SWEET BASIL TAB 11-16-2014.pdf
TEST, ADJUST AND BALANCE REPORT PROJECT SWEET BASIL #1114 PREPARED FOR CLIMATE CONTROL COMPANY REPORT ISSUE DATE 11/16/2014 PREPARED BY HVAC TAB IIc P.O. BOX 1926 VAIL, CO 81658 PHONE: 970-376-5198 E-MAIL: mrichardson@hvactab.co HVAC TAB lic TEST, ADJUST AND BALANCE REPORT. THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS. ANY VARIANCES FROM THE DESIGN REQUIREMENTS ARE NOTED THROUGHOUT THIS REPORT. THE RESULTS SHOWN AND INFORMATION PRESENTED IN THIS REPORT IS CERTIFIED TO BE ACCURATE AND COMPLETE, TO THE EXTENT POSSIBLE BY EQUIPMENT AND PROCEDURES USED THROUGH- OUT THIS SURVEY. THE FINAL AIR DISTRIBUTION SYSTEM MEASUREMENTS ARE IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS FOR TESTING, ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. H ( ! ,4/2-011. CERTIFIED BY: DATE: THE FINAL HYDRONIC DISTRIBUTION SYSTEM MEASUREMENTS ARE IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS FOR TESTING,ADUSTING AND BALANCINGJOF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIED BY: DATE: HVAC TAB Ilc WARRANTS THAT THE AIR AND HYDRONIC SYSTEM EVALUATED DURING THIS SURVEY IS OPERATING AT THE SPECIFIED LEVELS AS SHOWN WITHIN THIS REPORT, AT AND ONLY AT THIS TIME. HVAC TAB 1k MAKES NO OTHER WARRANTIES, STATED OR IMPLIED, CONCERNING THE CONTINUED PERFORMANCE, OPERATION OR SAFETY IN THE USE OF THIS EQUIPMENT PASS THIS TIME. CERTIFIE0 Michael T.Richardson HVAC TAB,lic Page: Y #13-084-03 Expires: 2122/2015 `NATIONAL BALANCING COUNCIL HVAC TAB I l c INSTRUMENT CALIBRATION REPORT DATE: 11/15/2014 PROJECT : SWEET BASIL PROJECT ALTITUDE: "HG INSTRUMENT/SERIAL# APPLICATION DATE OF USE CALIBRATION CALIBRATION DATE DUE DATE SHORTRIDGE ADM-870C/#M09211 AIR FLOW READINGS 11/15/2014 06/12/2014 06/012/2015 ANEMOMETER#RVA501416001 AIR FLOW READINGS NOT USED 04/14/2014 04/14/2015 SHORTRIDGE FLOW HOOD AIF FLOW READINGS NOT USED * * TH-720 HYGROMETER/#TH7200950003 AIR TEMP/HUMIDITY NOT USED 06/04/2014 06/04/2015 PITOT TUBE 18" PRES.READINGS NOT USED N/A N/A PITOT TUBE 24" PRES.READINGS NOT USED N/A N/A PITOT TUBE 36" PRES.READINGS NOT USED N/A N/A PITOT TUBE 48" PRES.READINGS NOT USED NA NA SHIMPO TACHOMETER /#C105B0010 RPM READINGS 11/15/2014 06/18/2014 06/18/2015 FLUKE 375/#21290229 VOLT/AMP 11/15/2014 06/04/2014 06/04/2015 SHORTRIDGE HDM-250/#W08162 WATER PRES.READINGS NOT USED 06/12/2014 06/12/2015 ASCROFT/0-100 PSI/#DO68332-06 WATER PRES.READINGS NOT USED * * FLUKE 52-II#99780167 TEMP.READINGS NOT USED 02/3/2014 02/3/2015 REFRACTOMETER RHA-100 /#RHA- GLYCOL%READINGS NOT USED N/A N/A 100 *CHECKED TO CALIBRATED METER REMARKS: ALL READINGS WITH SHORTRIDGE INSTRUMENTS ARE CORRECTED FOR TEMPERATURE AND ALTITUDE. PAGE: HVAC TAB lic FAN TEST REPORT DATE: 11/15/2014 PROJECT: SWEET BASIL SYSTEM: KEF-1 FAN NUMBER KEF-1 NOT USED UNIT DATA UNIT DATA UNIT DATA MANUFACTURER TWIN CITY FAN MODEL 182-QSLR SERIAL J14517555-1-1 SCHEDULE RATING/OUTLET TOTAL 6600-7600CFM@1.6"SP MOTOR DATA MOTOR DATA MOTOR DATA MANUFACTURER TOSHIBA - MOTOR HP RPM 7.5 1760 PHASE FRAME 3 213 T S.F. TYPE 1.15 1 KKH VOLTS AMPS 230/460 19.6/9.8 DRIVE DATA DRIVE DATA DRIVE DATA MOTOR DRIVE BORE 2 VP 60 1 3/8" FAN DRIVE BORE NA 1 3/8" NO. BELTS SIZE 2 AX57 DRIVE CHANGE ROTATION +0 TURNS/+3-3 CORRECT STARTER DATA STARTER DATA STARTER DATA MFG. MODEL SCHNEIDER - RANGE SET AT (AMPS) 16-24 AMPS 19.6 AMPS SET AT HERTZ REQ. THERM - - THERMAL PROTECTION - - II TEST DATA TEST DATA TEST DATA CFM VOLTS 7143 209/208/209 FAN RPM AMPS 2206F/1788M 12.1/12.8/12.0 0� 0 NOTES: NA DENOTES NO ACCESS PAGE: R(011t 14, 0 0. 1 0 lZ):1DYS):_ 307 ;4 257 ik.L2LAti I ` f '4 7?) VoYo v;/;-7°1, q,7c/IK c-Pi‘A \Je.l) (1) vitrf ®FF 122•- 1 CY vA i...{ J Qo , . ( v cr-oieg ` I 9ve t`. HVAC TAB iic KITCHEN HOOD TEST REPORT woad - i REPORT: LOCATION: V 4,E, "j 4 rj 6� DATE: HOS in"A TYPE: CLIENT: 5 t,.,t 13z s i I MFG: ADDRESS: SERIAL: ATTN: EQUIP ID: GREASE FILTER I ©AKE VELO�CITYREADINGS f� /f�v ,23 � a6 ; o7 / ( ( ( 7 JZ2_ X6)5- ) 71 -to L Lct )3% ;9] 771 311, 3(° c., CANOPY: I 6.2 I`/S FILTER RACK: U 0 4 L AIRFLOW DATA AVERAGE GREASE FIL 1'ER VELOCITY GREASE FILTER AREA FACTOR MEASURED TOTAL EXHAUST CFM 7� DESIGN TOTAL EXHAUST CFM MEASURED TOTAL MAKE UP AIR CFM DESIGN TOTAL MAKE UP AIR CFM SMOKE TEST f RESULTS PASSED TEST INSTRUMENTAL DATA MANUFACTURER MODEL TEST PROBE SHORTRIDGE ADM 870 VELGRID PAGE: HVAC TAB Ilc KITCHEN HOOD TEST REPORT N0°) - REPORT: LOCATION: ° Pe, DATE: 1)/i 5/(k( TYPE: CLIENT: S Pe Be,s ,t I MFG: ADDRESS: SERIAL: ATTN: EQUIP ID: GREASE FILTER INTAKE VELOCITY READINGS t� )(-13 t57 17() p97 17, 40C- 353- 3?7 Ica 171 ' 2- 2q0 . 3z- (u.sr 43 1 CANOPY: I .; (0 / S FILTER RACK: 0/1�r AIRFLOW OW DATA AVERAGE GREASE FILTER VELOCITY GREASE FILTER AREA FACTOR MEASURED TOTAL EXHAUST CFM DESIGN TOTAL EXHAUST CFM MEASURED TOTAL MAKE UP AIR CFM DESIGN TOTAL MAKE UP AIR CFM SMOKE TEST RESULTS PASSED TEST INSTRUMENTAL DATA MANUFACTURER MODEL TEST PROBE SHORTRIDGE ADM 870 VELGRID PAGE: HVAC TAB lic KITCHEN HOOD TEST REPORT REPORT: LOCATION: F 'yP DATE: l 1 / I S`! `1 TYPE: CLIENT: . e ti- h I ) MFG: ADDRESS: SERIAL: ATTN: EQUIP ID: GREASR•FIL3IR INTAKE VELOCITY READINGS '1 571 SQ7 115-;.`0 �.. 39 .25S- • bas�7 ( Dol 177-Cc" CANOPY: C7/3 el FILTER RACK: 61071 AIRFLOW DATA AVERAGE GREASE FILTER VELOCITY GREASE FILTER AREA FACTOR MEASURED TOTAL EXHAUST CFM DESIGN TOTAL EXHAUST CFM MEASURED TOTAL MAKE UP AIR CFM DESIGN TOTAL MAKE UP AIR CFM SMOKE TEST RESULTS PASSED TEST INSTRUMENTAL DATA MANUFACTURER MODEL TEST PROBE SHORTRIDGE ADM 870 VELGRID PAGE: • 4. ...