Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F18-0015_approved documents_1524177144.pdf
75 South Frontage Road Fire-Construction Permit West, TOWN OFVAIL F18-0015 Vail,CO 81657 Issued: 04/19/2018 TOWN of VAIL(0. Office:970.479.2139 InspectionLine:970.479.2149 Property Information Address: 5185 MAIN GORE DRS (209918220009X 209918220009) Unit#: P a r ce IN u mber: 209918220009 LegalDescription: Subdivision:VAIL MEADOWS FIL 1 Lot:18 R757134 QCD 05-11-01 R809489QCD 09-20-02R843562 QCD 08-01-03 Contacts ContactType:Applicant Full Name:Clint Janssen Address: P.O.Box 1055 P.O.Box 1055 Vail,CO 81658 Phone: 19709145014 ContactType:PropertyOwner Full Name:KENNETH H.GORDON REVOCABLE TRUST Address: Phone: None Contractor Contractor Type:Fire Protection Company: Vail Valley Fire SprinklerCorp State License#:CO-491 Phone: 970-914-5014 Projectlnformation ProjectName:Gordon/MasonResidence 2016 ProjectDescription: Install new residentail fire sprinklersystem per all interanational and local codes. Fees Paid Accounl#:001-0000.31111.00-Fire SuppressionPermitFee Fee Amount: $1,572.50 Accounl#:001-0000.21123.00 Fire SuppressionReviewFee Fee Amount: $432.00 TotalPaid: $2,004.50 Conditions Issued By:Town of V ailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicantshall forfeitall applicable fees. VAIL VALLEY FIRE SPRINKLER CORPORATION VAIL VALLEY FIRE SPRINKLER CORP. 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970)914-5014 GORDON - MASON RESIDENCE 5185 MAIN GORE DRIVE VAIL, CO 81657 3/29/2018 HYDRAULIC CALCULATIONS rFrPrD r y r FIRE PROTECTION DESIGN,INC. 13147 BIRCH WAY,THORNTON,CO 80241{303}920.6941 PAUL D.HUBBARD-NICET III-#708227 -PC...-Q-- .-/-1 .,-t,0a3 Hydraulic Calculations for Project Name: GORDON/MASON RESIDENCE Location:, VAIL,COLORADO 81657, Drawing Name: 180302.cad Calculation Date:3/29/2018 Design Remote Area Number: 1 Remote Area Location: FIRST FLOOR GARAGE Occupancy Classification: Residential Density: 0.100gpm/ft2 Area of Application: 272.88ft2(Actual 272.88ft2) Coverage per Sprinkler: 256.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 51.61 @ 49.239 from Pump at Node:4: 51.61 @ 88.881 Type of System: Volume of Dry or PreAction System: N/A for Node: 1 Date: 3/14/2018 Location: Source: CLINT JANSS EN Name of Contractor: VAILVALLEY FIRE SPRINKLER CO Address: 57 HEREFORD LANE,EDWARDS, CO 81632 Phone Number: (970)914-5014 Name of designer: PAUL HUBBARD. Authority Having Jurisdiction: VAIL FIRE Notes: M.E.P.CAD,Inc. i���AutoSPRINK2018 v14.1.4.0 1 3/29/201812:53:59PM Page 1 NI Hydraulic Summary Job Number:180302-RemoteArea Report Description:Residential(1) Job Job Number Design Engineer 180302 PAUL HUBBARD. Job Name: State Certification/License Number GORDON/MASON RESIDENCE 108221 Address 1 AHJ VAIL FIRE Address 2 Job Site/Building VAIL,COLORADO 81657 Address 3 Drawing Name 180302.cad Systel I I Remote Area(s) Most Demanding Sprinkler Data Occupancy Job Suffix 4.9 K-Factor 25.60 at 27.295 Residential Remote Area 1 Hose AllawanceAt Source Density Area of Application 0.00 0.100gpm/ft2 272.88ft2(Actual 272.88ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Node F low(gpm) 2 256.00ft2 Total Hose Streams 0.00 System F IowDemand Total Water Required(Including Hose Allowance) 51.61 51.61 Maximum Pressure Unbalance In Loops 0.000 Maximum VelocityAbove Ground 18.94 between nodes 10 and 11 Maximum Velocity Under Ground 5.49 between nodes 1 and 2 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 108.57ga1 Supplies . Hose F low Static Residual F low Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) °g (gpm) (psi) °g (gpm) (psi) (psi) 1 Water Supply 58.500 45.000 1200.00 58.460 51.61 49.239 9.221 4 Pump 75.000 66.000 55.00 98.102 51.61 88.881 9.221 Pumps:Static=Churn(Pressure @ Zero F low) Contractor .111 Contractor Number Contact Name Contact Title 028 CLINT JANSSEN Name of Contractor Phone Extension VAIL VALLEY F IRESPRINKLERCO (970)914-5014 Address 1 FAX 57 HEREFORDLANE Address 2 E-mail EDWARDS,CO 81632 blazeinvail@aol.com Address 3 Web-Site Ly ©M.E.P.CAD,Inc. AutoSPRINK2018 v14.1.4.0 3/29/2018 12:40:28PM Page 2 Hydraulic Graph Job Name: GORDON/MASON RESIDENCE N 1.85 Remote Area Number: 1 Date:3/29/2018 100 Water Supply Summary Sheet 90 Node: 1 80 70 Available Supply 60—Static Pressure 58.500 51.61 . 58.460 .N 2 50 1.61 @ 49.239 1200.00 @ 45.000 a 40 30 System demand curve 20 10 0 -uwmimii 111111111 111111111 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Flow-gpm 1/&©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.1.4.0 3/29/2018 12:54:27PM Page 2 Hydraulic Graph Job Name: GORDON/MASON RESIDENCE N 1.85 Remote Area Number: 1 Date:3/29/2018 150 Pump Summary Sheet 135 Combined Static Pressures 133.500 Node: 4 120 105 'vailable Pump and Supply 51.61 @ 98.102 90 51.61 @ 88.881 •N Q 75 Pump Churn Pressure 75.000 N 60 •5.00 @ 60.000 Suppler 45 System demand curve 30 15 0 uiiininn iii i i i i i i 11111 I I I I I I I I I I IIIIII I I I I I I I I I I I I i i 0150 300 450 600 750 900 1050 1200 1350 1500 Flow-gpm Pump Rating 55.00 @ 66.000 Supply:Static:58.500 Residual:45.000 Flowing:1200.00 �M ©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.1.4.0 3/29/2018 12:54:27PM Page 3 i Summary Of Outf lowing Devices I Job Number:180302-Remote Area 1 g:-...-%' - Report Description:Residential(1) Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) Olt Sprinkler 101 25.60 25.60 4.9 27.295 Sprinkler 102 26.01 25.60 4.9 28.180 b Most Demanding S prinklerData E,©M.E.P.CAD,Inc. In AutoS PRINK2018 v14.1.4.0 3/29/2018 12:54:42PM Page 4 Job Name: GORDON/MASON RESIDENCE Remote Area Number: 1 Date: 3/29/2018 Supply Analysis Static Residual F low Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 1 Water Supply 5 8.5 00 45.000 1200.00 58.460 51.61 49.239 Pump Analysis Churn Residual @ F low Available @ Total Demand Required Pressure Node (psi) (psi) (gpm) (psi) (gpm) (psi) 4 75.000 66.000 5 5.00 98.102 51.61 88.881 Node Analysis Node Number Elevation(F oot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 1 0-0 Supply 49.239 51.61 101 12-6 Sprinkler 27.295 25.60 102 10-9 Sprinkler 28.180 26.01 2 17-11 37.833 3 17-4 P1 21.991 4 17-7 P2 88.881 (-66.999) 5 20-7 Gauge 86.455 6 27-0 83.168 7 27-0 80.983 8 27-0 73.719 9 15-6 74.269 10 15-6 65.5 06 11 12-11 30.341 12 12-11 29.216 13 11-2 29.183 LM,©M.E.P.CAD,Inc. All AutoSPRINK 2018 v14.1.4.0 3/29/2018 12:55:01PM Page 6 Job Name: GORDON/MASON RESIDENCE Remote Area Number: 1 Date:3/29/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (0) Actual ID Length (Foot)Total (psi) (Foot) Friction(Pf) directly to(Pf)and shown as a ,og't"Q S'ai..o 101 12-6 4.9 25.60 3/4 (See 0-5 150 27.295 Route 1 Sprinkler, Notes) 4-0 -0.172 12 12-11 25.60 0.8110 4-5 0.476082 2.093 T(4-0) 12 12-11 1 (See 0-6 150 29.216 Notes) 8-0 11 12-11 25.60 1.0550 8-6 0.132243 1.124 T(8-0) 11 12-11 26.01 1 (See 54-0 150 30.341 Notes) 21-0 -1.120 Flow(q)from Route 2 10 15-6 51.61 1.0550 75-0 0.483852 36.285 7E(3-0) 10 15-6 11/4 (See 27-5 150 65.506 Notes) 21-0 9 15-6 51.61 1.2910 48-5 0.181026 8 763 3T(7-0) 9 15-6 11/4 (See 11-6 150 74.269 Notes) 13-0 -4.986 0.181026 2E(3 0),T(7 0) 8 27-0 51.61 1.2910 24-6 4.435 8 27-0 1% (See 19-2 150 73.719 Notes) 21-0 7 27-0 51.61 1.2910 40-2 0.181026 7 265 3T(7-0) 7 27-0 1% (See 13-4 150 80.983 Notes) 14-0 0.079920 T(9 0),E(5 0) 6 27-0 51.61 1.5270 27-4 2.185 6 27-0 11/2 (See 6-5 150 83.168 Notes) 2.775 5 20-7 51.61 1.5270 0.079920 BOR 6-5 0.512 5 20-7 1% (See 3-0 150 86.455 Notes) 11-0 1.307 4 17-7 51.61 1.5270 14-0 0.079920 1.120 sCV(11-0) 4 51.61 Pump 88.881 Rating:66.000 @ 55.00 3 Churn Pressure:75.000 3 17-4 1% (See 7-7 150 21.991 Notes) 31-0 -0.242 2 17-11 51.61 1.5270 38 7 0.079920 16.084 3E(5-0),BFP(-5.000),PRV(-8. 000),BaIV(7-0),T(9-0) LHS,©M.E.P.CAD,Inc. di AutoSPRINK2018 v14.1.4.0 1 3/29/2018 12:55:19PM Page 7 Job Name: GORDON/MASON RESIDENCE Remote Area Number: 1 Date:3/29/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (0) Actual ID Length Total (psi) (Foot) (Foot) Friction(Pf) directly to(Pf)and shown as a...9Ut,.,o.,a,..9 2 17-11 2 (See 135-0 150 37.833 Notes) 18-7 7.758 0.023754 E(5-10),T(11-8),GV(1-2),S 1 0-0 51.61 1.9590 153-7 3.649 0.00 49.239 Hose Allowance At Source 1 51.61 Total(Pt) Route 1 102 10-9 4.9 26.01 3A (See 0-5 150 28.180 Route2 Notes) - Sprinkler, 2-0 -0.172 — 13 11-2 26.01 0.8110 2 5 0.490339 1.175 E(2-0) 13 11-2 1 (See 11-1 150 29.183 Notes) 3-0 I -0.758 11 12-11 26.01 1.0550 14-1 0.136203 1.916 E(3-0) 30.341 Total(Pt) Route 2 &©M.E.P.CAD,Inc. di AutoSPRINK2018 v14.1.4.0 1 3/29/2018 12:55:19PM Page 8 Job Name: GORDON/MASON RESIDENCE Remote Area Number: 1 Date:3/29/2018 [Equivalent Pipe Lengths of Valves and Fittings(C=120 only) r—IC Value Multiplier II Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90°Elbow EE 45°Elbow Eel 111/4° Elbow Ee2 221/2°Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap LHS,©M.E.P.CAD,Inc. di AutoSPRINK2018 v14.1.4.0 1 3/29/2018 12:55:19PM Page 9 Hydraulic Calculations for Project Name: GORDON/MASON RESIDENCE Location:, VAIL,COLORADO 81657, Drawing Name: 180302.cad Calculation Date:3/29/2018 Design Remote Area Number: 2 Remote Area Location: THIRD FLOOR BEDROOM Occupancy Classification: Residential Density: 0.100gpm/ft2 Area of Application: 154.78ft2(Actual 154.78ft2) Coverage per Sprinkler: 256.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 52.12 @ 48.045 from Pump at Node: 4: 52.12 @ 87.419 Type of System: Volume of Dry or PreAction System: N/A for Node: 1 Date: 3/14/2018 Location: Source: CLINT JANSS EN Name of Contractor: VAILVALLEY FIRE SPRINKLER CO Address: 57 HEREFORD LANE,EDWARDS, CO 81632 Phone Number: (970)914-5014 Name of designer: PAUL HUBBARD. Authority Having Jurisdiction: VAIL FIRE Notes: M.E.P.CAD,Inc. i���AutoSPRINK2018 v14.1.4.0 2 3/29/201812:47:07PM Page 1 NI Hydraulic Summary Job Number:180302-Remote Area 2 Report Description:Residential(2) Job Job Number Design Engineer 180302 PAUL HUBBARD. Job Name: State Certification/License Number GORDON/MASON RESIDENCE 108221 Address 1 AHJ VA IL F IRE Address 2 Job Site/Building VAIL,COLORADO 81657 Address 3 Drawing Name 180302.cad Syste Remote Area(s) Most Demanding Sprinkler Data Occupancy Job Suffix 4.9 K-Factor 25.60 at 27.295 Residential RemoteArea2 Hose AllawanceAt Source Density Area of Application 0.00 0.100gpm/ft2 154.78ft2(Actual 154.78ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Node F low(gpm) 2 256.00ft2 Total Hose Streams 0.00 System F IowDemand Total Water Required(Including Hose Allowance) 52.12 52.12 Maximum Pressure Unbalance In Loops 0.000 Maximum VelocityAbove Ground 19.13 between nodes 14 and 15 Maximum Velocity Under Ground 5.55 between nodes 1 and 2 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 108.57ga1 Supplies . Hose F low Static Residual F low Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) @° (gpm) (psi) °g (gpm) (psi) (psi) 1 Water Supply 58.500 45.000 1200.00 58.459 52.12 48.045 10.414 4 Pump 75.000 66.000 55.00 97.834 52.12 87.419 10.414 Pumps:Static=Churn(Pressure @ Zero F low) Contractor Contractor Number Contact Name Contact Title 028 CLINT JANSSEN Name of Contractor Phone Extension VAIL VALLEY F IRESPRINKLERCO (970)914-5014 Address 1 FAX 57 HEREFORDLANE Address 2 E-mail EDWARDS,CO 81632 blazeinvail@aol.com Address 3 Web-Site Ly ©M.E.P.CAD,Inc. AutoSPRINK2018 v14.1.4.0 3/29/2018 12:44:56PM Page 1 Hydraulic Graph Job Name: GORDON/MASON RESIDENCE N 1.85 Remote Area Number:2 Date:3/29/2018 100 Water Supply Summary Sheet 90 Node: 1 80 70 Available Supply 60—Static Pressure 58.500 52.12 . 58.459 .N a a) N 50-52.12 @ 48.045 1200.00 @ 45.000 a 40 System demand curve 30 20 10 0 111111111 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Flow-gpm 1/&©M.E.P.CAD,Inc. AutoSPRINK 2018 v14.1.4.0 3/29/2018 12:47:21PM Page 2 Hydraulic Graph Job Name: GORDON/MASON RESIDENCE N 1.85 Remote Area Number:2 Date:3/29/2018 150 Pump Summary Sheet 135 Combined Static Pressures 133.500 I Node: 4 120 105 vailable Pump and Supply 52.12 @ 97.834 90-52.12 @ 87.419 •N Q 75 Pump Churn Pressure 75.000 a 60 5.00 @ 60.000 Supple System demand curve 45 30 15 0—uiuiiiiiii iiiiiiiii 111111111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i i i i i i i i 0150 300 450 600 750 900 1050 1200 1350 1500 Flow-gpm Pump Rating 55.00 @ 66.000 Supply:Static:58.500 Residual:45.000 Flowing:1200.00 �M ©M.E.P.CAD,Inc. 111 AutoSPRINK 2018 v14.1.4.0 3/29/2018 12:47:21PM Page 3 i Summary Of Outflowing Devices I Job Number:180302-RemoteArea2 g:-...-%' - Report Description:Residential(2) Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) 4 Sprinkler 201 25.60 25.60 4.9 27.295 Sprinkler 202 26.52 25.60 4.9 29.284 b Most Demanding S prinklerData E,©M.E.P.CAD,Inc. In AutoS PRINK2018 v14.1.4.0 3/29/2018 12:47:36PM Page 4 Job Name: GORDON/MASON RESIDENCE Remote Area Number: 2 Date: 3/29/2018 Supply Analysis Static Residual F low Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 1 Water Supply 5 8.5 00 45.000 1200.00 58.459 52.12 48.045 Pump Analysis Churn Residual @ F low Available @ Total Demand Required Pressure Node (Psi) (psi) (gpm) (psi) (gpm) (psi) 4 75.000 66.000 5 5.00 97.834 5 2.12 87.419 Node Analysis Node Number Elevation(F oot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 1 0-0 Supply 48.045 52.12 201 41-9 Sprinkler 27.295 25.60 202 38-9 Sprinkler 29.284 26.52 2 17-11 36.572 3 17-4 P1 20.674 4 17-7 P2 87.419 (-66.854) 5 20-7 Gauge 84.972 6 27-0 81.677 7 27-0 79.452 14 27-0 75.893 15 27-0 63.173 16 38-7 47.988 17 39-3 31.5 35 18 42-3 28.268 19 39-3 30.336 LM,©M.E.P.CAD,Inc. All AutoSPRINK 2018 v14.1.4.0 3/29/2018 12:47:54PM Page 6 Job Name: GORDON/MASON RESIDENCE Remote Area Number:2 Date:3/29/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (0) Actual ID Length (Foot)Total (psi) (Foot) Friction(Pf) directly to(Pf)and shown as a ,og't"Q S'ai..o 201 41-9 4.9 25.60 3/4 (See 0-6 150 27.295 Route 1 Sprinkler, Notes) 2-0 -0.208 18 42-3 25.60 0.8110 2-6 0.476082 1.180 E(2-0) 18 42-3 1 (See 11-10 150 28.268 Notes) 3-0 1.301 17 39-3 25.60 1.0550 14-10 0.132243 1.967 E(3-0) 17 39-3 26.52 1 (See 15-10 150 31.535 Notes) 17-0 0.278 Flow(q)from Route 2 0.492637 3E(3 0),T(8 0) 16 38-7 52.12 1.0550 32-10 16.175 16 38-7 1 (See 11-7 150 47.988 Notes) 9-0 5.032 15 27-0 52.12 1.0550 20-7 0.492637 10.152 3E(3-0) 15 27-0 1 (See 16-10 150 63.173 Notes) 9-0 0.492637 EE(3 0),2E(3 0) 14 27-0 52.12 1.0550 25-10 12.720 14 27-0 11/4 (See 9-4 150 75.893 Notes) 10-0 0.184313 E(3 0),T(7 0) 7 27-0 52.12 1.2910 19-4 3.559 7 27-0 1% (See 13-4 150 79.452 Notes) 14-0 0.081371 T(9 0),E(5 0) 6 27-0 52.12 1.5270 27-4 2.225 6 27-0 1% (See 6-5 150 81.677 Notes) 2.775 5 20-7 52.12 1.5270 0.081371 BOR 6-5 0.521 5 20-7 1% (See 3-0 150 84.972 Notes) 11-0 1.307 4 17-7 52.12 1.5270 14-0 0.081371 1.140 sCV(11-0) 4 52.12 Pump 87.419 Rating:66.000 @ 55.00 3 Churn Pressure:75.000 3 17-4 1% (See 7-7 150 20.674 Notes) 31-0 -0.242 2 17-11 52.12 1.5270 38-7 0.081371 16.140 3E(5-0),BFP(-5.000),PRV(-8. 000),BaIV(7-0),T(9-0) LHS,©M.E.P.CAD,Inc. di AutoSPRINK2018 v14.1.4.0 2 3/29/2018 12:4 8:10PM Page 7 Job Name: GORDON/MASON RESIDENCE Remote Area Number:2 Date:3/29/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) Pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (0) Actual ID Length Total (psi) Friction(Pf) directly to(Pf)and shown as (Foot) (Foot) a negative value. 2 17-11 2 (See 135-0 150 36.572 Notes) 18-7 7.758 0.024186 E(5-10),T(11-8),GV(1-2),S 1 0 0 52.12 1.9590 153-7 3.715 0.00 48.045 Hose Allowance At Source 1 52.12 Total(Pt) Route 1 mom 202 38-9 4.9 26.52 3A (See 0-6 150 29.284 Route 2 Notes) - Sprinkler, 2-0 -0.208 — 19 39-3 26.52 0.8110 2-6 0.508077 1.260 E(2-0) 19 39-3 1 (See 0-6 150 30.336 Notes) 8-0 17 39-3 26.52 1.0550 8-6 0.141131 1.200 T(8-0) 31.535 Total(Pt) Route 2 &©M.E.P.CAD,Inc. di AutoSPRINK2018 v14.1.4.0 2 3/29/2018 12:48:10PM Page 8 Job Name: GORDON/MASON RESIDENCE Remote Area Number:2 Date:3/29/2018 [Equivalent Pipe Lengths of Valves and Fittings(C=120 only) r—IC Value Multiplier II Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90°Elbow EE 45°Elbow Eel 1114° Elbow Ee2 221A°Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap LHS,©M.E.P.CAD,Inc. di AutoSPRINK2018 v14.1.4.0 2 3/29/2018 12:48:10PM Page 9 VAIL VALLEY FIRE SPRINKLER CORPORATION 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970)914-5014 GORDON - MASON RESIDENCE 5185 MAIN GORE DRIVE VAIL, CO 81657 3/29/2018 EQUIPMENT SUBMITTAL ria �� FIRE PROTECTION DESIGN,INC. 13147 BIRCH WAY,THORNTON,CO 80241(363)920.0941 PAUL D.HUBBARD-NICET III-#108221 WorldwideFire Protectionrtijci7 Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and D r yPipe Systems General The Series LFII Residential Concealed Pendent Sp rinklers (TY3596) has Description been designed with heat sensitivity and water distribution characteristics TYCO RAPID RESPONSE Series LFII proven to help in the control ofresiden- - Residential 4.9K Concealed Pendent tial fires and to improve the chance for Sp rinklers (TY3596) are decorative, occupants to escap eor be evacuated. fast response,fusiblesolder sp rinklers The Series LFII Residential Con- 0111111 � designed for use in residential occu- cealed Pendent Sp rinklers(TY3596) p ancies such as homes, apartments, are ship p ed with a Disposable Pro- dormitories,and hotels. tective Cap. The Protective Cap is The cover p late assembly conceals temp orarily removed for installation, the sp rinkler operating components and then it can be rep laced to help above the ceiling.The flat profile of the p rotectthe sprinkler while the ceiling NOTICE cover p lateprovides the op timumaes is being installed or finished. The tip of thetically ap p ealingsp rinkler design. the Protective Cap can also be used The Series LFII Residential Concealed In addition, the concealed design of to mark the center of the ceiling hole Pendent Sprinklers(TY3596)described the Series LFII Residential Concealed into p laster board, ceiling tiles, etc. herein must be installed and main- Pendent Sprinklers(TY3596)provides by gently pushing the ceiling p roduct tained in compliance with this docu- 1/2 inch(12,7 mm)vertical adjustment. against the Protective Cap.When the ment and with the applicablestandards This adjustment provides a measure of ceiling installation is complete the Pro- of the National Fire Protection Associa- flexibility when cutting fixed sprinkler tective Cap is removed and the Cover tion(NFPA),in addition to the standards drops. Plate Assembly installed. of any authorities having jurisdiction. Failure to do so may impair the perfor- The Series LFII Residential Concealed Dry Pipe System Application mance of these devices. Sprink lers are intended for use in the The Series LFII Residential Concealed following scenarios: Pendent Sprinklers offers a laboratory The owner is responsible for main- approved option for designing dry p ip e taining their fire protection system • wet and dry p ip eresidential sp rin- residential sprink lersystems,whereas, and devices in proper operating con- kler systems for one-and two-fam- most residential sprink lers are lab ora- dition.Contact the installing contrac- ily dwellings and mobile homes per tory approved for wet systems only. tor or product manufacturer with any NFPA 13D questions. Through extensive testing, it has been • wet and dry pipe residential sprinkler determined that the number of design Sprinkler systems for residential occupancies sp rinklers(hydraulic design area) for p up to and including four stories in the Series LFII Residential Concealed height p erNFPA 13R Pendent Sp rinklers (TY3596) need Identification • wet and dry p ip esprink ler systems not be increased over the number of w for thearesidentialrypepinker s any design sp rinklers (hydraulic design Number (SIN) Occup ancyp erNFPA r3 area)as sp ecifiedforwet pipe sprinkler systems,as is accustomedfordensity/ TY3596 area sp rinkler systems designed per NF PA 13. Consequently,the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in IMPORTANT addition to not having to increase the Always refer to Technical Data number of design sprinklers(hydraulic Sheet TFP700 for the "INSTALLER design area)for systems designed to WARNING" that provides cautions NFPA 13, 13D, or 13R. with respect to handlingand instal- lation of sprinklersystemsand com- ponents. Improper handling and installation can permanentlydamage a sprinkler system or its compo- nents and cause the sprinklerto fail to operate in a firesituation or cause it to operate prematurely. Page 1 of 6 FEBRUARY 2015 TFP442 TFP442 Page 2 of 6 BODYf If SEALING WRENCH (1/2" NPT) ASSEMBLY RECESS _�, �1 ���""\ CAP I r'�/ ,`,�ir� ' SPRINKLER ��IWRENCHING thit AREA SADDLEger SUPPORT / 5 PUSH WRENCH COMPRESSION IN TO ENSURE CUP WITH SCREW n ENGAGEMENT ROLL FORMED I WITH SPRINKLER THREADS WRENCHINGAREA — - LEVER FIGURE2 D R W-TYPE 18 GUIDE ISPRINKLER WRENCH PIN 1 m F J m 1 1 SOLDER LINK ELEMENT GUIDE PIN HOUSING _ DEFLECTOR (OPERATED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO I I RETAINER SUPPORT THREAD CUP UNTIL ) I DIMPLES MOUNTING ls O O I. SURFACE IS FLUSH WITH CEILING EJECTION SPRING / - SOLDER' COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENTSPRINKLER(TY3596) 2-1/2" DIA. SPRINKLER- (63,5mm) 1/2" (12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER -/ ASSEMBLY NPT ADJUSTMENT FITTING ' OPERATED �' _ .. 1k/ SPRINKLER i —1 7/8"t1/4„ COVER JJ PLATE I (47,6 mm_ RETAINER 1/8" GAP ±6,4 mm) (3,2 mm) - II m _ I .--_-__-- COVER- SPRINKLER- 7/8 (22,2mm) IPII RETAINER SUPPORT CUP MOUNTING 1-1/8" (28,6 mm) ASSEMBLY ASSEMBLY 3/16 SURFACE , LI (4,8 mm) -���� 3-3/16" DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Design Criteria Dry Pipe System Water Delivery When using the Series LFII Residen- Data tial Concealed Pendent Sp rinklers TYCO RAPID RESPONSE Series LFII (TY3596)in dry pipe sprinkler systems, Residential Concealed Pendent Sp rin- the time for water delivery must not Approvals klers(TY3596)are UL and C-UL Listed exceed 15 secondsforthe most remote UL and C-UL Listed for installation in accordance with this NYC Approved under MEA 44-03-E-2NSF operating sprinkler. Certified to NSF/ANSI 61 section. The TYCO RAPID RESPONSE Series LFII Note: When conditions exist that are Obstruction to Residential Concealed Pendent Sp rinklers outside the scope of the provided cri Water Distribution are only Listed with the Series LFII Con- feria,ref erto the Residential Sprinkler Sprink lers are to be located in accor cealed Cover Plates having a facto ry-ap- Design Guide TFP490 for the manu- dance with the obstruction rules of p liedfinish. facturer's recommendations that may NFPA 13D, 13R, and 13 as applicable Cover Plates can be ordered by following be acceptable to the authority having for residential sprinklers as well as with the instructions in the Ordering Procedure jurisdiction. the obstruction criteria described within section. the Technical Data Sheet TFP490. Maximum Working Pressure System Types Operational Sensitivity 175 p si(12,1 bar) Per the UL Listing, wet p ip eand dry The sprink lers are to be installed rela- p ip esystems may be utilized. Per the p Discharge Cp,efficient C-UL Listing, only wet p ip esystems tive to the ceiling mounting surface as K=4.9 gp m/p SI' (70,6 Ipm/bar1t2) may be utilized. shown in Figure 3. TemperatureRating Refer to Technical Data Sheet TFP485 Sprinkler Spacing 160°F (71°C)Sp rinklerwith about the use of residential sprinklers in The minimum sp acing between sp rin- 139°F (59°C)Cover Plate residential dry p ip systems. klers is 8 feet (2,4 m). The maximum Vertical Adjustment CeilingTypes sp acing between sp rinklers cannot 1/2 inch(12,7 mm) yp exceed the length of the coverage area Smooth flat horizontal, or beamed, or n hydraulically sloped,in accordance with the 2013 (Ref.Table A or B) being ydraulicall y Refer to Ordering Procedure section. Edition of NFPA 13D, 13R, or 13 as calculated(e.g.,maximum 12 feet fora Physical Characteristics applicable. 12 ft.x 12 ft. coverage area,or 20 feet Body Brass fora 20 ft.x 20 ft.coverage area). Cap Bronze Hydraulic Design The Series LFII must not be used Saddle Brass (NFPAI3D and 13R) in applications where the air pres- Sealing Assembly Beryllium Nickel For systems designed to NFPA 13D sure abovethe ceiling is greater than w/TEFLON or NFPA 13R, the minimum required that below. Down drafts through the Soldered Link Halves Nickel sp rinkler flow rates are given in Support Cup could delay sprinkler Lever Bronze Tables A and B as a function of tern- Compression Screw Brass p erature rating and the maximum operation in a fire situation. Deflector Copper or allowable coverage areas. The Brass sp rinkler flow rate is the minimum Guide Pin Housing Bronze required discharge from each of the Guide Pins Stainless Steel total number of"design sprinklers"as or Bronze specified in NFPA 13D or NFPA 13R. Support Cup Steel The number of "design sp rinklers" Cover Plate Copper specifiedin NFPA13D and 13R forwet Retainer Brass pip esystems is to be applied when Cover Plate designing dry pipe systems. Ejection Spring Stainless Steel Hydraulic Design Operation (NFPA 13) M For systems designed to NFPA 13, the When exp osedto heat from a fire,the number of design sp rink lers is to be Cover Plate,which is normallysoldered the four most hydraulically demanding to the Support Cup at three points,falls sprink lers.The minimum required dis away to expose the sprink lerassemb ly. charge from each of the four sp rinklers At this point the Deflector supported by is to be the greater of the following: the Arms drop sdown to its operated • the flow rates given in Tables A and position. The fusible link of the sp rin- B as a function of temp erature rat- kler assembly is comprised of two link ing and the maximum allowable cov- halves that are soldered together with erage area a thin layer of solder.When the rated • a minimum discharge of temperature is reached, the solder 0.1 gp m/ft.2 over the design area melts and the two link halves sep arate comp rised of the four (4) most allowing the sp rinklerto activate and hydraulically demanding sp rinklers flow water. for actual coverage areas protected by the four(4)sp rinklers The number of design sprinklers sp eci- fied in NFPA13 forwet pipe systems is to be applied when designing dry p ip e systems. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure" Maximum Maximum Coverage Ordinary Temp.Rating Area' Spacing 160°F (71°C) Minimum Ft.x Ft. Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (ham) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed 16 x 16 16 13 7.0 Ceilings per 8 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2 4) 13R,or 13. Installed in 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hy draulicdesign criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hy draulicDesign under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE A W ET PI PE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENTSPRINKLER(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure2'3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area Ft 160°F (71°C) Ft.x Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed 16 x 16 16 15 9.4 Ceilings per 8 (4,9 x 4,9) (4,9) (56,8) (0,65) NFPA 13D or Concealed (2 4) 13R,or 13. Installed in 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hy draulicdesign criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hy draulicDesign under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation Step 6. Screw on the Cover Plate Care must be exercised to avoid Assembly until its flange comes in damage before,during,and afterinstal- TYCO RAPID RESPONSE Series LFII contact with the ceiling. lation. Sprinklers damaged by drop- Residential Concealed Pendent Sp rin- Do not continue to screw on the Cover ping, striking, wrench twist/slippage, klers (TY3596) must be installed in Plate Assembly such that it lifts a or the like,must be rep laced. accordance with this section. ceiling p anelout of its normal position. The owner is resp onsible for the General Instructions If the Cover Plate Assembly cannot inspection,testing,and maintenance of Damage to the fusible Link Assembly be engaged with the Mounting Cup their fire protection system and devices during installation can be avoided by or the Cover Plate Assembly cannot in compliance with this document, as handling the sprink ler by the support be engaged sufficiently to contact the well as with the applicable standards Aso- cup only(i.e.,do not app lypressure to ceiling, the Sp rinkler Fitting must be of the National Fire Protection on t the fusible Link Assembly). repositioned. ciation (e.g., NFPA 25), in addition to the standards of any other authorities A 1/2 inch NPT sp rinkleoint should be Care and having jurisdiction.Contact the install- obtained with a minimum to maximum ing contractoror product manufacturer torque of 7 to 14 lbs.-ft.(9,5 to 19,0 Nm). with any questions. Higher levels of torque may distort the Maintenance The owner must assure that the sp rin sp rinklerinlet with consequent leakage TYCO RAPID RESPO NSE Series LFII klers are not used for hanging any or imp airmentof the sprinkler. Residential Concealed Pendent Sp rin- objects and that the sprinklers are only Do not attempt to compensate for klers (TY3596) must be maintained cleaned by means of gently dusting insufficient adjustment in the Cover and serviced in accordance with this with a feather duster; otherwise,non- Plate / Retainer Assembly by under- section. operation in the event of a fire or inad- or over-tightening the Sprinkler. Read- vertent operation may result. just the position of the sprink lerfitting Before closing a fire protection system to suit. main control valve for maintenance Automatic sprinkler systems should be work on the fire protection system insp ected,tested,and maintained bya Step 1. The sprinkler must only be which it controls, permission to shut qualified Inspection Service in accor- installed in the pendent position and down the affected fire protection dance with local requirements and/or with the centerline of the sprinkler per- system must be obtained from the national codes. p endicularto the mounting surface. proper authorities and all personnel Step 2. Removethe Protective Cap. who may be affected by this action must be notified. Step 3. With p ip e thread sealant Absence of a CoverPlate may delay the applied to the pipe threads,and using the W-Type 18 Wrench shown in Figure sprinkler operation in a fire situation. 2, install and tighten the Sp rinkler/ When properly installed, there is a Support Cup Assembly into the fitting. nominal 1/8 inch (3,2 mm) air gap The W-Type 18 Wrench will accept a between the lip of the Cover Plate and 1/2 inch ratchet drive. the ceiling, as shown in Figure 3. This Step 4. Replace the Protective Cap by air gap is necessary for proper op era p ushing it upwards until it bottoms out tion of the sp rinkler by allowing heat against the Support Cup.The Protec flow from a fire to pass below and tive Cap help s p reventdamage to the abovethe Cover Plate to help assure Deflector and Guide Pins during ceiling appropriate release of the Cover Plate installation and/or during application of in a fire situation. If the ceiling is to be the finish coating of the ceiling. It may rep ainted after the installation of the also be used to locatethe center of the Sp rinkler,care must be exercised to clearance hole by gently p ushing the ensure that the new p aintdoes not seal ceiling material against the center point off any of the air gap. of the Cap. Factory p aintedCover Plates must not Note:As long as the protective Cap be repainted.They should be rep laced, remains in place, the system is considif necessary, by factory p ainted ered to be"Out Of Service." units. Non-factory app liedp aint may adversely delay or p revent sp rinkler Step 5. After the ceiling has been operation in the event of a fire. completed with the 2-1/2 inch (63 mm) Do not p ull the Cover Plate relative to diameter clearance hole and in p rep the Enclosure.Separation may result. aration for installing the Cover Plate Assembly, remove and discardthe Pro- Sp rinklers which are found to be tectiveCap,andverifythattheDeflec- leaking or exhibiting visible signs of tor moves up and down freely. corrosion must be rep laced. If the sprinkler has been damaged and Automatic sp rinklers must never be the Deflector does not move up and p ainted,p lated,coated, or otherwise down freely, replace the entire sprinkler altered after leaving the factory. Modi- assembly. Do not attemp tto modify or fied or over heated sprinklers must be rep aira damaged sprinkler. rep laced. Reim bid) Bulletin 048Rev. A Model RFS42 00 Residential Flat Concealed Horizontal Sidewall Sprinkler 00 (SIN RA4835) Coverage to 16 ft.x 20 ft.(4.9mx 6.1m) Features: 1. Flat cover plate(Solid or Perforated) for a flush, concealed wall finish. 2. 4.2(60 metric) K Factor. 3. Sized to fit in a 31/2" or larger stud space even when installed directly in a TorqueSafeTM 90° Sprinkler Head Elbow** and several other common 1/2" and 34" by 1/2" sprinkler fittings. 4. Push-on/pull-off flat cover plate. Application and Installation 5. Sprinkler shipped complete with factory installed The Model RFS42sprinklerisintended for installation nthe protective cap. residential portions of any occupancy in accordance with 6. Sprinkler assembly and cover plate packaged NFPA 13, 13R& 13D.The sprinkler is listed as a Concealed separately. Residential Horizontal Sidewall Sprinkler using a smooth, 7. 14" (3.2 mm)cover plate adjustment. flat, horizontal ceiling. System design and installation re- 8. Cover plate available, either solid or perforated, quirements for other ceiling configurations are described in in a wide variety of colors and finishes. NFPA 13, 13R or 130,as applicable. Listings & Approvals The minimum listed spacing between Model RFS42 sprin- klers is 8 ft(2.4 m). 1. Listed by Underwriters Laboratories Inc. and The low flow RFS42RES sprinklers are specifically engi- UL certified for Canada (cULus). neered to meet the latest residential sprinkler listing stan- UL Listing Category dards(UL 1626 Standard).* Residential Automatic Sprinklers The sprinkler must be installed and properly oriented with the Model G6 Wrench, as follows: UL Guide Number Do not remove the factory installed plastic protective cap VKKW since it is sized to fit inside the G6 wrench. Note that the sprinklercan only mate when the sprinkler's deflectororien- Patents: tation tab(Fig. 1) is aligned with wrench's key-way. The G6 U.S. Patent No.7,353,882, other Patents pending wrench is provided with bubble level pad and TOP mark- Product Description ing,to allow the proper orientation of the horizontal sidewall The Reliable Model RFS42 Concealed Residential Extend- deflector. Final leveling can be done after leak proof joint is ed Coverage Horizontal Sidewall Sprinkler is an attractive, obtained with a minimum to maximum torque of 8 to 18 ft-lbs concealed sprinkler assembly specially sized to fit within (11 to 24 N•m). Leave the protective cap on to protect the a 31/2" or larger stud space.The sprinkler uses a push-on/ sprinklerwhile the wall is plastered, wallpapered or painted. pull-off flat cover plate assembly. The sprinkler assembly is The protective cap must be removed and the listed cover shipped with a protective cap. plate installed prior to the sprinkler system being placed in The flat cover plate is attached to the skirt using 135°F service.A 25/8"(67 mm)diameterhole must be cut in the wall (57°C)ordinarytemperature classification solder. The sprin for the sprinkler assembly to extend through. kler is installed into the sprinkler fitting using the Model G6 Concealed cover plate/cup assemblies are listed only for Sprinkler Wrench. use with specific sprinklers. The use of any otherconcealed When the ambient temperature rises,the solder holding cover plate/cup assembly with the Model RFS42 Horizontal the cover plate melts,allowing the release of this part and Sidewall Sprinkler or the use of this dedicated concealed thus exposing the sprinkler inside to the rising ambient tem- cover plate assembly on any sprinkler with which it is not specifically listed will void all guarantees,warranties, listings perature. and approvals. This sprinkler is listed for a maximum service pressure of .175 psi(12,0 bar). * Effective date 3/14/2008 **Spears Manufacturing Company Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: "K"Factor Sprinkler Maximum Orifice Thread Maximum Water Identification Size US Metric Size Ambient Working Pressure Number Approvals Temperature (SIN) 3/3"(9.6mm) 4.2 60 1/2" NPT(R'/z) 100°F(38°C) 175 PSI(12 bar) RA4835 cULus Listed Design Criteria*** Max.Coverage Area Deflector to Ceiling Flow Rate Pressure Temperature Rating Width x Length Dimension ft.x ft. m x m inches mm gpm L/min psi bar Sprinkler Cover 12 x 12 3.6 x 3.6 4-6 102- 152 12 45.4 8.2 0.57 12 x 12 3.6 x 3.6 6- 12 152-305 13 49.2 9.6 0.67 14 x 14 4.3x4.3 4-6 102- 152 12 45.4 8.2 0.57 14 x 14 4.3 x 4.3 6- 12 152-305 14 53.0 11.1 0.78 165°F (74°C) 135°F(57°C) 16 x 16 4.9x4.9 4- 12 102-305 16 60.6 14.5 1.01 16 x 18 4.9 x 5.5 4- 12 102-305 18 68.1 18.4 1.29 16 x 20 4.9 x 6.1 4-6 102- 152 22 83.3 27.4 1.92 16 x 20 4.9 x 6.1 6- 12 152-305 23 87.0 30.0 2.10 ***For NFPA 13 systems calculate for a minimum design density of 0.1 gpm/sf, but in no case go below the Listed Design Criteria Flow Rate and Pressure. Material Data Bronze Sprinkler Body,Spring Closure Cap,Yoke,Lever, Slide Pin,Slide Plate,Deflector,Set Screw Brass Cover Plate,Sprinkler Sleeve,Frame Arms Stainless Steel Push Spring, Ball,Load Screw,Rivet Copper Plated Steel Cover Plate Skirt Nickel Alloy Fusible Element Nickel Alloy coated with PTFE Adhesive Tape Sealing Washer 2"± 1/16"[51MM± 1.6MM] %r Af- CEILING //4 DEFLECTOR ORIENTATION DEFLECTOR ORIENTATION TAB TAB a,�' 4-3/8"TO 12-3/8" f [111 TO 314MM] /�� RECOMMENDED o o WALL HOLE 1111111 MI 1‘200171{W.'1 nil DIAMETER �,. &---------- SII ��� ���- 2-5/8" I I ,„.„. � �R�-4M0'-•"*) g �y!�, [66.7MM] I �__.r 4 PUSH ON/PULL OFF FLAT COVERPLATE TO 1/2"-14 NPT 3-5/16"[84.1MM] DIAMETER FRONT VIEW PUSH ON/PULL OFF FLAT COVERPLATE REMOVED - 3/16"[4.8MM] 1-3/8"±1/16" [34.6MM±1.6MM] *SEE LISTED DESIGN CRITERIA TABLE FOR FLOW RATE AND PRESSURE BASED ON DEFLECTOR TO CEILING DISTANCE. DEFLECTOR IS 3/8"[9.5MM]ABOVE CENTERLINE OF SPRINKLER. 04BFGOIG Fig.1 2. Installation Guide for 31/2" or Larger Stud Space R FS42R esidential Flat Cover Concealed Horizontal Sidewall Sprinkler SIN RA4835 CEILING CENTERLINE 1-3/8" �{ [35MM] ELBOW ,MINIMUM -- / � - -- CENTERLINE CENTERLINE OF 4-3/8"TO 12-3/8"* 2-5/8"[66.7MM] [111 MM-314MM] DIAMETER HOLE IN WALL LOCATE PIPE SUPPORT CLAMP WITHIN 1"[25MM] FROM SPRINKLER FITTING'S INLET = STUD A 048FG010 *SEE LISTED DESIGN CRITERIA TABLE FOR FLOW RATE AND PRESSURE BASED ON DEFLECTOR TO CEILING DISTANCE. DEFLECTOR IS 3/8"[9.5MM] ABOVE CENTERLINE OF SPRINKLER. Fig.2 Front View Attachment Method: Fig. 3: 1. Securely support pipe from adjacent stud. 2. Pipe support clamp shall be located within 1" [25 mm] of sprinkler fitting's inlet lip. 3. The center of the sprinkler fitting shall be located at a horizontal distance of 13/" [35 mm] or more from the stud (Fig. 3). 4. The sprinkler fitting shall be installed so that the rear of the sprinkler is 2" +/- 1/6" from the finished surface of the wall.Verifywall assembly dimensions prior to installation to ensure that the cover plate attaches to the sprinkler and seats against the finished wall surface(Fig. 1). ELBOW — MINIMUM 1-3/8"[35MM] 3-1/8" m,— [79MM] STUD— /.viU////.////.%////////////////1� WALL FINISH MATERIAL DIMENSIONS ON THIS FIGURE ARE BASED ROOM ON A SPEARS TORQUESAFETM 3/4"X 1/2"90° CENTERLINE SPRINKLER HEAD ELBOW(4207-101). 098FC03B DIMENSIONS MUST BE ADJUSTED IF OTHER FITTINGS ARE USED. Fig.3 3. 5. Maintenance Cover Plate Finishesco Model RFS42 Concealed Sprinklers should be inspected Standard Finish and maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammoniaor any other clean- White ing fluids. Remove dust by using a soft brush or gentle Special Application Finishes vacuuming. Replace any sprinkler or cover plate assem- Flat White Paint bly, which has been painted (other than factory applied) or Off White Paint damaged in any way. A stock of spare sprinklers should Black Paint be maintained to allow quick replacement of damaged or Custom Color Paint operated sprinklers. Prior to installation, sprinklers should Bright Brass be maintained in their original cartons and packaging until Bronze Chr used to minimize the potential for damage to sprinklers that Satin Chrome would cause improper operation or non-operation. Once Black Plating operated automatic sprinklers and cover plates cannot be reassembled and reused. New sprinklers of the same size, ")Other colors and finishes are available. Consult factory for details. type and temperature rating must be installed. A cabinet of Note:Paint or any other coatings applied over the factory replacement sprinklers should be provided for this purpose. finish will void all approvals and warranties. Model RFS42 Residential FlatCoverConcealed Horizontal Sidewall Sprinkler Specification Ordering Information Sprinklers shall be a UL listed as residential flat cover Specify: concealed horizontal sprinkler with RFS42 deflector and 1. Model RFS42Residential Sidewall adjustable cover plate for light hazard, interior, non- 2. Cover Plate Type:Solid or Perforated corrosive applications. Sprinklers to be of bronze frame 3. Cover Plate Finish construction with brass cover plate and copper alloy retainerflangeassembly.Watersealassemblyshallconsist Installation Wrench of a Teflon*coated Belleville spring washer and machined Model G6 Sprinkler Wrench brass cup containing no plastic parts.Method of attaching the cover plate to the sprinkler cup shall be a Push-on Installation Aid and Pull-off design allowing a 1/8" cover plate adjustment. A protective plastic cap is included for use during instal Sprinklersshall have a nominal K-factorof 4.2(60 metric), and 1" NPT thread. Sprinkler temperature rating shall lation. be 165°F (74°C)with a cover plate temperature rating of 135°F (57°C). Sprinklers shall be capable of a maximum coverage area of 16 ft. x 20 ft. (4.9 m x 6.1 m), with a minimum lateral spacing of 8 ft. (2.4 m). Rated working pressure shall be 175 psi (12,0 bar).A plastic protective cap shall be provided and factory installed onto the sprinkler cup to protect the sprinkler from damage,which could occur during construction before the cover plate is installed. Cover plate type: [Solid] [Perforated]. Cover plate finish: [White] [Custom Color—specify]. Residential Coverage Concealed horizontal sidewall sprinklers shall be Reliable Model RFS42.SIN RA4835(Bulletin048). *DuPont Registered Trademark The equipment presented in this bulletinis to be installed in accordanceAiththe latestpublished Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or othersimilarorganizations and alsowith the provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting life and propertyforover90 years,and are installed and serviced bythe most highly qualified and reputable sprinklercontractors located throughout the United States,Canadaand foreign countries. Manufactured b Reliable Automatic Sprinkler Co.,Inc. �s' Recycled ® (800)431-1588 Sales Offices �W Paper Reliable (800)848 6051 Sales Fax (914)829 204 2 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.04/15 P/N 9999970457 NIBCO www.nibco.com AHEAD OF THE FLOW® Revision 3/29/04 e s. All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings.Because of the accuracy of construction and design, copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings:Wrot Pressure;Cast Pressure;Wrot Drainage;Cast Drainage;Flanges; Flared Tube;Threaded Bronze;Insert Fittings for PEX;Barbed Insert Fittings for Polybutylene.Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH—NIBCO Fittings are made from highest quality raw materials available—Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper,7% Lead,3%Tin,and 9%Zinc per ASTM Specification B 584.Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIB CO fittings are produced to meet requirements of applicable standards wherever practicable. NIB CO brand wrot and cast fittings are manufactured in the U.S.A.and Mexico.The manufacturing plants at Stuarts Draft,VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. R WROT SOLDER JOINT FITTINGS—"Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME/ANSI B 16.22;Wrought Copper and Copper Alloy Solder Joint Pressure Fittings." 2. The dimensional, material and workmanship shall dimensions of Federal Specifications WW-F-406or meet the requirements of MSS SP-104;Wrought ASME Std. B16.24. Copper Solder Joint Pressure Fittings." CLASS 125—Material,workmanship and 3. The dimensional, material and workmanship of dimensions of flanges shall be in accordance with 5"-12" copper fittings shall meet the requirements MSS SP-106. of MSS SP-109 "Welded Fabricated Copper Solder CAST BRONZE THREADED FITTINGS— Joint Pressure Fittings." "Cast Bronze Threaded Fittings shall be in accordance 4. Certified to ANSI/NSF 61. with ANSI/ASME B16.15." CAST COPPER ALLOY SOLDER JOINT FITTINGS POLYBUTYLENE COPPER INSERT TYPE VALVES AND —"Cast Copper Alloy Solder Joint Fittings shall be in FITTINGS—"Wrot Copper Insert Fittings shall be accordance with ANSI Std. 816.18." manufactured per the following specifications: WROT DRAINAGE FITTINGS—"Wrot Drainage MSS SP 103 or ASTM F1380." Fittings shall be in accordance with ASME/ANSI Std. NIBCO Copper Tube Fittings are all produced to above B 16.29." Standards.To simplify,write your specifications to CAST COPPERALLOYSOLDER JOINT DRAINAGE read: "Copper Tube Fittings to be in accordance with FITTINGS—"Cast Copper Alloy Solder Joint Drainage specifications as outlined in NIBCO Catalog c cf 0602." Fittings shall be in accordance with ASME Std. WROT COPPER MEDICAL MEDICAL GAS SYSTEM B16.23." COMPONENTS—Wrot copper fittings that are to be CAST COPPER ALLOY FLARED TUBE FITTINGS—"Cast installed in medical gas applications shall be prepared in accordance with NFPA 99, Health Care Facilities Copper Alloy Flared Tube Fittings shall be in accor- dance with ASME/ANSI Std. B16.26. Gas and Vacuum Systems and the Compressed Gas Association,Pamphlet G4.1. Packaging shall CAST COPPER ALLOY FLANGES AND FLANGED be adequately protective and include labeling that FITTINGS— identifies the preparer and states that the product CLASS 150—Cast Copper Alloy Flanges and has been cleaned and bagged for oxygen or med gas service. Flanged Fittings shall meet the requirements of MSS SP-106 and/or the workmanship and For technical information and dimensions refer to the engineering section contained in this catalog. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 4 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com NIBCO www.nibco.com AHEAD OF THE FLOW° Revision 5/12/02 Copper Waterlubecontinued COPPER TUBE -TYPES, STANDARDS,APPLICATIONS, TEMPERS AND LENGTHS Commercially Available Lengths Tube Type Color Code Standard Application Nominal or Standard Sizes Drawn Annealed Type K Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Protection 10-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar 12-inch 12 ft.(3.7m) 12 ft.(3.7m) Fuel/Fuel Oil Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) HVAC — 100 ft.(30.5m) Snow Melting 11/4-inch&11/2-inch — 60 ft.(18.3m) 2-inch — 40 ft.(12.2m) 45 ft.(13.7m) Type L Blue ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 10-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Protection 12-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar Fuel/Fuel Oil Natural Gas Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) Liquified Petroleum(LP)Gas — 100 ft.(30.5m) HVAC 11/s-inch&11/2-inch — 60 ft.(18.3m) Snow Melting 2-inch — 40 ft.(12.2m) 45 ft.(13.7m) X Type M Red ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 12-inch 20 ft.(6.1m) N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft.(6.1m) N/A Waste Vent HVAC Solar ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 41/2-inch 20 ft.(6.1m) 20 ft.(6.1m)1 Refrigeration Natural Gas Coils: 1/2-inch to 15/2-inch — 50 ft.(15.3m)1 Liquified Petroleum(LP)Gas OXY Type K ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1m) N/A MED Green OXY/MED OXY/ACR TypeL ACR/MED Blue TypeG Yellow ASTM B 837 Natural Gas Straight Lengths: 3/2-inch to 11/2-inch 12 ft.(3.7m) 12 ft.(3.7m)1 Liquified Petroleum(LP)Gas 20 ft.(6.1m) 20 ft.(6.1m)1 Coils: 3/2-inch to 7/2-inch — 60 ft.(18.3m)1 100 ft.(30.5m)1 'Available as special order only. U.S.customaryunits in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 81 www.nibco.com SUSPENSION CLAMP FOR CTS PIPING ))557 SERIES EZGIideTM ITEM#SUBMITTE D JOB NAME SPECIFICATION LOCATION Sioux Chief 557 series suspension clamps are to be used where ENGINEER necessary to secure or suspend CTS piping in residential or commercial applications.Tube clamp has a split, ribbed design to allow for use CONTRACTOR after piping is run and to allow pipe to expand and contract. Clamps are PO# TAG compatible with CTS copper, PEX or CPVC tube. Clamps shall be IAPMO certified. 0 INSTALLATION Spread each side of the clamp and position clamp around the tube. • lb \ Use approved nail or screw in both of the provided holes to secure to stud member or structure. MATERIALS 557-2 557F4 F *Standard(ivory): high impact polypropylene E Plenum-safe(orange): polyvinylidene fluoride meets ASTM E8425/50 • with UL 94 V-0 rating 0 O — WORKING TEMPERATURE � � B c Standard(ivory): 140°F continuous; impact resistant to 0°F Plenum-safe(orange): -10°F- 140°F A SAFE WORKING LOAD D� Standard(ivory): 25 lbs. Plenum-safe(orange): 25 lbs. 1/2" and 3/4° models E . DIMENSIONS O O 557-2 557-3 557-4 557-5 557-6 557-7 I A:Tube size CTS 1/2" 3/4" 1" 11/4" 11/2" 2" B:Screw hole to 0.938" 1.108" 1.013" 1.188" 1.363" 1.663" c tube center A C:Overall height 1.703" 1.998" 2.019" 2.332" 2.639" 3.219" D:Overall depth 0.625" 0.675" 0.825" 0.975" 1.025" 1.125" E: Mounting hole 1.206" 1.409" 1.421" 1.827" 1.827" 2.436" D center-lines 1"-2"models F: Mounting tab 0.12" 0.12" 0.12" 0.15" 0.15" 0.15" wall thickness oO G: Hole diameter 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" Made in USA Create Item Number 557-A B e.g.557F3:Plenum-safe 3/4" CTS suspension clamp MATERIAL A SIZE B ❑ —=High-impact polypropylene ❑ 2=1/2"CTS ❑ F =Polyvinylidene fluoride ❑ 3 =3/4"CTS ❑ 4 =1"CTS ❑ 5 =11/4"CTS ❑ 6 =11h"CTS ❑ 7 =2" CTS Sioux Chief Sioux Chief Manufacturing Company I P:1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 10-16 TUBECLAMP FOR CTS PIPING II 559 SERIES ITEM#SUBMITTED JOB NAME SPECIFICATION LOCATION Sioux Chief 559seriestube clamps are to be used where necessary to ENGINEER secure CTS piping in residential or commercial applications. Tube clamp has a split,ribbed design to allow for use after piping is run and to allow CONTRACTOR pipe to expand and contract. Clamps shall be compatible with CTS copper, PO# TAG PEX or CPVC tube.Clamps shall be IAPMO certified. INSTALLATION Spread each side of the clamp and position clamp around the tube. Use approved nail or screw in both of the provided holes to secure clamp to stud member or structure. MATERIALS \s i Standard(ivory): high impact polypropylene ' Plenum-safe(orange): polyvinylidene fluoride meets ASTM E84 25/50 with UL 94 V-0 rating 559-2 SAFE WORKING TEMPERATURES *Standard(ivory): 140°F(continuous); impact resistant to 0°F Plenum-safe(orange): -10°Fto 140°F SAFE WORKING LOAD Standard(ivory): 25 lbs Plenum-safe(orange): 15 lbs 559F6 DIMENSIONS D 5592 559_3 559_4 5595 559_6 5597 A:Tube size (CTS) 1/z" 3/4" 1" 11/4' 11/2" 2" B:Overall height 1.021" 1.275" 1.535" 1.785" 2.034" 2.562" clir A B C: Overall length 2.415" 2.617" 2.821" 3.227" 3.421" 3.836" D:Overall depth 0.624" 0.675" 0.825" 0.975" 1.025" 1.125" F I J [ E: Mounting hole 1.624" 1.827" 2.233" 2.639" 2.843" 3.248" c • center-lines F: Mountingtab .603" .603" 0.12" 0.15" 0.15" 0.15" wall thickness G: Hole diameter 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" E cO Made in USA Create Item Number 559A B e.g.559F3:Plenum-safe 3/a"CTS tube clamp MATERIAL A SIZE B ❑ -=High-impact polypropylene ❑ 2=1/2"CTS ❑ F =Polyvinylidene fluoride ❑ 3 =3/4"CTS ❑ 4 =1"CTS ❑ 5 =11A"CTS O 6 =11/2 CTS ❑ 7 =2" CTS Sioux Chief Sioux Chief Manufacturing Company I P:1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 11-16 101 Loop Hanger for Copper Tube ir • Recommended for the suspension of stationary non-insulated copper tube lines • Conformswith Federal Specification WW-H-171 (Type10), Manufacturers Standardization Society(MSS)SP-58(Type10) RS ,-/ B A OD Material:Steel Finish:Copper Electroplated, Electrogalvanized rOuter Diameter Rod Size Static Load Part Number Pipe Size OD RS A B C F 1010050CP 1/2" 5/8" 3/8" 3 3/16" 1 5/8" 1 9/16" 180 Lb 1010075CP 3/4" 7/8" 3/8" 31/8" 13/8" 13/16" 1801b 1010100CP 1" 11/8" 3/8" 31/8" 1 5/16" 1" 1801b 1010125CP 1 1/4" 1 3/8" 3/8" 3 3/16" 1 1/4" 13/16" 180 lb 1010150CP 1 1/2" 1 5/8" 3/8" 3 5/8" 1 9/16" 15/16" 180 lb 1010200CP 2" 21/8" 3/8" 313/16" 17/16" 5/8" 1801b 1010250CP 2 1/2" 2 5/8" 3/8" 4 7/16" 1 11/16" 9/16" 200 lb 1010300CP 3" 31/8" 1/2" 511/16" 21/2" 15/16" 2501b 1010350CP 3 1/2" 3 5/8" 1/2" 6 7/16" 3" 1 9/16" 300 lb 1010400CP 4" 4 1/8" 1/2" 7 1/8" 3 7/16" 1 3/4" 360 lb 1010500CP 5" 5 1/8" 5/8" 9 1/4" 4 11/16" 2 5/16" 480 lb 1010600CP 6" 6 1/8" 3/4" 11 3/16" 5 3/4" 2 15/16" 630 lb WARNING Pentair productsshall be installed and used only as indicated in Pentair's product instruction sheets and training materials.Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative.Improperinstallation,misuse,misapplication or other failure to completelyfollow Pentair's instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ©2017 Pentair All rights reserved Pentair,CADDY,CADWELD,CRITEC,ERICO,ERIFLEX,ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners.Pentair reserves the right to change specifications without prior notice. It CADDY 0 PENTAIR SAMMYS® HORIZONTALMOUNT SIDEWINDERS° f orW oodnstalls HORIZONTALLY into the side of woodstructures easilyand quickly! I Not less than 2°nominal width • Product Featuresis M. O ° (1-1/2")up to 3-1/2°pipe;not less than 3"(2-1/2")nominal width 4"&5"pipe •No pr a-dr illing equir ed. ___.ter ..�....»�... I—/ A Floor Joist , •Quickto install using the Sammy branch lines.Minimum 3"from t Minimum 2-1/2"fr ombottom for Nut Dr IVerwith an 18V cordless bottomfor main lines.Exception:This drill/driver. r equir emenbhall not apply to 2"or if / thicker nailing str ipsr estingon top of / steel beams. •Saves time fr omtr aditional • methods. I,,, •Reduces installation cost. 1:1 •Made in the U.S.A. 0 0• ti Composite/Truss acur d Consult tr ussmanufactur dor recommended installation point. 1AI "Pr e-dr illingnay be r equir edor Model SWG 25-380(tools available on pg 10) CI Rod Part Screw Ultimate UL Test Box Case Approvals Model Size Number Descriptions Pullout(Ibs) Load(lbs) Qty Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 _i 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 125 I CL 125 y 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 , 3/8" 8021957 SWG20 1/4x2" 1725 (Fir) 1050 25 3/8" 8073925 SWG20-SS 1/4x2" 1725 (Fir) 850 25 125 #14 SW Red ®. 318" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver I 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Par t#8114910 VERTICAL HORIZONTAL 1.Insertthe appropriate nut driver into a 3/8"or 1/nortable drill. 1.Insertthe appropriate nut driver into a 3/8'or 1/2"portable drill. 2.Insertthe SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insertthe SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill shouldbe in a vertical position. unitin a horizontal position and at a rightangle to the structural member, begin installation. 3.Push the face of the nut driver tightto the member.When the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins free on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now read yto receive 1/4';3/8", 1/2"ormetric all threadrod,boltstock.(The 1/2'fiequires the#14SWred nut driver) 4.The unitis now readyto receive 1/4",3/8'ormetrical!threadrodor boltstock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 f ootlbs.formaximum Note:When installing SWDR,follow the above instructions,then add retainer nut pulloutin puffin steel. and torque t ,,, o 20 footlbs.formaximum pulloutin purlin steel. sssss 1,..,vi Ill el. 1 .,„, , , _ : , 7 , ,,,, 4p; "A., SPECIAL NUT DRIVER SYSTEM:The nut driver slier edesigned with a unique spin-offfeature which pr ovidesa fast and safe installation each time.When the face of the dr ivercomes into contact with the mater ialyou are installing into,continue dr illing until nut dr iverspins free.Installation is then complete.Warranty requires the use of the appropriate nut dr iverfor installations. 5 Tofind a distributornear you,call 800-BUILDEX ZVRN® Model 500XL Water Pressure Reducing Valve WILKINS with Integral By-pass Check Valve Application Ideal for use where Lead-Free"valves are required.Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure.The high flow capacity aet9M LOW-LEAD makes this device most suitable for industrial water lines and O LEAD FREE commercial irrigation systems.The direct acting integral by- pass designprevents buildupof excessive systempressure .� Ili. 9 Y tr: -��: a��� C ® Certified to caused by thermal expansion.The balanced piston design ...... NSF ANSI 6+ enables the regulatorto react in a smooth and responsive - manner to changes in system flow demand,while at the same time,providing protection from inlet pressure changes. Options(Suffixes can be combined) ❑ - standard with single union FNPT inlet x F NPT Standards Compliance outlet(1/2"thru 2") and less union(21/2"&3") • ASSE® Listed 1003 (1/2" thru 2 1/2") ❑ C - copper sweat connection(1/2"thru 2") • IAPMO®Listed(1/2" thru 2") ❑ HR - 75 psi to 125 psi spring range,factory set • CSA®Certified(1/2" thru 2") at 85 psi(field set 2 1/2" &3") • City of Los Angeles Approved(1/2" thru 2") ❑ HLR - 10 psi to 125 psi spring range,factory set • NSF® Listed-Standard 61, Annex G" at 50 psi • Certified to NSF/ANS1372*by IAP MO R&T ❑HTSTSC- 180°F maximum temp,stainless steel trim, *(0.25%MAX.WEIGHTED AVERAGE LEAD CONTENT) spring,sealed cage ❑ L - less integral by-pass check valve(3/4"-2") Materials ❑ LPV - 180°F maximum temp with 10 psi to 35 psi Main valve body Cast bronze ASTM B 584 spring range,factory set at 20 psi Access covers Cast bronze ASTM B 584 ❑ LPC - 140°F maximum temp with 10 psi to 35 psi Low Lead Brass spring range,factory set at 20 psi Fasteners Stainless steel,300 series ❑ SC - sealed cage bell housing and stainless steel Stem&plunger Cast bronze ASTM B 584 adjustment screw Low Lead Brass ❑ SW - made for salt water service Elastomers Buna Nitrile(F DAapproved) ❑ YSBR - with lead-free bronze"Y"strainer on inlet EPDM(F DAapproved) ❑ 510XL - 400 psi inlet rating and 75 psi to 125 psi Cap gaskets Natural vulcanized fibre spring range,factory set at 85 psi Acetal(DelrinTM 500), NSF Listed (field set 2 1/2" &3") Springs Oil tempered wire,ASTM A 229 ❑ P - tapped and plugged for gauge Seat Stainless steel,300 series ❑ G - with 0-100 psi gauge included ❑ CPVC - CPVC tailpiece connection(3/4"-1") Features Sizes:1/2", 3/4",1", 1 1/4", 1 1/2", 2", 2 1/2", 3" Accessories Maximum working water pressure 300 psi ❑ Repair kit(rubber only) Maximum working water temperature 140° F Reduced pressure range 25 psi to 75 psi —D F actorypreset(field set 2 1/2" &3") 50 psi Z. Threaded connections(F NPT) ANSI 81.20.1 Copper connections(FC) ANSI B 16.22 la CPVC tailpiece:Max.hot water temp. 140°F @ 100 psi BNMI Cold water rated temp. 73.4°F @ 400 psi ii v + I s p WitioN$ C ` 5050=XL Dimensions&Weights(do not include p kg.) A DIMENSIONS(approximate) SIZE WEIGHT CONNECTIONS A B C D in. mm in. mm in. mm in. mm in. mm lbs. kg. 1/2 15 SINGLE UNION 4 1/2 108 6 152 1 5/8 41 2 3/4 70 3 1.5 3/4 20 SINGLE UNION 4 5/8 118 6 152 1 1/8 29 2 3/4 70 4 2.0 1 25 SINGLE UNION 5 1/8 130 6 7/8 175 1 5/8 41 3 5/16 84 6 3.0 1 1/4 32 SINGLE UNION 6 5/16 160 7 1/4 184 1 3/4 45 4 102 7 3.0 1 1/2 40 SINGLE UNION 8 5/16 211 10 254 1 7/8 48 5 127 14 6.5 2 50 SINGLE UNION 9 1/2 241 10 3/4 273 2 1/8 54 6 1/2 165 20 9.0 2 1/2 65 LESS UNION 10 254 14 1/2 368 3 76 8 203 28 12.5 3 80 LESS UNION 11 1/8 283 16 406 3 1/2 89 8 203 44 20.0 Zurn Industries,LLC I Wilkins Rev.C 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax805-238-5766 Date:10/13 In Canada I Zurn Industries Limited Document No.REG-500XL 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax905-405-1292 Product No.Model 500XL www.zurn.com Page 1 of 2 Flow Characteristics O Rated Flow(established by approval agencies) MODEL 500XL 1/2" THRU 3"(STANDARD& METRIC) FLOW R TES(I/s) 3.2 6.3 9.g 12.6 15.8 18.9 20 1 138 1/2" 3/4" 1" 11/2" 2" 21/2" 3" (7• 15 -(15mm)F (20mm, 25mm) 40mm 50mm) (65mm) - (80mm) 104 m LL 10 ' —_-- 69 1y - _ J• 5 ���� — X35 U. %/�_�� _ Lam 0 ) 0 50 100 150 200 250 300 "F low curves are based on a FLOW RATES(GPM) 50 psi pressure differential" Typical Installation Local codes shall govern installation requirements. Unless otherwise specified,the assembly shall be mounted in accordance with the manufacturers'instructions and the latest edition of the Uniform Plumbing Code.The assembly shall be installed with sufficient side clearance for testing and maintenance.The Model 500XL may be installed in any position.If installed in a pit,vault,or inside application, specify the"SC"sealed cage option.Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.:200 psi inlet reduced to 50 psi outlet). Caution:Anytime a reducing valve is adjusted,a pressure gauge must be used downstream to verify correct pressure set- ting. Do not bottom adjustment bolt on bell housing. MODEL 975XL2 Pim 3 •111, III=III,z RPZB CKFLOWPREVENTER I11-IT-IT=' _ III=III—I' OPT IONdLPRESSURE ,�� O ■IIIIIIIIII�I01' GdUGE 1 PROTECTIVEI �` 2 ■ MODEL 850XL — ¢ i,; i— ENCLOSURE SHUT-OFF VVLVE m = 1II�'u~4 i=i OPTION L ❑❑ PRESSUF�E GVUGE . ui UNITED BRASS WORKS, INC UNTITCD e ,/ 714 S. Main St.. Randleman, N.C. 27317 1509007 UKAS Phone: 800/334-3035 Fax: 800/498-4696 Registered ,,`4',<r;E,, 015 Model 80 Ball Valve - Double Female "Ai- (Complies with MSS-SP110-92) 9 40./.--i 4,,,,j 200 lbs. WSP @ 406 O Max 400 lbs. WOG* 100% Pressure Tested _ Threaded Ends* Blowout Proof Stem '/4" - '/2" Full Flow , , Y ` 3/4" - 2" Large Port Diameters ,k CRN OCO7135.2 *Contains Lead. Not Intended for Use in Potable Water Systems* F d 0o MATERIAL LIST ,, + , o . - NO. DESCRIPTION MATERIAL •mm 0 1 Lever Plated Steel w/vinyl grip t':: 3 5 2 Stem Brass .. 4 3 Jam Nut Plated Steel 4 Packing Nut Brass 'ice " 'Iluiili- 5 Packing Sleeve Brass Iill CD _ A 6 Packing Graphite Non-Asb. j�111111 7 Bevel Washer Steel %%// %-' y 8 0-Ring Buna Q 9 Tail Piece(1/4"- '/2") Brass m Tail Piece(3/4"-2") Bronze 10 10 Body Bronze C D 11 Ball Chrome Plated Brass B 12 Nest PTFE SHIP QUAN. SIZE A B C D E F WT.(lbs.) PER CTN. 1/4" 0.38 1.86 0.92 0.94 1.58 3.31 0.52 12 3/8" 0.38 1.86 0.92 0.94 1.58 3.31 0.52 12 ''/2" 0.50 2.17 1.06 1.11 2.28 4.23 0.78 12 3/4" 0.63 2.05 1.20 1.31 2.38 4.23 0.98 12 1" 0.81 3 .27 1.67 1.59 2.55 4.23 1.59 6 1 1/4" 1.00 3.48 1.72 1.77 3.19 5.47 2.47 4 1 '/2" 1.25 3.97 1.95 2.02 3.38 5.47 3.50 4 2" 1.50 4.41 2.14 2.27 3.56 5.47 5.00 2 ES-A-LF2000B Series LF2000B AMES Double Check Valve Assemblies FIREWATERWORKS Sizes: 1h — 2" (15 —60mm) LEAD FREE Features • Ease of maintenance with only one cover • Top entry r • Replaceable seats and seat discs • • Modular construction 410 • Compact design 3/a" LF2000B • 1/2" -2" (15-50mm)Lead Free" (20mm) cast silicon copper alloy body construction Series LF2000B DoubleCheck Valve Assemblies shall be installed at referenced cross- • Top mounted ball valve test cocks connections to prevent the backflow of polluted water into the potable water supply.Only • Low pressure drop those cross-comections identified by local inspection authorities as non-health hazard • No special tools required shall be allowed the use of an approved double check valve assembly. • 1/2" -1" (15-25 mm) have Check with local authority having jurisdiction regarding vertical orientation,frequency of tee handles testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std.C510 and are approved by the Foundation for Cross-Comection Controland Hydraulic Research at the Available Models University of Southern California.The LF2000B features Lead Free"construction to com- ply with Lead Free"installation requirements. Suffix: B- Quarterturn ball valves Specifications LBV- less ball valves A DoubleCheck Valve Assembly shall be installed at each noted location.The Double Check Valve Assemblies shall be constructed using Lead Free"materials. Lead Free" valves shall comp lywith state codes and standards,where applicable, requiring reduced Pressure — Tem erature lead content.The assembly shall consist of two positive seating check modules with l� captured springs and rubber seat discs.The check module seats and seat discs shall be Temperature Range:33°F-140°F replaceable.Service of all internal components shall be through a single access cover (0.5°C-60°C) secured with stainless steel bolts.The assembly shall also include two resilient seated iso- Maximum Working Pressure: 175psi lation valves and four top mounted, resilient seated test cocks.The assembly shall meet (12.06 bar) the requirements of ASSE Std. 1015 and AWWAStd.C510. Approved by the Foundation for Cross-Comection Control and Hydraulic Research at the University of Southern Cali- fomia.Assembly shall be an Ames Company Series LF2000B. Standards Approvals AWWAStd. C510, IAP MO PS31 OSSIFj c�p4o "The wetted surface of this product u p C ® US c us contacted by consumable water 1015 B64.5 3/4"-2" contains less than 0.25%of lead by (LBV Models Only) weight. Approved bythe Foundation for Cross-Connection Control and Hydratlic Research at the University of Southern California. LBV models not listed. Horizontal and vertical"flow up"approval on all sizes. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are appro timate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify prodict design,construction,spedfications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfi rewater.com Dimensions - Weights Nikk A 1� ....... - mm 1.--.11.. 0,11 ® -� 0 ��•I1�11"-)� F H` I ---- LF20008 G SIZE(DN) DIMENSIONS WEIGHT A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 12 15 10 254 4% 117 27A6 62 5 127 3% 85 2516 59 2'/6 52 4.5 2 3/4 20 111/2 282 4 102 3'/e 79 63/6 157 37/6 87 21/s 54 15/6 33 _ 5 2.3 1 25 131/4 337 5% 130 4 102 712 191 3% 85 11 Y1s 43 111/6 43 12 5.4 11/4 32 16% 416 5 127 35/16 84 91/ 241 5 127 3 76 2 50 15 6.8 112 40 163/4 425 4% 124 312 89 93/4 248 513/6 148 31/s 79 211/6 68 15.86 7.2 2 50 191/2 495 614 159 4 102 13% 340 6%6 156 37/s 87 211/6 68 25.75 11.7 Strainer sold separately Capacities kPa psi A 11/4"(32mm) As comp iledfrom documented Foundation for Cross-Connection Control 96 14 and Hydraulic Research at the Universityof Southern California lab tests. 0 83 12 to *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) 0 69 10 55 8 kPa psi 1/2"(1517 m) _ 41 6 N 83 12 y 28 4 O 69 10 E 14 2 °°°'- -i 55 80. 0 0 • 41 6 y 28 4 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm co U) 14 2 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 0. 0 0 5 7.5 10 15 fps 0 2 4 6 8 10 12 gpm 1.5 2.3 3.0 4.6 mps AP 0 7.6 15.2 22.8 30.4 38 45.61pm Flow Rate 5 7.5 10 fps 1.5 2.3 3.0 mps kPa psi 11/2"(40mm) Flow Rate 83 12 kPa psiA 3/4"(20mm) u) 69 10 0152 22 0 55 8 co 41 6 J 124 18 2 28 4 i 96 14 y 14 2 w 69 10 d 0 0 y Il Apo 10 20 30 40 50 60 70 80 90 100 110 120 gpm a 41 6 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 14 2 �� 5 7.5 10 15 fps 0 5 10 15 20 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps AP 0 19 38 57 76 95 114 133 152 171 190 Ipm Flow Rate 7.5 15 fps 2.3 4.6 mps kPa psi 0 2" Flow Rate 1n 83 12 kPa psi "(25mm) cn N 110 16 w J 69 10 A 1 55 8 J 83 12 3 8 41 6 • 69 10 3 55 8 y 28 4 N 41 6 214 2 LD 28 4 { 0 0 0- 14 2 - 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 5 7.5 10 15 fps AP 0 19 38 57 76 95 114 133 152 171 190 209 2281pm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate �a C OUILO%,� �� c A M E S9001-2008 FIRE a WATERWORKS' www.amesfirewater.com ,MeMet�^ CERTIFIED A Watts Water Technologies Company USA: Backflow- Tel:(916)928-0123 •Fax:(916)928-9333 Control Valves- Tel:(713)943-0688•Fax:(713)944-9445 Canada: Tel:(905)332-4090•Fax:(905)332-7068 ES-A-LF2000B 1322 ©2013 Ames Fire&Waterworks P VSR-F POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC and CSFMListed,FM and LPCB App roved,NYMEA Accep ted,CE Marked Service Pressure: Up to 450 PSI(31 BAR) Minimum FlowRatef or Alarm:10 GPM(38 LPM) Maximum Surge: 18 FPS(5,5 m/s) Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Sp ecirications: • Suitable for indoor or outdoor use with factory installed gasket and J die-cast housing. J • NEMA 411P54 Rated Enclosure-use with app ropriateonduit • �ANIP> fitting. • Temperaturdiange: 40°F/120°F,4,5°C/49°C • Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applicationsin explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40,sizes 2"thru 8" BS 1387 pipe50mm thru200mm Note: For copper or p lasticp ip euse Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 U.S.Pat.No.3921989 One or two family dwelling NFPA-13D Canadian Pat.No. 1009680 Residential occup ancy up to four stories NFPA-13R Other Patents Pending National Fire Alarm Code NFPA-72 Potter Electric,Rd., 1990 Optional:Cover Tamp erSwitch Kit,Stock No.0090018 GENERAL INFORMATION INSTALLATION: See Fig.2 The Model VSR-F is a vane type waterflow switch for use on wet These devices may be mounted on horizontal or vertical pipe. On sprinkler systems.It is UL Listed and FM Approved for use on steel horizontal pipe they should be installed on the top side of the pipe pipe;schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). where they will be accessible.The units should not be installed within LPC approved sizes are 2" thru 8" (50mm thru 200mm). 6" (15cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. The unit may also be used as a sectional waterfl ow detector on large systems. Drain the system and drill a hole in the pipeusing a circular saw in a slow speed drill.The 2" (50mm) and 2 1/2" (65mm) devices require a The unit contains two single pole,double throw,snap action switches hole with a diameter of 1 1/4"+ 1/8" - 1/16" (33mm±2mm).All other and an adjustable,instantly recycling pneumatic retard.The switches sizes require a hole with a diameter of 2" ±1/8" (50mm±2mm). are actuated when a flow of 10 gallons per minute(38 LPM) or more occurs downstream of the device. The flow condition must exist for a Clean the inside pipeof all growth or other material for a distance equal period of time necessary to overcome the selected retard period. to the pipediameter on either side of the hole. ENCLOSURE: The unit is enclosed in a general purpose,die-cast Roll the vane so that it may be inserted into the hole; do not bend or housing.The cover is held in place with two tamper resistant screws crease it.Insert the vane so that the arrow on the saddle points in the which require a special key for removal. A field installable cover direction of the waterfl ow. Install the saddle strap and tighten nuts tamper switch is available as an option which may be used to indicate alternately to an eventual 50 ft-lbs.(68 n-m)of torque(see Fig.2).The unauthorized removal of the cover. See bulletin no. 5400775 for vane must not rub the inside of the pipe or bind in any way. installation instructions of this switch. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT.#8800001-REV W PAGE 1 OF 2 MFG.#5400761-7/02 P VSR-F POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD — FIG.1 FIG.2 SWITCH TERMINAL CONNECTIONS OPTIONAL TAMPER SWITCH DO NOT LEAVE COVER OFF FOR CLAMPING PLATE EXTENDED PERIOD OF TIME TERMINAL RETARD ADJUSTMENT: � TIGHTEN NUTS TO CHANGE TIME TURN KNOB (EITHER DIRECTION) 1 Qui ,, ` FOR DESIRED TIME DELAY. USE THE MINIMUM iI� yli,%�` ALTERNATELY TO AN q>' AMOUNT OF RETARD NECESSARY TO PREVENT 77/� —0 EVENTUAL 5OFT.-LBS (68 n-m) OA FALSE ALARMS, A "B" SETTING IS USUALLY �p i,� OF TORQUE )1000„."„ „,, ;?,,,.. 0 ADEQUATE FOR THIS. FACTORY IS SET TO "B". �� OW' �� II fa TO INSTALL, DRILL HOLE AS INDICATED: ell G� PIPE SIZE HOLE SIZE \ \ �\ G��GG� Dwcn9z3a 2" to 2 1/2” 1 1/4" +1/8" —1/16" `�.✓7\ ��� MOUNT ON PIPE SO (50mm to 65mm) (33mm f2mm) Cb ARROW ON SADDLE et NmiIN CAUTION: OFINTS WATERFLOW DIRECTION 3" to 8" 2" ±1/8" An uninsulated section of a (8omm to 200mm) 50mm f2mm) single conductor should not ROLL PADDLE IN ,iiiii li lill be loop ed around the terminal Cover Tam er OPPOSITE DIRECTION p V OF WATERFLOW (with cover in place) and serve as two separate • • connections. The wire must be severed,therebyprovidingO O O DIRECTION OF WATERFLOW sup ervisionof the connection (WHT) (RED) (BLK) \ APPROX. RETARD SETTINGS (IN SECS.) in the event that the wire owe»a»,00,a, o ABODE becomes dislodged from under 0 10-25 20-40 35-55 50-70 60-90 the terminal. DWG. #761-30 FIG.3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG.4 1. The Model VSR-F has two To remove knockouts: Place 2 SETS OF NORMALLY switches, one can be used screwdriver at edge of knockouts, OPEN CONTACTS WATERFLOW ZONE EOLR FROM CLOSE ON ALARM ON FIRE PANEL FIRE PANEL to operate a central station, not in the center. i I proprietaryor remote signaling (1-^0 NO NC 11r111E �\�1® unit,while the other contact is 0 0 0 1k = = used to op crate a local audible or visual annunciator. 41 © ©NO © ®U®�® 2. A condition of LPC Approval of '� ❑� 0 17111-11171 M = NM this productis that the electrical THE N.C.ANDN.O.MARKINGS ON POSITIVE DC entry must be sealed to exclude THE SWITCH ARE FOR AN ALARM ORHOTAC Y CONDITION. BELL moisture. ( O �'� NEGATIVE DC OR r � g f� THE CONTACTS ARE REVERSED NEUTRALAC 3. For supervised circuits see Elf WHEN THE DEVICE IS IN THE O NORMAL CONDITION. OWGN 761-z "Switch Terminal Connections" drawing and caution note DWG./761-4 (Fig.1). APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges,trapped air,or short retard times,waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge A FFF,deluge,or chemical suppression systems. TESTING The frequency of insp ectionand testing for the model VSR-F and its associated protective monitoring system should be in accordance with app licableNFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve,that is usually located at the end of the most remote branch line,should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm(38 Lpm)is required to activate this device. IMPORTANT NOTICE: Please advise the p ersonresp onsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT.#8800001-REV W PAGE 2 OF 2 MFG.#5400761-7/02 le POTTER RBVS UNIVERSAL BALL The Symbol of Protection VALVE SWITCH UL and cUL Listed,FM,CSFM App roved Dimensions: (including mounting clamps) fQt7o:I k Large Clamps: 6"L x 5"W x 5.2"H ' — 15,2 cm Lx 12,7 cm W x 13,2 cm H .T. 1°nys 4_ Small Clamps: 6"L x 4"W x 5.2"H - 15,2 cm L x 10,2 cm W x 13,2 cm H - Weight: With Large Clamps:13.6 oz.(386,9 g.) With Small Clamps:11.0 oz.(311,2 g.) L I Enclosure: Non-Corrosive Comp osite Material i Environmental Limitations: illiLiiL4' I - NEMA 4 rated enclosure when p rop er electrical fittings are used.(IP67) • Temp eraturerange:-40°F to 150°F(-40°C to 65°C) Not for use in hazardous locations Housing Cover Tamp er: Activated by housing cover removal US Patent No.6,945,509 (Stock No. 1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC RBVS Stock No. 1000040(w/o Cover Tamper) 2A at 30 VDC RBVS-T Stock No. 1000035(w/Cover Tamper) SPDT Cover Tamper: 3A at 250 VAC General Installation On Lever Handle(See Fig.2) The Model RBVS is designed to monitor the fully op enposition of a ball valve 1. Select clamp sand clamp ingbolts based up on ip a/valvtsize,see Table 1. installed in a sprinkler system.The unit will fit on most ball valves installed on 2. Insert rubber clamp gripp ersinto clamps,see Fig.2. back-flow-preventers and alarm trim lines of dry,alarm,and deluge sprinkler 3. Place one clamp on top of pipe/ball valve near the valve handle and valves.The switch op eratesif the ball valve handle is moved from the op en insert clamp ingbolts through it. position.However,the switch does not track the position of the handle or ball. 4. Place other clamp over clamp ingbolts from beneath the installation and When the ball valve handle is in the op en p osition,a sp ring-loaded switch button thread hex nuts onto the clamp ingbolts,but do not fully tighten,(be sure will contact the valve handle.When the handle is moved from the op en p osition, hex nuts seat properly in clamp hex recesses).(NOTE:Some installations this switch button extends to the tripp edposition,and the RBVS contacts change may require one of the mounting bolts to be inserted from the bottom of state,thereby op ening or closing a circuit.A cover tamper switch is available and the brackets and then trimmed to allow the extension bracket to clear. is activated by the removal of the RBVS housing cover.If an attempt is made See Fig.4) to remove the RBVS by the removal of the mounting brackets,the unit will be 5. Attach extension bracket(if necessary to use for positioning)to top clamp set into the trip p edmode by this action. using'/4-20 X'/4"Hex bolt and washer,but do not fully tighten. The RBVS can be mounted to the hex portionof the ball valve or back-flow- 6. Attach"L"bracket(RBVS switch enclosure is loosely attached to"L" p reventeror to the adjoining pip evia two clamp s.The RBVS is shipp edwith two bracket)to extension bracket using''/4 20 X 3/4"Hex bolt and washer,but sets of mounting clamps to accommodate various pipeand valve sizes,refer to do not fully tighten. Table 1.An"L"shaped and offset bracket for mounting the switch enclosure and 7. Be sure ball valve is in the fully op en position. 8. Slide loosely assembled RBVS switch enclosure to a p ositionthatp ermits an extension bracket add to the mountingflexibility of the RBVS.See"Typical the switch button to contact the valve handle app roximatelyl" from its Mounting Diagram"and"Installation and Operation"on following page. inside end.See Fig. 1 for approximatelocation.Cut and remove the plastic Testing coating from the ball valve handle to allow the RBVS switch button to The RBVS and its associated protectivemonitoring system should be tested contact(and be activated by)the metal of the handle. in accordance with app licableNFPA codes and standards and/or the authority 9. Tighten clamp ingscrews alternately to an eventual 30 in-lbs.(minimum) having jurisdiction(manufacturer recommends quarterly or more frequently). of torque. 10. Maintain position of switch enclosure over valve handle and secure bolt Fig.1 Internal Components that holds the extension bracket to the clamping assembly.It may be NORMALLY OPEN necessary to close valve to access this bolt. 11. Position"L"bracket so that it contacts the back edge of the valve handle,and NORMALLY CLOSED �, secure its bolt.It may be necessary to close valve to access this bolt. COMMON i4- -t=:� 12. With the actuator fullyretracted,position RBVS switch enclosure to 1-102 _ ` .1 r= P..4 contact the valve handle squarely,see Fig. 1. ""� c' 13. With RBVS switch enclosure held s uarel in contact with valve handle, STRAIN RELIEFsquarely �� � i0 SWITCH BUTTON securely tighten the two tamper resistant screws on the backside of the ICOVERIrBLACK - N.O. `•40.4,1 ,L'„ 'm� LOCATION TAMPER L RED - N.C. �J ON HANDLE enclosure. WHITE - COMM 14. Close and op en the valve to verify op eration.The actuator should easily retract when the valve handle is in the open position. '-41 15. Fully open the valve. MOUNT SO 16. Remove the cover and wire main switch and tamperswitch if a licable. SWITCH BUTTONON A!. PLASTIC COATING pp IS APPROX. 1” FROM REMOVED FROM Carefully route tamp erswitch wires through strain relief channel in switch HANDLE INSIDE END BALL VALVE HANDLE enclosure.Fully seat the wires into the bottom of the channel.See Fig.1. INSWITCH BUTTON CONTACT AREA p securely17. Re laceRBVS switch enclosure cover and securel tighten cover screw. DWG #1086-1 Potter Electric Signal Company,LLC-2081 Craig Road,St.Louis,MO,63146-4161 -Phone:800-325-3936/Canada 888-882-1833-www.pottersignal.com PRINTED IN USA MFG.#5401086-REV U PAGE 1 OF 2 5/08 P POTTER RBVS UNIVERSAL BALL ® The Symbol of Protection VALVE SWITCH Fig.2 Typical Mounting Diagram Table 1 Clamp Sizing LEN6" GTH Pip e Valve/Size Clamp Clamp ing Bolts SWITCHL. 1/2"to 3/4"(12,5 to 19mm) Small 10-32 x 2 1/2 �� ENCLOSURE 7 j im 1"to 2"(25 to 50mm) Large 1/4-20 x 4" 1 "L" BRACKET it __ HEIGHT Switch Terminal Connections,Clamping Plate Terminal -=-7 Pli r EXT, BRACKET 0 5.2" cap 'w' Iwo (IF NECESSARY) -`�' �'o r, � .�0 A CAUTION 1111111.111CLAMPS A���O���� shAuldnotbed sopted roundt conductor l/ should not be loop ed around the terminalg . Mr /14-00 ■ oand serve as two se erateconnections.The pi 17CLAMPro�too�' DWOO 923-3 wire must be severed,thereby providing GRIPPERS sup ervisiomf the connection in the event WIDTH 4" (SMALL) — that the wire becomes dislodged from DWG #1086-2 5" (LARGE) under the terminal. Typical Electrical Connections LOCAL CIRCUIT TRANSFORMER OR BATTERY POWER STYLE D (CLASS A) SUPERVISED LOOP STYLE B (CLASS B) SUPERVISED CIRCUIT N.C. SIGNALING COM, COM, TO N,C, N,O, DEVICE N.C. N,C, UNIN,O. N.O. CONTTROL COM,• NO END-OF-LINE RESISTOR DWG. #1086-4 Tamper Switch Connections Fig.3 COVER TAMPER & RBVS CONNECTED COVER TAMPER & RBVS WIRED SWITCH ENCLOSURE TO THE SAME ZONE ON THE FACP TO SEPERATE ZONES COVER ` CM N,O,COM. D- TAMPER , OFFSET BRACKET COM, N.O. COM. •, / --°."'J FACP COVER EOLR N.C, TAMPER FACP EOLR FAC EOLR I ' N.O. ./`' ll' ® I ,I OWG.51086-5 at �. I- + Installation on Tee Handle(See Fig.3) �3 .„„„,..,,,i,„.. it) 'L"BRACKET .I 1. Select clamps and clamping bolts based upon pipe/valve size,see Table 1. � f G� -� 2. Insert rubber clamp grippers into clamps,See Fig.3. �,... V i„ 3. Place one clamp on top of pipe/ball valve near the valve handle and CLAMPS �'�+� 1. insert clamping bolts through it. L - 4. Place other clamp over clamping bolts from beneath the installation CLAMP GRIPPERS DWG X1086-3 and thread hex nuts onto the clamping bolts,but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "offset" bracket to the RBVS housing. Fig.4 6. Be sure ball valve is in the fully open position. (; -------,- it 7. Slide loosely assembled RBVS switch enclosure to a position that RBVS ®� permits the switch button to contact the valve handle approximately l 1/2"from the end of the handle.Cut and remove the plastic coating I J I from the ball valve handle to allow the RBVS switch button to contact (and be activated by)the metal of the handle. 8. Tighten clamping screws alternately and I/4-20 X 3/4"bolt to 30 in-lbs. (minimum)of torque. SOME INSTALLATIONS MAY 9. With the valve handle fully open, slide the RBVS housing down CAUSE INTERFERENCE BETWEENMOUNTING BOLTAND �_ _ until the switch operatesplus 1/8 inch.Tighten the screws holding1 p g OFFSET BRACKET.INSTALL BOLT A the RBVS to the"offset"bracket. FROM BOTTOM ANDTRIMAS��■ini ■ PIPE 10.Remove the RBVS switch enclosure cover. NEEDED TO CORRECT.11. Close and open the valve to verify operation.The actuator should easily retract up when the valve handle is in the open position. 12.Fully open the valve. \/ 13.Wire main switch and tamper switch(if applicable). Carefully route Irl tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. Dwca Ione-6 14. Replace RBVS switch enclosure cover and securely tighten cover screw. PRINTED IN USA MFG.#5401086-REV U PAGE 2 OF 2 5/08 ao0ou � �p TES —AN Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve C US APPROVED 3A ' 114" 112" TEST I a pusri • :� rnUOE �M • The AGF Manufacturing Inc. Model 1011A TESTANDRAIN matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system,with the added feature of an integral Model 7000 Pressure Relief Valve w ith drainage piping. • The Model 1011A comp lies with the requirements of NF PA-13 that stipulate a pressure relief valve be installed on all gridded systems and dow nstreamof all pressure reducing valves(see reverse). • The Model 1011A TESTANDRAIN is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses,and is 300 PSI rated. • Available in a full range of sizes from 3/4" to 2" NPT and BSPT, with all specifiable orifice sizes 3/4" (2.8K),7/16 (4.2K),1/2" (5.6K),17/32" (8.0K),5/8" (11.2K, ELO),3/4" (14.0K, ESFR),and K25 as required by NFPA 13, 2007 Edi- tion(see reverse). • The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-p iping outlet. • Ship ped w ith relief valve and bypass drain ports p lugged to expedite pressure testing the system. • A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including (1) adapter gasket,(1) ball,(2)valve seats,(1) stem packing,and (1) stem washerare avail- ab le for all TESTANDRAIN valves.Valve and orifice size must be specified w hen ordering. NOTE:It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90%and 105% of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability, Versatility, Code Compatibility TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS1011A 10/09 DR Moder L\ APPROVEDAP cous TANDRA Model 1011A 300 PSI Bronze Ball Valve,Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available DIMENSIONS MODEL 1O11A - FRONT VIEW Orifice Size Available: 3/8", 7A6", 1/2", 17/32", ELO(5/8")", ESFR(3/a")*, &K25"" A E I INLET SIZE A B C D E F G H rapa79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" TO F I3/4 (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) DRQ •� � I I: IM I. 1" 79A6" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8 H ( ■, (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) + 11/4 Ill o'2Z2:2:2�_,11611 715/16 111/16 29/16 41/4" 35/8" 115/16 59/16 51/2 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1 815/16" 113/16" 31/4" 51/18" 37/8" 25/8" 81/4" 107/8" MODEL 1O11A - PLAN VIEW 1/2 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815/16" 113/16" 31/4" 51/16 37/8" 25/8" 81/4" 107/8" .1 - A ► 2 (227 mm) (45 mm) (81.5 mm) 1 (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4" to 2" size units only -Available on 11/2" and 2" size units only DRAIN? (:;"1 ���,■ THE MODEL 1O11A PROVIDES ALL OF THE FOLLOWING... ~�I er �III-I ° ��. From the 2007 Edition of NFPA13 1 � I Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. T Chapter 8.16.2.4.2 Drain connections,interior sectional or floor controlvalve(s)- &8.16.2.4.3 shall be providedwith a drain connection having a minimum size as show nm Table 8.16.2.4.2. MATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle:Steel the flow of the drain. Stem: Rod Brass ChapterA.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into Ball:C.P. Brass a drain capable of accepting full flow...using an approved sight Body:Bronze test connection containing a smooth borecorrosion-resistant Valve Seat:Imp regnated Teflo if orifice giving a flow equivalent to one sprinkler... Indicator Plate:Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve:Bronze Chapter 8.17.4.2.4 shall be permitted to be installed in any location...downstream Bypass Fittings: Brass of the waterflow alarm. Bypass Tubing:Nylobraid Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed:(EX4019 Chapter 8.17.4.3.2 The trip test connection...w ith a shutoff valve and plug not less &EX4533) than 1", at least one of which shall be brass. FM Approved Chapter 7.1.2 -a gridded wet pipe system shall be providedwith a relief valve NYC-BSA No.720-87-SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than 1/2" in size shall be providedon the «-0, �, * 4, �"\ discharge side of the pressure-reducing valve set to operate at a ***** pressure not exceeding 175 PSI. �, Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the x��1� (pressure relief)valve MADE IN U.S.A. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: AG100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 FFax:610-240-4906 Architect:Engineer: www.testandrain.com Contractor: Talco Fire Systems Residential & Commercial Packaged Fire Pump Specialists Portland, Oregon LSF-500CIF Compact Residential Package 60GPM @ 60PSI r _A&_,, • System Specifications Motor -5 horsepower electric 1 -230 Volt, 21.5 Amp -Single Phase O�� g I 9 -3450 RPM O 3393 O 2 I II p O Pump -High pressure cast iron volute U �`�� -Machined bronze impeller -1%2" Suction -1%4" Discharge 1 4- " - -150 PSI Max Working Pressure Discharge Manifold -Check Valve �iiI=P lik -Zero to 100 PSI pressure gauge ,;-_ I, JNI-40/60 pressure switch -Isolation ball valve _phi ... Controls r li -230 Volt ill -Minimum run timer ' -Pressure switch operated contactor o o -HOA toggle switch (Hand, Off, Auto) iiu.iiljPhhhh1—431: = Dimensions (approximate) -22//6" Length -19%2" Height LIII 22 7 -14" Width 1 6 -135 pounds PerformancePerformance values based on multiple pump tests.Not for certification purposes. GPM 0 35 40 45 50 55 60 65 PSI 75 71 70 69 67 66 64 60 Phone: (800) 878-8055 www.talcofire.com Fax: (503) 688-1234