Loading...
HomeMy WebLinkAboutApproved Documents_1.pdf 75 South Frontage Road Expedited West, TOWN OFVAIL B18-0005 Vail,CO 81657 Issued: 01/10/2018 TOWN of VAIL(0. Office:9 70.479.2139 InspectionLine:9 70.479.2149 Property Information Address: 1210 LIONSRIDGE LP 4C (210312118019 4C)(210312118019) Unit#:4C ParcelNumber: 210312118019 LegalDescription: Subdivision:SAVOYVILLASCONDOMINIUMS Unit:4-C R654061 MAP 04-28-98R654291 DEC 04-30- 98 R807663 MAP 09-19-02R807664 DEC 09-19-02R834731 QCD 05-13-03 Contacts Co ntacfType:Applicant Full Name:MATTSEILER Address: 1401 WEST BAYAUD STREETDENVER,C080223 Phone: 3039451519 Co ntacffype:PropertyOwner Full Name:MULHOLLAND,TODD&MARY Address: Phone: None Contractor Contractor Type:General Company: Renewal By Andersen State License#: Phone: 303-217-4100 Pro jecinformation Pro jecName:Mulholland Residence 2018 Pro jecOescription: Replacing 7 windows,trim to match existing,U-value 0.32 or less. Fees Paid Acco unV:001-0000.31111.00-Building Permit Fee Fee Amount: $293.25 Account#:001-0000.31123.00 Building Plan ReviewFee Fee Amount: $190.61 Acco unt#: 110-0000.31060.00ConstructionUseTax Fee Fee Amount: $145.12 Acco unt#:001-0000.31128.00 Will Call Fee(Building Scope) Fee Amount: $5.00 TotalPaid: $633.98 Conditions CONDITIONS UNDER WHICHPERMITS BECOME VOID: If construction is not begun within 6 months from the date permitwas issued. If more than 5 months elapses betweeninspections. Ifincorrectinformationis given on the application at the time the permitwas issued. g , dit, . ChristopherJarecki-Townof Vail Building Official NOTICE: By issuance of this Permitthe applicantagrees to complywith all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # B18-0005 Date Printed: 01/10/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0005 Status: Approved Permit Number: Date Started: 01/09/2018 Permit Type: Expedited Subc ases Window Replacement Lot Number: Property: 1210 LIONS RIDGE LP 4C (210312118019 4C) (210312118019) Contacts Contact Type: Applicant Company Name: RENEWAL BY ANDERSEN Full Name: MATT SEI LER Address: 1401 WEST BAYAUD STREET DENVER,CO 80223 Email: mbeaudoin@renewalcolorado.com Contact Type: Property Owner Full Name: MULHOLLAND,TODD& MARY Address: Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $293.25 Plan Review 001-0000.31123.00 $190.61 Construction Tax 110-0000.31060.00 $145.12 Will Call Fee 001-0000.31128.00 $5.00 Payment Information Date Paid Payment Type Amount Will Call Fee 01/10/2018 Credit Card $5.00 Paid By: -Notes:visa-michael clancy Construction Tax 01/10/2018 Credit Card $145.12 Paid By: -Notes:visa-michael clancy Plan Review 01/10/2018 Credit Card $190.61 Paid By: -Notes:visa-michael clancy Permit Fee 01/10/2018 Credit Card $293.25 Paid By: -Notes:visa-michael clancy FEE TOTAL $633.98 AMOUNT PAID $633.98 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 01/10/2018-3:15:24 PM-Generated by:cgodfrey 1/1 SPECIFICATIONS AND TECHNICAL MANUAL PERFORMANCE RATINGS AND TESTING DATA =ICTURE WINDOW PERFORMANCE TEST RESULTS r Air Water Forced Entry Wind Load Resistants Operating Farce Tightness Tightness Res75WnCc DP60 Performance Grade Ratings DP60 DP60 NA N A Air infiltration'f I <01 scfmlftt CAN/CSA Fixed 84 C4 NIA N A A440-M98 Our picture windows meet or exceed these test requirements. ANS(IAAMA! 'NW DA F-R60 F•R60 F•R60 N/A N/A 1011E.5.l 97 'Air Infiltration rates are the flow of air which passes through lenestrat on products These values are obtained through the Ha mark Certification program and tested according to ANSIIAAMAINWWDA 101/15.2 97 or 101/15 2INAF5 02 Th.,maximum a:owable air infiltration is 0,30 cfm/W. THERMAL AND SOLAR HEAT GAIN PERFORMANCE FULL-FRAME PICTURE WINDOWS INSERT PICTURE WINDOWS Thermal Performance Values Solar Heat Gain Coefficient Thermal Performance Values Solar Heat Gain Coefficient Unit Average"U"Factor lSHGC'I Unit Average"U"Factor (SHGC) _._-�... . .. .. .. . F ..Hq- Hi t. 3''F. 'f; GAS FILL Ar' Pxrbr..a i,,, r,. 7 nce rlce`" 1vr' PRr o- -arta .fir' re� rcr�t ;,,r .,rfor tante q. Blend .8_ir d' Eerie B end 1 'NTERNAL OR LIES 'q.4•. (FDL) vnthourlwrt� vntfrout1with wttlioiut/with wIthoutf.ith . enrart pit without/vor xi""" ut/with w)ftout/with Gear .441.45 .421.43 .61 1.55 .61 1.55 .451.46 .431.44 .641.57 .641.57 High .31 171 .32 .2 .28 331.29 .32 I.29 V. Performance Glass .31 1.33 .27119 .34131 .341.31 y N 'Hi9 ' 5 Rerfo`rrnance .311.33 .271.29 .201.18 .201.18 .311.33 .281.29 .211.19 201.19 'Sun Glass f'rc- tfi h z. Performa rye .301.32 .261.28 .221.20 .221.20 301 32 171.28 23 121 .231.21 5tiwr1Sun 1 An argon gas blend sealed between the glass to help inh'bit the transfer of energy(heat or cold). 2 Any unit used in high alt.tude should uti ize a capilary breather tube.For such units,the gas fill;s regular air. 'Numbers based on FDL GBG may vary slightly. September 2012 CONFIDENTP.AL Technical Data 8-35 SPECIFICATIONS AND TECHNICA - MAF. u .•. L PERFORMANCE RATINGS AND TESTING DATA PICTURE WINDOW, cont. GLASS OPTICAL PERFORMANCE CHARACTERISTICS PICTURE WINDOWS Sh ding Visible Light Ultraviolet Coefficient(SC) Transmittance Light (VT) Transmittance Clear 89 6: High. Perfomiani:e"' 48 .Glass GLASS TYPE H:gh- Performance .29 • Sun Glass :H . Perforrrrance .31 5mait5unTM OTHER TEST DATA PICTURE W.NDOWS Relative Heat Gain "U"Factor i Relative Humidity Inside 5ut}ace etu Hr. ft' V.hcn f lnisture Farms Glass Temperature{F) center of glass center of g,ass • nV antergT glass ntenteass Clear 186 .48 39% 44° High- Performanc& 99 .25 61% 55° Glair GLASS TYPE High- Perfortoance 62 .25 61% 54° .Sart Glass Huh- Performance 66 .24 61% 56° SmarlSun' "Center of glass"values are generally lower than whole unit values,and are useful ONLY for comparing glass performance,not window performance. SOUND TRANSMISSION High-Performance' 30 24 GLASS TYPE High-Performance 32 29 Temperedllarmnate 8-36 Technical Data CONFIDENTIAL September 2012 SPECIFICATIONS AND TECHNICAL MANUAL PERFORMANCE RATINGS AND TESTING DATA GLIDING, GLIDING-STATIONARY, GLIDING-PICTURE WINDOW PERFORMANCE TEST RESULTS Air Water Performance Forced Entry Tir htnes. Tic htness Wind La,-,d Resistance ❑pernting Force J ] Gide Rfsist7nce INIMMINNIMMEI • DP40" Performance Grade DP35(DP25)"r DP35(DP25)" H—IE Ratings AIr07 scfmlft'm IDP15]tt [DP151tt PG15-35" 8 15 lbs. Level 10 CANlCSA A2 82 CI Passed Passed A440-M98 8-15 lbs. ANSIIAAMAI H5 C35 HS-C35 NWWOA HS C40 (HS-LC25)t (HS-LC25)t 8-15 lbs. Level 10 10111 5 2-97 (HS-LC40)1 NS-815111 IHS-R15)tr ' Air Infiltration rates are the flow ad air which passes through fenestration products.These values are obtained through the Hallmark Certification program and tested a:co•ding to ANS1'AAMAINWWDA 10111.5 2 97 or 101115 2INAF5•02.The maximum allowable air infiltration is 0.30 cfmlfti. "" DP;PG ratings dependent on un t configuratici and s ze.Please refer to Gliding Window Section of this Spec and Tech Manual for c mails. t Performance rat ngs in parentheses apply to gliding and gliding-stat'onary windows taller than 60"or wider than 72": and gliding-p cture windows taller than 60"or wider than 84"(ONE dimension in extended maximum range). tt Performance ratings in brackets apply to gfding-picture windows taller than 60'AND wider than 84"(BOTH dimensions in extended max mum range). THERMAL AND SOLAR HEAT GAIN PERFORMANCE FULL-FRAME GLIDING WINDOWS INSERT GLIDING WINDOWS Thermal Pcrtorc.cance V,Ilucs Solar Heat G.;n Coelhcient Tirenvai Pr.rforn77nCL''ill ILWt Soi,r Hn•.t Galrr Corfficicnt Unit Avcrr je"0"Factnr ISHGC} tlnitA.ra:.tgc"II"Factnr (SHC.C) 110- Hrg• ..—-. Hyl• r • GA5 FILL Aire Perforiiagcen' Arra Performance Air Pei[nrmance Aire Performance Blend Wendt Biendt Blend '•NTERNAt GRILLES (FOE) y��Iwith without with without with without with without with without with without/with without with Clear .471.47 .451.45 .591.53 .591.53 .471.47 .451.45 .591.53 .591.53 High- .34 .301.31 .321.29 .3 21.28 t Performance Glass .341.35 .301.31 .321 29 .311.28 I- r. High 5 Performance .341.35 .301.32 .201.18 .191.18 34!.35 301.32 .261.18 T9! 18 Sun G ass High Performance .331.34 ,x91-31 21 1,19 .21/.19 .331.34 .291.31 .21 1,19 .21/.19 5mattSunn't • 1 An argon gas blend sealed between the glass to help inhibit the transfer of energy(heat or cold) 2 Any unit used m h'gh altitude should utilize a capillary breather tube.For such units,the gas Ells regular air •Numbers based on FOL,GBG may vary slightly. September 2012 CONFIDENTIAL Technical Data 8-33 SPECIFICATIONS AND TECHNICAL MANUAL PERFORMANCE RATINGS AND TESTING DATA GLIDING, GLIDING-STATIONARY, GLIDING-PICTURE WINDOW, cont. GLIDING WINDOWS VisWit!Light • Lthrovinie: Shadrng 'Fr Irt!mItt.wcv Light CoLflicI(:rit(SCJ (VT) Iromir ittarce v'.4,44-04706174‘.': Clear .89 .82 .58 High GLASS TYPE Perfor"Mance' .48 .72 .16 Glass 16:1!. Perfor-Ance .29 .40 .16 • Sun Glass 1 F c•-• Performance .31 .65 .05 SmartSunti" OTHER TEST DATA GLIDING WINDOWS Heat Gain Relative flurnirlity Inside Surflce "Factor Gtuiu Fir. ft V.rcrt P.1:).:tlire Fr,mi; GlissTer.pvtztLite(F) center of glass nleco1g.is artar.f glass cen!,olct ar 186 4 39% 44 Pc461rnance 99 61% 55" • .GlisT GLASS TYPE Pe'rformanci 62 .25 61% 54 HE,V: Pifforliance 66 .24 61% 56 1 •Cart of glass"va!ues are generally lower than whale uni vatues,and are useful ONLY for comparing glass performance,not window performance. SOUND TRANSMISSION STC Rgh-PerformanceT" 30 24 GLASS TYPE High-Performance 32 29 Tempered/Laminate 8-34 Technical Data CONFIDENTIAL September 2012 NEXT TUBES PLEASE.OCD ON#5 MULHOLLAND,TODD 115-17-988 JONATHAN BLAIR No No HOMEOWNER: JOB#: INSTALL MANAGER UP? FACTORYMATERI/ NOTES PLEASE.NOTE PWU. ADDRESS: 210 LIONS RIDGE LOOP#4 CITY/STATE/ZIP: VAIL 81657 Cell Phone: 720.940.0259 GLASS? LEAD-SAFE WORK No a a, "X" :o "X" i7 at c 01 c cc e 0 r a oLo � w* `, W2 �swoW _ N y0L w o S1/ S / S2 S2 a F n 1 n v c r• AD 15 AD . * 75 a -o y m >, o a a 3 o na , d3 W 3 H W H Location o a Style 2 m ,O3 WO x -¢ Uo D D WO 3 O x 0., . U U 7 O U o x BUNK RM 1 1 CS Base NONE 34 1/4 46 1/8 1/4 1/4 34 45 7/8 so 1 WH PN 1891 R Stone F GUEST 1 2 1 GL Base NONE 58 3/4 58 5/8 1/4 1/4 58 1/2 58 3/8 u, 1:1 WH PN i89 i89 SA Stone F MASTER 3 1 GL Base NONE 83 58 3/4 1/4 1/4 82 3/4 58 1/2 1.1 2:1 WH PN 189 i89 SA Stone F LIVING 4 1 GL Base NONE 47 1/8 69 3/4 47 1/8 69 3/4 II, 1:1 WH PN i89 i89 SA Stone S LIVING 5 1 PWU Base NONE 47 1/8 69 3/4 47 1/8 69 3/4 n, 1 WH PN i89 LIVING 6 1 PWU Base NONE 47 1/8 15 47 1/8 15 62 1 WH PN i89 LIVING 7 1 PWU Base NONE 47 1/8 15 47 1/8 15 62 1 WH PN 189 The window replacement has been approved by the Board. Please send whatever form you need the HOA to complete! From:Catie May[mailto:cmay@renewalcolorado.com] Sent:Monday, December 18, 2017 8:00 AM To:Todd M ulholland<todd mulholland@vahoo.com>; Amy VanGoey<amy@BoldSolutions.net> Subject:RE: Savoy Villas ARC request form needed for M ulholland @ 1210 LionsRidge Loop 4C Hello Todd, I have not heard anything, and have copied Amy at Bold Solutions on this. Amy, do we have word yet on a decision? Kind Regards,1 Ga7 Catie (Cat)May HOA Administrator RBA 1 Colorado 1401 West Bayaud Avenue, Unit 7 Denver,Colorado 80223 0:303-217-4076 Fax:303-974-6943 0 Renewal byAndersen, recognized by UP.Pnwer for "OutstandingCustomer m , Satisfaction with --__,=, WI ndaws and Patio Dome' From:Todd M ulholland [mailto:todd mulholland@yahoo.com] Sent:Saturday, December16, 2017 7:52 PM To:Catie May<cmay@renewalcolorado.corry Subject:Re: Savoy Villas ARC request form needed for M ulholland @ 1210 LionsRidge Loop 4C Hi Cat- Thanks. Checking in to see where things stand with the HOA and town of Vail approval? Thanks Todd On Dec 5, 2017, at 10:03 AM,Catie May<cmay@renewalcolorado.conv wrote: Hi Todd, I've confirmed, the single casement is in the bunk room. Kind Regards, Cat May Home Owner Association Administrator Renewal by Andersen of Colorado, Philadelphia, Southern New England & Telefluent Communication,Inc. 1401 West Bayaud Avenue, Unit 5 Denver, Colorado 80223 Direct # 303.217.4076 Fax # 303.974.6943 <i mage007.jpg> From:Jonathan Blair Sent:Tuesday, December05, 2017 10:01 AM To:Catie May<cmay@renewalcolorado.corr Cc: ErikThor<ethor@renewalcolorado.com> Subject:RE: Savoy Villas ARC request form needed for M ulholland @ 1210 LionsRidge Loop 4C The bunk room is not getting a gliding window. It's a casement: <image001.png> ...and it meets egress, with room to spare: <image002.png>