Loading...
HomeMy WebLinkAboutwindow specs_5 (2).pdfMarvin Order Management Performance Summary Report Date/Time: 7/20/2016 5:14 PM Job/Project Name: POLIDORI, RANDIE/ 07/12/16 Sales Rep: MIKE GRAVINA PK Version: 0002.09.00 Quote/Order Number: CVHZEVB Organization Name: GRAVINA WINDOW CENTER Line Mark Unit Unit ID Brand Product Size U-Factor SHGC VLT CR 1 2ND SOUTH LOFT Al Infinity Casement Picture 29 5/B x 70 5/B 0.30 0.23 0.53 55 2ND NORTH LOFT Al Infinity Casement Picture 29 5/B x 70 5/B 0.30 0.23 0.53 55 3RD WEST LOFT Al Infinity Awning 42 5/B x 22 5/B 0.31 0.20 0.46 54 4 3RD WEST LOFT Al Infinity Awning 42 5/B x 22 5/B 0.31 0.20 0.46 54 3RD WEST LOFT Infinity P4 Direct Glaze 39X73 XSS 0.31 0.24 O.SS 57 3RD WEST LOFT Infinity P4 Direct Glaze 39 X 73 X SS 0.31 0.24 o.ss 57 3RD WEST DINING ROOM Infinity P4 Direct Glaze 72X60X24 0.31 0.24 o.ss 57 8 2ND WEST DINING ROOM Al Infinity Rectangle 72 X42 0.31 0.24 0.55 57 9 WEST DINING ROOM Al Infinity Infinity Assembly 73 1/4 x S2 1/2 0.30 0.20 0.46 S6 9 WEST DINING ROOM A2 Infinity Infinity Assembly 0.30 0.23 O.S3 55 WEST DINING ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 S6 10 SOUTH DINING ROOM Al Infinity Infinity Assembly 73 1/4 x 52 1/2 0.30 0.20 0.46 56 10 SOUTH DINING ROOM A2 Infinity Infinity Assembly 0.30 0.23 O.S3 55 10 SOUTH DINING ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 56 11 2ND SOUTH DINING ROOM Al Infinity Rectangle 7S X461/2 0.30 0.24 O.S5 57 12 2ND WEST NOOK Al Infinity Casement 30 7/B x 54 3/4 0.30 0.20 0.46 56 13 3RD WEST NOOK Infinity P4 Direct Glaze 2B x 104 x 90 14 2ND SOUTH FAMILY ROOM Al Infinity Infinity Assembly 73 1/4 x 54 3/4 0.30 0.20 0.46 S6 14 2ND SOUTH FAMILY ROOM A2 Infinity Infinity Assembly 0.30 0.23 O.S3 SS 14 2ND SOUTH FAMILY ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 S6 IS 3RD SOUTH FAMILY ROOM Infinity P4 Direct Glaze 74X82X4B 16 2ND SOUTH FAMILY ROOM Al Infinity Infinity Assembly 73 1/4 x 54 3/4 0.30 0.20 0.46 56 16 2ND SOUTH FAMILY ROOM A2 Infinity Infinity Assembly 0.30 0.23 0.53 55 16 2ND SOUTH FAMILY ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 56 17 3RD SOUTH FAMILY ROOM Infinity P4 Direct Glaze 74 x 82 x 48 18 BASEMENT SOUTH BEDROOM Al Infinity Infinity Assembly 73 1/4 x 42 3/4 0.30 0.20 0.46 56 IS BASEMENT SOUTH BEDROOM A2 Infinity Infinity Assembly 0.30 0.23 0.53 SS IB BASEMENT SOUTH BEDROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 56 19 WEST FAMILY ROOM Al Infinity Casement 30 S/8 X 54 3/4 0.30 0.20 0.46 56 20 2ND WEST FAMILY ROOM Infinity P4 Direct Glaze 29X46X28 0.31 0.24 O.S5 57 lill!!!m. Certified Product Directory (CPD) Number - a unique number used by the NFRC to organize product listing of certified products. Condensation Resistance (CR): Measures the ability of a product to resist the formation of condensation on the interior surface of that product. The higher the CR rating the better it resists forming condensation. ENERGY STAR is a program of the U.S. Environmental Protection Agency designed to recognize products that meet strict energy efficiency guidelines. Learn more about ENERGY STAR. Solar Heat Gain Coefficient (SHGC) measures how well a product blocks heat from the sun. In warm climates, the lower the number, the better. Here you want to keep heat out by choosing windows that reflect solar radiation. Less heat coming into the home means lower air-conditioning costs and a reduced carbon footprint. In cold regions, your windows can also help you take advantage of solar radiation, which is free heat that eases the workload of your furnace or other energy-powered heat source. A higher solar heat gain coefficient means a window will allow more heat to pass through. U-Factor: (Btu/hr.-sq. ft. -•f.) A measurement of the amount of heat flow through a product. The lower the U-factor, the greater the resistance to heat flow and better its insulating value. The National Fenestration Rating Council (NFRC) has developed and operates a uniform national rating system for the energy performance of fenestration products, including windows and doors. For additional information regarding this rating system, see www.nfrc.org/WindowRiltings. NFRC energy ratings and values may vary depending on the exact configuration of glass thickness used on the unit. This data may change over time due to ongoing product changes or updated test results or requirements. Infinity Casement and Awning Unit Features.......................................................................................................................................................... 1 Lite Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Minimum and Maximum Guidelines....................................................................................................................... 4 Certified Sizes and Ratings.................................................................................................................................... 5 STC/OITC Glass Values . . . .. . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . 6 Mulling Guidelines.................................................................................................................................................. 7 1/2" Mull Reinforcement Guidelines....................................................................................................................... 8 Measurement Conversions: Operable Units . . . . . . . . .. . . .. . . . . . . . . . .. . . . . . . . . . .. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . 9 Measurement Conversions: Picture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Measurement Conversions: Egress -Easy Wash™ . . . . . . . . . . . . .. . . . . . . . . .. . . . . . .. . . . . .. . . . . . .. . . . . .. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . .. .. . . . . . . . . 11 Measurement Conversions: Egress -Clear View................................................................................................... 12 Section Details: Operating and Picture . . . .. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Section Details: Casing Options............................................................................................................................. 14 Section Details: Mullions . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . .. .. . . . . . . . . . . . . . . . . . . . . . .. . . . . .. . . 15 Section Details: 1/2" Mull Reinforcement............................................................................................................... 16 Interior Frame Accessories.................................................................................................................................... 17 CHECK MARVIN ONLINE DOCS FOR LATEST. VERSION Printed On: Jul 14, 2016, 3:41 pm I 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Unit Features Infinity Casement: NCA Infinity Awning: NAWN Infinity Casement Picture: NCAP Ultrex® Pultruded Fiberglass Frame: •Frame thickness: 1 5/16" (33) •Frame depth: 2 5/32" (55) • Exterior colors: Stone White, Sierra, Cashmere, Pebble Gray, Bahama Brown, Bronze •Interior colors: Stone White, Sierra, EverWood™ Ultrex® Pultruded Fiberglass Sash: • Sash thickness: 1 3/8" (35) • Operating sash is removable for cleaning • Sash are replaceable but cannot be re-glazed • Exterior colors: Stone White, Sierra, Cashmere, Pebble Gray, Bahama Brown, Bronze • Interior colors: Stone White, Sierra, EverWood™ Casement Hardware: • Lock and keeper: INFINITY h···MARVIN 0 Multi-point locking mechanism that is actuated from a single point of operation. Lock mechanisms are concealed with only the actuator handle and escutcheon being visible to the interior. Keepers are mounted to the interior face of the sash and interlocks within concealed lock when actuated. •Operator: ° Concealed hinges with stainless steel tracks 0 Snubber: pulls the sash tight to the frame and provides positive engagement to secure the sash under structural load conditions 0 Dual arm roto-gear operator on units 24 3/8" (619) wide frame size and over 0 Split-arm rote-gear operator used on units less than 24 3/8" (619) wide •Handle: 0 Die-cast folding crank handle •Factory installed Window Opening Control Device (WOCD): 0 Minimum Frame OSM 18 5/32" (461) x 17 3/8" (441) 0 Maximum Frame OSM 40" (1016) x 60" (1524) or 36" (914) x 86" (2184) 0 WOCD locking assembly: • Factory installed •Die-cast • Color: White, Satin Taupe, Sierra 0 WOCD tether assembly: factory installed, glass filled nylon • Color: E-Gard color match Awning Hardware: • Lock and keeper: ° Cam lock and stainless steel keeper system •Operator: ° Concealed hinges and steel tracks ° Factory installed rote-gear operator •Handle: 0 Die-cast folding crank handle • Sash Limiter: ° Factory installed or field applied Weather Strip: •Frame: 0 Extruded foam bulb weather strip that runs around the perimeter of the frame sealing against the interior face of the sash • Color: black .sash: 0 Extruded thermoplastic bulb that attaches to a kerf around the top, bottom and sides of the sash; sealing against the inner perimeter of the frame • Color: beige or black • Black is for Bahama Brown and Bronze exterior units CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2015.1 2015-08-31 NCA I NAWN-1 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Unit Features: Insect Screens: •Full screen • Roll formed aluminum frame • Mitered corner key; injection molded, color matched to screen • Color: Stone White, Satin Taupe, Sierra, EverWood ™ •Standard screen mesh material: charcoal fiberglass 0 Optional screen mesh material: high transparency Glass: • Glazing seal: silicone bedding on interior and exterior • Standard glass: Low E2 with Argon or air INFINITY lv·oMARVIN •Optional glazing available: Low E1 with Argon or air, Low E3 with Argon or air, or Low E3/ERS with Argon or air, clear, tints, tempered, obscure •Decorative glass options include Glue Chip, Rain, Reed, Narrow Reed, or Frost •Decorative glass is not available with Low E1, Low E3/ERS, or STC/OITC •Rain, Reed and Narrow Reed not available with SDL •SOL available on Frost, annealed or tempered glass • SDL available on Glue Chip, tempered glass required • Insulating glass will be altitude adjusted with capillary tubes for higher elevations •Argon gas is not available for elevations that require capillary tubes Simulated Divided Lites (SOL): • 718" (22) or 1 1/8" (29) SDL bar (interior and exterior) • 2 11/32" (30) simulated rail (interior and exterior) • Exterior color: matched to unit exterior • Interior color: matched to interior -ABS material • Pattern: equal rectangular, cottage, prairie, check rail Gilles-Between-the-Glass (GBG): e 11/16" (18) or 1" (25) contoured aluminum bar • Exterior: color matched to unit exterior •The exterior GBG color is designed to best match the unit exterior color when used with Low E glass. The use of different types of glazing options may alter the exterior GBG color appearance. • Interior color: White, Satin Taupe, Sierra, Bronze • Pattern: equal rectangular, cottage, prairie, check rail NOTE: GBG may not be available or may require tempered glass if the glass size is greater than 16 square feet or if the short side dimension is greater than 48". Please contact your local Infinity Retailer or Infinity Support at 800-372-1072 to determine if GBG is available for glass sizes exceeding these dimensions. CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2015.1 2015-06-29 NCA I NAWN-2 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Lite Options Insulating Glass -1 L--11/16" ' (18) ~----=='---l~c~ ~ ~c;~=~#~f 't~ [:;_ _ __ , ===' 11 /16" Insulating Glass GBG 1" Insulating Glass GBG 0 \ 0 Insulating Glass SOL Simulated Rail w/ spacer bar Insulating Glass 7/8" SOL w/ spacer bar Insulating Glass 1 1/8" SOL w/ spacer bar INFINITY 1-c,.,MARYIN CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2015.1 2015-06-29 NCA I NAWN-3 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Minimum and Maximum Guidelines Minimum and Maximum Guidelines Frame Size UnitType Min Width Min Height Max Width Max Height in mm in mm in mm in 161/4 (413) 17 3/8 (441) 40 (1016) 60 NGA 161/4 (413) 17 3/8 (441) 36 (914) 86 NAWN 171/2 (445) 17 3/8 (441) 60 (1524) 48 NCAP/ 141/4 (362) 141/4 (362) 86 (2184) 86 NAWNP NOTE: For Glue Chip, Frost, and Rain, maximum short frame side is 63 118". For Reed and Narrow Reed, vertical pattern orientation maximum frame width size 63 118". For Reed and Narrow Reed, horizontal pattern orientation maximum sash height 63 118". mm (1524) (2184) (1219) (2184) INFINITY •.,.,MARVIN Glass Limits Max Glass ft2 m, 13 29/32 1.292 18 3/32 1.681 17 1.579 30 2.787 If frame height exceeds 76" or ifframe width exceeds 73 112", short side dimension offrame cannot exceed 52 118". Tempered glass may be required if the glass size is greater than 23 square feet. Please contact your local Infinity Retailer or Infinity Support at 800-372-1072 to determine available glass options on units exceeding this size. CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.2 2014-10-27 NCA I NAWN-4 19915173 Infinity Architectural Detail Manual INFINITY Infinity Casement, Awning and Picture 1-,r1MARVIN Certified Sizes and Ratings Max Max Air Tested Water Tested Design Certification Overall Width Overall Height Product to psf to psf Pressure Rating (DP) in mm in mm Infinity Casement 1.57 6.00 40.0 R-PG40-C 36 (914) 86 (2184) Infinity Casement 1.57 6.00 40.0 LC-PG40-C 31 (787) 86 (2184) Infinity Casement 1.57 6.00 40.0 LC-PG40-C 40 (1016) 60 (1524) Infinity Casement 1.57 6.00 40.0 LC-PG40-C 36 (914) 72 (1829) Infinity Casement 1.57 6.00 40.0 R-PG40-C 24 23/64 (619) 86 (2184) Infinity Casement 1.57 6.00 40.0 LC-PG40-C 21 3/8 (543) 86 (2184) Infinity Casement 1.57 6.00 40.0 LC-PG40-C 30 23164 (771) 57 (1448) (clear view hinges) Infinity Casement 1.57 6.00 40.0 R-PG40-C 30 23/64 (771) 72 (1829) (clear view hinges) Infinity Awning 1.57 6.00 40.0 LC-PG40-AP 60 (1524) 48 (1219) Infinity Casement 1.57 6.00 40.0 LC-PG40-FW 86 (2184) 86 (2184) Picture CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.1 2014-02-28 NCA I NAWN-5 19915173 Infinity Architectural Detail Manual INFINITY Infinity Casement, Awning and Picture , .. ,.,MARVIN STC/OITC Glass Values This glazing option incorporates 3.1mm/4.7mm variable thickness glass to increase STC/OITC performance and improve sound abatement. Infinity's STC/OITC upgrade includes third party ASTM ratings and reports. STC/OITC ratings for this option and for standard 3.1mm/3.1mm insulating glass are shown in the attached chart. 3.1mm -i r-3.1mm Product Type Full Frame Casement Full Frame Casement Picture Full Frame Awning STANDARD GLAZING Exterior Glazing 1/8"(3.1) 1/8" (3.1) 1/8" (3.1) 1/8"(3.1) 1/8" (3.1) 1/8" (3.1) 3.1mm -i r-4.?mm Airspace 15/32" (11.5) 13/32" (9.8) 15/32" (11.5) 13/32" (9.8) 15/32" (11.5) 13/32" (9.8) STC/OITC UPGRADE Interior Glazing 1/8"(3.1) 3/16" (4.7) 1/8" (3.1) 3/16" (4.7) 1/8" (3.1) 3/16" (4.7) STC 28 32 27 32 29 33 CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2013.1 2013-09-30 NCA I NAWN-6 OITC 25 27 24 27 25 28 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Mulling Guidelines Factory Mulled Casement/Awning Assemblies •Assemblies up to 4 units wide by 1 unit high 0 MAXIMUM ROUGH OPENING not to exceed 113" (2870) x 86 1 /2" (2197) •Assemblies up to 1 unit wide by 2 units high 0 MAXIMUM ROUGH OPENING not to exceed 73" (1854) x 96" (2438) NOTE: Field mulling beyond the above /imitations is not recommended. Rough Opening Assemblies •WIDTH: ° Frame Width= Single unit Rough Opening width MINUS 1" 0 Total Rough Opening Width = ADD all frame widths PLUS 1" •HEIGHT: ° Frame Height= Single unit Rough Opening height MINUS 1/2" 0 Total Rough Opening Height= ADD all frame heights PLUS 1/2" INFINITY '"''"MARVIN ii II CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2013.1 2013-09-30 NCA I NAWN-7 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture 1/2" Mull Reinforcement Guidelines Factory Mulled 1/2" Mull Reinforcement Casement/Awning Assemblies •Assemblies up to 4 units wide by 1 unit high 0 MAXIMUM ROUGH OPENING not to exceed 113" (2870) x 96 1/2" (2451) •Assemblies up to 1 unit wide by 2 units high 0 MAXIMUM ROUGH OPENING not to exceed 73" (1584) x 96 1/2" (2451) •Assemblies up to 2 units wide by 2 units high 0 MAXIMUM ROUGH OPENING not to exceed 97 1/2" (2477) x 96 1/2" (2451) 0 MAXIMUM ROUGH OPENING not to exceed 113" (2870) x 86 1/2" (2197) NOTE: Field mulling beyond the above limitations is not recommended. 11 Rough Opening Assemblies eWIDTH: 11 11 11 ° Frame Width = Single unit Rough Opening width MINUS 1" D D 0 Total Rough Opening Width= ADD all frame widths PLUS 1/2" for each Vertical Mull Reinforcement PLUS 1" eHEIGHT: ° Frame Height= Single unit Rough Opening height MINUS 1/2" INFINITY i.,.,.,MARVIN 0 Total Rough Opening Height= ADD all frame heights PLUS 1/2" for each Horizontal Mull Reinforcement PLUS 1/2" CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2013.1 2013-09-30 NCA I NAWN-8 19915173 Infinity Architectural Detail Manual INFINITY Infinity Casement, Awning and Picture hnMARVIN Measurement Conversions: Operable Uni1s Unit Measurementi; -Operator Casement and Awning Width Height From To Rough Opening in mm in mm MO with BMC Rough Opening -21/4 (57) -111/16 (43) Masoniy Opening Rough Opening + 1/2 (13) + 1/4 (6) OM of Frame Rough Opening + 1 (25) + 1/2 (13) Daylight Opening Rough Opening + 6 7/32 (158) + 5 23/32 (145) Frame in mm in mm Daylight Opening OM of Frame + 5 7/32 (132) + 5 7/32 (132) Sash in mm in mm OM of Frame OM of Sash -1 11/16 (43) -111/16 (43) Daylight Opening OM of Sash +317/32 (90) +317/32 (90) Glass in mm In mm Daylight Opening Glass + 11/16 (27) + 11/16 (27) Screen in mm in mm OM of Frame OM of Screen, Non-EverWood -3 7/8 (98) -4 5/16 (109) OM of Frame OM of Screen, EverWood -3 29/32 (99) -4 5/16 (109) Daylight Opening Non-EverWood Screen OM + 111/32 (34) + 29/32 (23) Daylight Opening EverWood Screen OM + 1 5/16 (33) + 29/32 (23) CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2013.2 2013-12-16 NCA I NAWN-9 19915173 Infinity Architectural Detail Manual INFINITY Infinity Casement, Awning and Picture ... ,.,MARVIN Measurement Conversions: Picture Unit Measurement -Transom and Picture Width Height From To Rough Opening in mm In mm MO with BMC Rough Opening -21/4 (57) -1 11/16 (43) Masonry Opening Rough Opening + 1/2 (13) + 1/4 (6) OM of Frame Rough Opening + 1 (25) + 1/2 (13) Daylight Opening Rough Opening +6 7/32 (158) + 5 23/32 (145) Frame In mm In mm Daylight Opening OM of Frame + 5 7/32 (132) + 5 7/32 (132) Sash in mm In mm OM of Frame OM of Sash -111/16 (43) -1 11/16 (43) Daylight Opening OM of Sash + 3 17/32 (90) + 317/32 (90) Glass In mm In mm Daylight Opening Glass + 11/16 (27) + 1 1116 (27) CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2013.2 2013-12-16 NCA I NAWN-10 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Measurement Conversions: Egress -Easy Wash™ Minimum Value for Net Clear Opening 20in 24in 5.7 ft2 Egress Conversions Easy Wash™ Egress Minimum Opening and Conversions from Frame Size Desired Dimension Egress opening width, in Egress opening height, in Egress opening area, ft2 Clear Opening Height I Formula = NGA frame OM width -10.352 =NGA frame OM height -4.816 = ((Egress opening width, in) x (Egress opening height, in))/ 144 Easy Wash TM Hinge CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.1 2014-01-27 NCA I NAWN-11 INFINITY hr.MARVIN 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Measurement Conversions: Egress -Clear View Minimum Value for Net Clear Opening 20in 24 in 5.7112 Egress Conversions Clear View™ Egress Minimum Opening and Conversions from Frame Size Desired Dimension Egress opening width, in Egress opening height, in Egress opening area, 112 Clear Opening Height I Formula = NGA frame OM width -5.967 =NGA frame OM height -4.816 = ((Egress opening width, in) x (Egress opening height, in))/ 144 II Jl !,- Clear ~ -Opening --I 11 Width I I ~~ Clear View TM Hinge CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.1 2014-01-27 NCA I NAWN-12 INFINITY ,.,.,MARVIN 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Section Details: Operating and Picture Scale: 3" = 1' O" f--31/4" I -(83) -1 25132· L 11/16" I , (17) J__ (55) l __ L I I I I I _L -, I I I 1 5/16" (33) -r 1 5/16" (33) ;;/16"_y-- (17) ---.- Head Jamb and Sill I-31/4" I I -(83) -1 11115· __ I 25/32" 1-- (17~ (55) I ' ---,- 21/4" (57) _ _J 11/1~~-­ (17) Head Jamb and Sill 1 11/16" (17) Jambs Jambs INFINITY 11/16" (17) CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.1 2014-01-27 NCA I NAWN-13 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Section Details: Casing Options Scale: 3" = 1' O" 11114" 1_ -1 (32) I l_i 111132" (34) 19132" ~r (15) Brick Mould Casing INFINITY CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.1 2014-01-27 NCA I NAWN-14 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Section Details: Mullions Scale: 3" = 1' O" Vertical Mullion-Operator/Picture Horizontal Mullion-Operator/Picture Vertical Mullion-Operator/Operator INFINITY CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver2014.1 2014-01-27 NCA/NAWN-15 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Section Details: 1/2" Mull Reinforcement Scale: 3" = 1' O" 1/2" Mull Reinforcement Picture/Operator NCAP,NAWNP/NCA,NAWN 1/2" Mull Reinforcement NCA,NAWN/NDGRT,NPDG 1/2" Mull Reinforcement Operator/Picture NCA,NAWN/NCAP,NAWNP L 1_11/16" I --t (27) 5" r---(127)----i 1/2" Mull Reinforcement NCA,NAWN/NPDG INFINITY '·u·,MARVIN CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver2014.1 2014-01-27 NCA/NAWN-16 19915173 Infinity Architectural Detail Manual Infinity Casement, Awning and Picture Interior Frame Accessories Scale: 3" = 1' O" \-1 _,_ w Material / Jt Jamb Extension ,,,, n Adaptor V1192 5/8" Sheetrock Receiver .·~Interior / Frame Cover I I V1670 Interior Trim INFINITY ··~MARVIN CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm Ver 2014.1 2014-01-27 NCA I NAWN-17 19915173 Infinity Architectural Detail Manual ;g 0 ,, 0 VI VI 0 c :r "" r "" < > =I ~ N ,, "' !fi 0 "" 0 "" > VI --< "" r "" < > =I ~ KORCB RESIDENCE REMODEL & ADDITION 4284 Columbine Drive Unit D VAIL, COLORADO N Iii ~ ;g i ;g iO i!'ij -. " ~~ ~~ "' "' 0 0 z :!!\ 0 "' Vl _, :i: _, "' "' r f;; gJ "' < < > > =i =i 0 0 z z Q;J !""""°" II ._K_O_R_C_H_RE_~_!~_E_c~_'u_~_~n_~_n_ri~-·-~-~_:_L_&_AD_D_IT_l_O_N___. ._ __ __,__,__li_i:_~~-i\'_.f,..· ~ .. "--~---" Erl VAIL, COLORADO _