HomeMy WebLinkAboutE16-0210 plans approved.pdf Town of Vail N - P { : Dnp Y PANEL EMCC-EM POWER ONLY GENERATOR SIZING 1 i IN'n of Vail N PROJECT 15,58 PARKING VOLTAGE SOH REVIEWED FOR CODE PROTECT N'.15058 VOLTAGE. 5044 0V.3P.4W BONDING JUMPER MOUNTNG SURFACE MANS 600A MLO •(no Cu G13/4'C TYPE.EXSTING A1C' 14 K a 0/5 TO TELEPHIX4E N OESCRPTDN A PHASE C FUSE P CR CR P FUSE A 8MASE C DESCRETON ivl P L I A N C E �- / 71�E CONCRETE-ENCASED SUPPLYFANI 4848 35 3 1 2 3 35 4848 FE /� e m ELECTRODE 4848 4848 5 6 4848 4848 Date:V. -___ _- _- - _- _ _ --. 7 d SUPPLY FAN 1A 5540 40 3 7 B 3 40 5540 EXHAUST FANS 55.7,8 40 N m o§ INCOMING GAS SERVICE PIPE • - 5540 5540 II 12 5540 5580 - S V , _ WL) � o SUPPLY FAN 4848 36 _3 13 14 3 35 4848 EXHAUST FANS 9.10,11.12 ✓ ,!,1°-,71ETa pp 4846 _ 15 18 4848 C g'y Q,U PIINPING WATER SERVICE --- I I -SUPPLY FANS 4848 4848 17 18 35 3 19 20 3 40 5540 -4818 EXHAUST FAN51314.15.16.1iCoda - _- - _-- -- - .Q v > 4848 21 22 5540 • CloC m¢m o 4) ♦ ♦ 4848 23 24 5540 -p1 BO rn c ei WATER METER SUPPLY FAN 5540 40 3 25 26 3 35 4848 EXHAUST FANS 18.19,2021,2 c Q 2 5540 27 28 4848 LLl y J n.S BUILDING STEEL 5540 29 30 4848 TO W$m p 52 (313/4"F10'DRIVEN SUPPLY FAN S 4848 35 3 31 32 3 35 4848 EF-22,232425,26. 7 I V— �GROUND RODS IF 4848 33 34 4848 .) u= REQUIRED BY 0 335 .• 4848 30 0 1846 O 7 LOCAL AHJ 41'. 'r v 0 0 _ 39 -40 0 0 PANEL PANEL ` Q m 41 42 RESTAURANT COFFEE Q o ETSERVICE GROUNDING DLOAD CALCULATION SUMMARY EMERGENCY POWER REPRESENTS 470 KW/957 KW OR 49%OF DISTRIBUTED POWER v HIGHEST EMERGENCY POWER DEMAND THEN CAN BE ESTMATED AS 49%-1.25 NEC DEMAND NO SCALECALCULATED POWER FACTOR •62%DEMAND FACTOR A62%DEMAND FACTOR HAS BEEN APPLE D TO THE CALCULATIONS BELOW NOTE PROVIDE#3/0CU CONDUCTORS TO AL ROU . G ELECTRODES. 0.85 470 KW-CALCULATED LOAD OF EMCC 8 957 KW.CALCULATED LOAD OF MDC .µ>� CONNEC1E0 LOAD CONNECTED AAPS DEMANDLOAD DEMAND AMPS �.�Q h{ �'Fy CONFIRM BUILDING GROUNDING LIGHBNG 66314 104 66893 80 RECEPTACLES 15820 19 6004 10 SYSTEM IS UP TO DATE AND TO PANEL PANEL afarA '' S CURRENT CODES AS SHOWN PER MECHANICAL 466349 561 291712 351 SP-3 SP-4 ��;'.' E7• THIS DETAIL. KITCHEN 0 0 0 0 r1 f `$ TOTAL 684441 } 150/3 /l S 100/3 50/2 4U. .. PANEL30 KVA D./3 KVA EM-2 REPLACE EXISTING PANEL EM-2 AS SCHEDULED.MOVE EXISTING BUS/MA AHU-1.BOILER A BIMB,PUMPS 75 0 CAR 0/26BV 3P 4W 63 8 11 4CIRCUITS AND BOILER CONTROL CHARGERS®GARAGE �0208V 3P 4W CIRCUITS TO PANELS EM-1 8 EMCCA-120V AILy WEST P2 OFFICES PER PANEL SCHEDULES SHEET El.I PANEL PANEL PANE P- EL PANEL PANEL PANEL PANEL PANEL PANEL GEN EMCCA PP - -1 SP1 HP1 LP1 UC-1 XFMR LVL 2 LP2 AT EXISTING BOILER NSA 8 N48.PUMPS N3 8 4 PROVIDE 30/3 SERVICE DISCONNECT 802 ("1, SWITCHES FOR EQUIPMENT AS REQUIRED 100/3 30/3 BY CODE.PROVIDE IDENTIFICATION OF 3 NB CU,98 I� DISCONNECTS WITH PLAQUES TO READ CU)3/4"C 10073 1Y 7 LO 'BOILER IMA".MOILER#413"ETC.LOCATE LCD DISCONNECTS IN FIELD REVIEW WITH <14K Al OWNER PRIOR TO POUGHIN. ELECTRICAL CONTRACTOR TO PROVIDE MARK UP OF THIS o Ill I I r ELECTRICAL ONE-LINE DIAGRAM AS FOLLOWS: I 1 1 TM ALL PANELS AND IDENTIFY LOCATION WITHIN ^ O STRUCTURE. C\ 25 KVA -ADO ANY PANELS NOT SHOWN AND INDICATE WHERE 480Y- PANELS ARE FED FROM AND IDENTIFY PANEL LOCATION. 120 W 208V 17 3 -REVIEW WITH ENGINEER THE MARK UP AND WALK THROUGH TO CONFIRM EACH PANEL. NEW WORK IS CLOUDED REST IS EXISTING TO REMAIN UNLESS NOTED PANEL PANEL O EMCC \211-.-- MDP LOCATE ENGINE-GENERATOR - - `•'\ 0 ANNUNCIATOR IN BUS SUPERVISORS 70/2 200 OFFICE.CONNECT TOED-1. `v^l, LU z J U EMCCA-38 CO - 200/T PANEL PANEL PANEL PANEL 70/3 ` _ LP-3 HP-1 MMC2 LP-4 in ' 1 ANNUN O/1T-- N 1N�r�1 ' ' I 200 14K AIC - \ - 1 1 '•LLL • 2D`,!3' Q V 8i THESE LOADS FED FROM PANEL GEN -d0/3 1 .176 AICA `v � Nol EG 1 EGCH 2540/500 MCM CU)4'C]-0 200T HEATER CHARGER 450 KW.277/480 3P 4W STANDBY DIESEL GENERATOR.FOR AN ALTITUDE OF 13150E7.GENERATOR /-1 11-- TS TO INCLUDE WEATHERPROOF 800/3 C 2[(4 N500 MCM CU)4•C] ENCLOSURE.DAY TANK,CRITICAL 800/3 SILENCER EXHAUST MUFFLER,AND 2((4 N500 MCM CU)4-C1 VIBRATION ISOLATORS. AEC PROJECT 8: 15058 • GENERATOR NOTES MOLY CROSS METER#93458 HIGHEST DEMAND JANUARY 2015 DATE: ISSUE. 290 KW-350 AMPS 1. CONTRACTOR TO PROVIDE CONCRETE PAD TO MEET `19K AIC _ _ - - - - - _ _ _ _ _ 07/16I15 PROGRESS GENERATOR MANUFACTURERS REQUIREMENTS. 08/11/15 FINAL REVIEW MANUFACTURER TO INCLUDE PAD INFORMATION ON THEIR (3)800A 55(3)800A (3)200A (3)200A (31200A (31200A 08/19/15 PERMIT SHOP DRAWINGS.INITIAL ESTIMATE FOR THE PAD,WITH A 8"LIP FUSES FUSES ON ALL SIDES,981N 2001 X 12-DEPTH USING CONCRETE T 99,5000 AIC 78500 Aid I 800/3 800/3 20200 3R 200/3 R 200/3 20 R 1 10/6/16 PERMIT UPDATE DENSITY OF 145 LBS/F3. I r C.-EXISTING 1 �, I 1 + , ` + I 2. WITH SHOP DRAWINGS FROM GENERATOR MANUFACTURER STAKE 0 OUT NEW GENERATOR PAD TO REPLACE EXISTING GENERATOR ILITY I I c...By cn.a.J By (SAME LOCATION).REVIEW HEIGHT,FUELING ARRANGEMENTS, - - - - _ - - - - _ _ _ SOH �C. WHERE THE EXHAUST IS TERMINATED.IF TREES NEED TO BE T"•NSFORMER MAIN DISTRIBUTION CENTER"MDC" REMOVED OR TRIMMED.ACCESS DOORS ARE ALL CLEAR,ETC. ••P MOUNTED PROVIDE SITE MEETING WITH OWNER AND ELECTRICAL ENGINEER 2000A,277/480V,3P,4W TO REVIEW TWO CONFIGURATIONS OF THE GENERATOR,ONE WITH \\11 �n THE GENERATOR ORIENTED EAST WESCAL THE GENERATOR ORIENTED T AND THE SECOND WITH 42kAlc-ThONE-LINE1101 �' C \\J(/ DIAGRAM �� OCTr.), ELECTRICAL ONE-LINE DIAGRAM (JV06 2016 NO SCALE I NOTE PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED AT ONE-LINE,NOTED AS'AIC AVAILABLE'.SERIES RATED COMBINATION SCALE:NONE ACCEPTABLE.SUBMIT MANUFACTURERS SERIES RATINGS WITH SHOP DRAWING REVIEW. "L. OF VAIL E 1 .0 I of 3 �e IIDN 4490985 6Y46PMG0 9085 K_ • MAIN DISTRIBUTION PANEL-MDP-ORIGINAL MAIN DISTRIBUTION CENTER-MDC-HIGHEST DEMAND CALC MAIN DISTRIBUTION CENTER-MDC-CALCULATED PROJECT VAL VLLAGE PARH.IN.:: ENGINEER. SOH PROJECT VAL VLLAGE PARKNG ENGINEER. CTL PROJECT'.VAL VLLAGE PARK',NG ENGINEER. SOH PROJECT It 15058 VOLTAGE. 277!1605.3P.4W PROJECTt 15058 VOLTAGE 2777480V.3P,4W PROJECT l:15058 VOLTAGE 277/4800.3P.4W MOUNT*:SURFACE MANS: 6000 MLO MOUNT*:SURFACE MANS: 20001 MLO MOUNTING.SURFACE MANS: 2000A MLO TWO.EXIT* AC. 14 K ME EXSTNG AC: 14 K TYPE EXISTING AC: 14 K PHASE1 PHASE PHASE _ _ PHASE PHASE PHASE DESCRIPTOR A B C FUSEP CR GRP FUSE A B C DESCRPTKN DESCRPTDN A B C FUSEI P CR CR P FUSE A B C DESCRPTION DESCRPTION A B C FUSE P CR CR P FUSE A 8 C DESCRIPTION PANEL SPI 17780 200 3 1 12 3 100 ,8383 LEVEL2 TRANSFORMER EMCC VIA ATS 0 1 800 3 ',1 2 3 20 0 PANELMMC2 EMCC VIA ATS 189494 800 3 11 2 3 200 28254 PANELMMC2 • 17180 : 3 4 6383 0 3 " 17780 5 B 6383 • - 0 1&]484 - 3 4 28254 D '5 6 � 0 169194 'S 6 28254 • PANEL 119.1 0 200 3 7 8 3 100 11000 LEVEL 3 TRANSFORMER PANELLP3 0 200 3 7 _8 3 200 0 PANELLPI PANELLP3 42077 200 3 .7 8 -3 200 219707 PANEL LPI N MOVED TO MDC 0 9 10 11000 0 9 10 0 42171 9 10 0767 yFi 0 11 12 11000 0 11 -12 0 42317 11 12 29767 • TTT b m PANEL LPI 7991 200 3 13 •14 3 60 0 UNDENTFEC PANEL Ni. 14 3 600/3 0 MDC* m 7991 15 16 0 1 0 200 3 13 PANEL HIP-1 27205 200 3 13 •14 3 600 51818 MOP -0 7991 17 18 0 0 ..15 16 0 27210 15 16 51816 ORONAL MOP m P 9 y m ° 0 17 16 0 27200 17 1B 51818 • SPARE 0 200 3 19 20 3 X30 0 SPARE HIGHEST DEWING 98887 3 19 20 b 0 19 20 0 .92'c So c • 0 I21 22 0 JANUARY2015 96667 21 71 0 0 21 22 0 U ';'°'°-2E 0 n �N 0 PER IJILm NPO 96667 23 24 0 0 _ n 24 0 W y m 8 O 25 28 3 30 0 SPARE 0 25 28 0 0 25 T. - 0 .0 2;Q v 0 • 27 28 0 0 27 _28 0 0 27 28 0 a9 f i10 29 30 0 - _ 0 29 30 0 • 0 _ '29 30 D O 31 32 3 400 8664 PANEL UC.1 0 31 32 0 0 - 31 32 0 •C 45 Q E 0 0 33 34 8664 VA 73 KVA TRANSFORMER 0 33 34 0 0 33 34 0 - Wow07 to m R '0 35 38 ,B894 • 0 75 36 0 0 - '35 36 - 0 C Wv O 37 38 - 0 G 37 -38 0 0 137 39 0 W T�' L _. 0 39 i0 0 0 39 40 - 00 _ 139 40 0 \111E W 5 e-5 .__0 41 42 0 p Al 42 _ 0 0 •41 42 0 > § 1''1 I LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY 1 07 2 , CALCULATED POWER FACTOR: - E:7 /4O CALCULATED POWER FACTOR CALCULATED POWER FACTOR: 7. m 0 097 1,00 090 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTS AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED MAPS DEMAND LOAD DEMAND AMPS Q 5 L924/I/NG 44073 53 55091 66 HIGHEST DEMAND 290000 34 362500 436 LIGHTING 248749 299 310936 374 RECEPTACLES 74082 69 42041 51 RECEPTACLES 0 0 0 RECEPTACLES 181902 219 95951 115 MECHANICAL 24800 30 28925 35 MECHANCAL 0 0 0 MECHANICAL 6626809 797 0520059 797 .... KITCHEN 12505 i5 8125 10 KITCHEN 0 0 0 KITCHEN ,2500 15 8125 10 9. 'Sn'- - TOTAL 155455 18] 134182 161 TOTAL 290000 34 362500 436 TOTAL 1105832 1331 1077693 1297 :�O•G H'�`-•},- • ;J. .4ffsrA.._'9 PANEL EMCC-MCC AT BOILER ROOM-SECT 2 PANEL EMCC-MCC AT BOILER ROOM-SECT 1 PANEL MCC2-MCC AT BOILER ROOM =Is /7, PROJECT.VAL VLLAGE PARKING ENGINEER CTL PROJECT.MAMA VI LAAGE PARK* ENGINEER CTL PROJECT.VAL AIME PARKING ENGINEER: CTL '$ . PROJECT It 15058 VOLTAGE. 277/4805,3P.4W PROJECT:15058 VOLTAGE 277/4055,3P.4W PROJECTS:15058 VOLTAGE 277/4805.3P 4W 1 TATE: ( MUN OTING:SURFACE MANS 600UNS WML 1 MLO MOTING'SURFACE MANS O MOUNTING:SURFACE MANS- 6006 MLC '- '37/p�A�_c''M E:EXSNG TAIC: 14 K TYPE-MUSING AC' 14 K TYPE.EX6TNG AC' 14 K _ PHASE PHASE PHASE PHASE PHASE PHASE DESCRIPTION A B C FUSE P CR CIA P FUSE A B -C DESCRIPTION DESCRPTICN A B C FUSE P CR CR P FUSE A B C DESCRIPTION DESCRIPTOR A 8 C FUSE P CR CR P FUSE A B C DESCRIPTION EF-2735.29,30 4849 35 3 1 2 3 100 14596 ELEVATORI4 SUPPLY FAN: 4648 35 3 1 2 3 35 4848 P.O SNONRAELT PUMP 5310 60 3 1 2 3 60 8310 SNOVJAELT PUMP 4848 3 4 14598 40HP 4848 3 4 4848 8310 3 4 8310 • 4840 5 6 14598 •• 4848 5 6 4846 8310 5 6 8310 • EF-31.32.33.34 4848 35 3 7 8 3 100 14598 ELEVATOR/2 SUPPLY FAN IA 5540 40 3 .7 6 3 40 3340 - EXHAUST FANS 5.6.7.8 BOLERI4 PUMP 1682 12 3 7 B 3 12 1662 SOLER14 4848 9 10 14598 4014 5540 9 10 5540 • -- 1662 9 10 1662 O • 4848 11 12 14598 " • 5540 11 12 5540 1862 11 12 1882 • UNIDENTIFIED 484835 3 13 14 3 100 11080 ELEVATORI3 SUPPLY FAN 4848 35 3 13 14 3 35 4848 EXHAUST FANS 9,1011,12 SOLERN PUMP 893 5 3 13 14 3 10 1365 BOILER/2 -4848 15 16 11080 30 HP 4848 15 16 4848 _ " 693 15 16 1385 • 4848 17 38 11080 494 05 8 117 1B 4848 •• - 593 17 18 13 • Al PANEL EMCCA 277/4835 13688 70 3 19 20 3 /00 50479 PANEL EM-1 SUPPLY FAN 4848 35 3 19 23 3 40 5540 EXHAUST FANS 13,14.1516.17 SOLER/3 1682 12 3 19 23 3 12 1662 BOLERPI • 13686 21 22 50479 4848 21 22 5540 • J 1862 21 22 1482• (.9 n r.,13688 23 24 50179 - • 4948 23 24 5640 1662 23 24 1683 • v 2 PANELEMCCA I2FABV 7907 169 3 25 28 0 SUPPLY FAN 4 5540 40 3 '25 26 3 36 4848 EXHAUST FANS 18,1920,21,Z D 25 26 3 12 1862 SPRNKLERARCOMP ILiI� • 7907 27 28 0 5540 27 28 4848 - 0 27 20 1662 • 7907 ' 29 30 0 5540 29 30 4848 • - 0 - 29 30 1662 - L BOLERB-2 1662 12 3 31 32 0 SUPPLY FAN 4848 36 3 31 32 3 35 4848 EF.22A.2435,26. 0 31 32 3 4 554 TERMINAL CRC PUMP 04 0CO • ,Bfi2 _ 33 34 0 4948 33 34 4818 - 0 33 34 554 E 2 O 1662 36 0 4818 35 36 4848 • 0 35 38 STM - 0 37 38 0 0 37 38 0 0 37 38 3 5 693 TERMINAL CRC PUMP/5 / 0 39 40 0 0 39 40 0 0 39 40 693 \ LLJ < 0 41 42 0 0 41 42 693 • LOAD CALCULATION SUMMARY LOAD CALCULATOR SUMMARY EMCC SGTACt OND SECTION LOADS ARE I4CLU0E0 LATHE CALCULATIONS BELOW LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR. CALCULATED POWER FACTOR O 069 CALCULATED POWER FACTOR 0 69065 a. w < J CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMP6 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD PEMANG/AMPS O LOHTM• 66314 104 107593 130 LIGHT* 06314 104 107693 130 COMING 0 0 0 0 Z '` RECEPTACLES 15821 19 1291C 16 RECEPTACLES 15820 19 12910 16 RECEPTACLES 0 0 0 0 V MECHANCAL 28529 341 336213 371 MECHANCAL 466349 561 470504 566 MECHANICAL 84762 102 939945 110 KITCHEN 0 0 0 0 KITCHEN 0 0 0 0 KITCHEN 0 0 0 0 ' I I J TOTAL 385663 464 429016 516 TOTAL 560483 684 59,306 712 TOTAL 84762 l 80995 110 I••••+ PANEL EMCCA PANEL EM2 PANEL EM1 Q PROJECT TOV GENERATOR VLLAGE PARK* ENGINEER SOH PROJECT VAL VLLAGE PARKING ENGINEER SOH PROJECT VAL VLLAGE AOE PARK* ENGINEER: SOH J PROJECT t.15058 VOLTAGE. 120/208V,IP,3W PROJECT*.11083 VOLTAGE. 2771460/,3P,4W PROJECT M.11063 VOLTAGE. 277/4110V.3P.4W NOUN-MG SURFACE MANS 12551408 MOU44TNG SURFACE MANS' 103A MLO MOUN1 N0 SURFACE TYPE SO D ROOD OR EQUAL AC 10K TYPE SQUARE D NF OR EQUAL AC: 14 K A PNS 2050 MLO PHASE PHASE - - PHASE 1 • PHASE TYPE EASING AC. i4K ik OESCRPTON A B BKS P CR CR P-8KR A B DESCRIPTION DESCRIPTION A B C 8KR P CR CR ,P 'BUR A B C DESCRPTDN - PHASE PHASE DESCRPTION A B C 8KR P CR CR 1 P BKR A B C DESCRPTION MUS NORIA 500 20 1 1 2 2 20 1000 800111 HEATER OUTER GARAGE DOOR 2770 20 3 1 2 3 20 2770 :EXHAUST FAN GATES CENTER 500 2J 1 3 4 _ 1000 _ _ _ 2770 3 4 __ 2770 UNIDENTIFIED 2000 20 1 2 1 20 7000 UINOENTFED GATES S.GATES 500 20 1 5 6 1 20 500 MOTOR CONTROL 2770 5 8 2770 • UNDENTFEO 2O0 20 69 3 4 1 20 20 INIDENTFED EXHAUST FANS CONTROL 169 20 1 7 8 1 20 500 ,, M MOTOR CONTROL LONG EAST END 1500 20 1 7 �0 1 20 1500 - ILIGHRNG SOUTHWEST MO LNDENTFED 200 20 5 8 1 20 2000 UNOENTFED FRE ALARM PANEL 500 70 I 8 10 1 20 500 MOTOR CONTROL LCHING NE EIA 1509 20 1 9 10 1 20 1500 'UGHTNO SOUTH NEST BYDO ULCERATED 1500 20 7 8 1 20 1500 MCENTEE° ELEC ROOMREC 180 20 1 11 12 1 20 500 MOTORCONTROL LGHTNG SOUTH END 1500 20 1 11 12 1 20 1500 [UGH:A SOUTH NEST ENOI IINDENTFED 1500 20 9 10 1 23 1500 LINDENTFED ELEVATOR ROOM 1801 0 20 1 .13 14 - SPACE LIGHTING 2J G SOH EAST DOOR 1500 1 13 14 1 20 1500 -N.. NORTH MESTERE/ LNU/O C DENTFED 1500 2J 11 12 1 20 1500 ENTFED AEC PROJECT#: 15058 ELEVATOR ROOM 20 20 1 15 15 0 SPACE 1ST LEV IX/THL4-• 1500 20 1 15 : 1 - -• M6EST1ST D( U.6pENTFIEO 1500 20 13 14 1 23 1500 LNDENTFED ELEVATOR ROOM 100 20 1 17 16 1 20 500 BATTERY CHARGER — 1ST EL5...• 1 16 0 .SPACE UN/DEOWED 1500 21 15 16 I 20 1500 UNDENTFED DATE: ISSUE: WIRELESS LV CABINET WEST 360 20 1 19 21 1 20 600 HEATTRACE LEVEL SOUTH LIGHTS -1500 20 1 9 29 3 20_ 1663 HO-USEBOLER PIA UNOENTFEO 1500 20 17 18 1 20 2000 LNDENTFED WIRELESS LV CABINET CENT 360 20 1 21 22 1 20 500 MAN GATES UNOENTFED 0 20 1 21 22 1663 -- UNOENTFED 5817 30 19 20 1 23 200 UNIDENTFED WIRELESS LV CABINET EAST 360 20 1 23 24 1 20 500 NMN GATES SPACE _ 0 23 24 -- 1663 • - 5817 21 22 1 N 2000 UNOENTLIEO 07/16/15 PROGRESS MAN GATES 750 30 2 25 28 2 30 1000 800711455 BUS TERM.AR HANDLER 1805 20 3 25 -26 3 20 1385 HOUSE SOLERt4B 08711/15 FINAL REVIEW 750 27 26 1000 FROM PANEL LP2 1005 27 28 1385 581] 23 24 1 20 2000 LNIDENTFEO _ MOTOR CONTROL 500 23 ,1 29 30 2 60 A•• GE _ AT PARKINGOFFCES 1805 29 30 1395 U* M23- DEFED 2000 1 25 26 3 15 2909 UNDENTFED 08/19/15 PERMIT LNDENTFED 2000 20 1 27 28 2909 MOTOR CONTROL 500 20 1 31 32 _ 2000 SPACE 0 31 32 3 20 1863 PUMP/1 HOUSE SOLER UNIpEN3FE0 2000 20 1 29 30 2909 • 10/6/16 PERMIT UPDATE MOTOR CONTROL 500 _ 20 1 0 SPACE SPACE 0 33 34 1663 '- MOTOR CONTROL 500 20 1 0 APACE SPACE • 0 _ 35 30 1683 • UODENTFED 5817 30 3 31 32 3 15 290B WDENTFED - BO. 37 38 1 ii,, A ARL SPACE 0 37 30 3 20 139s .PUMP 64 FOR HOUSE BOLER • 5817 33 34 2909 280 39 A= LES AT BSMT SPACE 0 39 40 1385 - 36 .•- - •USE SOLER CONTROLS 100 20 1 41 20 360 WIELESS LAN ATBSMT SPACE 0 41 42 13955 SPACE 0 3 1.- .P-I L EM-2 0.••.67 CNM•491 SPACE • L. •CALCULATOR MARY MOVE HOUSE BOLER CONTROLS TO THIS POWER PANEL AS CLOUDED •••CALCULATION SUMMARY PROVIDE NEW 42 SPACE PANEL TO REPLACE EXISTING 30 SPACE PANEL SPACE 0 4139 411 40 19462 19482 - SOH AEC NEW CRCLXTS ARE CLOUDED.RENEW ON SITE LOCATIONS FOR BOILERS 11 S C. - CALCULATED •'J RFA •. C• SLATED POWER FACTOR PUMPS*3 04.AND AR HANDLER FROM PANEL LP2. LOAD CALCUUTON SUMMARY ELECTRCAL CONTACTOR TO TRACE AND DEN/FY LOADS AND CIRCUITS.PROVDE 095 089 •N • . a'w-e44 ...4•D DEMAND AMPS CONNECTED LOAD IC •..A. •E _.D OAD i •ND; -5 LOADS AND CIRCUITS TO ENGINEER FOR REVIEW �A*TL'T LGHTNGICONTI/OUS 1400• 7 1750 B LOHTNG 'i i 1:. CALCULATED POWER FACTOR: ANEL RECEPTACLES 15820 76 12910 62 RECEPTACLES 0 .. 0 0 0 005 CONNECTED L•.%- A• CTEDAMPS DEMAND LOAD DEMAND AMPS SCHEDULES MECHANICAL 5500 37 7000 40 LECHiAMCA{I-- 40.935 Ps/gg69 �®®424625 50 LO1-/RNG SZl05 52100 83 KITCHEN E. 0 0 0 TOTAL N'n,��./ i 0 .• L 0 0 & LOAD l r KITCHEN 98738 1190 106894 1310 TOTAL 23720 120 21860 110 TOTAL S3YS... 66983 _ 73 RECEPTACLES 0 0 0 0 0 0 .> •6 Y E i ANICEG TOTAL ,5,438 ,62 161534 NSA CALLS Date. (G (( -- ( SCALE:NONE By; - E1 • 1 __da: 2 of 3 ____,.... _o comp,200 20 5[Mu mom atom R NL_ wi TYPICALBO-CEILING ELECTRICAL LEGEND ELECTRICAL SPECIFICATIONS _GENERAL NOTES ALL SHEETS `t1�' (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH`WITH THE `a 0 RECESSED SURFACE D.Mus. A. General Requirements OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS: LJCONFIRM ALL LOCATIONS FOR LIGHT SWITCHES;ADD THREE WAYS IF (7..1 WSU MOUNTED UONTflOT050 AC -ABOVE COUNTER • FOUND NECESSARY. � 1 AFF -ABOVE PINISNED FLOOR 1, SCOPE Furnish all materials and labor required b execute this work Wil RECESSED FLUOR FLYruRE REVIEW RECEPTACLE LOCATIONS;MOVE AS REQUIRED.PROVIDE APO AISNE FINISHED GRADE as indicated on drawing and as specfied,as necessary b these r complete the © AHJ -AUTHORITY HAW.JURISDICTION UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. SURFACE FLUOR.LIGHT FIXnRE AL -Co..M contract Ebcthcal work shall include.but notlimiletl b. malar REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF MAIN CIRCUIT BREAKER 8 Pu1uRE DESIGNATIONS. CU CovPER items: • n BTHOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW.MOVE MRANCH CIRCUIT BREAKERS PPER CASE-POSTURE TYPE EC -ELECTRICAL CONTRACTOR LOWER GH-SI..DESIGNATION BA -EMERGENCY A. Complete Wirier tem for new lighting d shown. AS REQUIRED. IS 7E, MOUNTING HEIGHT Pc -GENERAL CONTRACTOR P Gays p gen power asn IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS.THE .N.. IS 7E,MINIMUM IS IB-. ® SHADING ON FIXTURE INDICATES EMERG.BATTERY RAMP CND -GROLmO including new panelboerls.new conduits,new wires eve wiring CFI -GROUND FAULT PHERRWTER devices,new control devices.etc.for a Complete power system ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. C d1R�Vrqq�� I—I 100001FLUORESCENT sm Ramo .lOn IN CONTRACT red for new and/or SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED CS %'2 00 Frr1 TRACK HORT AS ROTEo OR SCHEDULED NIC -0 IcALCcr a Complete pparats)inuallation as requiAND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR .Z em Q w 10ABURER electrical appanbs as shovm on single line diagram and TO PROCEEDING. -0 NPC -NpTTO SGIE N m ❑0 POST IOUNTED FIXTURE .REFERINGCAxTRACTOR dnv4ngs C C»La 4 POST IBOLWr0IFIXNRE PELF .•UNCeRENCED1 ❑ U DERONOUND b. Complete branch circuit wiring required for theergconnectioncs of 0 o 3 G '- g ® STEP Ls. UTO •UNLESS NOTED OTHERWSE emergency lighting and exit signs to existing emergency stand V Qa Uh v 0 CEILING OR WALL MOUNTED EXIT DONT uTP uNSHIE00E0 MISTED PMR by power system. E WP -WEATHERPROOF Q�1,0,1 R1E A eec BATTERY LIGHTS WNW -To•RSFORI.ER C �r._ •r �M;J Be DUPLE%RECEPTACLE O'FURLESS NOTED •1e- -I.OUNRNG HEIOHT TO CENTERLINE 2. Provide grounding and bonding Facilities- a1�— Oi0.CEAPP ORAPO SC ge DOUBLE DUPLIX RECEPTACLE B IS-UNLESS NOTED 0 Complete all electrical demolition as required. Qu�O� O• PLUSH ttCgi 0000000 RECEPTACLE FIRE ALARA.SYSTEMI L- •S B.m N FINISHED FLOOR • B SPECIAL OUTLET NOTED 'FRCP FIRE AURucoNTRr.PANEL 4. Caredr1001k.d patching of ezi ting building structure required for (:11) ,1g.,iD m B DUPLEX RECEPTACLE wLFSW TCHED ONE....TED I= FIRE ALARM ANNUNCIATOR PANEL end celectront work.Care hdrave stall followro Buildinglfrom Standard owneprocr poor CZL; CW NnO POP-UP RECEPTACLE O FIRE AURIN PauSTAn°x and Cantracbr shill have written approvals bt4Ming owner prior m 1b start of any work. W£•7M TYPICAL DEVICE xM° TELE-POWER 00 ALARMHOION SPEARER NORoSr00 Hr-- WLTtOUTLET 0.1X)STRIP �r>; cW.BIw.nON HORNrsTROBE OR SFEAKEasiRO9E 5 Test of entire system and work. u y= QO04 JUNCTIONS:WIN FLOOR CEIUNC OR IN WAIL •N THERMAL HEAT DETECTOR - N MOUNTING HEIGHTS TELEVISION OUTLET'H00 °RwALL 5MICKEAOMZATIONDETECTOR Operating.Maintenan a and identification instructions manuals L I--(> rou00510N DUTIET •P PHOTOELECTRIC SMOKE DETECTOR an C m TELEPHONE e....RO •Nm HEAT.PHOTOELECnUC SMOKE DETECTOR 8 PERMITS AND FEES.Obtain and pay for all necessary permits,mate, 0 2 Q NOT TO SCALE CONDUIT RUN CONCEALED IN WALL OR ABOVE CDWO It ITh DUCT DETECTOR Iona.examinations and fees or charges necessary for execution and Q < NOTES'. --►CIRCUIT MA.. OD SPR15KLER SYSTEM FLOW a wrLH completion of electrical work. • 1, HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX �•• g, „ UNLESS NOTED OTHERWISE. _--OARS roux BELOW FLOOR OR GRADE M SPRINKLER SYSTEM TAMPER SWITCH 7. REGULATIONS AND CODES H•�4` �� v�AII 'Rau'STuauP-CAPaw4m CD STROBE _ p0 ROio.-- 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP' Li' '''' SPOF DOOR TRIM AND CEILING LINE. $ SHORT uBSCEITCHAT As uNLE55NDTm ® SAOKEPRE DAMPER CONNEcnOx A. Applicable Inde revNatbnal Ebola Codendme Q • �3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS S5100CRIPR. W REMOTE INDwATDa LK1HT Conform b ths prevailing edition and tSF000 ems Hereto of Ne a.a F'Oe R COD _2.xpoLE mAtOH Town of Vail Elecbtral Code,pertinent NFPA,publications -�i (',aAND NOTED ON ELECTRICAL FLOOR%ANS SHALL GOVERN a•s AY SWITDHsECUen sysTEM G T• pL I Tm ._� k• AY SWITCH and b he requirements of Federal,Sbb or other City agencies f vs' ; 'i ,C IK EE'1 } S A gOVER THOSE SHOWN ABOVE. M.MOTIO0OPERATED aIATCH ® CONTKT DDDR nernUo Ia IAMB DR HINGE twang)unedlcbon. . 4. FOR CEILING HEIGHTS HIGHER THAN 7T,INSTALL FIRE ALARM A•KEYEIPERATEB OVERLOAD A 0, 0 NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80•AFF TO.MERMAL OVERLOAD SWITCH ®0 NmusmN Manx DETECTOR AS SPECFED COPROlrmowA B SHOP DRAWINGS AND SUBMITTAL'. , ' P.WIT.WITH PLOT LIGHT COta // OTHERWISE INSTALL AT 8"BELOW CEILING. A Contractor shall submd shop drawings for engineer review and approval. /U / C :_f� 'T 5. MOUNTING HEIGHTS PER IBC 2009 AND ADA CODES DE DeAER avnTUH W/WATTAGE 1 _ -.,..:,,,..,A..,... ` R1sN&Trott Coater.SWUM wYROPERATEp ACCESS SWITCH >CJ EILLANCE CAMERA B. Shop Mewing submittal shall include Date.. 1 roe oxcECRIC CELL • WI TCH gISRaBUnch E9avMENr SYMBOLS 1.Generator (t) THERMOSTAT AT es.UNLESS NOTED DISCONNECT 5wrc0 9 CONDUIT AND WIRE. B`/- • e GM40016Eg1AP0ENT �— FUSEE A. CONDUCTOR SIZES AND TYPES For sizes#1/0 AWG and larger.use 9 - I] 0000 SE0000 EOMPMENT --- CIRV,EIRE0KEa cower THW or aluminum XHHW For sines#1 AWG and smaller.use only //�� ..OMe+ux¢AnOH SYSTEMVvVy c CURRENT TRANSFORMER oW copper wire with 800V Insulation,types T ,THHN.or THW-stranded in COf,I. - - - -, Sib.HE and larger,solid in sites#10 and smaller.Control wing shall be 014. L.•l TRANSF Q(3). ..SPEAKER INLEIUrrG OR WALL METER aRMER stranded.Use type THHN for wires entering or passing through fluorescent O v0//e�.,001,4E CONTROL AT eP UNLESS NOTED ® MAONEnc MOTOR STARTER lighting fixtures.AM motors shall be ed oath copper conductors only ©©•I M0000rOs€OUREr IN FLOOR BOx OR RML 0• DISCONNECT SWITCHB MC Cobb permitted b d per cal codes.Run hard pipe from panel local ,� PANEBOMD OR CFNTER.RtI5H CAR SOWEDox.ALLAN SwITGI )unC0on band run MC cable from Junction boo to device La � $ PROGRAM telt r-w-----I oorrCne0R0.MOTOR CONTROL CENTER ORoenreUTON BOARD 10 SUPPORT I— A I I INTERCOM Q TRANSFORMER A. Support all eleclncal equipment independent of accessible ceilings as 1 p CLOCK --In GROUND requir by Z LC) Q AMPLIFIER ® CIRCUIT BREAKER etlNEC.NEG. 7 ® mon. ` CO Au TRANSFER 2 0 W co H 2 o I.WALL ASSEMBLY-THE 1.2,3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY CC < W I I SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL 1 ► ) O U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND Iee v II I�I © SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES'. Cl_y'LJ`rll A.STUDS-WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS(MAX 2 HR FIRE RATED 8#ee1UJ G`' O ASSEMBLIES)OR STEEL CHANNEL STUDS.WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN.(Sr BY 102 J MM)LUMBER SPACED 181N.(400 MM)DC WITH NOV 2 BY 4 IN.(51 BY 102 MM)LUMBER END PLATES I I I z 0 AND CROSS BRACES.STEEL STUDS TO BE MIN 3-548 IN.(92 MM)WIDE BY 1-3/8 IN.(35 MM)DEEP 1 1 E CHANNELS SPACED MAX 24 IN.(810 MM)00. B.GYPSUM BOARD•-NOM 12 OR 518 IN.(13 OR 18 MM)THICK.4 FT.(122 CM)WIDE WITH SQUARE .J OR TAPERED EDGES,THE GYPSUM WALLBOARD TYPE,THICKNESS.NUMBER OF LAYERS,FASTENER Q TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR 5400 SERIES �/ \ DESIGN IN THE UL FIRE RESISTANCE DIRECTORY MAX DIAM OF OPENING IS 28 INCONCENTRICALLY.(850 MM(. / / PANEL GEN � 2.THROUGH PENETRANT-ONE CONDUIT INSTALLED EITHER OR J ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM.THE ANNULAR SPACE BETWEEN PIPE,CONDUIT OR PROJECT TOVGENERATORVLLAGE PARKED ENGNEER. SOH TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 01N.(0 MM)(POINT CONTACT)TO MAX 2IN.(51 PROJECT 15058 VOLTAGE 120208V,IP.3W 011111111I MM).PIPE,CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED BOTH SIDES OF WALL ASSEMBLY. MOUMNSURFACE MANS bOA MLD THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES.CONDUITS OR TUBING MAY BE USED: TYPE INTEGRAL TO GENERATOR AC 10K A.CONDUIT-NOM 8 IN.(152 MM)DIAM(OR SMALLER)STEEL CONDUIT OR NOM 4IN.(102 MM)DIAM PHASE PHASE (OR SMALLER)STEEL ELECTRICAL METALLIC TUBING DAASCRP MIN A B BOO P CR CR P BKR I A B 'DESCRPTON I 3.PILL,VOID OR CAVITY MATER/AL.-CAULK OR SEALANT-MIN 5/8.1-1/4,1.7/8 AND 2-12 IN. ( BLOCK HEATER 750 30 2 1 2 T 20 1500 30 2 5 6 BATTERY CHARGER 18,32,48 AND 84 MM)THICKNESS OF CAULK FOR 1.2.3 AND 4 HR RATED ASSEMBLIES. 750 3 1 1 20 500 BATTERY CHARGER BLOCK HEATER 750 IO SPACE RESPECTIVELY,APPLIED WITHIN ANNULUS,FLUSH WITH BOTH SURFACES OF WALL.MIN 1/41N.(8 MM) , DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT 750e I 0 SPACE SPACE 0 9 10 0 SPACE LOCATION ON BOTH SIDES OF WALL AEC PROJECT It 15058 THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING SPACE 0 11 1Z ° SPACE Me•Pipe or Conduit F Rating T Rating OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED,AS SHOWN IN THE FOLLOWING TABLE. 0 3 14 0 Mon M.two Nr- Hr THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE 0 15 16 0 DATE: ISSUE: 17 10 11250 10r 2 0•.I or 2 PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. B 0 19 A O 0 11251 3 00 4 3 or 4 AS TABULATED TO THE LEFT. 71615 PROGRESS I e102T I or 2 0 3M COMPANY-CP 25WB•CAULK ORFS-3000 WT SEALANT. ° 0 - 23 24 ° 0 08111/15 FINAL REVIEW 0 25_J 33 D 06/19!15 PERMIT 6<l521 3 or 4 0 •BEARING THE UL CLASSIFICATION MARKING 0 27 2B 0 12 03050 I or 2 0 0 29 30 0 o '31 32 _ 0 10/6/16 PERMIT UPDATE 0 33 34 0 0 PENETRATION THROUGH A FIRE-RATED WALL _ - 3536 -- 3] 38 0 ° O 39 40 0 DN.lay C.a.So NOT TO SCALE 0 Al 42 0 SOH AEC LOAD CALCLAATIDN SUMMARY CONTRACTOR TOVERFY LOADS TO ENGINEER PR OR TO PULLED FEEDER CALCULATED POWER FACTOR ELECTRICAL 00 CONNECTED LOAD CONNECTED AMPS OE MONO LOAD DEMAND AMPS SPECS LIGHTNGCONTNUOUS 0 0 0 0 RECEPTACLES 4000 19 4000 19 MECHANCAL` • & LEGEND NfTCFEN 0 p ° 0 TOTAL 4000 19 4000 19 El •2 3 of 3 _e UPwwr IRE•Rm00AA DOELae crrore1L KC_