HomeMy WebLinkAboutF18-0017_Approved Documents_1524497552.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspection Line: 970.479.2149
Fire - Construction Permit
F18-0017
Issued: 04/23/2018
TOWN OF VAIL
Property Information
Address: 660 LIONSHEAD PL ( 210107203999 )
Unit #:
Parcel Number: 210107203999
Legal Description:
Contacts
Contact Type: Applicant
Full Name: Jeremy Craig
Address: 10864 Wets CoCo Place Littleton, CO 80127 Phone: 9703933242
Contact Type: Property Owner
Full Name: Common Area
Address: Phone: None
Contractor
Contractor Type: Fire Protection
Company: Assurance Fire Systems, Inc.
State License #: 18-S-06113 Phone: 303-798-4448
Project Information
Project Name: Lion Square Lodge South 2018
Project Description: Relocate Fire sprinklers in conference room for new ceiling designs
Fees Paid
Account #: 001-0000.31111.00 - Fire Suppression Permit Fee Fee Amount: $327.25
Account #: 001-0000.21123.00 - Fire Suppression Review Fee Fee Amount: $432.00
Total Paid: $759.25
Conditions
Issued By: Town of Vail Fire and Emergency Services Department
NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
PERMIT FEE RECEIPT
Case # F18-0017
Date Printed: 04/17/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: F18-0017 Status: Created
Permit Number: Date Started: 04/13/2018
Permit Type: Fire - Construction Permit Subcases Fire Suppression
Lot Number: 1
Property: 660 LIONSHEAD PL (210107203999)
Contacts
Contact Type: Applicant
Company Name: Assurance Fire Systems
Full Name: Jeremy Craig
Address: 10864 Wets CoCo Place Littleton, CO 80127
Email: jcraig@assurancefiresystems.com
Contact Type: Property Owner
Full Name: Common Area
Address:
Permit Fees
Fee Information Account Amount
Fire Suppression Permit Fee 001-0000.31111.00 $327.25
Fire Suppression Review Fee 001-0000.21123.00 $432.00
Payment Information Date Paid Payment Type Amount
Fire Suppression Review Fee 04/17/2018 Credit Card $432.00
Paid By: - Notes: Visa - Jeremy Craig
Fire Suppression Permit Fee 04/17/2018 Credit Card $327.25
Paid By: - Notes: Visa - Jeremy Craig
FEE TOTAL $759.25
AMOUNT PAID $759.25
BALANCE DUE $0.00
04/17/2018 - 10:37:36 AM - Generated by: dcouch75 South Frontage Road West, Vail, Colorado 81657
1 / 1
10864 WEST COCO PLACE
LITTLETON, CO 80127
Tel: (303) 798-4448
Fax: (720) 922-7698
Chris@AssuranceFireSystems.com
FIRE SPRINKLER
PRODUCT SUMITTALS
FOR
Hyatt Place at Depot Square
3151 Pearl Street
Boulder, CO
LIONSSQUARE LODGE
660 W. LIONSHEAD PLACE
VAIL,CO
microfast® and
microfastHP® quick
resPonse uPrigHt and
conventional sPrinklers
tecHnical data
June 28, 2013
the viking corporation, 210 n industrial Park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
1. descriPtion
Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old
Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in
several different finishes, temperature ratings, and K-Factors to meet design require-
ments. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel
PTFE (ENT) coatings can be used in decorative applications where colors are desired.
In addition, these coatings have been investigated for installation in corrosive atmos-
pheres and are listed/approved as corrosion resistant as indicated in the Approval
Charts. (Note: fm global approves the ent coating as corrosion resistant. FM
Global has no approval classification for PTFE and Polyester coatings as corrosion
resistant.)
2. listings and aPProvals
culus listed: Category VNIV
fm approved: Classes 2002 and 2020
nYc approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16
aBs certified: Certificate 04-HS407984B-PDA
vds approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020
lPc approved: Ref. No. 096e/03, TE30401, and TE30872
ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131,
0786-CPD-40171, and 0786-CPD-40278
med certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008
note: Other International approval certificates are available upon request.
Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and
Design Criteria on page 51e for FM Approval requirements that must be followed.
3. tecHnical data
specifications:
Available since 1987.
Minimum Operating Pressure: 7 psi (0.5 bar)*
maximum Working Pressure: sprinklers vk315 and vk340 are rated for
use with water working pressures ranging from the minimum 7 psi (0.5
bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure
(HP) sprinklers can be identified by locating “250” stamped on the de-
flector. all other Part nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp.
Factory tested hydrostatically to 500 psi (34.5 bar)
Testing: U.S.A. Patent No. 4,831,870
Thread size: Refer to the Approval Charts
Nominal K-Factor: Refer to the Approval Charts
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: Refer to the Approval Charts
*cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE
Approvals ONLY is 5 psi (0.35 bar).
material standards:
Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all
other sprinklers.
Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper UNS-C19500 for
Sprinklers 06665B, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers.
Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000
Bulb: Glass, nominal 3 mm diameter
Form No. F_080488
viking technical data may be found on
the viking corporation’s Web site at
http://www.vikinggroupinc.com.
the Web site may include a more recent
edition of this technical data Page.
Sprinkler 51a
Replaces page 51a-e, dated June 11, 2013.
(ENT finish is no approved as corrosion resistant.)
tecHnical data
June 28, 2013
the viking corporation, 210 n industrial Park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
microfast® and
microfastHP® quick
resPonse uPrigHt and
conventional sPrinklers
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated
For Polyester Coated Sprinklers: Belleville Spring-Exposed
For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated.
ordering information: (Also refer to the current Viking price list.)
Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for
the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N, ENT = JN
Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G
For example, sprinkler VK300 with a 1/2” thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB
available finishes and temperature ratings: Refer to Table 1.
accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.)
sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000)
sprinkler cabinets:
A. Six-head capacity: Part No. 01724A (available since 1971)
B. Twelve-head capacity: Part No. 01725A (available since 1971)
4. installation
Refer to appropriate NFPA Installation Standards.
5. oPeration
During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
6. insPections, tests and maintenance
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. availaBilitY
The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic
and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. guarantee
For details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
Sprinkler 51b
taBle 1: availaBle sPrinkler temPerature ratings and finisHes
sprinkler temperature
classification
sprinkler nominal
temperature rating1
maximum ambient
ceiling temperature2 Bulb color
Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange
Ordinary 155 °F (68 °C) 100 °F (38 °C) Red
Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow
Intermediate 200 °F (93 °C) 150 °F (65 °C) Green
High 286 °F (141 °C) 225 °F (107 °C) Blue
sprinkler finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT
corrosion-resistant coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F
(57 °C)
footnotes
1 The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e. These tests
cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible
with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note
that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated.
microfast® and
microfastHP® quick
resPonse uPrigHt and
conventional sPrinklers
tecHnical data
June 28, 2013
the viking corporation, 210 n industrial Park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
approval chart 1 (ul)
microfast® and microfastHP® quick response
upright and conventional sprinklers
maximum 175 Psi (12 bar) WWP
Base Part
number1 sin thread size nominal k-factor overall length listings and approvals3
(refer also to design criteria on page 51d.)
nPt BsP u.s. metric2 inches mm culus4 nYc8 vds lPcB
upright-standard orifice
12978 VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A1, B4 See Footnote 7. -- -- -- --
07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 -- -- A2 A2 B212 B215
conventional-standard orifice
06766B VK310 1/2” 15 mm 5.6 80.6 2-3/16 56 A2 A2 -- A2 B212 B215
upright-large orifice
06665B VK350 3/4” -- 8.0 115.2 2-5/16 59 A1, B4 A1 A2 A2 B212 --
14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A1, B4 A1 A2 A2 B212 --
06764B16 VK350 1/2” 15 mm 8.0 115.2 2-5/16 59 A1, B4 A1 A2 -- A213 --
conventional-large orifice
06768B VK354 3/4” 20 mm 8.0 115.2 2-5/16 59 A1 A2 -- A2 B212 --
upright-small orifice11
06717B11 VK325 1/2” 15 mm 2.8 40.3 2-3/16 56 A1 A1 -- -- -- --
06719B11 VK327 1/2” 15 mm 4.2 57 2-3/16 56 A1 A1 -- -- -- --
06931B11 VK327 -- 10 mm 4.2 57 2-3/16 56 -- -- A2 -- C314 --
maximum 250 Psi (17 bar) WWP
upright-standard orifice
Base Part
number1 sin thread size nominal k-factor overall length listings and approvals3
(refer also to design criteria on page 51d.)
nPt BsP u.s. metric2 inches mm culus4 nYc9 vds lPcB
12281 VK315 1/2” 15 mm 5.6 80.6 2-3/16 56 A1 A1 -- -- -- --
upright-small orifice10
1228611 VK340 1/2” 15 mm 2.8 40.3 2-3/16 56 A1 A1 -- -- -- --
approved temperature ratings
A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and
286 °F (141°C)
B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C)
C - 155 °F (68 °C)
approved finishes
1 - Brass, Chrome, White Polyester5,6, Black Polyester5,6, and
Black PTFE5
2 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6
3 - Brass and Chrome
4 - ENT5
footnotes
1 Base part number is shown. For complete part number, refer to Viking’s current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.
5 cULus Listed as corrosion resistant.
6 Other colors are available on request with the same Listings and Approvals as the standard colors.
7 Meets New York City requirements, effective July 1, 2008.
8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA.
9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16.
10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only.
exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized.
11The sprinkler orifice is bushed.
12 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003.
13 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278.
14 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131.
15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008.
16 The 1/2” NPT Large Orifice Sprinkler is Listed and Approved for retrofit only
Sprinkler 51c
tecHnical data
June 28, 2013
the viking corporation, 210 n industrial Park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
microfast® and
microfastHP® quick
resPonse uPrigHt and
conventional sPrinklers
Sprinkler 51d
figure 1:
standard sprinkler Wrench 10896W/B
design criteria - ul
(Also refer to Approval Chart 1 on page 51c)
culus listing requirements:
Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in
accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers.
Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the
installation standards being applied, with hydraulically calculated wet systems only).
The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to
the installation guidelines for old style (conventional) sprinklers.
•
•
imPortant: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page
qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in accor-
dance with the latest edition of viking technical data, the appropriate standards of nfPa, lPcB, aPsad, vds
or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,
whenever applicable.
microfast® and
microfastHP® quick
resPonse uPrigHt and
conventional sPrinklers
tecHnical data
June 28, 2013
the viking corporation, 210 n industrial Park drive, Hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com
Sprinkler 51e
design criteria - fm
(Also refer to Approval Chart 2 above.)
fm approval requirements:
The sprinklers indicated in Approval Chart 2 are FM Approved as quick response non-storage upright sprinklers as indicated in the FM Approval Guide.
For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM
Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope
and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling.
note: the fm installation guidelines may differ from culus and/or nfPa criteria.
imPortant: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page
qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac-
cordance with the latest edition of viking technical data, the appropriate standards of nfPa, fm global, lPcB,
aPsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
approval chart 2 (fm)
microfast® quick response upright sprinklers
maximum 175 Psi (12 bar) WWP
Base Part
number1 sin thread size nominal k-factor overall length fm approvals3
(refer also to design criteria below.)nPt BsP u.s. metric2 inches mm
standard orifice
12978 VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A2, B3
07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2
large orifice
06665B VK350 3/4” -- 8.0 115.2 2-5/16 59 A2, B3
14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2, B3
06764B7 VK350 1/2” 15 mm 8.0 115.2 2-5/16 59 A2, B3
small orifice4
06717B6 VK325 1/2” 15 mm 2.8 40.3 2-3/16 56 A1
approved temperature ratings
A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C)
B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C)
approved finishes
1 - Brass and Chrome
2 - Brass, Chrome, White Polyester5, and Black
Polyester5
3 - ENT8
footnotes
1 Base part number is shown. For complete part number, refer to Viking’s current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals.
4 FM Approved as quick response non-storage pendent sprinklers. For specific application and installation requirements, reference the latest appli-
cable FM Loss Prevention Data Sheets (including Data Sheet 2-0).
5 Other colors are available on request with the same Approvals as the standard colors.
6 The sprinkler orifice is bushed.
7 The 1/2” NPT Large Orifice Sprinkler is Listed and Approved for retrofit only
8 FM approved as corrosion resistant.
mirage® standard and
Qr concealed pendent
sprinkler vk462 and hp
sprinkler vk463 (k5.6)
technical data
Form No. F_103005 16.07.28 Rev 16.1
Page 1 of 6
the viking corporation, 210 n industrial park drive, hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page.
1. description
Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462
and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for
installation on concealed pipe systems where the appearance of a smooth ceiling is
desired.
The sprinkler is pre-assembled with a threaded adapter for installation with a low-
profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The
two-piece design allows installation and testing of the sprinkler prior to installation of
the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assem-
bly allows easy installation of the cover plate after the system has been tested and the
ceiling finish has been applied. The cover assembly can be removed and reinstalled,
allowing temporary removal of ceiling panels without taking the sprinkler system out of
service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been
investigated for installation in corrosive atmospheres and is cULus Listed as corrosion
resistant as indicated in the Approval Charts. The ENT finish is only available for the
sprinkler assembly, the cover plate is not plated.
2. listings and approvals
cUlus listed: Category VNIV
Fm approval: Class 2015
nYc approved: MEA 89-92-E, Volume 32
vds approved: Certificate G4080021
lpcB approved: Ref. No. 096e/12
ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032
cccF approved: Approved by the China Certification Center for Fire Products (CCCF)
Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria
on page for FM Approval requirements that must be followed.
3. technical data
Specifications:
Available since 2006.
Minimum Operating Pressure: 7 psi (0.5 bar)*
maximum Working pressure: sprinkler vk463 is rated for use with water working pressures ranging from the minimum
7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. high-pressure (hp) sprinklers can be identified by
locating “250” stamped on the deflector. sprinkler vk462 is rated to a maximum 175 psi (12 bar) wwp.
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 1/2” (15 mm) NPT
Nominal K-Factor: 5.6 U.S. (80.6 metric†)
Glass-bulb fluid temperature rated to -65°F (-55°C)
Patents Pending
*cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE
Approvals ONLY is 5 psi (0.35 bar).
†Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
material standards:
Sprinkler Body: Brass UNS-C84400
Deflector: Copper UNS-C19500 for Sprinkler VK462
Phosphor Bronze UNS-C51000 for Sprinkler VK463
Deflector Pins: Stainless Steel Alloy
Bulb: Glass, nominal 3 mm diameter
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
Button: Brass UNS-C36000
Screws: 18-8 Stainless Steel
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape
Yoke: Phosphor Bronze UNS-C51000
Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating
Replaces Form No. F_103005 Rev 15.1
(Added PNs for CCCF Approved sprinklers; upgraded graphics)
mirage® standard and
Qr concealed pendent
sprinkler vk462 and hp
sprinkler vk463 (k5.6)
technical data
Form No. F_103005 16.07.28 Rev 16.1
Page 2 of 6
the viking corporation, 210 n industrial park drive, hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page.
cover assembly materials:
Cover: Copper UNS-C11000
Base: Brass UNS-C26000 or UNS-C26800
Springs: Nickel Alloy
Solder: Eutectic
ordering information: (Also refer to the current Viking price list.)
Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately:
sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A
Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number:
Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E
For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB.
cover plate assembly: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16“ diameter), or Base Part No. 15394
(square cover plate, 3-5/16” diameter)
Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover
temperature rating to the base part number:
Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B,
Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B
Temperature Suffix: 135 °F (57 °C) UL (139 °F (59 °C) FM and LPCB) = A, 165 °F (74 °C) = C
For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC.
Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart.
available Finishes and temperature ratings: Refer to Table 1.
accessories: (Also refer to the Viking website.)
sprinkler Wrenches**:
A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or
B. Head Cabinet Wrench Part No. 14031*** (available since 2006)
C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover
(available since 2007)
**Requires a ½” ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets.
sprinkler cabinet: Part No. 01731A (available since 1971)
4. installation
Refer to appropriate NFPA Installation Standards.
5. operation
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches.
Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter,
releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector,
forming a uniform spray pattern to extinguish or control the fire.
6. inspections, tests and maintenance
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. availaBilitY
Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking
Corporation web site for the closest distributor or contact The Viking Corporation.
8. gUarantee
For details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
mirage® standard and
Qr concealed pendent
sprinkler vk462 and hp
sprinkler vk463 (k5.6)
technical data
Form No. F_103005 16.07.28 Rev 16.1
Page 3 of 6
the viking corporation, 210 n industrial park drive, hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page.
approval chart 1 (Ul)
mirage® concealed pendent sprinklers vk462 and vk463
sprinkler
Base part no.1 sin
npt thread
size
nominal
k-Factor
maximum
Water Working
pressure
listings and approvals4
(refer also to design criteria)
inch mm U.s. metric2 cUlus5 nYc vds7 lpcB
standard response applications
13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) -- -- AY1, CZ1 AY1, BZ1 AY1, CZ18 --
19785A VK462 1/2” -- 5.6 80.6 175 psi (12 bar) -- -- -- -- -- AY2, CZ2
Quick response applications
13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 -- -- -- --
13503JN11 VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 -- -- -- --
13667A VK463 1/2” 15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BW16 -- -- -- --
sprinkler temperature ratings
A - 155 °F (68 °C)
B - 175 °F (79 °C) and 200 °F (93 °C)
C - 200 °F (93 °C)
cover plate assembly temperature ratings9
V - 135 °F (57 °C) cULus Listed cover 135041, 136421 (large diam-
eter), or 153941 (square cover plate)
W - 165 °F (74 °C) cover 135041 or 136421 (large diameter)
X - 165 °F (74 °C) cover 135041, or 136421 (large diameter)
Y - 135 °F (57 °C) cover 135041 LPCB Approved as 139 °F (59 °C)
Z - 165 °F (74 °C) cover 135041
cover plate assembly Finishes10
1 - Polished Chrome, Brushed Chrome, Bright Brass,
Antique Brass, Brushed Brass, Brushed Copper,
Painted White, Painted Ivory, or Painted Black
2 - Brass
Footnotes
1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3 The Water Working Pressure rating is stamped on the deflector.
4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional ap-provals.
5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada.
6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32.
7 VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021.8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032.9 The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label.
10Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approv-als apply for any paint manufacturer. Contact Viking for additional information.
11 cULus Listed as corrosion resistant.
note: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1.
taBle 1: availaBle sprinkler temperatUre ratings and Finishes
sprinkler temperature
classification
sprinkler nominal
temperature rating1
maximum ambient
ceiling temperature2
temperature rating of cover
assembly (required)Bulb color
Ordinary 155 °F (68° C) 100 °F (38 °C)135 °F (57 °C) cULus
139 °F (59 °C) FM and LPCB Red
Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow
Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green
cover plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory,
or Painted Black
sprinkler Finishes: Brass and ENT
corrosion resistant coatings3: ENT
Footnotes
1 The sprinkler temperature rating is stamped on the sprinkler deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-
ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the
waterway, but the Belleville spring is exposed.
mirage® standard and
Qr concealed pendent
sprinkler vk462 and hp
sprinkler vk463 (k5.6)
technical data
Form No. F_103005 16.07.28 Rev 16.1
Page 4 of 6
the viking corporation, 210 n industrial park drive, hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page.
design criteria - Ul
(Also refer to Approval Chart 1)
cUlus listing requirements:
Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition ofNFPA 13 for standard coverage pendent spray sprinklers as indicated below.
• For hazard occupancies up to and including Ordinary Hazard, Group II.
• Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m).
• Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13.
• Minimum distance from walls is 4 in. (102 mm).
• Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measuredperpendicular to the wall.
• The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed.
note: concealed sprinklers must be installed in neutral or negative pressure plenums only.
vds approval requirements:
a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials.
b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight.
c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan-cies, except in OH4.
notes: Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which the false ceiling space is protected by a
water extinguishing system.
Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which during a fire the pressure above the false ceiling
may be assumed to be higher than the pressure below the false ceiling.
The criterion for the dropping of the cover relevant for this approval is heat.
Steps of installation:
1. Prepare the sprinkler key.
2. Remove the plastic cover.
3. Hold the sprinkler with the wrench and fasten it.
4. Replace the plastic cover and do not remove until the cover is installed.
important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to Bulletin
Form no. F_080614 for general care, installation, and maintenance information. viking sprinklers are to be in-
stalled in accordance with the latest edition of viking technical data, the appropriate standards of nFpa, lpcB,
apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Figure 1: identification of custom paint for concealed covers
All custom color painted cover plates will have an
identifying label affixed to the inside of the cover that
indicates the custom color and will have a representative
sample (a paint dot) of the paint on the label.FACTORY APP L IE D CUSTO
M
PAI
NT COLORFigure 2: square cover assembly 15394
3-5/16” (84 mm)
mirage® standard and
Qr concealed pendent
sprinkler vk462 and hp
sprinkler vk463 (k5.6)
technical data
Form No. F_103005 16.07.28 Rev 16.1
Page 5 of 6
the viking corporation, 210 n industrial park drive, hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page.
design criteria - Fm
(Also refer to Approval Chart 2 above.)
Fm approval requirements:
Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response non-storage concealed pendent sprinkler as indicated in the FM
Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data
Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic
design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling.
note: the Fm installation guidelines may differ from cUlus and/or nFpa criteria.
important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to page
sr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac-
cordance with the latest edition of viking technical data, the appropriate standards of nFpa, Fm global, lpcB,
apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
approval chart 2 (Fm)
mirage® standard response concealed pendent sprinkler vk462
sprinkler Base
part no.1 sin npt thread size nominal k-Factor maximum
Water Working
pressure
Fm approvals3
(refer also to design criteria below.)inch mm U.s. metric 2
13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AW1, BX1
sprinkler temperature ratings
A - 155 °F (68 °C)
B - 175 °F (79 °C) and 200 °F (93 °C)
cover plate assembly temperature ratings4
W - 139 °F (59 °C) cover 135041, 136421 (large diameter),
or 153941 (square cover plate)
X - 165 °F (74 °C) cover 135041, 136421 (large diameter), or
153941 (square cover plate)
cover plate assembly Finishes5
1 - Polished Chrome, Brushed Chrome, Bright
Brass, Antique Brass, Brushed Brass,
Brushed Copper, Painted White, Painted
Ivory, or Painted Black
Footnotes
1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional
approvals.
4 The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label.
5 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors.
Listings and approvals apply for any paint manufacturer. Contact Viking for additional information.
note: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1.
mirage® standard and
Qr concealed pendent
sprinkler vk462 and hp
sprinkler vk463 (k5.6)
technical data
Form No. F_103005 16.07.28 Rev 16.1
Page 6 of 6
the viking corporation, 210 n industrial park drive, hastings mi 49058
telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
visit the viking website for the latest edition of this technical data page.
sprinkler and
adapter assembly
• protective cap
removed
• Use wrench
14047W/B**
step 1:
carefully slide the
wrench sideways around
the deflector and pins
sprinkler Wrench
part no. 14047W/B**
** a 1/2” ratchet is required (not available from viking)
2-1/4” (57 mm)
diameter opening
required in the
ceiling.
step 2:
carefully press the wrench upward and
turn slightly to ensure engagement with
the sprinkler wrench flats.
Figure 3: sprinkler installation and proper Wrench Usage
never install the sprinkler by applying the installation
wrench across the frame arms. do not overtighten.
Use only the designated sprinkler wrenches, viking
part numbers 14047W/B** or 14031**. a leak tight seal
should be achieved by turning the sprinkler clockwise
1 to 1-1/2 turns beyond finger tight.
sprinkler
wrench flat
sprinkler
frame arms
Figure 4: sprinkler dimensions and cover installation
1/2” (15 mm) npt 2-3/16”(55 mm)2-9/16” (65 mm)
maximum 2-1/16” (52 mm)
minimum
2-3/4” (70 mm) or
3-5/16” (84 mm)note: Upon sprinkler activation, the deflector descends
to approximately 13/16” (21 mm) below the sprinkler body.
Replaces Form No. F_103005 Rev 15.1
(Added PNs for CCCF Approved sprinklers; upgraded graphics)
Eddy Flow
A company
1819 Clarkson Road
Chesterfield, MO 63017
(800) 325-4467
FAX: (636) 537-2645
www.bullmoosetube.com
e-mail: info@bullmoosetube.com
For additional information,
contact your salesperson today at
(800) 325-4467 or (636) 537-2600
in the USA, or from Canada
call (800) 882-4666
All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation.
3/01
The Cost Effective Replacement for Schedule 10
Realizing the growing need of fire protection systems
in commercial and residential construction, Bull
Moose Tube has added Eddy Flow to its
comprehensive line of sprinkler pipe products.
Eddy Flow is a specially engineered replacement for
schedule 10, offering better flow characteristics while
providing design flexibility. This product is FM
approved, as well as UL listed (for U.S. and Canada)
for roll grooving and welding. Please check with
appropriate sources for up-to-date listings and
approval information.
As an added benefit, it is more economical to use than
schedule 10 due to reduced delivery costs and ease
of handling. Furthermore, Eddy Flow’s larger ID
provides an opportunity for downsizing and further
cost savings.
COMPARISON
Inside Diameter C.R.R.*
NPS
(in)
O.D.
(in)
Eddy Flow
(in)
Sch. 10
(in)
Sch. 40
(in)
Eddy Flow Schedule 40
1-1/2
2
2-1/2
3
4
1.900
2.375
2.875
3.500
4.500
1.754
2.229
2.729
3.342
4.316
1.682
2.157
2.635
3.260
4.260
1.610
2.067
2.469
3.068
4.026
2.34
1.89
1.09
1.00
1.00
1.00
1.00
1.00
1.00
1.00
* Corrosion Resistance Ratio
BENEFITS
· Dual Certified to ASTM A135 and A795.
· FM approved for roll grooving and welding for use in wet systems.
· UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry,
preaction, and deluge type sprinkler systems.
· Lightweight - saves shipping costs, and offers easier handling.
· Can be used with roll grooved couplings or welded outlets for pressures up to 175 psi.
· Floor stock available in various lengths produced in Trenton (GA), Gerald (MO), and Masury (OH). Also can be
ordered in custom lengths.
· Can be supplied roll grooved or plain end.
· Can be used for wet and dry* systems.
* Eddy Flow can be hot dipped galvanized to meet FM’s requirement for dry systems.
PIPE PREPARATION
For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be
free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior
to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s
instructions for the specific fitting used.
S3 - 2
DYNA THREAD ®
With ABF
Protection
With ABF
Protection
ContentsNext Previous Return
S3 - 3
Comparison to L.W.T. PipesComparison to Schedule 40
Specifications & Approvals
Dyna-Thread ®
Full Line Sch-40 Replacement
Dyna-Thread® offers the life expectancy of Sch-40 with superior hydraulics and greater value.
Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety
and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages.
· Dyna-Thread’s inside diameter is up
to 3.6% larger than Sch-40 giving it
superior hydraulics. And, when used
in combination with Dyna-Flow pipe,
down sizing often occurs.
· Dyna-Thread is fully listed and
approved by UL, ULC, and FM for
fire sprinkler applications.
· The life expectancy of Dyna-Thread
and Sch-40 are equal based on the
calculated wall thicknesses per UL.
· The consistent quality of steel used to
make Dyna-Thread facilitates smooth
threading and lower maintenance
costs.
· The exterior of Dyna-Thread is
protected by a clean, durable mill
coating for extended shelf life and
easy paint application.
· More wall thickness at the thread
(CRR=1.00) gives Dyna-Thread
better life expectancy than lightwall
threadable pipe joints.
· Unlike lightwall threadable pipe,
Dyna-Thread has no thread gauge
warning.
· Dyna-Thread is approved for
standard hanger spacing (15 ft.
O.C.), can be used as earthquake
sway bracing, and is safe to use as
drops.
· Dyna-Thread is safer to weld on.
· Dyna-Thread is more widely
accepted than lightwall threadable
where Sch-40 is specified.
Super 40/Dyna-Thread pipe is
manufactured to meet: ASTM A-135,
Grade A and is in compliance with
NFPA-13. All sizes of Super 40/Dyna-
Thread are rated at 300 psi working
pressure. Super 40/Dyna-Thread is UL
and ULC Listed for wet, dry deluge and
pre-action sprinkler systems and FM
Approved for use in wet systems. Super
40/Dyna-Thread can be “hot-dip”
galvanized to meet FM requirement for
dry systems. Super 40/Dyna-Thread is
approved for all threaded couplings and
welded outlets and is suitable for all
roll-grooved, and plain-end fittings.
(See listing information).
Specifications
NPS Nominal I.D. Wt. Wt. (H2O Filled)Pcs/Wt/Lift (21') Wt/Lift (24') Wt/Lift (25')
In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg
1" 1.080 1.330 1.75 70 1955 2234 2327
25 27.4 2.0 2.60 70 887 1013 1056
11®4" 1.408 1.870 2.54 51 2002 2288 2384
32 35.8 2.8 3.78 51 908 1038 1081
11®2" 1.639 2.290 3.22 44 2115 2418 2519
40 41.6 3.4 4.79 44 959 1097 1143
2" 2.104 3.050 4.57 30 1921 2196 2287
50 53.4 4.5 6.80 30 871 996 1037
· With its increased strength and lighter
weight, Dyna-Thread reduces
installation fatigue and is ideal for
retro-fit applications.
Corrosion Resistance Ratio (CRR) is a
UL (Underwriters Laboratory) term for
the estimated life expectancy of a pipe
joint. This is based on the calculated
wall thickness at the base of the first
exposed thread, assumed to be the
weakest point of the pipe length. Dyna-
Thread and Sch-40 have the same
calculated wall thicknesses at this point
and are both assigned the same CRR of
1.00.
The internal surface of all black Allied
Tube & Conduit Fire Sprinkler pipe
products up to 4.5000” in diameter is
coated with our new Antibacterial
Formula, “ABF”. In scientific laboratory
test, ABS proved to have superior
resistance to microbial colonization of
pipe walls, thereby delaying or possibly
preventing the onset of
Microbiologically Influenced corrosion
(MIC) when the First Sprinkler System
is first installed.
FM
Listed Approved Listed
16100 S. Lathrop · Harvey, IL 60426
11350 Norcom Rd. · Philadelphia, PA 19154
2525 N. 27 th Ave. · Phoenix, AZ 85009
Customer Service:
(800) 882-5543
Fax 708-339-1806
ContentsNext Previous Return
THE COPPER TUBE HANDBOOK
CDA
Copper Development Association
Nominal or
Standard
Size, inches
Outside
Diameter
Inside
Diameter Cu ft Gal
Wall
Thickness
Contents of Tube
per linear ft
Cross
Sectional
Area of Bore,
sq inches
Weight
of Tube Only, pounds per linear ft
Weight
of Tube & Water, poundsper linear ft
Nominal Dimensions, inches Calculated Values (based on nominal dimensions)
3/8 .500 .450 .025 .159 .145 .214 .00110 .00826
1/2 .625 .569 .028 .254 .204 .314 .00176 .0132
3/4 .875 .811 .032 .517 .328 .551 .00359 .0269
1 1.125 1.055 .035 .874 .465 .843 .00607 .0454
11/4 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681
11/2 1.625 1.527 .049 1.83 .940 1.73 .0127 .0951
2 2.125 2.009 .058 3.17 1.46 2.83 .0220 .165
21/2 2.625 2.495 .065 4.89 2.03 4.14 .0340 .254
3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363
31/2 3.625 3.459 .083 9.40 3.58 7.64 .0653 .488
4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634
5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982
6 6.125 5.881 .122 27.2 8.92 20.7 .189 1.41
8 8.125 7.785 .170 47.6 16.5 37.1 .331 2.47
10 10.125 9.701 .212 73.9 25.6 57.5 .513 3.84
12 12.125 11.617 .254 106 36.7 82.5 .736 5.51
Nominal or
Standard
Size, inches Outside
Diameter
Inside
Diameter Cu ft Gal
Wall
Thickness
Contents of Tube
per linear ft
Cross
Sectional
Area of Bore,
sq inches
Weight of Tube Only,
pounds
per linear ft
Weight of Tube & Water,
pounds
per linear ft
Nominal Dimensions, inches Calculated Values (based on nominal dimensions)
11/4 1.375 1.295 .040 1.32 .650 1.22 .00917 .0686
11/2 1.625 1.541 .042 1.87 .809 1.62 .0130 .0971
2 2.125 2.041 .042 3.27 1.07 2.48 .0227 .170
3 3.125 3.030 .045 7.21 1.69 4.81 .0501 .375
4 4.125 4.009 .058 11.6 2.87 7.88 .0806 .603
5 5.125 4.981 .072 19.5 4.43 12.9 .135 1.01
6 6.125 5.959 .083 27.9 6.10 18.2 .194 1.45
8 8.125 7.907 .109 49.1 10.6 31.8 .341 2.55
22
TABLE 2c. Dimensions and Physical Characteristics of Copper Tube: TYPE M
TABLE 2d. Dimensions and Physical Characteristics of Copper Tube: DMV (Drain, Waste and Vent)
26
TABLE 3c. Rated Internal Working Pressure for Copper Tube:TYPEM*
TABLE 3d. Rated Internal Working Pressure for Copper Tube: DWV*
NOTE: *Based on maximum allowable stress in tension (psi) for the indicated temperatures (°F), see page 12.
**When brazing or welding is used to join drawn tube, the corresponding annealed rating must be used, see page 12.
***Types M and DWV are not normally available in the annealed temper. Shaded values are provided for guidance when drawn temper tube
is brazed or welded, see page 12.
Nominal
Size, in
S=
6000 psi
100 F
S=
5100 psi
150 F
S=
4900 psi
200 F
S=
4800 psi
250 F
S=
4700 psi
300 F
S=
4000 psi
350 F
Annealed*** Drawn**
1/4
3/8 570 485 466 456 447 380 285 982 982 982 982 953 925 896
1/2 494 420 403 395 387 329 247 850 850 850 850 825 800 776
5/8
3/4 407 346 332 326 319 271 204 701 701 701 701 680 660 639
1 337 286 275 270 264 225 169 580 580 580 580 563 546 529
11/4 338 287 276 271 265 225 169 582 582 582 582 565 548 531
11/2 331 282 270 265 259 221 166 569 569 569 569 553 536 520
2 299 254 244 239 234 199 149 514 514 514 514 499 484 469
S=
3000 psi
400 F
S=
10,300 psi
100 F
S=
10,300 psi
150 F
S=
10,300 psi
200 F
S=
10,300 psi
250 F
S=
10,000 psi
300 F
S=
9,700 psi
350 F
S=
9,400 psi
400 F
21/2 274 233 224 219 215 183 137 471 471 471 471 457 444 430
3 253 215 207 203 199 169 127 435 435 435 435 423 410 397
31/2 252 214 206 202 197 168 126 433 433 433 433 421 408 395
4 251 213 205 201 197 167 126 431 431 431 431 419 406 394
5 233 198 190 186 182 155 116 400 400 400 400 388 377 365
6 218 186 178 175 171 146 109 375 375 375 375 364 353 342
8 229 195 187 183 180 153 115 394 394 394 394 382 371 359
10 230 195 188 184 180 153 115 394 394 394 394 383 371 360
12 230 195 188 184 180 153 115 395 395 395 395 383 372 360
NominalSize, in
S=
6000 psi
100 F
S=
5100 psi
150 F
S=
4900 psi
200 F
S=
4800 psi
250 F
S=
4700 psi
300 F
S=
4000 psi
350 F
Annealed*** Drawn**
11/4 330 280 269 264 258 220 165 566 566 566 566 549 533 516
11/2 293 249 240 235 230 196 147 503 503 503 503 489 474 459
2 217 185 178 174 170 145 109 373 373 373 373 362 352 341
3 159 135 130 127 125 106 80 273 273 273 273 265 257 249
4 150 127 122 120 117 100 75 257 257 257 257 250 242 235
5 151 129 124 121 119 101 76 260 260 260 260 252 245 237
6 148 126 121 119 116 99 74 255 255 255 255 247 240 232
8 146 124 119 117 114 97 73 251 251 251 251 244 236 229
S=
3000 psi
400 F
S=
10,300 psi
100 F
S=
10,300 psi
150 F
S=
10,300 psi
200 F
S=
10,300 psi
250 F
S=
10,000 psi
300 F
S=
9,700 psi
350 F
S=
9,400 psi
400 F
** Cast Bronze Only *Factory Optionconsult factory for price and delivery information. Elkhart Products Corporation 11
Wrot & Cast Pressure Fittings
Tees
Nominal Size Box Master Approx. Dim. Dim. Dim.
In Inches Quantity Pack Net Wt. A B C
3/4 x 3/4 x 1/2 25 250 0.109 25/64 25/64 19/32
3/4 x 3/4 x 3/8 25 250 0.130 25/64 25/64 11/16
3/4 x 3/4 x 1/4 25 250 0.135 25/64 25/64 3/4
* 3/4 x 5/8 x 5/8 25 250 0.150 1/2 11/16 3/4
3/4 x 1/2 x 3/4 25 250 0.144 1/2 25/32 17/32
3/4 x 1/2 x 1/2 25 250 0.109 25/64 5/8 19/32
* 3/4 x 1/2 x 3/8 25 250 0.137 25/64 5/8 11/16
3/4 x 1/2 x 1/4 25 250 0.140 25/64 5/8 3/4
* 3/4 x 3/8 x 3/4 25 250 0.159 1/2 29/32 17/32
* 3/4 x 3/8 x 1/2 25 250 0.140 25/64 23/32 19/32
* 3/4 x 3/8 x 3/8 25 250 0.132 25/64 23/32 11/16
1 x 1 x 1 1/2 5 50 0.680 1 1/4 1 1/4 1 5/32
1 x 1 x 1 1/4 5 50 0.405 1 5/32 1 5/32 31/32
1 x 1 x 3/4 10 100 0.223 1/2 1/2 5/8
* 1 x 1 x 5/8 10 100 0.319 1/2 1/2 15/16
1 x 1 x 1/2 10 100 0.186 23/64 23/64 11/16
1 x 1 x 3/8 10 100 0.185 23/64 23/64 13/16
1 x 3/4 x 1 10 100 0.290 21/32 53/64 21/32
1 x 3/4 x 3/4 10 100 0.220 1/2 11/16 5/8
1 x 3/4 x 1/2 10 100 0.185 23/64 9/16 11/16
* 1 x 3/4 x 3/8 10 100 0.270 23/64 9/16 13/16
* 1 x 5/8 x 5/8 10 100 0.313 1/2 11/16 15/16
* 1 x 5/8 x 1/2 10 100 0.272 23/64 9/16 11/16
1 x 1/2 x 1 10 100 0.290 21/32 5/64 21/32
1 x 1/2 x 3/4 10 100 0.220 1/2 15/16 5/8
1 x 1/2 x 1/2 10 100 0.185 23/64 13/16 11/16
1 x 1/2 x 3/8 10 100 0.185 23/64 13/16 13/16
1 1/4 x 1 1/4 x 2 5 40 1.352 1 3/4 1 3/4 1 3/8
1 1/4 x 1 1/4 x 1 1/2 5 50 0.680 1 3/16 1 3/16 1 5/32
1 1/4 x 1 1/4 x 1 5 50 0.348 17/32 17/32 25/32
1 1/4 x 1 1/4 x 3/45 50 0.301 7/16 7/16 3/4
1 1/4 x 1 1/4 x 1/25 50 0.259 19/64 19/64 11/16
1 1/4 x 1 x 1 1/4 5 50 0.405 7/8 7/8 25/32
1 1/4 x 1 x 1 5 50 0.391 3/4 3/4 25/32
1 1/4 x 1 x 3/4 5 50 0.297 5/8 5/8 25/32
1 1/4 x 1 x 1/2 5 50 0.256 1/2 1/2 25/32
1 1/4 x 3/4 x 1 1/45 50 0.405 7/8 7/8 25/32
1 1/4 x 3/4 x 1 5 50 0.391 3/4 3/4 25/32
1 1/4 x 3/4 x 3/4 5 50 0.297 5/8 5/8 25/32
1 1/4 x 3/4 x 1/2 5 50 0.256 1/2 1/2 25/32
1 1/4 x 1/2 x 1 1/45 50 0.405 7/8 7/8 25/32
**1 1/4 x 1/2 x 1 12 72 0.470 - - -
1 1/2 x 1 1/2 x 2 5 50 1.352 1 37/64 1 37/64 1 3/8
1 1/2 x 1 1/2 x 1 1/4 5 50 0.482 11/16 11/16 13/16
1 1/2 x 1 1/2 x 1 5 50 0.387 9/16 9/16 13/16
1 1/2 x 1 1/2 x 3/45 50 0.342 7/16 7/16 13/16
1 1/2 x 1 1/2 x 1/25 50 0.310 21/64 21/64 29/32
1 1/2 x 1 1/4 x 1 1/2 5 50 0.680 1 7/32 1 3/16 1 7/32
1 1/2 x 1 1/4 x 1 1/45 50 0.661 31/32 1 3/16 1 1/16
1 1/2 x 1 1/4 x 1 5 50 0.591 27/32 1 3/16 1 1/16
1 1/2 x 1 1/4 x 3/45 50 0.583 11/16 7/8 31/32
1 1/2 x 1 1/4 x 1/25 50 0.460 9/16 13/16 31/32
Nominal Size Box Master Approx. Dim. Dim. Dim.
In Inches Quantity Pack Net Wt. A B C
1/8 50 1000 0.014 13/64 13/64 7/32
5/16 OD 50 1000 0.020 7/32 7/32 9/32
1/4 50 1000 0.028 17/64 17/64 1/4
3/8 50 500 0.045 5/16 5/16 3/8
1/2 50 500 0.056 21/64 21/64 11/32
5/8 25 250 0.110 7/16 7/16 1/2
3/4 25 250 0.144 1/2 1/2 17/32
1 10 100 0.291 21/32 21/32 21/32
1 1/4 5 50 0.397 41/64 41/64 41/64
1 1/2 5 50 0.540 13/16 13/16 13/16
2 5 40 1.082 1 1/16 1 1/16 1 15/64
2 1/2 1 10 1.967 1 21/32 1 21/32 1 11/16
3 1 10 2.744 1 7/8 1 7/8 1 11/16
3 1/2 1 8 4.167 2 5/32 2 5/32 2 1/4
4 1 8 6.396 2 13/32 2 13/32 2 9/16
* 5 1 1 7.998 2 37/64 2 37/642 29/32
* 6 1 1 12.613 3 1/8 3 1/8 3 11/16
* 8 1 1 32.086 4 1/16 4 1/16 4 3/4
* 3/8 x 3/8 x 3/16 OD50 1000 0.028 17/64 17/64 7/16
1/8 x 1/8 x 1/4 50 1000 0.028 13/32 13/32 1/4
1/4 x 1/4 x 1/2 50 500 0.063 21/32 21/32 11/32
1/4 x 1/4 x 3/8 50 500 0.045 15/32 15/32 3/8
1/4 x 1/4 x 1/8 50 1000 0.028 17/64 17/64 13/32
1/4 x 1/8 x 1/4 50 1000 0.028 17/64 13/32 1/4
1/4 x 1/8 x 1/8 50 1000 0.028 17/64 13/32 13/32
3/8 x 3/8 x 1/2 50 500 0.063 17/32 17/32 11/32
3/8 x 3/8 x 1/4 50 500 0.045 5/16 5/16 15/32
3/8 x 3/8 x 1/8 50 500 0.045 5/16 5/16 39/64
* 3/8 x 1/4 x 1/2 50 500 0.063 17/32 21/32 11/32
3/8 x 1/4 x 1/4 50 500 0.045 5/16 15/32 15/32
* 3/8 x 1/4 x 1/8 50 500 0.045 5/16 15/32 5/8
3/8 x 1/8 x 3/8 50 500 0.045 5/16 9/16 3/8
1/2 x 1/2 x 1 10 100 0.290 15/16 15/16 3/4
1/2 x 1/2 x 3/4 25 250 0.118 33/64 33/64 15/32
1/2 x 1/2 x 3/8 50 500 0.061 5/16 5/16 13/32
1/2 x 1/2 x 1/4 50 500 0.061 9/32 9/32 13/32
1/2 x 1/2 x 1/8 50 500 0.061 9/32 9/32 1/2
1/2 x 3/8 x 1/2 50 500 0.063 3/8 17/32 11/32
1/2 x 3/8 x 3/8 50 500 0.061 5/16 1/2 13/32
1/2 x 1/4 x 1/4 50 500 0.061 9/32 5/8 13/32
3/4 x 3/4 x 1 10 100 0.202 3/4 3/4 17/32
* 3/4 x 3/4 x 5/8 25 250 0.153 1/2 1/2 3/4
WROT CAST
111 Tee-cont. 4711
Copper to Copper to Copper
B
C
A C x C x C
WROT CAST
111 Tee 4711
Copper to Copper to Copper
Nominal Size Box Master Approx. Dim. Dim.
In Inches Quantity Pack Net Wt. A B
1/8 50 1000 0.006 1/4 1/4
1/4 50 1000 0.012 3/8 3/8
3/8 50 1000 0.026 13/32 13/32
1/2 100 1000 0.039 25/64 25/64
5/8 25 250 0.069 17/32 17/32
3/4 50 500 0.087 9/16 9/16
1 20 200 0.168 47/64 47/64
1 1/4 25 200 0.300 15/16 15/16
1 1/2 20 120 0.404 1 11/64 1 11/64
2 10 80 0.748 1 29/64 1 29/64
2 1/2 5 40 1.200 1 21/32 1 21/32
3 3 24 1.920 1 61/64 1 61/64
3 1/2 1 8 2.728 2 7/32 2 7/32
4 1 8 4.290 2 17/32 2 17/32
5 1 1 8.586 3 1/8 3 1/8
6 1 1 15.200 3 13/16 3 13/16
8 1 1 37.000 5 1/8 5 1/8
Wrot & Cast Pressure Fittings
Elbows
8 Elkhart Products Corporation Asubsidiary of Amcast Industrial Corporation ** Cast Bronze Only *Factory Optionconsult factory for price and delivery information.
Nominal Size Box Master Approx. Dim. Dim.
In Inches Quantity Pack Net Wt. A B
1/4 50 1000 0.013 15/64 41/64
3/8 50 1000 0.024 9/32 23/32
1/2 100 1000 0.035 5/16 25/32
5/8 25 250 0.059 27/64 1 1/16
3/4 50 500 0.076 13/32 1 3/16
1 25 250 0.134 7/16 1 7/16
1 1/4 25 200 0.229 17/32 1 9/16
1 1/2 20 160 0.343 19/32 1 3/4
2 10 80 0.625 25/32 2 3/16
2 1/2 5 40 0.965 29/32 2 7/16
3 3 24 1.470 1 2 11/16
*3 1/2 1 16 2.100 1 5/32 3
4 1 8 3.340 1 9/32 3 1/2
WROT CAST
106-2 45°Street Elbow
Fitting to Copper
B
A
A
B
FTG. x C
C x C
WROT CAST
107-C 90°Elbow-Close Ruff 4707
Copper to Copper
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
1/4 50 1000 0.013 15/64
3/8 50 1000 0.024 1/4
1/2 100 1000 0.036 17/64
5/8 25 250 0.063 7/16
3/4 50 500 0.077 3/8
1 25 250 0.137 13/32
1 1/4 25 200 0.229 33/64
1 1/2 20 160 0.343 19/32
2 10 80 0.625 25/32
2 1/2 5 40 0.970 7/8
3 3 24 1.460 63/64
3 1/2 1 16 2.180 1 5/32
4 1 8 3.376 1 11/64
5 1 6 6.564 1 13/32
6 1 1 11.200 1 11/16
8 1 1 27.900 2 1/4
A
A C x C
WROT CAST
106 45° Elbow
Copper to Copper
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
3/8 25 500 0.033 1 3/16
1/2 25 250 0.056 1 7/16
3/4 25 250 0.12 2
1 10 100 0.224 2 15/32
1 1/4 5 50 0.388 2 29/32
1 1/2 5 50 0.560 3 5/16
2 5 40 1.156 4 3/8
A
A
FTG. x FTG.
WROT CAST
105-L90°Street Elbow-Long Turn
Fitting to Fitting
WROT CAST
101 Coupling Without Stop
Copper to Copper
Wrot & Cast Pressure Fittings
Couplings
4 Elkhart Products Corporation Asubsidiary of Amcast Industrial Corporation ** Cast Bronze Only *Factory Optionconsult factory for price and delivery information.
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
1/4OD x 3/16 OD 50 1000 0.004 3/32
3/8OD x 5/16 OD 50 1000 0.008 3/32
1/4 x 1/8 50 1000 0.008 5/32
3/8 x 1/4 50 1000 0.017 3/16
3/8 x 1/8 50 1000 0.019 1/4
1/2 x 3/8 50 1000 0.026 5/32
1/2 x 1/4 50 1000 0.024 1/4
1/2 x 1/8 50 1000 0.025 23/64
5/8 x 1/2 25 500 0.035 5/32
5/8 x 3/8 25 500 0.036 7/32
5/8 x 1/4 25 500 0.043 5/16
3/4 x 5/8 50 500 0.066 3/16
3/4 x 1/2 50 500 0.061 3/16
3/4 x 3/8 50 500 0.052 21/64
3/4 x 1/4 50 500 0.053 7/16
1 x 3/4 25 250 0.098 13/32
1 x 5/8 25 250 0.102 3/8
1 x 1/2 25 250 0.104 7/16
1 x 3/8 25 250 0.093 1/2
1 1/4 x 1 10 100 0.152 5/16
1 1/4 x 3/4 10 100 0.134 15/32
1 1/4 x 1/2 10 100 0.165 41/64
1 1/2 x 1 1/4 10 100 0.220 11/32
1 1/2 x 1 10 100 0.220 7/16
1 1/2 x 3/4 10 100 0.218 21/32
1 1/2 x 1/2 10 100 0.219 25/32
2 x 1 1/2 10 100 0.366 13/32
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
2 1/2 5 50 0.616 3 1/32
3 5 40 0.912 3 13/32
3 1/2 1 16 1.352 3 29/32
4 2 16 1.878 4 13/32
5 1 6 3.365 5 1/2
6 1 6 5.262 6 3/8
8 1 1 12.941 8 1/4Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
3/16 OD 50 1000 0.002 1/16
5/16 OD 50 1000 0.006 1/16
1/8 50 1000 0.004 1/16
1/4 50 1000 0.007 3/32
3/8 50 1000 0.014 3/32
1/2 100 1000 0.021 3/32
5/8 25 500 0.040 3/32
3/4 50 500 0.048 3/32
7/8 10 200 0.084 3/32
1 25 250 0.088 3/32
1 1/4 20 200 0.144 3/32
1 1/2 10 100 0.216 3/32
2 5 50 0.391 3/32
2 1/2 5 50 0.624 3/32
3 5 40 0.909 3/32
3 1/2 1 16 1.369 3/32
4 2 16 1.904 3/32
5 1 6 3.365 3/16
6 1 6 5.262 3/16
8 1 1 12.941 1/8
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
1/4 50 1000 0.006 23/32
3/8 50 1000 0.013 55/64
1/2 100 1000 0.019 1 3/32
3/4 50 500 0.046 1 19/32
1 25 250 0.087 1 29/32
1 1/4 20 200 0.149 2 1/32
1 1/2 10 100 0.213 2 17/64
2 5 50 0.391 2 49/64
A
A
WROT CAST
101 Coupling Without Stop-cont.
Copper to Copper
WROT CAST
101-R Coupling With Stop 4701-R
Copper to Copper
A
C x C
C x C
C x C
WROT CAST
100 Coupling With Stop
Copper to Copper
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
1/8 50 1000 0.0187 13/32
1/4 50 1000 0.027 15/32
3/8 50 500 0.041 7/8
1/2 50 500 0.064 19/32
3/4 25 250 0.119 13/16
1 20 200 0.160 27/32
1 1/4 10 100 0.317 15/16
1 1/2 10 100 0.443 7/8
2 5 50 0.675 1 11/32
2 1/2 4 40 1.267 1 21/32
3 2 20 2.138 1 25/32
4 1 16 3.500 1 29/32
**5 5 5 8.600 -
**6 4 4 10.730 -
1/8 x 3/8 50 1000 0.040 3/4
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
1/4 50 1000 0.030 29/32
3/8 50 1000 0.049 1 1/16
1/2 50 500 0.084 1 3/8
3/4 25 250 0.143 1 11/16
1 20 200 0.214 1 31/32
1 1/4 10 100 0.324 2 5/32
1 1/2 10 100 0.437 2 7/16
2 5 50 0.641 2 19/32
**2 1/2 25 25 1.740 -
**3 20 20 2.470 -
1/2 x 3/8 50 500 0.062 1 1/8
1/2 x 1/4 50 500 0.041 59/64
**3/4 x 1/2 25 225 0.147 -
**1 x 3/4 25 250 0.414 -
**1 x 1/2 25 250 0.153 -
A
6 Elkhart Products Corporation Asubsidiary of Amcast Industrial Corporation ** Cast Bronze Only *Factory Optionconsult factory for price and delivery information.
Nominal Size Box Master Approx. Dim.
In Inches Quantity Pack Net Wt. A
1/8 50 1000 0.029 7/16
1/4 50 1000 0.031 15/32
3/8 50 500 0.053 19/32
1/2 50 500 0.086 7/8
3/4 25 250 0.143 23/32
1 20 200 0.226 31/32
1 1/4 10 100 0.304 1 3/32
1 1/2 10 100 0.404 1 5/32
2 5 50 0.650 1 1/4
2 1/2 2 20 1.228 1 1/2
**3 12 12 2.400 -
**4 12 12 3.820 -
**5 6 6 8.250 -
**6 4 4 12.000 -
1/8 x 1/4 50 1000 0.033 1/2
1/4 x 1/2 50 500 0.078 25/32
1/4 x 3/8 50 1000 0.043 21/32
1/4 x 1/8 50 1000 0.024 11/32
3/8 x 1/2 50 500 0.082 7/8
3/8 x 1/4 50 1000 0.041 15/32
**1/2 x 1 25 150 0.300 -
1/2 x 3/4 25 250 0.121 29/32
1/2 x 3/8 50 500 0.046 9/16
1/2 x 1/4 50 500 0.044 15/32
5/8 x 3/4 25 250 0.143 1
5/8 x 1/2 25 250 0.102 3/4
**3/4 x 1 1/4 10 100 0.515 -
3/4 x 1 20 200 0.218 1 7/32
3/4 x 1/2 25 250 0.085 19/32
**1 x 1 1/2 10 100 0.720 -
1 x 1 1/4 10 100 0.299 1 7/32
1 x 3/4 25 250 0.159 43/64
1 x 1/2 10 100 0.239 11/16
**1 1/4 x 2 5 50 0.980 -
1 1/4 x 1 1/2 10 100 0.431 1 19/64
1 1/4 x 1 10 100 0.238 55/64
**1 1/4 x 3/4 100 100 0.290 -
1 1/2 x 2 5 50 0.678 1 7/16
1 1/2 x 1 1/4 10 100 0.388 7/8
**1 1/2 x 1 60 60 0.370 -
2 x 1 1/2 5 50 0.730 1 3/16
A
A
C x F
C x M
FTG. x F
WROT CAST
103 Female Adapter 4703
Copper to Female N.P.T.
WROT CAST
103-2 Female Street Adapter 4703-2
Fitting to Female N.P.T.
WROT CAST
104 Male Adapter 4704
Copper to Male N.P.T.
Wrot & Cast Pressure Fittings
Adapters
Page 1 of1Print
11/2/2011http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1962
Hilti Product Technical Guide 2001 Hilti U.S.: 1-800-879-8000 / www.us.hilti.com Hilti Canada: 1-800-363-4458 / www.ca.hilti.com134
Anchoring Systems
4.3.5HDI / HDI-L Drop-In Anchor
Anchor Size in. 1/ 4 3 /8 1 /2 5 /8 3/4
Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1)
d bit: bit diameter1 in. 3 /8 1 /2 5 /8 27/32 1
h nom: std.depth of embed. in. 1 19/16 2 2 9 /16 3 3/16
: anchor length (mm) (25) (40) (51) (65) (81)
h1: hole depth
th: useable thread in. 7/ 16 5/8 11 /16 7/8 1 3/8
length (mm) (11) (15) (17) (22) (34)
Threads per in. 20 16 13 11 10
h: min.base material in. 3 31/ 8 4 5 1 /8 6 3/8
thickness (mm) (76) (79) (102) (130) (162)
Tinst: max. tightening ft lb 4 11 22 37 80
torque (Nm) (5.4) (14.9) (29.8) (50.2) (108.5)
4.3.4.1 PRODUCT DESCRIPTION
The Hilti HDI/HDI-L Drop-In anchor is an internally threaded,
flush mounted expansion anchor for use in concrete.
Product Features
Guide Specifications
Expansion Anchors: Expansion anchors shall be flush or shell type which meet the description in Federal Specification FF-S-325,
Group VIII, Type 1, for expansion shield anchors. Anchors to be zinc plated in accordance with ASTM B633,
Sc. 1, Type III. Anchors shall be Hilti HDI/HDI-L anchors as supplied by Hilti, Inc., P.O. Box 21148, Tulsa, OK
74121.
Installation: Shell or flush type anchors to be installed in holes drilled with Hilti carbide tipped drill bits. Anchors shall be
installed per manufacturers recommendations.
Approvals/Listings
City of Los Angeles (COLA): Research Report No. 23709 (HDI Only)
Factory Mutual (FM): Serial No. 22765 Sprinkler Hangar ComponentsExpansion Shields. (HDI and HDI-L)
Conforms to the description in Federal Specification FF-S-325, Group VIII, Type 1 for expansion shield anchors. (HDI and HDI-L)
Underwriters Laboratory (UL), Pipe Hangers (3/8"3/4" diameter) (HDI and HDI-L)
International Conference of Building Officials (ICBO ES): Evaluation Report No. 2895 (HDI Only)
Southern Building Code Congress (SBCCI): Report No. 9930 (HDI Only)
4.3.5.2 MATERIAL SPECIFICATIONS
HDI/HDI-LCarbon Steel material meets the requirements of AISI 1010M for the 1/4", 3/8" & 1/2
HDI Carbon Steel material meets the requirements of AISI 12L14 for the 5/8 and 3/4 sizes
HDIStainless Steel material meets the requirements of AISI303
Carbon Steel HDI/HDI-L plated with a dull zinc finish for corrosion protection in accordance with
ASTM B633, Sc. 1, Type III
4.3.5.3 TECHNICAL DATA
HDI/HDI-LSpecification Table
Combined Shear and
Tension Loading
(Ref. Section 4.1.3)
≤ 10
44 (303) 53 (365)
60 (415) 78 (540)
60 (414) 100 (689)
MECHANICALPROPERTIES
fy min. fuksi (MPa) ksi (MPa)
HDI/HDI-L HDI/HDI-L HDI/HDI-L HDI HDI
HDI
Anchor, setting tool & Hilti drill bit
form a matched tolerance
system to provide reliable
fastenings
Below surface setting for easy
patchwork
Allows for shallow embedment
without sacrificing performance
HDI-L
Lip provides flush installation,
consistent anchor depth, and
easy rod alignment
Lip allows accurate flush surface
setting, independent of hole
depth & ideal for repetitive
fastenings with threaded rods
of equal length
Intelligent expansion section
adapts to the base material &
reduces number of hammer
blows up to 50%
Easy to read brand & size
identification (red laser print)
1.For Hilti matched tolerance carbide tipped drill bits, see section 10.4.1.
5/10/2001-71-
ToL c 0
INCORPORATED
CORONA, CA (909)737-5599
Fig. 65 and Fig. 66
Reversible C-Type Beam Clamps
3/4 and 1-1/4 Inch Throat Openings
Size Range (Fig. 65 and Fig. 66) 3/8, 1/2, AND 5/8 inch rod.
Material CarbonSteel withhardenedcuppointsetscrew andjamnut.
Function Recommended for hanging from steel beam where flange
thickness does not exceed 3/4 inch (Fig. 65) or 1-1/4" (Fig. 66)
Features All steel construction eliminates structural deficiencies
associated with casting type beam clamps. May be used on top or
bottom flange of the beam. (Beveled lip allows hanging from top flange
where clearance is limited.) May be installed with set screw in up or
down position. Offset design permits unlimited rod adjustment by
allowing the rod to be threaded completely through the clamp. Open
design permits inspection of thread engagement.
Approvals Underwriters' Laboratories Listed in the USA (UL) and
Canada (cUL). Factory Mutual Engineering Approved. Conforms to
Federal Specification Society SP-69, type 19 and 23. Exceeds
requirements of the National Fire Protection Association (NFPA),
Pamphlet #13, 3/8 inch rod will support 1/2 thru 4 inch pipe, 1/2 inch rod
will support 1/2 thru 8 inch pipe.
Finish Plain.
Note—Available in Electro-Galvanized and HDG finish.
Order By—Figure number, rod size, and finish.
Fig. 65 Patent #4,570,885
F I G . 6 5 T A B L E
ROD MAX. REC. APPROXB C D E FSIZEA LOAD LBS.* WT./100
3/8 1-3/16 3/4 1 7/16 1 610 28
1/2 1-1/2 3/4 1 9/16 1-1/4 1130 55
5/8 1 -1/2 3/4 1 9/16 1 -1/4 1130 55
*Max. loads forclamp with set screw in up ordown position.
FIG. 66 TABLE
ROD MAX. REC. APPROXB C D E FSIZEA LOAD LBS.* WT./100
3/8 1-3/16 1-1/4 1 7/16 1 610 28
1/2 1-1/2 1-1/4 1 9/16 1-1/4 1130 55
5/8 1-1/2 1-1/4 1 9/16 1-1/4 1130 55
*Max. loads for clamp with set screw in up or down position.
5/10/2001-82-
ToLc0
INCORPORATED
CORONA, CA (909)737-5599
Fig. 98
Rod Stiffener
Size Range—Secures 3/8 thru 7/8 inch hanger rod.
Material – Carbon Steel.
Function—Secures channel to hanger rod for vertical
seismicbracing.
Finish—Electro Galvanized.
Order By—Figure number.
Note—AvailableinHDGfinishor StainlessSteel
materials.
Fig. 99
All Thread Rod Cut To Length
Fig. 100
All Thread Rod Full Lengths
ROD
SIZE
MAX.REC.LOADLBS.
FORSERVICETEMPS
650°F 750°F
APPROX.
WEIGHT
PER100FT.
1/4 240 215 12
3/8 610 540 29
1/2 1130 1010 53
5/8 1810 1610 84
3/4 2710 2420 123
7/8 3770 3360 169
1 4960 4420 222
1-1/4 8000 7140 360
1-1/2 11630 10370 510
Size Range-3/8 thru 7/8 inch rod in 1
inch increments.
Material – Carbon Steel.
Maximum Temperature-750°F.
Finish— Plain.
Order By—Figure number, rod
diameter, rod length, and finish.
Note—AvailableinElectro-Galvanized
and HDG finish or Stainless Steel
materials.
ROD
SIZE
MAX.REC.LOADLBS.
FORSERVICETEMPS
650°F 750°F
3/8 610 540
1/2 1130 1010
5/8 1810 1610
3/4 2710 2420
7/8 3770 3360
Size Range-3/8 thru 7/8 inch rod
in 10 foot lengths.
Material – Carbon Steel.
Maximum Temperature-750°F.
Finish— Plain.
Order By—Figure number, rod
diameter, and finish. Note—
Available in Electro-
Galvanized and HDG finish or
Stainless Steel materials.
5/10/2001-103-
To'. c 0
INCORPORATED
CORONA, CA (909)737-5599
Fig. 200
®c®"Trimline" Adjustable Band Hanger
Size Range — 1/2 thru 8 inch pipe.
Material — CarbonSteel, Mil. GalvanizedtoG-90
specifications.
Function — For fire sprinkler and other general piping
purposes. Knurled swivel nut design permits hanger
adjustment after installation.
Features
(1/2 thru2 inch) Flared edges ease installationfor all
pipe types and protect CPVC plastic pipe from
abrasion. Captured design keeps adjusting nut from
separating with hanger. Hanger is easily installed
around pipe.
(2-1/2 thru 8 inch) Spring tension on nut holds it
securelyinhanger beforeinstallation. Adjustingnutis
easilyremoved.
Approvals— Underwriters' Laboratories Listed (1/2"
thru 8") in the U.S. (UL) and Canada (cUL) for steel
and CPVC plastic pipe and Factory Mutual
Engineering Approved (3/4" thru 8"). Conforms to
Federal Specifications WW-H-171 E, Type 10, and
Manufacturers StandardizationSocietySP-69, type 10.
Maximum Temperature - 650°F.
Finish — Mil. Galvanized, for Stainless Steel materials
order Tolco Fig. 200WON.
Order By— Figure number and pipe size.
1/2THRU2INCH PIPE 2 1/2 THRU 8 INCH PIPE
PIPE
SIZE INCH
ROD SIZE
METRIC* A B MAX. REC.
LOAD LBS.
APPROX.
WT./100
1/2 3/8 8mm or 10mm 3-1/8 2-5/8 400 11
3/4 3/8 8mm or 10mm 3-1/8 2-1/2 400 11
1 3/8 8mm or 10mm 3-3/8 2-5/8 400 12
1-1/4 3/8 8mm or 10mm 3-3/4 2-7/8 400 13
1-1/2 3/8 8mm or 10mm 3-7/8 2-7/8 400 14
2 3/8 8mm or 10mm 4-1/2 3 400 15
2-1/2 3/8 10mm 5-5/8 4-1/8 600 27
3 3/8 10mm 5-7/8 4 600 29
3-1/2 3/8 10mm 7-3/8 5-1/4 600 34
4 3/8 10mm 7-3/8 5 1000 35
5 1/2 12mm 9-1/8 6-1/4 1250 66
6 1/2 12mm 10-1/8 6-3/4 1250 73
8 1/2 12mm 13-1/8 8-3/4 1250 136
*Order Fig. 200M