Loading...
HomeMy WebLinkAboutB16-0210.001 plans approved.pdf Al 6 , f of it t i ,„„ „,„ ,,. iFn7npy 2 3 T T 2Ell 5 PROJECT INFORMATION N lE EXTERIOR CORRIDOR INTERIOR NOTES: >£ ' /. ' ill ADDRESS/LOCATION: 605 NORTH FRONTAGE ROAD WEST ' r'' ' ' ) '''' *: • �. .. ...M*i*Af�.*i�. *i.'' aiti}«* iil�'}i?i a*ios*tie*+s'i*�*avy�t*4i** 'a:l�i*yit.. ) +. Fo UNITS 21A & 31A T +:.�0 °4, �`�- 4'+'At ' t , :z;.".Q ¢ !:t:Z-Vt :t.x.x.;. . .t t4A„m„ • . ', t+*`, VAIL, COLORADO ►; (E) CORRIDOR/RESIDENCE WALL & FRONT a ENTRANCE DOOR TO REMAIN, ;+ .-' MAINTAIN (E) FIRE RATING, TYP. OCCUPANCY CLASS: NO CHANGE - R-2 14 2 ALL NEW BATH FIXTURES & FINISHES IN BATH, if BUILDING TYPE: NO CHANGE TO EXG (TYPE Ill-B KITCHEN °- i, � KITCHEN & LAUNDRY. MAINTAIN FIRE RATING AS ) al BED 4 ` , . A_ II T NEEDED AT FLOOR SYSTEM BELOW 2ND LEVEL UNIT SIZE: UNIT 21A = 1,300 SF.(E) 3 ALL NEW WALL, CEILING & FLOOR FINISHES. REMOVE ° UNIT 31A = 1.218 S.F. (E) I. (E) NON-BEARING INTERIOR WALLS AS NEEDED UNIT 31A = 82 S.F ADDITIONAL 11 ) ' TOTAL = 2,600 S.F. BATH 3 4 (E) WINDOW TO REMAIN SCOPE OF WORK: DEMO EXG. INTERIOR FINISHES INCLUDING BATH & KITCHEN FINISHES. I " ° ~ - INSTALL NEW FIXTURES & FINISHES IN ROOMS. v /' `� DESIGN INSTALL NEW CONNECTING STAIR BETWEEN RESIDENTIAL UNITS. l'-'L , ,. INSTALL NEW EXTERIOR WINDOWS/DOORS 5 NEW IINDOW IN (E) OPENING e PO Box 9190 FIRE RATINGS: - Avon, Colorado 81620 WALL /RES. TO RES. = Yz HOUR (PER 708.3) WALL / CORRIDOR TO RES. = 12 HOUR (PER TABLE 1020.1) 6 REMOVE (E) FIREPLACE. BLOCK FLUE AS NEEDED WALL/ RES. TO STAIR = 1 HOUR (PER 1023.2) 10 FLOOR / RES. TO RES. = r2 HOUR (PER 711.2.4.3) / Imayer@lksmdesign.com '_ 7 INSTALL NEW STAIR BETWEEN 2ND & 3RD FLOOR. RE: DETAIL ON SHEET A3.1 11 5- PROVIDE NEW STRUCTURE FOR OPENING RE: ENG. 8 PROVIDE A 36" GUARD RAIL AT THE UPPER LEVEL )111 3 FO THE STAIR DECK LIVING ROOM LAUNDRY MEDIA ROOM PA Ell 9 FILL IN BALCONY OPENING W/ WALL & SIDING TO CF-Th. j ARCHITECT: GENERAL CONTRACTOR: OWNER: MATCH (E). INSTALL NEW WINDOW. SIZE TO MATCH LKSM DESIGN, PC TONY DURAN JACQUES PAYEN MARQUEZRiR 1 WINDOW BELOW. ALIGN W/ (E) PO BOX 9195 AVON, COLORADO JPi•AYENARCH.COM , / 12 10 INSTALL NEW DOOR & TRANSOM TO MATCH (E) co il-i 81620 011 521 55 5506 4030 COLOR/STYLE. SIZE SHALL MATCH (E). 970.376.6623 970.531.8985 ____ LMAYER(LKSMDESIGN.COM TONYDURAN56@YAHOO.CO�9 l :` -------- 11 INSTALL NEW WINDOW TO MATCH (E) COLOR/STYLE. CONTACT: LEAH KS MAYER CONTACT: TONY DURAN f i SIZE SHALL MATCH (E). 12 REMOVE (E) WINDOW & EXTERIOR WALL, PROVIDE NEWH,r . ._....... _ 9 f r ,, 1 1. DO NOT SCALE DRAWINGS 4 NN. 13 INSTALL NEW FIREPLACE WITH DIRECT VENT FLUE, GENERAL NOTES 6 3 5 13 5 PROVIDE FLUE PER MANUFACTURERS 2. THE GENERAL CONTRACTOR FOR THIS PROJECT SHALL COORDINATE ALL WORK WITH -- RECOMMENDATIONS - SUB-CONTRACTORS. G.C. SHALL ORDER ALL MATERIALS UNLESS OTHERWISE NOTED. ALL SUB-CONTRACTORS SHALL VERIFY ALL DIMENSIONS & EXISTING CONDITIONS ON THE JOB 14 INSTALL NEW WINDOWS TO MATCH (E) SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY OWNER OR 4 COLOR/STYLE. HEAD SHALL MATH (E) SILL © 40". ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. tit f� 3. ALL NEW WALLS SHALL ALIGN WITH ADJACENT EXISTING SURFACES. ALL NEW WALLS P RO P E D FLOOR F PLAN UNIT 31A WHICH REQUIRE PATCHING SHALL MATCH EXISTING FINISH AND TEXTURE. PAINT ENTIRE A2.1 1/4"= 1'-0" SHADED AREA INDICATES NEW WALLS W WALL IF ANY PATCHING HAS BEEN PERFORMED. 4. ALL NEW WALLS SHALL MATCH EXG, CONSTRUCTION. PATCHING OF EXISTING RATED WALLS :` ti{� SHADED AREA INDICATES CORRIDOR WALLS (PARTY WALL) SHALL MAINTAIN THE EXISTING WALL CONSTRUCTION. CEMENTITIOUS BACKER '� BOARD SHALL BE USED IN ALL WET AREAS. PROVIDE HORIZONTAL BRACING AS PER < 0 N. MANUFACTURER'S RECOMMENDATIONS ON SPANS OVER 8'-O" 5. MAINTAIN EXISTING FIRE RESISTANT WALL CONSTRUCTION FROM RES. UNITS TO RES. UNIT V--I PROVIDE FIRE-STOPPING AT ALL NEW PENETRATIONS IN FOR RATED CONSTRUCTION. Q 6. ALL EXISTING FIREPROOFING &/OR FIRE-RATED WALL SYSTEMS SHALL REMAIN INTACT. «~ 0 Z NI ANY FIREPROOFING DISTURBED DURING CONSTRUCTION MUST BE REPLACED PER ORIGINAL THICKNESS AND SPECIFICATION, G.C. SHALL COORDINATE ALL REPAIRED FIREPROOFING. - D u") 0 J 2 3 U T � 5 V) F, et ---I 7. DUE TO UNCERTAINTY OF THE EXISTING STRUCTURAL CONDITIONS, FIELD EXAMINATION �-' AND COORDINATION IS REQUIRED PRIOR TO CONSTRUCTION START. '` 'I T / T EXTERIOR CORRIDOR ° i O T 8. NON-COMBUSTIBLE FRAMING SHALL BE USED THROUGHOUT. NON-STRUCTURAL FRAMING A 1 ; MAY BE COMBUSTIBLE ONLY WITH THE APPROVAL OF THE BUILDING OFFICIAL4. 1.4 ,. . .. t , rlio'0 *11-utr. *4*--N,V.I.4,...410 V atom '" fk s 9. ANY FAN/DUCT WORK LOCATED IN 1-HOUR WALL CONSTRUCTION SHALL HAVE A 1-HOUR _ rr RATED DAMPER. - ■ 1 1 1 S GO to �; �. ._ ._�. .r 10, ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR. M. BATH M. CLOS. ;I ` BED 3 11. THE G.C. SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND REQUIRED -- APPROVALS, THIS PROJECT IS GOVERNED BY THE 2015 INTERNATIONAL BUILDING CODE. 11 I `� CODE COMPLIANCE IS MANDATORY, THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT I t,, T T WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING ALL LOCAL AND 4f °° BATH 2 REGIONAL CODES. j 4 ;4-'1;4-'14; 12. THE TOWN OF VAIL IS THE LOCAL JURISDICTION. EXTERIOR WORK SHALL BE APPROVED 0 pis, t E BY THE TOWN OF VAIL DESIGN REVIEW BOARD AS NEEDED. r: / UP . ' 13. THE OWNER SHALL PROVIDE HOA APPROVAL FOR THIS SCOPE OF WORK, ;, z >'2 -� :- v� :8(1),,i f m�. 4g1 " I . 10 \ / AA°41* *. rn 4r_ ,/, ,,,,„.. , 1. RESIDENTIAL ENTRY DOORS ARE NOT PART OF THIS SCOPE OF WORK. IF WORK IS 11 PERFORMED ON THE FRONT ENTRY DOORS, A Y HOUR FIRE RATING DOOR MUST BE - '411414 PROVIDED WITH CODE COMPLIANT HARDWARE. I,� ° 11111 111 ISSUED: DATE: 2. INTERIOR DOORS SHALL BE REPLACED IN THIS SCOPE OF WORK. WOOD DOORS CAN BE DECK M. BED BATH 1 Li BED 1 BED 2 r FOR PERMIT 05.23.1 :INSTALLED. II ' _11.441,, 3. NEW WINDOWS SHALL HAVEA U-VALUE OR ER .:\:1. REV. PERMIT 6.8.16 , , U L E OF .32 BETTER. 4. ALL NEW EXTERIOR WINDOWS AND DOORS SHALL MATCH EXISTING IN FINISH AND COLOR il I 1 li , l l-- � I 't i, k 4 * iii, ,:'111,11:0. \ s':....,, I -� k ' ‘‘' t 1 m DI r" , FIRESTOPPING NOTES r 11. A- i 1. PROVIDE FIRESTOPPING AT ALL PENETRATIONS IN RATED FLOOR AND WALL ASSEMBLIES. REQUIRED FIRE RATINGS ARE LISTED IN PROJECT INFORMATION NOTES. DRAWN BY: LKSM 2. ACTUAL (E) WALL AND FLOOR SYSTEMS ARE UNKNOWN AT TIME OF PERMIT. THE G.C. SHALL PERFORM EXPLORATORY DEMOLITION AT THE BEGINNING OF THE PROJECT TO COPYRIGHT 2016 LKSM Design,P.C. DETERMINE THE ACTUAL CONSTRUCTION SYSTEMS. THE ARCHITECT SHALL PROVIDE ADDITIONAL FIRESTOPPING DETAILS AS NEEDED DURING CONSTRUCTION. \\6- - -5 2 5 4 TITLE: 3. APPROVED FIRESTOPPING PRODUCT INCLUDES 3M FIRE CAULK CP 25 WB AND SHOULD BE I I GENERAL INFO& INSTALLED PER MANUFACTURER INSTRUCTIONS AND UL DETAILS. - '' PROPOSED FLOOR PLANS A2 . 1 ' 1 PROPOSED FLOOR PLAN - UNIT 21A A2,1 1/4"= 1'-0" SCALE: it i PROJECT NO.: 15-25