75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL A18-0019 Vail,CO 81657 Issued: 04/24/2018 TOWN OF VAIL , Office:970.479.2139 InspectionLine:970.479.2149 Property Information Address: 1853 LIONSRIDGE LP B (2103122020278)(210312202027) Unit#: B ParcelNumber: 210312202027 LegalDescription: Subdivision:LIONSRIDGE FIL3 Block:3 Lot:3 PARCELB BK-0583PG-0946QCD 06-24-92R708123 QCD 09-02-99R765095QCD 08-15-01 Contacts ContactType: Applicant Full Name: Brad Wolniak Address: 210 EdwardsVillage BlvdA108 Edwards,CO 81632 Phone: 9709268788 ContactType: PropertyOwner Full Name: RAYMOND H.GOETZREVOCABLE TRUST, RAYMOND H.GOETZTRUSTEE Address: Phone: None Contractor Contractor Type: Alarm Company: SuperiorAlarm&Electronics, Inc State License#: Phone: 970-926-8788 Projectlnformation ProjectName: GoetzResidence2017 ProjectDescription: Install a monitored firealarmsystem Fees Paid Account#:001-0000.31111.00 -Fire AlarmPermitFee Fee Amount: $161.25 Account#:001-0000.31123.00 Fire AlarmReviewFee Fee Amount: $288.00 TotalPaid: $449.25 Conditions Issued By:TownofV ailFireand EmergencyServices Department NOTICE:Byissuance ofthis Permittheapplicantagreesto complyto all Titlesof the Townof Vail Code and all applicableStateand Federal law.Failureto do so will void this Permitand the applicantshallforfeitall applicablefees. Concord 4 Powerful, expandable security with Learn Mode technology OVERVIEW Concord"4 is a full-featured securitysystem forresidential and Effortless programming commercial intrusion as well as residential fire detection that Conduct quickand easyon-site programming with alphanumeric complies with false alarm standards.Easyto install and simple to touchpads and a menu-driven text interface with shortcut menu use,Concord's modulardesign and advanced software provide numbers.A quick programming menu makes it even easierto install outstanding system flexibilityto meet the needs ofvirtuallyany smaller,basic systems.Foroff-site programming,use Enterprise® residential orcommercial securityapplication. downloadersoftware(version 3.1 and later). High standards The panel comes standard with eight hardwire zone inputs,including STANDARD FEATURES a two-wire smoke detectorloo pthat can handle up to 20 detectors. A built-in RF receiver with 96-zone capacity(600-1021-95R only) •6 partitions and 8 built-in hardwire zones-96 zones maximum provides instant compatibility with the complete line oflnterlogixLearn as eitherhardwire,wireless,o rcombination Mode sensors.Twoprogrammable outputs can be set up to activate •96 wireless zones standard onboard(600-1021-95Ronly) external devices during an alarm orothersystem event. •2 onboard programmable outputs •Compatible with all Interlogixcrystal and SAW Learn Mode sensors Easyexpansion •SIACP-01 False Alarm Reduction Standard compliant Expand Concord's capabilities byadding SuperBus®2000 8Z Input •2 and 4-wire smoke detectorcompatibility Modules foreight additional zones permodule,orSuperBus 2000 •Panel auxiliarypowerprovides 1 amp 4-RelayOutput Modules to add fourmore output points.SnapCardsM .guilt in 12 watt siren driver also add to system zone inputs and outputs.Each card(one per panel)connects easilyto the panel circuit board inside the cabinet for a clutter-free,professional installation.Increase RF coverage area by ADDITIONAL FEATURES adding up tofourSuperBus 2000 RF receivers orSuperBus 2000 RF transceivers.Each receiver supports all 96 zones. •230 user-programmable access codes with programmable autho rityievels Expand the system even furtherwith a Phone InterfaceNoice •Latchkey numeric paging with optional keychain touchpad activation Module foron-and off-site system control using touch-tone phones. •Audio verification in partition 1 with VOXmode(requires The module includes a speakeroutput that provides on-site voice Interrogator®200) status and alarm messages. •250-event historybufferviewable from any alphanumeric keypad, Adding a SuperBus 2000 EnergySaverModule lets users control downloaderorautomation device heating and air conditioning.With the addition ofa Z Wave®enabled •Keyswitch arming using a hardwire orwireless zone CellularModule,with service from Alarm.com®control ofautomated •Programmable on-site using alphanumeric touchpads oroff-site lights,doorlocks,thermostats and more is available using alm ost using Enterprise anyWeb enabled device. •Programmable macrokeys simplifyuserinteraction with single- button system comm ands Increase powercapabilityforsystem peripherals with a •Time and status displayed on all touchpads SuperBus 2000 two-amp PowerSupplyModule with battery •16 schedules available forscheduled lighting and outputs backup.The module provides two amps at 12VDC. interlogix.com Concord 4 NorthAmerica T85 Australia Europe32- - Latin America T 855-286-8889 852-2907-8108 T 61-3-9239-1200 T 32-2-725-11-20 T 561-998-6114 Powerful, expandable security with Learn Mode technology Specifications Ordering Information Powersupply Concord 4 panels Required transformer Class II,16.5 VAC,40 VA,60 Hz 600-1021-95R Concord 4 RF panel Backupbattery 12VDC,4.5 Ah or7 Ah rechargeable,sealed, 600 1040 Concord 4 Commercial(does not include lead-acid 96-zone wireless receiver) Batterybackup tim e 24 hours(when fully charged,with appropriate Expansion options external load) 60-620-01 SuperBusa 2000 energy-saver module(ESM) Batterytest 15 minutes under load every24 hours 60-756 Comboinput/output SnapCard" (every4 hours forUL installations) Transformer fuse Non-replaceable fuse 60-757 8Z hardwire input SnapCard Panel auxiliary Current-limited,1.0 A max.@ 12VDC 60-758 4-output SnapCard 60-770 SuperBus 2000 4-output module voltage output 60-774 SuperBus 2000 8Z input module Communication formats 60-783-02 SuperBus 2000 automatiormodule Dialing DTMForpulse with integrated line seizure relay SuperBus 2000 phone interface and voice Formats supported SIA Digital II(300 bps)orContact ID 60-777-01 module Capabilities 3 central station phone numbers and 5 pager 60 821 95 SuperBus 2000 commercial transceiver module phone numbers (compatible with crystal sensors and touchpads) Inputs 600-1053-3 SuperBus 2000 GSM module(2.5G) 96 max.hardwire orwireless;8 hardwire zones 600-1053-4 SuperBus 2000 GSM(3G)or CDMA module Input zones built in,96 zone wireless capacitybuilt in 600-1019 SuperBus 2000 2.0 A power supply module (600-1021-95R only) 600-1025-01-95R SuperBus 2000 transceiver module Databus format SuperBus 2000 with auto-enrolling capability Touchpad options Databus capacity Up to 16 devices 60-597-95 HiTech handheld touchpad Outputs 600-1064-95R Micro key fob,4-button SAW 12VDC,1.0A 60-746-01/60-803-04 SuperBus 2000 2x16 and 2x20 LCD OUT1/+12V(output 1) alphanumeric touchpads (max.combined with auxiliarypoweroutput) SuperBus 2000 2x20 vacuum fluorescent OUT2/OC(output 2) Open-collector,300 mA max 60-804-04 display alphanumeric touchpad Auxiliar owerout ut Regulated,currenfimited,self-resetting 12VDC: p 1.0 A(max.combined with output 1) 60-820 SuperBus 2000 fixed display LCD touchpad 60-983 ATP1000 alphanumeric touchpad Environmental 32 to 120°F(0 to 49°C);up to 140°F(60°C) 60-985/60-984 ATP2100 and ATP2600 alphanumeric Operating temperature touchpads under temporary conditions 600-1020 FTP1000 fixed English touchpad Storage temperature -30 to 140°F(-34 to 60°C) Relative hum idity 90%max.,noncondensing Transformer options 16.5 V,40 VA standard transformer,UL listed for Physical 600-1023 U.S.applications Dimensions(HxWxD) 14.0 x 12.0 x 3.0 in.(356 x 305 x 76 mm) 16.5 V,40 VA standard transformer,cUL/CSA Weight 5 lb.,10 oz.(2.5 kg) 600-1023-CN listed for Canadian applications Chassis material 0.048 in.(1.2 mm)16gauge steel,punched 16.5 V,40 VA power line carrier transformer,UL and formed 600-1024 listed for U.S.applications Color Beige Regulatory FCC Parts 15 and 68 UL985,UL 1023,UL 1635 UL 1610(600-1040 panel only),cUL SIACP-01 2000 False Alarm Prevention interlogix interlogix.com Specifications subject to change without notice. ©2013 Interlogix. All rights reserved. Interlogix is part of UTC Clim ate,Controls&Security, a unit of United Technologies Corporation. 301-3619 2013/08 (73444) • ' interlogix A UTC Fire&Security Company ATP1000 Touchpad/Display Installation Instructions • Table 2 describes the maximum wire lengths allowed Product summary between the touchpad and the panel. The ATP1000 lets you control all programming and operation Table 1. Touchpad power usage of compatible security systems(see the"Specifications" Section). Current(mA) Conditions 110 Maximum alarm current with the buzzer sounding The large 2-line, 16-character display provides easy to read and the touchpad illuminated from a button press messages to indicate the current status of the system.The 60 Typical operation touchpad includes police,fire, and auxiliary panic buttons that can be activated anytime.A built-in speaker provides alarm, 12 Power saving mode(no panel AC power) status,and button-press sounds. A swing-down door reveals a label with basic system operating commands.The door can be Table 2.Maximumtouchpad wire lengths removed by simply opening it past its stop point.The door can Wire Gauge(Unshielded Max.Touchpad Wire Length also be reattached later if desired. or Shielded) Between Touchpad and Panel 18 750 feet Tools and equipment needed 22 300 feet • 4-conductor, 22-or 18-gauge wire Installing the Mounting Plate • Screwdriver 1. Separate the mounting plate from the touchpad by first • #6 screws and anchors (included) loosening the screw, then lift the touchpad away from the • Panhead screws for gang box installation mounting plate(see Figure 1). • Saw or utility knife for cutting wallboard Figure 1. Separating touchpad from mounting plate Installation Loosen screw, Installation guidelines Ng • Mount the touchpad in an environmentally controlled area � (32°F to 120°F/0°C to 49°C). • When mounting the touchpad,allow at least 3 inches below it for the swing-down cover. • Do not exceed the maximum available power. Seethe panel installation instructions for maximum available ^ r then lift touchpad. '- power. • Table 1 describes the power used by the touchpad. P/N 466-2100•REV I•January 2011 1 2. For wall mounting, place the mounting plate on the wall Attaching the Touchpad to the Mounting Plate and mark the mounting holes(see Figure 2). Be sure to Align the tabs at the top of the mounting plate with the slots on leave a 3-inch clearance below f or the touchpad door to the touchpad and swing the touchpad bottom toward the open. mounting plate. Gently tighten the screw into the bottom of the touchpad. Figure 2.Mounting hole locations Power up and Bus communication Mounting Holes After making all wiring connections from the touchpad to the panel,you are ready to power up the panel and verifycorrect communication between the touchpad and the panel. Upon power up,the panel scans the bus for connected devices, • . Mounting Holes assigns a unit number to each bus device, and automatically learns the device ID number of each bus device. 1. Verifythat all wiring between the panel and touchpad is 3. Insert anchors into the wall at the marked locations where correct. studs are not present. 2. Connect the panel battery and restore AC power. 4. Align the mounting plate holes with the wall or gang box Alphanumeric touchpads brief ly show SCANNING BUS screw holes and secure the back plate using the screws DEVICES, then display date and time. provided. Note: Steps 3 through 9 are optional. Note: Do not over tighten screws or the mounting plate may bind and prevent the touchpad from mounting 3. At the touchpad,enter program mode by pressing 8+ properly. installer/dealer code (def ault=4321) +0+0.The touchpad should display SYSTEM PROGRAMMING. 5. For wall-mount installations, cut a hole in the wall in the wire access area of the mounting plate to pull the wiring 4. Press E and the display shows SECURITY. cable through. 5. Press A or B until the display shows ACCESSORY MODULES,then press E.The display should read BUS Wiring the Touchpad to the Panel DEVICES. 1. Remove panel AC and backup battery power. 6. Press E.The display shows the lowest device address 2. Run a 4-conductor, 18- to 22-gauge wire from the panel to and its ID.The following example shows whata device the touchpad location(see Figure 3). address display may look like: UNIT-ID 3. Connect the touchpad+12V, BUS A, BUS B, and GND 0-02110185* terminals to the matching panel terminals(see Figure 3 for *The 8-digit SuperBus ID number is also located on a label touchpad terminal identification) on back of the touchpad. 7. Press A or B to cycle through all bus device addresses Figure 3.Touchpad wiring connections until the touchpad appears. •• • • • "•' 8. Afterverifyingthe touchpad device ID, pressc repeatedly -„ until the display shows SYSTEM PROGRAMMING. , :: 9. Press A or B until the display shows EXIT A° • *�- +++ . ; ;' PROGRAMMING READY, then press E.The touchpad BUSA +� Ynn,oimiut should show the date and time display. } - "" • Programming • ■. U,. 4: • is . , To program options for the newly installed touchpad(such as key beeps)see the specific panel insta Ila tioninstructions. 2 ATP1000 Touchpad/Display Installation Instructions Connectingthe touchpad for system 2. Connect the cable plug onto the panel Programming Touchpad Header pins(see Figure 4). programming only 3. Reconnect the AC and backup battery power.The touchpad briefly displays***********,SCANNING BUS For installations that don't include an alphanumeric touchpad DEVICES, then shows a time and date display. as a permanent part of the system,you can connect one for system programming to the Programming Touchpad Header Note: If the touchpad does not respond as described in on the panel. step 3,there may be a bus conf lict.To correct this, change the touchpad unit number as described in the section To do this you must first connect a Programming Touchpad "Changing the Touchpad Unit Number." Cable(60-791)to the touchpad wires(see Programming Touchpad CableInstaIla tion lnstructions-466-1604, included Removing the programming touchpad from Concord with the cable).Then, use the appropriate procedure for panels with software versions 1.0-1.6: connecting the touchpad. To prevent a trouble condition,you must delete the To connect a programming touchpad to a Concord programming touchpad unit number f rom Concord panel Express,Concord,or Concord Ultra panel with software memory before disconnecting it. version 2.0 or later: 1. Af ter programming is completed, return to the 1. With the panel powered up,connect the cable to the ACCESSORY MODULES menu, then press E.The Programming Touchpad Header (see Figure 4). display should read BUS DEVICES. 2. Press E.The display shows the lowest unit number and its Caution:When using the ATP1000 as a programmable device name. touchpad, be careful not to touch the circuit board exposed on the pack. 3. Press A or B until the display shows the programming touchpad unit number. Figure 4.Connectinga Programming Touchpad—Concord 4. Press D to delete the device and its unit number f rom Express Shown,ConcordSimilar panel memory.The display shows: UNIT- TYPE 14-NONE Programmi Rg Touchpad Header Pins 5. Exit program mode and disconnect the programming cable f rom the panel header. -�OEU5SMMOHNHITHHH0 Testing Note: Contact the central monitoring station before activating alarms,to avoid dispatching local police and f ire I - departments. Test the touchpad by arming/disarming the system, activating the touchpad panics,bypassing sensors,and by turning chime 2. Activate the touchpad by pressing 8+CODE+0+2. and lights on/off to verify correct operation.Ref erto the panel 3. Enter program mode by pressing 8+installer/dealer User's Manualf or complete system operating instructions. CODE+0+0 and program the panel using the panel InstallationInstructions. Adjusting display brightness and contrast 4. When programming is completed,simply disconnect the The touchpad display can be adjusted for easier viewing to programming touchpad. help compensate for lighting conditions in thetouchpad To connect a programming touchpad to a Concordpanel location. with software versions 1.0-1.6: The brightness adjustment lightens or darkens the background. 1. Disconnect AC and backup battery power. The contrast adjustment lightens or darkens the text. ATP1000 Touchpad/Display Installation Instructions 3 To adjust display brightness: Changing the touchpad unit number(Concord 1. Enter user programming mode by pressing 9+ user, partition,or system master CODE.The display shows panels with software version 1.0-1.6 only) SYSTEM MENU, then TIME AND DATE (Concord panels with sof twareversions 1.0-1.6 display Use the following guidelines when changing device unit USER CODES.) numbers to avoid communication conflicts between bus devices and the panel: 2. Press B until the display shows OPTIONS,then press E. • The display shows DOWNLOADING ON/OFF(current All bus devices with DIP switches(LED Touchpads, setting). ESMs, HIMs, etc.)must be set to the desired unit number bef ore applying power and entering program mode. 3. Press B twice and the display shows TOUCHPAD BRIGHTNESS 2(default setting). • Whenever possible,assign touchpad unit numbers bef ore all other panel programming. 4. Enter a setting from 0(darkest background)to 3 (brightest background),then press E. To change the touchpad unit number: 5. The display f lashes the entered selection,then stops of ter 1. At the touchpad, press and hold the D and 6 buttons pressing E and displays the new setting and brightness together f or at least 2 seconds. The display should show level. DA n,where n is the current touchpad unit number(000- 6. Exit user programming mode. 015). Note:At this time,the touchpad is in configuration mode To adjust display contrast: and no longer communicating to the panel.The system 1. Enter conf igaration mode by pressing the D and 6 buttons may immediately indicate a bus failure.Ignore the failure together for at least two seconds. The display showsDA and continue with the procedure.The bus f allure will clear nnn. after successf ully changing the touchpad unitnumber. 2. Press and release the 1 and 2 buttons together 2. Press E.The display shows ENTER_. repeatedly,until the desired contrast level is displayed. 3. Enter the desired three digit unit number(000-015), then 3. Press c and the display brief ly shows DONE,then shows press E.The display shows DA n,where n is the new the time and date. touchpad unit number. 4. Do not use unit number 15 in Concord RF systems. Troubleshooting 5. Press c to exit from the configuration mode. Problem Action/Solution Note: If the new touchpad unit number was previously Touchpad doesn't Check forcorrect wiring connections at learned by the panel, communication between the power up(no display touchpad and panel terminals. touchpad and the panel begins immediately. However,if and no beeps when the new touchpad unit number has never been learned by buttons are pressed). Make sure panel battery is connected correctly and that the panel transf ormeris the panel, continue with step 6. plugged in. 6. Force the panel to scan bus devices as follows: Make sure panel transformer is not plugged into an electrical outlet controlled by a switch. • For systems where this is the only installed touchpad, Relocate transf ormerto an unswitched outlet remove panel AC and battery power,then re-apply location,if necessary. power. Touchpad display Check the touchpad display contrast setting. appears blank,but It may be set to 0(no display). • For systems with more than one touchpad,go to beeps sound when another system touchpad and enter 8+ buttons are pressed. installer/dealer CODE(def ault=4321) +0+ 1. The Touchpad display Check forcorrect bus wiring connections display shows SCANNING BUS DEVICES,then a shows a f lashing*, (green and white wires)at touchpad and time and date display. indicating a trouble panel terminals. condition and system The touchpad and all other bus devices should operate doesn't respond to Make sure touchpad unit number is set to a P p commands f rom differentnumber than all other bus devices. If correctly and any bus failures should be cleared. touchpad. necessary,change the touchpad unit number (see procedure on this page).(Concord Note: If the panel still indicates a bus failure the panel may panels with software versions 1.0-1.6 only.) have previously learned a unit number that is no longer 4 ATP1000 Touchpad/Display Installation Instructions used by any bus device. See the specific panel Installation FCC compliance FCC Part 15 Information to the User Instructions for more inf ormation on deleting unused unit Changes or modifications not expressly approved numbers. by Interlogix can void the user's authority to operate the equipment. Specifications FCC Part 15 Class B This equipment has been tested and found to comply with the limits fora Class B digital device, Compatibility Concord,Concord Express,Concord Ultra pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable Power requirements 12 VDC nominal(see Figure 1 foradditional protection against interference in a residential power requirements) installation. Operating temperature 32°to 120°F (0°to 49°C) This equipment generates,uses, and can radiate Humidity 95%relative,non-condensing radio frequency energy and,if not installed and used in accordance with the instructions,may Dimensions 5.0"x 4.5 x.75"(L x W x D) cause harmfulinterferenceto radio communications.However,there is no guarantee that interference will not occur in a particular installation. Regulatory information If this equipment does cause harmf ulinterf erence to radio or television reception,which can be Manufacturer UTC Fire&Security Americas Corporation, Inc. determined by turning the equipment offand on, 1275 Red Fox Rd.,Arden Hills, MN 55112-6943, the user is encouraged to try to correct the USA interference by one or more of the following UL listings UL 985 Household Fire Warning System Units measures: UL 1023 Household Burglar-Alarm System Units • Reorient or relocate the receiving UL1610 Central Station Burglar-Alarm Units antenna. (Commercial Burglary) • Increase the separation between the Note:See specif icpanel Insta Ila tionlnstructions forcomplete UL installation requirements f orthe equipment and receiver. system you are installing • Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. Contact information For contact inf ormation,see www.utcfireandsecurity.com or www.interlogix.com. For technical support,Toll-free:888.437.3287 in the US including Alaska,Hawaii, Puerto Rico,and Canada. Outside the tool-f ree area:Contact your dealer. Copyright©2011 Interlogix,a UTC Fire&Security Company. All rights reserved. ATP1000 Touchpad/Display Installation Instructions 5 interlogix A UTC Fire&Security Company 4-Output Expansion SnapCardTM Installation Instructions Product summary Installation The 4-Output Expansion SnapCard' allows you to control Installation requires you to install the SnapCard,wire all output devices by adding hardwire outputs to Concord,Concord 4, devices, and program the panel. Concord Express(v4),and Advent panel. For all Concord panels,the expansion SnapCard can be Figure 1.4-Output expansion SnapCardcomponents installed on to the expansion connector.For Advent panels, the 4 RELAY OUTPUT expansion SnapCard can be installed in combination with other EXPANS ION SNAPCARD MOUNTING PANEL SCREW cards on either the primary or secondary expansion slot. RELAYS(4) CONNECTOR HOLES(2) The SnapCard uses f our,"Form C"dry contact relays.The relays are controlled by a touchpad or by a combination of states and events within the security system. 0 0 Examples of programmed outputs include turning on a CCTV or camera during a burglary alarm;turning on exit lights during f ire alarms;and activating backup cellular phones or long- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 range radios when primary communications are inoperable. Installation guidelines WIRING TERMINALS • Refer to specific panel/nsta lla tionlnstructions for maximum wire length limits. Caution:You must be f ree of static electricity when handling • Use four-conductor,22-gauge or larger diameter stranded electronic components.Touch a grounded, bare metal surf ace wire f rom terminals to devices. bef oretouching the circuit board. • All Advent f ire panel wiring must be in accordance with 1. Disconnect panel AC power and any backup battery. NFPA codes and standards. 2. Align the SnapCard's mounting holes with the panel's Note: For Advent panels, SnapCard expansion standoffsand connector pins. Ref er toFigure 2 for connectors must be used for either f ire or burglary Concord,Concord Express V4, and Concord 4 panels; applications.Do not combine f ire and burglary applications Figure 3 for Concord Express panels; and Figure 4 for on SnapCard inputs and outputs. Advent panels. Tools needed • Slotted and Phillips screwdrivers • 22-gauge or larger diameter stranded wire • Mounting screws(included) P/N 466-1366 • REV E • January 2011 1 Figure2.Concord,Concord4,orConcordExpressV4 SnapCard Figure4.Advent SnapCardinstallation installation CONTROL PANEL SECONDARY EXPANSION ® R:: 10 CIRCUI T BOARD CARD CONNECTO PRIMARY EXPANSION CARD CONNECTOR 31 OPTIONAL - EXPANSION CARD CONTROL PANEL • CONNECTOR CIRCUIT BOARD ��n B = Hill I \ 0 O O 0 ALIGN BOARD mil HOLES WITH ®®®®®®®®®®®®®®® II -- STANDOFFS O ALIGN BOARD 0 EXPANSION CARD 0 i(2) O III O HOLES WITH DOUnddffidHHOM STANDOFFS I (2) I ' 1 O OPTIONALO ' 1 EXPANSION CARD i n0000100000000 3. To seat the card,firmly press it on to the connector. 4. Secure the card to the panel with the mounting screws. Wiring Note: Class 2, Class 3, and power-limited f ire alarm circuits must be installed using FPL,FPLR,FPLP,or substitute cable Figure 3.ConcordExpress SnapCardinstallation as permitted by the National Electrical Code ANSI/NFPA 70. Wires that extend beyond the cable jacket must be separated from all other conductors by a minimum 1/4" or by a non- conductive barrier. Class 2, Class 3, and power-limited f ire ® ° ® I alarm circuit conductors must be installed as Class 1 or higher _ rated circuits. iil ® a ��0 mss, Ref erto Table 1 f or a description of each SnapCard terminal. ® o ® Terminals are numbered f romlef t to right. Figure 5 (pg. 3) Eil �` ���� illustrates how to wire the expansion SnapCard. go go ® ° - Ism II ® Note: Each terminal listed in Table 1 is a Class 2 power-limited i ®OAC terminal PUSH SNAPCARD CONNECTOR 0 s I ONTO PANEL HEADER —6 Table 1.SnapC ardwiring terminal descriptions SECURE SNAPCARD WITH Terminal Description Use TWO SCREWS number 8642G31A.DSF 1 Relay 1 NC Normally closed(N/C) Output 1 dry relay contact connection. 2 Relay 1 COM Common(C)side of Output 1 dry relay N/C and N/O contacts(terminals 1 and 3).Contacts rated 4A @ 24V DC;4A @ 24V AC; 1A @ 70V AC maximum. 3 Relay 1 NO Normally open(N/O)Output 1 dry relay contact connection. 4 Relay 2 NC Normally closed(N/C)Output 2 dry relay contact connection. 2 4-Output Expansion SnapCard Installation Instructions 5 Relay 2 COM Common(C)side of Output2 dry relay Troubleshooting N/C and N/O contacts(terminals 4 and 6).Contacts rated 4A @ 24V DC;4A @ 24V AC; 1A @ 70V AC maximum. 6 Relay 2 NO Normally open(N/O)Output 2 dry Table 2.Troubleshooting hardwire outputs relay contact connection. Problem Action/Solution 7 Relay 3 NC Normally closed(N/C)Output 3 dry Outputs do not activate • Check panel/card programming. relay contact connection. • Check output wiring connections. 8 Relay 3 COM Common(C)side of Output 3 dry relay N/C and N/O contacts(terminals 7 and • Check panel/card power supplies. 9).Contacts rated 4A @ 24V DC;4A • Check optional external power @ 24V AC; 1A @ 70V AC maximum. supply to output devices. 9 Relay 3 NO Normally open(N/O)Output 3 dry One output fails to • Check specific panel/card relay contact connection. activate. programming outputs. 10 Relay 4 NC Normally closed(N/C) Output 4 dry • Check output wiring connections. relay contact connection. • Check f orprogrammed trigger 11 Relay 4 COM Common(C)side of Output 4 dry relay events. N/C and N/O contacts(terminals 10 The wrong output • Check panel output programming. and 12). Contacts rated 4A @ 24V activates. DC;4A @ 24V AC;1A @ 70V AC • Check output device wiring maximum. connections. 12 Relay 4 NO Normally open(N/O)Output 4 dry relay contact connection. Specifications 13 GND Common ground return connection f or Compatibility Interlogix/GE Concord,Concord 4,Concord 12V DC supply output. Express(v4),and Advent panels. 14 +12VDC Auxiliary output regulated DC power Power requirements 12V DC @ 142 mA typical with each 34 mA supply.12 VDC @ 0.5A maximum. This output draws 500 mA from the relay energized. panel.Remember to include this Outputs Four panel-programmable outputs with current draw when calculating total Form-C relay contacts(Common,N/C,N/O). panel power. Relay contacts rated 4A @ 24V DC;4A @24V AC; 1A @70V AC maximum. One 12V DC,500 mA regulated power Wiringthe SnapCard to a Panel output from panel.6 W maximum. 1. Disconnect panel AC power and any backup battery. Storage temperature 40°to 140°F (-40°to 60°C) Operating temperature 32°to 140°F (0°to 60°C) 2. Wire each output device as shown in Figure 5. Maximum humidity 90%relative humidity, non-condensing 3. Reconnect the backup battery and restore panel AC Dimensions 2.0"x 5.25"x 0.75"(H x W x D) power. Installation In-panel cabinet mounting. Programming In order for outputs to properly f unction,each output must be programmed into panel memory.Ref erto specific panel Insta Ila tionlnstructions for programming inf ormation. Testing Once installed, the card becomes an integral operating component for the panel. It is recommended that you test each output device af ter programming is completed. Ref erto specific panel Insta lla tionlnstructions or User's Manualf or output testing inf ormation. 4-Output Expansion SnapCard Installation Instructions 3 Figure 5.4-Output expansion SnapC ardwiring diagram 4 OUTPUT EXPANSION SNAPCARD TERM INALS RELAY 1 RELAY 2 RELAY 3 RELAY 4 0.5A MAX NC CO M NO I NC CO M NO I I NC CO M NO I NC CO M NO I GND +12V 0 011 011 0/ 0,1 0,1 011 011 011 011 011 011 011 011 NOTE:DO NOT EXCEED OUTPUT RELAY CONTACT RATI NGS 2.0k Ohm 1/2 W Ic urrent % : 11101/19 resi story OUTPUT DEVICE CONTRO L 4)LE D (NO) TYPICAL OUTPUT DEVICE APPLICATION TYPICAL LED INDICATOR APPLICATION *0.5 AMP MAX.DO NOT EXCEED POWER SUPPLY CAPACITY. Regulatory information Manufacturer UTC Fire&Security Americas Corporation, Inc. 1275 Red Fox Rd.,Arden Hills, MN 55112-6943, USA FCC compliance: FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix can void the user's authority to operate the equipment. FCC Part 15 C lass A This equipment has been tested and found to comply with the limits f ora Class A digital device,pursuant to Part 15 of the FCC rules.These limits are designed to provide reasonable protection against harmf ulinterferencewhen the equipment is operated in a commercial environment. This equipment generates,uses, and can radiate radio f requencyenergy and, if not installed and used in accordance with the instruction manual, may cause harmf ulinterferenceto radio communications.Operation of this equipment in a residential area is likely to cause harmf ulinterf erence in which case users will be required to correct the interference at their own expense. FCC Part 15 C lass B This equipment has been tested and f oundto comply with the limits f ora Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates,uses, and can radiate radio f requencyenergy and, if not installed and used in accordance with the instructions,may cause harmf ulinterferenceto radio communications.However,there is no guarantee that interf erence will not occur in a particular installation. If this equipment does cause harmf ulinterferenceto radio or television reception,which can be determined by turning the equipment offand on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. Connect the affectedequipment and the panel receiver to separate outlets,on differentbranch circuits. Consult the dealer or an experienced radio/TV technician forhelp Contact information For contact information,see www.utcfireandsecurity.com or www.interlogix.com. For technical support,toll-f ree:888.437.3287 in the US including Alaska, Hawaii, Puerto Rico,and Canada. Outside the tool-free area,contact your dealer. GE is a trademark of the General Electric Company and is under license to UTC Fire&Security, 9 Farm Springs Road, Farmington,CT 06034-4065 Copyright©2011 Interlogix,a UTC Fire&Security Company.All rights reserved. 4 4-Output Expansion SnapCard Installation Instructions INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEMco i4 SENSOR® Series Interface Module 3825 Ohio Avenue,St.Charles,Illinois 60174 COSMOD2W and COSMOD4W 1-800-SENSOR2,FAX:630-377-6583 *For use with COSMO-2W and COSMO-4W detectors www.systemsensor.com SPECIFICATIONS Electrical Specifications Power Supply Voltage: Resettable power;2-Wire:Min.8.5 Volts DC(Power limited);Max.35 Volts DC(Power limited); 4-Wire:Min. 10 Volts DC(Power limited);Max.35Volts DC(Power limited) Device Power-up Time: 200 milliseconds Standby Current: 2-Wire: 61mA (max.), 45mA (12V In), 26mA (24V In); 4-Wire: 52mA (max.), 37mA (12V In), 22mA (24V In) (Does not include current draw from attached detectors or EOL relay) Alarm Current: 2-Wire: 181mA(max.), 121mA(12V In), 64mA(24V In); 4-Wire: 78mA(max.), 57mA (12V In), 34mA (24V In) (Does not include reverse polarity current draw from attached detectors) Alarm Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Maintenance Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Max.IDC Loop Wiring Resistance: 2-Wire:50 Ohms;4-Wire:300 Ohms Trigger Inputs: Min.On Voltage: 1.5V;Max.On Voltage=Vin Aux Power Out: Same Voltage as Input Power(Unregulated,limited to 250mA) Min.Reset Time: 300 milliseconds Initial Communication Cycle: 6 minutes EZ Walk Test Availability: 6 minutes after power up or panel reset Physical Specifications Operating Temperature Range: 0-50°C(32-122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20-70°C(-4-158°F) Height: 6.04 inches Width: 6.04 inches Depth: 1.16 inches Shipping Weight: 0.6lbs Wire Gauge Acceptance: Min:22 AWG;Max: 14 AWG 2-wire Compatibility Requirements Min.Loop Voltage: 12.9 Volts DC Max.Loop Voltage: 14.5 Volts DC Max.Loop Resistance: 50 Ohms Max.Loop Ripple: 240 mVpp Max.Loading Capacitance: 0.01 mF Max.Alarm Current: 46 mA Max.Reset Voltage: 0.30 Volts DC Alarm Delay: n/a Min.Alarm Reset Time: 0.3 seconds Max.Normal Load Current: 2.4 mA Zone Type: Standard EOL Device: 3.9k Ohms(+-5%) Loop Style: B and D Compatibility Zone Identifier: A Detector Zone Identifier: A Max.Detectors Per Zone: (12)2-wire i4 series model#COSMO-2W and/or i3 series model#2WTA B detectors BEFORE INSTALLATION MOD is not required) Local status indication is provided by 4 LED's and a 3 This information is included as a quick reference installation guide. Refer to position DIP switch enables user configuration. the control panel installation manual for detailed system information. If the The i4 COSMOD2W, 2-wire interface module, offers additional functionality module will be installed in an existing operational system,inform the operator including: and local authority that the system will be temporarily out of service.Discon- nect power to the control panel before installing the module. • Ability to query for a "need for maintenance" condition from 2-wire i4 series model COSMO-2W and i3 series model 2WTA B smoke detectors Notice: This manual should be left with the owner/user of this equipment. This product is intended for use in ordinary indoor locations. • One relay is available to indicate a multitude of maintenance conditions GENERAL DESCRIPTION at the control panel The i4 series module is designed to interface between compatible i4 series • All conditions are displayed at the module and at the detector combination CO/smoke detectors (Model COSMO-2W and COSMO-4W) and • EZ Walk test mode allows the installer to easily verify that al ldetectors compatible security/fire panels. It can also be used to retrofit compatible i4 on a l oopare operational series detectors into an existing 1 oopof i3 smoke detector models 2WTA B or • Allows 2-wire smoke detectors to be used on any compatible 4-wire 4WTA-B,without adding wires.The module interprets signals and translates control panel and provides Style D/Class A wiring on the detector 1 oop them into a separate smoke zone and a separate CO zone, each with alarm and trouble signals.The module will interconnect the detectors connected to FEATURES it and alarm them in either Temporal 3 or Temporal 4 pattern. Optional trig- • Compatible with System Sensor i4 series combination CO/smoke detectors gers are provided to initiate multiple modules to sound. (an additional RSS- and System Sensor i3 Series smoke detectors models 2WTA B or 4W/TA-B. 1 I56-3871-004 06-10 • Allowsup to 12 compatibledevices including the i4 series combination A CO alarm is self-clearing.Once a CO alarm has been signaled,the blueLED CO/smoke detector to be integrated with a panel will illuminate. Once the initiating device ceases to signal the CO event,the • Activates sounders of all detectors on 1 oop in either Temporal 3 or blue LED will turn off.If a CO al arm is signal ed,and not cl eared,prior to a Temporal 4 pattern smoke al arm condition,the module will keep both the blue and red LED's illuminated.If a smoke al armis signaled first,the modul ewil l not be abl e to VISIBLE ANNUNCIATON receive notification of a CO alarm condition and will not be able to report it The i4 series interface modul ehas four visible LED's:The green LED is a su- to the panel. pervisory LED;it blinks during power on,reset,and during normal operation. MAINTENANCE The yellow LED is used to indicate a 1 oop wiring fault and will bl inkwhen it is in EZ Walk test mode.The red LED signal s smoke events;it blinks during This condition means one or more detectors on the loop have a smoke main- smoke maintenance events and 1 ightsconstantly during smoke al armevents. tenance issue.See"Smoke Maintenance Inquiry"section for further details. The blue LED signals CO events;it blinks during CO trouble or CO end-of-life, FREEZE TROUBLE and lights constantly during CO al arm. This condition means one or more detectors on the 1 oop are measuring the FIGURE 1MODULE FRONT VIEW ambient temperature is near the freezing point.See"Freeze Trouble Inquiry" /T ` section for further details. / s CO TROUBLE The modulecan be notified of a detector with a CO trouble condition.A11CO trouble conditions will be reported on the CO zone and displayed with a bl ink- Green LED ►© a w o°NwNCAna ing blue LED.The module is not able to determine the number of detectors Yellow LED / m n't:QUMW" that have a CO trouble condition or which trouble condition exists. Red LED ►©°1"-a nnnr °"-"1p° irwirr INSTALLATION Blue LED 0 ©1 8SY MOUNTING EZ Walk Test Switch Pr®1a1RwANcli� 2-wire only ► numnmNn.wcwNor RMISI L19100111LE The modul ecan be mounted to a 4"/6 inch back box or inside a l isted,dedi- NJRINAINlMIiN• O CAUTION cated enclosure.When mounting inside an enclosure with pre-stamped holes, Po VNNrr it may be easier to align the bottom screw hole first.It is not necessary to use 50331-00 the modul ecover when mounting inside an enclosure. TABLE 1:OP ERATION MODES FIGURE 2:MOUNTING OPERATION GREEN YELLOW HOLE FOR MOUNTING TO VISTA ENCLOSURE RED LED BLUE LED (No.6x3/4 Type AB) MODE LED LED e Normal(standby) Blink 1 Sec. OFF OFF OFF Oil © No power/ OFF OFF OFF OFF r Non-operational I.M1 i 1 © IST Loop wiring fault Bl ink 1 Sec. ON OFF OFF (I,I M1 M EZ Walk Test Mode II iM B1ink 1 Sec. Blink5 Sec. I OFF OFF IMI 0 1i (2-wire only) INI WI l Alarm Smoke Bl ink 1 Sec. OFF ON OFF (I t 1 © I I!., d '[ 1 0 � Alarm CO Bl ink 1 Sec. OFF OFF ON 'I1 lL Alarm Smoke&CO Bl ink 1 Sec. OFF ON ON I= S1 Q o 8 Maintenance Blink 1 Sec. OFF Bl ink 5 Sec. OFF 1 _/ (2-wire only) Freeze Trouble SLOT FOR MOUNTING SLOTS FOR MOUNTING Blink 1Sec. OFF B1 ink 10 Sec. OFF TO VISTA ENCLOSURE T04-11/1fiJUNCTION80X (2-wire only) (No.6x5/16Type AB or Type F) CO Trouble Bl ink 1 Sec. OFF i OFF Blink 5 Sec. S0332-00 WIRING GUIDELINES NORMAL(STANDBY) All wiring must be installed in compliance with the NFPA 70 standards,Na- The modul eis powered and detectors on the loop are operating normally. tional Electrical Code,appl icabl estate and local codes,and any special re- NO P OWER/NON-OPERATIONAL quirements at the 1 ocalAuthority Having Jurisdiction(AHJ). Power is not applied to the module or communication between the module The screw terminals in the mounting base will accept 14-22 gauge wire.Wire and the detectors on the loop is unsuccessful. connections are made by stripping approximately 1/4" of insulation from the LOOP WIRING FAULT end of the feed wire,inserting it into the proper base terminal,and tightening If an open circuit occurs on the 1 oop,the module will indicate the condition by the screw to secure the wire in pl ace.Do not put wires more than 2 gauge illuminating the yellow LED.2-wire units wil lthen power the Style-D/Class A apart under the same clamping pl ate. terminals. When the wiring issue on the loop has been resolved,the module Note:The module must be installed in the same room and within 20 feet of wil lturn the yellow LED off. the panel and enclosed within conduit or equivalently protected against me- EZ WALK TEST MODE chanical injury. This indicates the module and detectors are in EZ Walk Test Mode.See"EZ Walk QWARNING Test"section for instructions on how to initiate and perform the EZ Walk test. Remove power from al armcontrol unit or initiating device circuits before in- ALARM SMOKE/ALARM CO/ALARM SMOKE&CO stalling detectors. A smoke alarm wil lbe indicated by the red LED.A CO alarm wil lbe indicated by the blue LED. WIRING DIAGRAMS A smoke al arm is not self-restoring. Once a smoke al arm has been signaled, Install module wiring in accordance with appropriate wiring diagrams. the red LED wil lilluminate until the modul eis reset by removal of power. (Figure 3 and Figure 4) Note:On some panels,resetting a smoke al arm may require additional steps The module relays have a maximum ON resistance of 25 ohms. This resis- at the keypad to cl earthe trouble conditions on CO and smoke mainte- tance plus the wiring resistance to the panel must be less than the maximum nance zones due to power loss to the module. zone wiring resistance stated in the panel manual. 2 156-3871-004 06-10 FIGURE 3:COSMOD2W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED Note:See Table 2 for dip (EXCEPT TRIGGERS)AND MUS SWttCh configurations SMOKE 0 BE POWER LIMITED AUXPOWER 0 r ''yy (resettable) — e Com= ©° ® 05 ■ ' \tig _, „_, "40,,,V4:,--2:: 0 r E - , j Panel SMOKE 0 EOL 1. ZONE . ' Resistors gT,o±'• �O o � V ® o ,II 3.9k - e ® ®ld RESISTOR ORO K", I r a (supplied CO 0 - - O - - I �/® with module)) ZONEO I I I I I � ,,, —/-0\--'— ,-, _ _ _ I I \ MAINT. O COSMOD2W LOOPSTYLED/CLASS A WIRING ZONE O- -Panel I COSMO-2W BELL n, Resistor I , I I I OR 1 F —I SMOKE I TRIGGER OUTi L J I JJJJ 50329-00 CO TRIGGER i OUT i- FIGURE 4:COSMOD4W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED SMOKE 0 (EXCEPT TRIGGERS)AND MUST BE POWER LIMITED POWER 0 e �_ (resettable) e 0 ©- 13 e Op Panel C�� SMOKE 0 . Yl EOL �: �I E41 os 11 ZONE O I. :,1 �l j Resistors / ,,/ �) � Ill © I- fII ,` ® I II 6l J 1' + 1 3.9k 0O �' RESISTOR CO 0' �- —— .'i 4 — , _. 0 '% (supplied ZONE OI �� with module) 8 o c, B I COSMOD4W COSMO-4W I I BELL n, I OR F —I SMOKEL , J 50330-00 TRIGGER OUT I CO TRIGGER OUT L ' FIGURE 5:MODULE TERMINALS 00 go % POWER IN + *0I 1. ` I Ie SMOKE ZONE EOL RESISTOR POWER IN— al O le (VALUE DEFINED BY PANEL) SMOKE ALARM CONTACT ( I I O I ,CO ZONE EOL RESISTOR .all (tt (VALUE DEFINED BY PANEL) MAINTENANCE TROUBLE RELAY CONTACT all O (' IDC+ (COSMOD2W ONLY) I I l t IDC— CO ALARM CONTACT O (`: r STYLE D/CLASS A+(4-WIRE DETECTOR POWER+) el O I Ig STYLE D/CLASS A—(4-WIRE DETECTOR POWER—) CO TRIGGER Ie SMOKE TRIGGER/BELL IN ci9 El(1Z5\--7-C-3\ 1,Q S0334-02 3 I56-3871-004 06-10 INP UTTRIGGERS/SOUNDER ACTIVATION FREEZE TROUBLE INQUIRY Many panels can be programmed with triggers which are auxiliary relays that The module sends a freeze trouble inquiry to the detectors every four hours. activate upon an alarm condition. Two inputs are used to signal the module (Compatible i3 Series 2-wire smoke detectors only)If a response indicating a to activate device sounders.The first is configurable by DIP switch to one of freeze problem is received,the red LED on the module will blink once every two modes;bell in or smoke trigger.When in the bell mode,the module will 10 seconds and a smoke maintenance condition will be indicated to the panel. follow a valid coded signal from a Bell Out/NAC circuit consisting of high to TESTING low,then 1 owto high for 1 essthan 1.9 seconds each.In smoke trigger mode, Modules must be tested after installation and following periodic maintenance. while the input is held high,the module wil lsynchronize the detectors in a Testing should be performed at least once per year. Temporal 3 pattern. NOTE:Before testing,notifythe proper authorities that the systemwill be tempo- The second input is for a CO trigger;the CO trigger input allows a single mod- raril Wut of service.Disable the zone or system to prevent anyunwanted alarms. ul e to have CO silence/hush capability and allows multiple module installa- tions to have all sounders activated in Temporal 4 in the event of a CO alarm. EZ WALK TEST While the CO trigger is held high,with a positive voltage input,the module The communication loop between the 2-wire modules and detectors can be will synchronize the detectors in a Temporal 4 pattern. After 30 minutes in manually tested by putting the module and detectors into EZ Walk test mode. Temporal 4 alarm,the time period between the Temporal 4 pulse will change This feature is for use with SystemSensor detectors(i4 series model COSMO-2W from 5 seconds to 60 seconds. and i3 series model 2WTA B)installed with the model COSMOD2W module. Note: CO trigger may only be used with UL 864 panels that have been evalu- The EZ Walk loop test verifies the initiating 1 oop wiring and provides visual ated to confirm CO services:A)The control unit shall be capable of distinctively status indication at each detector: indicating the activation of a CO detector as a carbon monoxide alarm signal B) 1. Ensure proper wiring and power is applied. Wait approximately 6 min- The visible annunciation of an activated carbon monoxide detector at the control utes from power-up before performing the EZ Walk test.The green LED unit shall not be canceled when the carbon monoxide audible alarm signal is de- on the module must be blinking indicating the module is in ready/ activated,For installations other than residential applications,the interconnected standby mode to start the EZ Walk mode. control unit must produce the T4 alarm pattern via separate NAC(s). 2. Locate the EZ Walk recessed test switch located behind the module cover TABLE 2:DIP SWITCH CONFIGURATIONS (See Figure 1).Depress the test switch with a small screwdriver. The yel- DIP SWITCH#1 DIP SWITCH#2 DIP SWITCH#3 low LED will blink showing that the module and detectors are in EZ Walk Smoke Maint on mode for 5 minutes. ON Bell i„ Smoke Trouble and Unused 3. Observe the LEDs at each detector to make sure the green LED is double (DEFAULT) Form-B Maint Relay blinking every 5 seconds as listed in Table 3. (COSMOD2W only) 4. At the end of the five minute period,the module will terminate EZ Walk Smoke Maint on and the yellow LED wil lstop blinking. The EZ Walk test period can be OFF Smoke Trigger Form-B Smoke main- Unused extended by pressing the test switch multiple times.Each press will add tenance Relay only 5 minutes of additional time. (COSMOD2W only) If a module or detector fail sthe test,its wiring should be checked. If the POWER UP AND COMMUNICATIONS module still fails,it should be replaced.Notify the proper authorities when all COMMUNICATIONS CHECK(2-WIRE ONLY) testing has been completed. Upon power up,the module will send a request for communication check.All NOTE:The EZ Walk 1 ooptest should not be used in lieu of functional testing compatible detectors on the loop that understand the communication protocol (alarm,trouble and other functional tests)of the system. will respond.If al ldetectors respond correctly,the green LED will blink once every 1 second.If the module does not get a response,it will turn off the green TABLE 3:EZ WALK TEST DETECTOR MODES LED and continue to try every 2 minutes until a response is received. DETECTOR DETECTOR SMOKE MAINTENANCE INQUIRY GREEN LED RED LED The module sends a smoke maintenance inquiry to the detectors every 24 PROPER OPERATION Double Blink 5 Seconds OFF hours. (Compatible 2-wire detectors onl y)If a response indicating a mainte- nance problem is received,the red LED on the module will blink once every 5 OUT OF SENSITIVIY OFF Double Blink 5 Seconds seconds and a smoke maintenance condition will be indicated to the panel.It FREEZE CONDITION OFF Double Blink 10 Seconds is likely that the detector needs to be cleaned or replaced,refer to the detector instruction manual for maintenance instructions. FCC STATEMENT This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and(2)this device must accept any interference received,including interference that may cause undesired operation. NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installa- tion.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed product to be free from defects in materials and TX 79936,USA.Please include a note describing the malfunction and suspected cause workmanship under normal use and service for a period of three years from date of of failure.The Company shall not be obligated to replace units which are found to be manufacture.System Sensor makes no other express warranty for the enclosed product. defective because of damage,unreasonable use,modifications,or alterations occurring No agent,representative,dealer,or employee of the Company has the authority to in- after the date of manufacture.In no case shall the Company be liable for any consequen- crease or alter the obligations or limitations of this Warranty.The Company's obligation hal or incidental damages for breach of this or any other Warranty,expressed or implied of this Warranty shall be limited to the replacement of any part of the product which is whatsoever,even if the l oss or damage is caused by the Company's negligence or fault. found to be defective in materials or workmanship under normal use and service during Some states do not allow the exclusion or limitation of incidental or consequential dam- the three year period commencing with the date of manufacture.After phoning System ages,so the above limitation or exclusion may not apply to you.This Warranty gives you Sensor's tol lfree number 800-SENSOR2(736-7672)for a Return Authorization number, specific legal rights,and you may al sohave other rights which vary from state to state. send defective units postage prepaid to:Honeywell,12220 Rojas Drive,Suite 700,El Paso 4 I56-3871-004 ©2016 System Sensor.06-10 INSTALLATION AND MAINTENANCE INSTRUCTIONS *:-Th_ SYSTEMi4 Series Combination Carbon ) SENSOR® o Monoxide(C0)/Photoelectric Smoke Detector 3825 Ohio Avenue,St.Charles,Illinois 60174 COSMO-2W (2-w ire)and COSMO-4W (4-wire) 1-800-SE NSOR2,FAX:630-377-6583 www.systemsensor.com SPECIFICATIONS COSMO-2W COSMO-4W Electrical Specifications Physical Spcecificaitons System Voltage: 12/24 volts DC 12/24 volts DC Operating Temperature Range: 0-50°C(32-122°F) Min: 8.5 volts 8.5 volts Operating Humidity Range: 20-95%RI-1 Max: 35 volts 35 volts Storage Temperature Range: -10-70°C(14-158°F) Max Startup Current: 200uA 200uA Diameter: 5.5 inches Max Standby Current: 50uA 50uA Height: 2.5 inches Max Alarm Current: 50mA 40mA Weight: 9.2 oz;261 g Max Reverse Polarity Current: 20mA 20mA Wire Gauge Acceptance: Min:22 AWG Max:14 AWG Audible Signal(Supplemental*): 85dBA 85dBA 2-Wire Compatibility Zone Identifier: A Max Start-up Capacitance: .10uF .10uF *NFPA requires a UL listed sounder on the NAC circuit Notice:This manual shall be left with the owner/user of this equipment. alarm and CO alarm events.The red LED signals smoke events;it blinks dur- BEFORE INSTALLATION ing smoke maintenance events and lights constantly during smoke alarm Please read this manual thoroughly along with manual I56-3871 for the i4 events.The blue LED signals CO events; it blinks blue during CO trouble or series interface module and the Application Guides for System Sensor Smoke CO end-of-life; it blinks rapidly during RealTest®; and lights constant during (SPAG91) and CO Detectors (COAG103), which provide detailed information CO alarm. on detector spacing, placement, zoning, wiring, and special applications. TABLE 1:OPERATION MODES These manuals are available online at www.systemsensor.com. OPERATION GREEN IMPORTANT:This detector must be tested and maintained regularly following MODE LED RED LED BLUE LED SOUNDER NFPA 72/NFPA 720 requirements.At a minimum,cleaning and Normal(standby) Blink 5 Sec. OFF OFF OFF testing should be performed annually. GENERAL DESCRIPTION Alarm Smoke OFF ON OFF Temp 3 The i4 series is a plug-in, system-connected, combination carbon monoxide/ Alarm CO OFF OFF ON Temp 4 smoke detector.It is available in either a 2-wire or 4-wire configuration.The i4 Alarm Smoke&CO OFF ON ON Temp 3 series detectors must be used with the corresponding i4 series Interface Mod- RealTest®to connect to the panel.The i4 interface module is also compatible with i3 RealTest®Mode OFF OFF Blink 1 Sec. OFF series smoke detector model 2WTA B or 4WTA B. (After Coissprayed) OFF OFF ON Temp 4 FEATURES Trouble feature: When the sensor (supervision) is in a trouble condition Smoke Features (such as a detector that is dirty),the detector will send a trouble signal to the • Photoelectric smoke sensor module then to the FACP.Depending on the issue,the detector must then be • Drift compensation and noise rejection algorithms serviced or replaced. • Red smoke LE Dindicator CO sensor end-of-life timer feature:When the CO sensor has passed end-of- • Smoke test switch life,a trouble signal will be sent to the module then to the FACP.This indicates that the CO sensor inside the detector must be replaced.If unresolved for 30 CO Features days,the detector will chirp intermittently.The typical life of the CO sensor • Field replaceable,electrochemical CO sensor is six years from the date of manufacture;it is recommended to periodically • RealTest®functional test capable check the"Replace by"sticker located on the replaceable CO cell. • Blue CO LE Dindicator INSTALLATION GUIDELINES • Sensor end-of-life notification Ceiling:Detector should be at least 12 inches from any wall. Audible Annunciation Wall:Detector should be no closer than 6 inches from ceiling. • Local integral sounder • Do not install outdoors or in any environment that does not complywith • Polarity reversal the detector's environmental specifications Installation and Maintenance • Install in accordance with NFPA 72 and 720 standards.NFPA 72 and • Stop-Drop-N-Lock plug-in base 720 define standards for both commercial and residential installation of • SEMS wiring terminals smoke and CO detectors. State and local laws involving CO detection • COSMO-2W designed for 2-wire i4 Zone type should also be considered. • COSMO 4W designed for 4-wire i4 Zone type • If the installation can be interpreted as residential, consult the section of NFPA 720 that outlines residential applications.Chapter 9.4.1.1,for • SENS-RDR sensitivity reader compatible with extended range example, states that carbon monoxide alarms or detectors shall be in- • Removable cover for cleaning stalled as follows: • Replaceable screen • Outside each separate dwelling unit sleeping area in the immediate Other Features vicinity of the bedroom • Green supervisory LED • On every level of a dwelling unit,including basements • Listed to UL standards 268 and 2075 • Consult NFPA 72,the local Authority Having Jurisdiction(AHJ),and/ VISIBLE ANNUNCIATON or applicable codes for specific information regarding the spacing and The i4 series detector has three visible LED's;Green,Red and Blue.The green placement of smoke detectors. LED is a supervisory LED;it blinks during power on,reset,and during normal • Do not install detectors in the following areas: operation.It is extinguished during smoke maintenance, CO trouble, smoke • Inornearareas whereparticles of combustion arenormally present suchas 1 I56-3747-003R 06-10 kitchens,in garages,near furnaces,hot water heaters,or gas space heaters. the end of the feed wire,inserting it into the proper base terminal,and tight- • In very cold or very hot areas. ening the screw to secure the wire in place.Do not put wires more than 2 • In wet or excessively humid areas,or next to bathrooms with showers. gauge apart under the same clamping plate. • In dusty,dirty,or insect-infested areas. AWARNING • Near fresh air inlets or returns or excessively drafty areas.Air con- ditioners, heaters,fans, and fresh air intakes and returns can drive Remove power from alarm control unit or initiating device circuits before installing detectors. smoke away from the detector. Note:This unit is UL listed as containing a supplemental sounder and should 1. Removedetector frompackaging and separate thebasefromthedetector head. not be used as a primary sounder for evacuation. 2. Wire the detector base screw terminals. FIGURE 1:ALARM LOCATION DIAGRAM FOR RESIDENTIALAPPLICATION 3. Screw the base of the detector onto an electrical box,or to the surface of the wall or ceiling using the hardware included in the packaging. 4. Attach the detector head to the base by applying light pressure and rotat- T • ing clockwise.The detector will lock in place when properly aligned. BEDROOM 5. After all detectors have been installed,apply power to the alarm control unit.Refer to Table 3 for time to LED stabilization. Once stabilized,the • 11 green LEDwill blink once every 5 seconds. TO BEDROOM BR BEDROOM 6. Test each detector as described in the Testing section. • 7. Notify the proper authority that the system is in operation. KITCHEN— GARAGE LIVING • CLOSED ROOM DOOR ACAUTION S0295-01 NFPA 72 recommends the installation of detectors only after completing construction or BASEMENT any other dust producing activity U-CARBON MONOXIDE/SMOKE ALARM LOCATION FOR MULTI-LEVEL RESIDENCE TABLE 2:LED INDICATION DURING POWER UP SEQUENCE MOUNTING Green LED Red LED Blue LED The i4 detector can be ceiling mounted or wall mounted: No Power OFF OFF OFF 1. To a single gang box,2 in.by 4 in.box,31 in.or 4 in.octagonal or 31/ in.or 4 in.round ceiling Power on Reset Blink 5 Sec. Blink 5 Sec. Blink 5 Sec. 2. Direct mount to ceiling or to wall using drywall fasteners TABLE 3:POWER UP TIME TO FIRST ALARM/LED STABILIZATION FIGURE 2:MOUNTING OF DETECTOR Power Up Time 45 Seconds I 0 ■ 0 I Power up time after 15 Seconds 10 second reset LED Indication time Typical:45 seconds _ irf — Maximum:55 seconds \\ /�—, Status LE D indication Typical:55 seconds A�-IE1i�I 50326-00 stabilization time Maximum:268 seconds WIRING INSTALLATION GUIDELINESTESTING The detector must be tested after installation. The detector has two discrete All wiring must be installed in compliance with the NFPA 70 standards,Na test switches,one for smoke testing and one for CO testing.The detector may tional Electrical Code,applicable state and local codes. also be functionally tested using canned smoke and canned CO. The screw terminals in the mounting base will accept 14-22 gauge wire.Wire NOTE:Before testing,notifythe proper authorities to avoidanynuisance alarms. connections are made by stripping approximately 3/s"to 1h"of insulation from Ensure the proper wiring and power is applied to the detector.After power FIGURE 3:COSMO-2W WIRING DIAGRAM up,allow approximately 5 minutes for the detector to stabilize before testing. ALL CIRCUITS ARE SUPERVISED SMOKE O (EXCEPT TRIGGERS)AND MUST BE POWER LIMITED AUXPOWER O , (resectable) . �° ®O . Oma SMOKE O `� Panel 1., �� ZONE 0 Resistors -I-4' �A I r Ick �) kc.= , ) `� I 3.9k I r BI I '3'� RESISTOR I I If I VI ip,?vy ®� o I (supplied I ,} with module) CO 0 I I'! I ILII i I I I ZONE a I I I m�\ •O n I I I ` ,.. V-- ' o MAINT. Q – –At I I I I I I I COSMOD2W I I LOOPSTYLED/CL ASSA WIRING – ZONE O –Panel I COSMO-2W BELL n, Resistor I I OR I I J I- -I SMOKE I TRIGGER OUT 3 , CO I S0329-02 TRIGGER i L r OUT 2 I56-3747-003R 06-10 FIGURE 4:COSMO-4W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED SMOKE O (EXCEPT TRIGGERS)AND MUST BE POWER LIMITED POWER O r (resettable) O� _s, Q . � Ill ® Panel ° . L SMOK ,\ EOL E sea � o ZONE O 33 C' Resistors d --. �/ 0 1.N 10 nal 111'^ \. ' !;'' 3.9k RESISTOR CO 0 ( - - - 1 (' �. (supplied ZONE 0 • with module) 8 COSMOD4W COSMO-4W I I BELL n' I I OR I I j F SMOKE I 50330-00 TRIGGER OUT I r I COVI I TRIGGER , J OUT FIGURE 5:TEST BUTTON LOCATION AND OPERATION 3. If the detector is within the listed sensitivity limits,the sounder will alarm temporal 3 and the red alarm LED will light up. TEST BUSMOKETTON ce SMOKE SENSITIVITY READING -' To measure the detector's smoke sensitivity, the Infrared Sensitivity Reader ,>� • model#SENS-RDR should be used. lip, 4.it _� 1. Pointthe SENS-RDR directlyto the center of the detector at a distance of 1 to GAS PORTS '° 10 feet.A broomstick can be attached to the SENS-RDR for extended reach. �� 2. The sensitivity will be displayed on the SE NS-RDR.The SE NS-RDR will • t+ . also display"replace"if a detector is found faulty. �* SMOKE ENTRY TEST S0327-00 1. With the detector in standby mode,spray UL listed compatible,canned TEST BUTTON - CARBON MONOXIDE smoke into the detector. ' 2. When the detector senses the presence of the smoke,the sounder will TABLE 4:LEDINDICATION&SOUNDER DURINGTESTANDMAINTENANCE alarm temporal 3 and the red alarm LED will illuminate. GREEN BLUE Note:On some panels,resetting a smoke alarm may require additional steps LED RED LED LED SOUNDER at the keypad to clear the trouble conditions on CO and smoke mainte- nance zones due to power loss to the module. Smoke Maintenance OFF Blink 5 Sec. OFF OFF LOOP VERIFICATION(MODEL#COSMO.2W ONLY) CO Trouble/ OFF OFF Blink 5 Sec. Intermittent chirp Loop verification is provided by the EZ Walk loop test feature.This feature is End-of-Life after 30 days for use with compatible control panels and System Sensor 2-wire detectors (i4 Simultaneous Smoke Maintenance&CO Trouble/EOL Series model COSMO-2W and i3 Series model 2WTA-B)installed with the COS- MOD2W interface module only. The EZ Walk loop test verifies the initiating OFF Blink 5 Sec. Blink 5 Sec. OFF _ loop wiring and provides visual status indication at each detector: EZ Walk Test®-Normal 1. Ensureproper wiring and power is applied.Wait approximately 6 min- Double OFF OFF 01'1' utes after power-up before performing the EZ Walk test. Blink 5 Sec. 2. Place COSMOD2W interface module into EZ Walk test mode by depress- EZ Walk®-Smoke Maintenance ing the recessed test button on the COSMOD2W Interface Module. OFF Double OFF 3. Observe the LED's at each detector. Blink 5 Sec. NOTE:The EZ Walk loop test should not be used in lieu of functional testing EZ Walk®-CO Trouble/End-of-Life (alarm,trouble and other functional tests)of the system. Double CO TEST SWITCH OFF OFF slink 5 sec. Oil' 1. A recessed CO test switch is located on the detector housing and iden- tified by text that says"TEST"next to it and "CARBON MONOXIDE" EZ Walk®-Smoke Maintenance&CO Trouble/End-of-Life above it. (See Figure 5) OFF Double Double l 2. With the detector in standby mode,use a small screwdriver to press and re- 01 Blink 5 sec. Blink 5 sec. leasetheCO test switch.Pressingtheswitch onetimewill enter into RealTest® *NOTE:E ZWalk applies to COSMO-2W 2-wire model only. Mode(see instructions below),pressing two times will enter test mode. SMOKE TEST SWITCH 3. If the test is successful,the blue LED will light up.The detector and mod- 1. A recessed smoke test switch is located on the detector housing and ule will automatically reset within 60 seconds. identified by text that says"TEST"next to it and"SMOKE"above it.It is If the detector fails either of the above test methods the CO cell or the detector the switch closest to the red LED. (See Figure 5) should be replaced. 2. With the detector in standby mode,use a small screwdriver to press and release the smoke test switch. 3 I56-3747-003R 06-10 FUNCTIONAL GAS TEST 3. Remove the white cover of the screen/sensing chamber located in the Solo C6 brand canned CO may be used to verify the detector's ability to sense center of the detector head by turning counterclockwise. CO by utilizing the RealTest®feature as follows: 4. Remove the black screen/sensing chamber by pulling up on it. 1. Press and release the test switch onceas described in Testing above.The blue 5. Use canned air to remove any dust or particles that are present on both LED will start blinking rapidly indicating it is RealTest®mode.If the detector the chamber cover/screen and chamber itself. willnotgointoRealTest®mode,theCOsensoimaybeinfault or at end-of-life. 6. Replace the top half of the screen/sending chamber by aligning the two 2. While the blue LE Dis blinking,spray a small amount of canned CO di- arrows on the chamber cover with the notches in the detector head.Press rectly into the CO gas entry ports from 1/4"away. (See Figure 5) down until the screen/sensing chamber is fully seated. 3. The detector will go into alarm if the gas entry was successful and the 7. Replace the white cover by placing it over the screen/sensing chamber cell is functioning properly. and turning it clockwise until it snaps into place 4. The CO test will automatically clear when the CO clears or in 30 seconds 8. Reattach the detector head to the base by applying light pressure and if no CO was introduced. rotating clockwise.The detector will lock in place when properlyaligned. NOTE:Testing thedetector will activate thealarmandsenda signal to thepanel. 9. Test the detector to insure it is fully functional. (See Testing section) Carbon monoxide gas may be present in other areas. 10. Notify the proper authorities when the system is back in service. This detector is NOT: FIGURE 6:REMOVING/REPLACING SCREEN/SENSING CHAMBER • A substitute for the proper servicing of fuel-burning appliances or the sweeping of chimneys. • To be used on an intermittent basis,or as a portable alarm for the spill- age of combustion products from fuel-burning appliances or chimneys. y ,y MR_ti Carbon monoxide gas is a highly poisonous gas which is released when fuels are burnt.It is invisible,has no smell and is therefore impossible to detect with the human senses.Under normal conditions in a room where fuel burning ap- pliances are well maintained and correctly ventilated,the amount of carbon monoxide released into the room by appliances should not be dangerous. Do not paint,and do not use cleaning agents,bleach or polish the detector. SYMPTOMS OF CARBON MONOXIDE POISONING LIMITED LIFE OF CO SENSOR Carbonmonoxide bonds to thehemoglobin inthebloodandreduces the amount This detector is manufactured with a long-life carbon monoxide sensor.Over of oxygen being circulated in the body.The following symptoms are examples time the sensor will lose sensitivity,and will need to be replaced.A replace- taken from NFPA 720;they represent approximate values for healthy adults. ment CO sensor,model#CO-REPL,is available.The life span of the CO sensor Concentration(ppm CO) Symptoms is approximately six years from the date of manufacture. 200 Mild Headache after 2-3 hours of exposure Periodically check the detector's replacement date.Remove the detector head and refer to the sticker placed on the replaceable CO cell..The sticker will 400 Headache and nausea after 1-2 hours of exposure indicate the date the CO cell should be replaced. 800 Headache,nausea,anddizziness after 45 minutes of expo- Reminder:This detector is also equipped with a feature that will signal the sure;collapse andunconsciousness after 2 hoursof exposure panel once the CO sensor has passed the end of its'useful life.If Many cases of reported carbon monoxide poisoning indicate that while vic this occurs,it is time to replace the CO sensor. tims are aware that they do not feel well,they become so disoriented that they REPLACEMENT OF CO SENSOR are unable to save themselves by either exiting the building or calling for as- 1. Remove the detector head by turning counterclockwise. sistance.Also young children and pets may be the first to be affected. 2. Locate the CO sensor on the back side of the detector head. (Refer to Figure 7) CO ALARM ACTIVATION 3. Depress the 2 tabs on the CO sensor and pull it out. Per UL standard 2075,the i4series detector has been tested to the sensitivity 4. Insert replacement CO sensor model CO-REPL. limits defined in UL standard 2034. 5. Reattach the detector head to the base by applying light pressure and TABLE 6:CO ALARM THRESHOLDS rotating clockwise.The detector will lock in place when properlyaligned. Parts per Million(ppm) Detector Response Time(Min.) 6. Test the detector to insure it is fully functional. (See Testing section) 30+-3ppm No alarm within 30 days 7. Notify the proper authorities when the system is back in service. — NOTE:Before replacing the sensor or detector, notify the proper authorities 70+-5ppm 60-240 that maintenance is being performed and the system will be temporar- 150+-5ppm 10-50 ily out of service.Disable the zone or system undergoing maintenance 400+-10ppm 4-15 to prevent any unwanted alarms.Follow the proper testing protocol as outlined in the Testing section to make sure the device is functioning properly.Dispose of detector in accordance with any local regulations. What to do if the carbon monoxide detector goes into alarm: Immediately move to a spot where fresh air is available,preferably outdoors. FIGURE 7:CO SENSOR REPLACEMENT Find a phone in an area where the air is safe and call your security service provider.Tell your provider the detector alarm status, and that you require professional assistance in ridding your home of the carbon monoxide. -• f ` MAINTENANCE NOTE:Before performing any maintenance on the detector,notify the proper ', /` — authorities that maintenance is being performed and the system will IPc ® c9 I;�I® , be temporarily out of service.Disable the zone or system undergoing maintenance to prevent any unwanted alarmsPower must be removed from the detector before performing maintenance of any kind. ���,j CLEANING DI M�i/� 1_,� 1. Remove the detector head by turning counterclockwise. rl 2. Clean the outside casing with a cloth.Ensure that the holes on the front of the alarm are not blocked with dirt and dust.Canned air can be used REPLACEABLE CO CELL to remove any dust or debris. S0333-00 4 I56-3747-003R 02016 System Sensor.06-10 SYSTEM �$ SENSOR`°' SmokeDetectorswith 111 Sounder and RelayOption System Sensorir sounderand relaysmokedetectors applytheguidingprinciples of installation ease, 3 intelligence,and instantinspection in a seriesof mm specialty conventional devices. Features Installation ease.Throughout the i3 series,installation is simple •85 dB sounder with its installer-friendly base and p lug-in design.The base accommodates a broad range of back box and direct mounting •Form C relay options and provides ample sp aceforpre-wiring the device.To •Isolated thermal sensor complete the installation,the i3 detector p lugs into its base with a simp leStop-Drop'N Lockaction. •Plug-in design (base included) Intelligence.To reduce the likelihood of nuisance alarms,all •In-line terminals i3 detectors are equip p edwith both drift comp ensationand •Flexible mounting options smoothing algorithms.These capabilities minimize both short-and •Stop-Drop'N Lock'attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an P Ready'panel,2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or •Remote maintenance signaling freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift comp ensationand smoothing algorithms the SENS-RD Rdisp laysthe reading,in terms of percent-per-foot •Simplified sensitivity measurement obscuration,within seconds. •Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,i3 sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MODalso synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call fordifferentiating between a local and (120a general alarm,the i3 line offers an isolated thermal model,which ® c MEA MSFM ((Ei)1 initiates a local alarm when smoke is detected,and a general alarm LISTED �' approved approved Cus when the thermal sensor is activated. APPROVED II 3015195 7272-1653 164 372-02-E 2133 Cb Smoke DetectorSpecifications Electrical Specifications LED Modes OperatingVoltage Nominal:12/24V non-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5Vto35V Powerup Blink every Blinkeveryl0 Initial LED 80 seconds 4-wire:10 V to 35 V 10 seconds seconds status Maximum RippleVoltage 30%of applied voltage(p eakto peak) indication StandbyCurrent 2-wire:50 pA maximum average Normal Blinkevery5 off 4-wire:50 pA maximum average (standby) seconds PeakStandbyCurrent 2-wire:100 pA Out of off Blinkevery5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blinkeveryl0 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4 wire:4WTA B,4WTR B:35 mA Power-Ur6equencef or LED Indication 4WTAR-B,4WITAR-B:50 mA **DirectPower(Non-Reverse Polarity):130 Condition Duration mA limited by panel.Reverse PolarityPower: Initial LED 80 seconds 30 mA forthe 2WTA-Bin alarm;12 mA forall status other2WTA-Bunits on the loop.Add 25 mA indication forthe RRS-MODreversing relayalarm current. Architect/Engineer Specifications Alarm ContactRatings 2-wire:n/a Smoke detectorshall be a System Sensor i3 Series model number , 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 forFire Protection Signaling Form C ContactRatings 2 A @ 30V AC/DC Systems.The detectorshall be a combination photoelectric/thermal Physical Specifications equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2WTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated OperatingTemperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detectorshall include a Range mounting base formounting to 31/2-inch and 4-inch octagonal,single-gang, Operating H umidity 0 to 95%RH non-condensing and 4-inch square back boxes with a p lasterring,or directmountto the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.The detectorshall allow pre-wiring of the base and the FreezeTrouble 41°F(5°C) head shall be a plug-in typ eThe detectorshall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 p ercenlp erfootas measured in the UL smoke box.The detector InputTerminals 14 22 AWG shall be capable ofautomaticallyadjusting its sensitivityby means of drift compensation and smoothing algorithms.The detectorshall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction ApproximateWeight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need formaintenance at the alarm control p aneland and 4WITAR-B only) shall provide a loop testing cap abilityto verifythe circuitwithouttesting each Mounting 31/z inch octagonal back box,4 inch octagonal detectorindividually.When used in conjunction with the RRS-MODmodule, back box,single gang back box,4inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall backboxwith a p lasterring,directmountto be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information Model Thermal Wiring Alarm Current Model Description 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivityreader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofitadap terbracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA *--Th_ SYSTEM ©2009 System Sensor. 3825 Ohio Avenue•St.Charles, L 60174 Productspecifications subjecttochangewithoutnotice.Visitsystemsensor.com for )' SENSOR Phone:800-SENSOR2•Fax:630-377-6495 currentproduc(nformaton,includingthelatestversionofthisdatasheet. A05-0348-004.6/09.#2170 12/24VDC e'°" Carbon Monoxide0„ . : „,\ Detector with SafeTestT" - r D 260-CO 6`9� cc`° ce G i Overview Standard Features The SafeAirTM 260-CO carbon monoxide(CO)detector is an accu- • 10-year end-of-life signal rate and reliable means of alerting building occupants of potentially • SafeTest"feature — functional test with spray of real CO gas dangerous levels of CO in the protected area.The internal electro- chemical sensor communicates with a sophisticated on-board • Advanced electro-chemical sensingtechnology microprocessor that accurately tracks CO levels over time. • Wiring option activates soundersof all connected detectors This commercial-grade detection technology results in quick when any one of them goes into alarm response, reliable sensing,fast reset time,and superior false alarm • Deep hous ing with plenty of room for wiring immunity. Its s mall size allows the 260-CO to b lend inco ns p icu- ouslywith any decor, and its smoothcontoured design is compat- • UL 2075 compliant ible with both residential and commercial environments. • Transmits sensor end-of-life to the supervising panel and cen- Unaffected by normal indoor temperature variations,the 260-CO tral stationif the system is monitored automatically adjusts for environmental changes and operates • CO sensitivity conforms to UL 2034 requirements reliably under a wide variety of conditions.It alsomonitors its own • performance and compensates for sensitivity drift throughout the Built in trouble/power supervision relay courseof its service life. • Self-diagnostics keep the device operating optimally through- The 260-CO features the SafeTestT"'functional test feature,which out its service life facilitates testing with real CO gas.SafeTest meets the functional • 12 or 24VDC operation and 150mA Form C relay test requirement in NFPA 720, 2009/2012 editions. • Large SEMS terminals easewiring installation 14 to 22 AWG Like all CO detectors,the 260-CO has a limited service life.But • One-touch TEST/HUSH button simplifieslocal operation unlike most,which lastonly sixyears,the 260-CO's advanced sensor features a service life rated at 10 years.When it approach- • Integrated 85 dBa temporal-4 sounderfor local notification es this point,the 260-CO's end-of-life timer automatically triggers • On-board LED provides local alarm and trouble indication a warning that indicates the device must be serviced.This warning annunciates at the detector, as well as at the control panel,and • Inconspicuousfootprint and attractively contoured design optionally at a remote monitoring station. • Adapter plate simplifiesreplacing ESL 240-COe detectors An integrated temporal-4 sounderprovides local signaling capability forthe 260-CO,and it easily interfaces with any intrusion orfire alarm system by means of its output relay.Its low current draw results in little additional demand on the system powersupply. Page 1 of 4 DATA SHEE1 ESL85001-0632 interlogix.com Not to be used for installation purposes. Issue 1 Application ✓ Centrally located on every habitable level of the building and in every HVAC zone basedon an engineering evaluation con- The SafeAir 260 CO Carbon Monoxide Detector is intended for ordinary indoor-dwelling unit applications in both residential and s ideringpotential sources and migration of carbon monoxide commercial occupancies, including single/multiple family residential 1( On the ceiling in the sameroom as permanently installedfuel occupancies, hotel rooms,dorm rooms,and other areas approved burning appliances by the authority having jurisdiction(AHJ).The 260-CO detector ✓ In any area required by local building codes,legislation,or the can connect to either UL 985(Household Fire Warning)or UL 864 authority having jurisdiction (Commercial Fire)control panels. It is not intended for use in indus- 1/ On a firm, permanent surface trial applications s uchas gasoline refineries or parking garages, which require different listings. Do not install the CO detector: The 260-CO is a four-wire device that usesa Class 2 output from X Within 5 ft.(1.5 m)of any cooking appliance a control panel. Nonetheless,the primary alarm notification de- X Within 10 ft.(3 m)of a fuel-burning appliance vice remains the 260-CO's internal sounder with the control panel X Near air conditioners,heating registers,and any otherventilation secondary to these purposes.The 260-CO is not a substitute for life source that may interfere with CO gas entering the detector safety devices,and s ho uldbe only considered as an integral part of a comprehensive safety program. X Where furniture or draperies may obstruct the airflow X In a recessed area Selecting a suitablelocation is critical to the correct operation of CO detectors. Install the 260-CO in accordance with NFPA 720 Standard for the Installation of Carbon Monoxide(CO)Detection and Warning Equipment. Place wall-mounted detectors at least Operation 5 ft.(1.5 m) up from the floor. For ceiling mounted applications, SafeTest functional test:This testfacilitates the use of CO test place the detector at leas t1 ft.(0.3 m)from any wall. spray to verify the correct operation of the detector,which is man- Recommended CO detector locations: datory per NFPA 720.The SafeTest mode is activated by pressing ✓ Within 10 ft.(3 m)of all sleepingareas, including areas such and holding the test/hush button for 5-10 seconds.While in Saf- as hotel rooms and dorm rooms. eTest mode,directing UL-classified CO testingspray at the sensor 1( In a s uitab leenvironment: areas with a temperature range port will result in the activation of the alarm relay, and the sounder p g and red LED in a temporal-four pattern. Pressing and holding the of 40 to 100 °F(4.4 to 37.8°C)and with a relative humidity test/hush will exit SafeTest mode. range of 10 to 90%noncondensing. ✓ In residential dwellings,locate detectors in every bedroom Distinct temporal-four sounder alarm:The 85 dB temporal- and on each level.At a minimum, place one detector outside four sounderprovides a distinctive alarm notification that is easy the s Jeep ingareas. to differentiate from smoke alarm notification devices.The alarm beeps four times,rests five secondsand then repeats the pattern. Test/hush button:Usethe test/hush button to test the alarm and s ilencean activated alarm. Pushing the test/hush button silences - the integral sounderfor five minutes.The red alarm light stays on • p and if CO is still present after five minutes,the detector once again NM Ill 1 IIII if CO is the temporal four pattern. I il��II End of sensor life indicator:The detector usesboth a flashing ;� I� green LED and intermittent sounder chirps to indicate that the deI�_, ����i���, _ tector needs replacing.Tosilence the detector, pus hthe test/hush i1 i= O button.The detector alsobegins signaling a trouble when the CO 14! r� sensor is approaching end-of-life. 1 1 Common trouble relay:The trouble relay opens to indicate a trouble condition upon lostpower, CO sensor cell trouble, or cell 0 Recommended locations for CO detectors end-of-life.When connected to a listed control panel,the trouble Always checkwith your local building codes, relay can report a trouble condition locally at the panel and option- legislation,and Authority Having Jurisdiction ally at the central station, if the system is monitored. for specific CO location requirements in yourarea Recommended CO detectorlocations in commercial occupancies: WARNINGS:Connect the CO detector only to a zone dedicat ed exclusively for CO detection and that is monitored 24 hours ✓ Outs ideeach separate sleep ingarea in the immediate vicinity a day. Do not connect to an initiating circuit with fire or security of the bedrooms(including areas such as hotel rooms and devices. Failure to properly install,test,and maintain a CO dorm rooms) detector may causeit to fail,potentially resultingin lossof life. ✓ On every occupied level of a dwelling unit, including base- ments,but excluding attics and crawl spaces Page 2 of 4 DATA SHE t ESL85001-0632 Not to be used for in lation purposes. Issue 1 Installation The 260-CO/240-COe . The 260-CO Carbon Monoxide Detector is a four-wire device Udapte5 p lateEl Us ea 250-COPLT adaptor des igned to use a Clas s2 output from a control panel or auxiliary plate when replacing a 240- power supplyListed to UL 985 or 864 standards. COe with a 260-CO to cover --, All wiring must conform to the NFPA 70 National Electric Code,UL any paint discoloration left 2075, NFPA 720, and applicable codes.Use 14 to 22 AWG wire. behind. Wiring Single device, Multip ledevices, Multip ledevices, single zone single zone separate alarm,trouble zone EOL device EOL device EOL device gAMNC NC !MI I ■ _=, + + !MI I NC 1�\\]' NC \� /C1 110/C1 �I-\\ NO IA NO Alarm + - �� w c IDC Power �� NCC 0]"" NC +10 +1. —10 —1.1 Tandem Interconnect: Usea Single Circuit Reversal Module when wiring multiple 260-CO detectors for tandem i NCNC i c interconnect. On alarm,the NO NO module disconnects the detec- tor from its normal power supply and applies reverse polarity from r1 NC the notification appliance circuit. ` EOL device + EOL device -l'. This causes the s oundersto I I activate on other 260-CO detec- 9 9 9 9 9 9 9 tors that are on the same loop. z . e a s . e e Onlythe initiatingdetector will ESL 405 ESL 405 Polarity Reversal Polarity Reversal soundand blink red.All others Module Module in tandem mode will sound but 1 NC , e 6 , I;• NC not blink red. � ^� 6 9 9 9 9 is 9 9 9 9 }, I A NO i_0, NO 9 0 8 0 6 9i 0 8 9 8 Alarrm' Power NAC Alarm SUPV Power NAC IDC Control Panel IDC IDC Control Panel Page3of4 DATA SHEEESL85001-0632 Not to be used for in. Issuel Specifications Input voltage 12 or 24 VDC suppliecby UL 985 or UL 864 listed control panel or resettable auxiliary power supply Current consumption Normal 20 mA Alarm 40 mA(75 mA in test) Alarm relay 150 mA at 33 VDC Type Form C UL rating Zone Common trouble relay 150 mA at 33 VDC Type Normally opened held closedwith power applied UL rating Common Sens o rlife 10 years from date of manufacture Sounder 85 dB Compatible control panel Listed to UL 985 or 864 standards Compatible electrical box 2-1/2 in.(64 mm)single-gang Wire size 14 to 22 AWG(0.25 to 2.0 mm2) Dimensions(W x L x D) Detector 3.1 x 4.6 x 1.4 in.(7.8 x 11.7 x 3.6 cm) Adapter plate 4.5 x 6.5 x 0.2 in.(11.4 x 16.5 x 0.5 cm) Color White Operating environment Temperature 40 to 100 °F(4.4 to 37.8°C) Relative humidity 10 to 90%noncondens ing CO sensitivity 70 ppm,60 to 240 minutes 150 ppm, 10 to 50 minutes 400 ppm,4 to 15 minutes North America T 885-286-8889 Asia T852-2907-8108 Ordering Information F 852-2142-5063 Model Descrip tion Australia 260-CO SafeAir Carbon monoxide detector,alarm&trouble relays, T 61-3-9239-1200 sounder,end-of life s ignal,12/24VDC F 61-3-9239-1299 250-COPLT-5PKG Adaptor plate for use when replacing the 240-COe CO detector with a 260-CO Europe ESL 405-01 Polarity Reversal Module,24 VDC T 32-2-725-11-20 ESL 405-03 Polarity Reversal Module,12 VDC F 32-2-721-40-47 ESL 405-05 Polarity Reversal Module,12/24VDC Latin America CO Gas Test Spray Functional CO gas testspray Solo C-6 from SDI T 561-998-6114 (www.sdifire.com)available through security distribution. F 561-994-6572 interlogix interlogix.com Specifications subject to change w ithoutnotice. ©2012 Interlogix. Interlogix is part of UTC Climate Controls&Security, a unit of United Technologies Corporation. All rights reserved Page 4 of 4 DATA S H E L ESL85001-0632 rn Not to be used for in lation purposes. Issuel * SYSTEM �$ SENSOR' r •--T Mini-Horns The SpectrAlert Advance series ofmini-horn sounders are designed tosimplify installations toprovide primary and secondary signaling for fir ea n dsecurity applications. (+� (k) SPECTRIert A E V A IV C q r Features The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel,motel or residential fire system applications,where a • 12 and 24V operation smaller notification device is desired.The mini-horns offer high and • High and low volume settings low volume settings, and temporal or non-temporal tones. The horns • Temporal and non-temporal tones can be mounted to single gang back box esfor aesthetically sensitive • Mounts to single gang back box applications. Synchronization is also provided when using the MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-AlertTM sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories • Listing for ceiling or wall mounting Standard UL 464 for fire protective signaling systems. Agency Listings U L NvO ® '4,,,, 4.cr,, ,, LISTEDAPPROVED S4011 8028007 CS1099 7135-1653:196 SpectrAlert®Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Sync•Circuif°Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9"W x .45'D Weight 2.67 oz. OperatingTemperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/a"deep) Flush:Standard 4"x 4"back box with single gang mud ring,which allows sufficient clearance for conduit entrance. Electrical Specifications InputTerminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWRor regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White V, SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensor.com �_� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 forcurrent product information,including the latest version of this data sheet. AVDS01500.3/12