HomeMy WebLinkAboutFraming Notes.pdfFRAMING NOTES ~ , __ _ 1/4" = 1'-0" NOTES: 1. WALL FRAMING PREVIOUSLY LOCATED AND POSSIBLY SUPPORTING THE MEMBER ABOVE SHALL BE RETURNED TO PRE-WATER DAMAGE LOCATION AND CONFIGURATION. IT IS THE CONTRACTORS RESPONSIBILITY TO RETURN THIS FRAMING TO EXACTLY THE WAY IT WAS BEFORE DEMO. 2. MINIMUM SUPPORT COLUMN SHALL BE (3)-3X6 AT CORNER INFILL AND BE OF DOUGLAS-FIR No.2 GRADE OR BETTER. 3. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2x6 DOUGLAS-FIR STUD GRADE STUDS OR BETTER SPACED AT 16" o.c., TYPICAL, UNLESS NOTED OTHERWISE. ALL WALLS SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR AND FLOOR TO ROOF. 4. TOP Af\!D BOTTOM PLATES SHALL BE OF DOUGLAS FIR-LARCH OR HEM-FIR #2 OR BETTER. PLATES IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE OF PRESSURE TREATED HEM-FIR #2. PRESERVATIVE TREATED LUMBER REQUIRES ALL CONNECTIONS AND NAILING BE GALVANIZED PER CODE. 5. TIE NEW TOP PLATE SECTIONS TO OLD WITH SIMPSON STA2122 STRAPS AND lOD X 11/2" NAILING, TYP. 6. WALL SHEATHING SHALL BE 7/16" PLYWOOD OR OSB SHEATHING RATED 24/16EXPOSURE1 OR BETTER NAILED WITH lOd GUN NAILS (0.131"x3") AT 4" o.c. MIN AROUND ALL OPENINGS, AND AT PANEL EDGES. BLOCK ALL PANEL EDGES. 7. FOR ALL SOLID OR BUILT-UP COLUMNS BEARING THROUGH FLOOR JOIST SPACES, PROVIDE BLOCKING IN JOIST SPACE WITH CROSS SECTIONAL AREA TO MATCH COLUMN ABOVE. (ij) I™ FRAMING NOTES I,_. 770 POTATO PATCH CONDO ~:1~~~11Jf--+-l---il--------+l--+-l--1l1~ RE~~:;;~~~::IS''--5 ---i1.251-~3.1 .,,:.:.::.::::::... ti 0 06/07/2016 ISSUEOFORCONSTRUCTION MSV MSV 3/4" =1'-Q" EDWARDS, OOIJ..632 Ji NO. DATE DESCRIPTION SY CHK - JOBNO. 16005 STRUCTURAL ENGINEERING -CIVIL ENGINEERING -ARCHITECTURAL DRAFTING -3D MODELING