Loading...
HomeMy WebLinkAboutinspector_summary_45008_03-13-2018-14548.pdf Inspection Summary TOWN OF (°)IVAILI Inspection Result: Pass Inspector: John Boggs Permit Type Inspection Type Address Electrical Electrical Final 2310 CHAMONIX RD (210311415022) (210311415022) (210311415022Parcel B) Inspection Date: 03/13/2018 Permit#: E17-0164 TMK: 210311415022Parcel B Applicant name: New Electric Inc- Beth Smart Email: Beth@NewElectricColorado.com Phone: Comments: 1. Unit c: in use cover and outlet on front porch not secured to dwelling. No bulb in exterior light on back egress (don't know if the fixture works). Can light in mechanical closet is not secured to the dwelling. 7111 _ 2. Unit b: Unit a : in use cover on front porch gfi not grounded. Missing outlet in the garage. e 111 • 3. Inspector Signature (-/) 4. Applicant Signature 5. Unit a : outlet lose on lower vanity, in use cover on front porch gfi not grounded. ti 6. Unita , b and c pass.