HomeMy WebLinkAboutwindow specs_5 (2).pdfMarvin Order Management Performance Summary Report Date/Time: 7/20/2016 5:14 PM Job/Project Name: POLIDORI, RANDIE/ 07/12/16 Sales Rep: MIKE GRAVINA PK Version: 0002.09.00 Quote/Order Number: CVHZEVB Organization Name: GRAVINA WINDOW CENTER Line Mark Unit Unit ID Brand Product Size U-Factor SHGC VLT CR 1 2ND SOUTH LOFT Al Infinity Casement Picture 29 5/B x 70 5/B 0.30 0.23 0.53 55 2ND NORTH LOFT Al Infinity Casement Picture 29 5/B x 70 5/B 0.30 0.23 0.53 55 3RD WEST LOFT Al Infinity Awning 42 5/B x 22 5/B 0.31 0.20 0.46 54 4 3RD WEST LOFT Al Infinity Awning 42 5/B x 22 5/B 0.31 0.20 0.46 54 3RD WEST LOFT Infinity P4 Direct Glaze 39X73 XSS 0.31 0.24 O.SS 57 3RD WEST LOFT Infinity P4 Direct Glaze 39 X 73 X SS 0.31 0.24 o.ss 57 3RD WEST DINING ROOM Infinity P4 Direct Glaze 72X60X24 0.31 0.24 o.ss 57 8 2ND WEST DINING ROOM Al Infinity Rectangle 72 X42 0.31 0.24 0.55 57 9 WEST DINING ROOM Al Infinity Infinity Assembly 73 1/4 x S2 1/2 0.30 0.20 0.46 S6 9 WEST DINING ROOM A2 Infinity Infinity Assembly 0.30 0.23 O.S3 55 WEST DINING ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 S6 10 SOUTH DINING ROOM Al Infinity Infinity Assembly 73 1/4 x 52 1/2 0.30 0.20 0.46 56 10 SOUTH DINING ROOM A2 Infinity Infinity Assembly 0.30 0.23 O.S3 55 10 SOUTH DINING ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 56 11 2ND SOUTH DINING ROOM Al Infinity Rectangle 7S X461/2 0.30 0.24 O.S5 57 12 2ND WEST NOOK Al Infinity Casement 30 7/B x 54 3/4 0.30 0.20 0.46 56 13 3RD WEST NOOK Infinity P4 Direct Glaze 2B x 104 x 90 14 2ND SOUTH FAMILY ROOM Al Infinity Infinity Assembly 73 1/4 x 54 3/4 0.30 0.20 0.46 S6 14 2ND SOUTH FAMILY ROOM A2 Infinity Infinity Assembly 0.30 0.23 O.S3 SS 14 2ND SOUTH FAMILY ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 S6 IS 3RD SOUTH FAMILY ROOM Infinity P4 Direct Glaze 74X82X4B 16 2ND SOUTH FAMILY ROOM Al Infinity Infinity Assembly 73 1/4 x 54 3/4 0.30 0.20 0.46 56 16 2ND SOUTH FAMILY ROOM A2 Infinity Infinity Assembly 0.30 0.23 0.53 55 16 2ND SOUTH FAMILY ROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 56 17 3RD SOUTH FAMILY ROOM Infinity P4 Direct Glaze 74 x 82 x 48 18 BASEMENT SOUTH BEDROOM Al Infinity Infinity Assembly 73 1/4 x 42 3/4 0.30 0.20 0.46 56 IS BASEMENT SOUTH BEDROOM A2 Infinity Infinity Assembly 0.30 0.23 0.53 SS IB BASEMENT SOUTH BEDROOM A3 Infinity Infinity Assembly 0.30 0.20 0.46 56 19 WEST FAMILY ROOM Al Infinity Casement 30 S/8 X 54 3/4 0.30 0.20 0.46 56 20 2ND WEST FAMILY ROOM Infinity P4 Direct Glaze 29X46X28 0.31 0.24 O.S5 57 lill!!!m. Certified Product Directory (CPD) Number - a unique number used by the NFRC to organize product listing of certified products. Condensation Resistance (CR): Measures the ability of a product to resist the formation of condensation on the interior surface of that product. The higher the CR rating the better it resists forming condensation. ENERGY STAR is a program of the U.S. Environmental Protection Agency designed to recognize products that meet strict energy efficiency guidelines. Learn more about ENERGY STAR. Solar Heat Gain Coefficient (SHGC) measures how well a product blocks heat from the sun. In warm climates, the lower the number, the better. Here you want to keep heat out by choosing windows that reflect solar radiation. Less heat coming into the home means lower air-conditioning costs and a reduced carbon footprint. In cold regions, your windows can also help you take advantage of solar radiation, which is free heat that eases the workload of your furnace or other energy-powered heat source. A higher solar heat gain coefficient means a window will allow more heat to pass through. U-Factor: (Btu/hr.-sq. ft. -•f.) A measurement of the amount of heat flow through a product. The lower the U-factor, the greater the resistance to heat flow and better its insulating value. The National Fenestration Rating Council (NFRC) has developed and operates a uniform national rating system for the energy performance of fenestration products, including windows and doors. For additional information regarding this rating system, see www.nfrc.org/WindowRiltings. NFRC energy ratings and values may vary depending on the exact configuration of glass thickness used on the unit. This data may change over time due to ongoing product changes or updated test results or requirements.
Infinity Casement and Awning
Unit Features.......................................................................................................................................................... 1
Lite Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Minimum and Maximum Guidelines....................................................................................................................... 4
Certified Sizes and Ratings.................................................................................................................................... 5
STC/OITC Glass Values . . . .. . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . 6
Mulling Guidelines.................................................................................................................................................. 7
1/2" Mull Reinforcement Guidelines....................................................................................................................... 8
Measurement Conversions: Operable Units . . . . . . . . .. . . .. . . . . . . . . . .. . . . . . . . . . .. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . 9
Measurement Conversions: Picture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Measurement Conversions: Egress -Easy Wash™ . . . . . . . . . . . . .. . . . . . . . . .. . . . . . .. . . . . .. . . . . . .. . . . . .. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . .. .. . . . . . . . . 11
Measurement Conversions: Egress -Clear View................................................................................................... 12
Section Details: Operating and Picture . . . .. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Section Details: Casing Options............................................................................................................................. 14
Section Details: Mullions . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . .. .. . . . . . . . . . . . . . . . . . . . . . .. . . . . .. . . 15
Section Details: 1/2" Mull Reinforcement............................................................................................................... 16
Interior Frame Accessories.................................................................................................................................... 17
CHECK MARVIN ONLINE DOCS FOR LATEST. VERSION Printed On: Jul 14, 2016, 3:41 pm I 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Unit Features
Infinity Casement: NCA
Infinity Awning: NAWN
Infinity Casement Picture: NCAP
Ultrex® Pultruded Fiberglass Frame:
•Frame thickness: 1 5/16" (33)
•Frame depth: 2 5/32" (55)
• Exterior colors: Stone White, Sierra, Cashmere, Pebble Gray, Bahama Brown, Bronze
•Interior colors: Stone White, Sierra, EverWood™
Ultrex® Pultruded Fiberglass Sash:
• Sash thickness: 1 3/8" (35)
• Operating sash is removable for cleaning
• Sash are replaceable but cannot be re-glazed
• Exterior colors: Stone White, Sierra, Cashmere, Pebble Gray, Bahama Brown, Bronze
• Interior colors: Stone White, Sierra, EverWood™
Casement Hardware:
• Lock and keeper:
INFINITY
h···MARVIN
0 Multi-point locking mechanism that is actuated from a single point of operation. Lock mechanisms are concealed with only the
actuator handle and escutcheon being visible to the interior. Keepers are mounted to the interior face of the sash and interlocks
within concealed lock when actuated.
•Operator:
° Concealed hinges with stainless steel tracks
0 Snubber: pulls the sash tight to the frame and provides positive engagement to secure the sash under structural load
conditions
0 Dual arm roto-gear operator on units 24 3/8" (619) wide frame size and over
0 Split-arm rote-gear operator used on units less than 24 3/8" (619) wide
•Handle:
0 Die-cast folding crank handle
•Factory installed Window Opening Control Device (WOCD):
0 Minimum Frame OSM 18 5/32" (461) x 17 3/8" (441)
0 Maximum Frame OSM 40" (1016) x 60" (1524) or 36" (914) x 86" (2184)
0 WOCD locking assembly:
• Factory installed
•Die-cast
• Color: White, Satin Taupe, Sierra
0 WOCD tether assembly: factory installed, glass filled nylon
• Color: E-Gard color match
Awning Hardware:
• Lock and keeper:
° Cam lock and stainless steel keeper system
•Operator:
° Concealed hinges and steel tracks
° Factory installed rote-gear operator
•Handle:
0 Die-cast folding crank handle
• Sash Limiter:
° Factory installed or field applied
Weather Strip:
•Frame:
0 Extruded foam bulb weather strip that runs around the perimeter of the frame sealing against the interior face of the sash
• Color: black
.sash:
0 Extruded thermoplastic bulb that attaches to a kerf around the top, bottom and sides of the sash; sealing against the inner
perimeter of the frame
• Color: beige or black
• Black is for Bahama Brown and Bronze exterior units
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2015.1 2015-08-31 NCA I NAWN-1 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Unit Features:
Insect Screens:
•Full screen
• Roll formed aluminum frame
• Mitered corner key; injection molded, color matched to screen
• Color: Stone White, Satin Taupe, Sierra, EverWood ™
•Standard screen mesh material: charcoal fiberglass
0 Optional screen mesh material: high transparency
Glass:
• Glazing seal: silicone bedding on interior and exterior
• Standard glass: Low E2 with Argon or air
INFINITY
lv·oMARVIN
•Optional glazing available: Low E1 with Argon or air, Low E3 with Argon or air, or Low E3/ERS with Argon or air, clear, tints,
tempered, obscure
•Decorative glass options include Glue Chip, Rain, Reed, Narrow Reed, or Frost
•Decorative glass is not available with Low E1, Low E3/ERS, or STC/OITC
•Rain, Reed and Narrow Reed not available with SDL
•SOL available on Frost, annealed or tempered glass
• SDL available on Glue Chip, tempered glass required
• Insulating glass will be altitude adjusted with capillary tubes for higher elevations
•Argon gas is not available for elevations that require capillary tubes
Simulated Divided Lites (SOL):
• 718" (22) or 1 1/8" (29) SDL bar (interior and exterior)
• 2 11/32" (30) simulated rail (interior and exterior)
• Exterior color: matched to unit exterior
• Interior color: matched to interior -ABS material
• Pattern: equal rectangular, cottage, prairie, check rail
Gilles-Between-the-Glass (GBG):
e 11/16" (18) or 1" (25) contoured aluminum bar
• Exterior: color matched to unit exterior
•The exterior GBG color is designed to best match the unit exterior color when used with Low E glass. The use of different types
of glazing options may alter the exterior GBG color appearance.
• Interior color: White, Satin Taupe, Sierra, Bronze
• Pattern: equal rectangular, cottage, prairie, check rail
NOTE: GBG may not be available or may require tempered glass if the glass size is greater than 16 square feet or if the short side
dimension is greater than 48". Please contact your local Infinity Retailer or Infinity Support at 800-372-1072 to determine if
GBG is available for glass sizes exceeding these dimensions.
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2015.1 2015-06-29 NCA I NAWN-2 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Lite Options
Insulating Glass
-1 L--11/16" ' (18) ~----=='---l~c~ ~ ~c;~=~#~f 't~ [:;_ _ __ , ==='
11 /16" Insulating Glass
GBG
1" Insulating Glass
GBG
0 \
0
Insulating Glass
SOL Simulated Rail
w/ spacer bar
Insulating Glass
7/8" SOL w/ spacer bar
Insulating Glass
1 1/8" SOL w/ spacer bar
INFINITY
1-c,.,MARYIN
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2015.1 2015-06-29 NCA I NAWN-3 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Minimum and Maximum Guidelines
Minimum and Maximum Guidelines
Frame Size
UnitType Min Width Min Height Max Width Max Height
in mm in mm in mm in
161/4 (413) 17 3/8 (441) 40 (1016) 60
NGA
161/4 (413) 17 3/8 (441) 36 (914) 86
NAWN 171/2 (445) 17 3/8 (441) 60 (1524) 48
NCAP/ 141/4 (362) 141/4 (362) 86 (2184) 86 NAWNP
NOTE: For Glue Chip, Frost, and Rain, maximum short frame side is 63 118".
For Reed and Narrow Reed, vertical pattern orientation maximum frame width size 63 118".
For Reed and Narrow Reed, horizontal pattern orientation maximum sash height 63 118".
mm
(1524)
(2184)
(1219)
(2184)
INFINITY
•.,.,MARVIN
Glass Limits
Max Glass
ft2 m,
13 29/32 1.292
18 3/32 1.681
17 1.579
30 2.787
If frame height exceeds 76" or ifframe width exceeds 73 112", short side dimension offrame cannot exceed 52 118".
Tempered glass may be required if the glass size is greater than 23 square feet. Please contact your local Infinity Retailer or
Infinity Support at 800-372-1072 to determine available glass options on units exceeding this size.
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.2 2014-10-27 NCA I NAWN-4 19915173
Infinity Architectural Detail Manual
INFINITY
Infinity Casement, Awning and Picture 1-,r1MARVIN
Certified Sizes and Ratings
Max Max
Air Tested Water Tested Design Certification Overall Width Overall Height Product to psf to psf Pressure Rating (DP)
in mm in mm
Infinity Casement 1.57 6.00 40.0 R-PG40-C 36 (914) 86 (2184)
Infinity Casement 1.57 6.00 40.0 LC-PG40-C 31 (787) 86 (2184)
Infinity Casement 1.57 6.00 40.0 LC-PG40-C 40 (1016) 60 (1524)
Infinity Casement 1.57 6.00 40.0 LC-PG40-C 36 (914) 72 (1829)
Infinity Casement 1.57 6.00 40.0 R-PG40-C 24 23/64 (619) 86 (2184)
Infinity Casement 1.57 6.00 40.0 LC-PG40-C 21 3/8 (543) 86 (2184)
Infinity Casement 1.57 6.00 40.0 LC-PG40-C 30 23164 (771) 57 (1448) (clear view hinges)
Infinity Casement 1.57 6.00 40.0 R-PG40-C 30 23/64 (771) 72 (1829) (clear view hinges)
Infinity Awning 1.57 6.00 40.0 LC-PG40-AP 60 (1524) 48 (1219)
Infinity Casement 1.57 6.00 40.0 LC-PG40-FW 86 (2184) 86 (2184) Picture
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.1 2014-02-28 NCA I NAWN-5 19915173
Infinity Architectural Detail Manual
INFINITY
Infinity Casement, Awning and Picture , .. ,.,MARVIN
STC/OITC Glass Values
This glazing option incorporates 3.1mm/4.7mm variable thickness glass to increase STC/OITC performance and improve sound
abatement. Infinity's STC/OITC upgrade includes third party ASTM ratings and reports. STC/OITC ratings for this option and for
standard 3.1mm/3.1mm insulating glass are shown in the attached chart.
3.1mm -i r-3.1mm
Product Type
Full Frame Casement
Full Frame
Casement Picture
Full Frame Awning
STANDARD
GLAZING
Exterior Glazing
1/8"(3.1)
1/8" (3.1)
1/8" (3.1)
1/8"(3.1)
1/8" (3.1)
1/8" (3.1)
3.1mm -i r-4.?mm
Airspace
15/32" (11.5)
13/32" (9.8)
15/32" (11.5)
13/32" (9.8)
15/32" (11.5)
13/32" (9.8)
STC/OITC
UPGRADE
Interior Glazing
1/8"(3.1)
3/16" (4.7)
1/8" (3.1)
3/16" (4.7)
1/8" (3.1)
3/16" (4.7)
STC
28
32
27
32
29
33
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2013.1 2013-09-30 NCA I NAWN-6
OITC
25
27
24
27
25
28
19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Mulling Guidelines
Factory Mulled Casement/Awning Assemblies
•Assemblies up to 4 units wide by 1 unit high
0 MAXIMUM ROUGH OPENING not to exceed 113" (2870) x 86 1 /2" (2197)
•Assemblies up to 1 unit wide by 2 units high
0 MAXIMUM ROUGH OPENING not to exceed 73" (1854) x 96" (2438)
NOTE: Field mulling beyond the above /imitations is not recommended.
Rough Opening Assemblies
•WIDTH:
° Frame Width= Single unit Rough Opening width MINUS 1"
0 Total Rough Opening Width = ADD all frame widths PLUS 1"
•HEIGHT:
° Frame Height= Single unit Rough Opening height MINUS 1/2"
0 Total Rough Opening Height= ADD all frame heights PLUS 1/2"
INFINITY
'"''"MARVIN
ii II
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2013.1 2013-09-30 NCA I NAWN-7 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
1/2" Mull Reinforcement Guidelines
Factory Mulled 1/2" Mull Reinforcement Casement/Awning Assemblies
•Assemblies up to 4 units wide by 1 unit high
0 MAXIMUM ROUGH OPENING not to exceed 113" (2870) x 96 1/2" (2451)
•Assemblies up to 1 unit wide by 2 units high
0 MAXIMUM ROUGH OPENING not to exceed 73" (1584) x 96 1/2" (2451)
•Assemblies up to 2 units wide by 2 units high
0 MAXIMUM ROUGH OPENING not to exceed 97 1/2" (2477) x 96 1/2" (2451)
0 MAXIMUM ROUGH OPENING not to exceed 113" (2870) x 86 1/2" (2197)
NOTE: Field mulling beyond the above limitations is not recommended.
11
Rough Opening Assemblies
eWIDTH:
11
11 11
° Frame Width = Single unit Rough Opening width MINUS 1"
D D
0 Total Rough Opening Width= ADD all frame widths PLUS 1/2" for each Vertical Mull Reinforcement PLUS 1"
eHEIGHT:
° Frame Height= Single unit Rough Opening height MINUS 1/2"
INFINITY
i.,.,.,MARVIN
0 Total Rough Opening Height= ADD all frame heights PLUS 1/2" for each Horizontal Mull Reinforcement PLUS 1/2"
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2013.1 2013-09-30 NCA I NAWN-8 19915173
Infinity Architectural Detail Manual
INFINITY
Infinity Casement, Awning and Picture hnMARVIN
Measurement Conversions: Operable Uni1s
Unit Measurementi; -Operator Casement and Awning
Width Height
From To
Rough Opening in mm in mm
MO with BMC Rough Opening -21/4 (57) -111/16 (43)
Masoniy Opening Rough Opening + 1/2 (13) + 1/4 (6)
OM of Frame Rough Opening + 1 (25) + 1/2 (13)
Daylight Opening Rough Opening + 6 7/32 (158) + 5 23/32 (145)
Frame in mm in mm
Daylight Opening OM of Frame + 5 7/32 (132) + 5 7/32 (132)
Sash in mm in mm
OM of Frame OM of Sash -1 11/16 (43) -111/16 (43)
Daylight Opening OM of Sash +317/32 (90) +317/32 (90)
Glass in mm In mm
Daylight Opening Glass + 11/16 (27) + 11/16 (27)
Screen in mm in mm
OM of Frame OM of Screen, Non-EverWood -3 7/8 (98) -4 5/16 (109)
OM of Frame OM of Screen, EverWood -3 29/32 (99) -4 5/16 (109)
Daylight Opening Non-EverWood Screen OM + 111/32 (34) + 29/32 (23)
Daylight Opening EverWood Screen OM + 1 5/16 (33) + 29/32 (23)
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2013.2 2013-12-16 NCA I NAWN-9 19915173
Infinity Architectural Detail Manual
INFINITY
Infinity Casement, Awning and Picture ... ,.,MARVIN
Measurement Conversions: Picture
Unit Measurement -Transom and Picture
Width Height
From To
Rough Opening in mm In mm
MO with BMC Rough Opening -21/4 (57) -1 11/16 (43)
Masonry Opening Rough Opening + 1/2 (13) + 1/4 (6)
OM of Frame Rough Opening + 1 (25) + 1/2 (13)
Daylight Opening Rough Opening +6 7/32 (158) + 5 23/32 (145)
Frame In mm In mm
Daylight Opening OM of Frame + 5 7/32 (132) + 5 7/32 (132)
Sash in mm In mm
OM of Frame OM of Sash -111/16 (43) -1 11/16 (43)
Daylight Opening OM of Sash + 3 17/32 (90) + 317/32 (90)
Glass In mm In mm
Daylight Opening Glass + 11/16 (27) + 1 1116 (27)
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2013.2 2013-12-16 NCA I NAWN-10 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Measurement Conversions: Egress -Easy Wash™
Minimum Value for
Net Clear Opening
20in
24in
5.7 ft2
Egress Conversions
Easy Wash™ Egress Minimum Opening and Conversions from Frame Size
Desired Dimension
Egress opening width, in
Egress opening height, in
Egress opening area, ft2
Clear
Opening
Height
I
Formula
= NGA frame OM width -10.352
=NGA frame OM height -4.816
= ((Egress opening width, in) x (Egress opening height, in))/ 144
Easy Wash TM Hinge
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.1 2014-01-27 NCA I NAWN-11
INFINITY
hr.MARVIN
19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Measurement Conversions: Egress -Clear View
Minimum Value for
Net Clear Opening
20in
24 in
5.7112
Egress Conversions
Clear View™ Egress Minimum Opening and Conversions from Frame Size
Desired Dimension
Egress opening width, in
Egress opening height, in
Egress opening area, 112
Clear
Opening
Height
I
Formula
= NGA frame OM width -5.967
=NGA frame OM height -4.816
= ((Egress opening width, in) x (Egress opening height, in))/ 144
II
Jl
!,-
Clear ~ -Opening --I 11
Width I I
~~
Clear View TM Hinge
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.1 2014-01-27 NCA I NAWN-12
INFINITY
,.,.,MARVIN
19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Section Details: Operating and Picture
Scale: 3" = 1' O"
f--31/4"
I -(83) -1
25132· L 11/16" I ,
(17) J__ (55) l __ L
I
I
I
I
I
_L
-,
I
I
I
1 5/16"
(33) -r
1 5/16"
(33)
;;/16"_y--
(17)
---.-
Head Jamb and Sill
I-31/4" I I -(83) -1
11115· __ I 25/32" 1--
(17~ (55) I
' ---,-
21/4"
(57)
_ _J
11/1~~-
(17)
Head Jamb and Sill
1
11/16"
(17)
Jambs
Jambs
INFINITY
11/16"
(17)
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.1 2014-01-27 NCA I NAWN-13 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Section Details: Casing Options
Scale: 3" = 1' O"
11114" 1_ -1 (32) I
l_i
111132"
(34)
19132" ~r
(15)
Brick Mould Casing
INFINITY
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.1 2014-01-27 NCA I NAWN-14 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Section Details: Mullions
Scale: 3" = 1' O"
Vertical
Mullion-Operator/Picture
Horizontal
Mullion-Operator/Picture
Vertical
Mullion-Operator/Operator
INFINITY
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver2014.1 2014-01-27 NCA/NAWN-15 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Section Details: 1/2" Mull Reinforcement
Scale: 3" = 1' O"
1/2" Mull Reinforcement
Picture/Operator
NCAP,NAWNP/NCA,NAWN
1/2" Mull
Reinforcement
NCA,NAWN/NDGRT,NPDG
1/2" Mull Reinforcement
Operator/Picture
NCA,NAWN/NCAP,NAWNP
L 1_11/16"
I --t (27)
5" r---(127)----i
1/2" Mull
Reinforcement
NCA,NAWN/NPDG
INFINITY
'·u·,MARVIN
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver2014.1 2014-01-27 NCA/NAWN-16 19915173
Infinity Architectural Detail Manual
Infinity Casement, Awning and Picture
Interior Frame Accessories
Scale: 3" = 1' O"
\-1 _,_ w Material
/ Jt Jamb Extension ,,,, n Adaptor
V1192
5/8" Sheetrock
Receiver
.·~Interior
/ Frame Cover
I
I
V1670
Interior Trim
INFINITY
··~MARVIN
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On: Jul 14, 2016, 3:41 pm
Ver 2014.1 2014-01-27 NCA I NAWN-17 19915173
Infinity Architectural Detail Manual
;g
0 ,,
0 VI
VI 0 c :r
"" r "" < > =I ~
N ,,
"' !fi 0
"" 0
"" > VI --<
"" r "" < > =I ~
KORCB RESIDENCE REMODEL & ADDITION
4284 Columbine Drive Unit D
VAIL, COLORADO
N Iii
~ ;g i ;g iO i!'ij -. " ~~ ~~ "' "' 0 0
z :!!\ 0 "' Vl _,
:i:
_,
"' "' r f;; gJ "' < < > > =i =i 0 0 z z
Q;J !""""°" II ._K_O_R_C_H_RE_~_!~_E_c~_'u_~_~n_~_n_ri~-·-~-~_:_L_&_AD_D_IT_l_O_N___. ._ __ __,__,__li_i:_~~-i\'_.f,..· ~ .. "--~---" Erl VAIL, COLORADO _