Loading...
HomeMy WebLinkAboutF18-0013_Approved Documents_1524497280.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Fire - Construction Permit F18-0013 Issued: 04/23/2018 TOWN OF VAIL Property Information Address: 354 BEAVER DAM RD N (210107113037 N) ( 210107113037 ) Unit #: N Parcel Number: 210107113037 Legal Description: Subdivision: VAIL VILLAGE FILING 3 Block: 2 Lot: 9 UNIT N Contacts Contact Type: Applicant Full Name: Steve Allen Address: 274 Center Drive Glenwood Springs, CO 81601 Phone: 7202190574 Contact Type: Property Owner Full Name: PRICE, KENT A. & ANDREA L. Address: Phone: None Contractor Contractor Type: Fire Protection Company: Western States Fire Protection Co. State License #: Phone: 303-549-8975 Project Information Project Name: 354 Beaver Dam Residences 2016 Project Description: Install Fire Sprinkler per NFPA 13D and Vail Fire Requirements Fees Paid Account #: 001-0000.31111.00 - Fire Suppression Permit Fee Fee Amount:$1,121.15 Account #: 001-0000.21123.00 - Fire Suppression Review Fee Fee Amount:$432.00 Total Paid:$1,553.15 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. FIRE PROTECTION HYDRAULIC CALCULATIONS AND MATERIAL CUT SHEETS FROM: 274 CENTER DRIVE GLENWOOD SPRINGS, CO 81601 (720)219-0574 FOR: PRIVATE DUPLEX 354 BEAVER DAM RD VAIL, CO. 81657 JOB# CH0357 SUBMITTED BY: STEVE ALLEN PROJECT MANAGER MARCH 21, 2018 Static - 133 Residual - 55.31 Flow - 1381 Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Bulletin 006 Rev. K February 2017 Product Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. Model RFC30, RFC43, and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and should be used with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and should be used with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43, and RFC49 sprinklers allow 1/2” (13 mm) of cover plate adjustment. Model RFC58 sprinklers allow 3/4” (19 mm) of cover plate adjustment. Model RFC cover plates are available in a variety of finishes as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or perforated cover plates. Sprinkler Model Nominal K-Factor gpm/psi1/2 (l/min/bar1/2) Max. Coverage Area ft x ft (m x m) Sprinkler Identification Number (SIN) RFC30 3.0 (43.2) 14 x 14 (4.3 x 4.3) RA0611 RFC43 4.3 (62) 20 x 20 (6.1 x 6.1) RA0612 RFC49 4.9 (70.6) 20 x 20 (6.1 x 6.1) RA0616 RFC58 5.8 (84) 20 x 20 (6.1 x 6.1) RA0613 Table A www.reliablesprinkler.com Model RFC43Model RFC30 Model RFC49 Model RFC58 Model RFC Cover Plate Solid Perforated Bulletin 006 Rev. K February 2017 Page 2 of 7 www.reliablesprinkler.com Model RFC30 Residential Sprinkler SIN RA0611 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43.2 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC30 Sprinkler Components and Dimensions Figure 1 Model RFC30 Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3.6 x 3.6) 9 (34) 9.0 (0.62) 14 x 14 (4.3 x 4.3) 10 (38) 11.0 (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Bulletin 006 Rev. K February 2017 Page 3 of 7 www.reliablesprinkler.com Model RFC43 Residential Sprinkler SIN RA0612 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC43 Sprinkler Components and Dimensions Figure 2 Model RFC43 Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3.6 x 3.6) 12 (45) 7.8 (0.54) 14 x 14 (4.3 x 4.3) 13 (49) 9.1 (0.63) 16 x 16 (4.9 x 4.9) 13 (49) 9.1 (0.63) 18 x 18 (5.5 x 5.5) 18 (68) 17.5 (1.21) 20 x 20 (6.1 x 6.1) 21 (79) 23.8 (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Model RFC49 Residential Sprinkler SIN RA0616 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (70.6 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC49 Sprinkler Components and Dimensions Figure 3 Model RFC49 Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 13 (49.0) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (75.7) 16.7 (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K February 2017 Page 4 of 7 www.reliablesprinkler.com Bottom View 16 X 16 SPACING @ .1 DENSITY = 25.6 GPM FLOW Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure Max. Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 16 (60.6) 7.6 (0.53) 18 x 18 (5.5 x 5.5) 18 (68.1) 9.6 (0.66) 20 x 20 (6.1 x 6.1) 20 (75.7) 11.9 (0.82) Bulletin 006 Rev. K February 2017 Page 5 of 7 www.reliablesprinkler.com Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Cover Plate Finishes(1) Table H Bulletin 006 Rev. K February 2017 Page 6 of 7 www.reliablesprinkler.com Sprinkler Model Cover Plate Model Cover Plate Diameter inch (mm) Recommended Hole Diameter in Ceiling inch (mm) Cover Plate Adjustment inch (mm) Min. to Max. Face of Fitting to Ceiling(1) inch (mm) Min. to Max. Dropped Deflector Distance below Ceiling inch (mm) Cover Plate Temperature Rating RFC30 RFC43 RFC49 RFC 3-5/16 (84) 2-5/8 (67) 1/2 (13) 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135°F (57°C) RFC58 RFC 3-5/16 (84) 2-5/8 (67) 3/4 (19) 1-1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 135°F(2) (57°C) or 165°F(3) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Table JInstallation Dimensions Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2” square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is 8 to 18 ft/lb (11 to 24 N/m). Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC43, and RFC49 sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC58 sprinklers are available in either ordinary or in- termediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC43, RFC49, and RFC58 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30 and RFC43 sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC43, RFC49, RFC58) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Bulletin 006 Rev. K February 2017 Page 7 of 7 www.reliablesprinkler.com Model FC Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Wrench P/N 9999970261 Series 2000B-FP Double Check Valve Assemblies shall be installed at referenced cross- connections to prevent the backflow of polluted water into the potable water supply. Only those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each not ed location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be re placeable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated gear operated slow close isolation valves and four resilient seated test cocks. The as sembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B-FP. Approvals Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Horizontal approval on all sizes. ES-A-2000B-FP 2000B-FP Series 2000B-FP Double Check Valve Assemblies Sizes: 1" – 2" (25 – 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1" – 2" (25 – 50mm) Cast bronze body construction • Low pressure drop • No special tools required • Gear operated, slow close shutoffs • Pre-wired tamper switch (2) per shutoff Pressure — Temperature Temperature Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 1015 B64.5 1" - 2" Job Name ________________________________________________ Contractor ______________________________________________ Job Location ______________________________________________ Approval _______________________________________________ Engineer _________________________________________________ Contractor’s P.O. No. ______________________________________ Approval _________________________________________________ Representative ___________________________________________ Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without in curring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. The information contained herein is not intend- ed to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before begin- ning the installation of this product. NOTICE Capacities As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) ∆P * kPa psi 110 16 83 12 69 10 55 8 41 6 28 4 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆P * kPa psi 96 14 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0∆P0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps * ∆P * kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm0 95 190 285 380 475 570 665 760 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1" (25mm) 11⁄4" (32mm) 11⁄2" (40mm) 2" (50mm) Dimensions – Weights Strainer sold separately Pressure LossPressure LossPressure LossPressure Loss Flow Rate Flow Rate Flow Rate Flow Rate MODEL SIZE DIMENSIONS WEIGHT A B C D E F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2000B-FP 1 25 131⁄4 337 41⁄2 114 31⁄2 89 1 25 71⁄2 191 53⁄4 146 27⁄8 73 27⁄8 73 143⁄8 365 12.2 5.5 2000B-FP 11⁄4 32 155⁄8 397 53⁄8 136 33⁄4 95 15⁄8 41 91⁄2 241 61⁄16 154 27⁄8 73 33⁄16 81 161⁄2 419 17.3 7.8 2000B-FP 11⁄2 40 163⁄8 416 55⁄8 143 4 102 15⁄8 41 93⁄4 248 61⁄4 159 27⁄8 73 33⁄8 86 17 432 19 8.6 2000B-FP 2 50 191⁄8 486 61⁄2 165 41⁄4 108 21⁄4 54 133⁄8 340 61⁄2 165 27⁄8 73 35⁄8 92 191⁄2 495 26.4 12 C H D G B F I A E ES-A-2000B-FP 1536 © 2015 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company NOTICE Inquire with governing authorities for local installation requirements 5 PSI LOSE @ 52 GPM Page 1 of 2 a company DOCUMENT #: REVISION: REG-500 6/06 Model 500 Water Pressure Reducing Valve with Integral By-pass Check Valve SPECIFICATION SUBMITTAL SHEET FEATURES DIMENSIONS & WEIGHTS (do not include pkg.) MATERIALS APPLICATION ACCESSORIES q Repair kit (rubber only) OPTIONS (Suffixes can be combined) q -standard with single union FNPT inlet x FNPT outlet (1/2" thru 2") and less union (21/2® & 3®) q C - copper sweat connection (1/2" thru 2") q HR - 75 psi to 125 psi spring range, factory set at 85 psi (fieldset 2 1/2® & 3®) q HLR - 10 psi to 125 psi spring range, factory set at 50 psi q HT-210°F maximum temp q L - less integral by-pass check valve (3/4®-2®) q LPV - 210°F maximum temp with 10 psi to 35 psi spring range, factory set at 20 psi q LPC - 180°F maximum temp with 10 psi to 35 psi spring range, factory set at 20 psi q SC - sealed cage bell housing and stainless steel adjustment screw q SW - made for salt water service q YSBR - with bronze "Y" strainer on inlet q 510 - 400 psi inlet rating and 75 psi to 125 psi spring range, factory set at 85 psi (fieldset 2 1/2® & 3®) q P - tapped and plugged for gauge q CPVC - CPVC tailpiece connection (3/4®-1®) Sizes: q 1/2" q 3/4" q 1" q 1 1/4" q 1 1/2" q 2" q 2 1/2" q 3" Maximum working water pressure 300 psi Maximum working water temperature 180° F Reduced pressure range 25 psi to 75 psi Factory preset (fieldset 2 1/2® & 3®) 50 psi Threaded connections (FNPT) ANSI B1.20.1 Copper connections (FC) ANSI B 16.22 CPVC tailpiece: Max.hot water temp. 180°F @ 100 psi Cold water rated temp. 73.4°F @ 400 psi Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The high flow capacity makes this device most suitable for industrial wa- ter lines and commercial irrigation systems. The direct act- ing integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion. The bal- anced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes. ¯ ASSE® Listed 1003 (1/2® thru 2 1/2® ) ¯ IAPMO® Listed (1/2® thru 3° ) ¯ City of Los Angeles Approved (1/2® thru 3° ) ¯ CSA® Certified (1/2® thru 2®) STANDARDS COMPLIANCE Main valve body Cast bronze ASTM B 584 Access covers Cast bronze ASTM B 584 Brass ASTM B 16 Fasteners Stainless steel, 300 series Stem & plunger Cast bronze ASTM B 584 Brass ASTM B 16 Elastomers Buna Nitrile (FDA approved) EPDM (FDA approved) Cap gaskets Natural vulcanized fibre Acetal (Delrin± 500), NSF Listed Springs Oil tempered wire, ASTM A 229 Seat Stainless steel, 300 series 500 WILKINS D B AC in. mm in. mm in. mm in. mm in. mm lbs. kg. 1/2 15 SINGLE UNION 4 1/2 108 6 152 1 5/8 41 2 3/4 70 3 1.5 3/4 20 SINGLE UNION 4 5/8 118 6 152 1 1/8 29 2 3/4 70 4 2.0 1 25 SINGLE UNION 5 1/8 130 6 7/8 175 1 5/8 41 3 5/16 84 6 3.0 1 1/4 32 SINGLE UNION 6 5/16 160 7 1/4 184 1 3/4 45 4 102 7 3.0 1 1/2 40 SINGLE UNION 8 5/16 211 10 254 1 7/8 48 5 127 14 6.5 2 50 SINGLE UNION 9 1/2 241 10 3/4 273 2 1/8 54 6 1/2 165 20 9.0 2 1/2 65 LESS UNION 10 254 14 1/2 368 3 76 8 203 28 12.5 3 80 LESS UNION 11 1/8 283 16 406 3 1/2 89 8 203 44 20.0 SIZE CONNECTIONS WEIGHTDIMENSIONS (approximate) A B C D Page 2 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) · Website: http://www.zurn.com TYPICAL INSTALLATION FLOW CHARACTERISTICS SPECIFICATIONS Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers² instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500 may be installed in any position. If installed in a pit or vault, specify the "SC" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). CAUTION: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing. VERTICAL INSTALLATION OPTIONAL PRESSURE GAUGE MODEL 850 SHUT-OFF VALVE DIRECTION OF FLOWMODEL 500 TO HANDLE LOW DEMANDS (SET @ 65 PSI) DIRECTION OF FLOWMODEL 500FC TO HANDLE HIGH DEMANDS (SET @ 55 PSI) BATTERY INSTALLATION TYPICAL INSTALLATION The Pressure Reducing Valve shall consist of a bronze body and bell housing, a separate access cover for the plunger and a bolt to adjust the downstream pressure. The bronze bell housing and access cap shall be threaded to the body and shall not require the use of ferrous screws. The assembly shall be of the balanced piston design and shall reduce pressure in both flow and no-flow conditions. The assembly shall be accessible for maintenance without having to remove the body from the line. The Pressure Reducing Valve shall be a WILKINS Model 500. MODEL 975XL RPZ BACKFLOW PREVENTER PROTECTIVE ENCLOSURE MODEL DU DIELECTRIC UNION OPTIONAL PRESSURE GAUGE 12" MIN. 30" MAX. DIRECTION OF FLOW FLOW RATES (GPM)FALL OFF (PSIG)0 5 10 15 0 100 200 300 69 104 6.3 12.6 18.9 FALL OFF (kpa)FLOW RATES (l/s) MODEL 500 1/2" THRU 3" (STANDARD & METRIC) 3/4" (20mm) 35 20 1381/2" (15mm) 1" (25mm) 1 1/4" (32mm) 1 1/2" (40mm) 2" (50mm) 2 1/2" (65mm) 3" (80mm) 50 150 250 3.2 9.5 15.8 5.5 PSI LOSE @ 52 GPM Agency Listings T-Tap Waterflow Detectors System Sensor T-Tap Waterflow Detectors are designed for primary signaling in residential systems and branch line signaling in larger systems. Features Sealed retard mechanism (Model WFDT)• Visual switch activation (Model WFDT)• Twelve different flexible plastic paddles• Vertical or horizontal mount• Durable, tamper-resistant enclosure• Dual SPDT switches in durable terminal block• Sizes marked on flexible plastic paddles• 100 percent synchronization activates both alarm panel and local bell• Accommodates up to 12 AWG wire• Both the WFDT retard model and the WFDTNR non-retard model fit any tee that has a 1˝ NPT branch, including: 1˝, 1¼˝, 1½˝ and 2˝ NPT threaded ferrous and brass tees; 1˝, 1¼˝, 1½˝ and 2˝ copper sweat tees; Tyco, Spears®, Victaulic® and NIBO brand 1˝ CPVC tees; and 1½˝ polybutylene tees. Design. The design of the WFDT and WFDTNR makes them easy to install and simple to maintain. Either can be mounted in the vertical or horizontal position. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism (Model WFDT only) and switch assemblies are field-replaceable. Features. Twelve different flexible plastic paddles fit 1˝, 1¼˝, 1½˝ and 2˝ tees. Sizes are marked clearly on the paddles for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw. The handy depth gauge ensures the proper installation depth and clearance of the detector to the tee. Construction. The WFDT and WFDTNR include a durable, tamper- resistant enclosure and rugged switch assembly. The robust covers completely enclose the electrical components to keep out dust and dirt. Improved self-guiding security screws and removal tools make the detectors resistant to tampering and simplify field maintenance. Dual SPDT switches are enclosed in a durable terminal block for added strength. S739 167-93-E7770-1653:114 CS169 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0195-013 • 1/09 • #1923 T-Tap Waterflow Detector Specifications Architectural/Engineering Specifications Model shall be a WFDT or WFDTNR as manufactured by System Sensor. T-tap waterflow detectors shall be installed on a tee that has a 1˝ NPT branch including: 1˝, 1¼˝, 1½˝ or 2˝ threaded ferrous or brass tee; 1–2˝ copper sweat tees; Tyco, Spears,® Victaulic,® and NIBCO brand 1˝ CPVC tees; or 1½˝ polybutylene tee as designated on the drawings and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate size, either a vertical or horizontal run at least 6˝ from any fittings or valves that may change water direction, flow rate, or pipe diameter or no closer than 24˝ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 250 psi. The retard t-tap detector shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism. The non-retard t-tap detector shall respond with no time delay to waterflow in the specified direction and range. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. All detectors shall be listed by Underwriters Laboratories for indoor or outdoor use. Physical/Operating Specifications Static Pressure Rating 250 PSI Operating Temperature Range 32°F to 120°F (0°C to 49°C) Maximum Surge 18 FPS Enclosure Rating UL indoor/outdoor rated Triggering Threshold Bandwidth (Flow Rate) 4–10 GPM Cover Tamper Switch UL models: optional P/N 546-7000 ULC/Canadian models: factory installed Overall Dimensions, Installed WFDT: 4.5˝ H × 3.75˝ W × 6.7˝ L (11.4cm H × 9.5cm W × 17cm L) WFDTNR: 3.75˝ H × 3.25˝ W × 4.25˝ L (9.5cm H × 8.2cm W × 10.8cm L) Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA 72 Contact Ratings Two sets of SPDT (Form C) 10.0 A @ 125/250 VAC 2.5 A @ 24 VDC Shipping Weight WFDT: 2.6 lbs. (1.2 kg.) WFDTNR: 1.5 lbs. (0.7 kg.) Compatible Tee Fittings Threaded ferrous and brass tees, copper sweat tees, CPVC tees, and polybutylene tees Warranty 3 years Conduit Entrances Two openings for ½˝ conduit. U.S. Patent Numbers 5,213,205 DELAYADJUSTMENTDIAL 55700154530TIME D ELAY IN SECON D SNUMBER O N DIAL IS APPROXIM A T E NOTE: RETARD TIME MAY EXCEED 90 SECONDS. ADJUSTAND VERIFY THAT TIME DOES NOT EXCEED 90 SECONDS.NUMBER ON DIAL IS APPROXIMATE TIME DELAY INSECONDS WITH AN ACCURACY OF +/³ 50%. Delay Adjustment Dial + + – – SSM24-X SSV120-X NOTE: COMMON AND B-NOCONNECTIONS WILL CLOSE WHEN VANE IS DEFLECTED, I.E.,WHEN WATER IS FLOWING. DUALSWITCHES PERMITAPPLICATIONS TO BE COMBINEDON A SINGLE DETECTOR. BREAK WIRE ASSHOWN FORSUPERVISION OF CONNECTION. DONOT ALLOWSTRIPPED WIRELEADS TO EXTENDBEYOND SWITCH HOUSING. DO NOTLOOP WIRES. POWER24VDC OR120VDC INITIATING LOOP UL-LISTED COMPATIBLE CONTROL PANEL CONTACT RATINGS 125/250 VAC 24 VDC 10 AMPS 2.5 AMPS SCHEMATIC OFINDIVIDUAL SWITCH IN“NO WATERFLOW” CONDITION SUGGESTED EOLRESISTOR B-NO COM A-NC Electrical Connections for WFDT Ordering Information UL Model ULC Model Description WFDT WFDTA Waterflow Detector, Fits 1˝, 1¼˝, 1½˝, 2˝ ferrous and brass threaded tees; 1˝, 1¼˝, 1½˝, 2˝ copper sweat tees; 1˝ CPVC tees; and 1½˝ polybutylene tees WFDTNR — Waterflow Detector, non-retard, fits same tees as Model WFDT Accessories Description A77-01-02 Replacement terminal block for WFDT A77-01-08 Replacement terminal block for WFDTNR A3008-00 Replacement retard mechanism PRK9 Replacement paddle kit – 12 paddles for WFDT and WFDTNR (see WFDT for sizes) 546-7000 Cover tamper switch kit for WFDT S07-66-02 Replacement tamper screws for covers of WFDT, WFDTNR WFDW Replacement tamper-proof wrench for cover of WFDT, WFDTNR WFDN4 NEMA-4 gasket kit C58-164-01 Replacement metal cover C58-195-01 Replacement plastic cover (WFDTNR) Spears® is a registered trademark of the Spears Manufacturing Company. Victaulic® is a registered trademark of the Victaulic Company of America. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 6 AHEAD OF THE FLOW® www.nibco.com Revised 5/2/2007 Fire Protection Valve • Threaded or Grooved Body Style • Full Port Design 1" - 2" • Standard Port Design 2¹⁄₂" • Accepts Internal Supervisory Switches MATERIAL LIST PART SPECIFICATION 1. Body Bronze ASTM B 584 Alloy C84400 2. Ball Chrome Plated Brass ASTM B 124 Alloy C37700 3. Seat Ring Carbon-filled TFE 4. Thrust Washer Reinforced TFE 5. Stem Bronze ASTM B 371 Alloy C69430 6. Stem O-Ring Nitrile 7. Retaining Washer Brass 8. Retaining Ring Steel 9. Ground Wire Screw Steel 10. 505-8 Act Assy. Brass 11. Body End Bronze ASTM B 584 Alloy C84400 12. Mounting Screw Steel 13. Lock Washer Steel 14. Handle Pin Brass 15. Hand Wheel Steel/plastisol coated (1¹⁄₄" -2¹⁄₂") Brass Tee Handle (1") 16. Indicator Flag Painted Steel 17. Body Gasket Elastomer 18. Lead Screw O-Ring Nitrile 19. Thrust Washer Anti-friction Polymer 20. Cover Gasket Neoprene 21. Flag Seal O-Ring Nitrile 22. Tamper-Proof Screw Stainless Steel 23. Pipe Plug (-4 units) Stainless Steel (Not shown) Refer to page 41 for details for TS-2M Switch Kit. 300 lb. WWP Bronze Ball Valves 300 PSI/20.7 Bar Non-Shock Cold Water CONFORMS TO MSS SP-110 • FM APPROVED • UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHAL LISTING NO. 7770-1243:103 APPROVED BY NEW YORK CITY M.E.A. 218-04-E WITH APPROPRIATE NYC INDICATOR. 1 2 3 4 5 6 7 8 9 10 20 16 11 22 21 14 15 17 18 19 12 13 DIMENSIONS—WEIGHTS—QUANTITIES Dimensions A B Weight Size Threaded Grooved Threaded Grooved C D E F G Cv† Threaded Grooved Box Master In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Value Lbs. Kg. Lbs. Kg. Qty. Ctn. Qty. 1 25 3.33 85 – – 1.66 42 – – 2.11 54 3.81 97 2.31 59 6.14 156 1.75 44 57 6.1 2.77 – – 1 10 1¹⁄₄ 32 4.18 106 – – 2.09 53 – – 2.46 62 4.21 107 2.72 69 6.33 161 3.50 89 103 7.1 3.23 – – 1 8 1¹⁄₂ 40 4.70 119 – – 2.35 60 – – 2.95 74 4.46 113 2.97 75 6.33 161 3.50 89 143 8.1 3.68 – – 1 4 2 50 5.15 131 6.71 170 2.57 65 3.36 85 3.69 94 4.67 119 3.18 81 6.33 161 3.50 89 245 10.7 4.86 9.7 4.40 1 4 2¹⁄₂ 65 5.65 144 7.28 185 2.92 74 3.64 93 3.75 95 4.67 119 3.18 81 6.33 161 3.50 89 183 13.0 5.91 12.6 5.73 1 4 † Note: Cv is defined as the flow in GPM that a valve will carry with a pressure drop of 1.0 psi when the media is water at 60° F. KT-505-W-8 Threaded KT-505W KG-505-W-8 Grooved Dezincification Resistant WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) · Website: http://www.zurn.com a company DOCUMENT #: REVISION: MIS-GAUGE 10/02 PRESSURE GAUGES SPECIFICATION SUBMITTAL SHEET FEATURES Model HGI-25 Hose Bibb Pressure Gauge with Maximum pressure indicator Application: Designed for measuring water system pressure within a build- ing. The 3/4® hose adapter allows for direct connection to a hose bibb or water heater drain valve. The indicator needle identifies the highest pressure reached within the system. Ideal for registering maximum system pressure caused by thermal expansion or pressure spikes. The maximum pres- sure indicator needle can be reset by turning the external knob counter clockwise. For water service only. ¯ Identify water service pressure to determine if a pressure regulator is needed. ¯ Troubleshoot pressure problems. ¯ Identify thermal expansion problems. Sizes: q 3/4® Hose Connection Dial size: 2® Range: 0-200 psi; minimum 2 psi graduation 3/4® hose adaptor Knurled for easy gripping Sold in convenient pegboard packaging FEATURES Model 92-25 & 92-25A Pressure Gauge Application: Designed for accurately measuring system pressure down- stream of a Pressure Reducing Valve. The Pressure gauge can be threaded directly to all WILKINS Pressure Reducing Valves supplied with tapped or plugged option. For water service only. Sizes: q 1/8® NPT (Model 92-25A) q 1/4® NPT (Model 92-25) Dial size: 2® range: 0-100 psi; minimum 2 psi graduation NOTE: A Pressure Regulator should be installed when sup- ply pressure exceeds 60psi. DIRECTION OF FLOW WATER METER SHUT-OFF VALVE MODEL BR4 REGULATOR HOSE BIBB HOSE BIBB PRESSURE GAUGE TYPICAL INSTALLATION (MODEL HGI-25) TYPICAL INSTALLATION (MODEL 92-25 & 92-25A) PRESSURE GAUGE DIRECTION OF FLOW WATER METER SHUT-OFF VALVE MODEL BR4 REGULATOR HOSE BIBB WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com a company DOCUMENT #: REVISION: BV-800C 5/05 Model 800C Swing Away Ball Valves For Liquid or Gas Installations SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on liquid or medical gas lines as a means of positive shut-off. The "swing away" design al- lows for repair and maintenance without removing the device from the line. DIMENSIONS & WEIGHTS (do not include pkg.) FEATURES Sizes: ‰ ½" ‰ ¾" ‰ 1" ‰ 1½" ‰ 2" ‰ 2 ½" ‰ 3" Maximum pressure 400 PSI WOG Copper connections (FC) ANSI B16.22 MATERIALS Main valve body Forged brass ( ½"-1") Cast bronze ASTM B 584 (1 ½"-3") Ball Brass ASTM B 16, chrome plated Seat & packing Teflon O-rings Buna Nitrile, NSF Listed A B C OPTIONS ‰ - with female copper inlet x outlet ‰ CL - with copper "L" tube extensions ACCESSORIES ‰ Repair kit; o-rings, stem and seats ‰ Bracket for locking ball valve handle in open position (Model BVLCK) ‰ Bracket and padlock (Model BVLCKP) SPECIFICATION The three piece swing away ball valve shall consist of a copper alloy body, two tailpieces, a hard-chromed copper alloy ball, two Teflon seats, a stem and coated handle. The stem shall be blow-out proof and the ball & seats replace- able in-line without the use of special tools. Tailpieces shall be designed to accept sweated copper tube or provided with copper tailpiece extensions. The three piece swing away ball valve shall be a WILKINS Model 800C. in. mm in. mm in. mm in. mm lbs. kg. 1 /2 15 2 1/8 54 1 5/8 41 3 7/8 98 1 0.5 3/4 20 2 3/4 70 1 7/8 48 3 7/8 98 1 0.5 1 25 3 1/2 89 2 51 4 1/2 114 2 1.0 1 1/2 40 4 7/8 124 2 7/8 73 6 152 7 3.0 2 50 5 1/2 140 3 1/8 79 6 152 9 4.0 2 1/2 65 6 3/8 162 3 5/8 92 6 152 17 8.0 3 80 6 3/4 172 4 3/8 111 12 305 22 10.0 SIZE WEIGHTS DIMENSIONS (approximate) A B C 1 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 ProPress® System Potable Water Hydronic Heating Chilled Water Compressed Air Nitrogen N2 Argon Low Pressure Steam Fire Protection Vacuum Corgon Oxygen 02 (non medical) System Data Sheet߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰2 ProPress Product Instructions ProPress for ½" to 2" copper tubing ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ 3 ProPress XL for 2¼" to 4" copper tubing ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ 4 ProPress ® Dimensional Documentation ProPress for ½" to 2" copper tubing ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ 5 ProPress XL for 2¼" to 4" copper tubing ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ 17 Viega Limited Warranty ProPress® Fittings And Valves ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰ ߰23 2 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 System Data Sheet ProPress® and ProPress XL (Copper) are safe, reliable and economical copper pipe installation systems that use modern cold press connection technology߰ Viega® ProPress fittings are for use with type K, L and M hard copper tubing from ½" to 4" and soft copper tubing in ½" to 1¼" diameters߰ All tubing must comply with the ASTM B88 standard߰ ProPress fittings are approved for installations in both above and below ground applications߰ Per code, local inspector approval must be obtained prior to installation below ground߰ ProPress has been used in Europe since the late 1980s and in the United States since the late 1990s for a variety of applications߰ Backed by two plumbing leaders with over 175 years of combined excellence߰ Listings and Certificates • NSF 61G • IAPMO PS117 • UL 213 • FM Class 1920 • ICC LC 1002 • CSA MSE-13 • ABS International Listings and Certificates • Deutsch Verein des Gas-und Wasserfachese߰V߰ (DVGW) • Lloyd’s Register (LR) • Det Norske Veritas (DNV) • Registro Italiano Navale (RINA) • Bureau Veritas (BV) • KIWA Compliant with: • ICC International Plumbing Code • IAPMO Uniform Plumbing Code • PHCC National Standard Plumbing Code • Florida Building Code, Volume II Plumbing Code • NFPA 13, 13D and 13R • ASME B16߰51 • U߰S߰ Coast Guard Viega ProPress fittings are offered in configurations including: Elbows, Couplings, Reducers, Tees, Reducing Tees, Threaded Adapters, Unions, Caps and Flanges߰ All threaded ½" to 2" fittings are Zero Lead bronze߰ Operating Parameters Operating Pressure: 200 PSI maximum Test Pressure: 600 PSI maximum Operating Temperature: 0°F to 250°F Approved Applications: • Potable Water • Hydronic Heating (w/ Glycol) • Chilled Water • Compressed Air • Non-medical Gases • Fire Sprinkler (175 PSI maximum) • Low Pressure Steam (15 PSI maximum) • Vacuum (29߰2 in߰ Hg maximum @ 68°F) In ProPress ½" to 4" dimensions, the Smart Connect Feature assures leakage of liquids and/or gases from inside the system past the sealing element of an unpressed connection߰ The function of this feature is to provide the installer quick and easy identification of connections which have not been pressed prior to putting the system into operation߰ Recommended Tools: • RIDGID RP 200-B (½" to 1¼") • RIDGID RP 210-B (½" to 1¼") • RIDGID RP 320-E • RIDGID RP 330-B or 330-C • RIDGID RP 340 • RIDGID CT 400 Contact your local Viega representative for details on local approvals߰ 3 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Viega ProPress® For Types K, L and M Hard Copper Tubing in ½" to 2" and Soft Copper Tubing in ½" to 1¼" Viega ProPress Insertion Depth Chart Tube Size ½" ¾" 1" 1¼" 1½" 2" Insertion Depth ¾" ⅞" ⅞" 1" 17/16" 19/16" 1߰ Cut copper tubing at right angles using displacement- type cutter or fine-toothed steel saw߰ 2߰ Remove burr from inside and outside of tubing to prevent cutting sealing element߰ 3߰ Check seal for correct fit߰ Do not use oils or lubricants߰ Use only Viega ProPress Shiny Black EPDM or Dull Black FKM sealing elements߰ Note: For applications requiring Viega ProPress with FKM sealing elements, remove the factory-installed EPDM sealing element and replace with FKM sealing element ߰ 4߰ Mark proper insertion depth as indicated by the Viega ProPress Insertion Depth Chart߰ Improper insertion depth may result in improper seal߰ 5߰ While turning slightly, slide press fitting onto tubing to the marked depth߰ Note: End of tubing must contact stop߰ 6߰ Insert appropriate Viega jaw into the pressing tool and push in, holding pin until it locks in place߰ 7߰ Open the jaw and place at right angles on the fitting߰ Visually check insertion depth using mark on tubing߰ 8߰ Start pressing process and hold the trigger until the jaw has engaged the fitting߰ 9߰ After pressing, the jaw can be opened again߰ Leak Testing with Smart Connect®: Unpressed connections are located by pressurizing the system with air or water߰ When testing with water the proper pressure range is 15 psi to 85 psi maximum߰ Leak testing with air can be dangerous at high pressures߰ When testing with compressed air the proper pressure range is ½ psi to 45 psi maximum߰ Following a successful leak test, the system may be pressure tested up to 200 psi with air, or up to 600 psi with water, if required by local code requirements or project specifications߰ 1 2 3 4 5 6 7 8 9 Read and understand all instructions for installing Viega ProPress fittings. Failure to follow all instructions may result in extensive property damage, serious injury or death. WARNING ProPress Product Instructions 4 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Viega ProPress® XL (Copper) For Types K, L and M Hard Copper Tubing in 2½" to 4" ProPress XL (copper) Insertion Depth Chart Tube Size 2½" 3" 4" Insertion Depth 111/16" 115/16" 2⅜" 1߰ Cut copper tubing at right angles using displacement- type cutter or fine-toothed steel saw߰ 2߰ Keep end of tubing a minimum of 4" away from the contact area of the vise to prevent possible damage to the tubing in the press area߰ 3߰ Remove burr from inside and outside of tubing to prevent cutting sealing element߰ 4߰ Check seal and grip ring for correct fit߰ Do not use oils or lubricants߰ Use only ProPress Shiny Black EPDM sealing elements߰ 5߰ Illustration demonstrates proper fit of grip ring, separation ring and sealing element߰ 6߰ Mark proper insertion depth as indicated by the ProPress XL (copper) Insertion Depth Chart߰ Improper insertion depth may result in an improper seal߰ 7߰ While turning slightly, slide press fitting onto tubing to the marked depth߰ End of tubing must contact stop߰ 8߰ ProPress XL (copper) fitting connections must be performed with ProPress XL-C Rings and V2 ACTUATOR߰ Use of ProPress XL Rings and/or Actuator (for Bronze fittings) will result in an improper connection߰ See Ridgid Operator’s Manual for proper tool instructions߰ 9߰ Open XL-C Ring and place at right angles on the fitting߰ XL-C Ring must be engaged on the fitting bead߰ Check insertion depth߰ 10߰ With V2 ACTUATOR inserted into the tool, open the V2 ACTUATOR as shown and connect V2 ACTUATOR to the XL-C Ring߰ 11߰ Place V2 ACTUATOR onto XL-C Ring and start pressing process߰ Hold the trigger until the Actuator has engaged the XL-C Ring߰ Keep extremities and foreign objects away from XL-C Ring and V2 ACTUATOR during pressing operation to prevent injury or incomplete press߰ 12߰ Release V2 ACTUATOR from XL-C Ring and then remove the XL-C Ring from the fitting on completion of press߰ Remove tag from fitting, indicating press has been performed߰ 1 2 3 5 6 7 8 9 10 11 12 4 Read, understand and follow all instructions for installing ProPress XL (copper) fittings. Failure to follow all instructions may result in extensive property damage, serious injury or death. Leak Testing with Smart Connect®: Unpressed connections are located by pressurizing the system with air or water߰ When testing with water the proper pressure range is 15 psi to 85 psi߰ Leak testing with air can be dangerous at high pressures߰ When testing with compressed air the proper pressure range is ½ psi to 45 psi߰ Following a successful leak test, the system may be pressure tested up to 200 psi with air, or up to 600 psi with water, if required by local code requirements or project specifications߰ 5 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 ProPress® Dimensional Documentation Part No. Size A (in) L (in) 1 1 77317 ½" x ½" 0߰75 1߰50 77322 ¾" x ¾" 1߰04 1߰94 77327 1" x 1" 1߰32 2߰23 77332 1¼" x 1¼" 1߰65 2߰68 77337 1½" x 1½" 1߰98 3߰40 77342 2" x 2" 2߰54 4߰13 Viega ProPress 90° Elbow Copper P x P - Model 2916 Part No. Size A (in) L (in) L1 (in) 1 2 77347 ½" x ½" 0߰75 1߰50 1߰54 77052 ¾" x ¾" 0߰76 1߰67 1߰83 77057 1" x 1" 1߰28 2߰19 2߰27 77062 1¼" x 1¼" 1߰28 2߰31 2߰48 77067 1½" x 1½" 1߰29 2߰72 2߰80 77072 2" x 2" 2߰16 3߰74 3߰78 Part No. Size A (in) L (in) L1 (in) 1 2 77347 ½" x ½" 0߰75 1߰50 1߰54 77352 ¾" x ¾" 1߰04 1߰94 1߰98 77357 1" x 1" 1߰32 2߰23 2߰27 77362 1¼" x 1¼" 1߰65 2߰68 2߰76 77367 1½" x 1½" 1߰98 3߰40 3߰48 77372 2" x 2" 2߰54 4߰13 4߰20 Viega ProPress 90° Street Elbow Copper P x FTG - Model 2916.1 Part No. Size A (in) L (in) 1 1 77317 ½" x ½" 0߰75 1߰50 77022 ¾" x ¾" 0߰76 1߰67 77027 1" x 1" 1߰28 2߰19 77032 1¼" x 1¼" 1߰28 2߰31 77037 1½" x 1½" 1߰29 2߰72 77042 2" x 2" 2߰16 3߰74 Viega ProPress 90° Elbow Copper P x P - Model 2916 Short 1 1 L A A L Viega ProPress 90° Street Elbow Copper P x FTG - Model 2916.1 Short 1 2 L A L1 ProPress for ½" to 2" copper tubing 6 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 A1 L1 Part No. Size A (in) A1 (in) L (in) L1 (in) 1 2 77325 ¾" x ½" 0߰91 0߰94 1߰81 1߰69 77330 1" x ¾" 1߰20 1߰30 2߰11 2߰21 Viega ProPress 90° Reducing Elbow Copper P x P - Model 2916.3 Part No. Size A (in) L (in) L1 (in) 1 2 77353 ¾" x ¾" 1߰02 1߰93 5߰98 Viega ProPress 90° Extended Street Elbow Copper P x FTG - Model 2947 A L1 Part No. Size A (in) L (in) 1 1 77607 ½" x ½" 0߰30 1߰04 77612 ¾" x ¾" 0߰43 1߰34 77617 1" x 1" 0߰55 1߰46 77622 1¼" x 1¼" 0߰68 1߰71 77627 1½" x 1½" 0߰81 2߰24 77632 2" x 2" 1߰05 2߰63 Viega ProPress 45° Elbow Copper P x P - Model 2926 Viega ProPress 45° Elbow Copper P x P - Model 2926 Short 1 1 L A AL Part No. Size A (in) L (in) 1 1 77607 ½" x ½" 0߰30 1߰04 77023 ¾" x ¾" 0߰36 1߰26 77028 1" x 1" 0߰47 1߰38 77033 1¼" x 1¼" 0߰58 1߰61 77038 1½" x 1½" 0߰65 2߰08 77043 2" x 2" 0߰86 2߰44 7 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size L (in) 1 1 78172 ½" x ½" 1߰61 78177 ¾" x ¾" 2߰01 78182 1" x 1" 1߰97 78187 1¼" x 1¼" 2߰20 78192 1½" x 1½" 2߰99 78197 2" x 2" 3߰31 Part No. Size A (in) L (in) 1 1 78047 ½" x ½" 0߰12 1߰61 78052 ¾" x ¾" 0߰20 2߰01 78057 1" x 1" 0߰16 1߰97 78062 1¼" x 1¼" 0߰14 2߰20 78067 1½" x 1½" 0߰14 2߰99 78072 2" x 2" 0߰14 3߰31 Viega ProPress Coupling with Stop Copper P x P - Model 2915 Viega ProPress Coupling No Stop Copper P x P - Model 2915.3 1 L 1 Viega ProPress 45° Street Elbow Copper P x FTG - Model 2926.1 Short 1 2 L A L1 Part No. Size A (in) L (in) L1 (in) 1 2 77637 ½" x ½" 0߰31 1߰06 1߰10 77053 ¾" x ¾" 0߰36 1߰26 1߰30 77058 1" x 1" 0߰47 1߰38 1߰49 77063 1¼" x 1¼" 0߰58 1߰61 1߰67 77068 1½" x 1½" 0߰65 2߰08 2߰04 77073 2" x 2" 0߰86 2߰44 2߰54 Part No. Size A (in) L (in) L1 (in) 1 2 77637 ½" x ½" 0߰31 1߰06 1߰10 77642 ¾" x ¾" 0߰43 1߰34 1߰37 77647 1" x 1" 0߰55 1߰46 1߰49 77652 1¼" x 1¼" 0߰68 1߰71 1߰79 77657 1½" x 1½" 0߰81 2߰24 2߰32 77662 2" x 2" 1߰05 2߰63 2߰71 Viega ProPress 45° Street Elbow Copper P x FTG - Model 2926.1 8 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size L (in) 1 1 79005 ½" x ½" 2߰99 79010 ¾" x ¾" 3߰50 79015 1" x 1" 3߰74 79020 1¼" x 1¼" 4߰13 79025 1½" x 1½" 4߰72 79030 2" x 2" 5߰31 Viega ProPress Extended Coupling Copper P x P - Model 2915.5 Part No. Size A (in) L (in) 1 2 78147 ¾" x ½" 0߰42 2߰07 15603 1" x ½" 0߰71 2߰36 78152 1" x ¾" 0߰48 2߰29 15593 1¼" x ¾" 0߰70 2߰64 78157 1¼" x 1" 0߰55 2߰48 18473 1½" x ¾" 0߰98 3߰33 15588 1½" x 1" 0߰74 3߰07 78162 1½" x 1¼" 0߰50 2߰96 18468 2" x ¾" 1߰54 4߰02 15608 2" x 1" 1߰29 3߰78 22328 2" x 1¼" 0߰81 3߰43 78167 2" x 1½" 0߰74 3߰75 Viega ProPress Reducer Copper P x P - Model 2915.2 1 1 L Part No. Size A (in) L (in) 1 2 78077 ¾" x ½" 1߰42 2߰17 78082 1" x ½" 1߰69 2߰44 78087 1" x ¾" 1߰42 2߰32 22333 1¼" x ½" 1߰91 2߰74 78092 1¼" x ¾" 1߰85 2߰76 78097 1¼" x 1" 1߰57 2߰48 14543 1½" x ¾" 2߰56 3߰46 78102 1½" x 1" 2߰28 3߰19 78107 1½" x 1¼" 2߰04 3߰07 78112 2" x 1" 3߰03 3߰94 78117 2" x 1¼" 2߰79 3߰82 78122 2" x 1½" 2߰63 4߰06 Viega ProPress Reducer Copper FTG x P - Model 2915.1 9 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size A (in) A1 (in) A2 (in) L (in) L1 (in) L2 (in) 1 2 3 77377 ½" x ½" x ½" 0߰75 0߰75 0߰50 1߰50 1߰50 1߰25 77382 ½" x ½" x ¾" 0߰91 0߰91 0߰59 1߰65 1߰65 1߰50 15493 ½" x ½" x 1" 1߰10 1߰10 0߰55 1߰85 1߰85 1߰46 77387 ¾" x ¾" x ¾" 0߰85 0߰85 0߰59 1߰75 1߰75 1߰50 77392 ¾" x ½" x ½" 0߰69 0߰98 0߰63 1߰59 1߰73 1߰38 77397 ¾" x ½" x ¾" 0߰85 1߰14 0߰59 1߰75 1߰89 1߰50 77402 ¾" x ¾" x ½" 0߰69 0߰69 0߰63 1߰59 1߰59 1߰38 77407 ¾" x ¾" x 1" 0߰97 0߰97 0߰63 1߰87 1߰87 1߰54 77412 1" x 1" x 1" 0߰97 0߰97 0߰79 1߰87 1߰87 1߰69 22263 1" x ½" x ¾" 0߰85 1߰24 0߰75 1߰76 1߰99 1߰66 94767 1" x ½" x 1" 0߰97 1߰52 0߰79 1߰87 2߰26 1߰69 77417 1" x ¾" x ½" 0߰69 0߰89 0߰79 1߰59 1߰79 1߰54 77422 1" x ¾" x ¾" 0߰85 1߰04 0߰75 1߰75 1߰95 1߰65 77427 1" x ¾" x 1" 0߰97 1߰18 0߰78 1߰87 2߰07 1߰69 77432 1" x 1" x ½" 0߰69 0߰69 0߰79 1߰59 1߰59 1߰54 77437 1" x 1" x ¾" 0߰85 0߰85 0߰75 1߰75 1߰75 1߰65 15488 1" x 1" x 1 ¼" 1߰16 1߰16 0߰84 2߰07 2߰07 1߰87 77442 1¼" x 1¼ x 1¼" 1߰02 1߰02 0߰86 2߰05 2߰05 1߰89 22253 1¼" x ½" x 1¼" 1߰02 1߰77 0߰87 2߰05 2߰52 1߰89 22243 1¼" x ¾" x ½" 0߰64 1߰13 0߰93 1߰68 2߰03 1߰68 22258 1¼" x ¾" x ¾" 0߰76 1߰30 0߰87 1߰80 2߰21 1߰78 22268 1¼" x ¾" x 1" 0߰88 1߰40 0߰91 1߰91 2߰31 1߰82 22248 1¼" x ¾" x 1¼" 1߰02 1߰54 0߰86 2߰05 2߰45 1߰89 22238 1¼" x 1" x ½" 0߰64 0߰91 0߰93 1߰68 1߰82 1߰68 94762 1¼" x 1" x ¾" 0߰76 1߰14 0߰87 1߰79 2߰05 1߰77 14568 1¼" x 1" x 1" 0߰88 1߰28 0߰91 1߰91 2߰19 1߰81 94757 1¼" x 1¼" x ½" 0߰65 0߰65 0߰93 1߰67 1߰67 1߰67 77452 1¼" x 1¼" x ¾" 0߰77 0߰77 0߰89 1߰79 1߰79 1߰77 77447 1¼" x 1¼" x 1" 0߰88 0߰88 0߰90 1߰91 1߰91 1߰81 77457 1½" x 1½" x 1½" 1߰13 1߰13 1߰13 2߰56 2߰56 2߰56 79660 1½" x 1" x ¾" 0߰67 1߰39 1߰16 2߰17 2߰44 2߰05 15458 1½" x 1" x 1" 0߰74 1߰54 1߰06 2߰17 2߰44 1߰97 15463 1½" x 1" x 1½" 1߰13 1߰83 1߰13 2߰56 2߰74 2߰56 22233 1½" x 1¼" x ¾" 0߰67 1߰08 1߰15 2߰09 2߰11 2߰05 15453 1½" x 1¼" x 1" 0߰74 1߰29 1߰18 2߰17 2߰32 2߰09 15483 1½" x 1¼" x 1¼" 0߰86 1߰33 1߰13 2߰28 2߰36 2߰17 15448 1½" x 1½" x ½" 0߰47 0߰47 1߰10 1߰89 1߰89 1߰85 77462 1½" x 1½" x ¾" 0߰66 0߰66 1߰14 2߰09 2߰09 2߰05 77467 1½" x 1½" x 1" 0߰74 0߰74 1߰18 2߰17 2߰17 2߰09 77472 1½" x 1½" x 1¼" 0߰86 0߰86 1߰13 2߰28 2߰28 2߰17 77477 2" x 2" x 2" 1߰37 1߰37 1߰37 2߰95 2߰95 2߰95 15518 2" x 1¼" x 1¼" 0߰94 1߰84 1߰33 2߰52 2߰87 2߰36 15513 2" x 1½" x ¾" 0.70 1.25 1.38 2.28 2.68 2߰28 15498 2" x 1½" x 1" 0.82 1.45 1.38 2.40 2.87 2߰28 15508 2" x 1½" x 1¼" 0.94 1.55 1.49 2.52 2.97 2߰52 Continued on next page Viega ProPress Tee Copper P x P x P - Model 2918 10 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size L (in) D (in) 1 77712 ½" 0߰92 0߰79 77717 ¾" 1߰07 0߰94 77722 1" 1߰11 0߰99 77727 1¼" 1߰32 1߰20 77732 1½" 1߰62 1߰49 77737 2" 1߰81 1߰69 Viega ProPress Cap Copper P - Model 2956 Part No. Size A (in) L (in) H (in) 1 1 77742 ½" x ½" 3߰62 5߰12 0߰77 77747 ¾" x ¾" 4߰49 6߰30 0߰90 Viega ProPress Cross-Over Copper P x P - Model 2928 1 D L Part No. Size A (in) L (in) H (in) 1 2 78137 ½" x ½" 3߰83 4߰58 1߰10 78142 ¾" x ¾" 4߰64 5߰54 1߰54 Viega ProPress Cross-Over Copper P x FTG - Model 2927 Copper Tee P x P x P - Model 2918 (continued) Part No. Size A (in) A1 (in) A2 (in) L (in) L1 (in) L2 (in) 1 2 3 15503 2" x 1½" x 1½" 1.13 1.65 1.37 2.72 3.07 2߰80 22228 2" x 1½" x 2" 1.38 1.89 1.38 2.95 3.33 2߰95 15538 2" x 2" x ½" 0.54 0.54 1.30 2.13 2.13 2߰05 94777 2" x 2" x ¾" 0.79 0.79 1.26 2.37 2.37 2߰17 94772 2" x 2" x 1" 0.91 0.91 1.30 2.49 2.49 2߰21 77487 2" x 2" x 1¼" 1.04 1.04 1.37 2.62 2.62 2߰40 77482 2" x 2" x 1½" 1.13 1.13 1.37 2.72 2.72 2߰80 11 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size A (in) L (in) 1 2 79210 ½" x ⅜" MPT 0߰77 1߰59 79215 ½" x ½" MPT 0߰89 1߰71 79220 ½" x ¾" MPT 1߰00 1߰83 79225 ¾" x ½" MPT 1߰02 1߰93 79230 ¾" x ¾" MPT 1߰02 1߰93 79235 ¾" x 1" MPT 1߰18 2߰09 79240 1" x ¾" MPT 1߰18 2߰09 79245 1" x 1" MPT 1߰26 2߰17 79250 1" x 1¼" MPT 1߰54 2߰44 79255 1¼" x 1" MPT 1߰22 2߰24 79260 1¼" x 1¼" MPT 1߰34 2߰36 79265 1¼" x 1½" MPT 1߰48 2߰50 79270 1½" x 1¼" MPT 1߰34 2߰76 79275 1½" x 1½" MPT 1߰28 2߰70 79280 1½" x 2" MPT 1߰65 3߰07 79285 2" x 1½" MPT 1߰54 3߰11 79290 2" x 2" MPT 1߰50 3߰07 Viega ProPress Adapter Zero Lead Bronze P x MPT - Model 2911ZL 1 2 L A Part No. Size A (in) L (in) 1 2 79295 ½" x ⅜" FPT 0߰19 1߰42 79300 ½" x ½" FPT 0߰25 1߰61 79305 ½" x ¾" FPT 0߰27 1߰65 79310 ¾" x ½" FPT 0߰33 1߰77 79315 ¾" x ¾" FPT 0߰35 1߰81 79320 1" x ½" FPT 0߰41 1߰85 79325 1" x ¾" FPT 0߰39 1߰85 79330 1" x 1" FPT 0߰44 2߰01 79335 1" x 1¼" FPT 0߰50 2߰09 79340 1¼" x ½" FPT 0߰37 1߰93 79345 1¼" x 1" FPT 0߰24 1߰93 79350 1¼" x 1¼" FPT 0߰34 2߰05 79355 1¼" x 1½" FPT 0߰42 2߰13 79360 1½" x 1¼" FPT 0߰26 2߰36 79365 1½" x 1½" FPT 0߰34 2߰44 79370 2" x 2" FPT 0߰41 2߰68 Viega ProPress Adapter Zero Lead Bronze P x FPT - Model 2912ZL 21 L A 12 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size L (in) 1 2 79375 ½" x ⅜" MPT 1߰75 79380 ½" x ½" MPT 1߰95 79385 ½" x ¾" MPT 2߰05 79390 ¾" x ½" MPT 1߰93 79395 ¾" x ¾" MPT 2߰05 79400 1" x ¾" MPT 2߰05 79405 1" x 1" MPT 2߰22 79410 1¼" x 1¼" MPT 2߰54 79415 1½" x 1½" MPT 2߰89 79420 2" x 2" MPT 3߰33 Viega ProPress Adapter Zero Lead Bronze FTG x MPT - Model 2911.1ZL Part No. Size A (in) L (in) 1 2 79425 ½" x ⅜" FPT 1߰10 1߰54 79430 ½" x ½" FPT 1߰22 1߰75 79435 ½" x ¾" FPT 1߰30 1߰83 79440 ¾" x ½" FPT 1߰26 1߰79 79445 ¾" x ¾" FPT 1߰28 1߰83 79455 1" x ½" FPT 1߰35 1߰99 79450 1" x 1" FPT 1߰33 1߰99 79460 1¼" x ½" FPT 1߰65 2߰19 79465 1¼" x 1¼" FPT 1߰50 2߰19 79470 1½" x 1½" FPT 1߰88 2߰56 79475 2" x 2" FPT 2߰13 2߰95 Viega ProPress Adapter Zero Lead Bronze FTG x FPT - Model 2912.1ZL L 21 21 L A Part No. Size A (in) A1 (in) L (in) L1 (in) 1 2 79520 ½" x ⅜" FPT 0߰94 0߰42 1߰77 0߰83 79525 ½" x ½" FPT 0߰94 0߰57 1߰77 1߰10 79530 ½" x ¾" FPT 1߰06 0߰51 1߰89 1߰06 79535 ¾" x ½" FPT 1߰06 0߰65 1߰97 1߰18 79540 ¾" x ¾" FPT 1߰06 0߰57 1߰97 1߰12 79545 1" x ½" FPT 1߰06 0߰72 1߰97 1߰26 79550 1" x 1" FPT 1߰34 0߰76 2߰24 1߰42 79560 1¼" x 1¼" FPT 1߰54 0߰89 2߰56 1߰57 79565 1½" x 1½" FPT 1߰69 1߰05 3߰11 1߰73 79570 2" x 2" FPT 2߰17 1߰35 3߰74 2߰05 Viega ProPress 90° Elbow Zero Lead Bronze P x FPT - Model 2914.2ZL 1 2 L1 A1 L A 13 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size A (in) A1 (in) L (in) L1 (in) L2 (in) 1 2 79205 ½" x ½" FPT 0߰94 0߰57 1߰77 1߰10 1߰07 Viega ProPress 90° Hi Ear Elbow Zero Lead Bronze P x FPT - Model 2925.2ZL Part No. Size A (in) L (in) L1 (in) L2 (in) L3 (in) 1 2 79185 ½" x ⅜" FPT 0߰94 1߰77 0߰74 0߰83 0߰67 79190 ½" x ½" FPT 0߰94 1߰77 0߰74 1߰10 0߰67 79195 ¾" x ¾" FPT 1߰06 1߰97 0߰83 1߰12 0߰83 Viega ProPress 90° Drop Ear Elbow Zero Lead Bronze P X FPT - Model 2925.5ZL 1 L1 A1 L2 2 L A 1 2 L3 L2 A L1 L Viega ProPress Double Drop Elbow Zero Lead Bronze P x P x FPT - Model 2928.7ZL 1 2 L1 L4 L A 3 L2 L3 Part No. Size A (in) L (in) L1 (in) L2 (in) L3 (in) L4 (in) 1 2 3 78800 ½" x ½" x ½" FNPT 1߰34 2߰17 1߰97 1߰10 0߰67 1߰57 78802 ¾" x ¾" x ½" FNPT 1߰54 2߰44 1߰97 1߰10 0߰83 2߰05 78801 ¾" x ¾" x ¾" FNPT 1߰54 2߰44 1߰97 1߰12 0߰83 1߰89 78803 1" x 1" x ½" FNPT 1߰77 2߰68 2߰36 1߰10 0߰87 2߰52 Part No. Size A (in) L (in) 1 2 79850 1½" x ½" 1߰95 2߰78 79855 2" x ½" 2߰38 3߰21 79860 2" x ¾" 2߰42 3߰33 Viega ProPress Reducer Zero Lead Bronze FTG x P - Model 2915.1ZL 14 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size A (in) A1 (in) L (in) L1 (in) 1 2 3 79580 ½" x ½" x ½" FPT 0߰79 0߰69 1߰61 1߰30 79585 ¾" x ¾" x ¼" FPT 0߰67 0߰79 1߰57 1߰18 79590 ¾" x ¾" x ½" FPT 0߰79 0߰88 1߰69 1߰42 79595 ¾" x ¾" x ¾" FPT 0߰91 0߰59 1߰81 1߰14 79760 1" x 1" x ½" FPT 0߰79 1߰04 1߰69 1߰57 79765 1" x 1" x ¾" FPT 0߰91 1߰06 1߰81 1߰61 79770 1¼" x 1¼" x ½" FPT 0߰83 1߰16 1߰85 1߰69 79775 1¼" x 1¼" x ¾" FPT 0߰95 1߰18 1߰97 1߰73 79780 1½" x 1½" x ½" FPT 0߰87 1߰24 2߰28 1߰77 79785 1½" x 1½" x ¾" FPT 0߰94 1߰30 2߰36 1߰85 79790 2" x 2" x ½" FPT 0߰98 1߰59 2߰56 2߰13 79795 2" x 2" x ¾" FPT 1߰06 1߰65 2߰64 2߰20 Viega ProPress Tee Zero Lead Bronze P x P x FPT - Model 2917.2ZL 2 3 1 L1 A1 L L A A Part No. Size A (in) A1 (in) A2 (in) L (in) L1 (in) L2 (in) 1 2 3 79635 ½" x ⅛" FPT x ½" 0߰67 0߰67 0߰44 1߰50 1߰50 0߰71 79640 ¾" x ⅛" FPT x ¾" 0߰83 0߰83 0߰54 1߰73 1߰73 0߰81 Viega ProPress Vent Tee Zero Lead Bronze P x FPT x P - Model 2917.3ZL 3 1 2 L1 A1 A2 L L2 A Part No. Size A (in) L (in) 1 79125 ½" 1߰19 2߰84 79130 ¾" 1߰34 3߰15 79135 1" 1߰83 3߰65 79140 1¼" 1߰64 3߰69 79145 1½" 2߰13 4߰96 79150 2" 2߰07 5߰22 Viega ProPress Union Zero Lead Bronze P x P - Model 2960ZL 15 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size A (in) L (in) 1 2 79700 ½" x ½" FPT 0߰91 2߰27 79705 ¾" x ¾" FPT 0߰96 2߰42 79710 1" x 1" FPT 1߰31 2߰88 79715 1¼" x 1¼" FPT 1߰27 2߰97 79720 1½" x 1½" FPT 1߰77 3߰87 79725 2" x 2" FPT 1߰65 3߰92 Viega ProPress Union Zero Lead Bronze P x FPT - Model 2962ZL 1 2 A L Part No. Size A (in) L (in) 1 2 79730 ½" x ½" MPT 1߰86 2߰69 79735 ¾" x ¾" MPT 2߰00 2߰90 79740 1" x 1" MPT 2߰54 3߰45 79745 1¼" x 1¼" MPT 2߰49 3߰52 79750 1½" x 1½" MPT 3߰05 4߰47 79755 2" x 2" MPT 2߰99 4߰57 Viega ProPress Union Zero Lead Bronze P x MPT - Model 2965ZL Part No. Size A (in) L (in) 1 2 79155 ½" x ½" FPT 0߰88 2߰24 79160 ¾" x ¾" FPT 1߰11 2߰57 79165 1" x 1" FPT 1߰00 2߰57 79170 1¼" x 1¼" FPT 0߰97 2߰68 79175 1½" x 1½" FPT 1߰01 3߰11 79180 2" x 2" FPT 1߰26 3߰53 Viega ProPress Dielectric Union Zero Lead Bronze P x FPT - Model 2967ZL 1 2 L A Part No. Size A (in) L (in) 1 2 79800 ½" x 1" BSP 0߰39 1߰57 79805 ¾" x 1" BSP 0߰63 1߰87 79810 1" x 1" BSP 0߰91 2߰14 79815 1" x 1¼" BSP 0߰73 2߰04 Viega ProPress Tailpiece Zero Lead Bronze P x F BSP - Model 2957ZL A 21 L 16 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part No. Size L (in) A (in) b (in) D (in) k (in) d (in) 1 79680 1" 2߰76 1߰85 0߰84 4߰33 3߰11 0߰63 79685 1¼" 2߰76 1߰73 0߰84 4߰53 3߰50 0߰63 79690 1½" 3߰07 1߰65 0߰84 4߰92 3߰86 0߰63 79695 2" 3߰66 2߰09 0߰84 5߰91 4߰76 0߰75 Viega ProPress Adapter Flange Zero Lead Bronze P x Flange - Model 2959.5ZLA b L k D 1 d Part No. Size A (in) L (in) 1 2 99620 ½"x ½" 0߰29 1߰61 99626 ½" x ¾" 0߰43 1߰83 99630 ¾" x ½" 0߰23 1߰56 99640 ¾"x ¾" 0߰33 1߰73 99660 1" x 1" 0߰45 1߰97 99670 1¼" x 1¼" 0߰49 2߰38 99680 1½" x 1½" 0߰59 2߰87 99690 2" x 2" 0߰58 3߰21 Viega PEX Press Adapter Zero Lead Bronze P x P - Model 2813PZL A 1 2 L L A Flow 21 A2 Part No. Size A (in) A2 (in) L (in) 1 2 78810 1¼" x 1¼" 1߰02 1߰60 3߰07 78811 1½" x 1½" 1߰43 2߰10 3߰98 78812 2" x 2" 1߰58 2߰45 4߰48 Viega ProPress Venturi Insert Zero Lead Bronze - Model 2911.5ZL 17 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part Number Size A (in) L (in) 1 1 20623 2½" x 2½" 3߰19 4߰88 20628 3" x 3" 3߰76 5߰73 20633 4" x 4" 4߰90 7߰26 Viega ProPress XL-C 90° Elbow P x P - Model 0916XL Part Number Size A (in) L (in) L1 (in) 1 2 20638 2½" x 2½" 3߰19 4߰88 4߰80 20643 3" x 3" 3߰76 5߰73 5߰63 20648 4" x 4" 4߰90 7߰26 7߰13 Viega ProPress XL-C 90° Street Elbow P x FTG - Model 0916.1XL Part Number Size A (in) L (in) L1 (in) 1 2 20668 2½" x 2½" 1߰48 3߰18 3߰10 20673 3" x 3" 1߰73 3߰70 3߰60 20678 4" x 4" 2߰23 4߰59 4߰45 Viega ProPress XL-C 45° Street Elbow P x FTG - Model 0926.1XL Part Number Size A (in) L (in) 1 1 20653 2½" x 2½" 1߰48 3߰18 20658 3" x 3" 1߰73 3߰70 20663 4" x 4" 1߰96 4߰63 Viega ProPress XL-C 45° P x P - Model 0926XL ProPress XL for 2¼" to 4" copper tubing 18 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part Number Size A (in) L (in) 1 2 20685 2½" x 1" 1߰76 4߰36 20690 2½" x 1¼" 1߰61 4߰34 20695 2½" x 1½" 1߰52 4߰64 20700 2½" x 2" 1߰41 4߰69 20705 3" x 1½" 1߰78 5߰17 20710 3" x 2" 1߰53 5߰08 20715 3" x 2½" 1߰41 5߰07 20720 4" x 2" 2߰06 6߰00 20725 4" x 2½" 1߰93 5߰99 20730 4" x 3" 1߰70 6߰03 Viega ProPress XL-C Reducer P x P - Model 0915.2XL Part Number Size A (in) L (in) 1 1 20728 2½" x 2½" 0߰95 4߰33 20733 3" x 3" 0߰98 4߰92 20738 4" x 4" 1߰06 5߰79 Viega ProPress XL-C Coupling with Stop P x P - Model 0915XL Part Number Size A (in) L (in) 1 2 20814 2½" x 1" 3߰61 4߰52 20815 2½" x 1¼" 3߰47 4߰51 20813 2½" x 1½" 3߰41 4߰84 20758 2½" x 2" 2߰35 3߰94 20817 3" x 1¼" 3߰96 5߰00 20818 3" x 1½" 3߰91 5߰34 20763 3" x 2" 2߰98 4߰57 20768 3" x 2½" 2߰76 4߰45 20773 4" x 2" 4߰58 6߰17 20778 4" x 2½" 4߰45 6߰15 20783 4" x 3" 4߰17 6߰14 Viega ProPress XL-C Reducer FTG x P - Model 0915.1XL Part Number Size L (in) 1 1 20743 2½" x 2½" 4߰33 20748 3" x 3" 4߰92 20753 4" x 4" 5߰79 Viega ProPress XL-C Coupling No Stop P x P - Model 0915.5XL 19 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part Number Size A (in) L (in) 1 2 20823 2½"x 2½" MPT 2߰76 4߰45 20828 3"x 3" MPT 2߰84 4߰80 20838 4"x 4" MPT 3߰10 5߰46 Viega ProPress XL-C Adapter P x MPT - Model 0911XL Part Number Size A (in) L (in) 1 2 20819 2½" x 2½" FPT 1߰53 4߰15 20829 3" x 3" FPT 1߰84 4߰82 20839 4" x 4" FPT 2߰09 5߰55 Viega ProPress XL-C Adapter P x FPT - Model 0912XL Part Number Size A (in) A1 (in) A2 (in) L (in) L1 (in) L2 (in) 1 2 3 20684 2½" x ¾" x 2½" 1߰83 1߰91 3߰23 3߰52 3߰60 4߰13 20689 2½" x 1" x 2½" 1߰83 1߰91 3߰25 3߰52 3߰60 4߰15 20694 2½" x 1¼" x 2½" 1߰83 1߰91 3߰20 3߰52 3߰60 4߰23 20699 2½" x 1½" x 2½" 1߰83 1߰91 3߰14 3߰52 3߰60 4߰57 20704 2½" x 2" x ¾" 1߰04 1߰61 1߰59 2߰74 2߰52 3߰17 20709 2½" x 2" x 1" 1߰04 1߰77 1߰65 2߰74 2߰67 3߰24 22283 2½" x 2" x 1½" 1߰30 1߰78 2߰07 2߰99 3߰20 3߰66 22278 2½" x 2" x 2" 1߰50 1߰78 2߰25 3߰19 3߰36 3߰83 20714 2½" x 2" x 2½" 1߰83 1߰91 2߰41 3߰52 3߰60 4߰00 22303 2½" x 2½" x ½" 0߰91 1߰52 0߰91 2߰60 2߰27 2߰60 22298 2½" x 2½" x ¾" 0߰91 1߰58 0߰91 2߰60 2߰48 2߰60 22293 2½" x 2½" x 1" 1߰04 1߰77 1߰04 2߰74 2߰68 2߰74 22288 2½" x 2½" x 1¼" 1߰16 1߰76 1߰16 2߰85 2߰79 2߰85 20803 2½" x 2½" x 1½" 1߰30 1߰78 1߰30 2߰99 3߰21 2߰99 20688 2½" x 2½" x 2" 1߰54 1߰75 1߰54 3߰23 3߰34 3߰23 20683 2½" x 2½" x 2½" 1߰83 1߰94 1߰83 3߰52 3߰63 3߰52 20719 3" x ¾" x 3" 2߰07 2߰15 3߰82 4߰04 4߰11 4߰72 20724 3" x 1" x 3" 2߰07 2߰15 3߰96 4߰04 4߰11 4߰86 20729 3" x 1¼" x 3" 2߰07 2߰15 3߰83 4߰04 4߰11 4߰86 Continued on next page Viega ProPress XL-C Tee P x P x P - Model 0918XL 20 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part Number Size A (in) A1 (in) A2 (in) L (in) L1 (in) L2 (in) 1 2 3 20727 3" x 1½" x 3" 2߰07 2߰15 3߰71 4߰04 4߰11 5߰14 20732 3" x 2" x 2" 1߰56 2߰03 2߰33 3߰52 3߰61 3߰92 20734 3" x 2" x 2½" 1߰85 2߰15 2߰63 3߰82 3߰85 4߰21 20739 3" x 2" x 3" 2߰07 2߰15 2߰84 4߰04 4߰11 4߰43 20744 3" x 2½" x 2" 1߰56 2߰03 2߰07 3߰52 3߰61 3߰76 20749 3" x 2½" x 2½" 1߰85 2߰15 2߰56 3߰82 3߰85 4߰25 20754 3" x 2½" x 3" 2߰07 2߰15 2߰78 4߰04 4߰11 4߰47 20759 3" x 3" x ½" 0߰93 1߰76 0߰93 2߰89 2߰50 2߰89 22323 3" x 3" x ¾" 0߰93 1߰80 0߰93 2߰89 2߰71 2߰89 22308 3" x 3" x 1" 1߰06 2߰02 1߰06 3߰03 2߰92 3߰03 22313 3" x 3" x 1¼" 1߰18 2߰01 1߰18 3߰15 3߰04 3߰15 20798 3" x 3" x 1½" 1߰32 2߰03 1߰32 3߰29 3߰45 3߰29 20698 3" x 3" x 2" 1߰56 2߰00 1߰56 3߰52 3߰59 3߰52 20703 3" x 3" x 2½" 1߰85 2߰15 1߰85 3߰82 3߰85 3߰82 20693 3" x 3" x 3" 2߰07 2߰21 2߰07 4߰04 4߰18 4߰04 20774 4" x 3" x 2" 1߰59 2߰57 3߰33 3߰96 4߰15 5߰22 20784 4" x 3" x 3" 2߰11 2߰66 3߰84 4߰47 4߰63 5߰81 20788 4" x 4" x ½" 1߰08 2߰24 1߰08 3߰45 2߰99 3߰45 20793 4" x 4" x ¾" 1߰08 2߰32 1߰08 3߰45 3߰22 3߰45 20794 4" x 4" x 1" 1߰36 2߰52 1߰36 3߰72 3߰42 3߰72 20795 4" x 4" x 1¼" 1߰36 2߰50 1߰36 3߰72 3߰54 3߰72 20808 4" x 4" x 1½" 1߰36 2߰52 1߰36 3߰72 3߰95 3߰72 20713 4" x 4" x 2" 1߰59 2߰53 1߰59 3߰96 4߰11 3߰96 20718 4" x 4" x 2½" 1߰89 2߰65 1߰89 4߰25 4߰35 4߰25 20723 4" x 4" x 3" 2߰11 2߰69 2߰11 4߰47 4߰65 4߰47 20708 4" x 4" x 4" 2߰60 2߰72 2߰60 4߰96 5߰09 4߰96 Viega ProPress XL-C Tee P x P x FPT - Model 0917.2XL Part Number Size A (in) A1 (in) L (in) L1 (in) 1 2 3 20883 2½" x 2½" x ¾" FPT 1߰02 1߰78 2߰72 2߰34 20878 2½" x 2½" x 2" FPT 1߰54 1߰90 3߰23 2߰60 20893 3" x 3" x ¾" FPT 1߰04 2߰03 3߰01 2߰59 20888 3" x 3" x 2" FPT 1߰56 2߰16 3߰52 2߰85 20873 4" x 4" x ¾" FPT 1߰08 2߰53 3߰34 3߰09 20868 4" x 4" x 2" FPT 1߰59 2߰69 3߰96 3߰38 Viega ProPress XL-C Tee P x P x P - Model 0918XL (continued from previous page) 21 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Part Number Size A (in) L (in) b (in) k (in) D (in) d (in) 1 20853 2½" 1߰09 2߰79 0߰70 5߰51 7߰09 0߰75 20858 3" 1߰20 3߰17 0߰79 5߰98 7߰48 0߰75 Viega ProPress XL-C Adapter Flange P x Flange - Model 0959.5XL Part Number Size A (in) L (in) b (in) k (in) D (in) d (in) 1 20863 4" 1߰29 3߰66 0߰86 7߰52 9߰06 0߰75 Viega ProPress XL-C Adapter Flange P x Flange - Model 0959.5XL Part Number Size A (in) L (in) 1 20833 2½" 0߰39 2߰11 20843 3" 0߰39 2߰36 20848 4" 0߰39 2߰76 Viega ProPress XL-C Cap P - Model 0956XL 22 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 Butterfly Valve - Model 2873.81 Part No. Size A (in) B (in) C (in) D (in) E (in) F (in) G (in) H (in) I (in) 22076 4" 9߰06 8߰47 3߰54 0߰91 2߰05 3߰62 6߰42 8߰27 7߰48 Butterfly Valve - Model 2873.81 Part No. Size A (in) B (in) C (in) D (in) E (in) F (in) G (in) H (in) I (in) 22074 2½" 6߰50 7߰40 2߰17 0߰43 1߰81 2߰64 5߰35 5߰20 5߰51 22075 3" 7߰28 7߰64 2߰80 0߰67 1߰81 2߰82 5߰59 7߰01 5߰98 A C B E D G F A C B E D G F I H I H 23 of 23 Submittal Package SM-PP 1116 Viega LLC, 100 N. Broadway, 6th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 *Zero Lead identifies Viega® products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372 (0߰25% or less maximum weighted average lead content)߰ Viega Limited Warranty ProPress® Fittings And Valves Subject to the conditions and limitations in this Limited Warranty, Viega LLC (VIEGA) warrants to wholesalers and licensed plumbing and mechanical contractors in the United States and Canada that its PROPRESS fittings, when properly installed in non industrial and non marine applications and under normal conditions of use, will be free of failure from manufacturing defect for a period of fifty (50) years from date of installation and that its PROPRESS valves, when properly installed in non industrial and non marine applications and under normal conditions of use, will be free of failure from manufacturing defect for a period of two (2) years from date of installation߰ Under this Limited Warranty, you only have a right to a remedy if the failure or leak resulted from a manufacturing defect in the products covered by this warranty and the failure or leak occurred during the warranty period߰ You do not have a remedy under this warranty and the warranty does not apply if the failure or any resulting damage is caused by (1) components other than those manufactured or sold by Viega; (2) not designing, installing, inspecting, or testing the ProPress fittings or valves in accordance with Viega’s installation instructions in effect at the time of the installation; applicable code requirements; and accepted industry practice; (3) improper handling and protection of the product prior to and during installation, inadequate freeze protection, exposure to water pressures or temperatures or in applications outside acceptable operating conditions; (4) acts of nature such as, but not limited to, earthquakes, fire, flood, or lightning, or (5) external environmental causes, such as water quality variations, aggressive water, or other external chemical or physical conditions߰ In the event of a leak or other failure of the parts covered by this warranty, it is the responsibility of the property owner to obtain and pay for repairs߰ Only if the warranty applies will Viega be responsible for the remedy under this warranty߰ The part or parts which you claim failed should be kept and Viega contacted by writing to the address below or telephoning 1-800-976-9819 within thirty (30) days after the leak or other failure and identifying yourself as having a warranty claim߰ You should be prepared to ship, at your expense, the product which you claim failed due to a manufacturing defect and document the date of installation߰ Within a reasonable time after receiving the product, Viega will investigate the reasons for the failure, which includes the right to inspect the product at Viega߰ Viega will notify you in writing of the results of its review߰ In the event that Viega determines that the failure or leak was the result of a manufacturing defect in the part covered by this warranty and that this warranty applies, the EXCLUSIVE AND ONLY REMEDY under this warranty shall be the reimbursement for repair and/or replacement of the part߰ VIEGA SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR OTHER DAMAGE (FOR EXAMPLE, WATER OR PROPERTY OR MOLD REMEDIATION) UNDER ANY LEGAL THEORY AND WHETHER ASSERTED BY DIRECT ACTION, FOR CONTRIBUTION OR INDEMNITY OR OTHERWISE߰ THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE߰ If a limited warranty shall be found to apply, such warranty is limited to four years߰ Other than this Limited Warranty, Viega does not authorize any person or firm to create for it any other obligation or liability in connection with its products߰ This Limited Warranty gives you specific legal rights and you also may have other rights which may vary from state to state߰ This warranty shall be interpreted and applied under the law of the state in which the product is installed and is intended as a Commercial Warranty߰ This document subject to updates߰ For the most current Viega technical literature please visit www߰viega߰us߰ Click Services -> Click Electronic Literature Downloads -> Select Product Line -> Select Desired Document Viega products are designed to be installed by licensed and trained plumbing and mechanical professionals who are familiar with our products’ proper use and installation. Installation by non-professionals may void Viega LLC’s warranty. Hydraulic Summary Report Description: Residential Job Number: CH0357 Node Flow(gpm) Total Hose Streams 250.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi)(gpm) (psi)(gpm) (psi) (psi)@@Name 8 128.338 111.179 17.1591381.00 250.00 55.310 133.000 301.84 Water Supply Design Engineer Job Number Total Water Required (Including Hose Allowance) 301.84 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 250.00 Hose Allowance At Source Supplies 164.17gal Residential 0.100gpm/ft² 256.00ft² 512.00ft² (Actual 196.75ft²) 2 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 104.834 Volume capacity of Dry PipesVolume capacity of Wet Pipes 5.61 between nodes 8 and 12 Maximum Velocity Under Ground 19.03 between nodes 54 and 38 Maximum Velocity Above Ground 4.2 K-Factor 25.60 at 37.152 Most Demanding Sprinkler Data System 354 Beaver Dam RoadVail, Colorado Job Site/Building VAIL FIRE354 Beaver Dam Road AHJ 032354 Beaver Dam Road Job State Certification/License NumberJob Name: STEVE ALLENCH0357 Contractor Contractor Number 032 Name of Contractor: Western States Fire Protection Address 1 274 Center Drive Address 2 Glenwood Springs, CO. 81601 Contact Name Contact Title PM ExtensionPhone 720-219-0574 FAX E-mail Steve.Allen@wsfp.us Web-Site Steve Allen Address 3 Address 1 Address 2 Drawing Name 354 Beaver Dam FP System Flow Demand 51.84 Remote Area(s) Address 3 81657 3/20/2018 © M.E.P.CAD, Inc. Page 2AutoSPRINK 2018 v14.0.3.0 11:23:36AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CH0357 Report Description: Residential • • • • • Route 1 • • • • • Pf Pe Pv DR 0.8110 25.60 15.90 0.476082 0'-4 0.824 511 23'-8 25.60 4.2 37.152 1'-4¾ -0.145 24 24'-0 37.831 1'-8¾ 150 Sprinkler, E(1'-4¾) Pf Pe Pv BL 1.0550 25.60 9.40 0.132243 12'-1¾ 2.632 24 24'-0 37.831 7'-9¼ 38 24'-0 40.464 19'-10¾ 150 5E(1'-6¾) Pf Pe Pv BL 1.0550 51.84 19.03 0.487822 37'-10¾ 24.547 38 24'-0 26.24 40.464 12'-5 1.734 54 20'-0 66.745 50'-3¾ 150 Flow (q) from Route 2 2T(4'-8), 2E(1'-6¾) Pf Pe Pv CM 1.0550 30.73 11.28 0.185437 11'-0¼ 4.058 54 20'-0 66.745 10'-10½ 63 20'-0 70.802 21'-10½ 150 E(1'-6¾), T(4'-8), C(4'-8) Pf Pe Pv FR 1.2910 34.50 8.46 0.085941 40'-7¾ 4.619 63 20'-0 3.77 70.802 13'-1¼ 4.335 344 10'-0 79.757 53'-9 150 Flow (q) from Route 4 3T(4'-4½) Pf Pe Pv CM 1.5270 51.84 9.08 0.080576 31'-10½ 14.009 344 10'-0 17.34 79.757 11'-8 3.035 358 3'-0 96.801 43'-6¾ 150 Flow (q) from Route 3 4E(2'-4), 2Tr(1'-2), BFP(-5.000), PRV(-5.500) Pf Pe Pv FR 2.0090 51.84 5.25 0.021183 2'-6 0.164 358 3'-0 96.801 5'-3 0.867 12 1'-0 97.832 7'-9 150 E(2'-7½), BV(-0.000), EE(2'-7½) Pf Pe Pv UG 1.9430 51.84 5.61 0.024925 220'-0 5.832 12 1'-0 97.832 14'-0 7.514 8 -3'-10 111.179 234'-0 150 2EE(2'-0), 2E(5'-0), S 301.84 250.00 Hose Allowance At Source 8 • • • • • Route 2 • • • • • Pf Pe Pv DR 0.8110 26.24 16.30 0.498336 0'-4 0.863 513 23'-8 26.24 4.2 39.033 1'-4¾ -0.145 33 24'-0 39.751 1'-8¾ 150 Sprinkler, E(1'-4¾) Pf Pe Pv BL 1.0550 26.24 9.63 0.138425 0'-6 0.713 33 24'-0 39.751 4'-8 38 24'-0 40.464 5'-1¾ 150 T(4'-8) • • • • • Route 3 • • • • • Pf Pe Pv CM 1.0550 21.11 7.75 0.092539 30'-6¾ 3.689 54 20'-0 30.73 66.745 9'-3¾ 154 20'-0 70.434 39'-10½ 150 Flow (q) from Route 1 2T(4'-8) Pf Pe Pv CM 1.0550 17.34 6.36 0.064302 44'-8½ 3.923 154 20'-0 70.434 16'-3½ 4.335 312 10'-0 78.692 61'-0¼ 150 Tr(0'-9¼), 3T(4'-8), E(1'-6¾) Pf Pe Pv CM 1.2910 17.34 4.25 0.024058 37'-8¼ 1.064 312 10'-0 78.692 6'-6½ 344 10'-0 79.757 44'-3 150 T(4'-4½), E(2'-2¼) • • • • • Route 4 • • • • • Pf Pe Pv CM 1.0550 3.77 1.38 0.003823 62'-2 0.368 154 20'-0 70.434 34'-1¾ 63 20'-0 70.802 96'-3¾ 150 T(4'-8) E(1'-6¾), 5T(4'-8), C(4'-8) 1.51 4.87) ( 150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc. 3/20/2018 Page 4AutoSPRINK 2018 v14.0.3.0 11:23:40AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CH0357 Report Description: Residential Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMVWater Meter Valve Z Cap © M.E.P.CAD, Inc. 3/20/2018 Page 5AutoSPRINK 2018 v14.0.3.0 11:23:40AM Device (gpm) Actual Flow Minimum Flow (gpm) (K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential Job Number: CH0357 Sprinkler 511 25.60 25.60 4.2 37.152 Sprinkler 513 26.24 25.60 4.2 39.033 Most Demanding Sprinkler Data © M.E.P.CAD, Inc. 3/20/2018 Page 3AutoSPRINK 2018 v14.0.3.0 11:23:38AM Hydraulic Overview Job Number: CH0357 Report Description: Residential Node Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi)Name 8 1381.00 250.00 133.000 55.310Water Supply Identifier Pressure(psi) K-Factor(K) Flow(gpm) Job System Supplies Check Point Gauges CH0357 STEVE ALLEN 354 Beaver Dam Road 354 Beaver Dam Road Vail, Colorado 720-219-0574 354 Beaver Dam FP 032 VAIL FIRE 354 Beaver Dam Road Job Name: Address 1 Address 2 Design Engineer Phone FAX State Certification/License Number AHJ Job Site/Building Most Demanding Sprinkler Data Coverage Per Sprinkler Total Demand Area of Application Hose Streams Number Of Sprinklers Calculated Pressure Result Job Number 301.84 @ 111.179 Water Supply at Node 8 (1381.00, 250.00, 133.000, 55.310) 0.100gpm/ft² 4.2 K-Factor 25.60 at 37.152 256.00ft² 512.00ft² (Actual 196.75ft²) 2 Density +17.159 (13.4%) Address 3 81657 System Pressure Demand System Flow Demand 111.179 51.84 250.00 © M.E.P.CAD, Inc. 3/20/2018 Page 1AutoSPRINK 2018 v14.0.3.0 11:23:33AM PERMIT FEE RECEIPT Case # F18-0013 Date Printed: 03/26/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0013 Status: Created Permit Number: Date Started: 03/21/2018 Permit Type: Fire - Construction Permit Subcases Fire Suppression Lot Number: 9 Property: 354 BEAVER DAM RD N (210107113037 N) (210107113037) Contacts Contact Type: Applicant Company Name: Western States Fire Protection Full Name: Steve Allen Address: 274 Center Drive Glenwood Springs, CO 81601 Email: steve.allen@wsfp.us Contact Type: Property Owner Full Name: PRICE, KENT A. & ANDREA L. Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $1,121.15 Fire Suppression Review Fee 001-0000.21123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Review Fee 03/26/2018 Check $432.00 Paid By: Western States Fire Protection - Notes: ck#420 124203 Fire Suppression Permit Fee 03/26/2018 Check $1,121.15 Paid By: Western States Fire Protection - Notes: ck#420 124203 FEE TOTAL $1,553.15 AMOUNT PAID $1,553.15 BALANCE DUE $0.00 03/26/2018 - 4:55:31 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1