HomeMy WebLinkAboutA18-0007_Approved Documents_1523903230.pdf 1410 OF v./ �► ' �)I�i1�� l Technologies LLC P.O.Box 4831 Eagle CO 81631 Cell:970.688.0621 # �-Y 11 email:dimitrovdimant@gmailcom T qoJ 4 Vail Fire&Emergency Services 04/16/18 Project:The Market at Vail Address:Tree Top Plaza, Vail CO 81657 F ire alarm contractor: The Best electric AC POWER CIRCUIT INFORMATION Digitally signed by Daniel Dimitrov DN:cn=Daniel Dimitrov,o=Dimant ��y� Technologies LLC,on, i•• email=dimitrov.dimant@gmailcom, c=US D ate:2 018.03.0419:57:51-07'00' Existing 120 VAC, 20 Amps dedicated circuit. Daniel Dimitrov— NICET Fire alarms Level III Cert.# 119879 ° F I/4 ,c9.40440/1e. Fire and Em: i 2399 N. F Z Vail, TOWN OF VAIL ' TFP-4. ' Fire& Emergency Services vv "q01 Vail Fire&Emergency Services 04/16/18 FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: Office Use: NA Tree Top Plaza NA Project#: (Number) (Street) (Suite#) Building/Complex Name: The Market at Vail Building Permit#: Alarm Permit#: Contractor Information: Lot#:____Block#____S ubdivision: Company: The Best Electric Company Address: P.O.BOX 273 Detailed S copeand Location of Work: Please see City:EAGLE State:CO Zip: attached scope of work letter. Contact Name: Louis Romersheuser Contact Phone: 970-3 28-1610 E-Mail thebestele@gmail.com (use additional sheet if necessary) Does a Monitored Fire Alarm Exist? Yes(') No( I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate fire alarm sys- Does a Sprinkler System Exist? Yes(') No( tern drawings and state that all the information as required is cor- rect. I agree to comply with the information and fire alarm system Work Class: drawings,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision New(r) Addition(L) Remodel(�) Repair ) codes,design review approval, National Fire Code, International Retro-Fit(fl) Other(fl) Building and Residential Codes and other ordinances of the Town applicablet ereto. Type of Building: X S S Ingle-Family ) Duplex( ) Multi-Family ) Commercial(F1 Restaurant(F) Other(r ) Contrac Signature(required) Property Information Complete Valuation for Fire Alarm Permit: Parcel#:210106404030 Fire Alarm$: $3000.00 (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: Date Received: Owner Name: 2014-0916 ° F I/4 415.% 497 TOWN OF VAIL o Fire& Emergency Services0 * j4117014 Vail Fire&Emergency Services Fire Department Process 04/16/113 For Commercial& Residential Fire Alarm Systems Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the following: NA A Colorado Registered Engineer's stamp X Device locations on reflected ceiling plans X Reflected Ceiling Plans (RCP) X Typical device wiring diagrams X Battery calculations Battery calculations X A list of specific device model numbers X Equipment cut sheets of each type of device X The number of each type of device X Information indicating the specific zones X Circuit diagrams X Point to point wiring diagram X Wiring type,size and number of conductors X The source of AC power circuits X Fire alarm panel locations NA Knox Box location X Information indicating monitoring method and monitoring agency This check list has been provided to ensure that our review process may be handled in a timely manner. I have read and understand the above listed submittal requirements: Project/Street Address: Tree top plaza, Vail CO 81657 Contractor Signature: Date Signed: 2014-0916 F z•4 4 Technologies LLC 497 P.O.Box 4631 Eagle CO 81831 Cell:970.688.0621 email:dimilrov.dimanl@gmail.com j4117014 Vail Fire&Emergency Services 04/16/18 Project:The market at Vail renovations Address:Three tops plaza,Vail,CO 81657 Fire alarm contractor:The Best Electric BATTERY CALCULATONS Alarm Panel:Silent Knight 5820XL 1. Alarm Panel Current Draws: 1.1. Existing in standby mode: 0.28A 1.2. Existing in alarm mode: 1.76A 1.3. Projected in standby mode: 0.30A 1.4. Projected in alarm mode: 3.30A 1.5. 24 hours in standby backup required: 7.20A 1.6. 15 minutes in alarm backup required: 0.81A 1.7. Total backup (24 hours stby+15 min in alarm): 8.01A 1.8. 15%battery ware factor: 1.20A 1.9. Total minimum backup required: 9.21A 1.10. Existing battery backup value: 18.00A 2. NAC 2 circuit: 2.1. Existing in standby mode: O.00A 2.2. Existing in alarm mode: O.00A 2.3. Projected in standby mode: 0.00A 2.4. Projected in alarm mode: 0.92A Manufacturer maximum current load per NAC circuit permitted:2.0A All existing values have been measured on-site with the alarm panel in the responding condition. Digitally signed by Daniel Dimitrov DN:cn=D aniel D imitrov,o=D Imam /^moi Technologies LLC,au, CC%��Jl••11 mail=dlmitrov.dimant@gmail.com, c=US Date:2 018.03.0817:09:2 1-07'00' Daniel Dimitrov—NICET Fire alarms Level III Cert.#119879 ittiti DF 10 ! Project: The Vail Market Remodel .,,; Address: Tree top plaza,Vail CO 81657 Z 4 Fire alarm contractor: The Best electric dg CIRCUIT DAGRAM ::i r Vail Fire&Emergency Services 04/16/18 r II r II II SLC - exiting 0 devices r1 F P P 11 • 0 A 1 15cd c 1W1 P 1 15cd NAC2ncl—Dl_ni— ial<1_)2(1 ): 1 75cd 75cd zn,,il 75cd 75cd 75cd Digitally signed by Daniel Dimitrov 7jAry o=:cn-Daniel rov Tecnologies email=dimitrovxkmant@gmail.c =US Dale 2018.03.081]16320]'00' Daniel Dimitrov NICET Level III Cert.#119879 1410 OF /! ' 1)I)i11N►l Technologies LLC P.O.Box 4831 Eagle CO 81631 Cell:870.688.0621 O, # �-Y email:dimitrov,dimant@gmailcom TgoJ 4 Vail Fire&Emergency Services 04/16/18 Project:The Market at Vail Address:Tree top plaza, Vail CO 81657 Fire alarm contractor: Best Electric DEVICE MODEL LIST 1. Horn Strobe Combo— System Sensor PC2RL 2. Strobe— System Sensor SCRL 3. Duct detector with built in relay— Silent Knight— SD505-DUCTR Digitally signed by Daniel Dimitrov / o=Dimant DN:cn=DanielTechnologrrologov, 0(11'n72.4.1/ hr'�� ies LLC,ou, email=dimitrov.diment@gmail.co m,c=US Date:2018.03.04 16:3438-07'00' Daniel Dimitrov— NICET Fire Alarms Level III Cert.#119879 �T I)I�i1�� 1 Technologies LLC 7 P.O.Box 4631 4 Eagle CO 81831 Cell:970.688.0621 vriemail:dimitrov.dimant@gmail.comcr4 Vail Fire&Emergency Services 04/16/18 Project:The Market at Veil Address:Tree top plaza, Vail CO 81657 Firealarm contractor: The Best electric DEVICE NUMBER LIST 1. Horn Strobe Combo - 4 2. Strobes—4 3. Duct-smokedtecetors- 2 Digitally signed by Daniel Dimitrov o=DrmaDaniel oologov, email=di Technomgit[ogrn oo, mai l=di mitrov.di mant�g m a i I.<o =110 Date:2018.03.08 17:18:58-0700' Daniel Dimitrov—NICET Fire alarm Level III Cert.#119879 1410 OF ! �► ' � 1)I�i1�� l 4:11 lail Technologies LLCen P.O-Box 4831fietly Eagle CO 81631 Cell:970.688.0621 O �-Y 51 ie-mail:dimitrov,dimant@gmail-com gin 4 Vail Fire&Emergency Services 04/16/18 Project:The Market at Vail Address:Tree top plaza, Vail CO 81657 F ire alarm contractor: The Best electric F IREALARM PANEL LOCATION T 1 / CEILING TTRANSITION w i EIL.ING TRR ANSITION lk Zt —--J a rr 9 II DASHED LI EOFPROD a P CASES(TII £l *106 1 II 1 1F/STUD _L__ DRYWALL SOFFIT I fir'-10^ FACP ELFCTICALCl- IR HSI I •0.0.NEW FURRED SLOPED D.W.CEILING 0.,:109'-17R' BASE OF SLOPE 0 13N1EW-U'RRED FLAT DWCEIJNG 2nd floor electrical room Digitally signed by Daniel Dimitrov DN:cn=Daniel Dimitrov,o=Dimant 7�,y� Technologies LLC,ou, email=dimitrov.dimant@gmail.com •. mail=dimitrov.dimant@gmail.cam c=US Date:2018.03.04 20:03:41-0700' Daniel Dimitrov— NICET Fire Alarm Level III Cert.#119879 1410�i1�� l OF /! �► ' i �)I Technologies LLC P.O.Box 4831 EV Eagle CO 81631 Cell:970.688.0621 0 �-Y e-mail:dimitrov,dimant@gmaitcom T#gi n lb Vail Fire&Emergency Services Project:The Market at Vail remodel 04/16/18 Address:Treetop plaza, Vail CO 81657 Fire alarm contractor: The Best electric SCOPE OF WORK LETTER 1. Pre-wire in accordance with NEC, NFPA 72, NFPA 720 and town of Vail Fire Departm entam endm ents: 1.1. 2 Dict-smokedetectors; 1.2. 4 strobe locations; 1.3. 4 horn-strobecombo locations; 2. Install in accordance with NFPA 72, NFPA 720 and town of Vail Fire Department amendments: 2.1. 2 Silent Knight SD505-DUCTRaddressable photo-electricduct-sm oke detectors; 2.2. 2 System Sensor SCRL ceiling mount strobes; 2.3. 4 System Sensor PC2RL ceiling mount horn-strobecom bo; 3. Relocate existing manual pull station from the loading pock area to the main entry vestibule on the North side of the building. 4. Mapping: 4.1. Activate newly installed notification appliances on any alarm state of the FACP. 4.2. Activate the duct-sm okedetectors build-in relays to shut off the HVAC equipment in an event of smoke has been detected in the duct air system.Generate a latching supervisory signal. Digitally signed by Daniel Dimitrov DN:cn=Daniel Dimitrov,o=Dimant 7 yy� Technologies LLCou, ( ,• email=dimitrov.dimant@gmail.com ,c=US Date:2018.03.08 17:11:36-07'00' Dniel Dim itrov— NICET Fire alarms Level III Cert.#119879 INTELLIV ittiti OF£' ORY VL111 4 SILENT Model SD505- ,v41tk 01 KNIGHT roc IP- V',' S D 5 05 w ir &-`""! ' Services 04/16/1; by Honeywell Detect smoke in air handling systems and preventre-circulation with Silent Knight's addressable duct smoke detector The SD505-DUCTR addressable duct smoke detector detects smoke and products of combustion present in air moving through an HVAC air handling system.The SD505-DUCTR is a heavy duty metal housing with a pre-installed SD505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn,depending on programming and wiring, turns off fans, blowers,and other dev ices. Now there's even more power and flexibility available to the IntelliK night family of products.For more information on this product or to locate your nearest source,please call 800-328-0103. Model SD505-DUCTR Features .„, „': Analog Duct Smoke • Two-wire connection to SLC ( ' \ 4. '`. Detector with Relay • Detects and limits spread of smoke Module • LED alarm indication and communication on sensor head EF,•,,. The Model SD505-DUCTR ,• Rugged steel backbox with clear Addressable Duct Smoke Detector plastic cover with Relay providesearly detection Installation template included t ai'— of smoke and products of combustion present in air moving • No screens or filters to clean SD505-DUCTR through an HVAC duct to prevent • SD505 APS Photoelectric Smoke re-circulation of smoke into the air Detector pre-installed handling system.The SD505- • 3 standard tube lengths DUCTR is a heavy duty metal • UL listed, complies with NFPA72 • housing with a pre-installed and 101 • SD505-APSAnalog Photo Electric • CSFM listed Smoke Sensor and relay module. • MEAApproved429-92-E, Vol9 When smoke is detected in a duct, • FM Approved the unit communicates the SD505-DTS-K condition to the IntelliKnight FACP. Specifications The built-in relay module, in turn, Physical Environmental turns off fans, blowers,and other Dimensions: 21/4” H x 9” L x 71/4" W Operating Temp: 32°F to 100°F dev ices. Weight: 3Ibs (0°C to 37°C) Operation Electrical Humidity:10%-85% non-condensing Air sampling accomplished byOperating Voltage:24 VDC Other Ratings: p g is Alarm Relay Contact rating: two tubes which protrude into the 10A @ 24 VDC;10A @ 115 VAC; Air Velocity 300 -4000 ft/min duct.An exhaust tube of one 10A @ 240 VAC Samp ling Tubes: standard length (7.5") is provided SD505-T2 2.5ft sampling tube with the detector housing. Intake Trouble Relay Contact Rating: 2.5A @ 30 VDC SD505-T5 5ft sampling tube sampling tubes (ordered SD505-T10 10ft sampling tube separately) are supplied in three Aux. Power Input Current: standard lengths. Duct mounting is 20mA Standby, 62 mA Alarm accomplished through a template SLC Input Current:0.5 mA and 4 sheet metal screws Max. SLS resistance:50 Ohms (provided). INTELLIKNIGHTACCESSORY ° DF I/4 S 4 Model SD505-DUCTR and SD505-DTS-K47, Duct Smoke Detector with Relay and Remote Test Switch V ,1' IQ014 Vail Fire&Emergency Services 04/16/18 Engineering Specifications The air duct smoke detector shall be Silent Knight Model SD505-DUCTR and remote test switch shall be SD505-DTS-K. The housing shall contain a Silent Knight model SD505-APS,Photoelectric Smoke Sensor. The duct detector shall be of metal construction. Complete mechanical installation must be able to be performed without remov al of the detector cover. Terminal connections shall be screw type using a minimum of#6 screw. ] i---- , FACP/5815XL / Connection SC- 5+ SC- S+ ] IM SLC OUT SLC IN 11IJ ■ L�IIL +j CND PILO' 0 LE O "'At." � avD -V xc-rreoua,.e no mar I GMS I N O Oreo • 1 1-1 U 1 - - - - Irl Nj C C�� C�� ? C�� C,� Class A (Style 6) Nn PLEA • �. sI c- SLC+ FACP/5815XL j r<�i i moi. �� W ///grw�� s Connection ` 'l '1 ��� SC— S+ SC— S+ U_ 4. '4 4, 4 4 SLC •U SLC IN DTS-K connection PBT M TFST °D xc Tar." �ED LED IMIN in q q q q q M Class B (Style 4) SILENT nMADE IN AMERICA keep This our productdocumentis informationnotinteded upt-to-datetobeused and for accurate.installation Wpurposes.e cannot coveraWelltryto N t KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350005 Rev B subject to change without notice.For more information, contact Silent Knight Copyright©2011 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. www.silentknight.com 40 OF frit SPECIFICATIONViic Is z SPECIFICATIONS RATING SD505-DUCT SD505-DUCTR , -kin 1 Alarm Relay Contact Rating V 10A @ 24VDC 10A @ 115VAC Vail Fire&Emergency Services 04/16/18 10A @ 240VAC Trouble Relay Contact Rating 2.5A @ 30VDC Operating Voltage 24VDC Aux. Power Input Current 20mA Standby 62mA Alarm SLC Input Current 0.5mA 0.5mA Maximum SLC Resistance 50 Ohms 50 Ohms Operating Temperature _ 32F — 100F 32F '- 100F Humidity 10% — 85%RH Non-Condensing 10% — 85%RH Non-Condensing Air Velocity Rating 300 — 4000 ft./min. 300 — 4000 ft./min. / . z. . / ., / N, , , EXHAUSTTUBE // / INfIAKE III. ELECTRICAL INSTALLATION HOLE& &HOLE& CONNECTOR r CONNECTOR A. GENERAL INFORMATION IJ r 2t y vr4. 4 rn`\ l., Wiringmust conform to applicable local codes,ordinances and regulations LOW PRESS / v•' (' HIGH PRESSURE PP SIDE I eiri�e J 0 't�,7� �� • SIDE covering these types of devices. Wire the detectors according to the engineering drawings for the particular job requirements. These detectors ' li''si ,;;,1 I t%pi are not intended for open area protection,nor should they be used for o'rp open air protection. Refer to NFPA 90A and NFPA 72 for general and - j/ additional information on Duct Smoke Detectors concerning operation and installation. Terminals are suitable for up to #14 gauge wire. / B. DETECTOR WIRINGDWYER#4000DIFFERENTIAL )PRESSURE GAUGE(OR ING 1. With power source de-energized and the smoke detector not installed,wire EQUIVALENT)SIZRUBBERTWTTH STOPPERS SIZE 0 RBBER STOPPERS all connections per engineering drawings. Refer to the applicable figures below (HA PART#0700-01118). depending on your duct housing model number. FIGV�Ic ONNG 2. With all wiring in place,install the detector head. 3. Energize the duct detector. _________—_—_—_—_ 1 C. WIRING DIAGRAMS ANALOG SENSOR I L I L2 ® +R i STANDBY and ALARM current should SD505-DUCT WIRING DIAGRAM be 0.55mA The SD505-DUCT is not a self-contained sensor. , This product is compatible only with fire alarm USED control panels that utilize Silent Knight's Digital i O O O3 NOT Communications Protocol. ` a O z0 z z z o SC (-) O OO FAN SHUTDOWN EXAMPLE SD505-DUCTR WIRING DIAGRAM OBSERVE POLARITY INPUT VOLTAGE 24 V.D.C. SUPPLY VOLTAGE E \\ 20 mA Standby �� 62mA Alarm lF• ADDRESSABLE LOOP 13 11 1 2 C) 10 11 12 ® O O ® Test GND PILOT ALARM S SW LED LED REMOTE TEST NCC NO NCC NO SWITCH ALARM CONTACTS TROUBLE U L LISTED 10.0A @ 250VAC 10.0A Q 250VAC SD505-DTS CONTROL PANEL (Test function only. Does not reset.) s (1) - .__7"--• \ A.A. a ANALOG ADDRESSABLE TO NEXT SENSOR CONTROL OR RETURN PANEL 0_ SC(-) FIELD LOOP WIRING TO CONTROL PANEL Terminate Remote Accessories as indicated above(f required)./ This is not a self-contained stand alone detector. A U.L.Listed Analog Addressable Fire System is required. Installation Instructions(P/N 1700.09882 HA-06094)Page 2 of 3 Specifications subject to change without notice.•September 2014 AO OF Iv, LP 110 fel. ' SYSTEM ti- 1 SENSOR'` -• •-�f ..:�.. -i_ o] 1 . • • Vail Fire&Emergency Services / 04/16/18 _ Indoor Selectable- 'ire- ' Output Strobes and 4 ' - `' % Horn Strobes for __- pp CeilingApplications .. . ' r } System Sensor L-Series audible visible notification products arerich with features guaranteed t ocut -- installation times an dmaximize profits with lower _ current draw andmodern aesthetics. • Features The System Sensor L-Series offers the most versatileand • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-v olt operation L-Series can meet v irtuallyany application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15, 30,75,95, 115, 150, and 177 strobes include a varietyof features that increase their application v ersatilitywhile simplifying installation.All dev ices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Univ ersalmounting plate for ceiling units consuming ground faults. • Mounting plate shorting sp ring feature checks wiring continuity To further simplify installation,the L-Series utilizes a univ ersal before dev ice installation mounting p late so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting sp ring,installers can test wiring Adv ancedev ices continuity before the dev ice is installed. • Compatible with MDL3 sync module Installers can also easily adapt dev ices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-v oltoperation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 0 APPROVEDpli LISTED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 ..244114 OF ire L-Series Specifications Architect/Engineer Specifications ' General iQ07.6141 L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch backbox,4-inch octagon back box,or gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch backbox.A universalmounting plate shoulIF1TTe&shrgency Services for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the univ ersalmounting plated l ,t-Series products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 v olts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.lndoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-way erectified unfiltered powersupply. Ceiling strobes and horn strobes shall hav efield-selectable candela settings including 15, 30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall b e approved for fire protective sery ice.The strobe shall be wired as a primary-signaling notification appliance and comp lywith the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz ov erthe strobe's entire operating voltagerange.The strobe light shall consist of a xenon flash tubeand associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective sery ice.The horn strobe shall be wired as a primary-signaling notification appliance and comp lywith the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltagerange.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall hay etwo audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set bya multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded powersupply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective sery ice.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models ov era single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch backbox.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multip lezones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded powersupply. Physical/Electrical Specifications Standard OperatingTemperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(M DL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) InputTerminalWire Gauge 12 to 18 AWG Ceiling-MountDimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-M ountSurface M ount Back Box Skirt Dimensions 6.9"diameterx 3.4"high(175 mm diameterx 86 mm high) (SBBCRL,SBBCWL) Notes: 1. Full Way eRectified(FWR)voltageis a non-regulated,time-varying power source that is used on some powersupply and paneloutputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 ..,.....".. id UL Current Draw Data ltIA V UL Max.StrobeCurrent Draw(mA RMS) ' 8-17.5 Volts 16-33 Volts O- �� 5' Candela DC DC FWR -- 15 87 41 60 Vail Fire&Emergency Services 04/16/18 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RM S),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn StrobeTones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86800 ..4...9"4°. tElria IA L-Series Dimensions Is cri Oe fP, 2.47 = = Oj .01 iQo0b 1.37 c>6.92 — 2. • co 6.83 ail Fire&Emergency Services 4/16118 ooaor►arq MI Rij" I �+ o CD o 8 1 '\, ::.:...,:,;','::', 0',,:‘,,,', ',''.:::. iLill Q Q i IIO 1, Jo O o8 Ceiling-M ountHorn Strobes Ceiling Surface Mount Back Box 0 tallii..--'4111111\ zws ori y,�,.pr,,•1 1 OOOp... mm oOpp 114-141-1lY�laO� pQ0 ieaa, 1,,, '' OW' ',0'4',4 `;, ti I Go- a fist ;,rrw;, _ ,„. . , ��Oopp tr iso��/ Ceiling M ountHorn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Univ ersalCeiling Trim Ring Red TRC-2W Univ ersalCeiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White *T SYSTEM ©2017 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensor.com �_� SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latestversion of this data sheet. AVDS86801•03/17 .,,,,t:Abh) SYSTEM WIRING �'�'' The 2 -wire horn strobe, chime strobe and strobe only require two wires fors ire power and supervision . (See Figure 7 . ) Please consult your FACP manufac- turer or power supply manufacturer for specific wiring configurations and special cases . FIGURE 7. 2-WIRE CIRCUIT FROM INPUT ---1---j � � OUTPUT FACP TO OR NEXT PRIOR 71 _87-TIMM, 7. ' {�'p� DEVICE DEVICE � • oo ' � I _ _ . ' OR EOL •in.iff-7ore -1 I _ - A0367 -01 1410 OF /! ' � 1)I)i11N►l Technologies LLC P.O.Box 4831 Eagle CO 81631 Cell:870.688.0621 O, # �-Y �i email:dimitrov,dimant@gmailcom TgoJ 4 Vail Fire&Emergency Services 04/16/18 Project:The Vail Market remodel Address:Tree top plaza, Vail CO 81657 F ire alarm contractor: The Best electric WIRE TYPE INFORMATION 1. NAC wiring— FPLR 16 AWG, 2 conductors 2. SLC wiring— FPLR 18 AWG, 2 conductors Digitally signed by Daniel Dimitrov DN:cn=Daniel Dimitrov,o=Dimant �PriTechnologies LLC,ou, i•• email=dimitrov.dimant@gmail.co re,c=US Date:2018.03.04 18:29:18-07'00' Daniel Dimitrov—NICET Fire Alarms Level III Cert.#119879 1410 OF Tr � I � I)I�I��� 1 0 TechnologiesANT f:i P.O.Box 4631 E N. Eagle CO 81631 Cell:970.698.0621 0J 1:111 e-mail:dimitrov.dimant@agrnail.com i in 4 Vail Fire&Emergency Services 04/16/18 Project:The market at Vail Address:Tree top plaza, Vail CO 81657 Firealarm contractor: The Best Electric ZONES INFORMATION Zones and reportingcodes are to be determent and defined with the monitoring station by installer, and tested prior and final fire inspection. Digitally signed by Daniel D Imitrov I V' I Tech n logics l Dimitrov,o=Dimant ��y� Technologies LLC,ou, i v• mail=dimitrov dimant@gmail.core, c=US Date:2 018.03.052230:17-07'00' Daniel Dimitrov— NICET Fire alarms Level III Cert.#119879