment,facilities,and technical personnel required to perform field tests. (2) Use for general purpose feeders and branch circuits. b)At completion of job,check voltage at several points of utilization on the system. Energize all loads installed. iii)Flexible Steel Conduit: 4)CLEANING (1) Single strip,continuous,flexible interlocked double-wrapped steel,hot dip galvanized inside and out forming ��� i1 f Vali. a)Clean all fixtures and equipment at the completion of the project. Wipe clean exposed lighting fixture reflectors and smooth internal wiring channel,with steel,compression type fittings. ;04 trim pieces with a non-abrasive cloth just prior to occupancy. sy �a�lit !,-,77,N )..Cr (2) Use in dry locations only,connections to lighting fixtures in suspended ceilings,connections to equipment �r2 4�m�, 57 y 5)RECORD DRAWINGS installed above suspended ceilings,transformer connections,busway plug in units,and connections to equipment a)Upon completion of the Work,deliver to Architect and up-to-date set of"as-built"record drawings on a reproducible where vibration isolation is required,maximum length of 6 feet. medium including AutoCAD. iv)Liquid Tight Flexible Steel Conduit: 6)DEMOLITION (1) Same as flexible steel conduit except with tough,inert,watertight plastic outer jacket.Fittings shall be cast a)Remove,relocate,and reroute existing electrical equipment to facilitate new construction or remodeling work. malleable iron body and gland nut,cadmium plated with one-piece brass grounding bushings threaded to interior of conduit. Spiral molded vinyl sealing ring between gland nut and bushing and nylon insulated throat. b)Examine the site to observe and note existing conditions prior to submitting a bid. WILDER ENGINEERING LLC (2) Use same as flexible steel conduit in damp or wet locations and at motor connections. c)Schedule demolition in advance. Schedule work to avoid disruption of normal operations. Andrew Wilder PE b)BUILDING WIRE AND CABLE 1170 Blue Sage Drive d)Reconnect circuits serving equipment required to remain in service to other panelboards,motor control centers,or other appropriate distribution equipment. Provide additional panelboards,motor control centers,or other i) Provide wire with a minimum insulating rating of 600 volts,except for wire used in low voltage(below 50 volts)control Steamboat Springs,CO 80487 appropriate distribution equipment where there is insufficient available capacity in remaining existing equipment for or signal systems.The use of teflon(multi-conductor)for low tension systems may be permitted for fire alarm,signal P:970-819-7848 reconnection. and communication systems(voice and data)as approved on shop drawings by engineers and where permitted by local E:andy@wilder-eng.com codes and union practice. e)Remove existing conduit and wire back to panelboard,motor control center,or other distribution source. ii)Conductors f)Where a circuit is interrupted by removal of a device or fixture from that circuit,provide additional conduit and wire issue By Date&Issue Descuptlon By to restore service to the remaining devices and fixtures on that circuit. (1) Electrical grade,annealed copper,and fabricated in accordance with ASTM standards. Minimum size number 12 AWG for branch circuits;number 14 AWG for control wiring. - PERMIT SET - 3.8.16 AW g)Electrical equipment to be removed that is in good working order shall be carefully removed and offered to the Owner. Items rejected by the Owner shall be removed from the project site and properly disposed of. (2) Unless otherwise specified,all wires numbers 10 and smaller shall be solid. (3) All wires number 8 and larger shall be stranded in accordance with ASTM Class B stranding designations. (4) Control wires shall be stranded in accordance with ASTM Class B stranding designations. (5) Cables for low tension systems shall be multi-conductor,16 gauge,color coded and insulated in armored cable assembly,with number of conductors as required. (6) All 600 volt wire and cables unless otherwise specified shall be single conductor suitable for use in wet and dry and locations. iii)Connectors (1) Make connections,splices,taps and joints with solderless devices,mechanically and electrically secure. Protect exposed wires and connecting devices with electrical tape or insulation to provide insulation values not less than on conductor. Scale: iv)Cables(No.8 and Larger): 11x17 NTS (1) Use set screw or compression type connectors,taps and splices specifically designed for the particular Description:SPECIFICATIONS connection. Insulate splice either by taping or by use of"Bakelite"covers designed to fit around splice. v)Branch Circuit Wires(Number 10 and Smaller): Use any of the following types of terminals and connecting devices: (1) Hand Applied:Coiled,tapered,spring wound devices with a conducting corrosion-resistant coating over the Project Name:AUSTRIA HAUS spring steel and a plastic cover and skirt providing full insulation for splice and wired ends. Screw connector on by hand. Project Number 201603 (2) Tool Applied:Steel cap,with conduction and corrosion resistant metallic plating,open at both ends,fitted around the twisted ends of the wire and compressed or crimped by means of a special die designed for the purpose. Specifically fitted plastic or rubber insulating cover wrap over each connector. Sheet No. E-4.0 TOV Stamp Sea c)BOXES iii)Boxes "?J 00 I./C`,k'f� i) Pressed steel,galvanized or cadmium-plated,4 inches minimum octagonal or square with galvanized cover or extension (1) Install electrical boxes as shown on Drawings,and as required for splices,taps,wire pulling,equipment -. 4-4_ ,� ..".'&'' GNAR( •J' / ring as required. connections and compliance with regulatory requirements. V , F ii)Back-to-back outlets in the same wall,or"through-wall"type boxes are not permitted.Provide 12 inch minimum (2) Install electrical boxes to maintain headroom and to present neat mechanical appearance. . ,Q" spacing for outlets shown on opposite sides of a common wall. Provide acoustical potting compound on all outlet (3) Install boxes to preserve fire resistance rating of partitions and other elements;arrange boxes to meet / M 'Z 49009 O; boxes. regulatory requirements. W. m d)WIRING DEVICES (4) Align adjacent wall-mounted outlet boxes for switches,thermostats,and similar devices to each other. / •, ,. --- - i) Switches and Receptacles:Arrow Hart,Hubbell,Leviton,Pass&Seymour,or Slater. (5) Do not use through-walls boxes or install flush mounting boxes back-to-back in walls;provide minimum 6 inch /7 '.� ii)Wall Dimmers:Leviton or Watt Stopper. separation. Provide minimum24 inches separation in acoustic rated walls. ' •IiitD AL �AC .. iii)Occupancy Sensors:Mytech,Novitas,or Watt Stopper. (6) Use stamped steel bridges in bar hanger assemblies to fasten flush mounting outlet box between studs. �jINN ��" iv)Floor Boxes and Fittings: (7) Use adjustable steel channel fasteners for hung ceiling outlet box. (1) Poke through type:Wiremold Legrand. (8) Do not fasten boxes to ceiling support wires. (2) Recessed flush floor box type:Steel City or Wiremold Legrand. (9) Support steel metal boxes independently of conduit. v)Plugstrip:Wiremold. (10) Use gang box where more than one device is mounted together,including floor boxes. Do not use sectional box. vi)Device and cover plate colors shall be as selected by Architect. (11) Plaster Rings: Use for all concealed work;depth of rings as required to reach finished surfaces. AUSTRIA HAUS e)SUPPORTS (12) Coordinate trimming of openings for outlet boxes in partitions to achieve neat,closely-fitting openings. i) Support raceways on accepted types of wall brackets,specialty steel clips,or hangers,ceiling trapeze hangers,or (13) Install knockout closure in unused box opening. PANTRY & BAR malleable iron straps. Plumber's perforated straps are not permitted. Acceptable manufacturers'brackets or hangers iv)Wiring Devices REMODEL are Kindorf,Elcan,Binkley,Multi-Frame,Power-Strut,or Unistrut. Do not suspend raceways or equipment from other 242 E.Meadow Dr. raceways,steam,water,or other piping or ductwork,except as otherwise permitted. Provide independent and secure (1) Install devices plumb,level,and rigidly in place. Vail,CO 81657 support methods. (2) Install switches 2 inches to 8 inches from trim on the strike side. 1 QWf 01 Va! f)PANELBOARDS (3) Install decorative plates on switch,receptacle,and blank outlets in finished areas. Use multi-gang plates for REVIEWED p� �I-, '',' multiple devices. i) Acceptable Manufacturers:Cutler-Hammer/Westinghouse,General Electric,Siemens,or Square D/Groupe Schneider. / PIERCE ii)AIC Rating:Branch panelboards and overcurrent protection devices shall have a minimum short circuit rating of 10,000 (4) Connect wiring devices by wrapping conductor around screw terminal. ry�,A E 1!I P'9 V Ie[r. RMS symmetrical amperes minimum interrupting capacity(120/208V)or 14,000 RMS symmetrical amperes minimum v)Supporting Devices 7 --/ L /4' + FRY E interrupting capacity(277/480V). (1) Fasten hanger rods,conduit clamps,and outlet and junction boxes to building structure using expansion Date:_ iii)AIC Rating:Distribution panelboards and overcurrent protection devices shall have a minimum short circuit rating of anchors,beam clamps,steel ramset fasteners. G-2ARCHITECTS 42,000 RMS symmetrical amperes minimum interrupting capacity(120/208V)or 200,000 RMS symmetrical amperes {� .' 30 W.Benchmark Rd.Ste.216 y p p g p ty Y P (2) Use toggle bolts or hollow wall fasteners in plaster or gypsum board partitions and walls;sheet metal screws or't+,A, G/ Avon,CO 81620 minimum interrupting capacity(277/480V). spring steel bar retainer clips in sheet metal studs. / iv)Enclosures:Corrosion resistant galvanized(zinc finished)sheet steel. Fronts shall be cold rolled steel,finish coated with (3) Do not fasten supports to piping,ductwork,mechanical equipment,or conduit. e.Jo(.!U / ANSI 61 grey enamel over a rust inhibitor. Panel locks shall be keyed alike. (4) Do not use powder-actuated anchors without specific permission. v)Doors:One piece bolt on front with a lockable hinged door over the overcurrent protection devices. (5) Do not drill structural steel members without specific permission. vi)Bus Bars:Silver plated aluminum or copper. Neutral bus shall be full size.Neutral bus shall be 200%rated when (6) Fabricate supports from structural steel or steel channel,rigidly welded or bolted to present a neat appearance. supplied from a double neutral feeder. Provide an equipment ground bus in each panelboard. In addition to the Use hexagon head bolts with spring lock washers under nuts. equipment ground bus,provide an isolated ground bus when supplied from a feeder which includes an isolated grounding conductor. vi)Electrical Identification vii) Overcurrent Protection Devices:Molded case circuit breakers for branch panelboards and 120/208V rated distribution (1) Provide wire markers on each conductor in panelboard gutters,pull boxes,and at load connection. Identify with ii panels,and fusible switch units for 277/480V rated distribution panels. branch circuit for power and lighting circuits,and with control wire number as indicated on equipment ^¢+®`�'n V manufacturer's shop drawings for control wiring. If more than one neutral conductor is present,mark each with Town g)MOTOR STARTERS related circuit numbers. i) Acceptable Manufacturers:Eaton/Cutler-Hammer,General Electric,Siemens,or Square D/Groupe Schneider. (2) Color code all secondary branch circuit and feeder conductors as follows: ii)Manual Motor Starters (a)Four Wire,Three Phase,Grounded Wye System: For 120/208 volt systems,use one black,one red,one blue, P., -+ S _'h;,,,...r. iii)Fractional Horsepower Manual Starter: General-purpose,Class A,manually operated,full-voltage controller for one white(neutral). For 277/480 volt systems,use one brown,one orange,one yellow and one gray(neutral). WILDER ENGINEERING LLC fractional horsepower induction motors,with thermal overload unit,and toggle operator. (3) Use wire with insulation of required color. For sizes of wire,which may not be available in specified colors use Andrew Wilder PE iv)Voltage,Rating and Thermal Element:As required by motor controller. self-adhesive wrap around,markers of solid colors to color code conductors. 1170 Blue Sage Drive v)Enclosure: NEMA ICS 6;Type 1. (4) Color code conductors at accessible locations. Steamboat Springs,CO 80487 h)PULL LINE (5) Pull Rope Marking:Affix label identifying termination point at each end of pull rope. P:970-819-7848 i) 1/8 inch diameter braided yellow polypropylene. vii) Disconnect Switches E:andy@wilder-eng.com (1) Install disconnect switches shown mounted on walls at+4'-6"to centerline of switch. 3)PART 3 EXECUTION (2) Install disconnect switches shown on or adjacent to equipment on field fabricated galvanized steel frames. issue By Date&issue Description By vii) INSTALLATION viii)Panelboards — PERMIT SET — 3.8.16 AW i) Conduit (1) Provide filler plates for unused spaces in panelboards. (1) Install conduit in accordance with NECA"Standard of Installation". (2) Provide typed circuit directory in plastic holder for each branch circuit panelboard. (2) Do not combine individual homeruns into common conduit. ix)Motor Starters (3) Do not support conduit with wire or perforated pipe straps. Remove wire used for temporary supports. (1) Install motor control equipment in accordance with manufacturer's instructions. (4) Arrange conduit to maintain headroom and present neat appearance. (2) Select and install heater elements in motor starters to match installed motor characteristics. (5) Use conduit hubs to fasten conduit to cast boxes. . x)Pull Line: Provide in each empty conduit except sleeves and nipples;leave 8 inches of slack at each outlet. (6) Provide insulated equipment ground conductor in flexible conduit. xi)Firestopping: Provide firestopping around all pipes,conduits,sleeves,etc.,which pass through rated walls,partitions and (7) Install conduit to preserve fire resistance rating of partitions and other elements. floors. (8) Do not attach conduit to ceiling support wires. END OF SECTION ii)Building Wire and Cable scale: (1) Use conductor not smaller than 12 AWG for power and lighting circuits. 11u17 NTS (2) Neatly train and lace wiring inside boxes,equipment,and panelboards. Description:SPECIFICATIONS (3) Make splices,taps,and terminations to carry full ampacity of conductors with no perceptible temperature rise. (4) Use hardened and tempered steel,tin-plated or stainless steel Belleville washer with slightly larger tin-plated mild steel flat washer for aluminum lugs. Project Name:AUSTRIA HAUS (5) Use insulated spring wire connectors with plastic caps for copper conductor splices and taps,8 AWG and smaller. Project Number:201603 Sheet Ni E-4.1