HomeMy WebLinkAboutE18-0063_Load Cal. Pates Res_1525196448.pdf °F I/4 ii:p0 NEC Standard Electrical Demand Load Calculation for Dwelling Unit Load Calculation Submitted by:Native Electrical,Inc. o Owner Name:Pates Residence Phone:970-328-3040 j'AM 11 Location:Edelweiss#404,103 Willow PI.Vail Total Sq.FT.:1200 05/01/18 Electrical Contractor:Native Electric,Inc. Name:Larry Arguello Phone No.for Electrical Contractor:(970)328-1293 Total VA Factor Descriptions Load Value Multiplier/Demand (Volt Amperes) General Lighting Load =Floor Area @ 3va/ft2(NEC 220.12) 3600 Main or Floor Area Second or 3rd Floor Area Basement Floor Area Small Appliance Load -@1500va for EA 20Amp Branch (NEC 220.52 (A)) 3000 Dishwasher (NEC 220.14) 1500 Microwave (NEC220.14) 1500 Range Hood (NEC 220.14) Refrigerator (NEC 220.14) 1500 Electrical Water Heater (NEC 220.14) Central A/C Unit(NEC 220.51) Baseboard Heater (NEC 220.52) Laundry Machine(NEC 220.52(B)) Garbage Disposal (NEC 220.53) 1500 Dryer (NEC 220.54) Oven Range (NEC 220.55) 7000 Bathroom GFI NEC 220.14) 1500 Calculations:21,100-10,000=11,000 x.40=4,440 15,540 15,540/240V= 64.75 64.75 Total Calculated Load in AMPS @120/240V Total Calculated Demend Load in VA Existing Service Size=100AMPS Minimum Service Size=100AMPS Service Size Required=100AMPS