Loading...
HomeMy WebLinkAboutF18-0017_Approved Documents_1524497552.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Fire - Construction Permit F18-0017 Issued: 04/23/2018 TOWN OF VAIL Property Information Address: 660 LIONSHEAD PL ( 210107203999 ) Unit #: Parcel Number: 210107203999 Legal Description: Contacts Contact Type: Applicant Full Name: Jeremy Craig Address: 10864 Wets CoCo Place Littleton, CO 80127 Phone: 9703933242 Contact Type: Property Owner Full Name: Common Area Address: Phone: None Contractor Contractor Type: Fire Protection Company: Assurance Fire Systems, Inc. State License #: 18-S-06113 Phone: 303-798-4448 Project Information Project Name: Lion Square Lodge South 2018 Project Description: Relocate Fire sprinklers in conference room for new ceiling designs Fees Paid Account #: 001-0000.31111.00 - Fire Suppression Permit Fee Fee Amount: $327.25 Account #: 001-0000.21123.00 - Fire Suppression Review Fee Fee Amount: $432.00 Total Paid: $759.25 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # F18-0017 Date Printed: 04/17/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0017 Status: Created Permit Number: Date Started: 04/13/2018 Permit Type: Fire - Construction Permit Subcases Fire Suppression Lot Number: 1 Property: 660 LIONSHEAD PL (210107203999) Contacts Contact Type: Applicant Company Name: Assurance Fire Systems Full Name: Jeremy Craig Address: 10864 Wets CoCo Place Littleton, CO 80127 Email: jcraig@assurancefiresystems.com Contact Type: Property Owner Full Name: Common Area Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $327.25 Fire Suppression Review Fee 001-0000.21123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Review Fee 04/17/2018 Credit Card $432.00 Paid By: - Notes: Visa - Jeremy Craig Fire Suppression Permit Fee 04/17/2018 Credit Card $327.25 Paid By: - Notes: Visa - Jeremy Craig FEE TOTAL $759.25 AMOUNT PAID $759.25 BALANCE DUE $0.00 04/17/2018 - 10:37:36 AM - Generated by: dcouch75 South Frontage Road West, Vail, Colorado 81657 1 / 1 10864 WEST COCO PLACE LITTLETON, CO 80127 Tel: (303) 798-4448 Fax: (720) 922-7698 Chris@AssuranceFireSystems.com FIRE SPRINKLER PRODUCT SUMITTALS FOR Hyatt Place at Depot Square 3151 Pearl Street Boulder, CO LIONSSQUARE LODGE 660 W. LIONSHEAD PLACE VAIL,CO microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers tecHnical data June 28, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com 1. descriPtion Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design require- ments. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: fm global approves the ent coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. listings and aPProvals culus listed: Category VNIV fm approved: Classes 2002 and 2020 nYc approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 aBs certified: Certificate 04-HS407984B-PDA vds approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 lPc approved: Ref. No. 096e/03, TE30401, and TE30872 ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 med certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 note: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. tecHnical data specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* maximum Working Pressure: sprinklers vk315 and vk340 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the de- flector. all other Part nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). material standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper UNS-C19500 for Sprinklers 06665B, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Form No. F_080488 viking technical data may be found on the viking corporation’s Web site at http://www.vikinggroupinc.com. the Web site may include a more recent edition of this technical data Page. Sprinkler 51a Replaces page 51a-e, dated June 11, 2013. (ENT finish is no approved as corrosion resistant.) tecHnical data June 28, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. ordering information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N, ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2” thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB available finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) sprinkler cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. oPeration During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. insPections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availaBilitY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. guarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 51b taBle 1: availaBle sPrinkler temPerature ratings and finisHes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 Bulb color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue sprinkler finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT corrosion-resistant coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers tecHnical data June 28, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com approval chart 1 (ul) microfast® and microfastHP® quick response upright and conventional sprinklers maximum 175 Psi (12 bar) WWP Base Part number1 sin thread size nominal k-factor overall length listings and approvals3 (refer also to design criteria on page 51d.) nPt BsP u.s. metric2 inches mm culus4 nYc8 vds lPcB upright-standard orifice 12978 VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A1, B4 See Footnote 7. -- -- -- -- 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 -- -- A2 A2 B212 B215 conventional-standard orifice 06766B VK310 1/2” 15 mm 5.6 80.6 2-3/16 56 A2 A2 -- A2 B212 B215 upright-large orifice 06665B VK350 3/4” -- 8.0 115.2 2-5/16 59 A1, B4 A1 A2 A2 B212 -- 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A1, B4 A1 A2 A2 B212 -- 06764B16 VK350 1/2” 15 mm 8.0 115.2 2-5/16 59 A1, B4 A1 A2 -- A213 -- conventional-large orifice 06768B VK354 3/4” 20 mm 8.0 115.2 2-5/16 59 A1 A2 -- A2 B212 -- upright-small orifice11 06717B11 VK325 1/2” 15 mm 2.8 40.3 2-3/16 56 A1 A1 -- -- -- -- 06719B11 VK327 1/2” 15 mm 4.2 57 2-3/16 56 A1 A1 -- -- -- -- 06931B11 VK327 -- 10 mm 4.2 57 2-3/16 56 -- -- A2 -- C314 -- maximum 250 Psi (17 bar) WWP upright-standard orifice Base Part number1 sin thread size nominal k-factor overall length listings and approvals3 (refer also to design criteria on page 51d.) nPt BsP u.s. metric2 inches mm culus4 nYc9 vds lPcB 12281 VK315 1/2” 15 mm 5.6 80.6 2-3/16 56 A1 A1 -- -- -- -- upright-small orifice10 1228611 VK340 1/2” 15 mm 2.8 40.3 2-3/16 56 A1 A1 -- -- -- -- approved temperature ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) C - 155 °F (68 °C) approved finishes 1 - Brass, Chrome, White Polyester5,6, Black Polyester5,6, and Black PTFE5 2 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6 3 - Brass and Chrome 4 - ENT5 footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Meets New York City requirements, effective July 1, 2008. 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 11The sprinkler orifice is bushed. 12 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278. 14 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 16 The 1/2” NPT Large Orifice Sprinkler is Listed and Approved for retrofit only Sprinkler 51c tecHnical data June 28, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers Sprinkler 51d figure 1: standard sprinkler Wrench 10896W/B design criteria - ul (Also refer to Approval Chart 1 on page 51c) culus listing requirements: Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. • • imPortant: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in accor- dance with the latest edition of viking technical data, the appropriate standards of nfPa, lPcB, aPsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers tecHnical data June 28, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Sprinkler 51e design criteria - fm (Also refer to Approval Chart 2 above.) fm approval requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response non-storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. note: the fm installation guidelines may differ from culus and/or nfPa criteria. imPortant: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac- cordance with the latest edition of viking technical data, the appropriate standards of nfPa, fm global, lPcB, aPsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. approval chart 2 (fm) microfast® quick response upright sprinklers maximum 175 Psi (12 bar) WWP Base Part number1 sin thread size nominal k-factor overall length fm approvals3 (refer also to design criteria below.)nPt BsP u.s. metric2 inches mm standard orifice 12978 VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A2, B3 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2 large orifice 06665B VK350 3/4” -- 8.0 115.2 2-5/16 59 A2, B3 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2, B3 06764B7 VK350 1/2” 15 mm 8.0 115.2 2-5/16 59 A2, B3 small orifice4 06717B6 VK325 1/2” 15 mm 2.8 40.3 2-3/16 56 A1 approved temperature ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) approved finishes 1 - Brass and Chrome 2 - Brass, Chrome, White Polyester5, and Black Polyester5 3 - ENT8 footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 FM Approved as quick response non-storage pendent sprinklers. For specific application and installation requirements, reference the latest appli- cable FM Loss Prevention Data Sheets (including Data Sheet 2-0). 5 Other colors are available on request with the same Approvals as the standard colors. 6 The sprinkler orifice is bushed. 7 The 1/2” NPT Large Orifice Sprinkler is Listed and Approved for retrofit only 8 FM approved as corrosion resistant. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data Form No. F_103005 16.07.28 Rev 16.1 Page 1 of 6 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page. 1. description Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. listings and approvals cUlus listed: Category VNIV Fm approval: Class 2015 nYc approved: MEA 89-92-E, Volume 32 vds approved: Certificate G4080021 lpcB approved: Ref. No. 096e/12 ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 cccF approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. technical data Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* maximum Working pressure: sprinkler vk463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. high-pressure (hp) sprinklers can be identified by locating “250” stamped on the deflector. sprinkler vk462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric†) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). †Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. material standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Replaces Form No. F_103005 Rev 15.1 (Added PNs for CCCF Approved sprinklers; upgraded graphics) mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data Form No. F_103005 16.07.28 Rev 16.1 Page 2 of 6 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page. cover assembly materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic ordering information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB. cover plate assembly: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16“ diameter), or Base Part No. 15394 (square cover plate, 3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F (57 °C) UL (139 °F (59 °C) FM and LPCB) = A, 165 °F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. available Finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the Viking website.) sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. sprinkler cabinet: Part No. 01731A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availaBilitY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. gUarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data Form No. F_103005 16.07.28 Rev 16.1 Page 3 of 6 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page. approval chart 1 (Ul) mirage® concealed pendent sprinklers vk462 and vk463 sprinkler Base part no.1 sin npt thread size nominal k-Factor maximum Water Working pressure listings and approvals4 (refer also to design criteria) inch mm U.s. metric2 cUlus5 nYc vds7 lpcB standard response applications 13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) -- -- AY1, CZ1 AY1, BZ1 AY1, CZ18 -- 19785A VK462 1/2” -- 5.6 80.6 175 psi (12 bar) -- -- -- -- -- AY2, CZ2 Quick response applications 13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 -- -- -- -- 13503JN11 VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW16 -- -- -- -- 13667A VK463 1/2” 15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 AV1, BW16 -- -- -- -- sprinkler temperature ratings A - 155 °F (68 °C) B - 175 °F (79 °C) and 200 °F (93 °C) C - 200 °F (93 °C) cover plate assembly temperature ratings9 V - 135 °F (57 °C) cULus Listed cover 135041, 136421 (large diam- eter), or 153941 (square cover plate) W - 165 °F (74 °C) cover 135041 or 136421 (large diameter) X - 165 °F (74 °C) cover 135041, or 136421 (large diameter) Y - 135 °F (57 °C) cover 135041 LPCB Approved as 139 °F (59 °C) Z - 165 °F (74 °C) cover 135041 cover plate assembly Finishes10 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 - Brass Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional ap-provals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7 VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021.8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032.9 The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approv-als apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. note: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. taBle 1: availaBle sprinkler temperatUre ratings and Finishes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 temperature rating of cover assembly (required)Bulb color Ordinary 155 °F (68° C) 100 °F (38 °C)135 °F (57 °C) cULus 139 °F (59 °C) FM and LPCB Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green cover plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black sprinkler Finishes: Brass and ENT corrosion resistant coatings3: ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data Form No. F_103005 16.07.28 Rev 16.1 Page 4 of 6 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page. design criteria - Ul (Also refer to Approval Chart 1) cUlus listing requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition ofNFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measuredperpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. note: concealed sprinklers must be installed in neutral or negative pressure plenums only. vds approval requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan-cies, except in OH4. notes: Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to Bulletin Form no. F_080614 for general care, installation, and maintenance information. viking sprinklers are to be in- stalled in accordance with the latest edition of viking technical data, the appropriate standards of nFpa, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 1: identification of custom paint for concealed covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label.FACTORY APP L IE D CUSTO M PAI NT COLORFigure 2: square cover assembly 15394 3-5/16” (84 mm) mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data Form No. F_103005 16.07.28 Rev 16.1 Page 5 of 6 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page. design criteria - Fm (Also refer to Approval Chart 2 above.) Fm approval requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response non-storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. note: the Fm installation guidelines may differ from cUlus and/or nFpa criteria. important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to page sr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac- cordance with the latest edition of viking technical data, the appropriate standards of nFpa, Fm global, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. approval chart 2 (Fm) mirage® standard response concealed pendent sprinkler vk462 sprinkler Base part no.1 sin npt thread size nominal k-Factor maximum Water Working pressure Fm approvals3 (refer also to design criteria below.)inch mm U.s. metric 2 13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AW1, BX1 sprinkler temperature ratings A - 155 °F (68 °C) B - 175 °F (79 °C) and 200 °F (93 °C) cover plate assembly temperature ratings4 W - 139 °F (59 °C) cover 135041, 136421 (large diameter), or 153941 (square cover plate) X - 165 °F (74 °C) cover 135041, 136421 (large diameter), or 153941 (square cover plate) cover plate assembly Finishes5 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. note: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data Form No. F_103005 16.07.28 Rev 16.1 Page 6 of 6 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com visit the viking website for the latest edition of this technical data page. sprinkler and adapter assembly • protective cap removed • Use wrench 14047W/B** step 1: carefully slide the wrench sideways around the deflector and pins sprinkler Wrench part no. 14047W/B** ** a 1/2” ratchet is required (not available from viking) 2-1/4” (57 mm) diameter opening required in the ceiling. step 2: carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 3: sprinkler installation and proper Wrench Usage never install the sprinkler by applying the installation wrench across the frame arms. do not overtighten. Use only the designated sprinkler wrenches, viking part numbers 14047W/B** or 14031**. a leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. sprinkler wrench flat sprinkler frame arms Figure 4: sprinkler dimensions and cover installation 1/2” (15 mm) npt 2-3/16”(55 mm)2-9/16” (65 mm) maximum 2-1/16” (52 mm) minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)note: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Replaces Form No. F_103005 Rev 15.1 (Added PNs for CCCF Approved sprinklers; upgraded graphics) Eddy Flow A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: info@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 3/01 The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems in commercial and residential construction, Bull Moose Tube has added Eddy Flow to its comprehensive line of sprinkler pipe products. Eddy Flow is a specially engineered replacement for schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding. Please check with appropriate sources for up-to-date listings and approval information. As an added benefit, it is more economical to use than schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow’s larger ID provides an opportunity for downsizing and further cost savings. COMPARISON Inside Diameter C.R.R.* NPS (in) O.D. (in) Eddy Flow (in) Sch. 10 (in) Sch. 40 (in) Eddy Flow Schedule 40 1-1/2 2 2-1/2 3 4 1.900 2.375 2.875 3.500 4.500 1.754 2.229 2.729 3.342 4.316 1.682 2.157 2.635 3.260 4.260 1.610 2.067 2.469 3.068 4.026 2.34 1.89 1.09 1.00 1.00 1.00 1.00 1.00 1.00 1.00 * Corrosion Resistance Ratio BENEFITS · Dual Certified to ASTM A135 and A795. · FM approved for roll grooving and welding for use in wet systems. · UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. · Lightweight - saves shipping costs, and offers easier handling. · Can be used with roll grooved couplings or welded outlets for pressures up to 175 psi. · Floor stock available in various lengths produced in Trenton (GA), Gerald (MO), and Masury (OH). Also can be ordered in custom lengths. · Can be supplied roll grooved or plain end. · Can be used for wet and dry* systems. * Eddy Flow can be hot dipped galvanized to meet FM’s requirement for dry systems. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. S3 - 2 DYNA THREAD ® With ABF Protection With ABF Protection ContentsNext Previous Return S3 - 3 Comparison to L.W.T. PipesComparison to Schedule 40 Specifications & Approvals Dyna-Thread ® Full Line Sch-40 Replacement Dyna-Thread® offers the life expectancy of Sch-40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. · Dyna-Thread’s inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. · Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. · The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. · The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. · The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. · More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. · Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. · Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. · Dyna-Thread is safer to weld on. · Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be “hot-dip” galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. Wt. (H2O Filled)Pcs/Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 11®4" 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11®2" 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2" 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 · With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000” in diameter is coated with our new Antibacterial Formula, “ABF”. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. FM Listed Approved Listed 16100 S. Lathrop · Harvey, IL 60426 11350 Norcom Rd. · Philadelphia, PA 19154 2525 N. 27 th Ave. · Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 ContentsNext Previous Return THE COPPER TUBE HANDBOOK CDA Copper Development Association Nominal or Standard Size, inches Outside Diameter Inside Diameter Cu ft Gal Wall Thickness Contents of Tube per linear ft Cross Sectional Area of Bore, sq inches Weight of Tube Only, pounds per linear ft Weight of Tube & Water, poundsper linear ft Nominal Dimensions, inches Calculated Values (based on nominal dimensions) 3/8 .500 .450 .025 .159 .145 .214 .00110 .00826 1/2 .625 .569 .028 .254 .204 .314 .00176 .0132 3/4 .875 .811 .032 .517 .328 .551 .00359 .0269 1 1.125 1.055 .035 .874 .465 .843 .00607 .0454 11/4 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681 11/2 1.625 1.527 .049 1.83 .940 1.73 .0127 .0951 2 2.125 2.009 .058 3.17 1.46 2.83 .0220 .165 21/2 2.625 2.495 .065 4.89 2.03 4.14 .0340 .254 3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363 31/2 3.625 3.459 .083 9.40 3.58 7.64 .0653 .488 4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634 5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982 6 6.125 5.881 .122 27.2 8.92 20.7 .189 1.41 8 8.125 7.785 .170 47.6 16.5 37.1 .331 2.47 10 10.125 9.701 .212 73.9 25.6 57.5 .513 3.84 12 12.125 11.617 .254 106 36.7 82.5 .736 5.51 Nominal or Standard Size, inches Outside Diameter Inside Diameter Cu ft Gal Wall Thickness Contents of Tube per linear ft Cross Sectional Area of Bore, sq inches Weight of Tube Only, pounds per linear ft Weight of Tube & Water, pounds per linear ft Nominal Dimensions, inches Calculated Values (based on nominal dimensions) 11/4 1.375 1.295 .040 1.32 .650 1.22 .00917 .0686 11/2 1.625 1.541 .042 1.87 .809 1.62 .0130 .0971 2 2.125 2.041 .042 3.27 1.07 2.48 .0227 .170 3 3.125 3.030 .045 7.21 1.69 4.81 .0501 .375 4 4.125 4.009 .058 11.6 2.87 7.88 .0806 .603 5 5.125 4.981 .072 19.5 4.43 12.9 .135 1.01 6 6.125 5.959 .083 27.9 6.10 18.2 .194 1.45 8 8.125 7.907 .109 49.1 10.6 31.8 .341 2.55 22 TABLE 2c. Dimensions and Physical Characteristics of Copper Tube: TYPE M TABLE 2d. Dimensions and Physical Characteristics of Copper Tube: DMV (Drain, Waste and Vent) 26 TABLE 3c. Rated Internal Working Pressure for Copper Tube:TYPEM* TABLE 3d. Rated Internal Working Pressure for Copper Tube: DWV* NOTE: *Based on maximum allowable stress in tension (psi) for the indicated temperatures (°F), see page 12. **When brazing or welding is used to join drawn tube, the corresponding annealed rating must be used, see page 12. ***Types M and DWV are not normally available in the annealed temper. Shaded values are provided for guidance when drawn temper tube is brazed or welded, see page 12. Nominal Size, in S= 6000 psi 100 F S= 5100 psi 150 F S= 4900 psi 200 F S= 4800 psi 250 F S= 4700 psi 300 F S= 4000 psi 350 F Annealed*** Drawn** 1/4 — — — — — — — — — — — — — — 3/8 570 485 466 456 447 380 285 982 982 982 982 953 925 896 1/2 494 420 403 395 387 329 247 850 850 850 850 825 800 776 5/8 — — — — — — — — — — — — — — 3/4 407 346 332 326 319 271 204 701 701 701 701 680 660 639 1 337 286 275 270 264 225 169 580 580 580 580 563 546 529 11/4 338 287 276 271 265 225 169 582 582 582 582 565 548 531 11/2 331 282 270 265 259 221 166 569 569 569 569 553 536 520 2 299 254 244 239 234 199 149 514 514 514 514 499 484 469 S= 3000 psi 400 F S= 10,300 psi 100 F S= 10,300 psi 150 F S= 10,300 psi 200 F S= 10,300 psi 250 F S= 10,000 psi 300 F S= 9,700 psi 350 F S= 9,400 psi 400 F 21/2 274 233 224 219 215 183 137 471 471 471 471 457 444 430 3 253 215 207 203 199 169 127 435 435 435 435 423 410 397 31/2 252 214 206 202 197 168 126 433 433 433 433 421 408 395 4 251 213 205 201 197 167 126 431 431 431 431 419 406 394 5 233 198 190 186 182 155 116 400 400 400 400 388 377 365 6 218 186 178 175 171 146 109 375 375 375 375 364 353 342 8 229 195 187 183 180 153 115 394 394 394 394 382 371 359 10 230 195 188 184 180 153 115 394 394 394 394 383 371 360 12 230 195 188 184 180 153 115 395 395 395 395 383 372 360 NominalSize, in S= 6000 psi 100 F S= 5100 psi 150 F S= 4900 psi 200 F S= 4800 psi 250 F S= 4700 psi 300 F S= 4000 psi 350 F Annealed*** Drawn** 11/4 330 280 269 264 258 220 165 566 566 566 566 549 533 516 11/2 293 249 240 235 230 196 147 503 503 503 503 489 474 459 2 217 185 178 174 170 145 109 373 373 373 373 362 352 341 3 159 135 130 127 125 106 80 273 273 273 273 265 257 249 4 150 127 122 120 117 100 75 257 257 257 257 250 242 235 5 151 129 124 121 119 101 76 260 260 260 260 252 245 237 6 148 126 121 119 116 99 74 255 255 255 255 247 240 232 8 146 124 119 117 114 97 73 251 251 251 251 244 236 229 S= 3000 psi 400 F S= 10,300 psi 100 F S= 10,300 psi 150 F S= 10,300 psi 200 F S= 10,300 psi 250 F S= 10,000 psi 300 F S= 9,700 psi 350 F S= 9,400 psi 400 F ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. Elkhart Products Corporation 11 Wrot & Cast Pressure Fittings Tees Nominal Size Box Master Approx. Dim. Dim. Dim. In Inches Quantity Pack Net Wt. A B C 3/4 x 3/4 x 1/2 25 250 0.109 25/64 25/64 19/32 3/4 x 3/4 x 3/8 25 250 0.130 25/64 25/64 11/16 3/4 x 3/4 x 1/4 25 250 0.135 25/64 25/64 3/4 * 3/4 x 5/8 x 5/8 25 250 0.150 1/2 11/16 3/4 3/4 x 1/2 x 3/4 25 250 0.144 1/2 25/32 17/32 3/4 x 1/2 x 1/2 25 250 0.109 25/64 5/8 19/32 * 3/4 x 1/2 x 3/8 25 250 0.137 25/64 5/8 11/16 3/4 x 1/2 x 1/4 25 250 0.140 25/64 5/8 3/4 * 3/4 x 3/8 x 3/4 25 250 0.159 1/2 29/32 17/32 * 3/4 x 3/8 x 1/2 25 250 0.140 25/64 23/32 19/32 * 3/4 x 3/8 x 3/8 25 250 0.132 25/64 23/32 11/16 1 x 1 x 1 1/2 5 50 0.680 1 1/4 1 1/4 1 5/32 1 x 1 x 1 1/4 5 50 0.405 1 5/32 1 5/32 31/32 1 x 1 x 3/4 10 100 0.223 1/2 1/2 5/8 * 1 x 1 x 5/8 10 100 0.319 1/2 1/2 15/16 1 x 1 x 1/2 10 100 0.186 23/64 23/64 11/16 1 x 1 x 3/8 10 100 0.185 23/64 23/64 13/16 1 x 3/4 x 1 10 100 0.290 21/32 53/64 21/32 1 x 3/4 x 3/4 10 100 0.220 1/2 11/16 5/8 1 x 3/4 x 1/2 10 100 0.185 23/64 9/16 11/16 * 1 x 3/4 x 3/8 10 100 0.270 23/64 9/16 13/16 * 1 x 5/8 x 5/8 10 100 0.313 1/2 11/16 15/16 * 1 x 5/8 x 1/2 10 100 0.272 23/64 9/16 11/16 1 x 1/2 x 1 10 100 0.290 21/32 5/64 21/32 1 x 1/2 x 3/4 10 100 0.220 1/2 15/16 5/8 1 x 1/2 x 1/2 10 100 0.185 23/64 13/16 11/16 1 x 1/2 x 3/8 10 100 0.185 23/64 13/16 13/16 1 1/4 x 1 1/4 x 2 5 40 1.352 1 3/4 1 3/4 1 3/8 1 1/4 x 1 1/4 x 1 1/2 5 50 0.680 1 3/16 1 3/16 1 5/32 1 1/4 x 1 1/4 x 1 5 50 0.348 17/32 17/32 25/32 1 1/4 x 1 1/4 x 3/45 50 0.301 7/16 7/16 3/4 1 1/4 x 1 1/4 x 1/25 50 0.259 19/64 19/64 11/16 1 1/4 x 1 x 1 1/4 5 50 0.405 7/8 7/8 25/32 1 1/4 x 1 x 1 5 50 0.391 3/4 3/4 25/32 1 1/4 x 1 x 3/4 5 50 0.297 5/8 5/8 25/32 1 1/4 x 1 x 1/2 5 50 0.256 1/2 1/2 25/32 1 1/4 x 3/4 x 1 1/45 50 0.405 7/8 7/8 25/32 1 1/4 x 3/4 x 1 5 50 0.391 3/4 3/4 25/32 1 1/4 x 3/4 x 3/4 5 50 0.297 5/8 5/8 25/32 1 1/4 x 3/4 x 1/2 5 50 0.256 1/2 1/2 25/32 1 1/4 x 1/2 x 1 1/45 50 0.405 7/8 7/8 25/32 **1 1/4 x 1/2 x 1 12 72 0.470 - - - 1 1/2 x 1 1/2 x 2 5 50 1.352 1 37/64 1 37/64 1 3/8 1 1/2 x 1 1/2 x 1 1/4 5 50 0.482 11/16 11/16 13/16 1 1/2 x 1 1/2 x 1 5 50 0.387 9/16 9/16 13/16 1 1/2 x 1 1/2 x 3/45 50 0.342 7/16 7/16 13/16 1 1/2 x 1 1/2 x 1/25 50 0.310 21/64 21/64 29/32 1 1/2 x 1 1/4 x 1 1/2 5 50 0.680 1 7/32 1 3/16 1 7/32 1 1/2 x 1 1/4 x 1 1/45 50 0.661 31/32 1 3/16 1 1/16 1 1/2 x 1 1/4 x 1 5 50 0.591 27/32 1 3/16 1 1/16 1 1/2 x 1 1/4 x 3/45 50 0.583 11/16 7/8 31/32 1 1/2 x 1 1/4 x 1/25 50 0.460 9/16 13/16 31/32 Nominal Size Box Master Approx. Dim. Dim. Dim. In Inches Quantity Pack Net Wt. A B C 1/8 50 1000 0.014 13/64 13/64 7/32 5/16 OD 50 1000 0.020 7/32 7/32 9/32 1/4 50 1000 0.028 17/64 17/64 1/4 3/8 50 500 0.045 5/16 5/16 3/8 1/2 50 500 0.056 21/64 21/64 11/32 5/8 25 250 0.110 7/16 7/16 1/2 3/4 25 250 0.144 1/2 1/2 17/32 1 10 100 0.291 21/32 21/32 21/32 1 1/4 5 50 0.397 41/64 41/64 41/64 1 1/2 5 50 0.540 13/16 13/16 13/16 2 5 40 1.082 1 1/16 1 1/16 1 15/64 2 1/2 1 10 1.967 1 21/32 1 21/32 1 11/16 3 1 10 2.744 1 7/8 1 7/8 1 11/16 3 1/2 1 8 4.167 2 5/32 2 5/32 2 1/4 4 1 8 6.396 2 13/32 2 13/32 2 9/16 * 5 1 1 7.998 2 37/64 2 37/642 29/32 * 6 1 1 12.613 3 1/8 3 1/8 3 11/16 * 8 1 1 32.086 4 1/16 4 1/16 4 3/4 * 3/8 x 3/8 x 3/16 OD50 1000 0.028 17/64 17/64 7/16 1/8 x 1/8 x 1/4 50 1000 0.028 13/32 13/32 1/4 1/4 x 1/4 x 1/2 50 500 0.063 21/32 21/32 11/32 1/4 x 1/4 x 3/8 50 500 0.045 15/32 15/32 3/8 1/4 x 1/4 x 1/8 50 1000 0.028 17/64 17/64 13/32 1/4 x 1/8 x 1/4 50 1000 0.028 17/64 13/32 1/4 1/4 x 1/8 x 1/8 50 1000 0.028 17/64 13/32 13/32 3/8 x 3/8 x 1/2 50 500 0.063 17/32 17/32 11/32 3/8 x 3/8 x 1/4 50 500 0.045 5/16 5/16 15/32 3/8 x 3/8 x 1/8 50 500 0.045 5/16 5/16 39/64 * 3/8 x 1/4 x 1/2 50 500 0.063 17/32 21/32 11/32 3/8 x 1/4 x 1/4 50 500 0.045 5/16 15/32 15/32 * 3/8 x 1/4 x 1/8 50 500 0.045 5/16 15/32 5/8 3/8 x 1/8 x 3/8 50 500 0.045 5/16 9/16 3/8 1/2 x 1/2 x 1 10 100 0.290 15/16 15/16 3/4 1/2 x 1/2 x 3/4 25 250 0.118 33/64 33/64 15/32 1/2 x 1/2 x 3/8 50 500 0.061 5/16 5/16 13/32 1/2 x 1/2 x 1/4 50 500 0.061 9/32 9/32 13/32 1/2 x 1/2 x 1/8 50 500 0.061 9/32 9/32 1/2 1/2 x 3/8 x 1/2 50 500 0.063 3/8 17/32 11/32 1/2 x 3/8 x 3/8 50 500 0.061 5/16 1/2 13/32 1/2 x 1/4 x 1/4 50 500 0.061 9/32 5/8 13/32 3/4 x 3/4 x 1 10 100 0.202 3/4 3/4 17/32 * 3/4 x 3/4 x 5/8 25 250 0.153 1/2 1/2 3/4 WROT CAST 111 Tee-cont. 4711 Copper to Copper to Copper B C A C x C x C WROT CAST 111 Tee 4711 Copper to Copper to Copper Nominal Size Box Master Approx. Dim. Dim. In Inches Quantity Pack Net Wt. A B 1/8 50 1000 0.006 1/4 1/4 1/4 50 1000 0.012 3/8 3/8 3/8 50 1000 0.026 13/32 13/32 1/2 100 1000 0.039 25/64 25/64 5/8 25 250 0.069 17/32 17/32 3/4 50 500 0.087 9/16 9/16 1 20 200 0.168 47/64 47/64 1 1/4 25 200 0.300 15/16 15/16 1 1/2 20 120 0.404 1 11/64 1 11/64 2 10 80 0.748 1 29/64 1 29/64 2 1/2 5 40 1.200 1 21/32 1 21/32 3 3 24 1.920 1 61/64 1 61/64 3 1/2 1 8 2.728 2 7/32 2 7/32 4 1 8 4.290 2 17/32 2 17/32 5 1 1 8.586 3 1/8 3 1/8 6 1 1 15.200 3 13/16 3 13/16 8 1 1 37.000 5 1/8 5 1/8 Wrot & Cast Pressure Fittings Elbows 8 Elkhart Products Corporation Asubsidiary of Amcast Industrial Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. Nominal Size Box Master Approx. Dim. Dim. In Inches Quantity Pack Net Wt. A B 1/4 50 1000 0.013 15/64 41/64 3/8 50 1000 0.024 9/32 23/32 1/2 100 1000 0.035 5/16 25/32 5/8 25 250 0.059 27/64 1 1/16 3/4 50 500 0.076 13/32 1 3/16 1 25 250 0.134 7/16 1 7/16 1 1/4 25 200 0.229 17/32 1 9/16 1 1/2 20 160 0.343 19/32 1 3/4 2 10 80 0.625 25/32 2 3/16 2 1/2 5 40 0.965 29/32 2 7/16 3 3 24 1.470 1 2 11/16 *3 1/2 1 16 2.100 1 5/32 3 4 1 8 3.340 1 9/32 3 1/2 WROT CAST 106-2 45°Street Elbow Fitting to Copper B A A B FTG. x C C x C WROT CAST 107-C 90°Elbow-Close Ruff 4707 Copper to Copper Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 1/4 50 1000 0.013 15/64 3/8 50 1000 0.024 1/4 1/2 100 1000 0.036 17/64 5/8 25 250 0.063 7/16 3/4 50 500 0.077 3/8 1 25 250 0.137 13/32 1 1/4 25 200 0.229 33/64 1 1/2 20 160 0.343 19/32 2 10 80 0.625 25/32 2 1/2 5 40 0.970 7/8 3 3 24 1.460 63/64 3 1/2 1 16 2.180 1 5/32 4 1 8 3.376 1 11/64 5 1 6 6.564 1 13/32 6 1 1 11.200 1 11/16 8 1 1 27.900 2 1/4 A A C x C WROT CAST 106 45° Elbow Copper to Copper Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 3/8 25 500 0.033 1 3/16 1/2 25 250 0.056 1 7/16 3/4 25 250 0.12 2 1 10 100 0.224 2 15/32 1 1/4 5 50 0.388 2 29/32 1 1/2 5 50 0.560 3 5/16 2 5 40 1.156 4 3/8 A A FTG. x FTG. WROT CAST 105-L90°Street Elbow-Long Turn Fitting to Fitting WROT CAST 101 Coupling Without Stop Copper to Copper Wrot & Cast Pressure Fittings Couplings 4 Elkhart Products Corporation Asubsidiary of Amcast Industrial Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 1/4OD x 3/16 OD 50 1000 0.004 3/32 3/8OD x 5/16 OD 50 1000 0.008 3/32 1/4 x 1/8 50 1000 0.008 5/32 3/8 x 1/4 50 1000 0.017 3/16 3/8 x 1/8 50 1000 0.019 1/4 1/2 x 3/8 50 1000 0.026 5/32 1/2 x 1/4 50 1000 0.024 1/4 1/2 x 1/8 50 1000 0.025 23/64 5/8 x 1/2 25 500 0.035 5/32 5/8 x 3/8 25 500 0.036 7/32 5/8 x 1/4 25 500 0.043 5/16 3/4 x 5/8 50 500 0.066 3/16 3/4 x 1/2 50 500 0.061 3/16 3/4 x 3/8 50 500 0.052 21/64 3/4 x 1/4 50 500 0.053 7/16 1 x 3/4 25 250 0.098 13/32 1 x 5/8 25 250 0.102 3/8 1 x 1/2 25 250 0.104 7/16 1 x 3/8 25 250 0.093 1/2 1 1/4 x 1 10 100 0.152 5/16 1 1/4 x 3/4 10 100 0.134 15/32 1 1/4 x 1/2 10 100 0.165 41/64 1 1/2 x 1 1/4 10 100 0.220 11/32 1 1/2 x 1 10 100 0.220 7/16 1 1/2 x 3/4 10 100 0.218 21/32 1 1/2 x 1/2 10 100 0.219 25/32 2 x 1 1/2 10 100 0.366 13/32 Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 2 1/2 5 50 0.616 3 1/32 3 5 40 0.912 3 13/32 3 1/2 1 16 1.352 3 29/32 4 2 16 1.878 4 13/32 5 1 6 3.365 5 1/2 6 1 6 5.262 6 3/8 8 1 1 12.941 8 1/4Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 3/16 OD 50 1000 0.002 1/16 5/16 OD 50 1000 0.006 1/16 1/8 50 1000 0.004 1/16 1/4 50 1000 0.007 3/32 3/8 50 1000 0.014 3/32 1/2 100 1000 0.021 3/32 5/8 25 500 0.040 3/32 3/4 50 500 0.048 3/32 7/8 10 200 0.084 3/32 1 25 250 0.088 3/32 1 1/4 20 200 0.144 3/32 1 1/2 10 100 0.216 3/32 2 5 50 0.391 3/32 2 1/2 5 50 0.624 3/32 3 5 40 0.909 3/32 3 1/2 1 16 1.369 3/32 4 2 16 1.904 3/32 5 1 6 3.365 3/16 6 1 6 5.262 3/16 8 1 1 12.941 1/8 Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 1/4 50 1000 0.006 23/32 3/8 50 1000 0.013 55/64 1/2 100 1000 0.019 1 3/32 3/4 50 500 0.046 1 19/32 1 25 250 0.087 1 29/32 1 1/4 20 200 0.149 2 1/32 1 1/2 10 100 0.213 2 17/64 2 5 50 0.391 2 49/64 A A WROT CAST 101 Coupling Without Stop-cont. Copper to Copper WROT CAST 101-R Coupling With Stop 4701-R Copper to Copper A C x C C x C C x C WROT CAST 100 Coupling With Stop Copper to Copper Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 1/8 50 1000 0.0187 13/32 1/4 50 1000 0.027 15/32 3/8 50 500 0.041 7/8 1/2 50 500 0.064 19/32 3/4 25 250 0.119 13/16 1 20 200 0.160 27/32 1 1/4 10 100 0.317 15/16 1 1/2 10 100 0.443 7/8 2 5 50 0.675 1 11/32 2 1/2 4 40 1.267 1 21/32 3 2 20 2.138 1 25/32 4 1 16 3.500 1 29/32 **5 5 5 8.600 - **6 4 4 10.730 - 1/8 x 3/8 50 1000 0.040 3/4 Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 1/4 50 1000 0.030 29/32 3/8 50 1000 0.049 1 1/16 1/2 50 500 0.084 1 3/8 3/4 25 250 0.143 1 11/16 1 20 200 0.214 1 31/32 1 1/4 10 100 0.324 2 5/32 1 1/2 10 100 0.437 2 7/16 2 5 50 0.641 2 19/32 **2 1/2 25 25 1.740 - **3 20 20 2.470 - 1/2 x 3/8 50 500 0.062 1 1/8 1/2 x 1/4 50 500 0.041 59/64 **3/4 x 1/2 25 225 0.147 - **1 x 3/4 25 250 0.414 - **1 x 1/2 25 250 0.153 - A 6 Elkhart Products Corporation Asubsidiary of Amcast Industrial Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. Nominal Size Box Master Approx. Dim. In Inches Quantity Pack Net Wt. A 1/8 50 1000 0.029 7/16 1/4 50 1000 0.031 15/32 3/8 50 500 0.053 19/32 1/2 50 500 0.086 7/8 3/4 25 250 0.143 23/32 1 20 200 0.226 31/32 1 1/4 10 100 0.304 1 3/32 1 1/2 10 100 0.404 1 5/32 2 5 50 0.650 1 1/4 2 1/2 2 20 1.228 1 1/2 **3 12 12 2.400 - **4 12 12 3.820 - **5 6 6 8.250 - **6 4 4 12.000 - 1/8 x 1/4 50 1000 0.033 1/2 1/4 x 1/2 50 500 0.078 25/32 1/4 x 3/8 50 1000 0.043 21/32 1/4 x 1/8 50 1000 0.024 11/32 3/8 x 1/2 50 500 0.082 7/8 3/8 x 1/4 50 1000 0.041 15/32 **1/2 x 1 25 150 0.300 - 1/2 x 3/4 25 250 0.121 29/32 1/2 x 3/8 50 500 0.046 9/16 1/2 x 1/4 50 500 0.044 15/32 5/8 x 3/4 25 250 0.143 1 5/8 x 1/2 25 250 0.102 3/4 **3/4 x 1 1/4 10 100 0.515 - 3/4 x 1 20 200 0.218 1 7/32 3/4 x 1/2 25 250 0.085 19/32 **1 x 1 1/2 10 100 0.720 - 1 x 1 1/4 10 100 0.299 1 7/32 1 x 3/4 25 250 0.159 43/64 1 x 1/2 10 100 0.239 11/16 **1 1/4 x 2 5 50 0.980 - 1 1/4 x 1 1/2 10 100 0.431 1 19/64 1 1/4 x 1 10 100 0.238 55/64 **1 1/4 x 3/4 100 100 0.290 - 1 1/2 x 2 5 50 0.678 1 7/16 1 1/2 x 1 1/4 10 100 0.388 7/8 **1 1/2 x 1 60 60 0.370 - 2 x 1 1/2 5 50 0.730 1 3/16 A A C x F C x M FTG. x F WROT CAST 103 Female Adapter 4703 Copper to Female N.P.T. WROT CAST 103-2 Female Street Adapter 4703-2 Fitting to Female N.P.T. WROT CAST 104 Male Adapter 4704 Copper to Male N.P.T. Wrot & Cast Pressure Fittings Adapters Page 1 of1Print 11/2/2011http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1962 Hilti Product Technical Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com • Hilti Canada: 1-800-363-4458 / www.ca.hilti.com134 Anchoring Systems 4.3.5HDI / HDI-L Drop-In Anchor Anchor Size in. 1/ 4 3 /8 1 /2 5 /8 3/4 Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1) d bit: bit diameter1 in. 3 /8 1 /2 5 /8 27/32 1 h nom: std.depth of embed. in. 1 19/16 2 2 9 /16 3 3/16 : anchor length (mm) (25) (40) (51) (65) (81) h1: hole depth  th: useable thread in. 7/ 16 5/8 11 /16 7/8 1 3/8 length (mm) (11) (15) (17) (22) (34) Threads per in. 20 16 13 11 10 h: min.base material in. 3 31/ 8 4 5 1 /8 6 3/8 thickness (mm) (76) (79) (102) (130) (162) Tinst: max. tightening ft lb 4 11 22 37 80 torque (Nm) (5.4) (14.9) (29.8) (50.2) (108.5) 4.3.4.1 PRODUCT DESCRIPTION The Hilti HDI/HDI-L Drop-In anchor is an internally threaded, flush mounted expansion anchor for use in concrete. Product Features Guide Specifications Expansion Anchors: Expansion anchors shall be flush or shell type which meet the description in Federal Specification FF-S-325, Group VIII, Type 1, for expansion shield anchors. Anchors to be zinc plated in accordance with ASTM B633, Sc. 1, Type III. Anchors shall be Hilti HDI/HDI-L anchors as supplied by Hilti, Inc., P.O. Box 21148, Tulsa, OK 74121. Installation: Shell or flush type anchors to be installed in holes drilled with Hilti carbide tipped drill bits. Anchors shall be installed per manufacturer’s recommendations. Approvals/Listings • City of Los Angeles (COLA): Research Report No. 23709 (HDI Only) • Factory Mutual (FM): Serial No. 22765 “Sprinkler Hangar Components—Expansion Shields.” (HDI and HDI-L) • Conforms to the description in Federal Specification FF-S-325, Group VIII, Type 1 for expansion shield anchors. (HDI and HDI-L) • Underwriters Laboratory (UL), “Pipe Hangers” (3/8"–3/4" diameter) (HDI and HDI-L) • International Conference of Building Officials (ICBO ES): Evaluation Report No. 2895 (HDI Only) • Southern Building Code Congress (SBCCI): Report No. 9930 (HDI Only) 4.3.5.2 MATERIAL SPECIFICATIONS HDI/HDI-LCarbon Steel material meets the requirements of AISI 1010M for the 1/4", 3/8" & 1/2” HDI Carbon Steel material meets the requirements of AISI 12L14 for the 5/8” and 3/4” sizes HDIStainless Steel material meets the requirements of AISI303 Carbon Steel HDI/HDI-L plated with a dull zinc finish for corrosion protection in accordance with ASTM B633, Sc. 1, Type III 4.3.5.3 TECHNICAL DATA HDI/HDI-LSpecification Table Combined Shear and Tension Loading (Ref. Section 4.1.3) ≤ 10 44 (303) 53 (365) 60 (415) 78 (540) 60 (414) 100 (689) MECHANICALPROPERTIES fy min. fuksi (MPa) ksi (MPa) HDI/HDI-L HDI/HDI-L HDI/HDI-L HDI HDI HDI • Anchor, setting tool & Hilti drill bit form a matched tolerance system to provide reliable fastenings • Below surface setting for easy patchwork • Allows for shallow embedment without sacrificing performance HDI-L • Lip provides flush installation, consistent anchor depth, and easy rod alignment • Lip allows accurate flush surface setting, independent of hole depth & ideal for repetitive fastenings with threaded rods of equal length • Intelligent expansion section adapts to the base material & reduces number of hammer blows up to 50% • Easy to read brand & size identification (red laser print) 1.For Hilti matched tolerance carbide tipped drill bits, see section 10.4.1. 5/10/2001-71- ToL c 0 INCORPORATED CORONA, CA (909)737-5599 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4 and 1-1/4 Inch Throat Openings Size Range – (Fig. 65 and Fig. 66) 3/8, 1/2, AND 5/8 inch rod. Material –CarbonSteel withhardenedcuppointsetscrew andjamnut. Function – Recommended for hanging from steel beam where flange thickness does not exceed 3/4 inch (Fig. 65) or 1-1/4" (Fig. 66) Features – All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals– Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering Approved. Conforms to Federal Specification Society SP-69, type 19 and 23. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet #13, 3/8 inch rod will support 1/2 thru 4 inch pipe, 1/2 inch rod will support 1/2 thru 8 inch pipe. Finish – Plain. Note—Available in Electro-Galvanized and HDG finish. Order By—Figure number, rod size, and finish. Fig. 65 Patent #4,570,885 F I G . 6 5 T A B L E ROD MAX. REC. APPROXB C D E FSIZEA LOAD LBS.* WT./100 3/8 1-3/16 3/4 1 7/16 1 610 28 1/2 1-1/2 3/4 1 9/16 1-1/4 1130 55 5/8 1 -1/2 3/4 1 9/16 1 -1/4 1130 55 *Max. loads forclamp with set screw in up ordown position. FIG. 66 TABLE ROD MAX. REC. APPROXB C D E FSIZEA LOAD LBS.* WT./100 3/8 1-3/16 1-1/4 1 7/16 1 610 28 1/2 1-1/2 1-1/4 1 9/16 1-1/4 1130 55 5/8 1-1/2 1-1/4 1 9/16 1-1/4 1130 55 *Max. loads for clamp with set screw in up or down position. 5/10/2001-82- ToLc0 INCORPORATED CORONA, CA (909)737-5599 Fig. 98 Rod Stiffener Size Range—Secures 3/8 thru 7/8 inch hanger rod. Material – Carbon Steel. Function—Secures channel to hanger rod for vertical seismicbracing. Finish—Electro Galvanized. Order By—Figure number. Note—AvailableinHDGfinishor StainlessSteel materials. Fig. 99 All Thread Rod Cut To Length Fig. 100 All Thread Rod Full Lengths ROD SIZE MAX.REC.LOADLBS. FORSERVICETEMPS 650°F 750°F APPROX. WEIGHT PER100FT. 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1-1/4 8000 7140 360 1-1/2 11630 10370 510 Size Range-3/8 thru 7/8 inch rod in 1 inch increments. Material – Carbon Steel. Maximum Temperature-750°F. Finish— Plain. Order By—Figure number, rod diameter, rod length, and finish. Note—AvailableinElectro-Galvanized and HDG finish or Stainless Steel materials. ROD SIZE MAX.REC.LOADLBS. FORSERVICETEMPS 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Size Range-3/8 thru 7/8 inch rod in 10 foot lengths. Material – Carbon Steel. Maximum Temperature-750°F. Finish— Plain. Order By—Figure number, rod diameter, and finish. Note— Available in Electro- Galvanized and HDG finish or Stainless Steel materials. 5/10/2001-103- To'. c 0 INCORPORATED CORONA, CA (909)737-5599 Fig. 200 ®c®"Trimline" Adjustable Band Hanger Size Range — 1/2 thru 8 inch pipe. Material — CarbonSteel, Mil. GalvanizedtoG-90 specifications. Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features  (1/2 thru2 inch) Flared edges ease installationfor all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe.  (2-1/2 thru 8 inch) Spring tension on nut holds it securelyinhanger beforeinstallation. Adjustingnutis easilyremoved. Approvals— Underwriters' Laboratories Listed (1/2" thru 8") in the U.S. (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10, and Manufacturers StandardizationSocietySP-69, type 10. Maximum Temperature - 650°F. Finish — Mil. Galvanized, for Stainless Steel materials order Tolco Fig. 200WON. Order By— Figure number and pipe size. 1/2THRU2INCH PIPE 2 1/2 THRU 8 INCH PIPE PIPE SIZE INCH ROD SIZE METRIC* A B MAX. REC. LOAD LBS. APPROX. WT./100 1/2 3/8 8mm or 10mm 3-1/8 2-5/8 400 11 3/4 3/8 8mm or 10mm 3-1/8 2-1/2 400 11 1 3/8 8mm or 10mm 3-3/8 2-5/8 400 12 1-1/4 3/8 8mm or 10mm 3-3/4 2-7/8 400 13 1-1/2 3/8 8mm or 10mm 3-7/8 2-7/8 400 14 2 3/8 8mm or 10mm 4-1/2 3 400 15 2-1/2 3/8 10mm 5-5/8 4-1/8 600 27 3 3/8 10mm 5-7/8 4 600 29 3-1/2 3/8 10mm 7-3/8 5-1/4 600 34 4 3/8 10mm 7-3/8 5 1000 35 5 1/2 12mm 9-1/8 6-1/4 1250 66 6 1/2 12mm 10-1/8 6-3/4 1250 73 8 1/2 12mm 13-1/8 8-3/4 1250 136 *Order Fig. 200M